Вы находитесь на странице: 1из 1

R1

PLAN SHOWING WEB REINF.(TOP) AT THE END

TYPICAL DETAIL OF LONGITUDINAL GIRDERS REINFORCEMENT SCHEDULE FOR


LONGITUDINAL GIRDERS
(SHOWING REINFORCEMENT ONLY)
BAR DIA OF BAR SPACING
NOT TO SCALE SHAPES REMARKS
MKD. (T) (Nos.)
BOTTOM
b1 32 7 NOS. MAIN BAR
BOTTOM
b2 32 7 NOS. MAIN BAR
BOTTOM
b3 32 3 NOS. MAIN BAR
b4 BOTTOM
32 2 NOS. MAIN BAR

b5 32 2 NOS. BOTTOM
MAIN BAR

b6 12 9 NOS. TOP BAR

b7 12 8 NOS. TOP BAR

SIDE FACE
b8 10 2X5 NOS. REINF.
SHEAR
b9 2L-12 150c/c. REINFORCEMENT
SHEAR
R1 b10 2L-12 150c/c. REINFORCEMENT
SHEAR
b11 2L-12 150c/c. REINFORCEMENT
SHEAR
b12 12 5 NOS. REINFORCEMENT
SHEAR
b13 12 150c/c. REINFORCEMENT
SHEAR
SECTION A-A SECTION B-B SECTION C-C SECTION D-D R1 b14 2L-16 150c/c. (L.V.) REINFORCEMENT
(MID SPAN) WEB REINF.
(SUPPORT) (3L/8) R1 b15 12 2X5 NOS. AT END EACH SIDE

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE
MENTIONED.ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
2. MESH REINF. SHALL BE PLACED AT 20mm ABOVE SOFFIT OF
GIRDER & 2ND LAYER SHALL BE PLACED AT 100mm
ABOVE SOFFIT OF GIRDER (SEE DETAILS BELOW)
3. i) GRADE OF CONCRETE IN DECK SLAB, LONGITUDINAL
GIRDER & CROSS GIRDERS SHALL BE M35.
GRADE OF CONCRETE IN CRASH BARRIER SHALL BE M40.
ii) GRADE OF REINFORCING BARS - Fe500D.
iii) MINIMUM CLEAR COVER TO ALL REINFORCING BARS
SHALL BE 50mm.
4. LAPS OF REINFORCEMENT:
i) MINIMUM ANCHORAGE LENGTH OF REINFORCEMENT
SHALL BE 36d,WHERE d IS THE DIAMETER OF THEBAR.
ii) MINIMUM LAP LENGTH OF REINFORCEMENT SHALL BE
54d, WHERE d IS THE DIAMETER OF THE BAR.
iii) NOT MORE THAN 50% OF REINFORCEMENT SHALL BE
LAPPED AT ANY LOCATION, UNLESS OTHERWISE
SHOWN.
DETAILS OF T8 MESH REINF. 5. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
AT BEARING LOCATIONS THE FOLLOWING DRG No :
2018001/RH/BR-KD/MJB-02/SUP-18
2018001/RH/BR-KD/MJB-02/SUP-20
OWNER : EPC CONTRACTOR : DESIGN CONSULTANT : R1 17.06.20 A Santra SS REVISED ASPER IIT COMMENT'S. DATE 03.05.19 DRAWING TITLE
R0 03.03.20 A Santra SS DRAWN A Santra REINFORCEMENT DETAILS OF PRECAST
M/S Ram Kripal Singh Construction Pvt. Ltd. REV DATE DRAWN CHECKED REVIEWED DETAILS OF REVISION CHECKED SS
RCC GIRDERS (24.30 m C/C. PIER ) FOR
MAJOR BRIDGE - 02 AT CH: 11+452.15
702, 7th Floor, Panchwati Plaza, Kutchery Road, APPROVAL FROM AUTHORITY APPROVAL OF THE PROOF REVIEWED OVER GOURI RIVER
Ranchi-834001,Jharkhand ENGINEER : CONSULTANT :
SHEET SIZE DRAWING No : 2018001/RH/BR-KD/ MJB-02/SUP-19 REV
PROJECT TITLE : FOUR LANING OF BARHI - KODERMA SECTION OF NH-31 FROM (KM 0.000 TO KM 27.500)
R1
IN THE STATE OF JHARKHAND UNDER NHDP PHASE IV. AUTHORISED SIGNATORY

Вам также может понравиться