GENERAL PLUMBING NOTES: LEGENDS: BRASS COVER

1. ALL PLUMBING WORKS HEREIN SHALL BE EXCUTED ACCORDING TO THE REQUIREMENTS OF THE PHILIPPINE
FLOOR SLAB
CWDF COLD WATER DOWNFEED
PLUMBING CODE & THE RULES & REGULATIONS OF THE LOCAL GOVERNMENT. CWLR COLD WATERLINE RISER

CWL COLD WATER LINE


2. COORDINATE THE DRAWING WITH THE OTHER RELATED DRAWINGS AND SPECIFICATIONS. THE ENGINEER
LAV LAVATORY
SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND HEREIN. WC WATER CLOSET
SH SHOWER / BATH TUB ( SECTION )
3. PIPES SHALL BE WITH THE PRIOR APPROVAL OF THE ARCHITECT AND THE ENGINEER. HB HOSE BIBB

KS KITCHEN SINK

4. THE PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION, DEPTH AND INVERT
COUNTER SUNK HEAD
KD KITCHEN DRAIN WITH BRASS SCREW
LF LAUNDRY FAUCET
PLUG AND COVER
ELEVATION OF THE EXISTING PIPES AND STRUCTURE AS VERIFIED BY THE CONTRACTOR.
LS LAUNDRY SINK
5. THE SLOPES FOR HORIZONTAL BRANCHES (SEWER) SHALL MAINTAIN 1% AS MINIMUM UNLESS AS NOTIFIED WP WATER PUMP

OTHERWISE.
( PLAN )
FCO FLOOR CLEAN OUT

CO CLEAN OUT
6. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE INDICATED. JB JUNCTION BOX

DS DOWNSPOUT
7. AIR CHAMBER: ALL INDIVIDUAL BRANCHES TO FIXTURE OR GROUP OF FIXTURES AND/OR EQUIPMENT SHALL
FD FLOOR DRAIN
BE PROVIDED WITH AIR CHAMBER CAPPED VERTICAL PIPE EXTENSION OF DIMENSION AS IN DETAIL.
SD SHOWER DRAIN 10 Kpa
BD BALCONY DRAIN
8. ALL SEWER LINES SHALL BE UPVC SERIES 1,000 BY "NELTEX", "ATLANTA" OR APPROVED EQUAL.
CONCRETE
THRUST
CB CATCH BASIN BLOCK

9. ALL VENT STACKS (VS) SHALL BE UPVC SERIES 1,000 BY "NELTEX", "ATLANTA" OR APPROVED EQUAL. DP DRAIN PIPE

SP/WP SOIL PIPE/WASTE PIPE


SECTIONAL ELEVATION
10. ALL CIRCUIT VENT (CV) SHALL BE UPVC SERIES 1,000 BY "NELTEX", "ATLANTA" OR APPROVED EQUAL. M WATER METER
( SECTION )
LD LAUNDRY DRAIN
11. ALL DOWNSPOUTS (DS) SHALL BE 2"Ø PVC TYPE SERIES 1,000 BY "NELTEX", "ATLANTA" OR APPROVED BRASS CLEANOUT FINISH
RD ROOF DRAIN GRADE LINE
EQUAL.
GV GATE VALVE
CONCRETE
12. ALL COLD WATER LINES SHALL BE 3/4"Ø (25mm) AND 1/2"Ø (20mm) PPR PIPES. CV CHECK VALVE BASE
10 Kpa
CAPPED CAPPED CONCRETE
THRUST
2.00 MTS. 1.20 MTS. BLOCK

INLET PIPE
100MMØ
( PLAN )
PRIMARY SETTING TANK LEACHING CHAMBER

TO FIXTURES TO FIXTURES

20mmØ CWL 15mmØ CWL


OUTLET PIPE
100MMØ
UE

(GOING TO SUMP PUMP


SITIO MACANHAN CARMEN
EN

TO GROUND FLOOR.)
AV
N
SO

1.50 MTS.

FROM SUPPLY FROM SUPPLY


ER

O
OR
ST
D
OA

MA

ER DE
R

RIV AN
SS

Y
PA

GA

SITE
BY

CA
SM

INLET PIPE
100MMØ

. AVE. DILG CONCRETE COVER


UE

PLAN
N. RO
A SR 4-12mmØ E.W.
AVEN

PEDRO
MANRESA
VER

RETREAT PVC PIPE


SM CITY
ON

CENTER
O RI

CDO
TERS

VIA
( SECTION )
E OR

GRAN
EXPANSION
MAS

SHIELD WITH FLAT BAR


D

BMW HOR. BARS=10mmØ 4-12mmØ E.W.


YAN

BOLT
.30 MT.

O
DE OR O 100MMØ VERTICAL
CAGA

PASE
( SECTION ) CONCRETE PIPE
OUTLET PIPE WALL/COLUMN
100MMØ
1.50 MTS.

(GOING TO SUMP PUMP


TO GROUND FLOOR.)
1.20 MTS.

PLAIN CEMENT PLASTER FIN.

DIGESTIVE CHAMBER LEACHING CHAMBER

P-1 VICINITY MAP


1 1:50MTS SCALE
( PLAN )
( PLAN )

SECTION
10mmØ AT .25 M.O.C.
BOTHWAYS

SECTION / ELEVATION
P-1 SEPTIC VAULT DETAIL
2 NTS SCALE

REPUBLIC ACT 9266


ARTICLE 4 SECTION 33, STIPULATES THAT ALL DRAWINGS AND
SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY
SIGNED, STAMPED ON SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY AREA
MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY
PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID
DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR
AUTHOR OF SAID DOCUMENT.