March 12, 2003

Art Montemayor Process Specification Sheets


Rev. 0

Specification Sheets Included in This WorkBook

1 Art's API 650 Storage Tank


2 Art's Centrifugal Pump
3 Art's Air-Cooled Exchanger
4 Art's Shell & Tube Exchanger
5 Art's Plate & Frame Heat Exchanger
6 Art's Process Vessel
7 Art's Control Valve
8 Art's Centrifugal Blower
9 Art's Orifice Meter
10 Art's Coriolis Meter
11 Art's Ultrasonic Meter
12 Art's Mass Meter
13 Art's Turbine Meter
14 Art's Vortex Meter
15 Art's Magnetic Meter
16 Art's …….

The accurate and complete preparation of Specification Sheets is one of the most (if not THE most)
important capabilities that a Chemical, Process, or Project Engineer should acquire very early in his/her
career.

An engineer is a problem solver, pure and simple. However, one cannot simply solve problems by
directly applying ones own efforts and time. In the industrial and competitive world, an engineer simply
does not have the time available to do all that must be done in order to resolve day-to-day problems.
That is why engineers are required to lead and supervise those around them in order to assure an
organized team-effort in resolving problems. To this end, engineers use communications skills (both
oral and written) as well as language, psychology, and interpersonal skills to inform and lead other
team members to a successful resolution.

At the very basic foundation of problem solving is the successful communications of the required
capital equipment required to resolve engineering problems. An engineer is unable to resolve a problem
if he/she is unable to successfully describe it in detail to the "stake holders" in a project. The ability to
receive constructive and cost-effective help and supply from parties involved in the project is directly
related to the timely and accurate description of the supply needed to resolve a problem.

Specification sheets are the indicated tools that are relied upon by engineers to convey an accurate
and detailed description of their needs and expected supply. These Specification sheets not only serve
to identify the required supply, they also serve to organize and structure the knowldege of the owner's
engineers as to the criticality and strategic importance of the supply. They force the Owner to comply
with the classic business rule: Emptor Caveat - buyer beware.

It is a basic business principle and law that the responsibility of defining the specific need for a supply
of goods or materials lies directly with the purchaser (or Owner). If you don't know what you need or don't
know how to describe what you need, you will never resolve your own problems. The Specification Sheet
describes to others not only what you identify as your specific needs, it also documents them and
communicates this information to all interested parties.

A large part of the problem in preparing accurate Spec Sheets is that the lead engineers (who often are the
most experienced and knowledgeable) are not the ones that prepare the Spec Sheets. It falls upon the
Process and Project engineers to prepare them and many times these individuals have to be trained and

FileName: 481378199.xls
Page 1 of 19
WorkSheet: Introduction
March 12, 2003
Art Montemayor Process Specification Sheets
Rev. 0
instructed on how to describe and specify equipment that they are only superficially familiar with. Therefore,
good Spec Sheets should be easy and simply to prepare, with a minimum of detail knowledge required.

I have arranged and organized the Spec Sheets found in this WorkBook in a manner that they should be
rather easy and intuitive for young engineers to prepare. A maximum use is made of drop-down list boxes
in order to facilitate the required information to engineers who are unaware of the various feature choices
available or much less how to describe them or spell them correctly. This method also "standardizes"
a variety of choices and does not leave it up to the individual to select whatever he/she thinks is required.
This method also allows the Spec Sheet to impose Corporate standards and pre-selected features without
wasting manpower to check their correct usage.

The utilization of an electronic spreadsheet such as Excel makes it easy for project documentation to be
safely stored, modified, and transmitted with a minimum of manpower. Engineers can generate and process
the documentation without further engineering assistance.

Additionally, the inherent calculation features of a spreadsheet are utilized to the maximum in allowing for
involved calculated information to be self-generated by the spreadsheet automatically. The spreadsheets
can be protected by the used/author for assurance that data will not be revised without prior knowledge.

The need to have calculations and related documentation readily available and filed due to legalities (such
as OSHA requirements on safety relief valve calculations and specifications) makes the spreadsheet a
natural tool for these requirements.

The utilization of Check boxes and Option buttons also give versatility and compactness to these Spec
Sheets, allowing the user to store more details and data in them. I have endeavored to limit the size of the
Spec Sheet to one page and design them around the need for communications of Process data for:

1. Documenting the results of calculations and other equipment details;

2. Preparing data and information for procurement inquiries (RFQs - Request of Quotes);

3. Obtaining Supplier information as related to a specific specification;

4. Preparing information that enters the Operations and Maintenance Manuals of a Unit;

5. Transmitting information regarding Unit equipment to other parties.

These Spec Sheets should be continuously revised and improved as spreadsheet technology improves or
is upgraded.

I will continue to work on and add additional Spec Sheets to this WorkBook in order to achieve as complete
a set of Spec Sheets as I can attain within the framework of available time.

FileName: 481378199.xls
Page 2 of 19
WorkSheet: Introduction
March 12, 2003
Art Montemayor Spec Sheet Log
Rev: 0

Index of Process/Mechanical Data Sheet and Specification Forms

Equipment Type go-by draft* complete* debugged issuable** accepted


Agitator, Mixer ü ü ü ü
Pressure Vessel ü ü ü
Tower, Column
Mist Eliminator ü
Fractionation Tray Data
Tower Packing Data
Storage Tank (API type) ü ü ü ü
Heat Exchanger, Tubular ü ü ü ü
Heat Exchanger, Plate & Frame ü ü ü
Heat Exchanger, Double-Pipe/Multi-tube
Process Equipment Specifications

Heat Exchanger, Air-cooled ü ü ü


Filter, Separator ü ü ü
Centrifuge
Pump, Centrifugal ü ü ü ü
Pump, Reciprocating/Metering ü
Pump, Rotary (Gear, Screw, Lobe, etc.) ü ü ü ü
Pump, Progressive Cavity
Compressor, Centrifugal ü
Compressor, Reciprocating ü
Compressor, Screw-type
Fan, Blower ü ü ü
Vacuum Pump
Vacuum Ejector System
Eductor, Mixing
Rotary Feeder Valve
Weigh-Feeder
Solids Blender
In-line Mixer

Electric Motor ü ü ü ü
Transformer ü ü
Auxiliaries, Other

Noise Compliance Data ü ü ü ü

* in Excel spreadsheet format ** write-protected

FileName: 481378199.xls
Page 3 of 19
WorkSheet: Spec Sheet Index 1
March 12, 2003
Art Montemayor Spec Sheet Log
Rev: 0

Index of Process/Mechanical Data Sheet and Specification Forms

Equipment Type go-by draft* complete* debugged issuable** accepted


Control Valves ü ü ü ü
Pressure Relief Valves
Orifice Plates
Instrument Specifications

Centrifugal Pump Calculation Sheet ü ü ü ü


PSV Selection Criteria ü ü ü ü
Data Sheets, Calculations (not specs.)

* in Excel spreadsheet format ** write-protected


STORAGE TANK SPECIFICATION Sheet 1 of 1
Montemayor, (English Units)
Inc. Project No. 1952.000

Rev. No.
1 Service : CRUDE OIL Storage Equipment No. : T-400 & T-405
2 Location : Galveston, Texas Unit : Kirwin Design Engineer : Art Montemayor
3 Manufacturer : Model : Mfr Ref. No. : No. Req'd : Two
4 P&ID No. PID115-EPF-01-112A1 Plot Plan No. : Other Ref. Dwg No. :
5
6
7
8
9 M
A P G
10
11
12
13 50.00 Ft
48" X 48"
H
14
FLUSH
15 32.00 Ft E CLEANOU
K E
16 T
17 L F D
18
19 N N
J I
20 1 2

21
22
23
24 Shell Diameter : 50.00 Feet Shell Height : 32.00 Feet Nominal Volume : 11,191 Barrels
25 Roof Type : Cone Bottom Floor Type: Sloped
26 OPERATING/DESIGN DATA NOZZLES/CONNECTIONS
27 Fluid Stored : CRUDE OIL Sp. Gr. : 0.7900 Mark Service Qty Size Rating Face
28 This Tank Service is considered: Cyclic A Roof Manway 2 24" 150# F. F.
29 Vapor Pressure @ Max. Operating Temperature 5.5 psia E Shell Manway 2 24" 125# R. F.
30 Flash Point (Closed Cup) : ºF Operating Design F Flush Cleanout MW 1 48"x48" 125# R. F.
31 Negative Pressure oz/in.2 0.00 0.50 G Stilling Vent 1 6" 125# F. F.
32 Positive Pressure psig 1.00 2.00 H Temperature Indicator 1 1" 150# L. J.
33 (Hydro)test Pressure expressed in Psig ---- I Outlet Nozzle 1 8" 150# API
34 Minimum Fluid Temperature ºF -25 J Fill Nozzle 1 10" 150# L. J.
35 Maximum Fluid Temperature ºF 200 K Mixer Manway 1 30" 150# F. F.
36 Emergency Vacuum Design ? Yes Set @ 0.0.3 oz/in.2 L Water Draw Nozzle 1 4" 150# R. F.
37 METALLURGY M Top Center Vent 1 8" 150# API
38 Component Material CA, in. Remarks N1 Sample Tap 1 3/4" 150# R. F.
39 Shell & Bottom 57370 0.1250 Normalized N2 Sample Tap 1 3/4" 150# F. F.
40 Roof 516 Grade 55 0.1250 Normalized P Roof Nozzle 1 4" 150# L. J.
41 Lining/Coating D Spare 1 2" 150# API
42 150# API
43 Stress Relieve ? Yes for: 150# API
44 CONSTRUCTION/FABRICATION
45 Code (as appl.): API 650 LATEST EDITION Internals (attach separate sheet, as req'd): Others:
46 Design Specifications: Sump
47 Tank Insulation ? No Thickness : in. Seismic Zone 3 Design Wind Velocity 100 mph
48 Insulation Type: Hot Radiograph 85 % Inspection Req'd ? Yes
49 Fireproofing ? Yes Paint Spec. EmptyTank Weight lb Full of Water lb
50 Remarks
51 1. Items marked with an asterisk (*) to be completed by Vendor/Fabricator.
52 2. Fixed cone roof with internal floating roof.

Approvals
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 For Inquiry
CENTRIFUGAL PUMP SPECIFICATION Sheet 1 of 1
M (English Units)
Project No. 1234567

Rev. No.
Montemayor Corporation
1 Service Crab Juice Transfer Pump Equipment No. P-37
2 Location Galveston, Texas Unit Balinese Room P.O. No.
3 Manufacturer * Model * Mfr Ref. No. * No. Req'd One
4 P&ID No. PID-01-0000 Plot Plan No. PLT-03-0000 Specification Engr: A. Montemayor
5 OPERATING CONDITIONS, EACH PUMP PERFORMANCE
6 Liquid Pumped Crab Juice Manufacturer's Proposal Curve No. *
7 Capacity @ PT, Normal 400 gpm Rated 500 gpm RPM * No. Stages * Hydr. Eff'y * %
8 Suction Pressure 14.7 psig (Norm.) 16.7 psig (Max.) Rated Brake Power * HP @ Max. Impeller * HP
9 Discharge Pressure 77.7 psig (Norm.) 90 psig (Max.) NPSH Req'd @ Impeller CL * ft @ TOC * ft
10 Differential Pressure 63.0 psi Diff. Head (TDH) 170 ft Min. Flow Req'd * gpm Cont. Thermal
11 Temperature, Normal 120 ºF Max. 190 ºF Suction Specific Speed * fps
12 Specific Gravity 0.854 @ PT 0.839 @ Max. Temp. Rotation (viewed from Cplg end) CW CCW
13 Vapor Press. @ PT 6.87 psia NPSH Available 14 ft SITE CONDITIONS
14 Viscosity @ PT cP cSt SSU Location Indoors X Outdoors Elev. 97 ft ASL
15 Corrosion/Erosion Caused By: Ambient Temp. 100 ºF Max. 10 ºF Min.
16 Solids Present Concentration % CW Supply psig @ ºF Max.
17 Size Distribution CW Return psig, Min. @ ºF Max.
18 Liquid is Flammable Toxic Other: Electrical Power 220/440 v 3 Ph 60 Hz
19 Contains Chlorides H2 S Other: Area Classification: Class II Div. A Group 1
20 CONSTRUCTION
21 Nozzles Size Rating Facing Location Materials
22 Suction 1½" 150# FF Case/Trim (API Class)
23 Discharge 3" 150# RF Casing Corr. Allow. in.
24 Int'l Ctg/Lining Gland
25 Case Mount'g CL Foot Brckt Vert. (Type) Impeller Wear Rings
26 Split Axial Radial Volute Single Radial Diffuser Shaft Sleeve(s)
27 Case MAWP * psig @ * ºF Hydrotest @ * psig Baseplate Drip Pan
28 Connections Vent Drain Gauge Steam Jkt Epoxy Grout, etc.
29 Impeller Open Closed Special Internal Wear Parts
30 Diameter: Rated * in. Max. * in. Min. * in. Wear Rings Case Impeller
31 Mount Betw. Brgs. Overhung Type Diameter * in.; Clearance * in.
32 Bearings Radial Thrust Int'stge Bush'gs, Diam. * in.; Cl'rnce * in.
33 Lube Ring Oil Flood Oil Mist Flinger Pressure Weights and Dimensions
34 Cplg. Mfr Model Approx. Wt., Pump & Base * lb
35 Driver Half Mounted By Pump Mfr Driver Mfr Motor Wt. * lb Turbine Wt. lb
36 Seal Mech. Packing Auxiliary Mech. Packing Baseplate Dimensions (in.) *
37 Seal Mfr. Type Model Baseplate No. * ANSI API
38 Mfr Code API Code Applicable Specifications
39 Jacketed Box Other API 610
40 Gland Tap Quench Drain Flush Vent ANSI B73.1 B73.2
41 Auxiliary Piping Huntsman Spec.
42 CW Plan Total CW Req'd gpm Sight FI
43 CW Piping Mat'ls Cu SS CS Tubing Pipe Inspection and Tests
44 Packing Cooling Injection gpm @ psig Shop Inspection Req'd
45 Seal Flush Plan SS CS Tubing Pipe Hydrostatic Test Req'd Witness
46 SF Fluid gpm @ psig Box psig Performance Test Req'd Witness
47 Auxiliary Seal Plan SS CS Tubing Pipe NPSH Test Req'd Witness
48 Auxiliary Seal Flush/Quench Fluid Internal Insp'n After Test Req'd Witness
49 Seal Flush Piping Threaded Socket Weld Flanged Other: Req'd Witness
50 Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
51 2. See Motor Data, Sheet 2 of 2.
52
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 9-Oct-02 For Inquiry ABC DEF XYZ
AIR-COOLED EXCHANGER SPECIFICATION Sheet 1 of 1
Montemayor (English Units)
Corporation Project No. 1234567

Rev. No.
1 Service Process Vapor Condenser Equipment No.
2 Location Cedar Rapids, Iowa Unit Furfural P.O. No.
3 Manufacturer * Model * Mfr Ref. No. * No. Req'd One
4 Size Type Draft Type: Forced No. of Bays
5 Heat Duty 100,000,000 Btu/h Effective MTD 150 ºF Surface/Unit, Finned ft2; Bare Tube ft2
6 Transfer Rate, Ext'd Surface : 250 Btu/ft ·h·ºF Bare Tube - Service :
2
Btu/ft ·h·ºF Clean :
2
Btu/ft ·h·ºF
2

7 P&ID No. Plot Plan No. Other Ref. Dwg No.


8 PERFORMANCE DATA - TUBE SIDE
9 Fluid Name Lethal Service? No Inlet Outlet
10 Total Fluid Entering lb/h Specific Heat, Liquid Btu/lb·ºF
11 In Out Specific Heat, Vapor Btu/lb·ºF
12 Temperature ºF Thermal Cond., Liq. Btu/ft·h·ºF
13 Vapor lb/h Thermal Cond., Vap. Btu/ft·h·ºF
14 Mol. Wt. Viscosity, Liquid cP
15 Liquid lb/h Viscosity, Vapor cP
16 Non-Condensables lb/h Latent Heat Btu/lb
17 Mol. Wt. Pour/Freeze Point ºF
18 Steam lb/h Dew/Bubble Point ºF
19 Water lb/h Operating Pressure, Inlet psig
20 Fluid Vaporized or Condensed lb/h Velocity X Max. Min. fps
21 Steam Condensed lb/h DP, Clean (Allow./Calc.) psi
22 Liquid Specific Gravity Min. Fouling Resistance ft2·h·ºF/Btu
23 PERFORMANCE DATA - AIR SIDE
24 Air Quantity, Total lb/h scfm Plant Altitude ft Above Sea Level
25 Air Quantity per Fan lb/h scfm Temperature In (Design Dry Bulb) ºF
26 Velocity X Max. Min. Temperature Out ºF
27 Face Velocity std fps Mass Velocity (Net Free Area) lb/h·ft2 Min. Design Ambient Temp. ºF
28 CONSTRUCTION AND MATERIALS
29 Design Pressure psig Test Pressure psig Design Temperature ºF
30 Section Header Tubes
31 Size Type Material : 316 Stainless Steel
32 No. per Bay Tube Rows Material 316 Stainless Steel Fabrication Type : Seamless
33 Arrangement: Two No. of Passes Slope in./ft OD 1-1/2" in. Gage, B.W.G. : 18
34 Bundles in Series Parallel Plug Material No./Bundle : 50 Length : 40 ft
35 Bays in Series Parallel Gasket Material Pitch : 1.25 in. Pattern Rot. Square
36 Bundle Frame: Corrosion Allowance in. Tube Sheet Joint : Welded
37 Miscellaneous Connections No. Size Rating Facing Fins
38 Structural Mounting Inlet Type : Low-Finned
39 Outlet Material :
40 Surface Preparation Temperature OD in. Stock Thk. in.
41 Louvers Auto Manual Pressure Fins/inch Des. Temp. ºF
42 Code Requirements: ASME Sec. VIII, Para. 1 (1992)
43 MECHANICAL EQUIPMENT
44 Fan Driver Speed Reducer
45 Mfr/Model No. Type Type : Gear box
46 No./Bay HP/Fan Mfr/Model No. Mfr/Model No.
47 Diameter ft Pitch Angle No./Bay No./Bay
48 Blade Mat'l RPM HP/Driver RPM AGMA Rating HP
49 Tip Speed fps Enclosure Ratio :
50 Pitch Adj. % Auto-Variable % Power v Ph Hz Support : Structure
51 Steam Coil? Yes No Air Recirculation Control : External - Over Side
52 Air Failure Control Action: Fan Pitch Min. Max. Lockup Louvers Open Close Lockup
53 Vibration Switches Req'd? Yes No Chemical Cleaning, etc.
54 Plot Area * Weight - Bundle * lb Shipping Weight * lb
55 Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
56
57
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 27-Nov-02 For Inquiry ABC DEF XYZ
SHELL & TUBE HEAT EXCHANGER SPECIFICATION Sheet 1 of 1
Montemayor (English Units)
Corporation Project No.

Rev. No.
1 Service Lean MEA Solution Cooler Equipment No.
2 Location Km 8, Avda. Venezuela; Lima, Peru Unit German Huanuco P.O. No.
3 Manufacturer * Model * Mfr Ref. No. * No. Req'd
4 TEMA Size, Type Horiz. Vert. Connected in Series Parallel
5 Surface/Unit * ft
2
Gross Eff. Shells/Unit One Surface/Shell * ft
2
Gross Eff.
6 P&ID No. Plot Plan No. Other Ref. Dwg No.
7 PERFORMANCE OF ONE UNIT
8 Fluid Allocation SHELL SIDE TUBE SIDE
9 Fluid Circulated
10 Total Fluid Entering lb/h
11 Vapor (In/Out) lb/h
12 Liquid lb/h
13 Steam lb/h
14 Non-Condensables lb/h
15 Fluid Vaporized or Condensed lb/h
16 Steam Condensed lb/h
17 Temperature ºF
18 Density, Specific Gravity
19 Viscosity cP
20 Vapor Molecular Weight
21 Specific Heat Btu/lb·ºF
22 Thermal Conductivity Btu/h·ft·ºF
23 Latent Heat Btu/lb
24 Operating Pressure, Inlet psig
25 Velocity Max. Min. fps
26 Pressure Drop, Clean (Allow./Calc.) psi
27 Fouling Resistance ft2·h·ºF/Btu .
28 Heat Exchanged Btu/h
Log MTD (Uncorrected) ºF Log MTD (Corrected) * ºF
29 Transfer Rate, Service *Btu/ft2·h·ºF . Transfer Rate, Clean * Btu/ft2·h·ºF .
30 CONSTRUCTION AND MATERIALS
31 SHELL SIDE TUBE SIDE Sketch (Bundle, Nozzle Orientation)
32 Design Pressure psig
33 Test Pressure psig
34 Design Temperature ºF
35 Number of Passes per Shell
36 In
37 Connections Out
Size & Rating
38 Intermediate
39 Tubes: Type Number * OD 0.75 in. 16 BWG or 30° in.
45°
X Min.60° 90°
Av. Wall
40 Tube Length in. Tube Pitch 0.9375 in. Flow Pattern (circle one)
41 Shell: ID * in. OD * in. Tube-to-Tubesheet Joint Rolled and welded
42 Baffles - Cross: Type * Spacing * in. * % Cut on X Diam. Area
43 Baffles - Long: Perm. Removable Seal Type: Bypass Seal:
44 rv2: Inlet Nozzle * lb/ft·sec Bundle Entrance * lb/ft·sec Bundle Exit * lb/ft·sec
45 Expansion Joint? Yes X No Type: Impingement Protection? X Yes No
46 PART MATERIAL§ THK, in. C.A., in. PART MATERIAL§ THK, in. C.A., in.
47 Tubes 16 BWG min. Floating Tubesheet * ----
48 Shell * Fixed Tubesheet * 0.125
49 Shell Cover * Tube Supports * 0.125
50 Channel * Cross Baffles * 0.125
51 Channel Cover * Long Baffle * 0.125
52 Fltg Head Cover * Gaskets ----
53 §
Stress Relieved (Mark "SR') and/or Radiographed (Mark 'XR') Parts User Spec.:
54 Code Requirements: ASME Sec. VIII, Para. 1 (1992) Stamp? X Yes No TEMA Class:
55 Weights: Shell * lb Filled with Water * lb Bundle * lb
56 Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
57
58
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 For Purchase
PLATE & FRAME HEAT EXCHANGER SPECIFICATION Sheet 1 of 1
Montemayor (English Units)
Corporation 1234567

Rev. No.
Project No.

1 Service Cooling Water Exchanger Equipment No.


2 Location Barbados, West Indies Unit Tuffy Forbes P.O. No.
3 Manufacturer * Model * Mfr Ref. No. * No. Req'd One
4 Size, Type *-* Frames/Unit One Connected in Single
5 Surface/Unit * ft2 Effective Surface/Frame * ft2 Gross
6 P&ID No. Plot Plan No. Other Ref. Dwg No.
7 PERFORMANCE OF ONE UNIT
8 Fluid Allocation HOT SIDE COLD SIDE
9 Fluid Circulated Cooling Water
10 Total Fluid Entering lb/h 31,500 206,483
11 Vapor (In/Out) lb/h ---- ---- ---- ----
12 Liquid lb/h 31,500 31,500 206,483 206,483
13 Steam lb/h ---- ---- ---- ----
14 Non-Condensables lb/h ---- ---- ---- ----
15 Fluid Vaporized or Condensed lb/h ---- ---- ---- ----
16 Steam Condensed lb/h ---- ---- ---- ----
17 Temperature ºF 235 120 90 105
18 Density, Specific Gravity 0.907 0.929 0.995 0.992
19 Viscosity cP 0.54 13.7 0.76 0.65
20 Vapor Molecular Weight ---- ---- ---- ----
21 Specific Heat Btu/lb·ºF 0.867 0.843 1.0 1.0
22 Thermal Conductivity Btu/h·ft·ºF 0.178 0.160 0.358 0.365
23 Latent Heat Btu/lb ---- ----
24 Operating Pressure, Inlet psig 75 60
25 Velocity X Max. Min. fps 8.0 8.0
26 Pressure Drop, Clean (Allow./Calc.) psi 10 * 10 *
27 Fouling Resistance ft2·h·ºF/Btu 0.001 0.003
28 Heat Exchanged 3,097,238 Btu/h Log MTD (Uncorrected) 157.0 ºF Log MTD (Corrected) * ºF
29 Transfer Rate, Service * Btu/ft2·h·ºF Transfer Rate, Clean * Btu/ft2·h·ºF
30 CONSTRUCTION AND MATERIALS
31 Allocation HOT SIDE COLD SIDE Sketch (Frame, Nozzle Orientation)
32 Design Pressure psig 150 125
33 Test Pressure psig Code Code
34 Design Temperature ºF 300 300
35 Number of Passes per Frame Two *
36 Corrosion Allowance in. 0.0625 None
37 In 3" 150# RF 6" 125# FF
Connections
38
Size & Rating
Out 3" 150# RF 6" 125# FF
39 Intermediate ---- ----
40 rv2, Inlet/Outlet lb/ft·s
41 Impingement Protection? Yes
42 No. of Plates Frame Capacity (Max. No. of Plates)
43 PART MATERIAL§ THK, in. C.A., in. PART MATERIAL§ THK, in. C.A., in.
44 Plates Stnless Steel 16 BWG min. 0.03125 Connections Stnless Steel 0.03125
45 Plate Gaskets Carbon Steel * 0.03125 Frame Carbon Steel 0.03125
46 End Cover Carbon Steel * 0.03125 Carrying Bar Carbon Steel 0.03125
47 Carbon Steel 0.03125 Carbon Steel 0.03125
48 § Stress Relieved (Mark "SR') and/or Radiographed (Mark 'XR') Parts
49 OSHA Type Protective Shroud? Yes Material: Carbon Steel Insulation: Heat Conservation
50 Cleaning: Painting:
51 Code Requirements: ASME Sec. VIII, Para. 1 (1992) Stamp? Yes
52 Client Spec.: Weights: Empty Frame * lb Filled with Water * lb
53 Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
54
55
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 30-Sep-00 For Inquiry ABC DEF XYZ
PROCESS VESSEL SPECIFICATION Sheet 1 of 1
Montemayor (English Units)

Rev. No.
Corporation Project No.
1 Service: Filter Feed Tank Equipment No. V - 41
2 Site: Belle Glade, Florida Unit Furfural P.O. No.
3 Manufacturer: * Model: * Mfr Ref. No. * No. Req'd One
4 P&ID No. PID-01-2084 Plot Plan No. PLT-03-2049 Other Ref. Dwg No. Note 2
5 PROCESS (OPERATING) DATA VESSEL SKETCH
6 Position Horizontal X Vertical Top Bottom
7 Shell Diameter ID X OD ft-in. 8'-0" 8'-0"
8 Shell Length TL-TL X S-S ft-in. 9'-6" 9'-6"
Q
9 Internal Pressure psig 0 0 P
B D
O F
10 Temperature (Min/Norm/Max) ºF Amb. Amb. A C E
H
11 Nominal Volume 3,000 gal Total Volume 4,900 gal
K
12 Fluid Contained: Specific Gravity 1.0 Note 4
13 Vapor Pressure @ Max. Ambient Temperature 0.95 psia
14 Process Contaminants L
Baffle
15 Service is X Cyclic Lethal Other (4 req'd)
16 METALLURGY
8'-0" OD
17 Component Material CA, in. Remarks

Dip Tube (2 req'd,


Nozzles 'A' & 'B')
9'-6" S-S
18 Shell & Heads 304SS None
19 Internals X Welded 304SS None Baffles, Dip Tubes,
20 Remov. Vortex Breaker G
21 Supports CS None
22 J

23 MECHANICAL DESIGN
24 Des. Press. @ Top 5 psig Ext. Des. Press.N/A psig

4 Legs (min.)
25 System PSV Set @ psig; located @ top of vessel 1 M
6'-11 "
½ 1
26 Des. Temperature 100 ºF Minimum Temp. -20 ºF
27 Vessel Support(s) Skirt X Legs Lugs Saddles
28 Height (Btm of Horiz. or BTL of Vert.) ft Above Grade Vortex Breaker
N
29 Fireproofing Other
30 X Insulation X H C PP Thickness in.
31 Design Codes: ASME Section VIII (1992); no stamp req'd
32 Post-Weld Heat Treatment for:
33 X Radiograph 85 % Inspection Req'd? X Yes No
34 NOZZLES/CONNECTIONS
35 Mark Service Qty Size Rating Facing
36 A Liquid Inlet w/Dip Tube 1 2" 150 lb RF
37 B Liquid Inlet w/Dip Tube 1 1½" 300 lb LJ
38 C N2 Pad 1 1½" 300 lb RF
39 D Vent 1 1½" 300 lb RF
40 E Fill Connection (Note 4) 1 1½" 300 lb RF
41 F Agit'r Opn'g w/Reinf. Pad (Note 3) 1 1½" 300 lb RF Specify Operating Levels Above Btm or BTL
42 G Manhole w/Davit 1 1½" 300 lb RF
43 H Relief Valve 1 6" 300 lb RF LCH Standard Displacer
Ranges are:
44 J Level Indicator (DP Cell) 1 2" 300 lb LJ HLL
14"
45 K Level Indicator (Equal. Conn.) 1 2" 300 lb RF LAH 24"
46 L Liquid Inlet 1 4" 300 lb LJ NLL 32"
45"
47 M Temp. Indicator 1 1" 300 lb RF LAL Special Design
48 N Pump Suction 1 3" 300 lb RF LLL Over 45"
49 O Light (Future) 1 3" 300 lb RF LCL
50 P Sight Glass (Future) 1 4" 300 lb RF
51 Q Spare 1 4" 300 lb RF Weights: Vessel Only * lb Internals * lb
52 1" 300 lb RF Operating Weight lb Full of Water * lb
53 Remarks: 1. Items marked with an asterisk (*) to be completed by Vendor.
54 2. Ref. set of detail dwgs for existing V - 41 (circa 1969). 3. Agitator supplied by Owner; conn. details on ref. dwgs.
55 4. Nozzle 'E': Tube Turn 12" T-Bolt hinged closure.
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 21-Aug-98 For Inquiry ArtM DEF XYZ
INSTRUMENT SPECIFICATION - CONTROL VALVES Sheet 1 of 1
M (English Units)

Rev. No.
Montemayor Corporation Project No. 1937
1 Location Perros Bravos, Nuevo Leon Tequila Conmemorativa
Unit P.O. No. Estimate Inquiry
2 Tag Number PCV G 1st PCV G 2nd
3 P&ID Number F-01-2411 F-01-2411
4 Line Number 2" 300AA-5238-457 1" 1500AA-5238-460
5 Assoc. Equip./Service C - G - 02 & C - G - 03 C - G - 02 & C - G - 03
6 SERVICE CONDITIONS
7 Fluid Name Phase(s) Flow Units Recycle Gas 2-Ph SCFM Recycle Gas Vap SCFM Liq gpm
8 Temp., Min. Operating Max. oF 150 290 350 150 180 350
9 Liq. SG @ 60 oF SG @ Op. T Vapor MW N.A. 4.268 N.A. 4.268
10 Critical Press., PC Op'g Viscosity, m N.A. psia 0.013 cP N.A. psia 0.012 cP psia cP
11 Flow, Min. Norm. Max. Capacity 200 265 350 350 200 265 350 350
12 Upstream Pressure @ Flow psig 500 500 500 500 1,000 1,000 1,000 1,000
13 Downstream Pressure @ Flow psig 495 495 495 495 995 995 995 995
14 Fluid Density at Inlet T&P, Flow lb/ft3 0.2708 0.6082
15 Valve CV @ Flow (Calculated)
16 Maximum Closed DP Fail Position 7 psi Closed 7.0 psi Closed psi Open
17 VALVE SELECTION, FLOW CHARACTERISTICS
18 Manufacturer Model Valtek Valtek
19 Trim Characteristic Flow Direction Linear Under Equal % Under Mod. Parabolic Over
20 Bal./Unbal. Body Size Port Size Unbal. in. in. Bal. in. in. Bal. in. in.
21 Trim Size Stroke in. in. in. in. in. in.
22 Valve Percent Open 25% 50% 90% 100%
23 Actual CV @ % Open
24 End Connections (Size, Rating, Facing) 2" 300# RF 1½" 1500# RF 1" 150# Ring-joint
25 Bonnet Type Number of Ports Extended Two Standard Two Cooling Fin Four
26 Lube & Isolating Valve (check) Lube
27 Packing Type Packing Material Molded V-Ring Graphite Impreg. Molded V-Ring Graphite Impreg. Braided Graphite
28 MATERIALS
29 Bonnet/Body Liner 316ss 316ss
30 Plug/Ball/Disk Seat/Seat Ring 316ss 316ss
31 Cage/Guide Stem
32 ACTUATOR
33 Type Diaphragm, pneumatic Diaphragm, pneumatic Hydraulic Piston
34 Manufacturer Model
35 Size Eff. Area, in.2 Service Modulating Modulating On-off
Date
###

36 Spring Action Handwheel Pos., Orient. Open Top, Left-hand Close Top, Right-hand Open Side, Left-hand
37 Max. Allow. Press. Min. Req'd Press. psig psig psig psig psig psig
38 Avail. Air Supply Press., Max. Min. psig psig psig psig psig psig
Rev.
###

39 Travel starts @ Rated Travel @ psig psig psig psig psig psig
40 POSITIONER
41 Type Single-acting Double-acting None
42 Manufacturer Model
Instrument Form No
Automatic Valve

43 Signal incr. … output to Actuator Cam Increases Linear Decreases Square Root Increases Square Root
44 Check Other ✘ Gauges By-pass Gauges ✘ By-pass ✘ Gauges By-pass
45 SWITCHES
46 Type Quantity Proximity Mechanical Pneumatic
47 Manufacturer Model
48 Contacts/Rating Actuation Points
49 AIR SET
50 Manufacturer Model
51 Set Press. Other (check) psig Filter Gauge psig Filter Gauge psig Filter Gauge
52 SPECIALS/ACCESSORIES/TESTS
53 Electrical Area Classification (if appl.) Class I Group A Div. 1 Class II Group C Div. 1 Class III Group B Div. 2
54 Hydro Pressure ANSI/FCI Leak Class psig Class I psig Class II psig Class III
55 Other
56 Remarks The Recycle Gas working fluid is a binary mixture of 15% vol NH3 + 85% vol H2 (60 % wt NH3 + 40 % wt H2)
57 Two control valves are required for each of the two services.
58

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
CENTRIFUGAL FAN, BLOWER SPECIFICATION Sheet 1 of 2
Montemayor (English Units)
Corporation Project No. 1234567

Rev. No.
1 Service Political Hot Air Equipment No. CF - 100
2 Location Kingston, Jamaica Unit Alf Newton P.O. No.
3 Manufacturer * Model * Mfr Ref. No. * No. Req'd One
4 P&ID No. PID-01-0000 Plot Plan No. PLT-03-0000 Other Ref. Dwg No.
5 OPERATING CONDITIONS PERFORMANCE
6 Gas Handled : Manufacturer's Proposal Curve No.
7 Service is Continuous Intermittent for hrs/day Type Centrifugal Axial Vane
8 Capacity, Normal lb/h or SCFM RPM 3600 No. Stages 1 Efficiency %
9 Capacity, Design lb/h or SCFM Inlet Size/Rating Top Bottom Side
10 Inlet Pressure in. WC Inlet Temp. ºF Disch. Size/Rating Top Bottom Side
11 Disch. Pressure in. WC Disch. Temp. ºF Case Design Press. psig; Design Temp. ºF
12 Gas Mol. Wt. Compr. (Z) at Inlet Relief Valve No. Located @
13 Cp/Cv at Inlet By Mfr By Customer Set @
14 Corrosion/Erosion Caused By Rotation (viewed from Cplg end) CW CCW
15 Dust Present? No Yes ; Name Packing, Type: No. of Rings
16 Concentration gr/ft3 Size Range m Mech. Seal, Type: Mfr by
17 Solids are Abrasive Explosive Sticky
18 Other (specify) Driver
19 SITE CONDITIONS Type: Mfr to Furnish Mount
20 Location Indoors x Outdoors Elev. 97 ft ASL Direct Indirect: V-Belt Gear
21 Ambient Temp. ºF Max. ºF Min. Single Variable Speed HP RPM
22 Max. Relative Humidity Other v Ph Hz Enclosure
23 Electrical Area Classification NEMA Service Factor
24
25 MECHANICAL DETAILS AND MATERIALS OF CONSTRUCTION
26 Case Rotor(s) Shaft Bearings Gears V-Belt Drive
27 Cast Iron Aluminum Steel Ball Steel V-Belt
28 Steel Alloy Steel 316SS Sleeve Static Conductor
29 Aluminum Cast Steel Roller Guard
30 316SS 316SS Sparkproof
31
32 Coupling(s) Bearing Lubrication Shaft Sleeve Lantern Ring Packing Gland Water Cooling
33 Flexible Oil Stellited Bronze Bronze Seal
34 Fast/Falk Grease 420SS Cast Iron Cast Iron Bearing
35 Guard None Steel Steel None
36 Sparkproof None
37
38 Common Baseplate and Driver by Mfr? Yes No Baseplate Mat'l Cast Iron Fabricated Steel
39 Baseplate Dimensions Approx. Wt., Blower & Base lb Driver Wt. lb
40 PROCESS CONTROL SKETCH (Incl. Scope of Supply
41
42
43
44
45
46
47
48
49
50
51
52
Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
0 27-Dec-96 For Inquiry ABC DEF XYZ
FLOWMETER SPECIFICATION, ORIFICE PLATE Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location El Gallinero, Nuevo Leon Unit Huevos Rancios P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Service or Associated Equipment


6 SERVICE CONDITIONS
7 Fluid Name and Phase (l, v, g or 2Ø)
8 Flow, Min. Nominal Max. units
9 Temp., Min. Nominal Max. ºF ºF ºF
10 Press., Min. Nominal Max. psig psig psig
11 Mol. Wt. CP/CV Compress. Factor
12 Fluid Density @ STP @ Op'g T&P
13 Viscosity, Min. Nominal Max.
14 Quality (%) or Superheat (ºF)
15 Air or Gas Bubbles; Name N Y N Y N Y
16 Size Range % by volume
17 Suspended Solids; Name N Y N Y N Y
18 Size Range % by weight
19 Pipe Diameter Schedule Material
20 Liner Material Insulation Thk, Type
21 ORIFICE PLATE AND FLANGE SPECIFICATIONS
22 Manufacturer Model
23 Plate Type Material
24 Bore Sized for Design Std
Plate

25 Bore Diam., d Thickness in. in. in. in. in. in.


26 DP @ Max. Flow: Allow./Calc. Units *
27 Pipe ID, D b = d/D
28 Flanges & Taps: Supply by
29 Flange Type Rating Material
Flanges

30 Tap Size Location


31 Ring Type (if appl.) Material
32 Vent (top) Drain (btm) Vent (top) Drain (btm) Vent (top) Drain (btm)
Vent, Drain, Other?
5-May-99

33
Date

34 METER SELECTION, MEASUREMENT PARAMETERS


35 Manufacturer Model
36 Meter Type Seal Sp. Gr. @ 60ºF
Rev.
0

37 Range: Diff. (Dry) Static Units


38 Chart or Scale Range Chart Multiplier
39 Other:
Instrument Form No.

40 INSTALLATION, INTERFACE SPECIFICATIONS


41 Area Classification Class Gr Div Class Gr Div Class Gr Div
42 Output Units Housing Requirements
43 Hi Lo Fault Hi Lo Fault Hi Lo Fault
Switches/Alarms
44 Other: Other: Other:
45 Totalizer (check) Min. Range Units
46 Cable Distance (Transducer to Console) feet feet feet
47 Special Requirements:
48
49 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
50
51

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, CORIOLIS Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location Chiclayo, Peru Unit Hacienda Cayalti P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Service or Associated Equipment

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø) Liq Vap Gas
8 Flow, Min. Nominal Max. units gpm gph lb/min
9 Temp., Min. Nominal Max. ºF ºF ºF
10 Press., Min. Nominal Max. psig psig psig
11 Fluid Density @ STP Op'g T&P lb/ft³ g/cc lb/gal
12 Viscosity, Min. Nominal Max. cP SSU cSt
13 Air or Gas Bubbles; Name N Y N Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N Y N Y N ✘ Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk None None A-Swt ¾" Hot 1"
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * * *
21 Conn. Size Type Rating Face 1" WN 125# FF 1½" SW 300# FF 2" SO 150# RF
22 Material, Wetted Parts Gaskets, Rings
23 Meter MAWP Max. Allow. Temp. * psig * ºF * psig * ºF * psig * ºF
24 DP @ Min. Nominal Max. Flow * * * psi * * * psi * * * psi
25 Velocity @ Min. Nominal Max. Flow * * * fps * * * fps * * * fps
26 NRe @ Min. Nominal Max. Flow * * * * * * * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% * * * ±% * * * ±%
28 Density Accuracy * ±g/cc * ±% * ±g/cc * ±% * ±g/cc * ±%
29 Required Accuracy % of Full Scale % of Reading % of Full Scale
5-May-99

30 Required Repeatability % of Full Scale % of Reading % of Reading


Date

31 Other:
32
33 INSTALLATION, INTERFACE SPECIFICATIONS
Rev.
0

34 Area Classification Class II Gr A Div 2 Class II Gr B Div 1 Class III Gr C Div 1


35 Output Units Housing Requirements 4 to 20 mA NEMA-4X Pulse NEMA-7 Digital NEMA-12
36 Hi Lo ✘ Fault Hi ✘ Lo Fault ✘ Hi Lo Fault
Instrument Form No.

Switches/Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, ULTRASONIC Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location Piura, Peru Unit La Pollo Franco P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Assoc. Equip./Service

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø) Liq Gas 2-Ph
8 Flow, Min. Nominal Max. units gpm gpm gpm
9 Temp., Min. Nominal Max. o
F o
F o
F
10 Press., Min. Nominal Max. psig psig psig
11 Fluid Density @ STP @ Op'g T&P lb/ft3 lb/ft3 lb/ft3
12 Viscosity, Min. Nominal Max. cP cP cP
13 Air or Gas Bubbles; Name N Y N Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N Y N ✘ Y N Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk Hot 1" None None Cold 1½"
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * *
21
22
23 Max. Allow. Temp. * psig * ºF psig ºF psig ºF
24 * * * psi psi psi
25 Velocity @ Min. Nominal Max. Flow * * * fps fps fps
26 NRe @ Min. Nominal Max. Flow * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% ±% ±%
28 Density Accuracy * ±g/cc * ±% ±g/cc ±% ±g/cc ±%
29 Required Accuracy % of Full Scale % of Full Scale % of Full Scale
5-May-99

30 Required Repeatability % of Reading % of Full Scale % of Full Scale


Date

31 Other:
32 INSTALLATION, INTERFACE SPECIFICATIONS
33 Area Classification Class Gr Div Class Gr Div Class I Gr A Div 2
Rev.
0

34 Housing Requirements
35 Output Units
36 Hi Lo Fault Hi Lo Fault Hi Lo Fault
Instrument Form No.

Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, MASS Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location Caracas, Venezuela Unit Roberto Humphries P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Assoc. Equip./Service

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø)
8 Flow, Min. Nominal Max. units gpm gpm gpm
9 Temp., Min. Nominal Max. o
F o
F o
F
10 Press., Min. Nominal Max. psig psig psig
11 Fluid Density @ STP @ Op'g T&P lb/ft3 lb/ft3 lb/ft3
12 Viscosity, Min. Nominal Max. cP cP cP
13 Air or Gas Bubbles; Name N Y N Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N ✘ Y N Y N Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk None None Hot None A-Swt 1"
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * *
21
22
23 Max. Allow. Temp. * psig * ºF psig ºF psig ºF
24 * * * psi psi psi
25 Velocity @ Min. Nominal Max. Flow * * * fps fps fps
26 NRe @ Min. Nominal Max. Flow * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% ±% ±%
28 Density Accuracy * ±g/cc * ±% ±g/cc ±% ±g/cc ±%
29 Required Accuracy % of Full Scale % of % of
5-May-99

30 Required Repeatability % of Reading % of % of


Date

31 Other:
32 INSTALLATION, INTERFACE SPECIFICATIONS
33 Area Classification Class I Gr A Div 2 Class II Gr B Div 1 Class III Gr C Div 1
Rev.
0

34 Housing Requirements NEMA-4X NEMA-7 NEMA-4


35 Output Units 4 to 20 mA Pulse Digital
36 Hi Lo ✘ Fault Hi Lo Fault Hi Lo Fault
Instrument Form No.

Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, TURBINE Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location Arica, Chile Unit Martin Busquets P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Assoc. Equip./Service

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø)
8 Flow, Min. Nominal Max. units gpm gpm gpm
9 Temp., Min. Nominal Max. o
F o
F o
F
10 Press., Min. Nominal Max. psig psig psig
11 Fluid Density @ STP @ Op'g T&P lb/ft3 lb/ft3 lb/ft3
12 Viscosity, Min. Nominal Max. cP cP cP
13 Air or Gas Bubbles; Name N Y N Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N Y N Y N Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * *
21
22
23 Max. Allow. Temp. * psig * ºF * psig * ºF * psig * ºF
24 * * * psi psi psi
25 Velocity @ Min. Nominal Max. Flow * * * fps fps fps
26 NRe @ Min. Nominal Max. Flow * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% * * * ±% * * * ±%
28 Density Accuracy * ±g/cc * ±% * ±g/cc * ±% * ±g/cc * ±%
29 Required Accuracy % of Reading % of % of
5-May-99

30 Required Repeatability % of Full Scale % of % of


Date

31 Other:
32 INSTALLATION, INTERFACE SPECIFICATIONS
33 Area Classification Class II Gr A Div 2 Class I Gr A Div 1 Class I Gr C Div 1
Rev.
0

34 Housing Requirements NEMA-4X NEMA-7 NEMA-4


35 Output Units 4 to 20 mA Pulse Pulse
36 Hi Lo Fault Hi Lo Fault Hi Lo Fault
Instrument Form No.

Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units lb kg US gal
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, VORTEX Sheet of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location La Paz, Bolivia Unit Pepe Mendietta P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Assoc. Equip./Service

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø)
8 Flow, Min. Nominal Max. units gpm gpm gpm
9 Temp., Min. Nominal Max. o
F o
F o
F
10 Press., Min. Nominal Max. psig psig psig
11 Fluid Density @ STP @ Op'g T&P lb/ft3 lb/ft3 lb/ft3
12 Viscosity, Min. Nominal Max. cP cP cP
13 Air or Gas Bubbles; Name N Y N Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N Y N ✘ Y N Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * *
21
22
23 Max. Allow. Temp. * psig * ºF psig ºF psig ºF
24 * * * psi psi psi
25 Velocity @ Min. Nominal Max. Flow * * * fps fps fps
26 NRe @ Min. Nominal Max. Flow * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% ±% ±%
28 Density Accuracy * ±g/cc * ±% ±g/cc ±% ±g/cc ±%
29 Required Accuracy % of % of % of
5-May-99

30 Required Repeatability % of % of % of
Date

31 Other:
32 INSTALLATION, INTERFACE SPECIFICATIONS
33 Area Classification Class I Gr A Div 1 Class II Gr B Div 2 Class III Gr C Div 2
Rev.
0

34 Housing Requirements NEMA-12 NEMA-4 NEMA-7


35 Output Units 4 to 20 mA Pulse Digital
36 Hi Lo Fault Hi Lo Fault Hi Lo Fault
Instrument Form No.

Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units lb kg US gal
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
FLOWMETER SPECIFICATION, MAGNETIC Sheet 1 of
Montemayor (English Units)

Rev. No.
Corporation Project No.

1 Location Victoria, TX Unit Nitric Acid al Gusto P.O. No. *


2 Tag Number

3 P&ID Number

4 Line Number

5 Assoc. Equip./Service

6 SERVICE CONDITIONS
7 Fluid Name (l, v, g or 2Ø) Liq Gas 2-Ph
8 Flow, Min. Nominal Max. units gpm lb/min lb/min
9 Temp., Min. Nominal Max. oC oC oC
10 Press., Min. Nominal Max. kPa psia atm
11 Fluid Density @ STP @ Op'g T&P lb/ft³ lb/ft³ lb/ft³
12 Viscosity, Min. Nominal Max. cP SSU cSt
13 Air or Gas Bubbles; Name N Y N ✘ Y N Y
14 Size Range % by volume
15 Suspended Solids; Name N Y N Y N Y
16 Size Range % by weight
17 Pipe Diameter Schedule Material
18 Liner Material Insulation Type, Thk
19 FLOWMETER SELECTION, MEASUREMENT PARAMETERS
20 Manufacturer Model * *
21
22
23 Max. Allow. Temp. * psig * ºF * psig * ºF * psig * ºF
24 * * * psi psi psi
25 Velocity @ Min. Nominal Max. Flow * * * fps fps fps
26 NRe @ Min. Nominal Max. Flow * * *
27 Flow Acc'y @ Min./ Nom. Max. Flow * * * ±% ±% ±%
28 Density Accuracy * ±g/cc * ±% ±g/cc ±% ±g/cc ±%
29 Required Accuracy % of Full Scale % of Reading % of Full Scale
5-May-99

30 Required Repeatability % of Reading % of Full Scale % of Reading


Date

31 Other:
32 INSTALLATION, INTERFACE SPECIFICATIONS
33 Area Classification Class I Gr A Div 1 Class II Gr B Div 1 Class III Gr C Div 2
Rev.
0

34 Housing Requirements NEMA-4X NEMA-7 NEMA-4


35 Output Units 4 to 20 mA Pulse Digital
36 Hi Lo Fault Hi Lo Fault Hi Lo Fault
Instrument Form No.

Alarms
37 Other: Other: Other:
38 Totalizer (check) Min. Range Units lb kg US gal
39 Cable Distance (Transducer to Console) feet feet feet
40 Special Requirements:
41
42
43
44
45 Remarks 1. Items marked by an asterisk (*) to be completed by Vendor/Mfr.
46
47
48

Rev Date Description By Chk. Appr. Rev Date Description By Chk. Appr.