55

30 min. fire fire wall


resistant

25 .00 M
OVER FLOW COLD WATER L180
BALL VALVE SUPPLY TANK
1m high pool fence

2697
500L HOT 2 M BUILDING/SERVITUDE LINE

4397
WATER
STORAGE
TANK
BEARER
THERMOSTAT
1m approne GENERAL NOTES
DRAINAGE NOTES:
ANTI-KNOCK * ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OF SANITARY FITTINGS
& INSULATION pool 2662 TO COMPLY WITH THE RELEVANT LOCAL AUTHORITY BYLAWS, REGULATIONS &
EXPANSION REQUIREMENTS.
LOOP * ALL SOIL PIPES MUST BE 110[ PVC
ELECTRICAL SU * ALL WASTE PIPES MUST BE 50[ PVC
NL

600
HEATING TO A IGH * PROVIDE IE'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT NGL.
ELEMENT BEARER BSO T
RBE * MINIMUM FALLS TO DRAINPIPES TO BE 1-60 UNLESS OTHERWISE INDICATED.
R PAN * PROVIDE RESEAL TRAPS TO ALL WASTE FITTINGS.
EL 1468
* PROVIDE ANTI-VAC TRAPS ON ALL 1ST FLOOR FITTINGS.
ROOF TRUSS * PROVIDE AE'S TO FOOT OF ALL SOIL STACKS.
POWER SUPPLY * IE'S TO ALL PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES AND SOIL PIPES
PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN A MIN. OF 100mm

1270
CONC.

1m approne
* ONE TAP OVER ONE GULLY WILL BE SUPPLIED.
* DRAIN PIPES, IE'S AND CE'S TO BE CLEAR OF ANY FOUNDATIONS OR PAVING
AND EASILY ACCESSIBLE
HOT WATER SUPPLY Keep this distance short

2M NUILDING LINE
GENERAL:
COLD WATER SUPPLY BOOMER * ALL WORK TO BE IN ACCORDANCE WITH LOCAL
WATER FROM MAIN SUPPLY 1:50 SCALE SOLAR HOT WATER SYSTEM BYLAWS, WORK TO FIGURED DIMENSIONS ONLY.

30 .00 M

30 .00 M
* DO NOT SCALE DRAWING.
* OVERALL EXTERNAL DIMS TO TAKE PRECEDENCE.
3591 * ALL DIMENSIONS TO BE CHECKED ON SITE BEFORE CONSTRUCTION.
* FINAL LEVELS HEIGHT OF PLINTHS, DEPTHS OF EXCAVATIONS & NUMBER OF STEPS
TO BE DETERMINED ON SITE BY CONSTRUCTOR.
* ALL MATERIALS, FITTINGS, FINISHES ETC. TO BE FULL APPROVAL OF THE OWNER.
* ALL STEPS TO CONFORM TPO SABS REGULATIONS.
ARROW INDICATING ROOF KITCHEN YARD *SEWERAGE
IN CASE OFNOTE:
DOUBT - ASK
TILE FLOW dove grey * ALL WASTE PIPES TO BE 50[ PVC
CONCRETE ROOF TILE * ALL SOIL PIPES TO BE 100[ PVC
PERGOLA STRUCUTURE interlocking paving * FOUNDATIONS TO BE RE-INFORCED
PITCHED @ 30 DEG bricks OVER SOIL PIPES RUNNING UNDER
ANY BUILDINGS.
Better Architectural Projects
Pty (Ltd)
Cell 060 920 2623
PERGOLA STRUCUTURE MAIN BUILDING Cell 2 076 266 9117
CONCRETE ROOF TILE 423 M/2 braai area
PITCHED @ 30 DEG betterarchitects@mail.com
GROUND ANF FIRST FLOOR 03 Kalafong heights Atteridgeville

ARROW INDICATING ROOF *0-0.75m = 3mm GLASS. 0008

2M NUILDING LINE
CONCRETE ROOF TILE *0.75m-1.5m = 4mm GLASS
TILE FLOW
PITCHED @ 30 DEG *1.5m-2.0m = 5mm glass
*4mm OBSCUERED GLASS GLAZING
2620 BATHROMS
CONCRETE ROOF TILE GLAZING AS PER PART N OF
PITCHED @ 30 DEG NBR
ELECTRIC LAYOUT
5710
BRAAI AREA
KEY DESCRIPTION

1m approne
1m approne CEILING LIGHT POINT
1m approne
WALL MOUNTED LIGHT POINT
1
a14 LIGHT SWITCHES
1m wide ramp
dove grey 15 AMP PLUG POINT
1
interlocking paving
a14 bricks
MB METER BOX
CONCRETE ROOF TILE DISTRIBUTION BOX
DB

5103
PITCHED @ 30 DEG
CONCRETE ROOF TILE 1m wide ramp
2M STREET BUILDING LINE FLORESCENT
PITCHED @ 30 DEG
dove grey

2703
CONCRETE ROOF TILE
PITCHED @ 30 DEG ERF 42 interlocking paving
bricks
ERF 44 G GEYSER POINT

ERF 1734 TELEPHONE POINT

RELEVISION POINT
CONCRETE ROOF TILE
ARROW INDICATING ROOF
TILE FLOW
ENTRANCE/ EXIT 25 .00 M
PITCHED @ 30 DEG NO OBSTRUCTION
CONCRETE ROOF TILE
STREET CLIENT/OWNER
PITCHED @ 30 DEG MNISI
FOOT PRINT & SITE PLAN PROJECT TITLE
SCALE 1:100 NEW PROPOSSED DWELLING
CONCRETE ROOF TILE
PITCHED @ 30 DEG CONCRETE ROOF TILE ERF 43
PITCHED @ 30 DEG
NOTES.
ESTATE D' AFRIQUE
ARROW INDICATING ROOF
TILE FLOW CONCRETE ROOF TILE -Provide for 100mm dia. stormwater outlets every 2n in the MNISI
PITCHED @ 30 DEG boundary wall at the lowest point of the property.
-Plumbing shall be ducted and suitably screened(Duct to be made of
walls and to be painted with earthy colours to match the house.
-Non gravel/solid concrete driveways will be accepted.
AREAS
-Natural contours not to be increased by more than 500mm. GROUND FLOOR FIRST FLOOR TOTAL

FIRE NOTE: 268M/2 155M/2 423M/2


any opening closer than 5m to any garage to be fitted ROOF RIDGE
with 30min fire rated ceiling DETAIL(scale1:50) SITE COVERAGE
ROOF PLAN New Note For The Reqiurements:
750M/2 56%

SCALE 1:100 no combustible componets to penetrate the separating


element dividing the space between garages and Concrete Roof Tiles at 24 deg. Pitch On USB 35
habitable rooms
500
Micron Green Plastic Underlay On 38x38mm Grade
DPC Garage door to be a fire door and wall to be a fire wall 6, SA Pine Batterns At 345mm ctc On Grade 6,
of 230mm thick 85mm down step from inside to outside 114x38mm SA Pine Wall Plates Trusses To Be
Metal roof sheeting NGL Drawn by Scales used DATE
55 of house to garage.
Secured Into Brick Work With 2x4mm Galvanised
Steel Wire Strands Built At Least Six Courses Into LEBO As shown
230 x 600 Brick Work.
FOUNDATION FIRE NOTE: Sacap Reg Signature
fire wall 30 min. fire [100mm UPVC NO COMBUSTIBLE ROOF COMPONENTS SHALL PENETRATE
45°

resistant THE SEPARATING ELEMENTS


DIVIDING THE SPACE BETWEEN THE GARAGE AND
THE HABITABLE ROOM
DRAWING NUMBER
SEWER DETAIL 914
Scale 1:50
12
PAGE 1 OF 1