This describes RNC parameters, including the meaning, values, and usage of RNC parameters.
Version
Intended Audience
•Network planners
•Field engineers
•System engineers
•Shift operators
Organization
Description
Parameter ID
Parameter Name
MML Command
NE
Description
Related Feature
Value Type
GUI Value Range
Unit
Default Value
Recommended Value
Impact
Parameter Relationship
Service Interrupted After Modification
Interruption Scope
Access
Attribute
Remarks
Simple string for identifying a parameter
Full name of the parameter
Commands for setting the parameter, and optional/mandatory attribute of the
parameter in each command
NEs on which the parameter is set
Functions, functioning ways, and protocols of the parameter
Features for which the parameter is used
Parameter value type
Parameter value range displayed on the GUI
Actual parameter value range corresponding to the GUI Value Range. For
example, the GUI Value Range is 0, and the corresponding Actual Value
Range is OFF.
Parameter value unit
Initial value provided by the system
Values recommended in different scenarios
Parameter impact scope, that is, objects specified when the parameter is set
Relationship between this parameter and other parameters. For example, to
use this parameter, you need to set related switches and parameters.
Whether modifying the parameter value may interrupt the existing services
Possible interruption scope in the case that modifying the parameter value
may interrupt the existing services
Possible interruption duration in the case that modifying the parameter value
may interrupt the existing services
Cautions to be taken during the modification
ADD PPPLNK(Optional)
ADD MPLNK(Optional)
SET DSACAUTOALGO(Mandatory)
SET ACALGO(Mandatory)
AcRstrctIntervalLen Interval length of Domai RNC
AcRstrctPercent AC Restriction Percent RNC SET ACALGO(Mandatory)
AcRstrctSwitch AC Restriction Switch RNC SET ACALGO(Optional)
ACTOBJECT Activate Object RNC ACT LICENSE(Mandatory)
ACTTYPE Type RNC ACT GPS(Mandatory)
ACU Added CPU occupancy RNC STR CPUUSAGETST(Mandatory)
AFSetObj AFSetObj RNC SET ADMCTRL(Mandatory)
AgpsActivateFlag A-GPS Method Active Fl RNC ADD SMLCCELL(Optional)
AGPSAddAssDataSe A-GPS Additional Data RNC SET SMLC(Optional)
AGPSMethodType A-GPS Method Type RNC SET SMLC(Optional)
ADD GPS(Mandatory)
AGPSRECEIVERID GPS ID RNC ACT GPS(Mandatory)
AGPSRECEIVERTY GPS type RNC ADD GPS(Mandatory)
AICHPowerOffset AICH power offset RNC ADD CHPWROFFSET(Optional)
AICHTxTiming AICH transmission timin RNC ADD AICH(Optional)
SET ALMLVL(Mandatory)
SET BOXRPT(Mandatory)
SET ALMPORT(Optional)
ADD
CELLINTERFREQHONCOV(Option
al)
SET
INTERFREQHONCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHONCOV(Optional
)
SET INTERRATHONCOV(Optional)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD CELLSETUP(Mandatory)
ADD
QUICKCELLSETUP(Mandatory)
ADD GSMCELL(Optional)
ADD NRNCCELL(Mandatory)
ADD CELLDCCC(Optional)
SET DCCC(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD PPPLNK(Optional)
ADD IMAGRP(Optional)
ADD FRALNK(Optional)
ADD UNILNK(Optional)
ADD MPGRP(Optional)
ADD PPPLNK(Optional)
ADD IMAGRP(Optional)
ADD FRALNK(Optional)
ADD UNILNK(Optional)
ADD MPGRP(Optional)
ADD IPOAPVC(Optional)
ADD SAALLNK(Mandatory)
ADD AAL2PATH(Mandatory)
ADD IPOAPVC(Mandatory)
ADD AAL2PATH(Mandatory)
ADD SAALLNK(Mandatory)
ADD AAL2PATH(Mandatory)
ADD SAALLNK(Mandatory)
ADD IPOAPVC(Optional)
ADD SAALLNK(Mandatory)
ADD AAL2PATH(Mandatory)
ADD SAALLNK(Mandatory)
ADD IPOAPVC(Optional)
ADD IPOAPVC(Mandatory)
ADD SAALLNK(Mandatory)
ADD AAL2PATH(Mandatory)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD INTERFREQNCELL(Optional)
ADD INTRAFREQNCELL(Optional)
CIOOffset Neighboring cell oriente RNC
CIR Bandwidth RNC ADD IPLOGICPORT(Mandatory)
CLKTYPE Clock board type RNC SET CLKTYPE(Mandatory)
CLTAModeInd Closed loop time adjust RNC ADD CELLSETUP(Optional)
CmCap Compression mode capabiRNC ADD NODEBLMTPARA(Optional)
ADD CELLCMCF(Optional)
SET CMCF(Optional)
ADD CNDOMAIN(Mandatory)
ADD CELLRLPWR(Mandatory)
ADD TYPRABBASIC(Mandatory)
ADD CNNODE(Mandatory)
RST IURESOURCE(Mandatory)
RST IU(Mandatory)
ADD NRNCCELL(Mandatory)
ADD GSMCELL(Mandatory)
ADD
QUICKCELLSETUP(Mandatory)
ADD CELLSETUP(Mandatory)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET DRD(Optional)
ADD CELLDRD(Optional)
ADD CELLHOCOMM(Optional)
SET HOCOMM(Optional)
ADD CELLDCCC(Optional)
SET DCCC(Optional)
ADD CELLAMRCWB(Optional)
SET AMRCWB(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD
CELLINTERRATHONCOV(Optional
)
SET INTERRATHONCOV(Optional)
ADD SCCPCHBASIC(Optional)
ADD PRACHBASIC(Optional)
ADD CELLSELRESEL(Mandatory)
ADD NRNCCELL(Mandatory)
ADD M3DE(Mandatory)
ADD M3RT(Mandatory)
ADD M3LKS(Mandatory)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
SET AMRC(Optional)
SET AMRCWB(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLQOSHO(Optional)
SET QOSHO(Optional)
ADD CELLQOSHO(Optional)
SET QOSHO(Optional)
ADD CELLCMCF(Optional)
SET CMCF(Optional)
SET AMRC(Optional)
SET AMRCWB(Optional)
SET AMRC(Optional)
SET AMRCWB(Optional)
SET AMRC(Optional)
SET AMRCWB(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD N7DPC(Mandatory)
ADD M3DE(Mandatory)
ADD MTP3LKS(Mandatory)
ADD ADJNODE(Mandatory)
ADD CNNODE(Mandatory)
ADD NRNC(Mandatory)
ADD MTP3RT(Mandatory)
SET DRD(Optional)
ADD CELLDRD(Optional)
ADD PPPLNK(Mandatory)
ADD MPLNK(Mandatory)
PING IP(Optional)
SET DSCPMAP(Mandatory)
ADD SCTPLNK(Optional)
SET PHBMAP(Mandatory)
ADD IPRT(Mandatory)
ADD IPRTBIND(Mandatory)
SET FRC(Optional)
ADD CELLFRC(Optional)
SET FRC(Optional)
ADD CELLFRC(Optional)
ADD CELLMBMSFACH(Optional)
SET MBMSFACH(Optional)
SET MSCHFACH(Optional)
ADD FRALNK(Optional)
ADD IMAGRP(Optional)
SET OPT(Mandatory)
SET ETHPORT(Mandatory)
ADD MPGRP(Optional)
ADD PPPLNK(Optional)
ADD UNILNK(Optional)
ADD ATMLOGICPORT(Optional)
ADD
PORTFLOWCTRLPARA(Mandatory)
ADD IPLOGICPORT(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
EXP CFGMML(Optional)
BKP DB(Optional)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)
ADD FRALNK(Optional)
ADD IMAGRP(Optional)
ADD UNILNK(Optional)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)
ADD FRALNK(Optional)
ADD IMAGRP(Optional)
ADD UNILNK(Optional)
ADD IPLOGICPORT(Optional)
ADD CELLAMRCWB(Optional)
SET AMRCWB(Optional)
ADD CELLAMRC(Optional)
SET AMRC(Optional)
ADD CELLHCS(Optional)
ADD GSMCELL(Optional)
ADD NRNCCELL(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERFREQHONCOV(Option
al)
SET
INTERFREQHONCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD INTERFREQNCELL(Optional)
ADD INTRAFREQNCELL(Optional)
IdleQoffset1sn IdleQoffset1sn RNC
ADD INTERFREQNCELL(Optional)
ADD INTRAFREQNCELL(Optional)
IdleQoffset2sn IdleQoffset2sn RNC
IdleSintersearch Inter-freq cell reselectio RNC ADD CELLSELRESEL(Optional)
IdleSintrasearch Intra-freq cell reselectio RNC ADD CELLSELRESEL(Optional)
IdleTbarred Time barred for SIB3 RNC ADD CELLACCESSSTRICT(Optional
ADD IMALNK(Mandatory)
STR IMATST(Mandatory)
RMV IMALNK(Mandatory)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERFREQHONCOV(Option
al)
SET
INTERFREQHONCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERFREQHONCOV(Option
al)
SET
INTERFREQHONCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHONCOV(Optional
)
SET INTERRATHONCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD ETHTRKIP(Mandatory)
RMV ETHTRKIP(Mandatory)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET DRD(Optional)
ADD CELLDRD(Optional)
ADD M3LE(Mandatory)
ADD M3DE(Mandatory)
ACT VCLCC(Mandatory)
LOP VCL(Mandatory)
SET E1T1LOP(Mandatory)
SET OPTLOP(Mandatory)
ADD IPLOGICPORT(Mandatory)
RMV IPLOGICPORT(Mandatory)
ADD IPPATH(Mandatory)
SET E1T1(Optional)
SET COPTLNK(Mandatory)
ADD ETHMA(Mandatory)
ADD ETHMEP(Mandatory)
ACT ETHCC(Mandatory)
PING MAC(Mandatory)
TRC MAC(Mandatory)
ADD CELLSELRESEL(Optional)
ADD NRNCCELL(Mandatory)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD CELLSETUP(Optional)
ADD QUICKCELLSETUP(Optional)
MaxTxPower Max transmit power of ce RNC
MaxUlTxPowerforBa Max UL TX power of bacRNC ADD CELLCAC(Optional)
MaxUlTxPowerforC Max UL TX power of conv RNC ADD CELLCAC(Optional)
MaxUlTxPowerforIn Max UL TX power of inteRNC ADD CELLCAC(Optional)
MaxUlTxPowerforSt Max UL TX power of str RNC ADD CELLCAC(Optional)
MaxUserNumCodeAdMax user number of code RNC ADD CELLLDR(Optional)
MBDRFlag The flag of the MBDR RNC ADD GSMNCELL(Optional)
MBDRFlag The flag of the MBDR RNC ADD INTERFREQNCELL(Optional)
MBDRPrio The priority of MBDR ne RNC ADD GSMNCELL(Optional)
MBDRPrio The priority of MBDR ne RNC ADD INTERFREQNCELL(Optional)
MBFDCHKN Check Check Index RNC ADD IPRTBIND(Mandatory)
MBFDLOCALIP Multi hop BFD detect loc RNC STR IPCHK(Mandatory)
MBFDSN Check Slot No. RNC ADD IPRTBIND(Mandatory)
MBFDSRN Check Subrack No. RNC ADD IPRTBIND(Mandatory)
MbmsAF AF of MBMS service RNC SET ADMCTRL(Optional)
MBMSCCHDL MBMS common channel se RNC ADD TRMFACTOR(Optional)
MbmsChInd Mbms Channel Indicator RNC ADD SCCPCHBASIC(Optional)
MbmsDecPowerRab MBMS descend power rabRNC ADD CELLLDR(Optional)
MbmsInactTmr Set mbms data check tim RNC SET MBMSALARMPARA(Mandatory
MbmsIubSharingSwi MBMS Iub Sharing swit RNC SET MBMSSWITCH(Optional)
MbmsMCC Mobile country code RNC ADD MBMSALARMSERVICE(Mandat
MbmsMNC Mobile network code RNC ADD MBMSALARMSERVICE(Mandat
MbmsNCellInd MBMS neighboring cell i RNC ADD INTRAFREQNCELL(Optional)
MbmsOlcRelNum MBMS services number r RNC ADD CELLOLC(Optional)
MbmsPreemptAlgoSwMbms PreemptAlgoSwit RNC SET QUEUEPREEMPT(Optional)
MbmsPtpUlBitRate Mbms Ptp UpLink Bit Ra RNC SET RNCMBMSPARA(Optional)
ADD CELLMBMSSA(Mandatory)
ADD MBMSSA(Mandatory)
ADD SAMBMSPARA(Mandatory)
ADD CELLMBMSPARA(Optional)
ADD SAMBMSPARA(Optional)
SET RNCMBMSPARA(Optional)
ADD CNOPERATOR(Mandatory)
ADD LASNAMAP(Mandatory)
ADD IMSISNAMAP(Mandatory)
ADD GSMCELL(Mandatory)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLQUALITYMEAS(Mandatory)
SET QUALITYMEAS(Mandatory)
ADD
CELLQUALITYMEAS(Mandatory)
SET QUALITYMEAS(Mandatory)
ADD
CELLQUALITYMEAS(Mandatory)
SET QUALITYMEAS(Mandatory)
ADD CNOPERATOR(Mandatory)
ADD GSMCELL(Mandatory)
ADD LASNAMAP(Mandatory)
ADD IMSISNAMAP(Mandatory)
ADD MPGRP(Mandatory)
RMV MPGRP(Mandatory)
ADD MPLNK(Mandatory)
ADD CELLMBMSFACH(Optional)
SET MBMSFACH(Optional)
ADD CELLMBMSFACH(Optional)
SET MBMSFACH(Optional)
SET ETHPORT(Optional)
ADD SCTPLNK(Optional)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)
ADD MTP3RT(Mandatory)
ADD MTP3LKS(Mandatory)
ADD ADJNODE(Mandatory)
ADD MTP3LNK(Mandatory)
ADD M3DE(Mandatory)
ADD M3LE(Mandatory)
ADD M3LKS(Mandatory)
ADD M3LNK(Mandatory)
ADD M3RT(Mandatory)
ADD N7DPC(Mandatory)
ADD OPC(Mandatory)
ADD CELLMBMSPARA(Optional)
ADD SAMBMSPARA(Optional)
SET RNCMBMSPARA(Optional)
ADD IPRT(Mandatory)
ADD IPRTBIND(Mandatory)
ADD CELLHCSHO(Optional)
SET HCSHO(Optional)
ADD ADJNODE(Mandatory)
ADD NODEBIP(Mandatory)
ADD NODEBESN(Mandatory)
STR NODEBDETECT(Mandatory)
ADD INTERFREQNCELL(Optional)
ADD INTRAFREQNCELL(Optional)
ADD GSMNCELL(Optional)
NPrioFlag The flag of the priority RNC
ADD CELLMBMSPARA(Optional)
ADD SAMBMSPARA(Optional)
SET RNCMBMSPARA(Optional)
ADD CELLHCSHO(Optional)
SET HCSHO(Optional)
ADD PPPLNK(Optional)
SET ETHPORT(Optional)
ADD MPGRP(Optional)
ADD IPLOGICPORT(Optional)
SET LDCPERIOD(Optional)
SET SATLDCPERIOD(Optional)
ADD AAL2PATH(Mandatory)
ACT VCLCC(Mandatory)
ADD IPPATH(Mandatory)
ACT IPPM(Mandatory)
ADD IPPATHBIND(Mandatory)
ADD PCPICH(Optional)
ADD QUICKCELLSETUP(Optional)
PCPICHPower PCPICH transmit power RNC
PCPICHPowerPace Pilot power adjustment s RNC ADD CELLLDB(Optional)
PCR Peak cell rate RNC ADD ATMTRF(Optional)
ADD QUICKCELLSETUP(Optional)
ADD CELLSETUP(Optional)
PeerIsValid Peer Cell Is Valid Or Not RNC
PEERMASK Peer subnet mask RNC ADD IPPATH(Optional)
PeerNodebId Peer NodeB ID RNC ADD NODEB(Mandatory)
PEERPN Destination SCTP port N RNC ADD SCTPLNK(Mandatory)
PeerRncId Peer RNC ID RNC ADD NODEB(Mandatory)
PEERT Peer type RNC ADD IPOAPVC(Mandatory)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERFREQHONCOV(Option
al)
SET
INTERFREQHONCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERRATHONCOV(Optional
)
SET INTERRATHONCOV(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD PPPLNK(Optional)
ADD MPLNK(Optional)
ADD LAC(Mandatory)
ADD RAC(Mandatory)
ADD PPPLNK(Optional)
RST PPPLNK(Mandatory)
ADD MPLNK(Mandatory)
RST MPLNK(Mandatory)
RMV PPPLNK(Mandatory)
RMV MPLNK(Mandatory)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)
ADD MTP3LNK(Optional)
ADD M3LNK(Optional)
ADD MTP3RT(Optional)
ADD M3RT(Optional)
ADD
CELLINTERRATHONCOV(Optional
)
SET INTERRATHONCOV(Optional)
ADD CELLHCS(Optional)
ADD GSMCELL(Optional)
ADD NRNCCELL(Optional)
ADD CELLSELRESEL(Optional)
ADD NRNCCELL(Mandatory)
ADD CELLSELRESEL(Optional)
ADD NRNCCELL(Mandatory)
ADD CELLSELRESEL(Optional)
ADD NRNCCELL(Optional)
ADD RAC(Mandatory)
ADD CELLSETUP(Mandatory)
ADD
QUICKCELLSETUP(Mandatory)
ADD GSMCELL(Mandatory)
ADD NRNCCELL(Mandatory)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET REDIRECTION(Optional)
ADD
CELLREDIRECTION(Optional)
SET REDIRECTION(Optional)
ADD
CELLREDIRECTION(Optional)
SET REDIRECTION(Optional)
ADD
CELLREDIRECTION(Optional)
SET DRD(Optional)
ADD CELLDRD(Optional)
SET REDIRECTION(Optional)
ADD
CELLREDIRECTION(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
ADD PPPLNK(Optional)
ADD MPLNK(Optional)
ADD GPS(Mandatory)
RST RNC(Mandatory)
ADD IPLOGICPORT(Mandatory)
ADD RSCGRP(Mandatory)
ADD
CELLALGOSWITCH(Optional)
ADD
NODEBALGOPARA(Optional)
SET CACALGOSWITCH(Optional)
ADD SAALLNK(Mandatory)
ADD AAL2PATH(Mandatory)
ADD VPCLCX(Mandatory)
ADD IPOAPVC(Optional)
ADD SAC(Mandatory)
ADD CELLSETUP(Mandatory)
ADD
QUICKCELLSETUP(Mandatory)
ADD CZ(Mandatory)
SET E1T1(Optional)
SET OPT(Optional)
ADD SCTPLNK(Mandatory)
ADD M3LNK(Mandatory)
ADD CCP(Mandatory)
ADD NCP(Mandatory)
ADD
CELLMBMSSCCPCH(Mandatory)
SET MBMSSCCPCH(Mandatory)
ADD
CELLMBMSFACH(Mandatory)
SET MBMSFACH(Mandatory)
SET MTCH(Mandatory)
SET DRD(Optional)
ADD CELLDRD(Optional)
ADD
CELLMBMSSCCPCH(Mandatory)
SET MBMSSCCPCH(Mandatory)
ADD
CELLMBMSFACH(Mandatory)
SET MBMSFACH(Mandatory)
SET MTCH(Mandatory)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
SET SMLC(Mandatory)
ADD INTRAFREQNCELL(Optional)
ADD INTERFREQNCELL(Optional)
ADD GSMNCELL(Optional)
SIB11Ind SIB11 Indicator RNC
ADD INTRAFREQNCELL(Optional)
ADD INTERFREQNCELL(Optional)
ADD GSMNCELL(Optional)
SIB12Ind SIB12 Indicator RNC
SibCfgBitMap SIB switch RNC ADD CELLSIBSWITCH(Optional)
SigChType channel type for RRC es RNC SET RRCESTCAUSE(Optional)
ADD MTP3LKS(Mandatory)
ADD MTP3LNK(Mandatory)
ADD MTP3RT(Mandatory)
ADD M3RT(Mandatory)
ADD M3LKS(Mandatory)
ADD M3LNK(Mandatory)
ADD CELLAMRCWB(Optional)
SET AMRCWB(Optional)
PING MAC(Mandatory)
TRC MAC(Mandatory)
ADD SPG(Mandatory)
ADD CELLSETUP(Mandatory)
ADD
QUICKCELLSETUP(Mandatory)
ADD CLKSRC(Mandatory)
RMV CLKSRC(Mandatory)
ADD CBSADDR(Mandatory)
SET
NCELLDETECTSWITCH(Mandatory
)
ADD IURCOMMSCCP(Mandatory)
ADD SCCPCHBASIC(Optional)
ADD AICH(Optional)
ADD PICH(Optional)
ADD
CELLMBMSSCCPCH(Optional)
SET MBMSSCCPCH(Optional)
ADD CELLSETUP(Optional)
ADD NRNCCELL(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD FACHDYNTFS(Optional)
ADD PCHDYNTFS(Optional)
ADD RACHDYNTFS(Optional)
ADD CELLHCSHO(Optional)
SET HCSHO(Optional)
ADD INTRAFREQNCELL(Optional)
ADD INTERFREQNCELL(Optional)
ADD GSMNCELL(Optional)
TempOffset1 HCS Cell Reselect Temp RNC
ADD INTRAFREQNCELL(Optional)
ADD INTERFREQNCELL(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
SET LDM(Mandatory)
SET SATLDM(Mandatory)
SET LDM(Mandatory)
SET SATLDM(Mandatory)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD CELLHCSHO(Optional)
SET HCSHO(Optional)
ADD FACH(Mandatory)
ADD PCH(Optional)
ADD CELLMBMSFACH(Optional)
SET MBMSFACH(Optional)
ADD FACH(Mandatory)
ADD PCH(Optional)
ADD CELLMBMSFACH(Optional)
SET MBMSFACH(Optional)
ADD INTRAFREQNCELL(Optional)
ADD INTERFREQNCELL(Optional)
ADD GSMNCELL(Optional)
ADD TRMMAP(Mandatory)
ADD ADJMAP(Mandatory)
ADD ADJNODE(Mandatory)
ADD CELLHCSHO(Optional)
SET HCSHO(Optional)
ADD ATMTRF(Mandatory)
RMV ATMTRF(Mandatory)
ADD ETHTRKLNK(Mandatory)
RMV ETHTRKLNK(Mandatory)
ADD ETHTRK(Mandatory)
RMV ETHTRK(Mandatory)
ADD ETHTRKIP(Mandatory)
RMV ETHTRKIP(Mandatory)
ADD ETHTRKLNK(Mandatory)
ADD PPPLNK(Mandatory)
ADD FRALNK(Mandatory)
ADD MPLNK(Mandatory)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
SET FRCCHLTYPEPARA(Optional)
ADD CELLFRC(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLDCCC(Optional)
SET DCCC(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
SET AMRC(Optional)
SET AMRCWB(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLLDR(Optional)
ADD NODEBLDR(Optional)
ADD CELLQOSHO(Optional)
SET QOSHO(Optional)
ADD CELLCMCF(Optional)
SET CMCF(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD
CELLQUALITYMEAS(Optional)
SET QUALITYMEAS(Optional)
ADD URA(Mandatory)
ADD CELLURA(Mandatory)
ADD NRNCURA(Mandatory)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD
CELLINTERFREQHOCOV(Optional
)
SET INTERFREQHOCOV(Optional)
ADD
CELLINTERRATHOCOV(Optional)
SET INTERRATHOCOV(Optional)
ADD CELLHCS(Optional)
ADD GSMCELL(Optional)
ADD NRNCCELL(Optional)
ADD SCTPLNK(Optional)
ADD IPPATH(Optional)
ADD QUICKCELLSETUP(Optional)
ADD CELLSETUP(Optional)
VPLimitInd Cell VP limit indicator RNC
VPQosPerform QOS Switch For VP Traf RNC SET QOSACT(Optional)
VpRabAbnormRelRa VP drop ratio Per Spu RNC SET KPIALMTHD(Optional)
VpRabEstAttMinNu The minimum of VP Rab aRNC SET KPIALMTHD(Optional)
VpRabEstSuccRatio VP Rab successful setup RNC SET KPIALMTHD(Optional)
VpRabRelMinNum The number of VP drop P RNC SET KPIALMTHD(Optional)
WAmrUlRateAdjTim Wait Timer For WAMR RNC SET QOSACT(Optional)
WATER_MASK Enable Water Alarm Rep RNC MOD EMU(Optional)
ADD
CELLINTRAFREQHO(Optional)
SET INTRAFREQHO(Optional)
Address and co None Enumeration Disable, Enable Disable (not support None
Interval of au Flow Control Interval Typ 1~36000 10~360000, step:10 ms
Specifies the None Interval Typ 1~36000 1~36000 None
Specifies the r None Bit Field Ty AC0, AC1, AC2, AC0,AC1,AC2,AC3 None
User_priority
corresponding
to
Allocation/Re
tention
priority 8.
Load Control Enumeration Gold, Silver, Copp Gold,Silver,Copper None
User_priority Load Control Enumeration Gold, Silver, Copp Gold,Silver,Copper None
ARP packet res IP RAN Interval Typ 3~10 3 to 10 None
ARP packet ou IP RAN Interval Typ 3~10 300 to 1000 ms
This parameter None Interval Typ 0~255 0 to 255 None
Number of the None Interval Typ 14~27 14 to 27 None
Number of the None Interval Typ 0~5 0 to 5 None
Indicating wh UE Behaviors in I Enumeration NOT_ALLOWED, NOT_ALLOWED, None
Indicating the Inter-RAT Handov Enumeration Band1, Band2, Ba Band1, Band2, Band None
This parameter Load Control Interval Typ 1~1000 1~1000 kbit/s
Uniquely(511-
number: ident Inter-RAT Handov Interval Typ 0~7 0~7 None
866) Inter-RAT Handov Interval Typ 0~1023 0~1023 None
GSM900
This paramete HSPA+ Interval Typ -350~150 -35~15,step:0.1 dB
This paramete HSPA+ Interval Typ -350~150 -35~15,step:0.1 dB
Offset of the Power Control Interval Typ -350~150 -35~15, step: 0.1 dB
Indicating th None Enumeration MTP3, M3UA MTP3, M3UA None
This
parameter
specifies the
bearer type of
the service.
- R99: The
service is
carried on a
non-HSPA
channel.
- HSPA: The
service is
carried on an
HSPA
channel.
Iub Overbooking Enumeration R99, HSPA R99, HSPA None
The bit rate t Intra-Frequency H Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
The first acti DCCC Enumeration None, RateDegrade None, RateDegrade, None
The second act DCCC Enumeration None, RateDegrade None, RateDegrade, None
The third acti DCCC Enumeration None, RateDegrade None, RateDegrade, None
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Upper threshol DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
Time to trigge DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Traffic volume DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
Time to trigge DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Upper threshol DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
Time to trigge DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Timer for stat DCCC Interval Typ 1~65535 1~65535 s
Pending time a DCCC Enumeration D250, D500, D100 250, 500, 1000, 200 ms
This parameter DCCC Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, byte
When the traff DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter HSUPA Enumeration D8, D16, D32, D6 8,16,32,64,128,144 kbit/s
Timer for reje DCCC Interval Typ 0~1024 0~1024 s
This parameter Load Control Compound T hour, min, sec hour{0~23}, min{0 None
When the numbe Load Control Interval Typ 0~10 0~10 None
This parameter Load Control Compound T hour, min, sec hour{0~23}, min{0 None
When the paramLoad Control Enumeration OFF, ON OFF, ON None
The difference Load Control Interval Typ 1~100 0.1~10, step:0.1 dBm
This parameter Power Control Interval Typ -63~0 5*10^(-7)~1 None
handover to
this cell
cannot be Inter-RAT HandoveEnumeration FALSE, TRUE FALSE,TRUE None
This parameter Inter-Frequency H Enumeration D1, D2, D4, D8 1,2,4,8 None
This parameter
neighboring Inter-Frequency H Enumeration D250, D500 250,500 ms
cells, which Inter-RAT Handov Interval Typ 0~30 0~30 None
cells of the
can ensure Inter-Frequency H Interval Typ -115~-25 -115~-25 dBm
same
event 1F,
exceeds the
specified
threshold.
Otherwise, the
report will be
discarded.
This
parameter is Inter-Frequency H Interval Typ -115~-25 -115~-25 dBm
This timer is None Interval Typ 2000~60000 2000~60000 ms
New Report to None Enumeration nonrpt(Not Report) nonrpt,rpt None
This parameter None Enumeration INT, DPU, XPU INT,DPU,XPU None
This parameter None Enumeration PEUa, AEUa, FG2 PEUa,AEUa,FG2a, None
Type of the bo None Enumeration FG2a, GOUa FG2a, GOUa None
Board type. None Enumeration PEUa, POUa, UOI PEUa, POUa, UOIa None
Board type. None Enumeration PEUa, POUa PEUa,POUa None
correctly;
when the
value is
NOT_REQUI
RE,
measurement
reporting is
triggered
whatever the
BSIC is
deciphered or
not, if the
measured cell
meets the
reporting
conditions.
This
parameter is
triggered Inter-RAT Handov Enumeration REQUIRED(Verify REQUIRED, NOT_ None
valid for both
whatever the Inter-RAT Handov Enumeration REQUIRED(Verify REQUIRED,NOT_ None
BSIC
Type isof the bo None Enumeration AEUa, PEUa, AOU AEUa,AOUa,PEUa None
Type of the bo None Enumeration AEUa, PEUa, AOU AEUa, PEUa, AOUa None
Type of the bo IP RAN Enumeration PEUa(PEUa), AE AEUa, PEUa, AOUa None
This parameter None Enumeration SCUa, GCUa, GCGSCUa, GCUa, GCGaNone
This parameter None Enumeration AEUa, PEUa, AOU AEUa, PEUa, AOUa None
Type of the bo None Enumeration AEUa, PEUa, AOU AEUa, PEUa, AOUa None
This parameter None Enumeration SCUa, GCUa/GCG SCUa, GCUa/GCGa None
Type of the bo None Enumeration AEUa, AOUa AEUa, AOUa None
This parameter None Enumeration AOUa, POUa, UOI AOUa, POUa, UOIa None
Board type. Transmission Res Enumeration AEUa, AOUa, UOI AEUa, AOUa, UOIa None
Automatic bandTransmission Res Enumeration OFF, ON OFF, ON None
SAAL, SCTP, SIP RAN Enumeration SAAL(SAAL Link SAAL, SCTP, SAA None
If the cell dow Load Control Interval Typ 0~100 0~1, step:0.01 per cent
If you set thi Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
If you set thi Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
If you set thi Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
If you set thi Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
If you set thi
measurement Load Control Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
report period.
If you set this Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
parameter to
If you set thi Load Control, Iub Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
This parameter AMRC, AMRC-W Enumeration TEN_MSEC, MIN TEN_MSEC, MIN None
This parameter Load Control Interval Typ 0~100 0~100 per cent
This parameter Load Control Enumeration SF4, SF8, SF16, S SF4, SF8, SF16, SF None
This
parameter
specifies
whether the
code
balancing
DRD
algorithm will
be applied.
- ON: The
code
balancing
DRD
algorithm will
be applied.
- OFF: The
code
balancing
DRD
algorithm will
not be
applied.
code Load Control Enumeration ON, OFF ON, OFF None
resources Load Control Enumeration FALSE(FALSE), FALSE, TRUE None
present a
the message
thresholds forc CBS Enumeration GERMAN(German),GERMAN, ENGLIS None
inter-RAT
measurement.
When you set
the previous
parameters,
consider the
following
factors: event
2D/2F
measurement
thresholds for
inter- Inter-Frequency H Enumeration COEXIST_MEAS COEXIST_MEAS_ None
frequency
For a PTM servMBMS Service Interval Typ 0~100 0~1,step: 0.01 per cent
Indicating the
channel type
of CS speech
service.
-DCH: Both
uplink and
downlink are
beared on
DCH.
-
HSPA:Uplink
is beared on
E-DCH,
downlink
beared on HS-
DSCH.
Radio Bearers, H Enumeration DCH(UL_DCH,DL DCH,HSPA None
This parameter AMRC, AMRC-WBInterval Typ -100~100 -100~100 ms
This parameter AMRC, AMRC-WBInterval Typ -100~100 -100~100 ms
This parameter AMRC, AMRC-WBEnumeration EDCH_TTI_10ms, EDCH_TTI_10ms, None
Indicating wh Flow Control Enumeration OFF, ON OFF, ON None
This
parameter
specifies the
direction that
the traffic
volume
measurement
is applicable
to.
-
DOWNLINK:
indicates
downlink
traffic volume
measurement.
- UPLINK:
indicates
uplink traffic
volume
measurement
or E-DCH
throughput
measurement.
L3 filtering co Load Control, Iub Enumeration D0, D1, D2, D3, D D0, D1, D2, D3, D4 None
This parameter None Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
This parameter Radio Bearers Enumeration D8, D16 8, 16 kbit/s
DL BE traffic I Load Control, DC Enumeration D8, D16, D32, D6 8,16,32,64,128,144, kbit/s
This parameter Radio Bearers, H Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
Different admi Load Control Interval Typ 0~100 0~1, step:0.01 None
The percentage Load Control Interval Typ 0~100 0~1, step:0.01 None
The percentage Load Control Interval Typ 0~100 0~1, step:0.01 None
Number of userLoad Control Interval Typ 1~10 1~10 None
For a BE servi DCCC Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
Maximum DL rat DCCC Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
This parameter Load Control, DC Enumeration D0, D8, D16, D32 0, 8, 16, 32, 64, 128 kbit/s
Some cell reso Load Control Enumeration SF4(SF4), SF8(SF SF4,SF8,SF16,SF3 None
this service
will be
rejected. If the
DL load of a
cell will not
be higher than
this threshold,
this service
will be
admitted.
The DL load
factor
thresholds
include
parameters of
[DL threshold
of Conv
non_AMR
service], [DL
handover
access
threshold] and
[DL threshold
of other
services]. The
four
parameters
can be used to
limit the
proportion
between the
non-handover
service,
handover user Load Control Interval Typ 0~100 0~1, step:0.01 None
Reserved DL p Load Control Interval Typ 0~100 0~1, step:0.01 None
DL activity fac Load Control Interval Typ 0~100 0~1, step: 0.01 None
gives rise to
Load Control Interval Typ 0~400000 0~400000 bit/s
the fluctuation
The inter-freq Load Control Interval Typ 0~100 0~1, step:0.01 per cent
The mechanismLoad Control Interval Typ 1~10 1~10 None
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
Number of RABs
Load Control Interval Typ 1~10 1~10 None
Reserved SF th Load Control Enumeration SF4(SF4), SF8(SF SF4,SF8,SF16,SF32 None
This parameter Load Control Enumeration NoAct(no action), NoAct,InterFreqL None
Number of RABs
Load Control Interval Typ 1~10 1~10 None
If the ratio o Load Control Interval Typ 0~100 0~1, step:0.01 per cent
Smooth filteri DCCC, AMRC, Enumeration D0, D1, D2, D3, D 0, 1, 2, 3, 4, 5, 6, 7 None
This parameter DCCC Enumeration AUTO_CALC, H 0, 1 None
Threshold of t DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 144 kbit/s
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
parameter
defines the
maximum
number of
RABs
selected in
executing
downlink
OLC fast
restriction.
Selection of
RABs of the
OLC is based
on the service
priorities and
ARP values
and bearing
priority
indication.
The RAB of
low priority is
under control.
In the actual
system,
UlOlcFTFRstr
ctRabNum
and
DlOlcFTFRstr
ctRabNum
can be set on
the basis of
the actual
circumstances
. If the high- Load Control Interval Typ 1~10 1~10 None
rate
parameter
defines the
maximum
number of
downlink
OLC fast TF
restriction
performed in
entering/exitin
g the OLC
status.
After the
overload is
triggered, the
RNC
immediately
executes OLC
by first
executing fast
TF restriction.
The internal
counter is
incremented
by 1 with each
execution. If
the number of
overloads
does not
exceed the
OLC action
threshold, the
system lowers
the BE service
rate by Load Control Interval Typ 0~100 0~100 None
lowering TF
L3 filtering co Load Control, Iub Enumeration D0, D1, D2, D3, D D0, D1, D2, D3, D4 None
If the ratio o Load Control Interval Typ 0~100 0~1, step:0.01 per cent
released in
Load Control Interval Typ 0~10 0~10 None
executing
DL OLC triggerLoad Control, Iub Interval Typ 1~6000 10~60000, step:10 None
If the
the DLratio
loadoof Load Control Interval Typ 0~100 0~1, step:0.01 per cent
a cell is higher
than this
threshold after
the access of a
service, this
service will be
rejected. If the
DL load of a
cell will not
be higher than
this threshold,
this service
will be
admitted.
The DL load
factor
thresholds
include
parameters of
[DL threshold
of Conv
non_AMR
service], [DL
handover
access
threshold] and
[DL threshold
of other
services]. The
four
parameters
can be used to
limit the Load Control Interval Typ 0~100 0~1, step:0.01 None
proportion
Orthogonal Va Load Control Enumeration SF4, SF8, SF16, S SF4,SF8,SF16,SF32 None
This paramete HSPA+,HSDPA Enumeration None, STTD, CP1 None, STTD, CP1 None
This parameter Channel Descripti Enumeration None, STTD, CP1 None, STTD, CP1 None
applicable to Power Control
Enumeration SINGLE_TPC, T SINGLE_TPC, TP None
soft handover,
point
None Enumeration IUCS(Iu-CS node) IUCS, IUPS, IUR None
IUCS_ALCA
This parameter None Interval Typ 1024~3584 1024 to 3584 None
This parameter None Interval Typ 8~19 8 to 19 None
The little tar Power Control, H Interval Typ 0~15000 0~15, step:0.001 None
This parameter DCCC Interval Typ 0~1023 0~1023 None
This parameter DCCC Interval Typ 0~1023 0~1023 None
This parameter Radio Bearers Enumeration EDCH_10MS, ED EDCH_10MS,EDC None
EFACH channelIub Overbooking Interval Typ 0~100 0~100 per cent
This paramete HSPA+ Interval Typ -350~150 -35~15,step:0.1 dB
E_FACH support Intra-Frequency H Enumeration TRUE, FALSE FALSE,TRUE None
This parameter Radio Bearers Enumeration OFF, ON OFF, ON None
This parameter Inter-Frequency Enumeration FALSE(Forbidden) FALSE,TRUE None
Type of the en None Enumeration DATE, WEEK, D DATE, WEEK, D None
When the switc Load Control Enumeration OFF, ON OFF, ON None
It indicates w None Enumeration OFF, ON OFF, ON None
This parameter LCS Enumeration OFF, ON OFF, ON None
End month of None Enumeration JAN(January), FE JAN, FEB, MAR, A None
This parameter None IP Address - 0.0.0.0~255.255.25 None
The encryptio Data Integrity Pro Bit Field Ty UEA0~0 UEA1 For each switch of None
End time of th None Compound T HOUR, MIN 00:00~23:59 min
End time of th None Compound T HOUR, MIN 00:00~23:59 min
End time of th None Compound T HOUR, MIN 00:00~23:59 min
This paramete MBMS Service Interval Typ -350~150 -35~15, step: 0.1 dB
Indicating whe UE Behaviors in I Enumeration REQUIRE, NOT_ REQUIRE,NOT_R None
This parameter Load Control Interval Typ 0~30 0~3,step:0.1 dB
Active factor None Interval Typ 0~100 0%~100% per cent
This parameter Iub Overbooking Interval Typ 0~100 0~100 per cent
This parameter DCCC Interval Typ 1~255 1~255 None
FC indicates w None Enumeration ENABLE, DISAB ENABLE, DISABL None
This
parameter
specifies the
type of link
that carries
the high-end
VPL/VCL
cross
connection.
GUI value
range: UNI,
IMA,
FRAATM,
NCOPT.
None Enumeration UNI, IMA, FRAA UNI, IMA, FRAAT None
This parameter Load Control Interval Typ 0~300 0~300 s
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
This parameter HSDPA Enumeration None, STTD, CP1 None, STTD, CP1 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter HSDPA Interval Typ 1~15 1~15 None
This parameter HSUPA Enumeration D10, D20, D50, D 10, 20, 50, 100, 200 ms
This parameter HSUPA Enumeration D10, D20, D50, D 10, 20, 50, 100, 200 ms
This parameter HSUPA Enumeration D2, D10, D20, D5 2,10, 20, 50, 100, 2 ms
This parameter HSUPA Enumeration D2, D10, D20, D5 2,10, 20, 50, 100, 2 ms
UL activity fa Load Control Interval Typ 0~100 0~1, step: 0.01 None
Threshold for Intra-Frequency Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
When the dyna Load Control
BasedonUECa Enumeration MBR, GBR MBR, GBR None
p, you can Inter-Frequency Enumeration Limited, Permit, For each switch of None
infer that the
UL activity fa Load Control Interval Typ 0~100 0~1, step: 0.01 None
Strategy of t DCCC, HSUPA Enumeration RATE_UP_AND_ RATE_UP_AND_D None
Threshold of a Load Control Interval Typ 0~100 0~1, step:0.01 per cent
Threshold of a Load Control Interval Typ 0~100 0~1, step:0.01 per cent
HSUPA BE traffDCCC Enumeration D8, D16, D32, D6 8,16,32,64,128,144 kbit/s
UL activity fa Load Control Interval Typ 0~100 0~1, step: 0.01 None
Threshold of a Load Control Interval Typ 0~100 0~1, step:0.01 per cent
Length of smooLoad Control Interval Typ 1~32 1~32 None
The number of None Interval Typ 0~65534 0~65534 None
HSUPA Rab succ None Interval Typ 0~100 0~100 None
UL activity fa Load Control Interval Typ 0~100 0~1, step: 0.01 None
The total HSUPNone Interval Typ 0~3264000 0 to 3264000 kbit/s
HSUPA auto retLoad Control Interval Typ 0~100 0~1, step:0.01 per cent
HSUPA auto retLoad Control Interval Typ 0~100 0~1, step:0.01 per cent
The cell will None Interval Typ 0~5 0~5 None
HSUPA backgr Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA backgroTransmission Res Interval Typ 0~100 0~100 None
HSUPA backgr Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA backgroTransmission Res Interval Typ 0~100 0~100 None
HSUPA backgroIub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA conversTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA conversTransmission Res Interval Typ 0~100 0~100 None
HSUPA conversTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA conversaTransmission Res Interval Typ 0~100 0~100 None
HSUPA conversaIub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA high priTransmission Res Interval Typ 0~100 0~100 None
HSUPA high priTransmission Res Interval Typ 0~100 0~100 None
HSUPA interactIub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA high PR Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA high PR Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA low PRI Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA low PRI Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA middleTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA middleTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA low prioTransmission Res Interval Typ 0~100 0~100 None
HSUPA low prioTransmission Res Interval Typ 0~100 0~100 None
This parameter None Enumeration CLOSE(Close), O CLOSE,OPEN None
This parameter None String Type - 1~9 character per cent
This parameter None String Type - 1~9 character per cent
HSUPA middleTransmission
p Res Interval Typ 0~100 0~100 None
HSUPA middleTransmission
p Res Interval Typ 0~100 0~100 None
This parameter None Interval Typ 0~167 0 to 167 None
HSUPA Signal Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA IMS Sig Transmission Res Interval Typ 0~100 0~100 None
HSUPA Signal Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA IMS Sig Transmission Res Interval Typ 0~100 0~100 None
HSUPA IMS upl Iub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA Signal Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA Signal Transmission Res Interval Typ 0~100 0~100 None
HSUPA Signal Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA Signal Transmission
p Res Interval Typ 0~100 0~100 None
HSUPA SRB upl Iub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA streamiTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA streamiTransmission Res Interval Typ 0~100 0~100 None
HSUPA streamiTransmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA streamiTransmission Res Interval Typ 0~100 0~100 None
HSUPA streamiIub Overbooking Interval Typ 0~100 0~100 per cent
HSUPA Voice Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA Voice Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
HSUPA voice se Iub Overbooking Interval Typ 0~100 0~100 per cent
This parameter None Interval Typ 32~65535 32 to 65535 None
This parameter None Interval Typ 0~255 0 to 255 None
handover, the
hysteresis of
event 1A
should be set
a little smaller
than those of
events 1B, 1F,
1C, and 1D.
But the
difference
should not be
too large,
otherwise the
soft handover
ratio can be
affected. In
addition, this
parameter is
related to
filter
coefficient
and trigger
delay.
As for the
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis
means
decrease Intra-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
As for theof
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis Intra-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
As for the
means
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis Intra-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
means
As for the
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis Intra-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
As for the
means
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis Inter-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
As for the
means
impact on
network
performance:
For the UE
that enters the
SHO area,
increase of the
hysteresis Intra-Frequency H Interval Typ 0~15 0~7.5,Step:0.5 dB
means
stronger the
capability of
resisting
signal
fluctuation.
Thus, the
ping-pong
effect can be
resisted, but
the speed ofthe Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB/ dBm
parameter,
stronger the
capability of
resisting
signal
fluctuation.
Thus, the
ping-pong
effect can be
resisted, but
the speed of Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB
the handover
fluctuation.
Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB
Thus, the
estimated
quality of the
currently used
frequency is
higher than
the threshold).
Event 2D is
used to enable
the
compressed
mode and
event 2F is
used to
disable the
compressed
mode.
Therefore,
Hystfor2D
can be
increased on
the basis of
recommended
value and
inter-
frequency
handover
ping-pong
effect
statistics.
Hystfor2F can
also be
increased to
reduce
frequent Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB/ dBm
enabling or
estimated
quality of the
currently used
frequency is
higher than
the threshold).
Event 2D is
used to enable
the
compressed
mode and
event 2F is
used to
disable the
compressed
mode.
Therefore,
Hystfor2D
can be
increased on
the basis of
recommended
value and
inter-
frequency
handover
ping-pong
effect
statistics.
Hystfor2F can
also be
increased to
reduce
frequent Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB/ dBm
enabling or
lower. If the
inter-RAT
handover
hysteresis is
set to an
excessively
high value,
the GSM cell
to which the
UE is handed
over must be
of good
quality.
Therefore, the
conditions for
triggering the
inter-RAT
handover
decision are
hard to be
satisfied, and
the call drop
rate increases.
The emulation
result shows
that in a cell
where the
average
moving speed
of UEs is
high, for
example a cell
that covers
highways, Inter-RAT Handov Interval Typ 0~15 0~7.5,Step:0.5 dB
HystforInterR
lower. If the
inter-RAT
handover
hysteresis is
set to an
excessively
high value,
the GSM cell
to which the
UE hands
over must be
of good
quality.
Therefore, the
conditions for
triggering the
inter-RAT
handover
decision are
hard to be
satisfied, and
the call drop
rate increases.
The emulation
result shows
that in a cell
where the
average
moving speed
of UEs is
high, for
example a cell
that covers
highways, Inter-RAT Handov Interval Typ 0~15 0~7.5,Step:0.5 dB
HystforInterR
lower. If the
inter-RAT
handover
hysteresis is
set to an
excessively
high value,
the GSM cell
to which the
UE hands
over must be
of good
quality.
Therefore, the
conditions for
triggering the
inter-RAT
handover
decision are
hard to be
satisfied, and
the call drop
rate increases.
The emulation
result shows
that in a cell
where the
average
moving speed
of UEs is
high, for
example a cell
that covers
highways, Inter-RAT Handov Interval Typ 0~15 0~7.5,Step:0.5 dB
HystforInterR
Thus, the
ping-pong
effect can be
avoided, but
the speed of
the handover
algorithm to
respond to
signal change
becomes
lower. If the
inter-RAT
handover
hysteresis is
set to an
excessively
high value,
the GSM cell
to which the
UE is handed
over must be
of good
quality.
Therefore, the
conditions for
triggering the
inter-RAT
handover
decision are
hard to be
satisfied, and
the call drop
rate increases.
The emulation Inter-RAT Handov Interval Typ 0~15 0~7.5,Step:0.5 dB
larger the
value of this
parameter, the
stronger the
capability of
resisting
signal
fluctuation.
Thus, the
ping-pong Inter-Frequency H Interval Typ 0~29 0~14.5,Step:0.5 dB/ dBm
capability of Inter-Frequency H
Interval Typ 0~29 0~14.5,Step:0.5 dB/ dBm
resisting
After a connect None Interval Typ 180~1260 180~1260 s
After a connect None Interval Typ 60~600 60~600 s
The ICMP Packe IP RAN Interval Typ 44~1024 44~1024 byte
Number of the None Interval Typ 1~30,100~32767 1~30,100~32767 None
Indicating whe UE Behaviors in I Enumeration BARRED, NOT_ BARRED, NOT_B None
Indicating whe UE Behaviors in I Enumeration ALLOWED, NOT ALLOWED, NOT_ None
updates
(URA_PCH),
or cell updates
(CELL_FAC
H,
CELL_PCH),
and thus
increase the
load of
network
signaling and
the
consumption
of UE
batteries. Set a
proper
measurement
hysteresis to
reduce as
much as
possible effect
of the slow
fading as well
as ensuring
timely cell
updates of the
UE.
According to
the CPICH
RSCP
emulation
report of
inter-
frequency UE Behaviors in I Interval Typ 0~20 0~40, step:2 dB
pong effect
may trigger
frequent
location
updates (idle
mode), URA
updates
(URA_PCH),
or cell updates
(CELL_FAC
H,
CELL_PCH),
and thus
increase the
load of
network
signaling and
the
consumption
of UE
batteries. Set a
proper
measurement
hysteresis to
reduce as
much as
possible effect
of the slow
fading as well
as ensuring
timely cell
updates of the
UE.
According to UE Behaviors in I Interval Typ 0~20,255 {0~40},{255}, step: dB
In
thecell
CPICH
reselection
algorithm, this
parameter is UE Behaviors in I Interval Typ -50~50 -50~50 dB
used
borderforof a
cell. This
parameter can
be configured UE Behaviors in I Interval Typ -50~50 -50~50 dB
Threshold for UE Behaviors in I Interval Typ -16~10,127 {-32~20},{127}, ste dB
Threshold for UE Behaviors in I Interval Typ -16~10,127 {-32~20},{127}, ste dB
This parameter UE Behaviors in I Enumeration D10, D20, D40, D 10, 20, 40, 80, 160, s
UNI: 10000~30000
Interval for s None Interval Typ 100~30000 NNI: 100~30000 ms
After the cove Inter-Frequency H Interval Typ 0~120 0~120 s
CN flow controFlow Control, Iu F Interval Typ 5000~30000 5000~30000 ms
Number of the None Interval Typ 0~83 0 to 31(AEUa),0 to None
IMA ID. None Interval Typ 0~255 0 to 255 None
-Periodical
report mode
When the Inter-RAT Handov Enumeration PERIODICAL_REPO
PERIODICAL_RE None
of event-
triggered
report mode is
that the event
is reported
only once and
cannot be
changed to
periodical
mode. If the
handover
fails, the
periodical
report is
triggered only
by the internal
timer. For the
cell-oriented
algorithm
parameters,
each time the
best cell is
updated, the
inter-
frequency
measurement
parameters
should be
updated
accordingly.
-Periodical
report mode
When the Inter-RAT Handov Enumeration PERIODICAL_REPO
PERIODICAL_RE None
This parameter UE Behaviors in I Interval Typ 4~19,255 {1~4.75},{255}, ste None
UL theshold Inter-RAT Handov Interval Typ 0~100 0~100 None
This parameter None Interval Typ 1~10 1 to 10 s
The
emergency
blind
handover is a
special
occasion that
requires on-
site
measurements
on the scope
of the pilot
strength of the
best cell at the
location
where the
blind
handover is
triggered.
Generally,
this function
need not be
started, so the
parameter is
set to the
lowest value
by default,
indicating that
the blind
handover is
not triggered.
The larger the
set value is,
the more
easily the Inter-Frequency H Interval Typ -24~0 -24~0 dB
call drop.
The
emergency
blind
handover is a
special
occasion that
requires on-
site
measurements
on the scope
of the pilot
strength of the
best cell at the
location
where the
blind
handover is
triggered.
Generally,
this function
need not be
started, so the
parameter is
set to the
lowest value
by default,
indicating that
the blind
handover is
not triggered.
The larger the
set value is,
the more Inter-Frequency H Interval Typ -115~-25 -115~-25 dBm
easily the
much random
impulse as
possible. Thus
the filtered
measurement
value can
reflect the
varying of the
actual
measurement
value. The
input
measurement
value to L3
filter has been
filtered by L1
filter, where
the impact of
fast fading is
almost
eliminated. So
the L3
filtering
should apply
smooth
filtering to
shadow fading
and small
amount of
remaining fast
fading, thus
providing
more reliable
measurement Intra-Frequency H Enumeration D0, D1, D2, D3, D 0,1,2,3,4,5,6,7,8,9, None
value for
Identifying th Load Control, Iub Interval Typ 1~86400 1~86400 s
Indicating whe Intra-Frequency H Enumeration REQUIRE, NOT_ REQUIRE,NOT_R None
This
parameter
specifies
whether the
MAC-hs
window size
is fixed.
- If this
parameter is
set to TRUE,
the MAC-hs
window size
is fixed.
- If this
parameter is
set to FALSE,
the MAC-hs
window size
is flexible.
Interface type. Transmission Res Enumeration IUB, IUR, IUCS, IUB,IUR,IUCS,IUP None
When the Iu in Flow Control Interval Typ 1~3600 1~3600 s
Number of RABs Load Control Interval Typ 0~10 0~10 None
Number of RABs Load Control Interval Typ 0~10 0~10 None
A timer to Iu None Interval Typ 1~65535 1~65535 s
A timer to Iu None Interval Typ 1~65535 1~65535 s
Indicating whe Flow Control Enumeration OFF, ON OFF, ON None
Indicating wh SRNS Relocation Enumeration TRUE, FALSE TRUE, FALSE None
Indicating whe Intra-Frequency H Enumeration OFF, ON OFF, ON None
Indicating whe Intra-Frequency H Enumeration OFF, ON OFF, ON None
Iu signaling c None Interval Typ 0~16777215 0~16777215 None
This parameter None Enumeration NULL, 1byte, 16by NULL, 1 byte, 16 by None
This parameter None String Type - None None
J0 TX type.Thi None Enumeration NULL, 1byte, 16by NULL, 1 byte, 16 by None
J0 TX value.ThNone String Type - None None
Expected J1 RXNone Enumeration NULL, 1byte, 16by NULL,1byte,16byte None
This parameter None String Type - None None
This parameter None Enumeration NULL, 1byte, 16by NULL, 1 byte, 16 by None
This parameter None String Type - None None
This parameter None Enumeration NULL, 16byte, 64b NULL, 16 byte, 64 None
This parameter None String Type - 1~15 characters None
This parameter None Enumeration NULL, 16byte, 64b NULL, 16 byte, 64 None
This parameter Load Control Interval Typ 0~100 0~100 per cent
This parameter Load Control Interval Typ 0~100 0~100 per cent
This parameter Load Control Interval Typ 0~100 0~100 per cent
This parameter Load Control Interval Typ 0~100 0~100 per cent
DRD
algorithm will
be applied.(If
cell-level
DRD
parameters are Load Control Enumeration ON, OFF ON, OFF None
configured,
DRD
algorithm will
be applied.(If
cell-level
DRD
parameters are Load Control Enumeration ON, OFF ON, OFF None
configured,
This parameter Load Control Interval Typ 0~100 0~100 per cent
T_LDR_SWI
TCH: Local
cell group
credit
congestion
control
algorithm.
This is an
RNC-oriented
algorithm.
When the
local cell
group creadit
load is heavy,
the load can
be reshuffled
through BE
service rate
reduction,
renegotiation
of
uncontrollable
real-time
service QoS,
and CS/PS
inter-RAT
handover.
LC_CREDIT_
LDR_SWITC
H: Local cell
credit
congestion
control
algorithm. Load Control Bit Field Ty NODEB_CREDIT_NODEB_CREDIT_ None
FALSE means no Load Control Enumeration FALSE(FALSE), FALSE, TRUE None
Code resource uLoad Control Interval Typ 0~100 0~1, step:0.01 per cent
LDR action
processing
trigged of Load Control
by Iub
Enumeration IUBLDR(Iub load r IUBLDR,CODELD None
LDR action Load Control Enumeration IUBLDR(Iub load r IUBLDR,CODELD None
value is
trigged by Iub
excessively
processing
high, the LDR of Load Control, Iub Interval Typ 1~86400 1~86400 s
LDR action Load Control Enumeration IUBLDR(Iub load r IUBLDR,CODELD None
LDR action
trigged by Iub Load Control Enumeration IUBLDR(Iub load r IUBLDR,CODELD None
trigged by Iub
Path Load EQ None Interval Typ 1~63 1~63 None
Index of the l RAN Sharing Interval Typ 0~63 0~63 None
Index of the l RAN Sharing Interval Typ 0~63 0~63 None
Index of the l RAN Sharing Interval Typ 0~63 0~63 None
Coding type
of the line.
1. HDB3 and
AMI are
applicable to
E1 links, and
B8ZS and
AMI_ZCS are
applicable to
T1 links.
2. The value
of this
parameter
should be
consistent
with the peer
one.
None Enumeration B8ZS(B8ZS), HD B8ZS, HDB3, AMI None
Number of the None Interval Typ 0~167 0 to 167 None
M3UA_MASTER_
MOD,
M3UA_SLAVE_M
OD
(For definitions of
the two modes,
refer to RFC4666.)
Link work mod IP RAN Enumeration M3UA_MASTER_ None
Used for MTP3None Enumeration B0000, B0001, B0 B0000, B0001, B00 None
Frame Structur None Enumeration E1_DOUBLE_FR E1_DOUBLE_FRA None
This
parameter
specifies the
maximum
coverage of
the cell
antenna.
This is
controlled by
MTRLGY
and valid
when
IMP~1(British
measurement)
.
LCS Interval Typ 3~328080 3~328080 m
If the number None Interval Typ 0~254 0~254 None
the RNC to
Inter-Frequency H Interval Typ 0~3 {0~3} None
perform
perform inter-
inter-
Inter-RAT Handov Interval Typ 0~3 {0~3} None
RAT
Maximum bandw
Transmission Res Interval Typ 1~1000 64~64000 step:64 kbit/s
Maximum number
Flow Control Interval Typ 0~255 0~255 None
Maximum queueLoad
t Control Interval Typ 1~60 1~60 s
Maximum lengtNone Interval Typ 1~1500 1 to 1500 byte
Sum of the maxNone Interval Typ 0~500 0~50, step: 0.1 dBm
The maximum ULPower Control Interval Typ -50~33 -50~33 dBm
Maximum UL traPower Control Interval Typ -50~33 -50~33 dBm
The maximum UL Power Control Interval Typ -50~33 -50~33 dBm
Maximum UL tra Power Control Interval Typ -50~33 -50~33 dBm
indicates that Load Control
This parameter Interval Typ 1~3 1~3 None
indicates that Inter-RAT Handov
the Enumeration FALSE(Do not end FALSE,TRUE None
neighboring
indicates that Inter-RAT Handov
the Enumeration FALSE(Do not end FALSE,TRUE None
neighboring
the
indicates that Inter-RAT Handov Interval Typ 0~15 0~15 None
neighboring
the Inter-RAT Handov Interval Typ 0~15 0~15 None
neighboring
This parameter None Interval Typ 0~31 0 to 31 None
Backup port ga IP RAN IP Address - 0.0.0.0~255.255.25 None
This parameter None Interval Typ 14~27 14 to 27 None
This parameter None Interval Typ 0~5 0 to 5 None
Activity facto Load Control Interval Typ 0~100 0~1, step: 0.01 None
MBMS commonIub c Overbooking Interval Typ 0~100 0~100 per cent
Indicating wh None Enumeration COMMON, MCCHCOMMON, MCCH None
When the prior Load Control Interval Typ 1~15 1~15 None
A timer used MBMS Service Interval Typ 1~10 1~10 min
ON denotes en MBMS Service Enumeration OFF(OFF), ON(ONOFF, ON None
mobile countr MBMS Service String Type - 000~999 None
mobile networ MBMS Service String Type - 000~999 None
It is an indic MBMS Service Enumeration FALSE, TRUE FALSE,TRUE None
in each [OLC Load Control, MB
Interval Typ 0~8 0~8 None
period] and
Indicating wh Load Control Enumeration OFF, ON OFF, ON None
This parameter MBMS Service Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
This parameter MBMS Service Enumeration PTM, PTP, ENH PTM, PTP, ENHA None
This parameter None Interval Typ 3~10000 3 to 10000 byte
DL basic commo
Load Control, Iub Interval Typ 1~60 1~60 min
This parameter Load Control, Iub Interval Typ 1~60 1~60 min
HSDPA power rLoad Control, Iub Interval Typ 1~60 1~60 min
This parameter Load Control Interval Typ 1~60 1~60 min
UL basic commo
Load Control, Iub Interval Typ 1~60 1~60 min
SPARE_5_SWITC
H,
SPARE_6_SWITC
H
This parameter MBMS Service Interval Typ 0~100 0~1, step: 0.01 per cent
This parameter MBMS Service Interval Typ 0~100 0~1, step: 0.01 per cent
This parameter MBMS Service Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 kbit/s
This paramete MBMS Service Enumeration True, False TRUE, FALSE None
Available gua Load Control Interval Typ 0~100 0~1, step:0.01 None
Available gua Load Control Interval Typ 0~63 0~63 None
Maximum number
UE Behaviors in I Enumeration D1, D2, D4, D10, D1, D2, D4, D10, D None
Maximum number
Cell Update Enumeration D1, D2, D4, D10, D1, D2, D4, D10, D None
Maximum number
Cell Update Enumeration D1, D2, D4, D10, D1, D2, D4, D10, D None
Maximum numbCell Update Enumeration D1, D2, D3, D4 D1,D2,D3,D4 None
Thecells
the algorithms
in Load
w Control Enumeration NBM_LDC_ALL_UE(SNBM_LDC_MATC None
question are Load Control Enumeration ALGORITHM_RE H_UE_FIRST
ALGORITHM_REQ None
algorithm
in the same will
Load Control Enumeration ALGORITHM_OF ALGORITHM_OFF None
be used in
This parameter Load Control Bit Field Ty PRIORITY1, PRIO PRIORITY1, PRIO None
WPS (Wireless Load Control Enumeration ALGORITHM_OFF( ALGORITHM_OFF None
When the RRC None Interval Typ 1~200 1~200 None
NodeB Trans None Enumeration ATMTRANS_IP, ATMTRANS_IP, I None
Uniquely ident Inter-RAT Handov Interval Typ 0~7 0~7 None
When the numbe MBMS Service Interval Typ 2~10 2~10 None
When this para Inter-RAT Handov Enumeration OFF, ON OFF, ON None
Maximum number UE Behaviors in I Interval Typ 1~16 1~16 None
Indicating whe None Enumeration NO(NO_DIRECT_ NO, YES None
Value range:
0~65535.
Physical unit:
None.
Content:
NodeB ID.
Recommende
d value: None.
None Interval Typ 0~65535 0 to 65535 None
Value range:
0 to 65535
Content:
NodeB ID
Recommende
d value
(default
value): none
None Interval Typ 0~65535 0 to 65535 None
OAM flow min Transmission Res Interval Typ 0~100 0%~100% per cent
DSCP of the OATransmission Res Interval Typ 0~63 0 to 63 None
OAM flow min None Enumeration OFF, ON OFF,ON None
Offset of Qoffs Load Control Interval Typ -20~20 -20~20 dB
Offset of Qoffs Load Control Interval Typ -20~20 -20~20 dB
Offset of Qoffs Load Control Interval Typ -20~20 -20~20 dB
Offset of Qoffs Load Control Interval Typ -20~20 -20~20 dB
Offset of Sint Load Control Interval Typ -10~10 -20~20,step:2 dB
Offset of Sinte Load Control
load Interval Typ -10~10 -20~20, step:2 dB
measurement
responds to
the step-
function
signals is
about 2.8s,
namely that
the system
can trace the
load control
effect about 3
s later after
each load
control. In this
case, the OLC
period timer
length cannot
be smaller
than 3s.
OlcPeriodTim
erLen along
with
ULOLCFTFR
strctUserNum,
DLOLCFTFR
strctUserNum,
ULOLCFTFR
STRCTTimes,
DLOLCFTFR
STRCTTimes,
ULOLCTraff
RelUserNum,
and Load Control, Iub Interval Typ 100~86400000 100~86400000 ms
DLOLCTraff
Cn operator ty RAN Sharing Enumeration PRIM(Primary Ope PRIM,SEC,OUTE None
This parameter None Enumeration TRCH_DCH, TR TRCH_DCH, TRC None
This parameter None Enumeration MAP_MODE_LUCMAP_MODE_LUC None
This parameter LCS Bit Field Ty R5_PosData_SWIT R5_PosData_SWIT None
This parameter None Enumeration SDH, SONET SDH, SONET None
Azimuth of the LCS Interval Typ 0~179 0~179 degree
This parameter None Enumeration One_touch(For all One_touch (for all None
Flag of OTDOALCS Enumeration INACTIVE, ACTI INACTIVE, ACTIV None
UE positioni LCS Enumeration UE_BASED, UE_ UE_BASED, UE_A None
handover.
None Enumeration FORBIDDEN, NO FORBIDDEN,NOT None
When the flag
Ownership of Transmission Res Enumeration PEER, LOCAL PEER, LOCAL None
Indicating whe None Enumeration NO(ATM_ADDRE NO,YES None
For IUPS Path IP RAN Enumeration ENABLED, DISA ENABLED, DISA None
AAL2 path ID. None Interval Typ 1~4294967295 1 to 4294967295 None
TX power of th Power Control Interval Typ -100~500 -10~50, step: 0.1 dBm
Pilot power ad Load Control Interval Typ 0~100 0~10, step:0.1 dB
Physical unit:
cell/s or
kbit/s.
2. PCR must
not exceed the
maximum
bandwidth of
the carrier
such as the
IMA group,
UNI link or
optical port.
3. Different
service types
with different
value
ranges.CBR:7
1 to 353207
(UT =
CELL/S)/30
to 149759
(UT = None Interval Typ 30~353207 30 to 353207 None
6)
KBIT/S);RTV
PC_HSUPA_
HARQNUM_
AUTO_ADJU
ST_SWITCH:
When the
switch is
selected, the
HSUPA
service can
use the
smaller target
number of
retransmission
s when the
uplink is not
congested. If
the uplink is
congested, the
HSUPA
service can
use the typical
target number
of
retransmission
s.
7)
PC_HSUPA_
PO_UPDATE
_SWITCH:
When this
switch and the
OLPC switch
are both Power Control Bit Field Ty PC_AMR_MODE_ PC_AMR_MODE_I None
selected, the
PENDING timeNone Interval Typ 1~10 1~10 s
This paramete None Enumeration 10, 20, 50, 100, 20 10,20,50,100,200,5 ms
This
parameter
specifies the
length of an
EthOAM
PDU packet.
None Interval Typ 64~1024 64 to 1025 byte
Strech for
penalty of
Inter-Rat
handover
failure due to
physical
channel
failure. No try
of Inter-Rat
handover will
be taken until
penalty
finishes.
Also see
parameter
InterRatPhyC
hFailNum.
Inter-RAT Handov Interval Typ 0~65535 0~65535 s
Strech for
penalty of
Inter-Rat
handover
failure due to
physical
channel
failure. No try
of Inter-Rat
handover will
be taken until
penalty
finishes.
Also see
parameter
InterRatPhyC
hFailNum.
Inter-RAT Handov Interval Typ 0~65535 0~65535 s
Strech for
penalty of
Inter-Rat
handover
failure due to
physical
channel
failure. No try
of Inter-Rat
handover will
be taken until
penalty
finishes.
Also see
parameter
InterRatPhyC
hFailNum.
Inter-RAT Handov Interval Typ 0~65535 0~65535 s
Strech for
penalty of
Inter-Rat
handover
failure due to
physical
channel
failure. No try
of Inter-Rat
handover will
be taken until
penalty
finishes.
Also see
parameter
InterRatPhyC
hFailNum.
Inter-RAT Handov Interval Typ 0~65535 0~65535 s
parameter
aims to
prevent that
the handover
conditions are
not met and
the
compressed
mode is kept
for a long
time when the
UE does not
move or is
moving in a
low speed.
The service
quality is
adversely
affected and
the total
available
capacity
decreases if
the
compressed
mode is kept
for a long
time.
Most inter-
RAT
handovers can
be finished
within 60 s.
As for the Inter-RAT Handov Interval Typ 0~300 0~300 s
This parameter DCCC Enumeration D250, D500, D100 250, 500, 1000, 200 ms
This parameter DCCC Enumeration D250, D500, D100 250, 500, 1000, 200 ms
This parameter Radio Bearers Interval Typ 0~1000 0~1000 None
This parameter Radio Bearers Interval Typ 0~1000 0~1000 None
IP Path Ping P IP RAN Interval Typ 1~60 1~60 s
retry due to
inter-
frequency
handover
failure, and
the faster the
UE to be
successfully
handed over
this
to the target Inter-Frequency H Interval Typ 1~64 500~32000,Step:50 ms
parameter, the
more frequent
the handover
retry due to
inter-
frequency
handover
failure, and
the faster the
UE to be
successfully Inter-Frequency H Interval Typ 1~64 500~32000,Step:50 ms
the handover
handed over
retry due to
inter-RAT
handover
failure, and
the faster the
UE to be
successfully
handed over
to the target Inter-RAT Handov Interval Typ 1~64 500~32000,Step:50 ms
the handover
retry due to
inter-RAT
handover
failure, and
the faster the
UE to be
successfully
handed over
to the target Inter-RAT Handov Interval Typ 1~64 500~32000,Step:50 ms
This parameter Intra-Frequency H Enumeration D1, D2, D4, D8, 1, 2, 4, 8, 16, 32, None
This parameter Intra-Frequency H Enumeration D1, D2, D4, D8, 1, 2, 4, 8, 16, 32, None
This parameter Intra-Frequency H Enumeration D1, D2, D4, D8, 1, 2, 4, 8, 16, 32, None
PPP link multi None Enumeration Disable, Enable Disable(Not suppor None
This parameter Transmission Res Interval Typ 0~5 0 to 5 None
Uniquely ident None Interval Typ 0~255 0~255 None
upon which
the UE
behaviour is
not defined.
This
parameter has
impact on the
Uu signaling
flow. If the
interval is too Inter-Frequency H Enumeration NON_PERIODIC_RENON_PERIODIC_REPms
reports is the
short and the
configured Inter-Frequency H Enumeration NON_PERIODIC_RENON_PERIODIC_REPms
value.
The maximum nu Power Control Interval Typ 1~64 1~64 None
Sequence No. oNone Bit Field Ty SIGNATURE0, S SIGNATURE0, SIG None
Indicating whe Load Control Enumeration OFF, ON OFF, ON None
Indicating whe Load Control Enumeration OFF, ON OFF, ON None
Priority of rout IP RAN Enumeration HIGH, LOW HIGH, LOW None
Route
are priority.
no users in None Interval Typ 0~99 0~99 None
it within a
conversational None Enumeration HIGH(High priori HIGH, NORMAL, None
specified
> streaming > Load Control Enumeration ARP, TrafficClass ARP,TrafficClass None
interactive > Load Control
This parameter Interval Typ 0~7 0~7 None
This parameter Load Control Interval Typ 0~7 0~7 None
This parameter Load Control Interval Typ 0~7 0~7 None
This parameter Load Control Interval Typ 0~7 0~7 None
This parameter Load Control Interval Typ 0~7 0~7 None
This parameter UE Behaviors in I Interval Typ 2~30 2~30 min
10)CR2284R1
_SWITCH.in
section
8.6.6.28 of
TS25.331 of
R5 Before
2006, it
describes that
the HFN
should add
one when UE
is ciphering in
the situation
of Timing re-
initialized
hard
handover,whil
e not specified
in RB SETUP
process in the
section of
8.6.4.3. so it
is not clear
whether to
add or not in
RB SETUP in
DRD
scenarios.
CR2284R1
clarify that
HFN should
add one in RB
SETUP
process with Inter-RAT HandoveBit Field Ty INVOKE_TRACE_This parameter is se None
SS7 protocol
type
supported by
the DSP.
ITUT:
International
Telecommuni
cation Union -
Telecommuni
cation
Standardizatio
n Sector
ANSI:
American
National
Standards
Institute
TTC: THE
TELECOMM
UNICATION
TECHNOLO
GY
COMMITTE
E (use for
JAPAN).
The minimum reUE Behaviors in I Interval Typ -58~-13 -115~-25, step:2 dBm
This parameter Load Control Enumeration Band1, Band2, Ba Band1, Band2, Ban None
When the UL loLoad Control Interval Typ 0~100 0~100 per cent
When the load oLoad Control Interval Typ 0~100 0~100 per cent
RelThdForDw
nGrd: the
relative
threshold for
direct rate
reduction. It
can be
configured on
the BAM
server.
Note: The Intra-Frequency H Interval Typ -29~29 -14.5~14.5,Step:0.5 dB
smaller the
This parameter IP RAN String Type - 1 to 250 characters None
Resource mana Transmission Res Enumeration SHARE, EXCLUS SHARE, EXCLUSI None
Resource man Transmission Res Enumeration SHARE, EXCLUS SHARE, EXCLUSI None
Indicating th None Enumeration SHARE(Share), E SHARE, EXCLUSI None
Reason to loc None Enumeration COMMISSIONING(COMMISSIONING None
UNI: 5000~20000
No-Response TNone Interval Typ 1200~20000 NNI: 1200~20000 ms
CN reset
type.
1.
ALL_NODES
: resetting all
CN nodes
2. BY_CNID:
resetting the
CN nodes
specified by
[CN ID]
None Enumeration ALL_NODES, BY ALL_NODES,BY_ None
ON is open thi None Enumeration OFF, ON OFF, ON None
The times of r None Interval Typ 0~5 0~5 None
RNC Type to beNone Enumeration ALL_RNC, SING ALL_RNC,SINGL None
Reserved paramNone Bit Field Ty RsvdBit1_BIT1, R This parameter is se None
Reserved paramNone Bit Field Ty RsvdBit1_BIT1, R Each bit can be set None
Reserved paramNone Bit Field Ty RsvdBit1_BIT1, R Each bit can be set None
Parameter 1 res None Enumeration OFF, ON ON,OFF None
Reserved para Load Control Bit Field Ty RsvdBit1, RsvdBit RsvdBit1, RsvdBit2 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
Parameter 10 r None Interval Typ 0~4294967295 0 to 4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
This parameter None Interval Typ 0~4294967295 0~4294967295 None
Reserved paramNone Interval Typ 0~4294967295 0~4294967295 None
Reserved paramNone Interval Typ 0~4294967295 0~4294967295 None
Parameter 2 res None Enumeration OFF, ON ON,OFF None
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
This parameter DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
This parameter DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Traffic volume DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 byte
Time to trigge DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
It is used to None Interval Typ 0~100 0~100 per cent
It is used to None Interval Typ 0~100 0~100 per cent
When [RTO max None Interval Typ 1000~60000 1000~60000 ms
When [RTO max None Interval Typ 1000~60000 1000~60000 ms
When [RTO max None Interval Typ 1000~60000 1000~60000 ms
Route index, a None Interval Typ 0~4294967295 0~4294967295 None
Rate up step of Transmission Res Interval Typ 0~1000 0~1000 kbit/s
Period of rate Transmission Res Interval Typ 1~100 100~10000 ms
Backward bandTransmission Res Interval Typ 10~2810 530~148930 kbit/s
Backward bandw Transmission Res Interval Typ 1~3000000 1~3000000 kbit/s
This paramete Transmission Res Interval Typ 0~4000000 0~4000000 kbit/s
This parameter MBMS Service Enumeration D16, D32, D64, D 16, 32, 64, 128, 256 kbit/s
algorithm will
be applied.(If
cell-level
DRD
parameters are
configured, Load Control Enumeration ON, OFF ON, OFF None
the status of
Uniquely iden MBMS Service Interval Typ 0~4294967295 0~4294967295 None
Indicating whe None Enumeration SUPPORT_CS, S SUPPORT_CS, SU None
Indicating
whether the
SNAC need
be configured.
TRUE: The
SNAC need
be configured.
FALSE: The
SNAC need
not be
configured.U
E can access
any cell of the
PLMN.
IMSI-Based Hando Enumeration TRUE, FALSE TRUE,FALSE None
When it is set Inter-RAT Handov Enumeration OFF, ON OFF, ON None
BIT14: 1~16383
BIT16: 1~65535
BIT24:
The OSP shouldNone Interval Typ 1~16777215 1~16777215 None
Indicating the None Enumeration BIT14, BIT16, BI BIT14, BIT16, BIT None
The OSP shouldNone String Type - 1~11 characters None
triggered even Inter-Frequency H Enumeration ON(ON), OFF(OFFON,OFF
None
if this switch
Hysteresis use Load Control Interval Typ 0~100 0~1, step:0.01 per cent
power.
If the load of
a cell is equal
to or lower
than this
threshold, the
load level of
this cell is
light.
If the load
level of a cell
is light, the
PUC
algorithm will
configure
selection/resel Load Control Interval Typ 0~100 0~1, step:0.01 per cent
ection
The threshold Flow Control
preferably Interval Typ 40~100 40~100 per cent
carried on
in the RRC Radio Bearers, H Enumeration DCH(UL_DCH,DL DCH, HSDPA, HSP None
DCH, and
connection Radio Bearers, H Enumeration FALSE, TRUE FALSE, TRUE None
setup
SRB service do Iub Overbooking Interval Typ 0~100 0~100 per cent
Guaranteed ra HSPA+ Interval Typ 1~1000 1~1000 kbit/s
Maximum rate HSPA+ Interval Typ 1~2000 1~2000 kbit/s
SRB primary p Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
Signal bearing Transmission Res Interval Typ 0~100 0~100 None
SRB secondary Transmission Res Enumeration CBR, RT_VBR, NRCBR,RT_VBR,NRT_None
Signal primary Transmission Res Interval Typ 0~100 0~100 None
SRB service up Iub Overbooking Interval Typ 0~100 0~100 per cent
Source end of t None Interval Typ 0~31 0 to 31 None
Number of
the subrack
Value range:
0 to 5
Content: This
parameter
indicates the
number of the
subrack that
this command
applies to.
Recommende
d value
(default
value): none
None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter Transmission Res Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0~5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter Transmission Res Interval Typ 0~5 0~5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter Transmission Res Interval Typ 0~5 0~5 None
This parameter None Interval Typ 0~5 0~5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
This parameter None Interval Typ 0~5 0 to 5 None
No. of the WR None Interval Typ 0~5 0~5 None
Number of the None Interval Typ 0~5 0~5 None
This
parameter
specifies the
type of
source.
- SPEECH:
speech service
-
UNKNOWN:
non-speech
service
None Enumeration SPEECH, UNKN SPEECH, UNKNO None
This parameter None Interval Typ 20~99 20 to 99 per cent
This
parameter
specifies
whether the
NodeB
supports
setting of
DPC MODE
to TRIPLET.
- If this
parameter is
set to TRUE,
the NodeB
supports
setting of
DPC MODE
to TRIPLET.
- If this
parameter is
set to FALSE,
DPC MODE
is always
SINGLE.
Offset of cell
CPICH Ec/No
measurement
value in cell
selection or
reselection.
The larger the
value of the
parameter, the
lower the
probability of
selecting
neighboring
cells. The
smaller the
value the
parameter, the
higher the
probability of
doing so.
DL basic commo
Load Control, Iub Interval Typ 1~6000 10~60000, step:10 ms
This parameter Load Control, Iub Interval Typ 1~6000 10~60000, step:10 ms
HSDPA power rLoad Control, Iub Interval Typ 1~6000 10~60000, step:10 ms
This parameter Load Control Interval Typ 1~6000 10~60000, step:10 ms
Value range:
1~6000
Physical value
range: 10 to
60000, step:
10
Physical unit:
ms
Content: UL
basic common
measurement
report cycle.
For detailed
information of
this
parameter,
refer to 3GPP
TS 25.433.
Recommende
d value: 20
Load Control, Iub Interval Typ 1~6000 10~60000, step:10 ms
HCS cell
reselection
penalty timer.
The larger the
value of the
parameter, the
longer the
HCS penalty
time. The
smaller the
value of the
parameter, the
shorter the
HCS penalty
time.
UE Behaviors in I Enumeration D0, D10, D20, D30 0,10,20,30,40,50,60 s
This parameter HSDPA, HSUPA Enumeration CONVERSATION CONVERSATIONA None
This parameter Iub Overbooking, Enumeration INTERACTIVE, INTERACTIVE, None
This parameter Load Control Enumeration AMR, VP, PSR99, AMR,VP,PSR99,P None
This parameter Load Control Enumeration AMR, VP, PSR99, AMR,VP,PSR99,P None
M3UA_OVERRID
E_MOD,
M3UA_LOADSHA
RE_MOD
(For details of these
two modes, refer to
RFC4666.)
TrafficThis
action. mode None Enumeration M3UA_OVERRID None
parameter Load Control Interval Typ 0~10 0~10 None
defines the
This parameter IP RAN Interval Typ 0~65535 0~65535 ms
The transport Transmission Res Enumeration IP, HYBRID_IP IP, HYBRID_IP None
Transport type Transmission Res Enumeration ATM, IP, ATM_IP ATM,IP,ATM_IP,H None
Uniquely ident None Interval Typ 1~32 1~32 None
This parameter Radio Bearers Enumeration TRCH_HSDSCH, TRCH_HSDSCH, None
This parameter Radio Bearers Enumeration TRCH_DCH, TR TRCH_DCH, TRC None
This parameter Radio Bearers Enumeration TRCH_DCH, TRC TRCH_DCH, TRC None
restored to the
state when the
1st event 1D
occurs during
the latest
[TRELATEL Inter-Frequency H Interval Typ 0~120 0~120 s
ENGTH]. The
the non-soft-
switch area of
the cell and
that the UE
timely
performs
location
updates, cell
updates, or
URA updates
when
necessary.
2. Ensure that
the UE does
not reselect a
cell when it is
in the soft-
switch area of
the cell. In
this way, the
unnecessary
location
updates, cell
updates, and
URA updates
are avoided.
3. Consider
the difference
between cells
that cover
different
areas, for
example the
cells covering UE Behaviors in I Interval Typ 0~31 0~31 s
highways and URA Update, Cell Interval Typ 0~31,255
This parameter {0~6.2},{255}, step s
This parameter URA Update, Cell Interval Typ 0~31,255 {0~31},{255} s
Bearing timesl None Bit Field Ty TS1, TS2, TS3, TS TS1,TS2,TS3,TS4, None
Timeslot cross None Interval Typ 0~65535 0 to 65535 None
Name of the sc None String Type - 1~50 characters None
Time window
for deciding
whether the
UE is in low-
mobility state.
Every time
the slow
speed cycle
timer times
out, the RNC
estimates
whether the
UE is in low-
mobility state.
The backdated
time length is
set by this
parameter.
Duration when AMRC, AMRC-W Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when AMRC, AMRC-W Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when AMRC, AMRC-W Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when AMRC, AMRC-W Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
UL activity fa Load Control Interval Typ 0~100 0~1, step: 0.01 None
parameter, the
stronger the
smoothing Load Control, Iub Enumeration D0, D1, D2, D3, D D0, D1, D2, D3, D4 None
Duration when DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when DCCC Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Maximum UL rat DCCC Enumeration D8, D16, D32, D6 8, 16, 32, 64, 128, kbit/s
This parameter Load Control, DC Enumeration D0, D8, D16, D32 0, 8, 16, 32, 64, 128 kbit/s
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
Number of RABs
Load Control Interval Typ 1~10 1~10 None
Reserved SF th Load Control Enumeration SF4(SF4), SF8(SF SF4, SF8, SF16, SF None
This parameter Load Control Enumeration NoAct(no action), NoAct,InterFreqL None
Number of RABs
Load Control Interval Typ 1~10 1~10 None
If the ratio o Load Control Interval Typ 0~100 0~1, step:0.01 per cent
Threshold of t DCCC Enumeration D16, D32, D64, D 16, 32, 64, 128, 144 kbit/s
Length of smo Load Control, Iub Interval Typ 1~32 1~32 None
defines the
maximum
number of
RABs
selected in
executing
uplink OLC
fast
restriction.
Selection of
RABs of the
OLC is based
on the service
priorities and
ARP values
and bearing
priority
indication.
The RAB of
low priority is
under control.
In the actual
system,
UlOlcFTFRstr
ctRabNum
and
DlOlcFTFRstr
ctRabNum
can be set on
the basis of
the actual
circumstances
. If the high-
rate Load Control Interval Typ 1~10 1~10 None
defines the
maximum
number of
uplink OLC
fast TF
restriction
performed in
entering/exitin
g the OLC
status.
After the
overload is
triggered, the
RNC
immediately
executes OLC
by first
executing fast
TF restriction.
The internal
counter is
incremented
by 1 with each
execution. If
the number of
overloads
does not
exceed the
OLC action
threshold, the
system lowers
the BE service
rate by
lowering TF Load Control Interval Typ 0~100 0~100 None
L3 filtering co Load Control, Iub Enumeration D0, D1, D2, D3, D D0, D1, D2, D3, D4 None
If the ratio o Load Control Interval Typ 0~100 0~1, step:0.01 per cent
released in
Load Control Interval Typ 0~10 0~10 None
executing
UL OLC triggerLoad Control, Iub Interval Typ 1~6000 10~60000, step:10 None
If the ratio o Load Control Interval Typ 0~100 0~1, step:0.01 per cent
Duration when Inter-Frequency H Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when Inter-Frequency H Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Duration when Inter-Frequency H Enumeration D0, D10, D20, D4 0, 10, 20, 40, 60, 8 ms
Estimated
altitude of an
uncertain area
in the cell
center in the
WGS-84
coordinates.
This is
controlled by
MTRLGY
and valid
when
MET~0(metri
c system).
LCS Interval Typ 0~990 0~990 m
This
parameter
specifies the
estimated
altitude of an
uncertain area
in the cell
center in the
WGS-84
coordinates.
This is
controlled by
MTRLGY
and valid
when
IMP~1(British
measurement)
.
LCS Interval Typ 0~3248 0~3248 m
Length of the
semi-major
axis of an
uncertain area
in the cell
center.
This is
controlled by
MTRLGY
and valid
when
MET~0(metri
c system).
LCS Interval Typ 0~1800000 0~1800000 m
This
parameter
specifies the
length of the
semi-major
axis of an
uncertain area
in the cell
center.
This is
controlled by
MTRLGY
and valid
when
IMP~1(British
measurement)
.
LCS Interval Typ 0~5905440 0~5905440 m
Length of the
semi-minor
axis of an
uncertain area
in the cell
center.
This is
controlled by
MTRLGY
and valid
when
MET~0(metri
c system).
LCS Interval Typ 0~1800000 0~1800000 m
This
parameter
specifies the
length of the
semi-minor
axis of an
uncertain area
in the cell
center.
This is
controlled by
MTRLGY
and valid
when
IMP~1(British
measurement)
.
LCS Interval Typ 0~5905440 0~5905440 m
Number of the None Interval Typ 0~167 0 to 31(AEUa), 0 t None
This parameter MBMS Service Interval Typ 2~20 2~20 None
ID of the up IP RAN Interval Typ 0~1999 0~1999 None
Number of the Transmission Res Interval Typ 0~119 0~119 None
Type of the log Transmission Res Interval Typ 128~447 AEUa(128~191),AO None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
A cell can bel None Interval Typ 0~65535 0~65535 None
Indicating whe HCS Handover, UEEnumeration USED, NOT_USE USED, NOT_USED None
This parameter None Enumeration Disable, Enable Disable, Enable None
perform inter- Inter-RAT Handov Enumeration ALL_USER(All U
ALL_USER,HALF, None
RAT
Percentage of None Interval Typ 5~20 5~20 per cent
Percentage of None Interval Typ 50~100 50~100 per cent
This parameter Iub Overbooking, Enumeration GOLD, SILVER, GOLD, SILVER, C None
This paramete None Enumeration Disable, Enable Disable, Enable None
This parameter None Enumeration CELL/S, KBIT/S CELL/S, KBIT/S None
VCI of the PV Transmission Res Interval Typ 32~65535 32~65535 None
This parameter None Enumeration CC, LOOPBACK CC, LOOPBACK None
PPP
Link(ADD
PPPLNK)
Enable Enable MLPPP
Link, PPP
Link(ADD
MPLNK)
None Not involved Not involv
- 50 RNC None N (No impact on the UE in Not involv
- 100 RNC When [PARA]DsacA
N (No impact on the UE in Not involv
- AC0:BARRED,AC1: RNC When [PARA]DsacA
N (No impact on the UE in Not involv
10(SET
- DSACAUTOALGO) RNC
30(SET ACALGO) When [PARA]DsacA
N (No impact on the UE in Not involv
- 2 RNC None N (No impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Y Subsystem
- None RNC None N (No impact on the UE in Not involv
ACTIVE ACTIVE Cell Valid when [PA N (no impact on the UE in Not involv
- NODELIVERY RNC None N (no impact on the UE in Not involv
- UE_BASED RNC None N (no impact on the UE in Not involv
- None RNC
None Not involved Not involv
[/PARA] in
[MML]ADD
GPS[/MML] is
set to NODEB,
the cell ID, GPS
data report
period, DGPS
data report
period, AGPS
antenna latitude,
AGPS antenna
longitude, and
AGPS antenna
altitude should
be set.
1. When the
value of
[PARA]AGPSR
ECEIVERTYPE
[/PARA] in
[MML]ADD
GPS[/MML] is
set to
NRNC_RNC,
the RNC ID,
GPS data report
period, DGPS
data report
period, AGPS
antenna latitude,
AGPS antenna
longitude, and
AGPS antenna
- None RNC altitude should Not involved Not involv
-6 -6 Cell None N (Impact on acquisition i Not involv
1 1 Physical ch None Not involved Not involv
RNC(SET
BOXRPT,
SET
- None ALMLVL)
SRB(SET
ALMPOR
T)
None Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
- None Transmissio When [PARA]BWM N (No impact on the UE in Not involv
Automatic Automatic Cell None N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
Cell(ADD
4(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) 4
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
This parameter N (No impact on the UE in Not involv
1(ADD Cell(ADD
CELLINTE CELLINT
RFREQHO ERFREQH
NCOV) ONCOV)
1
-(SET RNC(SET
INTERFRE INTERFR
QHONCOV EQHONC
) OV)
None N (No impact on the UE in Not involv
4(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) 4 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
This parameter N (No impact on the UE in Not involv
Cell(ADD
1(ADD
CELLINT
CELLINTE
ERRATH
RRATHON
ONCOV)
COV) 1
RNC(SET
-(SET
INTERRA
INTERRAT
THONCO
HONCOV)
V)
None N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- NO RNC None N (no impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 100 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
- 200 RNC None N (No impact on the UE in Not involv
- 3000 RNC Valid when [PA N (no impact on the UE in Not involv
- None AAL2 Path When the value N (No impact on the UE in Services c
- None IP path None Not involved Not involv
- None Adjacent N When the value Not involved Not involv
Adjacent
Node(AD
D
ADJMAP,
ADD
ADJNOD
E)
AAL2
Path(ADD
AAL2PAT
H)
Services
carried on
- None the
network
element
with the
specific
ATM
address.
(ADD
AAL2RT)
IP
Path(ADD
IPPATHBI
ND,ADD
IPPATH)
PPP
Link(ADD
PPPLNK)
MLPPP
- None
Group,
PPP
Link(ADD
MPGRP)
When the value Y PPP link
PPP
Link(ADD
PPPLNK)
MLPPP
- None
Group,
PPP
Link(ADD
MPGRP)
None Y PPP link
PPP
Link(ADD
PPPLNK)
MLPPP
- None
Group,
PPP
Link(ADD
MPGRP)
None Y PPP link
PPP
Link(ADD
PPPLNK)
MLPPP
NO_V NO_V
Group,
PPP
Link(ADD
MPGRP)
None Not involved Not involv
- ENABLE Ethernet por When the value Y Port
7 7 Physical ch [PARA]AvailablesN (Impact on random acces Not involv
0 0 Physical ch [PARA]Available N (Impact on random acces Not involv
15 15 Physical ch None N (Impact on random acces Not involv
- None RNC None N (No impact on the UE in Not involv
- None SRB None Not involved Not involv
- None subrack When the value Y RNC
- None subrack When the value Y RNC
61 61 Cell None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None Ethernet por When the value Not involved Not involv
- None Ethernet por When the value Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
-(ADD
NRNCCEL
L,ADD
QUICKCEL None(ADD
LSETUP,A NRNCCELL,ADD
DD QUICKCELLSETUP
CELLSETU ,ADD CELLSETUP)
Cell
P)
GSM900_DCS1800_
GSM900_D BAND_USED(ADD
CS1800_B GSMCELL)
AND_USE
D(ADD
GSMCELL)
None Y Cell
- CONVERSATIONAL:RNC None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
-30 -30 Cell None N (No impact on the UE in Not involv
-20 -20 Transport c None N (Impact on cell system Not involv
- None RNC None Not involved Not involv
- None RNC None. N (No impact on the UE in Not involv
- D384 RNC None N (No impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
1[/PARA] is set
- RateDegrade RNC N (no impact on the UE in Not involv
to None; is not
1[/PARA]
- None RNC N (no impact on the UE in Not involv
set to None;must
3[/PARA]
- None RNC N (no impact on the UE in Not involv
not be equal with
- 5 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]BeH2FT
vmThd[/PARA]
<
[PARA]BeEFach
2CpcTvmThd[/P
ARA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]D2F2PT
vmThd[/PARA]
<
[PARA]BeEFach
2DTvmThd[/PA
RA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]BeH2FT
vmThd[/PARA]
<
[PARA]BeEFach
2HTvmThd[/PA
RA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
- D1024 RNC None N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]BeH2FT
vmThd[/PARA]
<
[PARA]BeF2Cp
cTvmThd[/PAR
A].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]D2F2PT
vmThd[/PARA]
<
[PARA]F2DTvm
Thd[/PARA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
- D1024 RNC None N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]BeH2FT
vmThd[/PARA]
<
[PARA]BeF2HT
vmThd[/PARA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
- 65535 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
- D1000 RNC None N (no impact on the UE in Not involv
- D64 RNC 2HTvmThd[/PA N (no impact on the UE in Not involv
RA];
- D5000 RNC None N (no impact on the UE in Not involv
- D1440 RNC None N (No impact on the UE in Not involv
- 20 RNC Valid when [PAR N (no impact on the UE in Not involv
10(ADD Cell(ADD
CELLDCC CELLDCC
C) 10 C)
-(SET RNC(SET
DCCC) DCCC) This parameter N (No impact on the UE in Not involv
- YES RNC None N (no impact on the UE in Not involv
- None RAB At least one of N (No impact on the UE in Not involv
- None RAB At least one of N (No impact on the UE in Not involv
- None RNC 1[/PARA] is set N (no impact on the UE in Not involv
to None; is not
1[/PARA]
- None RNC N (no impact on the UE in Not involv
set to None.must
3[/PARA]
- None RNC N (no impact on the UE in Not involv
not be equal with
- SINGLE RNC Valid when [PAR N (no impact on the UE in Not involv
- YES RNC Valid only when N (no impact on the UE in Not involv
- YES RNC Valid only when N (no impact on the UE in Not involv
- NO RNC Valid when [PAR N (no impact on the UE in Not involv
- 3000 RNC Valid when [PAR N (no impact on the UE in Not involv
3 3 Current BF When the value Not involved Not involv
32 32 Cell This parameter N (No impact on the UE in Not involv
512 512 Cell This parameter N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationshiprelati
onship:
[PARA]
[BgnAbnormalT
hd]>=[BgnUpdat
eThd][/PARA] .
100 100 Cell N (No impact on the UE in Not involv
120 120 Cell None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationshiprelati
onship:
[PARA]BgnEnd
Time[/PARA]
>[PARA]MBgn
StartTime[/PAR
A]
- 06&00&00 Cell N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationshiprelati
onship:
[PARA]BgnEnd
Time[/PARA]
>[PARA]MBgn
StartTime[/PAR
A]
- 01&00&00 Cell N (No impact on the UE in Not involv
ON ON Cell None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationshiprelati
onship:
[PARA]
[BgnAbnormalT
hd]>=[BgnUpdat
eThd][/PARA] .
5 5 Cell N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
Cell(ADD
-115(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
-115 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None Board None Not involved Not involv
- None Board None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
Cell(ADD
REQUIRED CELLINT
(ADD ERRATH
CELLINTE OCOV,AD
RRATHOC D
OV,ADD CELLINT
CELLINTE ERRATH
RRATHON REQUIRED ONCOV)
COV) RNC(SET
-(SET INTERRA
INTERRAT THOCOV,
HOCOV,SE SET
T INTERRA
INTERRAT THONCO
HONCOV) V)
None N (No impact on the UE in Not involv
REQUIRED REQUIRED Cell None N (No impact on the UE in Not involv
- None E1/T1 link None Not involved Not involv
- None Cell None Y Cell
- None E1T1 Link None Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None board None Y RNC
- None E1T1 link None Not involved Not involv
- None board None Not involved Not involv
- None RNC When the value Not involved Not involv
- None Correspondi None Not involved Not involv
- None LGC port None Transmission Resource M Not involv
OFF OFF LGC port When the value Not involved When the
PPP
Link(ADD
PPPLNK)
IMA
group(AD
D
IMAGRP)
Fractional
link(ADD
0 0 FRALNK)
UNILNK(
ADD
UNILNK)
MLPPP
Group,
PPP
Link(ADD
MPGRP)
PPP
Link(ADD
PPPLNK)
IMA
group(AD
D
IMAGRP)
Fractional
link(ADD
0 0 FRALNK)
UNILNK(
ADD
UNILNK)
MLPPP
Group,
PPP
Link(ADD
MPGRP)
0 0 UNILNK(
ADD
UNILNK)
Fractional
link(ADD
FRALNK)
IMA
group(AD
D
IMAGRP)
- None NodeB
None
[MML]ADD Not involved Not involv
IPOAPVC[/MM
L] is set to
IPoA NCORT, the
PVC(ADD CARRYNCOPT
IPOAPVC N is required.
) When the value
AAL2 of
Path(ADD [PARA]CARRY
- None AAL2PAT T[/PARA] in
H) [MML]ADD
AAL2PATH[/M
SAAL(AD ML] is set to
D NCOPT, this
SAALLN parameter is
K) valid.
When the value
of N (No impact on the UE in Not involv
- None LGC port [PARA]CARRY
None
AAL2PATH[/M Transmission Resource M Not involv
ML] is set to
AAL2 UNI, IMA,
Path(ADD FRAATM,
AAL2PAT NCOPT, or
H) ATM logic port,
- None this parameter is
SAAL(AD valid.
D When the value
SAALLN of
K) [PARA]CARRY
T[/PARA] is set Y AAL2 Path
- None SAAL to IMA,the
When UNI,
value Not involved Not involv
- None LGC port None Not involved Not involv
- None LGC port None Transmission Resource M Not involv
value of
[PARA]CARRY
T[/PARA] in
[MML]ADD
IPOAPVC[/MM
L] is set to UNI,
the bearing UNI
link number,
bearing VPI,
bearing VCI, TX
traffic record
AAL2 index, RX traffic
Path(ADD record index,
AAL2PAT and peer type are
H) required.
3. When the
SAAL(AD value of
- None D [PARA]CARRY
SAALLN T[/PARA] in
K) [MML]ADD
IPoA IPOAPVC[/MM
PVC(ADD L] is set to
IPOAPVC FRAATM, the
) bearing
FRAATM link
number, bearing
VPI, bearing
VCI, TX traffic
record index, RX
traffic record
index, and peer
type are
required.
4. When the
[MML]ADD Y AAL2 Path
value of
IPOAPVC[/MM
L] is set to UNI,
IPoA the
PVC(ADD CARRYUNILN
IPOAPVC KN is required.
) When the value
of
SAAL(AD [PARA]CARRY
- None D T[/PARA] is set
SAALLN to UNI, this
K) parameter is
AAL2 valid.
Path(ADD When the value
AAL2PAT of
H) [PARA]CARRY
T[/PARA] in
[MML]ADD N (No impact on the UE in Not involv
- None LGC port AAL2PATH[/M
None Transmission Resource M Not involv
SAAL(AD
D
SAALLN
- None K)
IPoA
PVC(ADD
IPOAPVC
)
When the value Y Services c
SAAL(AD
D
SAALLN
- None K)
IPoA
PVC(ADD
IPOAPVC
)
When the value Y Services c
- None Cell Valid when [PA N (no impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
MIXED_EN MIXED_ENVIRONMCell Valid when [PA N (no impact on the UE in Not involv
TU TU Cell None N (No impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
- 15 RNC None N (No impact on the UE in Not involv
SINGLE_HOSINGLE_HOST Cell None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
CELLMB
MSSA,AD
D
CELLEFA
CH,ADD
CELLCBS
SAC,ADD
CELLRLA
CTTIME,
ADD
SMLCCE
LL,ADD
CELLAM
RC,ADD
CELLDCC
C,ADD
CELLAM
- None
RCWB,A
DD
CELLSET
UP)
RNC(ADD
CELLMB
DRINTER
RAT,ADD
CELLMB
DRINTER
FREQ,AD
D
NRNCCE
LL,ADD
CELLHCS
HO,ADD The value of th Not involved Not involv
- None Cell None N (No impact on the UE in Not involv
- 10 RNC None N (No impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
ACTIVE ACTIVE Cell Valid when [PA N (no impact on the UE in Not involv
- UE_ASSISTED RNC None N (no impact on the UE in Not involv
SF8 SF8 Cell The value of t N (No impact on the UE in Not involv
- None Cell None N (no impact on the UE in Not involv
- None Cell
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]CellOve
rrunThd[/PARA]
>=
[PARA]CellUnd
errunThd[/PAR
A].
90 90 Cell N (No impact on the UE in Not involv
- 9 RNC None N (no impact on the UE in Not involv
- 180 RNC None N (no impact on the UE in Not involv
NOT_RESE NOT_RESERVED Cell None N (No impact on the UE in Not involv
NOT_RESE NOT_RESERVED Cell None N (No impact on the UE in Not involv
AFFECT AFFECT Cell None N (No impact on the UE in Not involv
AFFECT AFFECT Cell None N (No impact on the UE in Not involv
- 45 RNC None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]CellOve
rrunThd[/PARA]
>=
[PARA]CellUnd
errunThd[/PAR
A].
30 30 Cell N (No impact on the UE in Not involv
- None Cell
None Y Cell
- CFG_DL_BLIND_DERNC None N (no impact on the UE in Not involv
- 2 RNC None N (no impact on the UE in Not involv
- 5 RNC None N (no impact on the UE in Not involv
CONVOLUTCONVOLUTIONAL Transport c None Not involved Not involv
5 5 IP Path When the value N (no impact on services Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None Ethernet por None Not involved Not involv
NO NO SCTP None Y Services th
NO NO SCTP None Y Services th
CRC32 CRC32 SCTP None Y Services th
- None Ethernet por None Not involved Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
- TEN_MSEC RNC None N (No impact on the UE in Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
- TEN_MSEC RNC
None N (No impact on the UE in Not involv
TEN_MSE Cell(ADD
C(ADD CELLQU
CELLQUA ALITYME
LITYMEAS TEN_MSEC AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
TEN_MSE Cell(ADD
C(ADD CELLQU
CELLQUA ALITYME
LITYMEAS TEN_MSEC AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
TEN_MSE Cell(ADD
C(ADD CELLQU
CELLQUA ALITYME
LITYMEAS TEN_MSEC AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
TEN_MSE Cell(ADD
C(ADD CELLQU
CELLQUA ALITYME
LITYMEAS TEN_MSEC AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLSET
UP)
0 0
RNC(ADD
NRNCCE
LL)
None Y Cell
0 0 Cell None N (No impact on the UE in Not involv
0 0 Cell
None N(For the UE in idle mode, Not involv
- None LGC port When the value N (No impact on the UE in Not involv
- None RNC None Y RNC
FALSE FALSE Cell None Y Cell
UL_DL_BO UL_DL_BOTH NodeB None. N (No impact on the UE in Not involv
WALKING
_SPEED_A
Cell(ADD
ND_HOT_S
WALKING_SPEED CELLCM
POT_CELL
_AND_HOT_SPOT_ CF)
(ADD
CELL RNC(SET
CELLCMC
CMCF)
F)
-(SET
CMCF)
None N (No impact on the UE in Not involv
- CMCF_DL_HLS_SWIRNC None N (no impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- CMP_IU_IMS_PROCRNC None N (no impact on the UE in Not involv
RNC(RST
IU,RST
IURESOU
RCE,ADD
CNNODE,
ADD
CNDOMA
- None IN)
RAB(ADD
TYPRAB
BASIC,A
DD
CELLRLP
WR)
Cell(ADD
QUICKCE
LLSETUP,
ADD
GSMCEL
- None L,ADD
NRNCCE
LL)
(ADD
CELLSET
UP)
This paramter N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC
CZ,ADD None Not involved Not involv
index should be Not involved Not involv
- None CNOPER
set.
- None ATOR)
RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
255 255 RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
ON ON Cell None N (No impact on the UE in Not involv
3 3 Cell This paramter i
ancingDrdSwitc N (No impact on the UE in Not involv
h[/PARA]
RNC(SET
-(SET parameter is set
DRD)
DRD) to ON.
13 Cell(ADD
13(ADD If this parameter
CELLDR
CELLDRD) is set through
D) N (No impact on the UE in Not involv
both the
[MML]ADD
ancingDrdSwitc
h[/PARA]
RNC(SET
-(SET parameter is set
DRD)
DRD) to ON.
SF8 Cell(ADD
SF8(ADD If this parameter
CELLDR
CELLDRD) is set through
D) N (No impact on the UE in Not involv
both the
[MML]ADD
RNC(SET
-(SET
DRD)
DRD)
OFF Cell(ADD
OFF(ADD
CELLDR
CELLDRD)
D)
COEXIST_
MEAS_TH Cell(ADD
D_CHOICE CELLHO
COEXIST_MEAS_T
_INTERFR COMM)
HD_CHOICE_INTE
EQ(ADD RNC(SET
RFREQ
CELLHOC HOCOM
OMM) M)
-(SET
HOCOMM)
None N (No impact on the UE in Not involv
- 70 RNC None N (No impact on the UE in Not involv
20(ADD Cell(ADD
CELLDCC CELLDCC
C) 20 C)
-(SET RNC(SET
DCCC) DCCC) This parameter N (No impact on the UE in Not involv
- NON-SUPPORTING RNC When [PARA]MOC N (No impact on the UE in Not involv
2 2 SAAL When the value N (No impact on the UE in Not involv
30 30 SAAL When the value N (No impact on the UE in Not involv
10 10 SAAL When the value N (No impact on the UE in Not involv
15 IP:15; ATM:20 RNC The relationship N (No impact on the UE in Not involv
15 IP:15; ATM:20 RNC The relationship N (No impact on the UE in Not involv
15 IP:15; ATM:20 RNC The relationship N (No impact on the UE in Not involv
15 IP:15; ATM:25 RNC The relationship N (No impact on the UE in Not involv
2.The
25 25 RNC relationship
2.The N (No impact on the UE in Not involv
25 25 RNC between the
relationship N (No impact on the UE in Not involv
25 IP:25; ATM:30 RNC between the
The relationship N (No impact on the UE in Not involv
25 IP:25; ATM:30 RNC The relationship N (No impact on the UE in Not involv
25 IP:25; ATM:30 RNC The relationship N (No impact on the UE in Not involv
25 IP:25; ATM:50 RNC The relationship N (No impact on the UE in Not involv
2.The
50 50 RNC relationship
2.The N (No impact on the UE in Not involv
50 50 RNC between the
relationship N (No impact on the UE in Not involv
- None Cell between
None the N (No impact on the UE in Not involv
- Only_To_Inter_Frequ RNC None. N (No impact on the UE in Not involv
NOT_ALLO NOT_ALLOWED Cell This paramter i N (No impact on the UE in Not involv
NO NO RNC None Not involved Not involv
2 2 Cell None N(impact on Cell Selection Not involv
- 2 Cell This parameter N(impact on Cell Selection Not involv
0 0 Cell
Cell(ADD
CELLSET
UP)
CP1_not_Su
CP1_not_Supported
pported
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
8 8 Cell This parameter N (No impact on the UE in Not involv
UNAVAILA UNAVAILABLE SCTP None N (No impact on the UE in Not involv
100 100
transmission type is RNC None N (No impact on the UE in Not involv
- ATM, the parameter RNC When the value N (No impact on the UE in Not involv
100 is RT_VBR;
100 RNC None N (No impact on the UE in Not involv
parameter is
- RNC When the value N (No impact on the UE in Not involv
LQAF43.
0 0 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
This parameter
is valid when
[PARA]NcovHo
On2GldInd[/PA
Cell(ADD
80(ADD RA] in
CELLINT
CELLINTE [MML]SET
ERRATH
RRATHON INTERRATHO
ONCOV)
COV) 80 NCOV[/MML]
RNC(SET
-(SET is set to ON.
INTERRA
INTERRAT This parameter
THONCO
HONCOV) is valid when
V)
[PARA]NcovHo
On2GldInd[/PA
RA] is set to
ON.
N (No impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- 900 RNC CsInfoUpdTmr n N (No impact on the UE in Not involv
- SUPP_NONE RNC None N (No impact on the UE in Not involv
- None RNC CSNRILength neeN (No impact on the UE in Not involv
- TRUE RNC When [PARA]DsacA
N (No impact on the UE in Not involv
OFF OFF Cell None N (No impact on the UE in Not involv
100 100
transmission type is RNC None N (No impact on the UE in Not involv
- ATM, the parameter RNC When the value N (No impact on the UE in Not involv
100 is RT_VBR;
100 RNC None N (No impact on the UE in Not involv
- parameter is RNC When the value N (No impact on the UE in Not involv
LQAF43.
0 0 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
- CS_AMRC_SWITCH:RNC None N (no impact on the UE in Not involv
BIT4(ADD
SCCPCHB BIT4(ADD
ASIC) SCCPCHBASIC) Physical
BIT2(ADD BIT2(ADD channel
PRACHBA PRACHBASIC)
SIC)
None Not involved Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 50 RNC None N (No impact on the UE in Not involv
- None Transmissio None Not involved Not involv
- ON RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC This classified zo N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]D2F2PT
vmThd[/PARA]
<
[PARA]F2DTvm
Thd[/PARA];
[PARA]D2F2PT
vmThd[/PARA]
<
[PARA]BeEFach
2DTvmThd[/PA
RA].
- D64 RNC N (no impact on the UE in Not involv
- D1000 RNC None N (no impact on the UE in Not involv
- D5000 RNC None N (no impact on the UE in Not involv
- 30 RNC None N (no impact on the UE in Not involv
This parameter
is required when
the
[PARA]Qrxlevm
inExtSup[/PAR
A] parameter is
Cell(ADD set to TRUE but
CELLSEL not required
RESEL) when the
- None [PARA]Qrxlevm
RNC(ADD inExtSup[/PAR
NRNCCE A] parameter is
LL) set to FALSE.
This paramter is
valid only when
[PARA]Qrxlevm
inExtSup[/PAR
A] is set to
TRUE.
N(impact on Cell Selection Not involv
M3UA(A
DD
M3DE)
- None
RNC(ADD
M3LKS,A
DD
M3RT)
The [PARA]DEN Not involved Not involv
- None Ethernet por None Not involved Not involv
- None RNC None Not involved Not involv
Ethernet
port(PING
MAC)
- None
RNC(TRC
MAC)
None Not involved Not involv
1 1 Cell None N (No impact on the UE in Not involv
64(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 64 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- 10 RNC This paramter i N (No impact on the UE in Not involv
D6(SET LDM)
- RNC
D3(SET SATLDM) None N (No impact on the UE in Not involv
- D128 RNC None N (No impact on the UE in Not involv
RNC(SET
-(SET FRCCHLT
FRCCHLT YPEPARA
YPEPARA) D8 )
D8(ADD Cell(ADD
CELLFRC) CELLFRC
)
If this parame N (No impact on the UE in Not involv
- D64 RNC This parameter N (No impact on the UE in Not involv
- D64 RNC None. N (No impact on the UE in Not involv
64(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 64 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
64(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 64 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlOlcTr
igThd[/PARA]
(See
[MML]ADD
CELLLDM[/M
ML]) >=
[PARA]DlCellT
otalThd[/PARA]
;
[PARA]DlCellT
otalThd[/PARA]
>=
[PARA]DlHOTh
d[/PARA] .
90 90 Cell N (No impact on the UE in Not involv
SF/2 SF/2 NodeB None. N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DLOVS
FSF[/PARA]>=[
PARA]DLCOD
ENO[/PARA]. .
- None Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlHOTh
d[/PARA] >
[PARA]DlConv
AMRThd[/PAR
A];
[PARA]DlConv
AMRThd[/PAR
A] >
[PARA]DlOther
Thd[/PARA] .
80 80 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlHOTh
d[/PARA] >
[PARA]DlConv
NonAMRThd[/P
ARA];
[PARA]DlConv
NonAMRThd[/P
ARA] >
[PARA]DlOther
Thd[/PARA] .
80 80 Cell N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
3 3
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
3 3
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlHoCe
CodeResvSf[/PA
RA] >=
[PARA]DlLdrCr
editSfResThd[/P
ARA];
[PARA]DlHoCe
CodeResvSf[/PA
RA] >=
[PARA]CellLdr
SfResThd[/PAR
A] .
SF32 SF32 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlCellT
otalThd[/PARA]
>=
[PARA]DlHOTh
d[/PARA] ;
[PARA]DlHOTh
d[/PARA] >
[PARA]DlConv
AMRThd[/PAR
A];
[PARA]DlHOTh
d[/PARA] >
[PARA]DlConv
NonAMRThd[/P
ARA] .
- 5 RNC
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
SF8 SF8
NodeB(A
DD
NODEBL
DR)
The value of t N (No impact on the UE in Not involv
no action no action Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
CodeAdj(A Cell(ADD
DD CELLLDR
CodeAdj(ADD
CELLLDR) )
CELLLDR)
BE traff
BE traff rate
rate NodeB(A
reduction(ADD
reduction(A DD
NODEBLDR)
DD NODEBL
NODEBLD DR)
R)
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlLdrTr
igThd[/PARA]
>=
[PARA]DlLdrRe
lThd[/PARA];
[PARA]DlOlcRe
lThd[/PARA] >=
[PARA]DlLdrRe
lThd[/PARA].
60 60 Cell N (No impact on the UE in Not involv
inter-freq
Cell(ADD
load
CELLLDR
handover(A inter-freq load
)
DD handover(ADD
CELLLDR) CELLLDR)
NodeB(A
no no action(ADD
DD
action(ADD NODEBLDR)
NODEBL
NODEBLD
DR)
R)
None N (No impact on the UE in Not involv
no action no action Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
no action no action Cell None N (No impact on the UE in Not involv
BE traff
Cell(ADD
rate
CELLLDR
reduction(A BE traff rate
)
DD reduction(ADD
CELLLDR) CELLLDR)
NodeB(A
no no action(ADD
DD
action(ADD NODEBLDR)
NODEBL
NODEBLD
DR)
R)
None N (No impact on the UE in Not involv
[PARA]DlOlcTr
70 70 Cell N (No impact on the UE in Not involv
igThd[/PARA] >
1000 1000 Cell None N (No impact on the UE in Not involv
D64 D64 NodeB None. N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
D1(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D1 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- HAND_APPOINT RNC This parameter N (no impact on the UE in Not involv
This parameter
is valid when the
[PARA]DlMidR
ateCalc[/PARA]
in [MML]SET
DCCC[/MML] is
set to
HAND_APPOIN
T, and the
following
relationship must
be satisfied:
[PARA]DlDccc
RateThd[/PARA
] <=
[PARA]DlMidR
ateThd[/PARA].
- D128 RNC N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]UlMode
- 3000 RNC ChangeTimerLe
n[/PARA] <=
[PARA]DlMode
ChangeTimerLe
n[/PARA].
N (no impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
3 3 Cell None N (No impact on the UE in Not involv
3 3 Cell None N (No impact on the UE in Not involv
- D1 RNC
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlOlcTr
igThd[/PARA]
>=
[PARA]DlOlcRe
lThd[/PARA];
[PARA]DlOlcRe
lThd[/PARA] >=
[PARA]DlLdrRe
lThd[/PARA].
85 85 Cell N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
- 100 RNC
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlOlcTr
igThd[/PARA]
>=
[PARA]DlOlcRe
lThd[/PARA];
[PARA]DlOlcTr
igThd[/PARA] >
[PARA]DlLdrTr
igThd[/PARA];
[PARA]DlOlcTr
igThd[/PARA]
>=
[PARA]DlCellT
otalThd[/PARA].
The value of
this parameter
must satisfy the
following
relationship:
[PARA]DlConv
AMRThd[/PAR
A] >
[PARA]DlOther
Thd[/PARA];
[PARA]DlConv
NonAMRThd[/P
ARA] >
[PARA]DlOther
Thd[/PARA];
[PARA]DlOther
Thd[/PARA] >=
[PARA]DlLdrTr
igThd[/PARA]
(See
[MML]ADD
CELLLDM[/M
ML]).
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
20(ADD Cell(ADD
CELLQOS CELLQOS
HO) 20 HO)
-(SET RNC(SET
QOSHO) QOSHO) None N (No impact on the UE in Not involv
- NO RNC Valid when [PAR N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- 3_Rates RNC None N (no impact on the UE in Not involv
- 3_Rates RNC None N (no impact on the UE in Not involv
5(ADD Cell(ADD
CELLQOS CELLQOS
HO) 5 HO)
-(SET RNC(SET
QOSHO) QOSHO) None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
- FALSE RNC None N (No impact on the UE in Not involv
D64(ADD Cell(ADD
CELLCMC CELLCM
F) D64 CF)
-(SET RNC(SET
CMCF) CMCF) None N (No impact on the UE in Not involv
- 10 RNC This paramter i N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- D64 RNC None. N (No impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]DlThdE
1[/PARA] <=
- 50 RNC [PARA]DlThdE
2[/PARA] <
[PARA]DlThdF2
[/PARA] <=
[PARA]DlThdF1
[/PARA].
N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]DlThdE
1[/PARA] <=
- 50 RNC [PARA]DlThdE
2[/PARA] <
[PARA]DlThdF2
[/PARA] <=
[PARA]DlThdF1
[/PARA].
N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]DlThdE
1[/PARA] <=
- 120 RNC [PARA]DlThdE
2[/PARA] <
[PARA]DlThdF2
[/PARA] <=
[PARA]DlThdF1
[/PARA].
N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]DlThdE
1[/PARA] <=
- 120 RNC [PARA]DlThdE
2[/PARA] <
[PARA]DlThdF2
[/PARA] <=
[PARA]DlThdF1
[/PARA].
N (no impact on the UE in Not involv
80 80 Cell None N (No impact on the UE in Not involv
64(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 64 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
(53*8) >
- None IMA group N (No impact on the UE in Not involv
[PARA]DLYGB
- None RNC None N (No impact on the UE in Not involv
- None SRB None Not involved Not involv
- None RNC When the value o Y RNC
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC When the value o Y RNC
Cell(ADD
CELLSET
UP)
None None
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
Cell(ADD
CELLSET
UP)
None None
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
- SINGLE_TPC RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None Ethernet por None Not involved Not involv
N7DPC[/MML]
The parameter
[PARA]DPX[/P
ARA] in
RNC(ADD [MML]ADD
MTP3RT, N7DPC[/MML]
ADD When the value
NRNC,AD of
D [PARA]NODET
CNNODE, [/PARA] in
ADD [MML]ADD
MTP3LKS ADJNODE[/MM
,ADD L] is set to IUR,
- None
N7DPC) IUCS, or
NNI_AAL2SWI
M3UA(A TCH, or the
DD value of
M3DE) [PARA]NODET
Adjacent [/PARA] in
Node(AD [MML]ADD
D ADJNODE[/MM
ADJNOD L] is set to IUPS
E) and
[PARA]SGSNF
LG[/PARA] in
[MML]ADD Not involved Not involv
BOTH BOTH PVC When the value Not involved Not involv
O_SWITCH,DR
A_THROU_DC
CC_SWITCH,D
RA_BE_EDCH_
TTI_RECFG_S
WITCH and
DRA_HSUPA_
DCCC_SWITC
H are valid when
DRA_DCCC_S
WITCH is set to
ON;
For BE
service,DRA_HS
DPA_STATE_T
RANS_SWITCH
and
DRA_HSUPA_S
TATE_TRANS_
SWITCH are
valid when
DRA_PS_BE_S
TATE_TRANS_
SWITCH is set
to ON;
For RT
service,DRA_HS
DPA_STATE_T
RANS_SWITCH
and
DRA_HSUPA_S
TATE_TRANS_
SWITCH are
- DRA_AQM_SWITCH:RNC valid when N (no impact on the UE in Not involv
DRA_PS_NON_
-18 -18 Cell
None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
RNC(SET
-(SET
DRD)
DRD)
2 Cell(ADD
2(ADD
CELLDR
CELLDRD)
D) If this parame N (No impact on the UE in Not involv
- NO RNC Valid when [PAR N (no impact on the UE in Not involv
60 IP:60; ATM:45 RNC The relationship N (No impact on the UE in Not involv
60 IP:60; ATM:45 RNC The relationship N (No impact on the UE in Not involv
60 IP:60; ATM:45 RNC The relationship N (No impact on the UE in Not involv
60 IP:60; ATM:80 RNC The relationship N (No impact on the UE in Not involv
2.The
80 80 RNC relationship
2.The N (No impact on the UE in Not involv
80 80 RNC between the
relationship N (No impact on the UE in Not involv
- DR_RRC_DRD_SWITRNC between
None the N (no impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
6 6 RNC DRXCycleLenCo N (For the UE in idle mode,Not involv
- 6 RNC None N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
PPP
Link(ADD
PPPLNK)
- None
MLPPP
Link(ADD
MPLNK)
None Not involved Not involv
- ON RNC None N (No impact on the UE in Not involv
Ethernet
port(PING
IP)
RNC(SET
0(PING IP) DSCPMA
0(PING IP)
-(SET P)
None(SET
PHBMAP,S
PHBMAP,SET
ET SCTP(AD
DSCPMAP)
DSCPMAP) D
62(ADD
62(ADD SCTPLNK
SCTPLNK)
SCTPLNK) )
Board(SE
T
PHBMAP)
None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None RNC None Y RNC
- None E1/T1 None N (No impact on the UE in Not involv
IP
Route(AD
D IPRT)
- None
RNC(ADD
IPRTBIN
D)
Nonenot be the
must Not involved Not involv
- None RNC same as any IP Not involved Not involv
- None IP Route address
None that has Not involved Not involv
- None IP Route None Not involved Not involv
- None E1/T1 None N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- Full Ethernet por When the value N (No impact on the UE in Port
- 20 RNC This paramter i N (No impact on the UE in Not involv
- 180 RNC This paramter i N (No impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
CONDITIO CONDITIONALSHU Cell This paramter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 30 RNC None N (no impact on the UE in Not involv
- 4 RNC None N (no impact on the UE in Not involv
- 8 RNC None N (no impact on the UE in Not involv
- 2 RNC None N (no impact on the UE in Not involv
1 1 Cell None N (No impact on the UE in Not involv
- None IP Path When the value N (no impact on services Not involv
- 500 RNC None N (no impact on the UE in Not involv
- 100 RNC None N (no impact on the UE in Not involv
-(SET RNC(SET
FRC) FRC)
30000 Cell(ADD
30000(ADD CELLFRC
CELLFRC) ) If this parame N (No impact on the UE in Not involv
- 3000 RNC None N (no impact on the UE in Not involv
- 5000 RNC None N (no impact on the UE in Not involv
RNC(SET
-(SET
FRC)
FRC)
41 Cell(ADD
41(ADD
CELLFRC
CELLFRC)
) If this parame N (No impact on the UE in Not involv
- None RNC When the value Y RNC
336 336 RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter N (No impact on the UE in Not involv
- None RAB This parameter N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
D1 D1 RAB This parameter N (No impact on the UE in Not involv
16 16 RAB None. N (No impact on the UE in Not involv
16 16 RAB None. N (No impact on the UE in Not involv
RATE_256KBPS:
- RNC None N (no impact on the UE in Not involv
selected
- None RAB This parameter N (No impact on the UE in Not involv
This parameter
is required when
the
[PARA]TrchTyp
e[/PARA]
parameter is set
to
TRCH_EDCH_2
MS or
TRCH_EDCH_1
0MS.
This parameter is
must larger than
[PARA]EdchTar
getLittleRetrans
Num[/PARA].
- None RAB N (No impact on the UE in Not involv
This parameter
is required when
the
[PARA]TrchTyp
e[/PARA]
parameter is set
to
TRCH_EDCH_2
MS or
TRCH_EDCH_1
0MS.
This parameter is
must less than
[PARA]EdchTar
getLargeRetrans
Num[/PARA].
- None RAB N (No impact on the UE in Not involv
2 2 RAB None. N (No impact on the UE in Not involv
2 2 RAB None. N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
20 20 RNC None N (No impact on the UE in Not involv
10 10 Cell None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- FALSE RNC None N (No impact on the UE in Not involv
- None RNC When the value Y RNC
- ON RNC None N (No impact on the UE in Not involv
OFF OFF RNC None Not involved Not involv
- OFF RNC None N (no impact on the UE in Not involv
- OCT RNC When the value Y RNC
- None RNC None N (No impact on the UE in Not involv
- UEA0-1; UEA1-1 RNC None N (No impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- None RNC
Negotiation with Not involved Not involv
1 1 Ethernet por None Not involved Not involv
1 1 Ethernet por None Not involved Not involv
1 1 Ethernet por None Not involved Not involv
204800 204800 Ethernet por None Not involved Not involv
1 1 Ethernet por None Not involved Not involv
60 60 Ethernet por None Not involved Not involv
1 1 Cell None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 7000 RNC None N (No impact on the UE in Not involv
- 03&00&00 RNC When the value Y RNC
D1024 D1024 RAB The value of thi N (No impact on the UE in Not involv
- None RAB The value of thi N (No impact on the UE in Not involv
50 50 RAB This parameter N (No impact on the UE in Not involv
160 160 RAB This parameter N (No impact on the UE in Not involv
80 80 RAB This parameter N (No impact on the UE in Not involv
- SUN RNC When the value Y RNC
- LAST RNC When the value Y RNC
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- D16000 RNC None N (no impact on the UE in Not involv
- D5000 RNC None N (no impact on the UE in Not involv
- None Transport c None Not involved Not involv
- None Cell This paramete Not involved Not involv
10(ADD Cell(ADD
CELLMBM 10(ADD CELLMB
SFACH) CELLMBMSFACH) MSFACH)
-(SET None(SET RNC(SET
MSCHFAC MBMSFACH) MSCHFA
H,SET -30(SET CH,SET
MBMSFAC MSCHFACH) MBMSFA
H) CH)
None Not involved Not involv
REQUIRE REQUIRE Cell This parameter N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None. N (No impact on the UE in Not involv
- 4 RNC None N (no impact on the UE in Not involv
- It must be consistent Ethernet por
FRALNK) of When the value N (No impact on the UE in Not involv
IMA [PARA]FLOWC
group(AD TRLSWITCH[/P
D ARA] in
IMAGRP) [MML]SET
OPT[/MML] is
Correspon set to ON, the
1(ADD ding flow control
ATMLOGI optical parameter index
CPORT,AD port(SET should be set.
D OPT) When the value
1(ADD
UNILNK,A Ethernet of
ATMLOGICPORT,
DD port(SET [PARA]FLOWC
ADD UNILNK,SET
IMAGRP,A ETHPORT TRLSWITCH[/P
OPT,ADD
DD ) ARA] is set to
IMAGRP,ADD
FRALNK) MLPPP ON in
FRALNK)
-(ADD Group, [MML]SET
None(ADD
PORTFLO PPP ETHPORT[/MM
PORTFLOWCTRLP
WCTRLPA Link(ADD L], the
ARA,SET
RA,SET PPPLNK, FCINDEX
ETHPORT)
ETHPORT, ADD should be set.
0(ADD
SET OPT) MPGRP) 1.When the
IPLOGICPORT,AD
0(ADD value of
D PPPLNK,ADD
IPLOGICP UNILNK( [PARA]FLOWC
MPGRP)
ORT,ADD ADD TRLSWITCH[/P
PPPLNK,A UNILNK) ARA] in
DD LGC [MML]ADD
MPGRP) port(ADD IPLOGICPORT[
IPLOGICP /MML] is set to
ORT,ADD ON, this
ATMLOG parameter should
ICPORT) be set.
2.The type of the
RNC(ADD flow control N (No impact on the UE in Not involv
PORTFLO parameter index
PPP
Link(ADD
PPPLNK)
16bit 16bit MLPPP
Link, PPP
Link(ADD
MPLNK)
None Y PPP link
- STEPSIZE_1DB RNC None N (No impact on the UE in Not involv
Cell(ADD
CELLSET
UP)
None None
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
Cell(ADD
CELLSET
UP)
None None
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
- -30 RNC None N (No impact on the UE in Not involv
- -200 RNC None N (No impact on the UE in Not involv
- 12 RNC None. N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
CFGMML-RNCX-
YYYYMMDDHHM
- MSS.txt(EXP RNC
CFGMML)
None(BKP DB) None Not involved Not involv
- None RNC None Not involved Not involv
- D3 RNC None N (No impact on the UE in Not involv
D3(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) D3 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
- None RNC
None Not involved Not involv
parameter index
- None Fractional l N (No impact on the UE in Not involv
are required.
D128 D128 IMA group None N (No impact on the UE in Not involv
- None Adjacent N The factor tabl N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
<
[PARA]FWDCO
NGCLRBW[/PA
RA] <
PPP
[PARA]MINBW
Link(ADD
[/PARA] or
PPPLNK)
[PARA]FWDHO
MLPPP
RSVBW[/PARA
Group,
]=
PPP
[PARA]FWDCO
Link(ADD
NGBW[/PARA]
MPGRP)
=
Fractional
[PARA]FWDCO
link(ADD
NGCLRBW[/PA
FRALNK)
RA] = 0.
0 0 IMA
If
group(AD
[PARA]BWADJ
D
[/PARA] is set to
IMAGRP)
be OFF,
[PARA]FWDHO
UNILNK(
RSVBW[/PARA
ADD
],
UNILNK)
[PARA]FWDCO
LGC
NGBW[/PARA],
port(ADD
[PARA]FWDCO
IPLOGICP
NGCLRBW[/PA
ORT)
RA] must obey
the following
rules: Not involved Not involv
0 0 LGC port [PARA]FWDHO
None Transmission Resource M Not involv
0 0 AAL2 Path None N (No impact on the UE in Not involv
0 0 IP Path [PARA]FWDHORN (no impact on the UE in Not involv
0 0 Transmissio [PARA]FWDHORN (No impact on the UE in Not involv
PPP
Link(ADD
PPPLNK)
MLPPP
Group,
PPP
Link(ADD
MPGRP)
Fractional
0 0 link(ADD
FRALNK)
IMA
group(AD
D
IMAGRP)
UNILNK(
ADD
UNILNK)
This paramter is
Cell(ADD
valid only when
GSMCEL
[PARA]UseOfH
L,ADD
cs[/PARA] is set
CELLHCS
to USED.
0 0 )
This paramter is
valid only when
RNC(ADD
[PARA]UseOfH
NRNCCE
cs[/PARA] is set
LL)
to TRUE.
N (No impact on the UE in Not involv
100 100
type is dual stack or RNC None N (No impact on the UE in Not involv
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
30 parameter is
30 RNC None N (No impact on the UE in Not involv
parameter is UBR;
- RNC When the value N (No impact on the UE in Not involv
transimssion type is
100 100 RNC None N (No impact on the UE in Not involv
70 70
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is AF33. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is AF43;
- transimssion type is RNC When the value N (No impact on the UE in Not involv
0 0Hybird IP, the RNC None N (No impact on the UE in Not involv
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
100 100
type is dual stack or RNC None N (No impact on the UE in Not involv
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
parameter
parameter isis UBR;
- type is dual stack RNC When the value N (No impact on the UE in Not involv
transimssion type or
is
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
parameter
parameter isis UBR;
- type RNC When the value N (No impact on the UE in Not involv
transimssionstack
is dual type or
is
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
- parameter
parameter isis UBR; RNC When the value N (No impact on the UE in Not involv
transimssion type is
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
15 15
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is EF;
- RNC When the value N (No impact on the UE in Not involv
transimssion type is
0 0 RNC None N (No impact on the UE in Not involv
50 50
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is EF;
- RNC When the value N (No impact on the UE in Not involv
transimssion type is
0 0 RNC None N (No impact on the UE in Not involv
100 100
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is AF33. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is AF43;
- transimssion type is RNC When the value N (No impact on the UE in Not involv
0 0Hybird IP, the RNC None N (No impact on the UE in Not involv
70 70
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter
parameter isis AF33.
AF43; RNC When the value N (No impact on the UE in Not involv
- When the interface
transimssion type is RNC When the value N (No impact on the UE in Not involv
- Hybird IP, the
None RNC When the value Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC When the value Not involved Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
2 2 Cell None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
SingleHost SingleHost NodeB None N (No impact on the UE in Not involv
- HO_ALGO_HCS_SPERNC None N (no impact on the UE in Not involv
-16 -16 RNC None N (No impact on the UE in Not involv
-92 -92 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- None RNC When the value Not involved Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
30 30 Cell None N (No impact on the UE in Not involv
- TRUE RNC None N (No impact on the UE in Not involv
- 50 RNC This paramter i N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
- 100 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
70 70 Cell None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
0 0 Cell This paramter i N (No impact on the UE in Not involv
336 336 RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter i N (No impact on the UE in Not involv
- None RAB This parameter N (No impact on the UE in Not involv
- None RAB This parameter N (No impact on the UE in Not involv
D1 D1 RAB This parameter N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
E_F_DPCH_ E_F_DPCH_OFF Cell None N (No impact on the UE in Not involv
- MIMO RNC None N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC 1.This parameter N (No impact on the UE in Not involv
- None RNC 1.This parameter N (No impact on the UE in Not involv
5 5 Cell This paramter i N (No impact on the UE in Not involv
This paramter is
valid only when
[PARA]AllocCo
deMode[/PARA]
is set to
Automatic and
the value of this
parameter must
satisfy the
following
relationship:
[PARA]HsPdsch
MaxCodeNum[/
PARA] >=
[PARA]HsPdsch
MinCodeNum[/P
ARA].
5 5 Cell N (No impact on the UE in Not involv
This paramter is
valid only when
[PARA]AllocCo
deMode[/PARA]
is set to
Automatic and
the value of this
parameter must
satisfy the
following
relationship:
[PARA]HsPdsch
MaxCodeNum[/
PARA] >=
[PARA]HsPdsch
MinCodeNum[/P
ARA].
1 1 Cell N (No impact on the UE in Not involv
2.5dB 2.5dB Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLSET
UP)
None None
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
- None RNC None Not involved Not involv
4 4 Cell None N (No impact on the UE in Not involv
- D100 RNC None N (No impact on the UE in Not involv
- D50 RNC None N (No impact on the UE in Not involv
- D100 RNC None N (No impact on the UE in Not involv
- D50 RNC None N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- D5760 RNC None N (no impact on the UE in Not involv
MBR MBR NodeB None N (No impact on the UE in Not involv
- BasedOnUECap RNC None N (No impact on the UE in Not involv
- 50 RNC This paramter i N (No impact on the UE in Not involv
- RATE_UP_AND_DORNC This paramete N (no impact on the UE in Not involv
100 100 Cell None N (No impact on the UE in Not involv
100 100 Cell None N (No impact on the UE in Not involv
- D256 RNC This parameter N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
100 100 Cell None N (No impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 100 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]HsupAu
RetrnsLdTrigTh
d[/PARA] >=
[PARA]HsupAu
RetrnsLdRelThd
[/PARA].
50 50 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]HsupAu
RetrnsLdTrigTh
d[/PARA] >=
[PARA]HsupAu
RetrnsLdRelThd
[/PARA].
70 70 Cell N (No impact on the UE in Not involv
0 0type is dual stack or Cell This paramter i N (No impact on the UE in Not involv
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
30 parameter is
30 RNC None N (No impact on the UE in Not involv
- parameter is UBR; RNC When the value N (No impact on the UE in Not involv
transimssion type is
100 100 RNC None N (No impact on the UE in Not involv
100 100
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is AF33. RNC When the value N (No impact on the UE in Not involv
100 When
100 the interface RNC None N (No impact on the UE in Not involv
parameter is AF43;
- transimssion type is RNC When the value N (No impact on the UE in Not involv
0 0Hybird IP, the RNC None N (No impact on the UE in Not involv
70 70 RNC None N (No impact on the UE in Not involv
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
100 100
type is dual stack or RNC None N (No impact on the UE in Not involv
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
parameter
parameter is
is UBR;
- type is dual stack RNC When the value N (No impact on the UE in Not involv
transimssion type or
is
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
parameter
parameter is
is UBR;
- type is dual stack RNC When the value N (No impact on the UE in Not involv
transimssion type or
is
- Hybird IP, the RNC When the value N (No impact on the UE in Not involv
parameter
parameter is
is UBR;
- RNC When the value N (No impact on the UE in Not involv
transimssion type is
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
- None
IP or Hybird IP, the RNC When the value Not involved Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is EF;
- RNC When the value N (No impact on the UE in Not involv
transimssion type is
0 0 RNC None N (No impact on the UE in Not involv
15 15
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
- parameter is EF; RNC When the value N (No impact on the UE in Not involv
transimssion type is
0 0 RNC None N (No impact on the UE in Not involv
50 50
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is AF33. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
parameter is AF43;
- transimssion type is RNC When the value N (No impact on the UE in Not involv
0 0Hybird IP, the RNC None N (No impact on the UE in Not involv
100 100
IP or Hybird IP, the RNC None N (No impact on the UE in Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
- parameter is EF;
When the interface RNC When the value N (No impact on the UE in Not involv
transimssion type is
70 70 RNC None N (No impact on the UE in Not involv
- None RNC When the value Not involved Not involv
- None RNC None Not involved Not involv
Cell(ADD
0(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
0 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
Cell(ADD
0(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
0 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
8(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
8 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
8(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
8 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
8(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
8 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
8(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
8 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
4(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) 4
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
This parameter N (No impact on the UE in Not involv
6(ADD Cell(ADD
CELLINTE CELLINT
RFREQHO ERFREQH
NCOV) ONCOV)
6
-(SET RNC(SET
INTERFRE INTERFR
QHONCOV EQHONC
) OV)
None N (No impact on the UE in Not involv
6 6 RNC None N (No impact on the UE in Not involv
Cell(ADD
4(ADD CELLINT
CELLINTE ERRATH
RRATHOC OCOV,AD
OV,ADD D
CELLINTE CELLINT
RFREQHO ERFREQH
COV) 4 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV,SE THOCOV,
T SET
INTERFRE INTERFR
QHOCOV) EQHOCO
V)
Cell(ADD
0(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) 0
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
This parameter N (No impact on the UE in Not involv
0 0 RNC None N (No impact on the UE in Not involv
- 720 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
64 64 IP Path When the value N (no impact on services Not involv
- None RNC None Not involved Not involv
- None Cell None N (No impact on the UE in Not involv
ALLOWED ALLOWED Cell This paramter i N (No impact on the UE in Not involv
2 2 Cell None N(impact on Cell Selection Not involv
- 2 Cell This parameter N(impact on Cell Selection Not involv
0 0 Cell
This parameter N(For the UE in idle mode, Not involv
0 0 Cell
This parameter N(For the UE in idle mode, Not involv
127 127 Cell None N(impact on Cell Selection Not involv
127 127 Cell None N(impact on Cell Selection Not involv
D320 D320 Cell This paramter i N (No impact on the UE in Not involv
UNI: 15000
- NNI: 500 SAAL None N (No impact on the UE in Not involv
- 30 RNC None N (No impact on the UE in Not involv
- 20000 RNC None N (No impact on the UE in Not involv
IMA
group(AD
D
IMALNK,
ADD
IMAGRP)
- None Fractional
link(ADD
FRALNK)
RNC(RM
V
IMAGRP)
None Not involved Not involv
- None IMA group None N (No impact on the UE in Not involv
Cell(ADD
-14(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) -14
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
Cell(ADD
60(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
ONCOV,A
NCOV,AD
DD
D
CELLINT
CELLINTE
ERFREQH
RFREQHO
60 OCOV)
COV)
RNC(SET
-(SET
INTERFR
INTERFRE
EQHONC
QHONCOV
OV,SET
,SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
None N (No impact on the UE in Not involv
3 3 RNC None N (No impact on the UE in Not involv
- OFF Sub System None N (No impact on the UE in Not involv
- -16 RNC None N (No impact on the UE in Not involv
Cell(ADD
-14(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) -14
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
-97(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) -97 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
The value of th N (No impact on the UE in Not involv
60 60 RNC This parameter N (No impact on the UE in Not involv
Cell(ADD
D3(ADD
CELLINT
CELLINTE
ERRATH
RRATHON
ONCOV,A
COV,ADD
DD
CELLINTE
CELLINT
RRATHOC
ERRATH
OV) D3
OCOV)
-(SET
RNC(SET
INTERRAT
INTERRA
HONCOV,S
THONCO
ET
V,SET
INTERRAT
INTERRA
HOCOV)
THOCOV)
Cell(ADD
16(ADD
CELLINT
CELLINTE
ERRATH
RRATHON
ONCOV)
COV) 16
RNC(SET
-(SET
INTERRA
INTERRAT
THONCO
HONCOV)
V)
None N (No impact on the UE in Not involv
- YES RNC This parameter N (no impact on the UE in Not involv
21 21 RNC None N (No impact on the UE in Not involv
- DRD RNC This parameter N (no impact on the UE in Not involv
-15(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) -15 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
-107(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) -107 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
This parameter N (No impact on the UE in Not involv
Cell(ADD
60(ADD
CELLINT
CELLINTE
ERRATH
RRATHON
ONCOV,A
COV,ADD
DD
CELLINTE
CELLINT
RRATHOC
ERRATH
OV) 60
OCOV)
-(SET
RNC(SET
INTERRAT
INTERRA
HONCOV,S
THONCO
ET
V,SET
INTERRAT
INTERRA
HOCOV)
THOCOV)
0(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) 0 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
None N (No impact on the UE in Not involv
0(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) 0 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
None N (No impact on the UE in Not involv
-15(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) -15 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
-107(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) -107 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
The value of th N (No impact on the UE in Not involv
PERIODIC
Cell(ADD
AL_REPOR
CELLINT
TING(ADD
ERRATH
CELLINTE PERIODICAL_REP
OCOV)
RRATHOC ORTING
RNC(SET
OV)
INTERRA
-(SET
THOCOV)
INTERRAT
HOCOV)
Cell(ADD
CPICH_EC/
CELLINT
NO(ADD
RAFREQ
CELLINTR
CPICH_EC/NO HO)
AFREQHO)
RNC(SET
-(SET
INTRAFR
INTRAFRE
EQHO)
QHO)
None N (No impact on the UE in Not involv
- OFF Sub System None N (No impact on the UE in Not involv
- 12 RNC This parameter N (no impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
Cell(ADD relationship:
6(ADD
CELLINT ([PARA]IntraRel
CELLINTR
RAFREQ ThdFor1ACSNV
AFREQHO)
6 HO) P[/PARA] -
-(SET
RNC(SET [PARA]Hystfor1
INTRAFRE
INTRAFR A[/PARA] / 2) <
QHO)
EQHO) ([PARA]IntraRel
ThdFor1BCSNV
P[/PARA] +
[PARA]Hystfor1
B[/PARA] / 2).
Ethernet
port(ADD
ETHTRKI
P)
- None
RNC(RM
V
ETHTRKI
P)
None Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None NodeB The parameter s N (No impact on the UE in Not involv
- None Ethernet por When the value Not involved Not involv
Ethernet
port(ADD
ETHTRKI
P)
- None
RNC(RM
V
ETHTRKI
P)
When the value Not involved Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NOT_BARR NOT_BARRED Cell None N (No impact on the UE in Not involv
NO NO Ethernet por None Not involved Not involv
- None Transmissio None Not involved Not involv
- None RNC
None Not involved Not involv
- 1 RNC None N (No impact on the UE in Not involv
1 1 NodeB None N (No impact on the UE in Not involv
1 1 NodeB None N (No impact on the UE in Not involv
- 300 RNC None N (No impact on the UE in Not involv
- 300 RNC None N (No impact on the UE in Not involv
OFF OFF RNC None N (No impact on the UE in Not involv
- TRUE RNC None N (No impact on the UE in Not involv
OFF OFF RNC None N (No impact on the UE in Not involv
OFF OFF RNC None N (No impact on the UE in Not involv
- None RAB None Not involved Not involv
- 16 byte Correspondi None Y Port
- SBS 155 Correspondi When the value o Y Port
- 16 byte Correspondi None Y Port
- SBS 155 Correspondi When the value o Y Port
- 16 byte Correspondi None Y Port
- SBS 155 Correspondi When the value o Y Port
- 16 byte Correspondi None Y Port
- SBS 155 Correspondi When the value o Y Port
- 32 RNC
None N (No impact on the UE in Not involv
None.
If this parameter
is set through
both the
[MML]ADD
CELLDRD[/MM
L] and
[MML]SET
-(SET
RNC(SET DRD[/MML]
DRD)
DRD) commands, the
UserNumber Cell(ADD parameter set
UserNumbe
CELLDR through the
r(ADD
D) [MML]ADD
CELLDRD)
CELLDRD[/MM
L] command
takes precedence
over that set
through the
[MML]SET
DRD[/MML]
command.
This is a
parameter in
RNC(ADD [MML]ADD
M3LE) OPC[/MML].
- None The
M3UA(A [PARA]LENO[/
DD PARA] field in
M3DE) [MML]ADD
M3LE[/MML]
Not involved Not involv
0 0 Ethernet por None Not involved Not involv
- ON RNC None Not involved Not involv
- None RNC When the value Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None Board None Not involved Not involv
- None Board None Not involved Not involv
- None RNC When the value Not involved Not involv
- D8 RNC This paramter i N (No impact on the UE in Not involv
- D64 RNC The low activit N (no impact on the UE in Not involv
- None SRB None Not involved Not involv
- None E1T1 link When the valu Not involved Not involv
POUa, the value
range of
[PARA]LNKN[/
PARA] is 0 to
167.
When the value
of
[PARA]BT[/PA
RA] in
[MML]STR
E1/T1
E1T1TST[/MM
link(SET
L] is set to
E1T1LOP)
AEUa or PEUa,
Cell(LOP
the link number
E1T1)
is required and
E1T1
the value range
Link(STR
is from 0 to 31.
- None E1T1TST)
When the value
E1T1
of
link(SET
[PARA]BT[/PA
E1T1)
RA] in
Optical
[MML]STR
Port(SET
E1T1TST[/MM
COPTLN
L] is set to
K)
AOUa or POUa,
the link number
is required and
the value range
is from 0 to 167.
When the value
of
[PARA]LS[/PA
RA] in
[MML]SET N (No impact on the UE in Not involv
Communic
ation
- None Link(ACT
VCLCC)
VCL(LOP
VCL)
None Not involved Not involv
- None RNC The parameter muNot involved Not involv
- None MLPPP Gro None N (No impact on the UE in Not involv
- None Ethernet por None Not involved Not involv
- None NodeB
None Y Cell
- None SCTP None Y Services th
- None SCTP None Y Services th
- None SCTP When the value Y Services th
- None RNC None Not involved Not involv
- None SCTP This paramete Y Services th
- None SCTP When the value Y Services th
- None SCTP When the value Y Services th
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
E1/T1
link(SET
E1T1LOP)
- None Loopback
optical
port(SET
OPTLOP)
None Y Services ca
1 1 LGC port When the value N (No impact on the UE in Not involv
- None RNC When the value Not involved Not involv
LGC
port(ADD
IPLOGICP
ORT)
IMA
group(RM
- None
V
IPLOGICP
ORT)
IP
Path(ADD
IPPATH)
When the value Not involved Not involv
- None LGC port None Transmission Resource M Not involv
- None IP Path When the value Y IP Path
- None LGC port None Transmission Resource M Not involv
E1T1
link(SET
E1T1)
- ALL Optical
Port(SET
COPTLN
K)
None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC When the value Not involved Not involv
- None RNC When the value Not involved Not involv
- None RNC None Not involved Not involv
- 2905 The SCTP li None Y The SCTP li
- 1 RNC None N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC This parameter i N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
Ethernet
port(PING
MAC,ACT
ETHCC,A
DD
- None ETHMEP,
ADD
ETHMA)
RNC(TRC
MAC)
None Not involved Not involv
Cell(ADD
24(ADD
CELLSEL
CELLSELR 24(ADD
RESEL)
ESEL) CELLSELRESEL)
-(ADD None(ADD
RNC(ADD
NRNCCEL NRNCCELL)
NRNCCE
L)
LL)
This paramter i N(impact on Cell Selection Not involv
FALSE FALSE RNC None N (No impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
10 When the application SCTP The value to b N (No impact on the UE in Not involv
1 1 RNC None N (No impact on the UE in Not involv
1 1 RNC None N (No impact on the UE in Not involv
- None RAB
None. N (No impact on the UE in Not involv
1.When the
value of
[PARA]BWADJ
[/PARA] in
[MML]ADD
IPLOGICPORT[
/MML] is set to
ON, this
parameter should
be set.
2.
[PARA]MINBW
[/PARA] must
be less than
[PARA]MAXB
W[/PARA].
- None LGC port N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MaxCA
PSLowLoad[/PA
RA] >
[PARA]MaxCA
PSMidLoad[/PA
RA] >
[PARA]Sharing
OutCAPSMidLo
ad[/PARA].
- 150 RNC N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MaxCA
PSLowLoad[/PA
RA] >
[PARA]MaxCA
PSMidLoad[/PA
RA] >
[PARA]Sharing
OutCAPSMidLo
ad[/PARA].
- 100 RNC N (No impact on the UE in Not involv
4 4 SAAL None N (No impact on the UE in Not involv
Cell(ADD
3(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
3 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
D15 D15 Transport c None Not involved Not involv
- 49 RNC None N (no impact on the UE in Not involv
- 3 RNC The value of t N (No impact on the UE in Not involv
- None RAB This parameter N (No impact on the UE in Not involv
48 48 Cell None N (No impact on the UE in Not involv
10 10 Transport c None N (No impact on the UE in Not involv
270 270 IP Path When the value N (no impact on the UE in Not involv
- 16 RNC None N (no impact on the UE in Not involv
64 64 Cell None N (No impact on the UE in Not involv
20 20 Cell None N (No impact on the UE in Not involv
- 3 RNC
None N (No impact on the UE in Not involv
256 256 PPP Link [PARA]MAXMFLE Y PPP link
- None MLPPP GrouWhen the value N (No impact on the UE in Not involv
1 1 NodeB None. N (No impact on the UE in Not involv
0 0 SAAL When the value N (No impact on the UE in Not involv
5 When the application SCTP The value to b N (No impact on the UE in Not involv
346 346 Cell None N (No impact on the UE in Not involv
UNI: 25
- NNI: 500 SAAL None N (No impact on the UE in Not involv
The value of
this parameter
must be set to
meet the
following
conditions:
100 x
[PARA]MaxQue
ueTimeLen[/PA
RA] >
[PARA]PollTim
erLen[/PARA].
- 5 RNC N (No impact on the UE in Not involv
64 64 PPP Link [PARA]MAXMFLE
Y PPP link
1.When the
value of
[PARA]PPPMU
X[/PARA] in
[MML]ADD
MPGRP[/MML]
is set to
ENABLE, this
parameter should
be set.
2.
[PARA]MAXM
FLEN[/PARA]
must not be less
than
[PARA]MAXSF
LEN[/PARA]*2
+8.
- None MPGRP, P N (No impact on the UE in Not involv
75 75 Cell None N (No impact on the UE in Not involv
12 12 RNC None Not involved Not involv
Cell(ADD
CELLMB
MSSA)
RNC(ADD
- None
SAMBMS
PARA,AD
D
MBMSSA
)
None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- ON RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
Cell(ADD
PTM(ADD
CELLMB
SAMBMSP
MSPARA)
ARA,ADD
RNC(SET
CELLMBM
PTM RNCMBM
SPARA)
SPARA,A
-(SET
DD
RNCMBMS
SAMBMS
PARA)
PARA)
None N (No impact on the UE in Not involv
- 1000 SAALLNK/AA
When the value Not involved Not involv
RNC(ADD
IMSISNA
MAP,AD
D
LASNAM
- None
AP,ADD
CNOPER
ATOR)
Cell(ADD
GSMCEL
L)
Ethernet
- None
port
None Not involved Not involv
- None Ethernet por None Not involved Not involv
AUTO(AD Cell(ADD
D CELLINT
CELLINTE ERRATH
RRATHOC AUTO OCOV)
OV) RNC(SET
-(SET INTERRA
INTERRAT THOCOV)
HOCOV)
This parameter N (No impact on the UE in Not involv
Ethernet
- None
port None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None Ethernet por When the value Not involved Not involv
LONG LONG MLPPP Gro None N (No impact on the UE in Not involv
- None Cell None Not involved Not involv
-7 -7 Cell None N (No impact on the UE in Not involv
FALSE FALSE Cell This paramter N (No impact on the UE in Not involv
- None LGC port When the value N (No impact on the UE in Not involv
D14 D14 Transport c None Not involved Not involv
SF8 SF8 NodeB None. N (No impact on the UE in Not involv
- 21 RNC None N (no impact on the UE in Not involv
Cell(ADD
CELLQU
ALITYME
- None AS)
RNC(SET
QUALITY
MEAS)
Valid when [PA N (no impact on the UE in Not involv
Cell(ADD
CELLQU
ALITYME
- None AS)
RNC(SET
QUALITY
MEAS)
Valid when [PAR N (no impact on the UE in Not involv
Cell(ADD
CELLQU
ALITYME
- None AS)
RNC(SET
QUALITY
MEAS)
Valid when [PAR N (no impact on the UE in Not involv
dTimerLen[/PA
RA]/2 .
- None RNC
This paramter is N (No impact on the UE in Not involv
valid only when
- None RNC
This paramter i N (No impact on the UE in Not involv
- None RNC
This paramter i N (No impact on the UE in Not involv
- None RNC
This paramter i N (No impact on the UE in Not involv
- None RNC This paramter i
dTimerLen[/PA N (No impact on the UE in Not involv
RA]/2 .
- None RNC
This paramter is N (No impact on the UE in Not involv
valid only when
- None RNC
This paramter i N (No impact on the UE in Not involv
Cell(ADD
CELLQU
ALITYME
- None AS)
RNC(SET
QUALITY
MEAS)
Valid when [PAR N (no impact on the UE in Not involv
1 1 IMA group None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MinPCP
ICHPower[/PAR
A] <=
[PARA]MaxPCP
ICHPower[/PAR
A].
313 313 Cell N (No impact on the UE in Not involv
30 30 Ethernet por When the value Not involved Not involv
30 30 Ethernet por When the value Not involved Not involv
SF4 SF4 NodeB None. N (No impact on the UE in Not involv
8 8 Transport c None Y Cell
RNC(ADD
IMSISNA
MAP,AD
D
LASNAM
- None
AP,ADD
CNOPER
ATOR)
Cell(ADD
GSMCEL
L)
MLPPP
Group,
MLPPP
Link(ADD
MPGRP)
- None
RNC(ADD
MPLNK,R
MV
MPGRP)
None N (No impact on the UE in Not involv
MPS_NEUT MPS_NEUTRAL SAAL When the value Not involved Not involv
MCPPP MCPPP MLPPP Gro None N (No impact on the UE in Not involv
- None Board None Not involved Not involv
- D12 RNC None N (no impact on the UE in Not involv
TRAFFIC_AMR: not
selected
TRAFFIC_VP: not
selected
TRAFFIC_BE: not
selected
TRAFFIC_OTHER:
not selected
- RNC None N (no impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- OFF RNC None N (No impact on the UE in Not involv
- None Cell When the value o N (The UE in idle mode maNot involv
OFF OFF Cell None N (The UE in idle mode maNot involv
- None MSP protect None Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MtchMa
xPwr[/PARA] >
[PARA]MtchRs
vPwr[/PARA] .
60 60 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MtchMa
xSf[/PARA] >
[PARA]MtchRs
vSf[/PARA] .
40 40 Cell N (No impact on the UE in Not involv
80(ADD Cell(ADD
CELLMBM CELLMB
SFACH) MSFACH)
80
-(SET RNC(SET
MBMSFAC MBMSFA
H) CH)
The value of th Not involved Not involv
50(ADD Cell(ADD
CELLMBM CELLMB
SFACH) MSFACH)
50
-(SET RNC(SET
MBMSFAC MBMSFA
H) CH)
The value of th Not involved Not involv
- D16 RNC None N (No impact on the UE in Not involv
- FALSE RNC None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MtchMa
xPwr[/PARA] >
[PARA]MtchRs
vPwr[/PARA].
20 20 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MtchMa
xSf[/PARA] >
[PARA]MtchRs
vSf[/PARA] .
16 16 Cell N (No impact on the UE in Not involv
Ethernet
port(SET
ETHPORT
-(SET
)
ETHPORT)
1500
1500(ADD
SCTP(AD
SCTPLNK)
D
SCTPLNK
)
None Y Port
PPP
Link(ADD
1000(ADD 1000(ADD PPPLNK)
PPPLNK) PPPLNK) MLPPP
-(ADD None(ADD Group,
MPGRP) MPGRP) PPP
Link(ADD
MPGRP)
When the value Y PPP link
- None Ethernet por When the value Not involved Not involv
100 100 SAAL When the value N (No impact on the UE in Not involv
- 3 RNC None N (No impact on the UE in Not involv
- 3 RNC None N (No impact on the UE in Not involv
- 3 RNC None N (No impact on the UE in Not involv
- 1 RNC None N (No impact on the UE in Not involv
- D1 RNC
None N (No impact on the UE in Not involv
- D50 RNC None N (No impact on the UE in Not involv
- D1 RNC None N (No impact on the UE in Not involv
- D1 RNC None N (No impact on the UE in Not involv
RNC(ADD
OPC,ADD
N7DPC,A
DD
M3RT,AD
D
M3LNK,A
DD
M3LKS,A
DD
M3LE,AD
D
MTP3LKS
,ADD
- None
MTP3RT)
Adjacent
Node(AD
D
ADJNOD
E)
MTP3(AD
D
MTP3LN
K)
M3UA(A
DD
M3DE)
None N (No impact on the UE in Not involv
The value of
this parameter
must be set to
meet the
following
conditions:
[PARA]NB01ma
x[/PARA] >=
[PARA]NB01mi
0 0 Transport c n[/PARA]. Y Cell
The value of
this parameter
must be set to
meet the
following
conditions:
[PARA]NB01ma
x[/PARA] >=
[PARA]NB01mi
0 0 Transport c n[/PARA]. Y Cell
- 20 RNC None N (No impact on the UE in Not involv
- 58080 The SCTP li None Y The SCTP l
- None RNC When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- 20 RNC None N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None Cell None N (No impact on the UE in Not involv
- None Cell If the Downlink N (No impact on the UE in Not involv
- None Cell PUC should not N (No impact on the UE in Not involv
- None Cell
None N (No impact on the UE in Not involv
20 20 Cell This paramter i N (No impact on the UE in Not involv
- None RNC
Cell(ADD
4(ADD
CELLMB
SAMBMSP
MSPARA)
ARA,ADD
RNC(SET
CELLMBM
4 RNCMBM
SPARA)
SPARA,A
-(SET
DD
RNCMBMS
SAMBMS
PARA)
PARA)
None N (No impact on the UE in Not involv
- ON RNC None N (No impact on the UE in Not involv
8 8 Cell This paramter i N(impact on Cell Selection Not involv
DIRECT_CODIRECT_CONNECT RNC None Y RNC
IP
Route(AD
D IPRT)
- None
RNC(ADD
IPRTBIN
D)
For AEUa/AOUa/UO
Not involved Not involv
- None RNC None Not involved Not involv
Cell(ADD
3(ADD
CELLMB
SAMBMSP
MSPARA)
ARA,ADD
RNC(SET
CELLMBM
3 RNCMBM
SPARA)
SPARA,A
-(SET
DD
RNCMBMS
SAMBMS
PARA)
PARA)
None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC
OMCH(A
DD
PPPLNK)
Ethernet
0(ADD port(SET
0(ADD
IPLOGICP ETHPORT
IPLOGICPORT,AD
ORT,ADD )
D MPGRP,ADD
MPGRP,AD MLPPP
PPPLNK)
D PPPLNK) Group,
None(SET
-(SET PPP
ETHPORT)
ETHPORT) Link(ADD
MPGRP)
LGC
port(ADD
IPLOGICP
ORT)
None Not involved Not involv
- None Port Queue [PARA]OAMFLOW N (No impact on the UE in Not involv
- None Port Queue None N (No impact on the UE in Not involv
4 4 Cell None N (No impact on the UE in Not involv
-4 -4 Cell None N (No impact on the UE in Not involv
4 4 Cell None N (No impact on the UE in Not involv
-4 -4 Cell None N (No impact on the UE in Not involv
2 2 Cell None N (No impact on the UE in Not involv
-2 -2 Cell None
this parameter N (No impact on the UE in Not involv
must satisfy the
following
relationship:
[PARA]OlcPerio
dTimerLen[/PA
RA] > 2 x 60 x
1000 x
[PARA]MinFor
UlBasicMeas[/P
ARA];
[PARA]OlcPerio
dTimerLen[/PA
RA] > 2 x 60 x
1000 x
[PARA]MinFor
DlBasicMeas[/P
- 3000 RNC ARA];
When
[PARA]ChoiceR
prtUnitForUlBas
icMeas[/PARA]
and
[PARA]ChoiceR
prtUnitForDlBas
icMeas[/PARA]
are set to
TEN_MSEC,the
value of this
parameter must
satisfy the
following
relationship:
[PARA]OlcPerio N (No impact on the UE in Not involv
- None RNC dTimerLen[/PA
None Not involved Not involv
- None RAB None. N (No impact on the UE in Not involv
- None Optical Port None Not involved Not involv
- R5_PosData_SWITC RNC None N (no impact on the UE in Not involv
- None Correspondi When the value Not involved Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
Step_by_Ste Step_by_Step RNC None N (No impact on the UE in Not involv
ACTIVE ACTIVE Cell Valid when [PA N (no impact on the UE in Not involv
- UE_ASSISTED RNC None N (no impact on the UE in Not involv
NOT_FORBINOT_FORBIDDEN RNC This paramete N (No impact on the UE in Not involv
LOCAL LOCAL AAL2 Path None N (No impact on the UE in Not involv
YES YES Services ca None N (no impact on the UE in Not involv
DISABLED DISABLED IP Path None N (no impact on the UE in Not involv
- None AAL2 Path When the value N (No impact on the UE in Services c
AAL2
Path(ADD
AAL2PAT
H)
- None
AAL2PAT
H(ACT
VCLCC)
When the value Not involved Not involv
IP
Path(ADD
IPPATHBI
ND,ADD
- None
IPPATH)
IP
path(ACT
IPPM)
None Not involved Not involv
- QOS IP Path When the value Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
-20 -20 Transport c None N (Impact on page messageNot involv
2. To modify the
PCPICH power,
330 330 Cell the intra-
frequency load N (Impact on pilot messag Not involv
2 2 Cell balance
None N (No impact on the UE in Not involv
1.When the
value of
[PARA]ST[/PA
RA] in
[MML]ADD
ATMTRF[/MM
L] is set to CBR
or RTVBR or
NRTVBR and
[PARA]UT[/PA
RA] is selected,
this parameter
should be set.
2.
[PARA]PCR[/P
ARA] must be
larger than
[PARA]SCR[/P
ARA].
- None SAALLNK/AA Not involved Not involv
- PC_AMR_MODE_IND
RNC None N (no impact on the UE in Not involv
5 5 RNC None N (No impact on the UE in Not involv
1000 1000 Ethernet por None Not involved Not involv
- None Cell
None N (No impact on the UE in Not involv
- None MLPPP Gro None N (No impact on the UE in Not involv
- None Ethernet por None Not involved Not involv
- None SCTP None Y Services th
- None SCTP None Y Services th
- None IPOA When the value N (No impact on the UE in Services c
- None RNC None Not involved Not involv
- None Global When the value Not involved Not involv
- None IP Path [PARA]IPADDR[Not involved Not involv
Cell(ADD
1(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) 1
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
This parameter N (No impact on the UE in Not involv
4(ADD Cell(ADD
CELLINTE CELLINT
RFREQHO ERFREQH
NCOV) ONCOV)
4
-(SET RNC(SET
INTERFRE INTERFR
QHONCOV EQHONC
) OV)
None N (No impact on the UE in Not involv
1(ADD Cell(ADD
CELLINTE CELLINT
RRATHOC ERRATH
OV) 1 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV) THOCOV)
This parameter N (No impact on the UE in Not involv
Cell(ADD
4(ADD
CELLINT
CELLINTE
ERRATH
RRATHON
ONCOV)
COV) 4
RNC(SET
-(SET
INTERRA
INTERRAT
THONCO
HONCOV)
V)
None N (No impact on the UE in Not involv
Cell(ADD
D16(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
D16 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
D16(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
D16 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
Cell(ADD
D64(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
D64 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
None N (No impact on the UE in Not involv
- 150 RNC
None N (No impact on the UE in Not involv
- None Physical ch This parameter N (Impact on random acces Not involv
PPP
Link(ADD
PPPLNK)
Enable Enable MLPPP
Link, PPP
Link(ADD
MPLNK)
None Y PPP link
- None IP path When the value Not involved Not involv
- None Board 1.The phb of the Not involved Not involv
DD
-(ADD SSCH,AD
FACH,ADD D
PICH,ADD PSCH,AD
PCH,ADD D
SCCPCHTF PRACHB
C,ADD ASIC,AD
SCCPCHB D
None(ADD
ASIC) PRACHTF
FACH,ADD
3(ADD C,ADD
PRACHACTOASC
PCCPCH) FACH,AD
MAP,ADD
6(ADD D
PCH,ADD
AICH) PICH,AD
SCCPCHTFC,ADD
4(ADD D
PCCPCH,ADD
PRACHBA PRACHA
SCCPCHBASIC)
SIC,ADD SC,ADD
6(ADD AICH)
PRACHTF PRACHSL
4(ADD
C,ADD OTFORM
PRACHBASIC,ADD
PRACHAS AT,ADD
PRACHTFC,ADD
C,ADD PCH,ADD
PRACHASC,ADD
PRACHSL SCCPCHT
PRACHSLOTFORM
OTFORMA FC,ADD
AT,ADD RACH)
T,ADD PCPICH,A
2(ADD PCPICH)
PRACHAC DD
8(ADD PICH)
TOASCMA RACH,AD
0(ADD PSCH)
P,ADD D
1(ADD SSCH)
RACH) AICH,AD
2(ADD D
PCPICH) PCCPCH,
0(ADD ADD
PSCH) SCCPCHB
1(ADD ASIC)
SSCH) Cell(ADD
PRACHA None Not involved Not involv
- None Cell None Not involved Not involv
10 10 Physical ch None Not involved Not involv
V36 V36 Physical ch None Not involved Not involv
-7 -7 Cell None N (Impact on page messageNot involv
- None Ethernet por None Not involved Not involv
10 10 RNC None Y Port
128 128 RNC None Y Port
128 128 Ethernet por None Not involved Not involv
56 56 Ethernet por None Not involved Not involv
128 128 Ethernet por None Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
- None RNC [PARA]PlmnVal
TagMax[/PARA
]>
[PARA]PlmnVal
TagMin[/PARA]
.
Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
- None RNC [PARA]PlmnVal
TagMax[/PARA
]>
[PARA]PlmnVal
TagMin[/PARA]
.
Not involved Not involv
10 10 LGC port When the value N (No impact on the UE in Not involv
30 30 LGC port When the value N (No impact on the UE in Not involv
1 1 IP path
optical If the Ip pathin
PE[/PARA] N (No impact on the UE in Not involv
- None port(SET [MML]STR Not involved Not involv
- None OPTLOP)
RNC IPCHK[/MML]
None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None RNC None Y Port
- None Ethernet por When the value Not involved Not involv
- None SRB None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
The value of
this parameter
must be set to
meet the
following
conditions:
100 x
[PARA]MaxQue
ueTimeLen[/PA
RA] >
[PARA]PollTim
erLen[/PARA].
- 50 RNC N (No impact on the UE in Not involv
UNI: 750
- NNI: 100 SAAL None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
- None Ethernet por None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- In signaling transmis Physical ch None Not involved Not involv
2 2 Physical ch None N (Impact on random acces Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None LGC port None Not involved Not involv
PPP
Link(ADD
PPPLNK)
(RST
MPLNK,R
ST
PPPLNK)
MLPPP
- None
Link(ADD
MPLNK)
RNC(RM
V
MPLNK,R
MV
PPPLNK)
The parameter [ Not involved Not involv
PPP
Link(ADD
PPPLNK)
MLPPP
Enable Enable
Group,
PPP
Link(ADD
MPGRP)
None Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
4 4 Physical ch None Not involved Not involv
Cell(ADD
D500(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) D500
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
This parameter N (No impact on the UE in Not involv
D500 D500 Cell None N (No impact on the UE in Not involv
20 20 Physical ch None N (Impact on random acces Not involv
- SIGNATURE0, SIGNPhysical ch None N (Impact on random acces Not involv
- OFF RNC None N (No impact on the UE in Not involv
- ON RNC None N (No impact on the UE in Not involv
- None IP Route None Not involved Not involv
MTP3(AD
D
MTP3LN
0 0 K)
Priority
for the
link(ADD
M3LNK)
None N (No impact on the UE in Not involv
RNC(ADD
MTP3RT)
The route
to the
0 0 specific
M3DE
decides the
sequence.
(ADD
M3RT)
None N (No impact on the UE in Not involv
HIGH HIGH Cell None Not involved Not involv
- ARP RNC None N (No impact on the UE in Not involv
1 1 RNC None. N (No impact on the UE in Not involv
1 1 RNC None. N (No impact on the UE in Not involv
1 1 RNC None. N (No impact on the UE in Not involv
1 1 RNC None. N (No impact on the UE in Not involv
1 1 RNC None. N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
ITUT ITUT RNC None Not involved Not involv
the same time.
- 20 RNC N (No impact on the UE in Not involv
2. For
the thetime.
same
- 20 RNC N (No impact on the UE in Not involv
2. For thetime.
the same
- 20 RNC N (No impact on the UE in Not involv
2.
theFor thetime.
same
- 20 RNC N (No impact on the UE in Not involv
2. For the
1. For the
detection timers
that do not need
to configure
streaming
services, the
related T1 and
T2 must be 0 at
the same time.
2. For the
detection timers
that need to
configure
streaming
services, the
related T1 and
T2 must not be 0
at the same time.
- None Cell
None Y Cell
30 30 RNC None N (No impact on the UE in Not involv
100 100 RNC None N (No impact on the UE in Not involv
This parameter
is valid when
[PARA]NcovHo
On2GldInd[/PA
Cell(ADD
60(ADD RA] in
CELLINT
CELLINTE [MML]SET
ERRATH
RRATHON INTERRATHO
ONCOV)
COV) 60 NCOV[/MML]
RNC(SET
-(SET is set to ON.
INTERRA
INTERRAT This parameter
THONCO
HONCOV) is valid when
V)
[PARA]NcovHo
On2GldInd[/PA
RA] is set to
ON.
N (No impact on the UE in Not involv
the same time.
- 20 RNC N (No impact on the UE in Not involv
2. For
the thetime.
same
- 20 RNC N (No impact on the UE in Not involv
2. For thetime.
the same
- 20 RNC N (No impact on the UE in Not involv
2.
theFor thetime.
same
- 20 RNC N (No impact on the UE in Not involv
2. For the
1. For the
detection timers
that do not need
to configure
streaming
services, the
related T1 and
T2 must be 0 at
the same time.
2. For the
detection timers
that need to
configure
streaming
services, the
related T1 and
T2 must not be 0
at the same time.
- 32 RNC
None
ARA]; N (No impact on the UE in Not involv
When
- 1800 RNC
[PARA]ChoiceR N (No impact on the UE in Not involv
- 10 RNC prtUnitForDlBas
None N (No impact on the UE in Not involv
- ALGORITHM1 RNC None N (No impact on the UE in Not involv
- None Port Queue From [PARA]Q0 N (No impact on the UE in Not involv
- None Port Queue From [PARA]Q0 N (No impact on the UE in Not involv
- None Port Queue From [PARA]Q0 N (No impact on the UE in Not involv
- None Port Queue From [PARA]Q0 N (No impact on the UE in Not involv
- None Port Queue From [PARA]Q0 N (No impact on the UE in Not involv
CS2 CS2 Adjacent N When the value N (No impact on the UE in Not involv
This paramter is
Cell(ADD
valid only when
GSMCEL
[PARA]UseOfH
L,ADD
cs[/PARA] is set
CELLHCS
to USED.
20 20 )
This paramter is
valid only when
RNC(ADD
[PARA]UseOfH
NRNCCE
cs[/PARA] is set
LL)
to TRUE.
N (No impact on the UE in Not involv
255 255 Cell None N(impact on Cell Selection Not involv
255 255 Cell None N(impact on Cell Selection Not involv
255 255 Cell None N(impact on Cell Selection Not involv
255 255 Cell None N(impact on Cell Selection Not involv
0 0 Cell None N(For the UE in idle mode, Not involv
Cell(ADD
-18(ADD
CELLSEL
CELLSELR -18(ADD
RESEL)
ESEL) CELLSELRESEL)
-(ADD None(ADD
RNC(ADD
NRNCCEL NRNCCELL)
NRNCCE
L)
LL)
This paramter i N(impact on Cell Selection Not involv
FALSE FALSE RNC None N (For the UE in idle mode Not involv
-50 -50 Cell None N(For the UE in idle mode, Not involv
Cell(ADD
-58(ADD
CELLSEL
CELLSELR -58(ADD
RESEL)
ESEL) CELLSELRESEL)
-(ADD None(ADD
RNC(ADD
NRNCCEL NRNCCELL)
NRNCCE
L)
LL)
This paramter i N(impact on Cell Selection Not involv
Cell(ADD
CELLSEL
RESEL)
FALSE FALSE
RNC(ADD
NRNCCE
LL)
This paramter i N(impact on Cell Selection Not involv
FALSE FALSE RNC None N (For the UE in idle mode Not involv
CPICH_ECNCPICH_ECNO Cell None N(impact on Cell Selection Not involv
- OFF RNC None N (No impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
RAB(ADD
TYPRAB
OLPC)
(ADD
TYPRAB
BASIC,A
DD
TYPRAB
HSPA,AD
- None D
TYPRAB
RLC,ADD
TYPRAB
DCCCMC
)
RNC(ADD
TYPRAB
QUALITY
MEAS)
RNC(ADD
NRNCCE
LL,ADD
QUICKCE
LLSETUP,
- None ADD
CELLSET
UP,ADD
RAC)
Cell(ADD
GSMCEL
L)
- None RNC
None Not involved Not involv
- None RNC None Not involved Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
96 96 LGC port When the value N (No impact on the UE in Not involv
- 6 RNC The value of th N (No impact on the UE in Not involv
130 130 Cell None N (No impact on the UE in Not involv
1.When the
value of
[PARA]BWADJ
[/PARA] in
[MML]ADD
IPLOGICPORT[
/MML] is set to
ON, this
parameter should
be set.
2.
[PARA]RECOV
ERTHD[/PARA]
must be larger
than
[PARA]RPTTH
D[/PARA].
30 30 LGC port N (No impact on the UE in Not involv
- None Board None Not involved Not involv
This parameter
is valid when
-(ADD
RNC(SET [PARA]RedirBa
CELLREDI
REDIREC ndInd[/PARA] is
RECTION,
DependOnNCell(AD TION,SET not set to
SET
D CELLDRD,SET DRD) BandIndNotUse
REDIRECT
DRD) Cell(ADD d.
ION,SET
None(ADD CELLRED 1. This
DRD)
CELLREDIRECTIO IRECTIO parameter is
N,SET N,ADD valid when
DependOnN
REDIRECTION) CELLDR [PARA]RedirSw
Cell(ADD
D) itch[/PARA] is
CELLDRD)
set to
ONLY_TO_INT N (No impact on the UE in Not involv
[PARA]RedirSw
itch[/PARA] is
AMR:100;
RNC(SET set to
Other:0(SET
REDIREC ONLY_TO_INT
REDIRECTION)
TION) ER_FREQUEN
- Cell(ADD CY or
AMR:100;Other:0(A
CELLRED ONLY_TO_INT
DD
IRECTIO ER_RAT.
CELLREDIRECTIO
N) 2. If the value of
N)
this parameter is N (No impact on the UE in Not involv
set in both theis
itch[/PARA]
RNC(SET set to
REDIREC ONLY_TO_INT
TION) ER_FREQUEN
- 0 Cell(ADD CY or
CELLRED ONLY_TO_INT
IRECTIO ER_RAT.
N) 2. If the value of
this parameter is N (No impact on the UE in Not involv
RNC(SET
REDIREC
TION)
- None Cell(ADD
CELLRED
IRECTIO
N)
None N (No impact on the UE in Not involv
If this parameter
is set through
both the
[MML]ADD
CELLDRD[/MM
L] and
[MML]SET
DRD[/MML]
commands, the
parameter set
through the
[MML]ADD
RNC(SET CELLDRD[/MM
REDIREC L] command
TION,SET takes precedence
DRD) over that set
Cell(ADD through the
- None
CELLRED [MML]SET
IRECTIO DRD[/MML]
N,ADD command.
CELLDR The value range
D) of this parameter
depends on the
setting of the
[PARA]ReDirBa
ndInd[/PARA]
parameter, as
shown below:
Band1
Common
frequencies:
[10562-10838]
Special
frequencies: N (No impact on the UE in Not involv
[MML]SET
DRD[/MML]
commands, the
parameter set
through the
[MML]ADD
CELLDRD[/MM
L] command
takes precedence
over that set
through the
[MML]SET
RNC(SET DRD[/MML]
REDIREC command. This
TION,SET parameter is
DRD) required only
Cell(ADD when the
- None
CELLRED [PARA]ReDirU
IRECTIO ARFCNUplinkIn
N,ADD d[/PARA]
CELLDR parameter is set
D) to TRUE.
The value range
of this parameter
depends on the
setting of the
[PARA]ReDirBa
ndInd[/PARA]
parameter, as
shown below:
Band1:
Common
frequencies:
[9612-9888] N (No impact on the UE in Not involv
command.
This parameter
RNC(SET
is valid when
REDIREC
[PARA]RedirBa
TION,SET
ndInd[/PARA] is
DRD)
not set to
Cell(ADD
- None BandIndNotUse
CELLRED
d.
IRECTIO
1. This
N,ADD
parameter is
CELLDR
valid when
D)
[PARA]RedirBa
N (No impact on the UE in Not involv
ndInd[/PARA]isis
CLK[/MML]
- None board Y RNC
set to
- None board None Y RNC
- None board None Y RNC
- ON RNC None N (No impact on the UE in Not involv
- REHOSTRIGHNOW RNC None N (No impact on the UE in Not involv
- 3000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 10000 RNC None N (No impact on the UE in Not involv
- 15000 RNC None N (No impact on the UE in Not involv
- 20000 RNC None N (No impact on the UE in Not involv
- 3000 RNC None N (No impact on the UE in Not involv
- 45000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 10000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
SAALLN
K/AAL3P
ATH/IPO
APVC/VP
- None
CLCX
using this
ATM
traffic
record
index(AD
D
ATMTRF)
None Not involved Not involv
- None RNC
None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 300 RNC None N (No impact on the UE in Not involv
Cell(ADD
D4000(AD
CELLINT
D
RAFREQ
CELLINTR
D4000 HO)
AFREQHO)
RNC(SET
-(SET
INTRAFR
INTRAFRE
EQHO)
QHO)
None N (No impact on the UE in Not involv
Cell(ADD
D4000(AD
CELLINT
D
RAFREQ
CELLINTR
D4000 HO)
AFREQHO)
RNC(SET
-(SET
INTRAFR
INTRAFRE
EQHO)
QHO)
None N (No impact on the UE in Not involv
Cell(ADD
D1000(AD
CELLINT
D
RAFREQ
CELLINTR
D1000 HO)
AFREQHO)
RNC(SET
-(SET
INTRAFR
INTRAFRE
EQHO)
QHO)
None N (No impact on the UE in Not involv
- None RAB None. N (No impact on the UE in Not involv
- RESERVED_SWITCH_
RNC None N (no impact on the UE in Not involv
- RESERVED_SWITCH_
RNC None N (no impact on the UE in Not involv
- 0 RNC None N (no impact on the UE in Not involv
- 4294967295 RNC None N (no impact on the UE in Not involv
- 0 RNC None N (no impact on the UE in Not involv
- 255 RNC None N (no impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
PPP
Link(ADD
PPPLNK)
3 3 MLPPP
Link, PPP
Link(ADD
MPLNK)
None Not involved Not involv
1 1 RAB This parameter N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RAB None. N (No impact on the UE in Not involv
Transport
- None
channel
None Not involved Not involv
- None Cell The value of th N (No impact on the UE in Not involv
- None Cell The value of th N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
RNC(ADD
GSMNCE
LL,ADD
INTERFR
EQNCELL
,ADD
INTRAFR
- None
EQNCELL
,ADD
CELLINT
RAFREQ
HO)
Cell(ADD
SMLCCE
LL)
RNC(ADD
- None GPS)
(RST
RNC) None Not involved Not involv
- None Subsystem None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
1.When the
value of
[PARA]BWADJ
[/PARA] in
[MML]ADD
IPLOGICPORT[
/MML] is set to
ON, this
parameter should
be set.
2.
[PARA]RECOV
ERTHD[/PARA]
must be larger
than
[PARA]RPTTH
D[/PARA].
20 20 LGC port N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 200 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
- 4 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 350 RNC None N (No impact on the UE in Not involv
- 1000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- None AAL2 Path When the value Y AAL2 Path
- None AAL2 Path When the value Y AAL2 Path
- None IP Path When the value Y IP Path
LGC
port(ADD
IPLOGICP
ORT)
- None Transmissi
on
resource
group(AD
D
RSCGRP)
When [PARA]ISFNot involved Not involv
- None LGC port None Transmission Resource M Not involv
SHARE SHARE NodeB None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
UNI: 15000
- NNI: 1500 SAAL None N (No impact on the UE in Not involv
NodeB(A
DD
- None
NODEBA
LGOPAR
A)
RNC(SET
CACALG
OSWITC
H)
None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
0 0 RNC None N (No impact on the UE in Not involv
0 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
Cell(ADD
CELLALG
OSWITC
0(ADD
0(ADD H)
NODEBAL
NODEBALGOPAR
GOPARA,A
A,ADD NodeB(A
DD
CELLALGOSWITC DD
CELLALG
H) NODEBA
OSWITCH)
None(SET LGOPAR
-(SET
CACALGOSWITCH A)
CACALGO
) RNC(SET
SWITCH)
CACALG
OSWITC
H)
None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
Cell(ADD
CELLALG
OSWITC
0(ADD
0(ADD H)
NODEBAL
NODEBALGOPAR
GOPARA,A
A,ADD NodeB(A
DD
CELLALGOSWITC DD
CELLALG
H) NODEBA
OSWITCH)
None(SET LGOPAR
-(SET
CACALGOSWITCH A)
CACALGO
) RNC(SET
SWITCH)
CACALG
OSWITC
H)
None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
- None Port None Y Port
The following
relationship must
be satisfied:
[PARA]RtDH2F
TvmThd[/PARA
]<
[PARA]RtEFach
2DHTvmThd[/P
ARA].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]RtDH2F
TvmThd[/PARA
]<
[PARA]RtF2Cpc
TvmThd[/PARA
].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]RtDH2F
TvmThd[/PARA
]<
[PARA]RtF2DH
TvmThd[/PARA
].
- D1024 RNC N (no impact on the UE in Not involv
- D0 RNC None N (no impact on the UE in Not involv
12 12 SCTP None N (No impact on the UE in Not involv
25 25 SCTP None N (No impact on the UE in Not involv
1000 1000 SCTP The value to be N (No impact on the UE in Not involv
3000 3000 SCTP The value to be N (No impact on the UE in Not involv
1000 1000 SCTP The value to b N (No impact on the UE in Not involv
- None Services ca None Not involved Not involv
5 5 LGC port When the value N (No impact on the UE in Not involv
5 5 LGC port When the value N (No impact on the UE in Not involv
- None LGC port None Transmission Resource M Not involv
- None IP Path None N (No impact on the UE in Not involv
- None Transmissio[PARA]CARRY
When [PARA]GRP N (No impact on the UE in Not involv
T[/PARA] in
[MML]ADD
AAL2PATH[/M
ML] is set to
SAAL(AD UNI, IMA,
D FRAATM,
SAALLN NCOPT, or
K) ATM logic port,
AAL2 this parameter is
Path(ADD valid.
AAL2PAT 1.When the
- None
H) value of
[PARA]CARRY
RNC(ADD T[/PARA] in
VPCLCX) [MML]ADD
IPoA IPOAPVC[/MM
PVC(ADD L] is set to UNI,
IPOAPVC IMA, FRAATM,
) NCOPT, or
ATMLGCPORT
, this parameter
is required. Y Not involv
2.When the
The value of the
parameter must
satisfy the
function below:
[PARA]RxTxtoT
rig6F[/PARA] -
[PARA]RxTxtoT
rig6G[/PARA]
>= 256.
- 1172 RNC N (No impact on the UE in Not involv
The value of
this parameter is
dependent on the
value of
[PARA]SAC[/P
ARA] in
- None RNC
[MML]ADD
SAC[/MML];
This service area
is not configured
as a classified
zone.
Not involved Not involv
FALSE FALSE NodeB None N (No impact on the UE in Not involv
50 50 Physical ch None Not involved Not involv
- None Cell None N (No impact on the UE in Not involv
1.When the
value of
[PARA]ST[/PA
RA] in
[MML]ADD
ATMTRF[/MM
L] is set to
RTVBR or
NRTVBR and
[PARA]UT[/PA
RA] is selected,
this parameter
should be set.
2.
[PARA]SCR[/P
ARA] must be
smaller than
[PARA]PCR[/P
ARA].
- None SAALLNK/AA Not involved Not involv
- None Physical ch None Not involved Not involv
AOUa, the value
E1T1
of
link(SET
[PARA]SCRAM
E1T1)
BLESW[/PARA]
can be set.
- None Correspon
When the value
ding
of
optical
[PARA]BT[/PA
port(SET
RA] in
OPT) Not involved Not involv
[MML]SET
The parameter
[PARA]SCTPL
NKN[/PARA] in
SCTP(AD
[MML]ADD
D
SCTPLNK[/MM
NCP,ADD
L]
CCP,ADD
- None When
SCTPLNK
[PARA]CARRY
)
LNKT[/PARA]
is SCTP or
RNC(ADD
SAAL-SCTP,
M3LNK)
this parameter is
valid.
Not involved Not involv
- None RNC When the value Y RNC
- DISABLE Port None Not involved Not involv
- None Port None Not involved Not involv
- None NodeB None N (no impact on the UE in Not involv
ALL ALL RNC None Not involved Not involv
MBMS servicMBMS service Cell None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None PPP Link None Not involved Not involv
Cell(ADD
CELLMB
MSFACH,
ADD
CELLMB
MSSCCP
CH)
- None
RNC(SET
MTCH,SE
T
MBMSFA
CH,SET
MBMSSC
CPCH)
None Not involved Not involv
RNC(SET
-(SET
DRD)
DRD)
OFF Cell(ADD
OFF(ADD
CELLDR
CELLDRD)
D) If this parame N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
Cell(ADD
CELLMB
MSFACH,
ADD
CELLMB
MSSCCP
CH)
- None
RNC(SET
MTCH,SE
T
MBMSFA
CH,SET
MBMSSC
CPCH)
None Not involved Not involv
- None Adjacent N When the value Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]MaxCA
PSLowLoad[/PA
RA] >
[PARA]MaxCA
PSMidLoad[/PA
RA] >
[PARA]Sharing
OutCAPSMidLo
ad[/PARA].
- 10 RNC N (No impact on the UE in Not involv
- DEDICATED NodeB None N (No impact on the UE in Not involv
0 0 Cell This parameter N (No impact on the UE in Not involv
- HO_TO_GSM_SHOURAB This parameter N (No impact on the UE in Not involv
- 3 RNC None N (No impact on the UE in Not involv
- 60 RNC None N (No impact on the UE in Not involv
Cell(ADD
-24(ADD CELLINT
-24(SET
CELLINTR RAFREQ
INTRAFREQHO,A
AFREQHO) HO)
DD
-(SET RNC(SET
CELLINTRAFREQ
SMLC,SET SMLC,SE
HO)
INTRAFRE T
-20(SET SMLC)
QHO) INTRAFR
EQHO)
The parameter
RNC(ADD
[PARA]SIGLKS
M3LNK,A
X[/PARA] in
DD
[MML]ADD
M3LKS,A
MTP3LKS[/MM
DD
L]
M3RT,AD
The
D
[PARA]SIGLKS
- None MTP3RT,
X[/PARA] field
ADD
in [MML]ADD
MTP3LKS
M3LKS[/MML]
)
The parameter
[PARA]SIGLKS
MTP3(AD
X[/PARA] in
D
[MML]ADD
MTP3LN
M3LKS[/MML]
K)
Ethernet
port(PING
MAC)
- None
RNC(TRC
MAC)
None Not involved Not involv
- None RNC None Y Port
- None Ethernet por None Not involved Not involv
- None RNC None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None Ethernet por None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC Only valid to th Not involved Not involv
- None Ethernet por Only valid to th Not involved Not involv
- None NodeB None Not involved Not involv
- None LGC port None Not involved Not involv
- None IMA group None Not involved Not involv
- None RNC none Not involved Not involv
SWP
the value range
BRD,ADD
of
M3LNK)
[PARA]SN[/PA
RA] is 12 to 13.
SCTP(AD
When the value
D
of
SCTPLNK
[PARA]BT[/PA
)
RA] in
(ADD
[MML]LOD
PPPLNK,
PATCH[/MML]
RST
is set to DPUb,
PPPLNK,
the value range
RST
of
MPLNK,S
[PARA]SN[/PA
TR
RA] is 8 to 19.
IMATST,
When the value
CLR
of
- None BRD)
[PARA]BT[/PA
VCL(LOP
RA] in
VCL)
[MML]LOD
E1/T1
PATCH[/MML]
link(SET
is set to SPUa,
E1T1LOP)
the value range
Cell(LOP
of
E1T1)
[PARA]SN[/PA
Ethernet
RA] is 0 to 5 and
port(ADD
8 to 11. When
ETHIP,SE
the value of
T
[PARA]BT[/PA
ETHPORT
RA] in
,ACT
[MML]LOD
ETHPORT
PATCH[/MML]
,ADD
is set to
IPRT,PIN
PEUa,AEUa,FG Not involved Not involv
- None G IP)
Board None Not involved Not involv
- None MTP3 None Not involved Not involv
Subsystem
(ADD
CBSADD
R)
Sub
System(SE
T
- None NCELLDE
TECTSWI
TCH)
RNC(ADD
IURCOM
MSCCP)
(ADD
NODEB)
- None RNC
None Not involved Not involv
- None RNC
SNAC needs to Not involved Not involv
RNC(ADD
SPG)
Cell(ADD
- None QUICKCE
LLSETUP,
ADD
CELLSET
UP)
None. N (No impact on the UE in Not involv
- None RNC
This parameter, N (No impact on the UE in Not involv
- None Ethernet por None Not involved Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]SpucHea
vy[/PARA] >=
[PARA]SpucLig
ht[/PARA];
100 >=
[PARA]SpucHea
vy[/PARA] +
[PARA]SpucHys
t[/PARA].
70 70 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]SpucLig
ht[/PARA] >=
[PARA]SpucHys
t[/PARA];
100 >=
[PARA]SpucHea
vy[/PARA] +
[PARA]SpucHys
t[/PARA].
5 5 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]SpucHea
vy[/PARA] >=
[PARA]SpucLig
ht[/PARA];
[PARA]SpucLig
ht[/PARA] >=
[PARA]SpucHys
t[/PARA].
45 45 Cell N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
- DCH RNC None. N (No impact on the UE in Not involv
- FALSE RNC None. N (No impact on the UE in Not involv
15 15 RNC None N (No impact on the UE in Not involv
32 32 Cell This parameter N (No impact on the UE in Not involv
512 512
IP or Hybird IP, the Cell This parameter N (No impact on the UE in Not involv
- parameter is EF. RNC When the value N (No impact on the UE in Not involv
100 When the interface
100 RNC None N (No impact on the UE in Not involv
- parameter is EF; RNC When the value N (No impact on the UE in Not involv
transimssion type is
0 0 RNC None N (No impact on the UE in Not involv
15 15 RNC None N (No impact on the UE in Not involv
- None E1/T1 None N (No impact on the UE in Not involv
RNC(ADD
CLKSRC)
- None
ethprot(R
MV
CLKSRC)
None Not involved Not involv
- None RNC When the value N (No impact on the UE in Not involv
The parameter
must not be the
same as any IP
address that has
been configured
in the RNC.
The parameter
must not be the
same as the
internal IP
address of the
BAM.
- None RNC Not involved Not involv
Ethernet
port(PING
MAC)
- None
RNC(TRC
MAC)
None Not involved Not involv
- None RNC When 2MBPS exist
Not involved Not involv
- None E1/T1 None N (No impact on the UE in Not involv
60 60 SAAL When the value N (No impact on the UE in Not involv
- None RNC When the value N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
- None RNC None Not involved Not involv
Subsystem
(ADD
CBSADD
R)
Sub
System(SE
- None T
NCELLDE
TECTSWI
TCH)
RNC(ADD
IURCOM
MSCCP)
- None RNC
None Not involved Not involv
- None RNC
None Not involved Not involv
- None RNC None N (No impact on the UE in Not involv
- YES RNC Valid when [PAR N (no impact on the UE in Not involv
- NRT RNC None N (No impact on the UE in Not involv
- 400 RNC None N (No impact on the UE in Not involv
- 60 RNC None N (No impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 30 RNC None N (No impact on the UE in Not involv
- SRNSR_DSCR_IUR_RNC None N (no impact on the UE in Not involv
- 60 RNC None N (No impact on the UE in Not involv
- None UE SRNTI needs to Not involved Not involv
- None board None Y RNC
-50 -50 Physical ch None N (Impact on network sear Not involv
- 60 board [PARA]SSCPUA Not involved Not involv
- 70 board [PARA]SSCPUM Not involved Not involv
1.When the
value of
[PARA]BT[/PA
RA] in
[MML]SET
CPUTHD[/MML
] is set to DPUb,
the value of
[PARA]SSDSPA
VEUSAGEALM
THD[/PARA]
should be set.
2.
[PARA]SSDSP
MAXUSAGEAL
MTHD[/PARA]
must be bigger
than
[PARA]SSDSPA
VEUSAGEALM
THD[/PARA].
- None RNC
None Not involved Not involv
- 03&00&00 RNC When the value Y RNC
- rate unit should
It is recommended tha SAALLNK/AA Not involved Not involv
be set; when the
- 500 RNC Restriction: [ N (no impact on the UE in Not involv
ACTIVE ACTIVE Cell None N (no impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- None Cell This paramter i N (No impact on the UE in Not involv
- 20000 RNC None N (No impact on the UE in Not involv
20 20 SCCP None N (No impact on the UE in Not involv
67 67 SAAL None N (No impact on the UE in Not involv
OFF OFF RNC When the value Y RNC
- None RNC None Not involved Not involv
- D16 RNC None N (No impact on the UE in Not involv
32 32 Cell This parameter N (No impact on the UE in Not involv
- D384 RNC None N (No impact on the UE in Not involv
512 512 Cell This parameter N (No impact on the UE in Not involv
- D16 RNC None N (No impact on the UE in Not involv
FALSE(AD
D
CELLMBM
SSCCPCH,
ADD
Physical
PICH,ADD FALSE
channel
AICH,ADD
SCCPCHB
ASIC)
-(SET
MBMSSCC
PCH)
None N (No impact on the UE in Not involv
Cell(ADD
CELLSET
UP)
STTD_not_ STTD_not_Supporte
Supported d
RNC(ADD
NRNCCE
LL)
This paramter is Y Cell
RAB(ADD
TYPRAB
- None OLPC)
(ADD
TYPRAB
RLC)
None. N (No impact on the UE in Not involv
127 127 IP Path When the value N (no impact on the UE in Not involv
- None RNC None Not involved Not involv
FALSE FALSE Cell None Not involved Not involv
FALSE FALSE NodeB None. N (No impact on the UE in Not involv
FALSE FALSE RNC None N (No impact on the UE in Not involv
- None RNC
None Not involved Not involv
- OFF RNC When [PARA]CND
N (No impact on the UE in Not involv
YES YES SCTP None N (No impact on the UE in Not involv
10 10 SCTP None N (No impact on the UE in Not involv
OFF OFF RNC None Not involved Not involv
0 0 RNC None Not involved Not involv
OFF OFF RNC None Not involved Not involv
OFF OFF RNC None Not involved Not involv
OFF OFF RNC None Not involved Not involv
OFF OFF RNC None Not involved Not involv
OFF OFF RNC None Not involved Not involv
0 0 RNC None Not involved Not involv
0 0 RNC None Not involved Not involv
0 0 RNC None Not involved Not involv
- FIRST RNC When the value Y RNC
- 60 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 60 RNC None N (No impact on the UE in Not involv
- 10 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 100 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- 180 RNC None N (No impact on the UE in Not involv
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- D2000 RNC None N (No impact on the UE in Not involv
- D2000 RNC None N (No impact on the UE in Not involv
- D2000 RNC None N (No impact on the UE in Not involv
- D30 RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- D40 RNC None N (No impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 6 RNC
None N (No impact on the UE in Not involv
- 3 RNC None N (No impact on the UE in Not involv
- D0 RNC T314 should be s N (No impact on the UE in Not involv
- D0 RNC T315 should be s N (No impact on the UE in Not involv
- D30 RNC None N (No impact on the UE in Not involv
10 10 RNC T3212 needs to N (Changing the time for t Not involv
- D600 RNC None N (No impact on the UE in Not involv
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- None MTP3B None N (No impact on the UE in RNC
- 10 RNC None N (no impact on the UE in Not involv
Cell(ADD
-12(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) -12
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
Configured to 1
when TFsNumber is
1;Configured to 0
when TFsNumber is
2 or 3(ADD Transport
-
FACHDYNTFS) channel
None(ADD
PCHDYNTFS)
1(ADD
RACHDYNTFS)
None Not involved Not involv
1(ADD
PCHDYNT
1(ADD
FS,ADD
PCHDYNTFS,ADD
FACHDYN Transport
FACHDYNTFS)
TFS) channel
2(ADD
2(ADD
RACHDYNTFS)
RACHDYN
TFS)
This paramter is Not involved Not involv
2 2 Transport c This paramter i Not involved Not involv
1.This
parameter is
listed when the
value of
[PARA]TbNum[
/PARA] is D1,
D2, D3, or D4.
2.
[PARA]TbSizeI
ndex1[/PARA] <
[PARA]TbSizeI
ndex2[/PARA] <
[PARA]TbSizeI
ndex3[/PARA] <
[PARA]TbSizeI
ndex4[/PARA]
- None RNC N (No impact on the UE in Not involv
1.This
parameter is
listed when the
value of
[PARA]TbNum[
/PARA] is D2,
D3, or D4.
2.
[PARA]TbSizeI
ndex1[/PARA] <
[PARA]TbSizeI
ndex2[/PARA] <
[PARA]TbSizeI
ndex3[/PARA] <
[PARA]TbSizeI
ndex4[/PARA]
- None RNC N (No impact on the UE in Not involv
1.This
parameter is
listed when the
value of
[PARA]TbNum[
/PARA] is D3 or
D4.
2.
[PARA]TbSizeI
ndex1[/PARA] <
[PARA]TbSizeI
ndex2[/PARA] <
[PARA]TbSizeI
ndex3[/PARA] <
[PARA]TbSizeI
ndex4[/PARA]
- None RNC N (No impact on the UE in Not involv
1.This
parameter is
listed when the
value of
[PARA]TbNum[
/PARA] is D4.
2.
[PARA]TbSizeI
ndex1[/PARA] <
[PARA]TbSizeI
ndex2[/PARA] <
[PARA]TbSizeI
ndex3[/PARA] <
[PARA]TbSizeI
ndex4[/PARA]
- None RNC N (No impact on the UE in Not involv
170 170 MTP3 None N (No impact on the UE in Not involv
- None Cell
None Y Cell
- None Cell This paramter is N (No impact on the UE in Not involv
10 10 MTP3 None N (No impact on the UE in Not involv
D60 D60 Cell This parameter N (No impact on the UE in Not involv
D20 D20 Cell This parameter N (No impact on the UE in Not involv
NotUsed NotUsed Cell This parameter N(impact on Cell Selection Not involv
NotUsed NotUsed Cell This parameter N(impact on Cell Selection Not involv
60(ADD Cell(ADD
CELLHCS CELLHCS
HO) 60 HO)
-(SET RNC(SET
HCSHO) HCSHO) None N (No impact on the UE in Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
- None SRB None Not involved Not involv
D3 D3 Cell
This parameter i N(For the UE in idle mode, Not involv
D2 D2 Cell
480(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 480 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
Valid when [PA N (no impact on the UE in Not involv
480(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 480 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
Valid when [PA N (no impact on the UE in Not involv
480(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 480 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
Valid when [PA N (no impact on the UE in Not involv
LDCPERIOD[/
MML] and
[MML]SET
SATLDCPERIO
D[/MML]);
[PARA]TenMse
cForDlBasicMea
s[/PARA] <
[PARA]LdrPerio
dTimerLen[/PA
RA] x 1000/2
(See [MML]SET
LDCPERIOD[/
MML] and
[MML]SET
SATLDCPERIO
20(SET LDM) D[/MML]);
- RNC
100(SET SATLDM) [PARA]TenMse
cForDlBasicMea
s[/PARA] <
[PARA]OlcPerio
dTimerLen[/PA
RA]/2 (See
[MML]SET
LDCPERIOD[/
MML] and
[MML]SET
SATLDCPERIO
D[/MML]).
This paramter is
valid only when
[PARA]ChoiceR
prtUnitForDlBas
icMeas[/PARA] N (No impact on the UE in Not involv
20(SET LDM)
- RNC
100(SET SATLDM) This paramter i N (No impact on the UE in Not involv
100(SET LDM)
10(ground
- circuit)/100(satellite RNC
transmission)(SET
SATLDM) This paramter i N (No impact on the UE in Not involv
- 100 RNC
This paramter i N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
(See [MML]SET
LDCPERIOD[/
MML] and
[MML]SET
SATLDCPERIO
D[/MML]);
[PARA]TenMse
cForUlBasicMea
s[/PARA] <
[PARA]OlcPerio
dTimerLen[/PA
20(SET LDM) RA] /2 (See
- RNC
100(SET SATLDM) [MML]SET
LDCPERIOD[/
MML] and
[MML]SET
SATLDCPERIO
D[/MML]) .
This paramter is
valid only when
[PARA]ChoiceR
prtUnitForUlBas
icMeas[/PARA] N (No impact on the UE in Not involv
20(SET LDM) is set to
- RNC
100(SET SATLDM) This paramter i N (No impact on the UE in Not involv
480(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) 480 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
Valid when [PA N (no impact on the UE in Not involv
Transport
- None
channel
None Not involved Not involv
- None RNC None Not involved Not involv
- 280 RNC Restriction: [ N (no impact on the UE in Not involv
- None RNC Restriction: [ N (no impact on the UE in Not involv
- None RNC Restriction: [ N (no impact on the UE in Not involv
- None RNC This parameter, N (No impact on the UE in Not involv
- Medium RNC None N (No impact on the UE in Not involv
- Low RNC None N (No impact on the UE in Not involv
- Low RNC None N (No impact on the UE in Not involv
- Low RNC None N (No impact on the UE in Not involv
- Low RNC None N (No impact on the UE in Not involv
- Low RNC None N (No impact on the UE in Not involv
- High RNC None N (No impact on the UE in Not involv
- High RNC None N (No impact on the UE in Not involv
- High RNC None N (No impact on the UE in Not involv
- High RNC None N (No impact on the UE in Not involv
- High RNC None N (No impact on the UE in Not involv
- Medium RNC None N (No impact on the UE in Not involv
- Medium RNC None N (No impact on the UE in Not involv
- Medium RNC None N (No impact on the UE in Not involv
- Medium RNC None N (No impact on the UE in Not involv
- None RNC This parameter N (No impact on the UE in Not involv
2000 2000 Ethernet por None Not involved Not involv
Ethernet
2 2
port None Not involved Not involv
- None Cell This paramter i Not involved Not involv
10 10 AAL2 Path None Y AAL2 Path
4 4 Ethernet por None Not involved Not involv
0 0 Cell None N (No impact on the UE in Not involv
- 0 RNC None N (No impact on the UE in Not involv
5000 5000 RAB This parameter N (No impact on the UE in Not involv
Cell(ADD
D0(ADD
CELLINT
CELLINTE
ERFREQH
RFREQHO
OCOV)
COV) D0
RNC(SET
-(SET
INTERFR
INTERFRE
EQHOCO
QHOCOV)
V)
-(SET
MBMSFAC
None(ADD FACH)
H,ADD
10(SET
FACH) Transport
MBMSFACH,ADD
10(ADD channel
CELLMBMSFACH,
CELLMBM
ADD PCH)
SFACH,AD
D PCH)
None N (No impact on the UE in Not involv
-(SET
MBMSFAC
None(ADD FACH)
H,ADD
35(SET
FACH) Transport
MBMSFACH,ADD
35(ADD channel
CELLMBMSFACH,
CELLMBM
ADD PCH)
SFACH,AD
D PCH)
None N (No impact on the UE in Not involv
1 1 Cell This paramter i N (No impact on the UE in Not involv
D0 D0 Cell
SAALLN
K/AAL2P
ATH/IPO
APVC/VP
CLCX
using this
ATM
- None
traffic
record
index(AD
D
ATMTRF)
Ethernet
port(RMV
ATMTRF)
None Not involved Not involv
Cell(ADD
D320(ADD CELLINT
D320(SET
CELLINTR RAFREQ
INTRAFREQHO,A
AFREQHO) HO)
DD
-(SET RNC(SET
CELLINTRAFREQ
SMLC,SET SMLC,SE
HO)
INTRAFRE T
D160(SET SMLC)
QHO) INTRAFR
EQHO)
Ethernet
port(ADD
ETHTRKL
NK)
- None
RNC(RM
V
ETHTRKL
NK)
None Not involved Not involv
Ethernet
port(ADD
ETHTRKL
NK)
- None
RNC(RM
V
ETHTRKL
NK)
None Not involved Not involv
Ethernet
port(ADD
ETHTRKL
NK,ADD
ETHTRKI
P,ADD
- None ETHTRK)
RNC(RM
V
ETHTRKI
P,RMV
ETHTRK)
None Not involved Not involv
50 50 Cell None N (No impact on the UE in Not involv
- None RNC This paramter is N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None LGC port None Not involved Not involv
- None Cell When the value Y Cell
- OFF E1T1 link When the value Not involved Not involv
PE[/PARA] in
[MML]ADD
PPP PPPLNK[/MML
Link(ADD ]is set to PEUa,
PPPLNK) the value
E1/T1 of[PARA]TSBIT
- None port(ADD MAP[/PARA]
FRALNK) must be set.
3.When the
RNC(ADD value of
MPLNK) [PARA]BRDTY
PE[/PARA] in
Not involved Not involv
[MML]ADD
- None E1/T1 None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
The value of the
parameter must
satisfy the
function below:
240(ADD Cell(ADD
[PARA]NFastSp
CELLHCS CELLHCS
dEst[/PARA]*[P
HO) 240 HO)
ARA]TSlowSpd
-(SET RNC(SET
Est[/PARA] >=
HCSHO) HCSHO)
[PARA]NSlowS
pdEst[/PARA]*[
PARA]TFastSpd
Est[/PARA].
- None Cell
None Y Cell
500 500 Ethernet por None Not involved Not involv
30 30 Ethernet por None Not involved Not involv
2.When the
value of
[PARA]CARRY
T[/PARA] in
IPoA [MML]ADD
PVC(ADD AAL2PATH[/M
IPOAPVC ML] is set to
) UNI, IMA,
AAL2 FRAATM,
Path(ADD NCOPT, or
AAL2PAT ATMLGCPORT
H) , this parameter
- None
is required.
SAAL(AD When the value
D of
SAALLN [PARA]CARRY
K) T[/PARA] in
[MML]ADD
RNC(ADD AAL2PATH[/M
VPCLCX) ML] is set to
UNI, IMA,
FRAATM,
NCOPT, or N (No impact on the UE in Not involv
- None control inte ATM
None logic port, Y ETHPORT/
- None Cell
None Y Cell
- None Cell
When [PARA]UARFC
Y Cell
- None Cell
None Y Cell
- 5000 RNC None N (No impact on the UE in Not involv
150 150 IP Path When the value N (No impact on the UE in Not involv
MUXCLOSEMUXCLOSE IP Path When the value N (No impact on the UE in Not involv
MUXCLOSEMUXCLOSE IP Path When the value N (No impact on the UE in Not involv
2 2 IP Path When the value N (No impact on the UE in Not involv
- None RNC None N (no impact on the UE in Not involv
- None RNC None N (no impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- 5000 RNC None N (No impact on the UE in Not involv
- None RNC None Not involved Not involv
1000 1000 E1T1 Link When the value Not involved Not involv
- None SRB None Not involved Not involv
- 50 RNC This paramter i N (No impact on the UE in Not involv
D320(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D320 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D320(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D320 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D320(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D320 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D320(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D320 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D240(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D240 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- 10 RNC This paramter i N (No impact on the UE in Not involv
D6(SET LDM)
- RNC
D3(SET SATLDM) None N (No impact on the UE in Not involv
RNC(SET
-(SET FRCCHLT
FRCCHLT YPEPARA
YPEPARA) D8 )
D8(ADD Cell(ADD
CELLFRC) CELLFRC
)
If this parame N (No impact on the UE in Not involv
- D64 RNC This parameter N (No impact on the UE in Not involv
- D608 RNC None N (No impact on the UE in Not involv
D640(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D640 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D1280(AD Cell(ADD
D CELLQU
CELLQUA ALITYME
LITYMEAS D1280 AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
D2560(AD Cell(ADD
D CELLQU
CELLQUA ALITYME
LITYMEAS D2560 AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
D1280(AD Cell(ADD
D CELLQU
CELLQUA ALITYME
LITYMEAS D1280 AS)
) RNC(SET
-(SET QUALITY
QUALITY MEAS)
MEAS)
None N (no impact on the UE in Not involv
D240(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D240 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlOlcTr
igThd[/PARA]
(See
[MML]ADD
CELLLDM[/M
ML]) >=
[PARA]UlCellT
otalThd[/PARA]
;
[PARA]UlCellT
otalThd[/PARA]
>
[PARA]UlNonCt
rlThdForHo[/PA
RA] .
83 83 Cell N (No impact on the UE in Not involv
SF/2 SF/2 NodeB None. N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
3 3
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
3 3
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
When the value
of
UlMidRateCalc
is
HAND_APPOIN
T,the following
relationship must
be satisfied:
[PARA]UlDccc
RateThd[/PARA
] <=
[PARA]UlMidR
ateThd[/PARA].
- D64 RNC N (no impact on the UE in Not involv
- SILENT RAB None. N (No impact on the UE in Not involv
D64(ADD Cell(ADD
CELLDCC CELLDCC
C) D64 C)
-(SET RNC(SET
DCCC) DCCC) This parameter N (no impact on the UE in Not involv
([PARA]UserPri
- D64 RNC ority[/PARA] is N (No impact on the UE in Not involv
set to GOLD) >=
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlHoCe
ResvSf[/PARA]
>=
[PARA]UlLdrCr
editSfResThd[/P
ARA] .
SF16 SF16 Cell N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
- SCHEDULED RNC None N (No impact on the UE in Not involv
- 10 RNC This paramter i N (No impact on the UE in Not involv
200000 200000 Cell None N (No impact on the UE in Not involv
20 20 Cell None N (No impact on the UE in Not involv
1 1 Cell None N (No impact on the UE in Not involv
- 5 RNC
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
SF8 SF8
NodeB(A
DD
NODEBL
DR)
The value of thi N (No impact on the UE in Not involv
no action no action Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
inter-freq
load
Cell(ADD
handover(A
inter-freq load CELLLDR
DD
handover(ADD )
CELLLDR)
CELLLDR)
BE traff
BE traff rate NodeB(A
rate
reduction(ADD DD
reduction(A
NODEBLDR) NODEBL
DD
DR)
NODEBLD
R)
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlLdrTr
igThd[/PARA]
>=
[PARA]UlLdrRe
lThd[/PARA];
[PARA]UlOlcRe
lThd[/PARA] >=
[PARA]UlLdrRe
lThd[/PARA].
45 45 Cell N (No impact on the UE in Not involv
BE traff
Cell(ADD
rate
CELLLDR
reduction(A BE traff rate
)
DD reduction(ADD
CELLLDR) CELLLDR)
NodeB(A
no no action(ADD
DD
action(ADD NODEBLDR)
NODEBL
NODEBLD
DR)
R)
None N (No impact on the UE in Not involv
no action no action Cell None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
no action no action
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
55 55 Cell [PARA]UlOlcTr N (No impact on the UE in Not involv
igThd[/PARA] >
D64 D64 NodeB None. N (No impact on the UE in Not involv
D19(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D19 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- HAND_APPOINT RNC The parameter N (no impact on the UE in Not involv
The parameter
is valid when
[PARA]UlMidR
ateCalc[/PARA]
in [MML]SET
DCCC[/MML] is
set to
HAND_APPOIN
T, and the
following
relationship must
be satisfied:
[PARA]UlDccc
RateThd[/PARA
] <=
[PARA]UlMidR
ateThd[/PARA].
- D128 RNC N (no impact on the UE in Not involv
The following
relationship must
be satisfied:
[PARA]UlMode
- 1000 RNC ChangeTimerLe
n[/PARA] <=
[PARA]DlMode
ChangeTimerLe
n[/PARA].
N (no impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlNonCt
rlThdForHo[/PA
RA] >
[PARA]UlNonCt
rlThdForAMR[/
PARA];
[PARA]UlNonCt
rlThdForAMR[/
PARA] >
[PARA]UlNonCt
rlThdForOther[/
PARA].
75 75 Cell N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlCellT
otalThd[/PARA]
>
[PARA]UlNonCt
rlThdForHo[/PA
RA] ;
[PARA]UlNonCt
rlThdForHo[/PA
RA] >
[PARA]UlNonCt
rlThdForAMR[/
PARA];
[PARA]UlNonCt
rlThdForHo[/PA
RA] >
[PARA]UlNonCt
rlThdForNonAM
R[/PARA] .
- D1 RNC
None N (No impact on the UE in Not involv
The value of
this parameter
must satisfy the
following
relationship:
[PARA]UlOlcTr
igThd[/PARA]
>=
[PARA]UlOlcRe
lThd[/PARA];
[PARA]UlOlcRe
lThd[/PARA] >=
[PARA]UlLdrRe
lThd[/PARA].
85 85 Cell N (No impact on the UE in Not involv
0 0 Cell None N (No impact on the UE in Not involv
- 100 RNC
None N (No impact on the UE in Not involv
igThd[/PARA]
95 95 Cell >= N (No impact on the UE in Not involv
[PARA]UlOlcRe
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
Cell(ADD
CELLLDR
)
1 1
NodeB(A
DD
NODEBL
DR)
None N (No impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
20(ADD Cell(ADD
CELLQOS CELLQOS
HO) 20 HO)
-(SET RNC(SET
QOSHO) QOSHO) None N (No impact on the UE in Not involv
- NO RNC Valid when [PAR N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- NO RNC Valid when [PA N (no impact on the UE in Not involv
- 3_Rates RNC None N (no impact on the UE in Not involv
- 3_Rates RNC None N (no impact on the UE in Not involv
D64(ADD Cell(ADD
CELLCMC CELLCM
F) D64 CF)
-(SET RNC(SET
CMCF) CMCF) None N (No impact on the UE in Not involv
- 10 RNC This paramter i N (No impact on the UE in Not involv
- SCHEDULED RNC None N (No impact on the UE in Not involv
- 100 RNC This paramter i N (No impact on the UE in Not involv
- D256 RNC None. N (No impact on the UE in Not involv
- NON-SCHEDULED RNC None N (No impact on the UE in Not involv
- None RNC Restriction: [ N (no impact on the UE in Not involv
Restrictions:
1)
[PARA]UlThd6
A2[/PARA] <=
[PARA]UlThd6
B2[/PARA];
2)
[PARA]UlThd6
A2[/PARA] >
[PARA]UlThd6
B1[/PARA]
- None RNC N (no impact on the UE in Not involv
Restrictions:
1)
[PARA]UlThd6
A1[/PARA] <=
[PARA]UlThd6
B1[/PARA];
2)
[PARA]UlThd6
A2[/PARA] >
[PARA]UlThd6
B1[/PARA]
- None RNC N (no impact on the UE in Not involv
- None RNC Restriction: [ N (no impact on the UE in Not involv
80 80 Cell None N (No impact on the UE in Not involv
- 1 RNC This parameter N (No impact on the UE in Not involv
D640(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D640 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D640(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D640 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
D240(ADD Cell(ADD
CELLQUA CELLQU
LITYMEAS ALITYME
) D240 AS)
-(SET RNC(SET
QUALITY QUALITY
MEAS) MEAS)
None N (no impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
- None Cell Valid when [PA N (no impact on the UE in Not involv
Valid when
[PARA]CellLoc
CfgType[/PARA
] is set to BOTH
or
CELL_CENTER
;
[PARA]UncertS
emiMajor[/PAR
A]>=[PARA]Un
certSemiMinor[/
PARA].
- None Cell N (no impact on the UE in Not involv
Valid when
[PARA]CellLoc
CfgType[/PARA
] is set to BOTH
or
CELL_CENTER
;
[PARA]UncertS
emiMajor[/PAR
A]>=[PARA]Un
certSemiMinor[/
PARA].
Valid when
[PARA]CellLoc
CfgType[/PARA
] is set to BOTH
or
CELL_CENTER
;
[PARA]UncertS
emiMajor[/PAR
A]>=[PARA]Un
certSemiMinor[/
PARA].
- None Cell N (no impact on the UE in Not involv
Valid when
[PARA]CellLoc
CfgType[/PARA
] is set to BOTH
or
CELL_CENTER
;
[PARA]UncertS
emiMajor[/PAR
A]>=[PARA]Un
certSemiMinor[/
PARA].
Cell(ADD
CELLUR
A,ADD
URA)
- None
RNC(ADD
NRNCUR
A)
None N (No impact on the UE in Not involv
- None Cell None Not involved Not involv
Cell(ADD
-12(ADD CELLINT
CELLINTE ERRATH
RRATHOC OCOV,AD
OV,ADD D
CELLINTE CELLINT
RFREQHO ERFREQH
COV) -12 OCOV)
-(SET RNC(SET
INTERRAT INTERRA
HOCOV,SE THOCOV,
T SET
INTERFRE INTERFR
QHOCOV) EQHOCO
V)
This paramete N (No impact on the UE in Not involv
Cell(ADD
-92(ADD
CELLINT
CELLINTE
ERRATH
RFREQHO -92(SET
OCOV,AD
COV) INTERFREQHOCO
D
-(SET V,ADD
CELLINT
INTERRAT CELLINTERFREQH
ERFREQH
HOCOV,SE OCOV)
OCOV)
T -97(SET
RNC(SET
INTERFRE INTERRATHOCOV
INTERRA
QHOCOV) ,ADD
THOCOV,
-97(ADD CELLINTERRATH
SET
CELLINTE OCOV)
INTERFR
RRATHOC
EQHOCO
OV)
V)
This paramete
OVERLAY_SW N (No impact on the UE in Not involv
ITCH is in
[PARA]HoSwitc
Cell(ADD
-12(ADD h[/PARA] in
CELLINT
CELLINTE [MML]SET
ERRATH
RFREQHO -12(SET CORRMALGOS
OCOV,AD
COV) INTERFREQHOCO WITCH[/MML].
D
-(SET V,ADD This parameter
CELLINT
INTERRAT CELLINTERFREQH is valid when the
ERFREQH
HOCOV,SE OCOV) OVERLAY_SW
OCOV)
T -13(SET ITCH is ON The
RNC(SET
INTERFRE INTERRATHOCOV OVERLAY_SW
INTERRA
QHOCOV) ,ADD ITCH is in
THOCOV,
-13(ADD CELLINTERRATH [PARA]HoSwitc
SET
CELLINTE OCOV) h[/PARA] in
INTERFR
RRATHOC [MML]SET
EQHOCO
OV) CORRMALGOS
V)
WITCH[/MML]
and
OVERLAY_SW N (No impact on the UE in Not involv
[PARA]MeasQu
ITCH is in
[PARA]HoSwitc
Cell(ADD
-92(ADD h[/PARA] in
CELLINT
CELLINTE [MML]SET
ERRATH
RFREQHO -92(SET CORRMALGOS
OCOV,AD
COV) INTERFREQHOCO WITCH[/MML].
D
-(SET V,ADD This parameter
CELLINT
INTERRAT CELLINTERFREQH is valid when the
ERFREQH
HOCOV,SE OCOV) OVERLAY_SW
OCOV)
T -107(SET ITCH is ON The
RNC(SET
INTERFRE INTERRATHOCOV OVERLAY_SW
INTERRA
QHOCOV) ,ADD ITCH is in
THOCOV,
-107(ADD CELLINTERRATH [PARA]HoSwitc
SET
CELLINTE OCOV) h[/PARA] in
INTERFR
RRATHOC [MML]SET
EQHOCO
OV) CORRMALGOS
V)
WITCH[/MML]
and N (No impact on the UE in Not involv
[PARA]MeasQu
CPICH_RS Cell(ADD
CP(ADD CELLQOS
CELLQOS CPICH_RSCP HO)
HO) RNC(SET
-(SET QOSHO)
QOSHO)
Cell(ADD
-12(ADD
CELLINT
CELLINTE
ERRATH
RFREQHO -12(SET
OCOV,AD
COV) INTERFREQHOCO
D
-(SET V,ADD
CELLINT
INTERRAT CELLINTERFREQH
ERFREQH
HOCOV,SE OCOV)
OCOV)
T -13(SET
RNC(SET
INTERFRE INTERRATHOCOV
INTERRA
QHOCOV) ,ADD
THOCOV,
-13(ADD CELLINTERRATH
SET
CELLINTE OCOV)
INTERFR
RRATHOC
EQHOCO
OV)
V)
This paramete N (No impact on the UE in Not involv
Cell(ADD
-92(ADD
CELLINT
CELLINTE
ERRATH
RFREQHO -92(SET
OCOV,AD
COV) INTERFREQHOCO
D
-(SET V,ADD
CELLINT
INTERRAT CELLINTERFREQH
ERFREQH
HOCOV,SE OCOV)
OCOV)
T -107(SET
RNC(SET
INTERFRE INTERRATHOCOV
INTERRA
QHOCOV) ,ADD
THOCOV,
-107(ADD CELLINTERRATH
SET
CELLINTE OCOV)
INTERFR
RRATHOC
EQHOCO
OV)
V)
This paramete N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
Disable Disable RNC None N (No impact on the UE in Not involv
Cell(ADD
GSMCEL
L,ADD
CELLHCS
NOT_USE
NOT_USED )
D
RNC(ADD
NRNCCE
LL)
None N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
ALL_USER ALL_USER Cell None N (No impact on the UE in Not involv
- 5 RNC None N (No impact on the UE in Not involv
- 90 RNC None N (No impact on the UE in Not involv
This parameter,
[PARA]TrafficC
lass[/PARA],
[PARA]THP[/P
ARA], and
[PARA]SPI[/PA
RA] form an SPI
mapping table.
- None RNC
This parameter is
not required
when the
[PARA]TrafficC
lass[/PARA]
parameter is set
to IMS or SRB.
None.
N (No impact on the UE in Not involv
- None RNC None N (No impact on the UE in Not involv
- None SAALLNK/AANone Not involved Not involv
- None AAL2 Path When the value Y AAL2 Path
- CC PVC When the value Not involved Not involv
SCTP(AD
D
SCTPLNK
DISABLE DISABLE
)
IP
Path(ADD
IPPATH)
This parameter Y Services th
When the value
of
[PARA]VLANFl
AG[/PARA] in
RNC(ADD [MML]ADD
VLANID) IPPATH[/MML]
IP is set to
Path(ADD ENABLE, this
IPPATH) parameter is
valid.
- None
SCTP(AD When the value
D of
SCTPLNK [PARA]VLANFl
) AG[/PARA] in
Ethernet [MML]ADD
port(ADD SCTPLNK[/MM
ETHMA) L] is set to
ENABLE, this
parameter is
valid.
- None RNC
None Not involved Not involv
- None AAL2 Path When the value Y AAL2 Path
FALSE FALSE RNC None N (No impact on the UE in Not involv
Cell(ADD
0(ADD
CELLINT
CELLINTR
RAFREQ
AFREQHO)
0 HO)
-(SET
RNC(SET
INTRAFRE
INTRAFR
QHO)
EQHO)
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved This parameter c Read & Write Transport
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved This parameter c Read & Write Radio
Not involved When the networkRead & Write Transport
Not involved The parameter moRead & Write Radio
Not involved This parameter c Read & Write Transport
Not involved This parameter c Read & Write Transport
The services are The checksum calRead & Write Transport
The services are The checksum calRead & Write Transport
The services are The checksum calRead & Write Transport
Not involved This parameter c Read & Write Transport
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved This parameter i Read & Write Transport
Not involved Modifiying this pRead & Write Transport
Not involved Modifying this p Read & Write Transport
Not involved Modifiying this pRead & Write Transport
Not involved Modifying this p Read & Write Transport
Not involved Modifiying this pRead & Write Transport
Not involved Modifiying this pRead & Write Transport
Not involved The parameter moRead & Write Equipment
The services are inThe cell should bRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved This parameter c Read & Write Transport
Not involved This parameter c Read & Write Transport
Not involved This parameter c Read & Write Equipment
The services are inThe cell should bRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The IP address o Read & Write Transport
The services are inThe cell should bRead & Write Radio
Not involved This parameter c Read & Write Equipment
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Equipment
The services are inThe cell should bRead & Write Radio
The services are The addresses of Read & Write Transport
The services are The addresses of Read & Write Transport
The services are The SCTP port nuRead & Write Transport
Not involved The parameter moRead & Write Equipment
The services are This parameter i Read & Write Transport
The services are This parameter i Read & Write Transport
The services are This parameter i Read & Write Transport
Not involved The parameter caRead & Write Equipment
Not involved The parameter caRead & Write Equipment
interrupted until
the link
loopback is
cancelled.
If the uplink is
beared by
IMAGRP, the
IMAGRP must
The loopback keeps be reset after the Read & Write Transport
Not involved The parameter moRead & Write Transport
Not involved This parameter c Read & Write Equipment
If the SCTP
link is set to
SERVER and
the application
type is NBAP,
the working
mode cannot be
changed to
CLIENT.
For the SCTP
link whose
application type
is M3UA, the
working mode
can be modified
only when the
upper-layer
application is
deleted.
1. When the
parameter is set
to OFF, the MR
function is
disabled.
2. The
modification of
this parameter
has no impact on
the equipment.
Not involved Read & Write Radio
Not involved The parameter moRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
The services are The parameter moRead & Write Transport
Not involved If the transport Read & Write Transport
Not involved If the transport Read & Write Transport
Not involved The parameter moRead & Write Radio
Not involved The IP address o Read & Write Transport
Not involved The IP address o Read & Write Transport
Not involved When this parameRead & Write Equipment
Not involved When this parameRead & Write Equipment
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved Modifiying this pRead & Write Transport
Not involved Modifiying this pRead & Write Transport
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Equipment
Not involved This parameter c Read & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The parameter moRead & Write Transport
Not involved This parameter c Read & Write Transport
Not involved This parameter c Read & Write Transport
If the mode is not This parameter c Read & Write Transport
The services are inThe cell should bRead & Write Radio
The services are inThe cell should bRead & Write Radio
The services are inThe cell should bRead & Write Radio
Not involved The modificationRead & Write Transport
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Transport
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Transport
Not involved This parameter c Read & Write Transport
Not involved This parameter c Read & Write Equipment
Not involved The parameter moRead & Write Radio
Not involved The parameter moRead & Write Radio