Вы находитесь на странице: 1из 18

We measure it.

Flue gas analysis – brilliantly easy: testo 350


– the first flue gas analyzer that thinks ahead
testo 350 We measure it.

The new flue gas analyzer testo 350


offers advantages and real benefits – as you can see!
• Innovative: The application-guided operation with helpful instrument pre-settings
• Elegant and clear: The large colour graphic display
• Robust design: The sealed housing makes the testo 350 insensitive to knocks and dirt
• Cost and time-savings: The new service concept offers fast access to wearing parts

˚
Control Unit
controls the analyzer box
Analyzer box and displays the measure-
ment values
robust, stable housing with
integrated rubber edges,
protects the sensors,
pumps, analysis and
memory electronics

The status display shows


the current operational sta-
tus, visible from a distance

¸
Colour graphic display
innovative operating convenience
thanks to an easy, clear menu
structure

The connections are of industrial standard thanks


05.05.10 09:06
to new, mechanically robust connection sockets Testo AG/Process
Natural gas Exhaust gas
The dirt filters are easily Burner
accessible and can be chan- Turbine
ged without the use of tools Engine l > 1

Engine l ≤ 1

User-defined

Options OK

2
testo 350

The new flue gas analyzer testo 350 offers


insights and creates transparency ...

Li-ion battery,
mains-independent
˝Service opening
power supply for seve-
ral hours

Output of
external
cooling loop

The measurement
˛ gas pump
Sensor chamber transports the gas
to the gas sensors

Input of
external
cooling loop


ˇGas sensors Condensate container
The fresh air and dilution The condensate pump
pump provides the gas transports occurring
sensors with fresh air as condensate into the
required condensate container

Plug & play: Easy gas sensor replacement Condensate container: Condensate container quickly and easily
emptied

3
testo 350 – Flue gas measurement at the highest level, thanks to:

˝Easily accessible service opening External cooling loop


The service opening in the underside of the instrument allows very easy Closed cooling loops isolate the instrument electronics and sensors from
access to all relevant service and wearing parts such as pumps and filters, the ambient air. The interior of the instrument is cooled via a heat exchan-
which can then be quickly cleaned and/or exchanged on site. The advan- ger and therefore does not come into contact with dirty or aggressive
tages: ambient air.
3 Reduction of instrument unavailability due to service times. 3 Damage to the internal electronics are thus effectively prevented.
3 Cost savings due to instrument maintenance and/or exchange and cle- 3 The instrument can also be safely used in dusty or dirty atmospheres
aning of wearing parts by the user.
3 Immediate access to all relevant wearing parts
Further advantages...
˛Thermally separated sensor chamber Diagnosis function – integrated and intelligent
The sensor chamber is thermally separated from the other instrument
components. This reduces possible sensor drifts caused by thermal The testo 350 has a number of instrument diagnosis functions. Error
influences. reports are issued in clear text, and are thus easily understandable. The
This allows the maximum reliability pf the measuring instrument to be current status of the flue gas analyzer is constantly displayed.
achieved. This guarantees:
3 Low downtimes thanks to early warning reports, for example when gas
sensors are spent.
ˇEasy exchange of the gas sensors 3 No false measurements due to faulty instrument components.
The gas sensors are pre-calibrated and can be exchanged, replaced or 3 Better planning of measurement work
extended by further measurement parameters without test gas – 3 More reliability in emission measurement and up-to-date information on
if necessary directly at the measurement site. the instrument status.

3 No more long service times


3 Flexible extension of the testo 350 by further gas measurement Automatic zeroing of the pressure sensor
parameters when applications or regulations change. This option allows volume and mass flow velocity to be measured without
3 A report is immediately issued when the NO sensor filter is used up. supervision over a longer period of time and parallel to the emission mea-
Then only the filter needs to be changed, and no longer the whole NO surement. The pressure sensor is automatically zeroed at regular intervals.
sensor. This avoids the typical drift of the pressure sensor when ambient condi-
tions change.

— Automatically monitored condensate trap


The automatic monitoring of filling level reports when the condensate con- Gas sensor zeroing
tainer needs to be emptied, and a few minutes after the report, the When the instrument is switched on, or manually if needed, the gas sen-
measurement gas pump is automatically stopped. This provides the hig- sors are zeroed with ambient air. In the testo 350, this procedure is
hest protection of the analyzer box and the gas sensors from damage by already completed in 30 seconds. This means that fast availability with
condensate entry. tested and zeroed gas sensors is always guaranted.

Filters can be easily exchanged Service opening with easy access Continuous condensate drain-off Control unit connections
without tools to wearing parts for long -term measurements

4
We measure it.

Flue gas analysis – brilliantly easy: testo 350, the only one that thinks ahead!

The portable flue gas analyzer testo 350 is the ideal tool for professional Typical fuels, a practicable order of the exhaust gas parameters in the dis-
flue gas analysis. Helpful instrument settings guide the user safely through play, the corresponding calculations as well as useful instrument
typical measurement tasks such as: pre-settings, are stored under each of these measurement objects. Exam-
ples of these are the activation of the dilution in measurements on l ≤ 1
3 Flue gas analysis in commissioning, setting, optimization or operational
regulated industrial engines and gas turbines, or the testing of the relevant
measurements on industrial burners, stationary industrial engines, gas
gas sensor in the dilution slot.
turbines and flue gas purification systems.
3 Control and monitoring of officially prescribed emission limits in exhaust The advantages of the application-specific menu
gas.
3 Information in the display guides the user through the menu.
3 Function testing of stationary emission measuring instruments.
3 Easy operation without previous knowledge of the instrument
3 Control and monitoring of defined gas atmospheres in furnace rooms or
3 Reduction of the work steps before the start of the measurement.
kilns in different processes.

Analyzer box – industrial standard, robust and reliable


˚ Control unit – small and convenient
In the analyzer box are the gas sensors, the measurement gas and rinsing
The control unit is the operating and display unit of the testo 350. It can
pumps, the Peltier gas preparation (optional), gas paths, filters, analysis
be removed and equipped as standard with a Li-ion rechargeable battery.
and storage electronics as well as the mains unit and the Li-ion battery.
All settings are carried out using the cursor button. The presentation of the
measurement values takes place via the colour graphic display. Thanks to The robust housing has built-in impact protection (specially constructed
the internal memory, measurement data can be transferred from the ana- X-shaped rubber edges), allowing the analyzer box to be used in tough
lyzer box to the control unit. If required by the measurement, several conditions. Downtimes due to dirt in the instrument are almost completely
analyzer boxes can conveniently be operated and controlled using one eliminated by intelligent design and robustness. Inherently sealed cham-
control unit bers protect the interior of the instrument from dirt from the surroundings.
Operation can be carried out with the control unit or in direct connection
The advantages of the testo 350 control unit: ® 2.0 oder CANCase). The analy-
with a PC or notebook (USB, Bluetooth
3 Operation of the analyzer box and transfer of the measurement data zer box can, after programming, independently carry out measurements
even when the flue gas pipe and the adjustment site are separated, and store measurement data.
especially helpful for industrial burners, for example.
The plug-in connections for the probes and bus cables are locked by bay-
3 Measurement data can be transferred from the analyzer box to the con-
onet fittings, and therefore securely connected to the analyzer box. This
trol unit. This means the analyzer box can remain at the measurement
prevents unintentional removal, avoiding false measurements.
site for further measurements, and the control unit taken away in order
to process the measurement data. The advantages of the analyzer box
3 In order to protect the display in measurements over a longer period or 3 Special chambers offer comprehensive protection for the sensors and
during transport to different measurement sites in a system, the control electronics from dust and deposits.
unit can be attached to the analyzer box face-down.

¸ Large colour graphic display with


application-specific menu
The following measurement objects are available:
• Burner
• Gas turbine
• Engines (Select l > 1 orl ≤ 1 regulated industrial engines)
User-defined.

Control unit is simply clicked in Control unit turned over: safe trans- Robust flue gas analyzer for industrial use, even under the toughest condi-
port to the measurement site tions

5
testo 350
testo 350

Ideal order suggestion for emission measurement on industrial engines

Part no.
testo 350 Control Unit 0632 3511
Option BLUETOOTH® wireless transmission
testo 350 Analyzer box 0632 3510
Option CO (H2-compensated) sensor, 0 to 10000 ppm
Option NO sensor, 0 to 4000 ppm, resolution 1 ppm
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Option CxHy sensor (Pellistor)
Option Peltier gas preparation incl. hose pump
Option BLUETOOTH® wireless transmission
Option fresh air valve for long-term measurement, incl.
measuring range extension with dilution factor 5 for all
sensors
Option measuring range extension for individual slot
with the following selectable dilution factors:
0, 2, 5, 10, 20, 40
Flue gas probe for industrial engines, probe shaft 0600 7550
length 335 mm, incl. cone, heat protection shield, spe-
cial hose for NO2-/SO2 measurement, Tmax probe
shaft 1000 °C, hose length 2.2 m
Set BLUETOOTH® printer with wireless Bluetooth inter- 0554 0553
face, incl. 1 roll of thermal paper, rech. battery, mains unit
easyEmission software 0554 3334
100-240 V AC / 6.3 V DC international mains unit 0554 1096
Transport case for safe and tidy storage for flue gas 0516 3510
analyzer testo 350, gas sampling probe and accesso-
ries, dimensions 570 x 470 x 210 mm (LxWxH)

Ideal order suggestion for emission measurement on burners

Part no.
testo 350 Control Unit 0632 3511
Option BLUETOOTH® wireless transmission
testo 350 Analyzer box 0632 3510
Option CO (H2-compensated) sensor, 0 to 10000 ppm
resolution 1 ppm)
Option NO sensor, 0 to 4000 ppm, resolution 1 ppm
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Option SO2 sensor, 0 to 5000 ppm, resolution 1 ppm
Option Peltier gas preparation incl. hose pump
Option BLUETOOTH® wireless transmission
Option measuring range extension for individual slot
with the following selectable dilution factors:
0, 2, 5, 10, 20, 40
Gas sampling probe, modular, incl. special hose for 0600 8764
NO2-/SO2 measurement, cone, thermocouple NiCr-Ni
(TI), probe shaft length 335 mm, Tmax probe shaft
1000 °C, hose length 2.2 m
100-240 V AC / 6.3 V DC international mains unit 0554 1096
Transport case for safe and tidy storage for flue gas 0516 3510
analyzer testo 350, gas sampling probe and accesso-
ries, dimensions 570 x 470 x 210 mm (LxWxH)
Advantages in emission measurement on industrial engines
3 Highly accurate NOx measurement 3Special instrument menu for the testing of exhaust gas pre-
The testo 350 allows the separate measurement of NO and NO2. The high paration systems
and fluctuating NO2 components in engine exhaust gas make this measu- This exhaust gas menu allows the simultaneous measurement of exhaust
rement necessary, in order to display the real NOx value of the engine. In gas concentrations before and after the catalytic converter. For this purpo-
addition to this, the integrated gas preparation and the exhaust gas probe se, two analyzer boxes are connected to each other with the Testo
with a special hose provide protection from NO2 and SO2 absorption. databus cable. The measurement values of the two analyzer boxes are
shown parallel to each other in the control unit's display, enabling a fast
3Automatic measurement range extension for unexpectedly overview of the status of the converter.
high CO concentrations
In measurements on unfamiliar systems, or under less than ideal operating 3 Spatial distances
conditions, unexpectedly high emission values (e.g. CO concentrations up For greater distances between the gas sampling site and the adjustment
to 50,000 ppm) can occur. In these cases, the measurement range exten- site, the control unit can be connected with the analyzer box either via the
sion is automatically activated. This means maximum sensor life. These Testo databus cable or by Bluetooth®
useful pre-settings are already stored application-specifically in the instru-
ment – the testo 350 thinks ahead! testo 350: Flue gas analysis

05.05.10 09:06 05.05.10 09:06 05.05.10 09:06 05.05.10 09:06


Testo AG/Gas engine Testo AG/Gas engine Testo AG/Gas engine Testo AG/Gas engine
Natural gas Flue gas Natural gas Flue gas Natural gas Flue gas Natural gas 05.05.10 09:06
Measurement Measurement Measurement type Ready Testo AG/Gas engine
Natural gas
Coke oven gas
Flue gas Burner
Flue gas Town gas
Turbine
(before + after cat.) Diesel
Flue gas + m/s Engine λ > 1
Natural gas
Flue gas + ∆P Engine λ ≤ 1
Natrual gas H User-defined
Draught measurement

Options Options OK Coeff. OK Change list

Options OK

5. Documentation 4. Start measurement 3. Exhaust gas selection 2. Fuel selection 1. Application selection
05.05.10 09:06 05.05.10 09:06 05.05.10 09:06 05.05.10 09:06
Testo AG/Burner Testo AG/Burner Testo AG/Burner Testo AG/Burner
Light fuel oil Flue gas Light fuel oil Flue gas Light fuel oil Flue gas Light fuel oil 05.05.10 09:06
Measurement Measurement Measurement type Ready Testo AG/Burner
Light fuel oil
Light fuel oil
Flue gas Burner
Flue gas Heavy fuel oil
(before + after cat.) Turbine
Natural gas
Flue gas + m/s Engine λ > 1
LPG
Flue gas + ∆P Enginer λ ≤ 1
Wood 15%w
User-defined
Draught measurement
Briquette
Options Options OK Coeff. OK Change list

Options OK

Advantages in emission measurement on burners


3 High availability even under difficult conditions 3 Helpful instrument pre-settings save time
The instrument diagnosis as well as warning reports in clear text inform Typical fuels, a practicable order of the exhaust gas parameters in the dis-
the user of the current status of the flue gas analyzer. The large service play as well as useful instrument pre-settings are stored under each
opening in the testo 350 provides easy access to all relevant wearing application (selection list in display. Information in the display guides the
parts such as sensors, filters and pumps. This means they can be quickly user through the menu, previous familiarity with the instrument is not
and easily cleaned or exchanged on site. The pre-calibrated sensors allow necessary. The testo 350 is ready for use after only a few minutes.
the exchange of sensors without test gas. 3 Unrestricted measurement at high concentrations
When commissioning burners and in measurements on unfamiliar sys-
3 High measurement accuracy even in unsupervised measurements
tems, very high concentrations can take the user by surprise. In these
The integrated gas preparation prevents condensate from entering the
measuring instrument and damaging it. Condensate which occurs is auto- cases, the automatic measuring range extension is activated.
matically pumped off by a peristaltic pump. In addition to this, the gas
preparation and the PTFE hose in the gas sampling probe avoid NO2 and
SO2 absortion 0 this makes highly accurate measurements possible.

6
Advantages in emission measurement on gas turbines
3 Easy, precise test gas adjustment by the user 3 Highly accurate NOx measurements at low concentrations
In order to fulfil the highest accuracy and comparability requirements, the Emission measurement during monitoring and adjustment work on Low-
testo 350 can, if needed, be adjusted using test gas on site. NOx gas turbines requires a very high level of measurement accuracy
because of the low NO concentrations. Thanks to the combination of the
3 Use under tough conditions
NO2 sensor and the special NOlow sensor with a resolution of 0.1 ppm,
Special chambers and closed cooling loops isolate the instrument electro-
exactly these requirements are fulfilled. In addition to this, the integrated
nics and sensors from the ambient air. This means the sensor chamber is
gas preparation and the special exhaust gas probe for industrial engines
thermally separated from the other instrument components, and possible
with a special hose provides protection from NO2 absorption.
drift of the sensors due to thermal influences are reduced.
3 Combination of measuring range extension and COlow
sensor
Thanks to the freely selectable dilution levels, concentrations of up to a
maximum of 20,000 ppm can also be measured without any problems
with the COlow sensor (measuring range 500 ppm).
in only 5 steps

05.05.10 09:06 05.05.10 09:06 05.05.10 09:06 05.05.10 09:06


Testo AG/Gas turbine Testo AG/Gas turbine Testo AG/Gas turbine Testo AG/Gas turbine
05.05.10 09:06 Natural gas Natural gas Flue gas Natural gas Flue gas Natural gas Flue gas
Testo AG/Gas turbine Ready Measurement type Measurement Measurement
Natural gas
Light fuel oil
Burner Flue gas
Natural gas Flue gas
Turbine
Town gas (before + after cat.)
Engine λ > 1 Flue gas + m/s
Coke oven gas
Engine λ ≤ 1 Flue gas + ∆P
User-defined
Draught measurement

Coeff. OK Change list Options OK Options

Options OK

1. Application selection 2. Fuel selection 3. Exhaust gas selection 4. Start measurement 5. Documentation

05.05.10 09:06 05.05.10 09:06 05.05.10 09:06 05.05.10 09:06


Testo AG/Process Testo AG/Process Testo AG/Process Testo AG/Process
05.05.10 09:06 Natural gas Natural gas Flue gas Natural gas Flue gas Natural gas Flue gas
Testo AG/Process Ready Measurement type Measurement Measurement
Natural gas
Light fuel oil
Burner Flue gas
Heavy fuel oil Flue gas
Turbine (before + after cat.)
Natural gas
Engine λ > 1 Flue gas + m/s
LPG
Enginer λ ≤ 1 Flue gas + ∆P
User-defined Lignite
Draught measurement
Anthracite
Coeff. OK Change list Options OK Options

Options OK

Advantages in emission measurement in thermal processes


3 Excellently suited to long-term measurements 3 Ideal for measurements at high concentrations
Controlled by defined measurement procedures, processes/furnace Especially when recording extreme concentrations up to the % range, the
cycles can be monitored and analyzed over several days. The testo 350 measuring range extension is automatically activated. This allows the con-
conducts the measurements and saves the data in its internal store. The tinuation of the measurement. The gas sensor is placed under no greater
control can also be carried out directly via a PC and the easyEmission load than at low concentrations, a maximum sensor life is achieved –
without additional costs for further gas sensors.
software.
3 Industrial standard instrument functions for more security
3 Simultaneous exhaust gas analysis at different measure-
Inherently closed cooling loops isolate the instrument's electronics and
ment sites sensor from the ambient air. This means using the testo 350 in dusty or
In order to create a simultaneous profile of the furnace atmosphere and dirty surroundings is no problem. The impact protection integrated into the
the combustion zones in large systems, up to 16 analyzer boxes can be housing protects the testo 350 from knocks and jars on the way to the
connected with each other into a measurement system using the Testo measurement site.
databus cable. The control and operation can be carried out optionally eit-
her via the control unit or directly via a PC/notebook.

7
We measure it.

Ideal order suggestion for emission measurement on gas turbines

Part no.
testo 350 Control Unit 0632 3511
Option BLUETOOTH® wireless transmission
testo 350 Analyzer box 0632 3510
Option COlow (H2-compensated) sensor, 0 to 500 ppm,
resolution 0.1 ppm
Option NOlow-Sensor, 0 to 300 ppm, resolution
0.1 ppm
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Option Peltier gas preparation incl. hose pump
Option BLUETOOTH® wireless transmission
Option fresh air valve for long-term measurement, incl.
measuring range extension with dilution factor 5 for all
sensors
Option measuring range extension for individual slot
with the following selectable dilution factors:
0, 2, 5, 10, 20, 40
Flue gas probe for industrial engines, probe shaft 0600 7550
length 335 mm, incl. cone, heat protection shield, spe-
cial hose for NO2-/SO2 measurement, Tmax probe
shaft 1000 °C, hose length 2.2 m
100-240 V AC / 6.3 V DC international mains unit 0554 1096
Transport case for safe and tidy storage for flue gas 0516 3510
analyzer testo 350, gas sampling probe and accesso-
ries, dimensions 570 x 470 x 210 mm (LxWxH)

Ideal order suggestion for emission measurement on thermal processes

Part no.
testo 350 Control Unit 0632 3511
Option BLUETOOTH® wireless transmission
testo 350 Analyzer box 0632 3510
Option CO (H2-compensated) sensor, 0 to 10000
ppm, resolution 1 ppm
Option CO2 (NDIR) sensor, 0 to 50 Vol %, resolution
0.01 Vol %, infrared measurement principle, incl. abso-
lute pressure measurement, condensate container
filling level monitoring and CO2 absorbtion filter with fil-
ler pack
Option NO sensor, 0 to 4000 ppm, resolution 1 ppm
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Option Peltier gas preparation incl. hose pump
Option BLUETOOTH® wireless transmission

Gas sampling probe, modular, incl. special hose for 0600 8764
NO2-/SO2 measurement, cone, thermocouple NiCr-Ni
(TI), probe shaft length 335 mm, Tmax probe shaft
1000 °C, hose length 2.2 m
easyEmission software 0554 3334
100-240 V AC / 6.3 V DC international mains unit 0554 1096
Transport case for safe and tidy storage for flue gas 0516 3510
analyzer testo 350, gas sampling probe and accesso-
ries, dimensions 570 x 470 x 210 mm (LxWxH)
We measure it.
testo 350

testo 350 facilitates emission measurements ...

... thanks to a colour display with graphic menu


3 Step by step – Information in the display guides through the
measurement, meaning no previous familiarity with the instru-

05.05.10 09:06
ment is necessary
3 Specific fuels are pre-set for the application
3 Application-specific flue gas parameters are stored in the menu

Box 3
3 Instrument settings such as the dilution factor of gas sensors are
activated by application
In this measurement, very high CO con-
centrations can occur at short notice. In 3 Automatic testing of whether the relevant gas sensors are con-
order to protect the sensors, and to achie- nected to the intended dilution slot
ve a longer sensor life, please plug the
CO sensor into the dilution slot. The sen-
3 Special measurement mode for the testing of catalytic converters
sor may only be exchanged when the
with two flue gas analyzers
instrument is switched off! 3 Faster and easier analysis of the system status thanks to graphic
and coloured presentation of the measurement values – a glance
is enough!

... thanks to the instrument diagnosis


3 Information on the current status of the flue gas analyzer testo
Options OK 350 at any time
3 Early warning reports of approaching replacement of wearing
parts – to be on the safe side.
Example of display of the control unit
diagnosis function and information in clear text

Efficient emission measurements which are


also cost-effective in the long term:

• Easy exchange of the gas sensor by the user.


• After a warning report from the flue gas analyzer, wearing
parts can always be replaced in time.
• Probe shafts can be easily exchanged or replaced.
• Further gas measurement parameters can be added at any
time. Simply order additional gas sensors, install, and measu-
re safely.
• Thanks to the unique measuring range extension, measure-
ments can be carried out flexibly with only one gas sensor.
• The cross-sensitivity filter of the NO sensor can be exchan-
ged by the user after a report

Exchanging probe shaft

Replacing filter

8
We measure it.

easyEmission software – convenient measurement data management

Using the "easyEmission" software, data can be read out, conveniently processed, archived
and managed.

Advantages of easyEmission

3 Presentation of the measurement values as a table or a graph

3 User-defined measurement intervals(from one


measurement / second to one measurement / hour)

3 Online measurement via BLUETOOTH® wireless transfer or


by USB connection

3 Customer and application-specific measurement protocols

3 Data structure and measurement information are transferable


from the PC/notebook to the instrument

3 All instrument configurations and settings are easily


carried out with easyEmission

3 Direct export to Excel and PDF formats


sion
test ver m
ay o
3 Easy implementation of individual formulas for the user’s
30-d w.testo.c
own calculations w w
3 Calculation of fuel factors when using customer-specific fuels

3 Control of the bus system with up to 16 flue gas analyzer boxes

3 Implementation of individual cross-sensitivity adjustments of the gas sensors

An overview of the testo 350 data interfaces

It is this easy to control measurements, read


out, transfer and print measurement data! These
data interfaces are selectable for easy communi- Infrared interface

cation and data transfer: IR

Wireless transfer*

• Bluetooth®
2.0 (up to 100 m without obstruction)
• USB
• Infrared interface
(Communication with the Testo printer)
• Testo databus
(up to 800m cable length) for the simultane-
Testo databus
ous operation of up to 16 analyzer boxes.
Control optionally via PC, Testo databus con-
troller or control unit.

Testo databus
controller
Databus
connection cable

9
testo 350

Ordering data testo 350


testo 350 Control unit Part no. PC software and Testo databus
testo 350 Control Unit, displays measurement values and con- 0632 3511 Software “easyEmission”, incl. USB connection cable
0554 3334
trols analyzer box, incl. rech. battery, measurement data store, instrument-PC. Functions: user-definable measuring intervals,
USB interface and connection for Testo databus transfer of readings to Microsoft EXCEL within seconds, user-
definable fuels, representation of readings as table or graph,
testo 350 Option for control unit testo 350 simple production of customer-specific measurement protocols
Option BLUETOOTH® wireless transmission etc.

Software “easyEmission”, incl. Testo Databus Controller with 0554 3336


testo 350 Accessories for control unit testo 350 USB-connection cable instrument-PC, cable for Testo databus.
0554 1096 For example, if several Testo 350 flue gas analyzers are connec-
100-240 V AC / 6.3 V DC international mains unit ted to the Testo databus, they can be controlled and read out
via a PC (possible measurement interval in databus from 1 mea-
testo 350 analyzer box testo 350 Part no. surement per second)
0632 3510 Multiple software licence “easyEmission” for flue gas analyzer 0554 3337
testo 350 analyzer box, equipped with O2, incl. differential pres- testo 350
sure sensor, temperature probe input Type K NiCr-Ni and Type
S Pt10Rh-Pt, connection Testo databus, rech. battery, integra- Connection cable for Testo databus between Control Unit and 04490075
ted combustion air probe (NTC), trigger input, measurement analyzer box or between several analyzer boxes, with bayonet
data store, USB interface, updatable to max. 6 gas sensors fitting, length 2 m
selected from CO, COlow, NO, NOlow, NO2, SO2, CO2 NDIR, Connection cable for Testo databus between Control Unit and 0049 0076
analyzer box or between several analyzer boxes, with bayonet
A second gas sensor must be installed in testo 350-S, otherwise the instrument is unable fitting, length 5 m
to function. Up to 5 additional sensors can be fitted.
Connection cable for Testo databus between Control Unit and 00490077
Option CO (H2-compensated) sensor, 0 to 10000 ppm, resolution 1 ppm analyzer box or between several analyzer boxes, with bayonet
fitting, length 20 m
Option COlow (H2-compensated) sensor, 0 to 500 ppm, resolution 0.1 ppm
Other cable lengths up to 800 m on request
Option NO sensor, 0 to 4000 ppm, resolution 1 ppm
Analog ouput box set, 6 channels, 4 to 20mA, for transfer of 05543149
Option NOlow sensor, 0 to 300 ppm, resolution 0.1 ppm measurement values to e.g. analog recorder, set consists of
analog output box, connection cable Testo databus, length 2
m, Testo databus input impedance.
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Printers and accessories
Option SO2 sensor, 0 to 5000 ppm, resolution 1 ppm
Testo fast printer with wireless infrared interface, 1 roll of ther- 0554 0549
Option CO2 (NDIR) sensor, 0 to 50 Vol %, resolution 0.01 Vol %, infrared mal paper and 4 mignon batteries for printing readings out on
measurement principle, incl. absolute pressure measurement, condensate site
container filling level monitoring and CO2 absorption filter with filler pack.
For long-term measurements > 15 minutes measurement time, the Peltier Set BLUETOOTH® printer with wireless Bluetooth interface, 0554 0553
gas preparation is additionally recommended. incl. 1 roll of thermal paper, rech. battery and mains unit

Spare thermal paper for printer (6 rolls), permanent, measure- 0554 0568
Option CxHy sensor, methane 100 to 40000 ppm, propane 100 to 21000
ppm, butane 100 to 18000 ppm, resolution 10 ppm. Pellistor is adjusted to ment data documentation can be read for up to 10 years
methane ex-works 0554 0569
Spare thermal paper for printer (6 rolls)
Option H2S sensor, 0 to 300 ppm, resolution 0.1 ppm
Calibration certificates
Option BLUETOOTH® wireless transmission ISO calibration certificate flue gas, calibration points 2.5 Vol% O2 0554 0003
100 and 1000 ppm CO 800 ppm NO 80 ppm NO2 1000 ppm
Option Peltier gas preparation incl. peristaltic pump for automatic condensa- SO2
te evacuation
ISO calibration certificate flow velocity, hot wire/vane anemo- 0554 0004
Option fresh air valve for long-term measurement, incl. measuring range meter, Pitot tube; calibration points 1, 2, 5, 10 m/s
extension with dilution factor 5 for all sensors. For measurements >2 hours,
the option Peltier gas preparation is additionally recommended. ISO calibration certificate flow velocity, hot wire/vane anemo- 0554 0034
meter, Pitot tube; calibration points 5, 10, 15, 20 m/s
Option measuring range extension for individual slot with the following selec-
table dilution factors: 0, 2, 5, 10, 20, 40
Option DC voltage input 11V to 40V
Option special gas pump for long-term measurements with extended gua-
rantee. For measurements >2 hours, the option Peltier gas preparation is
additionally recommended.

Option automatic zeroing of pressure sensor for continuous flow velocity /


differential pressure measurement
Accessories testo 350 analyzer box and transport case Part no.
Cable with battery terminals and adapter for connection to DC
0554 1337
voltage input testo 350 analyzer box

Exchangeable filter NO sensor (1 off), blocks cross-gas SO2 0554 4150

Transport case for safe and tidy storage for flue gas analyzer 0516 3510
testo 350, gas sampling probe and accessories, dimensions
570 x 470 210 mm (LxWxH)
Carrying strap set for analyzer box testo 350
Carrying strap set for analyzer box testo 350 0554 0434

Spare dirt filter for analyzer box testo 350 (20 off) 0554 3381

Hose set to convey flue gas from analyzer box testo 350, 0554 0451
length 5m
Wall holder for flue gas analyzer testo 350, lockable 0554 0203

Current/voltage cable (0 to 1000 mV, 0 to 10 V, 0 to 20 mA) 0554 0007

10
We measure it.

Ordering data testo 350


Standard gas sampling probes Part no. Flue gas probes for industrial engines Part no.
Modular flue gas probes, available in Engine probes
2 lengths, incl. probe stop, NiCr-Ni
thermocouple, 2.2 m hose and parti- Ø 8 mm Ø 8 mm Ø 14 mm
cle filter
Gas sampling probe, modular, incl. special hose for NO2-/SO2 0600 9766 Flue gas probe for industrial engines, probe shaft length 335 mm, 0600 7550
measurement, cone, thermocouple NiCr-Ni (TI), probe shaft length incl. cone, heat protection shield, special hose for NO2-/SO2 mea-
335 mm, Tmax probe shaft 500°C, hose length 2.2 m surement, Tmax probe shaft 1000 °C, hose length 2.2 m

Gas sampling probe, modular, incl. special hose for NO2-/SO2 0600 8764 Flue gas probe with pre-filter for industrial engines, probe shaft length 0600 7551
measurement, cone, thermocouple NiCr-Ni (TI), probe shaft length 335 mm, incl. cone, heat protection shield, special hose for NO2-/SO2
335 mm, Tmax probe shaft 1000°C, hose length 2.2 m measurement, Tmax probe shaft 1000 °C, hose length 2.2 m

Gas sampling probe with pre-filter, modular, incl. special hose for 0600 8766 Flue gas probe accessories for industrial engines Part no.
NO2-/SO2 measurement, cone, thermocouple NiCr-Ni (TI), probe
Thermocouple for flue gas temperature measurement, NiCr-Ni, 0600 8894
shaft length 335 mm, Tmax probe shaft 1000°C, hose length 2.2
length 400 mm, Tmax. +1000 °C with 2.4 m connection cable
m, Ø pre-filter 14 mm
and additional temperature protection
Gas sampling probe, modular, incl. special hose for NO2-/SO2 0600 9767 0600 8895
Thermocouple for flue gas temperature measurement, NiCr-Ni,
measurement, cone, thermocouple NiCr-Ni (TI), probe shaft length length 400 mm, Tmax. +1000 °C with 5.2 m connection cable
700 mm, Tmax probe shaft 500°C, hose length 2.2 m and additional temperature protection
Gas sampling probe, modular, incl. special hose for NO2-/SO2 0600 8765 0554 7455
Spare probe shaft with pre-filter for flue gas probe for industrial
measurement, cone, thermocouple NiCr-Ni (TI), probe shaft length engines, probe shaft length 335 mm, Tmax probe shaft 1000°C
700 mm, Tmax probe shaft 1000°C, hose length 2.2 m
Temperature sensors Part no.
Gas sampling probe with pre-filter, modular, incl. special hose for 0600 8767
NO2-/SO2 measurement, cone, thermocouple NiCr-Ni (TI), probe Combustion air temperature probe, immersion depth 60 mm 0600 9797
shaft length 700 mm, Tmax probe shaft 1000°C, hose length 2.2 m,
Ø pre-filter 14 mm Pitot tubes Part no.
Accessories standard gas sampling probes Part no. 350 mm / 1000 mm Ø 7 mm
Hose extension, length 2.8 m
0554 1202
Pitot tube stainless steel, 350 mm long, for measurement of
Probe shaft with pre-filter, probe shaft length 335 mm, Tmax 0554 2145
0554 8766 flow velocity
probe shaft 1000°C, Ø pre-filter 14 mm
Pitot tube, 1000 mm long, stainless steel, measures flow velocity 0554 2345
Probe shaft with pre-filter, probe shaft length 700 mm, Tmax 0554 8767
probe shaft 1000°C, Ø pre-filter 14 mm
Connection hose, silicon, length 5 m, load to maximum
0554 0440
0554 3372 700 hPa (mbar)
Spare sintered filters (2)
Probe shaft, length 700 mm, Tmax probe shaft 500°C 0554 9767 Straight Pitot tube, stainless steel, length 350 mm for measuring
0653 2041
flow velocity, incl. temperature measurement, 3-fold hose (5 m
Probe shaft, length 335 mm, Tmax probe shaft 1000°C 0554 8764 length) and heat protection shield

Probe shaft, length 700 mm, Tmax probe shaft 1000°C 0554 8765 Straight Pitot tube, stainless steel, length 750 mm for measuring
0653 2042
flow velocity, incl. temperature measurement, 3-fold hose (5 m
0554 3385 length) and heat protection shield
Spare dirt filter for probe handle

Industrial gas sampling probes – modular system Part no.


Heated handle, voltage supply 115 to 230 V, 50/60Hz, temperature Power consumption: 200 watts; Temp. gas path: > 180 °C; Ready 0600 7920
gas path > 180 °C, IP54, gas input G1/4‘’, gas output M10x1 outer to operate: after approx. 20 min; Length of mains cable: 3 m; Pro-
thread tection class: IP54; Ambient temp.: -20 to +50 °C; gas inlet:
G1/4“; gas outlet: M 10x1 outer thread; weight: 1.7 kg
Adapter, unheated, IP54, gas input G1/4‘’, gas output M10x1 outer Ambient temp.: -20 to +50 °C; Protection class: IP54; Gas inlet: 0600 7911
thread G1/4“; Gas outlet: M 10x1 outer thread; Weight: 0.4 kg

Unheated sampling probes +600 °C, stainless steel 1.4571, length 1 m Connection: G1/4“ 0600 7801
1000 mm
Weight: 400 g
Ø 12 mm 0600 7803
Unheated sampling probe up to +1200 °C, Inconel 625, length 1 m Ø 20 mm
Connection: G1/4“
Unheated sampling probe up to +1800 °C, Al oxide, length 1 m 1000 mm
Weight: 400 g 0600 7805
Ø 12 mm
Ø 20 mm
Heating: > +180 °C; power consumption: 650 watts; Connec-
Heated sampling probe, voltage supply 230 V / 50 Hz, stainless steel tion: electr. connection to heated handle, connection adapter 0600 7820
1000 mm
1.4571, heating > 180°C, exhaust gas temperature max. +600 °C with thread connection/screw socket G1/4“; Max. flue gas
Ø 25 mm temp.: +600 °C
1000 mm 0600 7802
Extension shaft up to +600 °C, stainless steel 1.4571, length 1 m Connection: Thread screw/screw socket G1/4“; Weight:
Extension shaft up to +1200 °C, Inconel 625, length 1 m 0.45 kg
Ø 12 mm 0600 7804
Ø 20 mm
Pre-filter for dusty flue gases, ceramic, dust load max. 20g/m³, filter 50 mm Dust load: max. 20 g / m3; filter fineness: 20 µm; Temperature: 0554 0710
pore size 20µm, temperature max. 1000 °C max. 1000 °C; Material: ceramic; Connection: G1/4“ thread
nipple; Weight: 0.2 kg
Ø 23 mm
Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, 1.2 m long 0430 0065
Connection: To analyser via 4 m connection cable with 8 pin
plug; Weight: 0.15 kg.
Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, 2.2 m long The length depends on the number of sampling and extension 0430 0066
Ø 4 mm pipes used.

4m Hose material inside: PFFE hose with 2 mm inner diameter


Special sampling hose for accurate NO2-/SO2- measurements, length 4m (lowest absorption, self-cleaning effect); Material outside: rub- 0554 3384
ber; length: 4.0 m; Weight: 0.45 kg
Extension cable, length 5 m, between plug-in head cable and instrument 0554 0063

0554 0760
Mounting flange, stainless steel 1.4571, adjustable quick-action fit-
ting, suitable for all sampling7extension pipes 130 Ø 160 mm
mm

Transport case for industrial probes, aluminium profile, space for: handle, probes, flange and accessories, dimensions 1270 x 320 x 140 mm (LxWxH) 0516 7900

11
testo 350

Technical data Control Unit


Control-Unit testo 350 Analog output box (mA Out)
Country permits BLUETOOTH® wireless transmission for flue gas analyzers testo 350
The BLUETOOTH® wireless module used by Testo has permits for the following listed coun-
Oper. temp. -5 to +45 °C -5 to +45 °C tries, and can only be used in those countries, i. e. BLUETOOTH® wireless transfer may not
be used in any other country!
Storage temp. -20 to +50 °C -20 to +50 °C
Europe including all EU member states
Battery type Li-Ionen –
Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Battery life 5 hh (without wireless connection) – Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg,
Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden and Tur-
Memory 2 MB (250,000 measurement values) – key
European countries (EFTA)
Weight 440 g 305 g Iceland, Liechtenstein, Norway and Switzerland

Dimensions 88 x 38 x 220 mm 200 x 89 x 37 mm Non-European countries


Canada, USA, Japan, Ukraine, Australia, Colombia, El Salvador, Venezuela.
Warranty 2 years 3 years

Protection class IP 40 –

Technical data Analyzer box testo 350


O2 measurement COlow meas. (H2 COlow meas. (H2 NO measure- NOlow measure- NO measure-
2
SO2 measure- CO2 meas. (IR) H2S measure-
compensated)* compensated)* ment ment ment ment ment
Meas. range 0 to +25 Vol. % 0 to +10000 0 to +500 ppm 0 to +4000 ppm 0 to +300 ppm 0 to +500 ppm 0 to +5000 ppm 0 to +50 Vol. % 0 to +300 ppm
O2 ppm CO CO NO NO NO2 SO2 CO2 H2S
Accuracy ±0.8% of fsv (0 ±5% of mv (+200 ±5% of mv (+40 ±5% of mv (+100 ±5% of mv (+40 ±5% of mv (+100 ±5% of mv (+100 ±0.3 Vol. % CO2 ±5% of mv (+40
to +25 Vol. % O2) to +2000 ppm to +500 ppm to +1999.9 ppm to +300 ppm to +500 ppm to +2000 ppm + 1% of mv (0 to to +300 ppm)
CO) CO) NO) NO) NO2) SO2) 25 Vol. % CO2) ±2 ppm (0 to
±10% of mv ±2 ppm CO (0 to ±10% of mv ±2 ppm NO (0 to ±5 ppm NO2 (0 ±10% of mv ±0.5 Vol. % CO2 +39.9 ppm)
(+2001 to +39.9 ppm CO) (+2000 to +4000 +39.9 ppm NO) to +99.9 ppm (+2001 to +5000 + 1.5% of mv
+10000 ppm ppm NO) NO2) ppm SO2) (>25 to 50 Vol. %
CO) ±5 ppm NO (0 to ±5 ppm SO2 (0 CO2)
±10 ppm CO (0 +99 ppm NO) to +99 ppm SO2)
to +199 ppm
CO)
Resolution 0.01 Vol. % O2 (0 1 ppm CO (0 to 0.1 ppm CO (0 1 ppm NO (0 to 0.1 ppm NO (0 0.1 ppm NO2 (0 1 ppm SO2 (0 to 0.01 Vol. % CO2 0.1 ppm (0 to
to +25 Vol. % O2) +10000 ppm to +500 ppm +3000 ppm NO) to +300 ppm to +500 ppm +5000 ppm SO2) (0 to 25 Vol. % +300 ppm)
CO) CO) NO) NO2) CO2)
0.1 Vol. % CO2
(>25 Vol. % CO2)
Reaction time 20 s 40 s 40 s 30 s 30 s 40 s 30 s Æ10 s 35 s
Reaction type t95 t90 t90 t90 t90 t90 t90 t90 t90

* H2 display only as an indicator

Individual dilution with selectable dilution factor (x2, x5, x10, x20, x40)
CO (H2 compen- COlow meas. (H2 NO measure- NOlow measu- SO2 measure- CxHy measurement
sated) compensated) ment rement ment
Meas. range dilution factor- dilution factor- dilution factor- dilution factor- dilution factor- Methane: 100 to 40,000 ppm
dependent dependent dependent dependent dependent Propane: 100 to 21,000 ppm
Butane: 100 to 18,000 ppm
Accuracy ±2 % of m.v. ±2 % of m.v. ±2 % of m.v. ±2 % of m.v. ±2 % of m.v. ±2 % of m.v.
(additional error) (additional error) (additional error) (additional error) (additional error) (additional error)

Resolution 1 ppm 0.1 ppm 1 ppm 0.1 ppm 1 ppm 10 ppm

Dilution of all sensors (Factor 5)


When dilution of all sensors is activated, the measurement values of O2, CO2-(IR) and CxHy are not shown in the display.

CO (H2 compen- COlow meas. (H2 NO measure- NOlow measure- SO2 measure- NO2 measure- H2S measure-
sated) compensated) ment ment ment ment ment
Meas. range 2500 to 50000 500 to 2500 ppm 1500 to 20000 300 to 1500 ppm 500 to 25000 500 to 2500 ppm 200 to 1500 ppm
ppm ppm ppm
Accuracy ±5 % of m.v. ±5 % of m.v. ±5 % of m.v. ±5 % of m.v. ±5 % of m.v. ±5 % of m.v. ±5 % of m.v.
(additional error) (additional error) (additional error) (additional error) (additional error) (additional error) (additional error)
Pressure range Pressure range Pressure range Pressure range Pressure range Pressure range Pressure range
-100 to 0 mbar -100 to 0 mbar -100 to 0 mbar -100 to 0 mbar -100 to 0 mbar -100 to 0 mbar -100 to 0 mbar
at probe tip at probe tip at probe tip at probe tip at probe tip at probe tip at probe tip

Resolution 1 ppm 0.1 ppm 1 ppm 0.1 ppm 1 ppm 0.1 ppm 0.1 ppm

12
We measure it.

Technical data Analyzer box testo 350


Degree of Exhaust gas loss CO2 calculation Differential Differential Flow velocity Absolute pressurek (opt. Flue gas dewpoint cal-
effectivity pressure 1 pressure 2 if IR sensor equipped) culation
Meas. range 0 to +120 % -20 to +99.9 % qA 0 to CO2 max Vol. -40 to +40 hPa -200 to +200 hPa 0 to +40 m/s -600 to +1150 hPa 0 to +99.9 °Ctd
% CO2
Accuracy Calculated from O2 ±1.5% of m.v. ±1.5% of m.v. ± 10 hPa
±0.2 Vol. % (-40 to -3 hPa) (-200 to -50 hPa)
±1.5% of m.v. ±1.5% of m.v.
(+3 to +40 hPa) (+50 to +200 hPa)
±0.03 hPa ±0.5 hPa
(-2.99 to +2.99 hPa) (-49.9 to +49.9 hPa)
Resolution 0.1 % (0 to +120 0.1 % qA (-20 to 0.01 Vol. % CO2 0.01 hPa (-40 to 0.1 hPa (-200 to 0.1 m/s (0 to +40 1 hPa 0.1 °Ctd (0 to +99.9
%) +99.9 % qA) +40 hPa) +200 hPa) m/s) °Ctd)
Reaction time 40 s
Reaction type t90

Probe type Type K (NiCr-Ni) Type S (Pt10Rh-Pt) Ambient temperature


probe (NTC)
Meas. range -200 to +1370 °C 0 to +1760 °C -20 to +50 °C

Accuracy ±0.4 °C (-100 to +200 °C) ±1 °C (0 to +1760 °C) ±0.2 °C (-10 to +50 °C)
± 1 Digit ±1 °C (-200 to +100.1 °C)
±1 °C (+200.1 to +1370 °C)

Resolution 0.1 °C (-200 to +1370 °C) 0.1 °C (0 to +1760 °C) 0.1 °C (-20 to +50 °C)

Technical data CxHy sensor


Measurement Methane Propane Butane
parameter
Meas. range 1 100 to 40,000 ppm 100 to 21,000 ppm 100 to 18,000 ppm
Accuracy < 400 ppm (100 to 4000 ppm) < 400 ppm (100 to 4000 ppm) < 400 ppm (100 to 4000 ppm)
< 10 % of m.v. (> 4000 ppm) < 10 % of m.v. (> 4000 ppm < 10 % of m.v. (> 4000 ppm
Resolution 10 ppm 10 ppm 10 ppm
Min. O2 requirement 2% + (2 x m.v. methane) 2% + (5 x m.v. propane) 2% + (6.5 x m.v. butane)
in flue gas
Respopnse time t90 < 40 sec. < 40 sec. < 40 sec.
Response-Faktor ² 1 1.5 2
¹ Lower explosion limit must be adhered to.
² The HC sensor is adjusted to methane in the factory. It can be adjusted to another gas (propane or butane) by the user.

Other technical data


Dimensions: 330 x 128 x 438 mm Max. humidity load: +70 °C Dewpoint temperature at measurement gas
Weight: 4800 g input of analyzer box
Storage temperature: -20 to +50 °C Trigger input: Voltage 5 to 12 Volt
Operating temperature: -5 to +45 °C (risin g or falling flank)
Housing material: ABS Impulse width > 1 sec
Memory: 250,000 Measurement values Load: 5 V/max, 5 mA, 12 V/max. 40 mA
Power supply: AC mains unit 100V to 240V (50 to 60 Hz) Warranty:* Measuring instrument 2 years (apart from wearing parts,
DC voltage supply: 11V to 40V e.g. gas sensors...);
Max. dust load: 20 g/m³ dust in flue ags Gas sensors: CO/NO/NO2/SO2/H2S/CXHY: 1 year;
Dewpoint calculation: 0 to 99 °C td O2 sensor: 1 1/2 years;
Max. pos. pressure flue gas: max. +50 mbar CO2-IR sensor: 2 years.
Max. neg. pressure: min. -300 mbar Rech. battery 1 year
Pump through-put: 1 l/min. with through-put monitoring Protection class: IP40
Hose length: max 16.2 m (corresp. to 5 probe hose extensions) Battery life: Maximum load approx. 2.5 h
*Warranty applies for average sensor load.

13