Вы находитесь на странице: 1из 12

Heat Recovery Units

Heat Recovery Units


VENTAS Isıtma, Soğutma, Enerji Sistemleri, İnşaat VENTAS brand’s main principles are to serve its
Sanayi ve Ticaret Anonim Şirketi; has been customers as a high quality solution partner and to
established in 2011 for production, consulting, provide excellent service with a dynamic structure
project preparation and equipment supply in both in pre-sales and after-sales.
heating, cooling, air-conditioning and energy
efficiency areas. VENTAS, which is established on Having reached a fast and continuous growth track
top of twenty years of know-how and experience of since it has been established, VENTAS has
its founders in the aforementioned sectors, is managed to become a well-known company in
serving at its Istanbul Hadimkoy and Catalca heating, cooling, air-conditioning and energy
production centres. efficiency sectors throughout the country. Moreover,
the Turkish brand VENTAS has penetrated its
The product portfolio of HVAC market’s new brand excellent and high quality products into
VENTAS includes hygienic air handling units, international markets in a very short time frame,
comfort air handling units, high-efficiency and offered a complete product supply chain to
heat-recovery ventilation units, fan coil units, these markets through its wide dealer and service
exhaust fans with cabinet, supply fans with structure.
cabinet, duct type fans, roof type fans, fire smoke
removal fans, trench heaters, roof top package air Paying the utmost attention in its products to
conditioning systems (water cooled, air cooled, energy efficiency, endurance, reliability, sustainable
gas-fired, heat recovery etc.) units. technology and competitive price policy, VENTAS
offers to be the corporate solution partner of all
ISO 9001, CE, TSEK, GOST-R and EN 1886 investors and mechanical construction companies
certificates and benefiting all advantages of in Turkey and all over the world, and shares its
modern high technology, in VENTAS production dynamic vision, renewed and developed
centres, high quality and durable products are continuously, with all its customers.
manufactured by a dynamic and experienced
expert team with a meticulous and neat
workmanship, and a solution oriented approach.

EN 1886

2
www.ventas.com.tr

Technical Specifications

What is a heat recovery unit? Features and usage advantages of VENTASTAR


In today's technology, heat recovery air-conditioning units heat recovery air conditioning unit:
are mechanical air conditioning units designed to
produce high quality internal air in closed volumes while • Provides ease of operation and maintenance due to
providing energy saving. compact and slim design.
• Provides high quality indoor air with G4-class synthetic
Advantages fiber.
These units work with the principle of adding energy • Enables excellent heat and sound insulation
within the air exhausted from the environment to the with specially insulated internal surface.
• In radial-fan types, it offers 3-stage operating
fresh air given to the environment by using internal
capacity with direct coupled fans or proportional
air-to-air heat recovery plate exchangers. Thus, they
operating capacity.
allow for having high amount of energy savings.
• In plug-fan types, it offers proportional
(no stage) operating capacity with direct coupled fans.
Today, heat recovery air-conditioning units are used in • With its specially designed electronic card control,
summer, winter and mid-seasons, through 12 months of fresh air supply and exhaust fans can be driven
the year, to meet the fresh air demand required to independently, hence, VENTASTAR heat recovery
enhance the internal air quality within closed volumes air-conditioning unit can provide positive or negative
while saving from energy costs. pressure operation in concerned volume.
• It has quality-safety certificates: CE, TSEK, ISO 9001
Especially in industrial and commercial air-conditioning and GOST-R.
applications, they provide important conveniences and • It provides heat recovery with high efficiency and
wide range of deployment options. They contribute a lot capacity by using cross-flow aluminium plate heat
to the business economics via highly efficient heat exchangers with high thermal conductivity and
exchangers having high heat transfer capacities. performance.
• With its specially designed electronic card, it
allows to be connected to building automation system
In terms of deployment areas, they address multi
(BMS).
functional buildings. For instance; they can address
• Possibility of adding internal air quality sensor
residence applications, office buildings, financial centres,
and external air sensor.
chain stores, supermarkets, hospitals, shopping malls,
• In all standard models, it is possible to be delivered
schools, sport halls and restaurants. from readily available stocks. In case of need,
optionally out-of-standard production can be made for
different capacities and working principles.

Fresh Air Supply INDOORS

Exhaust Return

Duct Type Electric


Heater
Fan

Exhaust throw Fresh Air


Supply Control Panel

OUTDOORS SURROUNDING

Power Supply
Fresh air Exhaust Return

Exhaust throw

OUTDOORS
Filter
Fan

Fresh Air Intake


Filter

Junction Box

3
Heat Recovery Units

VENTASTAR VHRV-PL Plug-Fan Models

Unit Components 4
5
1 Fresh air fan 2
7
22 Heat recovery exchanger
33 Exhaust fan 3 8
44 Service gate for fresh air filter 1
55 Fresh air filter
6
66 Exhaust air filter
9
77 Electronic card
88 Service gate for exhaust fan/filter
99 Duct connection groove
1
10 Service gate for fresh air fan and filter 10

• High efficiency plug-fan technology • Wide Capacity Range


• Supplies fresh air to provide the indoor air quality • Ergonomic size
• Provides energy savings with a high efficiency aluminium exchanger • Easy installation and maintenance
• Provides G4 class filtering in both fresh air and exhaust sides. • Duct type cooler hydrous coil 7/12 °C
• Low noise level • Duct type cooler DX coil R410A
• Continuous speed control • Standard electronic control panel (BASIC/PRO Model)

VENTASTAR Plug Fan VHRV Models VHRV PL500 VHRV PL750 VHRV PL1000 VHRV PL1500 VHRV PL2000 VHRV PL3000 VHRV PL4000
Air Flow (m /h)
3
500 750 1000 1500 2000 3000 4000
External Static Pressure (Pa) 130 120 120 140 200 110 110
Heat Recovery Efficiency Value (%) Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator

Power Supply 230 Volt / 50 Hz / 1


Input Power (Watt) 2 x 102 2 x 155 2 x 210 2 x 225 2 x 515 2 x 480 2 x 680
Input Current (Ampere) 2 x 0,45 2 x 0,68 2 x 0,93 2 x 1,0 2 x 2,25 2 x 2,4 2 x 3,0
Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air

Optional Accessory Duct Type 1,5 2 3 4,5 6 9,0 12


Electrical Heater (kW) Q200 Q200 Q250 Q300 Q300 Q355 Q400
Optional Accessory
3,1 3,8 4,5 6,7 9,0 13,5 18,0
Duct Type Heater Hydrous Coil 90 / 70° (kW)
Optional Duct Type Cooler DX Coil
3,5 - 7 3,5 - 7 7 - 14 7 - 14 14 - 22,4 14 - 22,4 28 - 44,8
Capacities-R410A (kW)
Length (mm) 850 850 980 1350 1350 1700 1800
Width (mm) 665 665 700 980 980 1180 1180
Height (mm) 310 310 340 420 420 540 640
Duct Connection Diameter (mm) Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400
Weight (kg) 73 79 87 115 120 193 225
Service Space (mm) 330 330 350 490 490 590 900
Noise Level db(A) 42 43 43 45 48 52 55

* In our VENTASTAR PLUG-FAN PRO series, fans are continuously controlled proportionally.

4
www.ventas.com.tr

VENTASTAR VHRV-RD Radial-Fan Models

Unit Components
4 5

1 Fresh air fan 2 7


22 Heat recovery exchanger
33 Exhaust fan
3 1
44 Service gate for fresh air filter
55 Fresh air filter
66 Exhaust air filter
77 Electronic card 6 9
88 Service gate for exhaust fan/filter
99 Duct connection groove
10 Service gate for fresh air fan 8
10

• High efficiency radial-fan technology • Wide Capacity Range


• Supplies fresh air to provide the indoor air quality • 3 stage speed control
• Provides energy savings with a high efficiency aluminium exchanger • Ergonomic size
• Provides G4 class filtering in both fresh air and exhaust sides. • Easy installation and maintenance
• Low noise level • Standard electronic control panel (BASIC/PRO Model)

VENTASTAR Radial Fan VHRV Models VHRV RD2000 VHRV RD2500 VHRV RD3000 VHRV RD4000 VHRV RD5000 VHRV RD6000 VHRV RD8000
Air Flow (m /h)
3
2000 2500 3000 4000 5000 6000 8000
External Static Pressure (Pa) 200 150 220 220 220 180 120
Heat Recovery Efficiency Value (%) Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator

Power Supply 230 Volt / 50 Hz / 1-


Input Power (Watt) 2 x 450 2 x 450 2 x 550 2 x 750 4 x 750 4 x 750 4 x 750
Input Current (Ampere) 2 x 5,0 2 x 5,0 2 x 5,0 2 x 7,5 4 x 7,5 4 x 7,5 4 x 7,5
Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air

Optional Accessory Duct Type 6,0 9,0 9,0 12,0 18 24 24


Electrical Heater (kW) Q300 Q355 Q355 Q400 Q400 Q400 Q400
Optional Accessory
9,0 13,5 13,5 18,0 24 36 48
Duct Type Heater Hydrous Coil 90 / 70° (kW)
Optional Duct Type Cooler DX Coil
14 - 22,4 14 - 22,4 14 - 22,4 28 - 44,8 28 - 56 28 - 56 28 - 56
Capacities-R410A (kW)
Length (mm) 1500 1700 1700 1800 1900 2750 2750
Width (mm) 980 1180 1180 1180 2020 2055 2055
Height (mm) 420 540 540 540 540 540 540
Duct Connection Diameter (mm) Ø300 Ø355 Ø355 Ø400 395x740 395x755 395x755
Weight (kg) 125 140 190 225 240 280 280
Service Space (mm) 700 800 800 900 1010 1030 1030
Noise Level db(A) 48 49 52 55 56 58 58

* In VENTASTAR Radial-Fan series, fans are controlled in 3-stage speed.

5
Heat Recovery Units

VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Plug-Fan)

Unit Components
3
Fresh air 2 8 7 Exhaust
1 Recuperator intake return

22 Fresh Air Filter 4 5 6


33 Exhaust Filter 1
44 Heater Coil
55 Cooler Coil Exhaust Fresh air
throw supply
66 Drift Eliminator
77 Exhaust Fan
10
88 Fresh Air Fan 9
99 Power Panel
10 Stainless Steel Drain Pan Radial and Plug-Fan Models

VENTASTAR VHRV PLUS Models With Heater


VHRV PL500 VHRV PL750 VHRV PL1000 VHRV PL1500 VHRV PL2000 VHRV PL3000 VHRV PL4000
Coil and Cooler Coil (Plug-Fan)
Air Flow (m3/h) 500 750 1000 1500 2000 3000 4000
External Static Pressure (Pa) 90 80 80 80 125 60 60
Heat Recovery Efficiency Value (%) Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator

Power Supply 230 Volt / 50 Hz / 1


Input Power (Watt) 2 x 102 2 x 155 2 x 210 2 x 225 2 x 515 2 x 480 2 x 680
Input Current (Ampere) 2 x 0,45 2 x 0,68 2 x 0,93 2 x 1,0 2 x 2,25 2 x 2,4 2 x 3,0
Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air

Optional Accessory 1,5 2 3 4,5 6 9 12


Duct Type Electrical Heater (kW) Q200 Q200 Q250 Q300 Q300 Q355 Q400
Duct Type Heater Hydrous
3,1 3,8 4,5 6,7 9 13.5 18
Coil Capacities (kW)
Duct Type Cooler Hydrous Coil
3,5 5,5 7,5 11 15 22 30
Capacities (kW)
Duct Type Cooler DX Coil
3,5 - 7 3,5 - 7 7 - 14 7 - 14 14 - 22,4 14 - 22,4 28 - 44,8
Capacities-R410A (kW)
Length (mm) 1630 1630 1760 2180 2180 2580 2680
Width (mm) 820 920 990 1230 1330 1530 1630
Height (mm) 310 310 340 420 420 540 640
Duct Connection Diameter (mm) Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400
Weight (kg) 73 79 87 115 120 193 225
Service Space (mm) 410 460 490 620 660 760 810
Noise Level db(A) 42 43 43 45 48 52 55

6
www.ventas.com.tr

VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Radial Fan)

• High efficiency radial fan and plug-fan technology


• Supplies fresh air to provide the indoor air quality
• Provides energy savings with a high efficiency aluminium exchanger
• Provides G4 class filtering in both fresh air and exhaust sides.
• Low noise level
• Proportional or 3 stage speed control
• Possibility to work like a fresh air unit with its heater and cooler coils
• Provides heating and cooling capacity support
• Electronic card that can perform proportional capacity control and operating mod selection, which works fully
compatible with DX external unit
• Easy installation and maintenance

VENTASTAR VHRV PLUS Models With Heater


VHRV RD2000 VHRV RD2500 VHRV RD3000 VHRV RD4000 VHRV RD5000 VHRV RD6000 VHRV RD8000
Coil and Cooler Coil (Radial Fan)
Air Flow (m3/h) 2000 2500 3000 4000 5000 6000 8000
External Static Pressure (Pa) 120 100 220 160 140 90 100
Heat Recovery Efficiency Value (%) Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator

Power Supply 230 Volt / 50 Hz / 1


Input Power (Watt) 2 x 450 2 x 450 2 x 550 2 x 750 4 x 750 4 x 750 4 x 750
Input Current (Ampere) 2 x 5,0 2 x 5,0 2 x 5,0 2 x 7,5 4 x 7,5 4 x 7,5 4 x 7,5
Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air

Optional Accessory 6 9 9 12 18 24 24
Duct Type Electrical Heater (kW) Q300 Q355 Q355 Q400 Q400 Q400 Q400
Duct Type Heater Hydrous
9 13.5 13.5 18 24 36 48
Coil Capacities (kW)
Duct Type Cooler Hydrous Coil
15 18 22 30 35 40 48
Capacities (kW)
Duct Type Cooler DX Coil
14 - 22,4 14 - 22,4 14 - 22,4 28 - 44,8 28 - 56 28 - 56 28 - 56
Capacities-R410A (kW)
Length (mm) 2330 2580 2580 2680 2780 3630 3680
Width (mm) 1330 1530 1530 1650 2420 2755 3055
Height (mm) 420 540 540 540 540 540 540
Duct Connection Diameter (mm) Ø300 Ø355 Ø355 Ø400 395x740 395x795 395x795
Weight (kg) 125 140 190 225 240 280 280
Service Space (mm) 700 800 800 900 1010 1030 1030
Noise Level db(A) 48 49 52 55 56 58 58

7
Heat Recovery Units

VENTASTAR VHRV VT Vertical Type Application Model Diameters

A C

D B
E E

VENTASTAR VHRV Width (mm) Height (mm) Depth (mm) Height with legs (mm) Duct Connection Diameter
Vertical Type VT Model A B C D (mm) E
VHRV VT PL500 665 950 310 1030 200

VHRV VT PL750 665 950 310 1030 200

VHRV VT PL1000 700 1080 340 1160 250

VHRV VT PL1500 980 1450 420 1530 300

VHRV VT PL2000 980 1450 420 1530 300

VHRV VT RD2000 980 1600 420 1680 300

VHRV VT RD3000 1205 2105 550 2185 400

VHRV VT RD4000 1205 2105 550 2185 400

VHRV VT RD5000 2020 2000 550 2080 395x740

VHRV VT RD6000 2055 2850 550 2930 395x755

VHRV VT RD8000 2055 2850 550 2930 395x755

*Vertical type designed version of our standard heat recovery unit models. It has all technical specifications that standard heat recovery unit models have. Duct connections
are designed as rectangular for VHRV VT 5000, 6000 and 8000 models.

8
www.ventas.com.tr

VENTASTAR Heat Recovery Air Conditioning Units Electronic Board Features

VENTASTAR heat recovery air conditioning units are controlled Wired room control device has the functions to turn the unit on
with a standard electronic board and a wired room control device. and off, to control fresh air and exhaust fans separately as
proportional or 3 stage speeds according to fan type (plug or
Ventastar heat recovery air conditioning units have 2 different radial), to optionally connect to duct type electrical heater or
control options according to their functional features. These duct type hydrous coil staged control functions, and to connect
options are presented as VENTASTAR BASIC and VENTASTAR to central automation system (BMS) or VRV/VRF system. It can
PRO models. also display status and error information just like an air
handling unit automation.

VENTASTAR BASIC Control Card VENTASTAR PRO Control Card Indoor Thermostat

FUNCTIONAL FEATURES VENTASTAR BASIC VENTASTAR PRO


ROOM CONTROL PANEL
Room control panel (wired) Standard Standard
Room temperature sensor Standard Standard
Touch keypad Standard Standard
Ability to communicate with electronic power board Standard Standard
Visual warning and error notification Standard Standard
Advanced user and service menu Standard Standard
Remote control panel (wireless) Optional Optional
Central control panel Optional Optional
ELECTRONIC CARD (POWER UNIT)
Fresh air fan control continuous (proportional) Standard Standard
Exhaust air fan control continuous (proportional) Standard Standard
Ability to drive fans independently Standard Standard
220 V AC supply Standard Standard
High voltage protection Standard Standard
Air quality sensor connectivity - Standard
Blow air temperature sensor connectivity Standard Standard
External air sensor connectivity Standard Standard
Humidity sensor connectivity Standard Standard
Filter contamination sensor connectivity - Standard
Fan rotation detection possibility Standard Standard
Cooler coil control (proportional) Standard Standard
Heater coil control (proportional) Standard Standard
Damper motor control - Standard
Alarm and warning outputs Standard Standard
BMS MODBUS connectivity Standard Standard
EMI-RFI filter possibility Standard Standard
Hour-Date weekly program possibility Standard Standard
Summer-Winter program possibility Standard Standard
Humidification and dehumidification control possibility (0-10 Volts) Standard Standard
Inverter control device EC motor control possibility (0-10 Volts) - Standard

9
Heat Recovery Units

Optional Accessories

Duct Type Silencers


VENTAS duct type silencers are produced in two different models: VDS model for circular duct system
and VDKS model for rectangular duct system. Production of all silencers are performed according to
international standards, sizes, coulisse numbers. Circular silencers are produced in standard circular
duct sections, whereas rectangular duct type silencers can be produced according to the required
sizes of the project. All models are appropriate for fast and easy assembly to the existing duct system
with minimum air leakage. For sound isolation, glass wool is used as our standard production and
optionally rock wool can be used.

Duct Type Electric Heater


VENTASTAR KTE duct type electric heaters are produced according to EMC
89/336/EEC directives, as per EN 55014-1, EN 61000-3-2/3-3 standards with EMC tests done. They are
produced in standard circular duct section sizes as monophase and triphase. Duct type electric
heaters have two emergency thermostats for excessive-temperature cut out. VENTASTAR heat
recovery air conditioning units can be controlled automatically with an electronic card or manually on
the device.

Duct Type Heater Or Cooler Hydrous Coil


VENTASTAR KSB duct type hydrous coil are produced both in rectangular and circularduct sections
in standard capacities, whereas different project based capacities can be produced upon request.
Duct type hydrous coil units are designed in order to be deployed easily in suspended ceiling, to be
directly applied into the blowing entrances of heat-recovery units and to provide easy installation and
maintenance.

External Air Bypass Connection Kit


Heat-recovery air conditioning units provides energy saving by means of the heat transfer between the warm and cold phases of plate
exchanger. Especially in mid-seasons (spring and autumn) or in morning and evening hours, the external air temperature gets closer to the
internal ambient temperature. In order to use the fresh air more efficiently (in order to remove the exchanger pressure fail), the plate
exchanger can be bypassed. Besides, in warm mid seasons, if the external air temperature reduces below the internal air temperature, the
plate exchanger is bypassed in order to benefit from this air to cool indoor air. With the by-pass kit, external air temperature is controlled by
the electronic card automatically , and the external air is blown inside bypassing the plate exchanger when needed.

By-pass

By-pass Damper
Filter

Exhaust Return Fresh air supply

Fresh air
Exhaust Return
intake
External Air
Sensor

Damper

10
www.ventas.com.tr

11
Ventas Isıtma, Soğutma, Enerji Sistemleri, İnşaat San. ve Tic. A.Ş.

Ventas Headquarters Ventas Hadımköy Facility Ventas Catalca Facility


Ortaklar Cd. Denizhan Sk. Lale Han No:7 Kat:2 Alkop Alüminyumcular Sanayi Sitesi C1 Blok Çakıl Mh. Elbasan Cd. No: 126/A 34540
Mecidiyeköy Şişli, İstanbul, Turkey No:1-2-3-4-5, 34500 Esenyurt, İstanbul, Turkey Çatalca, İstanbul, Turkey
T: +90 212 216 05 16 • F: +90 212 216 05 14 T: +90 212 858 12 82 • F: +90 212 858 12 79 T: +90 212 858 12 82 • F: +90 212 858 12 79

Ankara Regional Office: Aziziye Mahallesi Kırkpınar Sokak No: 10/5 Çankaya, Ankara, Turkey • T: 0312 439 59 50 • F: 0312 439 59 50
Bursa Regional Office: Alaaddinbey Mh. Pazar Cd. No:27 A/C Nilüfer, Bursa, Turkey • T: +90 224 441 03 66 • F: +90 224 441 03 67
Diyarbakır Regional Office: Kayapınar Mah. Gap Bulvarı Peyas 1 Sok. No:1 A Blok Kayapınar, Diyarbakır, Turkey • T: +90 412 251 51 45 • F: +90 412 251 51 45
Konya Regional Office: Fevzi Çakmak Mahallesi 10670 Sokak 27/B Karatay, Konya, Turkey • T: +90 332 236 22 64 • F: +90 332 236 73 56

www.ventas.com.tr
2016/VEB/1