Data Sheet

Cerberus PRO
LED Annunciator Driver
Model FT2007-U1
ARCHITECT AND ENGINEER SPECIFICATIONS
• Provides 96 light-emitting diode (LED) outputs for up
to 32 zones – including separate Alarm, Supervisory
and Trouble outputs per zone

• Contains 16 programmable inputs, plus one (1) key switch


 Key switch is positioned from the 17th input at all times

• Displays seven (7) system-status LEDs:


 Power ON; Trouble, Ground Fault, Audibles ON;
Acknowledge; Silence, and Reset
 The first LED is always Power ON FT2007-U1
(Both cards)
• Supervised via a RS–485 communication bus
 Maximum eight (8) modules allowed on each RS–485 interface
• Requires external 24 Volts, DC
• UL 864 9th Edition Listed;
• Set address and Baud Rate via programmable DIP switches FM (#3010) Approved

Product Overview Specifications – (continued)


The LED Annunciator Driver, Model FT2007-U1, Each annunciator driver is operated as a remote
from Siemens – Fire Safety is the main graphics display indicator at a distance of up to 3,281 ft.
component for custom graphic annunciators on (1,000m) from a Cerberus PRO FACP.
addressable Cerberus PRO panels. This optional Model FT2007-U1 gets its operating power from either
system module provides outputs for system the auxiliary power connection from a Cerberus PRO
status as well as zone status. Model FT2007-U1 addressable control panel, Model FC901, or from a
is supervised via a built-in RS−485 interface. A separate UL Listed, 24VDC power supply.
maximum eight (8) modules are allowed on
Each shipment of the LED Annunciator Driver includes
each RS−485 communication bus.
two (2) PC boards [PCBs]; one (1) built-in RS−485
interface, and one (1) LED driver. Additionally, one (1)
Specifications ribbon cable is packaged, allowing connectivity
Model FT20007-U1 is designed for use in between the two (2) PCBs.
custom graphic annunciators. Notes: A system enclosure or display panel must be ordered
separately. The user also needs to provide the cable
There are 16 inputs to accommodate user- between the Molex connector and the system-
defined system commands, which include: display LEDs / switches.
Reset; Silence/Unsilence; Acknowledge, and
Lamp Test. Inputs can also be programmed as Temperature and Humidity Range
``Generic’’, which allows additional flexibility for Model FT2007-U1 is UL Listed for indoor dry locations
customized functionality. within a temperature range of 120 +/- 3°F (49 +/- 2°C) to
Model FT2007-U1 also includes 96 highly 32 +/- 3°F (0 +/- 2°C) and a relative humidity of 93 +/- 2%
programmable outputs to drive LED indicators. at a temperature of 90 +/- 3°F (32 +/- 2°C).

Cerberus PRO 9824


Fire Safety Products LED Annunciator Driver
Technical Data – Special Note for Applications in Canada –
Driver The Model FT2007-U1 LED Annunciator
Operating Voltage: 16 ─ 30 VDC Driver is used optionally in the provinces,
(at 24VDC, nominal)
Supply and can only be utilized to display system
Inputs Activation Current: 250mA status in real time.
Operating Current:
(quiescent)
25mA In order to comply with ULC regulations,
each LED Annunciator Driver must be housed
 Design
in a lockable ULC-S527 Listed enclosure.
14 ─ 18, 28 AWG
RS-485:  Admissible
[American Wire Gauge]
Connections cross-section
cable Details for Ordering
Inputs and Plug-in connection via four Model
Part
Description
Outputs (4) ribbon cables Number
(not included)
Operating LED Annunciator Driver
Indoor / dry Shipment includes:
Location:
Operating 0° – 120°F – One (1) ribbon cable
General Temperature: (0° – 49°C) (for connection between
Properties Storage 0° – 140°F PCBs)
Temperature: (0° – 60°C) – One (1) end-of-line (EOL)
FT2007-U1 termination jumper
Humidity: ≤95 %, relative S54400-A142-A1 – Three (3) plastic
4.5” + {4.3”} -x- 6.0” -x- 1.2” cable ties
Dimensions: – Four (4) connectors for
Physical { W-x-H-x-D } (11.4 cm. + {11.0 cm.} -x-
15.2 cm. -x- 3.0 cm.) customer-provided interface
Properties (additional ribbon cables not
Weight: 1 Lb. (454g) included)
– Ten (10) hexagonal standoffs
Related Documentation with mounting screws

Data Sheet Number


Cerberus PRO 50-point addressable FACP 9813
Cerberus PRO 252-point | 504-point
9815
addressable FACP
Cerberus PRO 252-point | 504-point
9815C
addressable FACP (for Canada)
Cerberus PRO Intelligent
9821
Voice Communication (IVC)

NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is
s Cerberus PRO subject to change without notice. The devices described here have specific instruction
sheets that cover various technical, limitation and liability information.
Siemens Industry, Inc. ─ Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations
document, which also contains important information, are provided with the product and,
8 Fernwood Road • Florham Park, NJ 07932 are available from the Manufacturer.
Tel: (973) 593-2600 • Fax: (908) 547-6877 Information contained in these documents should be consulted before specifying or
Web: www.USA.Siemens.com/Cerberus-PRO using the product. For further information or assistance concerning particular problems
contact the Manufacturer.

April 2017 ─ Supersedes issue dated 2/2016


Building Technologies Division (Rev. 2)
SII ─ Fire Safety
[Printed in U.S.A ]