January 8, 2009
To: J. D. Davis
All thirty samples met API 5L 43rd Edition Grade X70 transverse pipe body
tensile test requirements.
Sample Identification
Samples were transmitted to An-Tech with the custody transfer documents.
The samples were submitted marked with the heat number and pipe number,
as shown in Figures 1 and 2. Each sample was assigned an individual An-
Tech Laboratories job number, beginning with 08-3468 and continuing
sequentially to 08-3497.
Page 1 of 4
KINDER 'MORGAN
Metallurgical Investigation Report NGI-09-01
Figures 1 and 2. Views of submitted pipe samples marked with the pipe number (beginning with
"L-08"), the heat number (identified with "HT") and the assigned An-Tech Laboratories job
numbers 08-3468 through 08-3497.
Page 2 of 4
KINDER - MORGAN
Metallurgical Investigation Report NGI-09-01
Table 1
Transverse Pipe Body Tensile Test Results
NPS 42 x 0.888" WT API 5L Grade X70 Linepipe
An-Tech Pipe No. Heat No. ASL No. Yield Tensile % j YT Ratio
Job No Strength Strength Elongation
(ksi) (ksi) in 2"
08-3468 L08-B-2493: Y912568 U32-B-560 76.1 92.6 47.701 0.82
08-3469 L08-C-03863 ! Y912592 LJ32-B-01074 84.2 95.5, 42.40 0.88
08-3470 L08-B-2517 : Y912612 ' L/32-B-573 84.2, , 99.2' 42.15 0.85
08-3471 : L08-C-03888 ''' Y912749 -11.2S2-B-01092 79.9 95.11 42.20 0.84
08-3472 ; L08-C-03862 Y912779 , L/32-B-01093 .„ i 81.0 96.2 39.95 0.84
08-3473 LO6-C-637921 Y913606 LJ32-B-0197 ' 80.9 96.3r 36.10 0.84
08-3474 L08-C-03870 Y913552 L/32-B-01070 : 76.6 94.3 42.95 0.81
08-3475 L08-C-03931 : Y913608 L/32-B-01133 78.3 94:2 41.00 0.83
08-3476 L08-C-03737. Y922033 L/32-B-01091 79.6 96.8 40.45 0.82
08-3477 L08-B-02481 , Y935998 " L/32-B-0483 73.3 92.3 42.60 0.79
08-3478 L08-C-4013 Y936501 U32-B-01303' 83.2 98.4 32.60' 0.85
08-3479 , L08-C-03853 Y936509 U32:13-01176 77.1 89.6 40.05. 0.86
- 08-480 L08-C-03859 Sl96583 L/32-13401057 71.6 90.7 42.60 0.79
08-3481 L08-C-03962 Y936584 'L/32-B-01167 78.7 91.9 40.05 0.86
08-3482 L08-C-04956 Y912435 U32-B-01376: 85.8 97.6 38.30 0.88
08-3483 L08-C-03780 ,,,...., Y912815 L/32-B-0993 71.1 88.5 43.15 0.80
08-3484: L08-B-2432 Y912895 L132-B-6 9 71.4 87.2; 44.45 0.82
08-3485 L08-C-04950 Y913535 L/32-B-01362 89.8, 100.8 36.70 0.89
08-3486 ' L08-C-04012 Y913137 ,,, J/32-B-01378 80.9 93.9, 39.70 0.86
08-3487 ' L08-C-03932 : Y913135 i U32-B-01154 77.4: 92.7- 40.70 0.83
08-3488 'L08-C -03977 Y913543 1 L/32-B-01171 76.3 89.5, 43.65 0.85
Page 3 of 4
KINDER MORGAN
Metallurgical Investigation Report NGI-09-01
Table 2
Summary Statistics for Transverse Tensile Test Results
Page 4 of 4
KINDER -li
ORGAN
Metallurgical Investigation Report NGI-09-01
Appendix 1
Calibration Certificates
Page i
CERTIFICATE OF CALIBRATION
This is to certify that the following described machine has been calibrated in accordance with
A.S.T.M. E-4, and found to be within a tolerance of one %.
CALIBRATION APPARATUS:
CELL SERIAL LABORATORY CLASS"A" CALIBRATION
CODE NO. CAPACITY CALIBRATION LAB NUMBER VALUE DATE MANUFACTURER
1 CAL-2 50 Ibf TX. DEPT OF AG. G-000000410 1 Ibf 02/11/04 RICE LAKE
2 CAL-3A 600 Ibf N.S.T.L. SJT.01/109176 20 Ibf 07/20/07 ADMET
3 CAL - 5 6,000 lbf N.S.T.L. SJT.01/109176 200 Ibf 07/20/07 ADMET
4 CAL - 6 60,000 Ibf N.S.T.L. SJT.01/109176 5000 Ibf 07/20/07 ADMET
5 CAL-9 600,000 Ibf N.S.T.L. SJT.01/109176 25000 Ibf 07/20/07 ADMET
VERIFICATION METHOD . Elastic Calibration Device and/or Standard Wts. Values Corrected to 74T. Room Temperature 74'F
Method of verification and pertinent data is in accordance with A.S.T.M. E-4. The testing device(s) used for
this calibration have been verified per A.S.T.M. E -74, and are directly traceable to N.I.S.T. This calibration
has been performed in accordance with ANSI/NCSL Z540-1, ISO/IEC 17025, and NRC 10; Part 21.
By:
Date of Calibration: OCT 21, 2008 Frank P. Rotecki
Date of Recall: OCT 31, 2009 CALIBRATIONS, INC.
Certificate No: 080465 P.O. Box 2966
Conroe, Tx. 77305
800/848-2953
This is to certify that the following Extensometer/ Extensometer System has been calibrated in
accordance with A.S.T.M. E-83. This calibration has been performed in accordance with
ANSI/NCSL Z540-1, ISO/IEC 17025, and NCR 10; Part 21.
VERIFICATION EQUIPMENT:
Type: Starrett Differential Screw Translator
Serial No.: CAL-1A
Verification Date: April 2, 2007
MST Traceability: ATS-0568 & 0560
Accuracy: .00005"
INSTRUMENT:
Gage Length Measured: "By Direct Measurement"
1) 2.0 "
2) 2.0"
Error 0.0 °A
Calibration Position: Vertical Axis
Temperature: 74° F
Attachment Method: Spring Clamps
Recorder Serial No.: N/A
Recorder Manufacturer: N/A
CALIBRATION MAX.
RANGE FACTOR ERROR CLASS
DIRECT 1 .000060 " B-1
By
Date of Calibration: OCT 21, 2008 Frank P. Rotecki
Date of Recall: OCT 31, 2009 CALIBRATIONS, INC.
Certificate No: 080466A P.O. Box 2966
Conroe, Tx. 77305
800/848-2953
DATA SHEET
By: 111,/Zbi
Date of Calibration: OCT 21, 2008 Frank P. Rotecki
Date of Recall: OCT 31, 2009 CALIBRATIONS, INC.
Certificate No: 080466B P.O. Box 2966
Conroe, Tx. 77305
800/848-2953
This is to certify that the following Extensometer/ Extensometer System has been calibrated in
accordance with A.S.T.M. E-83. This calibration has been performed in accordance with
ANSI/NCSL Z540-1, ISO/IEC 17025, and NCR 10; Part 21.
VERIFICATION EQUIPMENT:
Type: Starrett Differential Screw Translator
Serial No.: CAL-1A
Verification Date: April 2, 2007
NIST Traceability: ATS-0568 & 0560
Accuracy: .00005"
INSTRUMENT:
Gage Length Measured: "By Direct Measurement"
1) 2.0"
2) 2.0"
Error 0.0 To
Calibration Position: Vertical Axis
Temperature: 74° F
Attachment Method: Spring Clamps
Recorder Serial No.: N/A
Recorder Manufacturer: N/A
CALIBRATION MAX.
RANGE FACTOR ERROR CLASS
DIRECT 1 .000050 " B-1
By:
Date of Calibration: OCT 21, 2008 Frank P. Rotecki
Date of Recall: OCT 31, 2009 CALIBRATIONS, INC.
Certificate No: 080467A P.O. Box 2966
Conroe, Tx. 77305
800/848-2953
DATA SHEET
By
Date of Calibration: OCT 21, 2008 Frank P. Rotecki
Date of Recall: OCT 31, 2009 CALIBRATIONS, INC.
Certificate No: 080467B P.O. Box 2966
Conroe, Tx. 77305
800/848-2953
Project NPS WT Grade Plate/ Coil/ Product Form Plate/ Slab/ Coil Country Pipe Supplier Pipe Supplier
Slab Supplier of Origin Location
MLC* Slabs supplied by Mittal Steel Lazaro Cardenas (MLC). Plates rolled by JSW (Baytown, TX).
MLC** Slabs supplied by Mittal Steel Lazaro Cardenas (MLC).
Plates/ coils rolled by Evraz-Oregon Steel Mills (Portland, OR).
MSG= Mittal Steel Galati(Romania)
TISCO= Taiyuan Iron & Steel (China)
POSCO= Pohang Iron & Steel (South Korea)
WISCO= Wuhan Iron & Steel (China)
AHMSA= Altos Hornos de Mexico
page 1 of 1