Вы находитесь на странице: 1из 12

SUPRA.

LYTE
THE ULTIMATE OUTDOOR
AREALUMINAIRE
SUPR/I-LYTE fiom
WIDE.LITE:
NEWADVANCED DESIGN
FORTODAYS
PERFORMANCE I{EEI}S
With today's high energy costs, it's
more important than ever to specily
energy efficient systems for area light-
ing designs. The new Supra-Lyte lu-
minaire trom Wide-Lite is the perfect
choice lor parking, roadway, and area
lighling tasks. with no compromise in
appearance eI perf ormance.

lhe llghting experts at Wide-l ite uli-


lized advanced materials and technol-
ogies to design the Supra-Lyte. The
result is a long-life luminaire that
provides maximum performance, effi-
ciency, durability, and ease of installa-
tion and maintenance.

FUNCTIONAL SWLING
The Supra-Lyte housing features a
square shape with smooth, rounded
contours and a dark bronze finish to
blend wrth the architectural environ-
ment. To coordinate with other color
The optics are so effective that a 250 illumination with qreater enerqv eff -
schemes, optional black, silver and
white finishes are available. watt HPS lamp can produce the same ciencv than a sinqle 1000 watt
peak rntensrties as a 400 wall HPS luminaire. Dual lamp models are avail-
The contemporary housing is as func- lamp in typical luminaires. able for both HPS and metal halide/
HPS combination and offer the
tional as it is stylish. The square
Substantial energy savings can be advanlage of switching off one amp
shape optimizes the distribution of a
achieved when Supra-Lyte is ordered for lower leve illumination whlle
square Type V pattern with no waste-
with the optional Bi-Level switching retaining the uniform Type V pattern.
ful light overlap. And, unlike most
Type V luminaires, the Supra-Lyte has syslem. Dunng off-peak hours. lumi-
naires can be switched to provide low
no structural arms or supports to de-
level illumination and reduce operat-
NON.METALLIC
tract from its appearance or cast DESIGN
shadows. The ballast is located in an inq costs up to 75%.
inlegral ballast maslf iller assembly Supra'Lyte has an exclusive light-
away from the lamp heat. Thrs design UNIOUE DUAL L/AMP weight non-metallic optical housing. lts
assures cooler operation and longer SUPRA.LYTE construction features heat and impact
life Jor the ballast components, and resistant acrylic with an opaque upper-
easier installation of the lightweight For areas requiring higher light levels, half and crystal clear, UV stabillzed
optical housing. a dual lamp Supra-Lyte is available. non-yellowing lens.
The dual 400 watt HPS (800 watts
Perfect for new construction or retrofit total) Supra-Lvte produces similar GLARE OONTROL
projects, the Supra-Lyte features a
universal fitter for mounting to round Supra-Lyte provides maximum inten-
tapered poles and 5" and 6" square sity between 68 and 70 degrees, and
poles with 4" OD tenons. meets l.E.S. roadway cut-off criteria
for glare control. For "no-trespass"
HIGH EFFICIENCY illumination near adjacent property,
and for perimeter and roadway appli-
Supra-Lyte otfers both initial and life- calions. Supra-Lyte is also available in
cycle cost savings over typical post a roadway version with a house-side
top luminaires. First, onlv one Type V shield and asymmetric distribution.
luminaire, with it's efficient square dis-
tribution pattern, is required per pole.

Secondly, the Supra-Lyte uses an ex-


tra large reflector and vertical lamp
configuration to achieve maximum
peak intensities for HID liqht sources.
r
I
!

!
x

SUPERIOR Suprc-Lyte pro-


vides a square light
PERFoRMANCE
i! IV OPTIMUM SOUARE
pattern with
rounded contouts
to minimize waste-
I LrcHTPATTERN ful overlap.
I e""arse parking areas and pole
I spacings are oflen rectangular, a
I gqUqre, rather than circular, illumina-
i: tion pattern is ideal. The square pat-
tern allows minimum waste from
pattern overlap.

Supra-Lyte is designed to provide the ------------" Ii


oplimum square, Type V light pattern.
For pole locations near the edges of
the area to be illuminated, Supra-Lyte
is available in a roadway version to
provide an asymmetric, half-square
pattern.

FEWER FIXTURES,
FEWER FOLES
The Supra-Lyte optics are engineered
to maximize light at the peak beam
angle. This allows more liqht to be dis- Supra-Lyte pro-
tributed across the surface area rather vides maximum
than near the pole. Supra-Lyte pro- light output at
vides maximum intensity near a cut- 68"-70' to illumi-
otf ol 70', and meets LE.S. roadway nate areas be-
culoff requirements for glare control. tween poles
A small amount of light is provided tt..-- t.'," ' spaced up to 6
near 80'to reach to the next pole and - ---,,.-,- mounting heights.
illuminate people and vehicles from at | Adequate light at
least two sides. The result is smooth, 80" is provided to
uniform illumination without hot spots reduce shadows
near the poles, or excessive glare or by lighting a ob-
jects from at least
shadows.
s_6x __,, , _-.1 two sldes.
( Not lo scate )
Because Supra-Lyte otfers better
controlof light intensity and distri-
bution, it affords an excellent spacing- ing 0.5 footcandles minimum at any level illumination can be used to save
to-mounting-height ratio of 5 to 6 point.250 watt HPS Supra-Lyte lumi- energy when full lighting levels are not
mounting hejghts. That means fewer naires can be used with the same needed. Bi-Level is available as an
poles or lower mounting heights are pole spacinq as typicat +OO watt lumi- option for all Supra-Lyte single lamp
needed to effectively light an area, so naires. This results in an energy sav- luminaires. ln applications such as
visual clutter and overall expenses are ings of $55 per luminaire per year, parking lots, Bi-Level switching can
reduced. based on 10 hour per day operation provide up to a 757o savinqs in enerqv.
and 100 per KWH energy cost. For use over a standard lighting system.
the same application, dual lamp 400
oosTssAvrNGs watt HPS (800 watts total) Supra- Supra-Lyte luminaires with Bi-Level
Supra-Lyte offers exceptional equip- Lytes offer the same pole spacing as Switching provide a slate-of-the-art
menl and energy cost savings com- most 1000 watt posl-top luminaires. integrated lighting system offering con-
pared to typical post top luminaires. Energy savings amount to $70 per lu- trol flexibility and maximum energy
Only one luminaire is required per minaire per year. lt the dual lamp Su- savings. Typically, the cost of a Bi-
pole, and Supra-Lyte's high efficiency pra-Lytes are switched down to one Level system is paid back through
reduces the number of Iuminaires and lamp for 6 hours per evening, energy energy savings within the 5-year Wide-
poles required per application. ln addi- savings would be $160 per luminaire Lite warranty period. Contact the fac-
tion. the unique ballast mastfitter as- per year, compared to the operation ol tory or your local Wide-Lite represen-
sembly saves on pole equipment costs 1000 watt equipment. tative f or additional inlormation,
by reducing pole height requirements including a free energy savings
by approximately 2 feet per pole. BI.LEVEL OONTROL analysis.

Supra-Lyte's superior performance Wide-l ite s Bi-Level HID Swilching is


provides substantial energy savings. a two level lighting control system de-
For example. in parking areas requir- signed for applications where low
Exclusive Non-
Metallic Optical
Housing

Vertical Lamp
Design

*.

DUAL LAMP LUMINAIRE Unitized Ballast


Assembly
ADVANCED @urlrzeo BALLAST
DESIGN PAGK OFFERS CIOOLER
OPERATION, LONGER
@ucxnrercxr, OOMPONENTLIFE
NON-METALLIC ln most post top lLtminaires, the bal-
OPTICALHOUSING last is located in the same housing as
the optical assembly. This ar.ange-
Supra-Lyte has an exclusive lighl
ment subsrart,ally rncreases mecl-ar -
weight, non-rnetal ic optical housing for
longer life and easier installation. lt's cal stresses on the support structure,
consrrucled 'rorr heat ano 'mpdct .ests,
and allows lamp heat to affect the bal-
tant acrylc. The dark bronze opaque ast components. ln the Supra-Lyte
iuminaire the ballast is located below
upper half is UV resistant acrylic. The lens
is crystal clear, UV-slabi ized, non-yelow-
lhe lamo i1 a uniq,re e'rclosLre lhal
ng and impacl resistant acry ic. serves as both a ballast housing and
a universal mastfitter. The ballast as-
semb y ope.ates al coole. tempera-
Suo'a-Lyte uses a verlrcal lens desig'l tures, reducing heat problems and FASTER INSTALLATION,
to maximize ight transmission and re- extending the life of the components. EASIER MAINTENANCE
duce dirt deprec alron lactors. Hor - The clean lines of the enclosure pro-
zontal lenses reflect a substantial The iightweight Supra-Lyte optical
vlde a smooth transition from Iumi housing and unitized ballast pack re-
amount of light back into the lum - naire to pole, without distracting
naire, and tend to collect dlrt and bugs dLrce labor cosls with rapio. simple.n-
support arms. A full length access stallation. The relamp door, held in
easily. A vert ca le-s allows a raxt- door allows for easy wiring and
mum amount of ight to be transmitted place with two spring-loaded fasteners
maintenance of all ballast compo- and a high temperature teflon hinge,
al lhe beam a1gle. drd s more re- nents, without the need to open the
sistant to dirt accumulation. allows for easy relamping. The ballast
luminaire. access door rs easily removed by
loosening one captive fastener, and
@vERTrcAL LAMP wiring is simplified with a lamp/ballast
DESIGN FOR BETTEB quick-connector.
LIGHT DISTRIBUTION
Supra-Lyte uses the inherent pho- QUALITYTESTED
tometric advantages of a vertical HID AND BACKED BYA3.YEAR
amp for better ligtsl dislributio-. Typi- WARRANTY
cal HID lamps radiate far more light
from the sides of the arc tube rather To assure quality and reliability, the
than from the ends. When horizontal complete Supra-Lyte assembly is
lamps are Jsed i" parkrng applications. wind-tested to 130 mph. lt's also
too much light is directed straight tested tor resistance to vibration, im-
down, causing excessive light near the pact. and metal halide lamp explosion.
pole. Vertical amps put little light and it's U.L. listed.
straight down and allow maximum light
to be reflected in the beam peak. Supra-Lyte ts engineered and built to
Wide-Lite's kaditional high standards.
The end user is protected by a s-year
@exrna LARGE, HtcH. G)uruvensal FETER limited warranty-the longest written
EFFICIENCYPRIMARY FOR NEWOR RETROFIT warranty in the industry.
PATH REFLECTOR INSTALLATIONS
The large, high efficiency reflector The heavy-duty 6 inch by 4 inch O.D.
system, made possible by the ab- cast aluminum mastfitter is sized to
sence of the ballast in the optical handle high winds and vibration. A
housirg. provides beller co-lrot of true vertical set is afforded by four re-
long HID arc tubes. Most of the light is cessed set screws.
reflected only once, achieving supe-
rior "primary path" efficiency. The The Supra-Lyte f tter is idea for new
Supra-Lyte reflector is so effective or relrof t appl cations. lt's designed to
that a 250 watt HPS lamp is capable rnolrnt to lenons on 5" or 6" square
of producing the same peak inten- poles or round tapered po es (4" OD
sities as a 400 watt lamp in other tenon required). Supra-Lyte uminaires
luminaires. may also be mounted in tandem and
wa I moLnred. with appropr ate acces-
sory brackeis.
APPLICATION Typical Type V
"Tear-drop"
GUIDE Pattern

Typical Type V cut-off luminaires


produce a "tear-drop" type ol pho-
tometric distribution. This type ol pat-
tern is designed to reduce glare and
excessive spill light on adjacent prop-
erty. The Supra-Lyte is designed to
reduce glare and spill light as well, but
instead oI a "tear-drop" pattern, it
produces a "bat-wing type of distr-
bution. This creates two important
benelits:
1. A more uniform liqhting installation Supra-Lyte
can be designed because the hot " Batwing"
spot near the base of the pole is Pattern il
eliminated.
2. Poles can be spaced Jurther apart
because the light is "punched" to
the normally low illumination points
between the poles.
The end-user benefits from a Supra-
Lyte application with fewer fixture and
pole equipment requirements and a
more uniform lighting installation, with-
out compromising critical minimum
point illuminance criteria.

SPACING
REOOMMENDATIONS
Table I ILLUN.4INANCE DATA
The folow ng table shows slalistics ior iluminance on a 30 lt. pole. For oiher spacing, pole heighl, or

! E1 Levels in lhe shaded area using (4) S!pra-Lyte


SLN4-400'S luminaires with 400 watl metal halide
lamps (40,000lumens) Each luminaire s mounted
lamp requiremenis, consult your loca Wde-Lle

S] MH 2 25 3 3.5 4.5 5 5.5 6 65


(Spac ng lo Mounting
I
He qht Ralio)

I-l Max mum ro Minimum 1n 20 22 25 32 4.0 16 12.2 21.4

AveragetoMnmum 13 14 1.4 14 1.5 1.5 t.5 2.4 2.7 38

48 3.9 3.1 24 1.9 15 10 85 .73

E_1 l\4inimum 36 2.7 21 1.7 13 10 .85 .52 19

Spacing 60 75 90 105 120 195


(Feet)
)
Table ll ILLUMINANCE DATA
I
The follow ng lable shows statslics for illuminance on a 30 lt. pole. For olher spacing, pole heighl, or
leve s in the shaded area using (2) Supra-Lyte amping requ rements, consult your local Wde Lile

I
SLIV-400-3 uminaires wth 400 walt metal halide
lamps (40,000 lumens). Each luminaire is mounled

Si MH 2 2.5 3 3.5 4.5 5.5 6 65


(Spacing to Mount ng
Heiqhl Rat o)
Maximum to ,1n mum 45 58 66 69 7.1 72 87 121 166 216
x
Average to Nl n r.urn 19 23 23 2.2 2.1 19 2.1 27 34 41

EI .*"'*o 'l
Average

Mnmum
2.6

2.O
2.3

1.0
2.4

.88
1.8

81
1.6

.74
1.5

t5
1.3

.62
12

.45
1.1

.32
10

.25

Spac ng 60 75 90 105 120 135 150 165 180 195


(Feet)
PHOTOMETRIC IilTA
SINGLE LAMP LUMINAIRES DUAL LAMP LUMINAIRES
5H 5Fl

4H 4F
'o.12

a\
-0.25-
o.25 4.12

$
3H 3H

/V o.7
1.0:
-o.7.
- t.0,
\i
#
2N 2H

'(( 1.5 =
,-, 1.5.

\ 2.Q
1H
,z '3.0
2
]H

\\' ,4 i3q '/1, I


,l'\
OH

s "//
OH

t/, \ u/
t\\ \
1H

2H
\
N /,,
t, /
1H

2N

\
I /.
-..-_J-/
---_J----
.
v
3H 3H

4H 4t]

su su
5H 4H 3H 1H 0H lll 2H 3H 4H 5H 5H 4H 3H 2H lH OH 1H 2H 3H 4H 5H

SLS-4OO-S (400 walt HPS) 25'MH SLS-BOO-S (Two 400 wart HPS) 30'MH
6H 6H

5t-l 5H

a.12
0.r 2,
4H
-0.25. 0.25

Iv ls-
7 il
3H 3H
0- - r .o-
1
{' \ ( 7 \
l ft, 7 \l TI
2H 2N
Ls\
]H
l/r 2A
il\ l1 IH
\5.
2.4 t\\
'/ II (1
r
\ ). /
f ''l \\ )\r \ \' \\ a '1
'/lt
A
OH 0t-l

\ \\ S 'a /// /, N
$ SN 7 N v,
1H 1H

\\
'/7
2N
,/ 2H

\ / \
3H 3H

4H
5H 4U 3H 2H ]H OH ]H 2H 3t-t 4H 5H 5H 4H 3H 2H rH 0H 1H 2r-l 3H 4H 5H

SLS-4OO.A (400 walt HPS) 25'MH SLS-800-A (Two 400 watt HPS) 30'MH
Table lll Conversion lvlultipliers Table lV Conversion Multipliers
tulount ng MoLrnl ng
Heighl LU4OO LU25O M5400,BD MVB250/tl He ght LU4OO LU400rLU250 t\tH400 E
(Feel)
25 I 00 58 80 .41 30 100 79 .68
30 .69 40 55 2A 35 l3 .58 50
35 51 30 .41 21 4A 56 38
40 39 23 .31 16 .35 .30
VERSATILITYFOR
ALLAPPLICATIONS
Supra-Lyte is availab e n a variety of
configurations to match application re-
quirements. Single lamp models, for
parklng 1ot and general area lighting
tasks, are available with symmetrical
(Type V) distribution from 250 or 400
watt HPS and metal halide lamps. For
perimeter and roadway applications,
Supra-Lyte may be ordered with an
asymmetrical reflector system and
house-side shield.

For areas requir ng higher ieve s of


illumiralio'r. Supra-Lyle is avai'ab e n
a dual larp vers on.
or two Supra-
Lytes may be mounted in tandem.

FINISHES

mll ]r l
Standard finish for the Supra-Lyte is
an architectural dark bronze. To blend
with the environment, a choice of
optional black, white and aluminum
finishes are ava labie.

@NFIGURATIONS/
DIMENSIONS

Single Lamp Roadway


- 68" Dual Lamp

EPA DATA Effective Projected


Area (Square Ft )
Single Lamp 4.40
363/d' Dual Lamp 4.47
Single Lamp Twin l,4o!nt 8.80
181/a" Dual Lamp Tw n Mount 9.74

Twin Supra-Lyte
OPTIONS aocEssoRrEs The ballast housing shall be extruded
Factory lnstalled Field lnstalled aluminum connected to the cast alu-
minum mastlitter by lour tie rods for
strength in high winds. Ballast access
! WALL MOUNTING door shall be large enough to tacilitate
BRACKET ease of installation and maintenance
Component Catalog No. SL-SW and, shall be secured to ballast hous-
For mounting Supra-Lyte single or dual ing with safety cable. Ballast shall be
lamp with asymmetric distribution and mounted above capacitor, ignitor and
side mounting arm bracket (Sl\rA) to other electrical components to facili-
walls or other flat mounting surfaces. tate cooler operating temperature and
Mounting hardware not included. prolong component life. Supply wiring
strain reliel shall be provided.
tr FUSED BALLAST
fISIDE MOUNTING
Fuses are KTK 30 amp. tr REFLECTOR
Ordering example: Rellector shall be high purity specular
ARM BRACKET 120V or 277V systems, anodized aluminum to insure maxi-
Component Catalog No. SMA Component Catalog No. F1-KlT mum efficiency. Fixture shall meet IES
For mounting Supra-Lyte luminaires 208V,240V or 480V systems, Compo- delinition of cutotf distribution and be
llush mount to the side ol straight nent Catalog No. F2-K|T capable of providing square type 5
square poles. Arm and ballast housing distribution, or asymmetric distributjon
are aluminum extrusions welded and with house-side shield.
blended together for a one piece look.
ldeally suited for twin mounting at 180" T N SOCKET
either the single or dual lamp Premium glazed porcelain mogul base
luminaires.
Ordering example:
{ socket shall be shrouded with high pu-
rity specular anodized aluminum to
sLS-400-s-277-SMA-DB assure even light distribution. Socket
shall be pulse rated at 4KV.
N BI-LEVEL SWITCHING
BALLAST tr BALLAST
Component Catalog No. BL Ballast shall be prewired high power
Available lor single lamp models only. factor design with 20 degrees start-
For use with Bi-Level switching system N POLE MOUNT ing lor metal halide (-40 degrees lor
conlrols. See Lighting Systems section ADAPTER BRACKET HPS). Coil windings shall be copper.
of the Wide-Lite catalog for full details. Component Catalog No. All parts shall be field replaceable as
Ordering example: SPB-14DI\,42180-DB a unit or as individual componenls.
SLS-4OO-S-277.D8.8L Permits twin mounting of Supra-Lyte
luminaires with side mounting arm
bracket (SMA) to top of round poles. tr MOUNTING
N FNSHES Pole top tenon must be 4" OD and a
Standard mounting shall be post top
Optional lactory acrylic enamel (op- tenon mounting (4" OD pipe tenon
minimum 7" in length.
tical housing) and polyester powder 5%" high) with optional side arm and
coating (ballast housings) are wall mounting avajlable.
available. SUPRA.LYTE
Catalog Component No. SPECIFICATIONS tr FINISHES
BLACK BK Optical housing shall be UV resistant
WHITE W tr HOUSING acrylic. The ballast housing shall have a
SATIN ALUi,4INUM SA The housing shall consist of an optical polyester powder coating. Standard fin-
housing and ballast housing such that ish shall be dark bronze with optional
the heat trom the lamp is isolated from black, white, and aluminum finishes.
the ballast to insure longer component
lile. Luminaire shall be wind tested to
130 mph. All hardware shall be corro- tr LISTINGS
sion resistant. The optical housing Fixture shall be U.L. Listed for wet lo-
shall be thermolormed Plexiglas@ "G" cations including metal halide lamp
acrylic with opaque upper half and rupture test.
crystal clear lower half. Silicone gas-
keted relamp door shall open inward tr USER PROTECTION
on a continuous teflon hinge and Fixture shall carry a published 5-year
shall be secured with two 74 turn limited warranty.
spring loaded fasteners. Optical hous-
ing shall be secured to ballast housing
by means of a cast aluminum support
frame, and 4 recessed setscrews.
SUPRA.LYTE
ORT'ERINGGUIDE

SL s 400 s -277- DB
I
LUMINA]RE VOLTAGE OPTIONS
SEF ES 120,204 ACCESSOBI!S
240,2lT
(s on M) (s oR A)

Cata ogr Primary L ne Line Curreni Baliast'. Esi Shpg.


Number Voltaqe Watts Startino Ooer. Tvoe Wt (lbs)
F xlures for High Pressure Sodium Larnps 40'F to
Sinqle Lamo 400 Watt E lB Envelope l\y'oqu Base
SLS 400 ( ) (4) DB 120,248 46s 'i 4 30 2 ,18 Regu aiing 50
SINGLE LAI'i1P 244t277 2.15'T.86
480 1 .47

Sinq e Lamp 250 Watt E'18 Envelope Moqul Base


SLS-250-( )-(4)'DB 12ot2oa 300 .t 2 75,1 60 Reg! aling 50
240t277 1 38,1 20
480 069
DJal I d^lp 800 Wdn (T^o 400 Walr) f 'B frvelope VoqL Bdse
SLS-800 ( ) (4) DB 120t208 930 ':, B 60,4.96 Regulating 65
240i277 4 30t3 72
480 + 2.14
Dua Lanrp 650 Watt (250 Watt and 400 Watt) E I B EnveLope Moq! Base
sLS 6s0 ( ) (4) DB 120t208 765 7.05,4.08 Regulaiing

o
65
240t277 3 5313 06
480 176
Fixture for HPS,I\,4eia Ha ide combination amp 20'F io
Dua amp 800 watt (400 watt T-18 N4etal Ha de,400 wat E-18 HPS)r
DUAL LAI\,4P
sLsiM-800-( )-(4)-DB 120t204 920 8 30,4 78 Begu ating 65
240t277 415361
480 207
Fixtures tor N,4eta Halide Lamos to
2A'F
Srrq p I drp r00 Warr BT F- l7 Fr vp opp Voqu Baro
SLN,4-400-( )-(4)-DB 12Ai2OA 455 'i 4 00,2.30 Begulating 50
240i277 2.00i1.75
480 1.00
Sinq e Lamp 250 Wati BT,E-28 Envelope Moqu Base
sLN.4-250-( )-(4)-DB 12Ot20A 254 2.60,1.50 Begulatlng 50
240i277 1 .30'1 .12
440 065
1 SPECIFY REFLECTOF TYPE FROM DISTF BUT ON GUIDE
2 ALL BALLASTS AFE H GH POWEF FACTOR
3 AT T ME OF CATALOG PR NTING ONLY PI] LLIPS OFFEBS
-!t. Lr\vo ! vF400 T (c-o. r.D Bw w DT t-rr
L

4 VOLTAGE: SIANDARD llD LUM NAIFES AFE FIIRN SHE0 W Tn HPF


ROADWAY SING LE VOLTAGE BALLASTS FOF 1 20v. 208! 2 10v. 277v o r 480v
TO SPEC FY ADD DESIBED VOLTAGE TO CATALOG NO
EXAMPLE: S1S.,100.( ).277.D8

.,,,-- -- --..:\.
+,LEss rHAN oPERATtNG
.-, a- - .
\ OPTIONS Suffix ACCESSORIES Sutfix
(,) (Factory lnstalled) (Field lnstalled)
I i
Side Mounting Arm Bracket SMA Wa I Ny'ounting Bracket SL-SW
\:::-----jrl.,' r'.i:r:"r:,'\:r':, Bi Leve Switching BL Fused Ballast 120 or F1-KIT
Optiona Finishes: 277 voll
(in lieu of DB Dai( Bronze) Fused Ba last 208. 240 F2-KT
S A Black BK or 480 volt
Symmetric Asymmetric White Pole lvlount Adapter SPB-14DN,42180-DB
Distribution Distribution Satin Aluminum SA Bracket
ALUMINUM POLES STEEL FOLES
s"STRAIGHT SQUARE 5'STRAIGHT SQUARE
O sPEcrFrcArroNs
,[
SPECIFICATIONS
N SHAFT
Extruded 6063 alloy aluminum tubing
t] SHAFT
Weldable grade carbon steel structure
and heat-treated to produce a T6 tem- tubing with a uniform wall thickness ol
pered, supplied with an aluminum .120" (11 ga.) or .188 (7 ga.). The pole
4" OD standard pipe tenon 51/z" high. shaft material shall conform to ASTL4-
4-500 Grade B with minimum yield
N ANCHOR BASE strength o146,000 psi or when noted,
Cast from 356 alloy aluminum with T6 TT-70 with a minimum yield strength
temper, fully welded (outside top and of 70.000 psi. Shaft shall be unitor-
inside bottom) to the shaft. The an- mally square in cross-section with flat
chor bolt and nut recesses in the an- sides. small corner radii and excellent
chor base casting shall be flush torsional properties. Supplied with
covered by four tamper resistant alu- 4'' OD standard pipe tenon 5%" high.
minum nut cover discs.
tr ANCHOR BASE
tr HAND HOLES Fabricated lrom a structural quality
hot rolled carbon steel plate that
Peripherally reinforced covered hand
hole centered 18" above the bottom ol meets or exceeds a minimum yield
the standard. Opening is rectangular strength oI 36,000 psi. The anchor
in shape 21/2" x 4" with the major di- base telescopes the pole shape and is
mension along the vertical axis. circumf erentially welded top and bot-
tom. Supplied with two-piece base
cover.
tr ANCHOR BOLTS
lncludes four L-shape anchor bolts
with each bolt furnished with two nuts. ! HAND HOLES
flat washers and one lock washer. Oval reintorced, having a nominal 3"
x 5" inside opening 18" above base.
tr STANDARD FINISHES
f] ANCHOR BOLTS
Duranodic Anodized finishes.
ADB Anodized Dark Bronze lnclude four L-shape bolts, each fur-
ABL Anodized Black nished with two regular hex nuts.
ANA Anodized Natural
tr STANDARD FINISHES
N OPTIONAL FINISHES Thermosetting polyester powder-coat
Painted baked acrylic enamel finish paint.
applied by liquid electrostatic process. DB - Dark Bronze
W-White BL - Black
W - White
Aluminum Pole Ordering lnformation OG - Oyster Gray
For Single/Due.l Lamp Models
MTNG POLE FATED(1) WALL
n OPTIONAL FINISHES
- Prime Painted
AEIGHT CATALOGNO MPH TI]ICKNFSS P
PASS 155 4,0 ADB 100 .188
G - Hot Dipped Galvanized
PASS 205 4,0 ADB 100 .250
90 .250
Steel Pole Ordering lnformation
For Single/Dual Lamp lvlodels
NOTE:
(1) NIPH shown are based on luminaire EPA of 4.90
and luminaire weight of 60 lbs. Consult iactory MTNG POLE RAIED (1) WALL
ior tw n arm and other rnounting requirernenls. HEIGHT CATALOG NO. MPH TI"]ICKNESS
15 Fr. SP-155 4.0 BC DB 100 11 ga.
20 F1. SP 205 4.0 BC DB 100 11 ga.
25 Fl. SP 255 4.0 BC DB 100+ 11 ga.
30 F1. SP 305 4.o-BC-DB 100* 11 ga.
* Minimum Yleld 70.000 PSI

SQUARE POLE ANCHOR (1) N,4PH shown are based on luminaire EPA of 4.90
and luminaire weight ol60lbs. Consult factory
BOLTAND BASE DEIAIL for tw n arm and other mounlinq requirements.
ABCD E
Sze & Bolt Boll Boll Conduit D rnension
C,rcle P o.eclior SrlF Openr1q Heighl
Specilicatjons and drmensions
5" Sq Aluminum 31h" Y!" \ 25" 21/1', 'lOY2' are subjecl lo change
5" Sq. Steel '1" t 36'. 1"
HIGH PERFORIIAI{CE HID LIGHTING ard UGHTING OOIIITROIS

Aktra ll Luminaircs
Wide-Lite's Aktra ll architectural lumi-
o
naires feature the patented AKTRA high
eff iciency cut-off retlector system.
AKTRA provides smooth illumination
with superior control ol spill light lor ar
chitectural, site and building facade
lighting. Available lor 70 to 400 watt HID
lamps, a choice of mounting configura-
tions, and optional Bi-Level Switching.

Aktra lll Luminaires


Newest addition to the AKTRA product
line, Aktra lll luminaires leature a unique
clear polycarbonate, UV-stabilized lens lor
a distinctive daytime appearance. At ni9ht,
Aktra lll luminaires provide superior illu-
mination with a solt, attractive glow that
is ideal for architectural site lighting and
parking areas. The high quality specifi-
cation features and options are similar
to Aktra ll.

Bi.Level Switching
Wide-Lite's Bi-Level HID Switching is a
two level lighting control system de-
signed for applications where low level
illumination can be used to save energy
when full lighting levels are not needed.
Bi-Level Switching can provide up to a
75% savings in energy use over a con-
ventional lighting system. ldeallor park-
ing lots, security areas and airports, Bi-
Level is available as an option for most
Wide-Lite luminaires and tloodlights.

Wide-Lite is represented in your area by:

! GEI0E cfinplny
P.O. BOX 606 BULLETIN 0378-0890
SAN MARCOS, TEXAS 78666 Printed in U.S.A.
(512) 392-s821, FAX (512) 353-5822 Copyright O 1990

Вам также может понравиться