THE ELECTRICAL INSTALLATION WORKS HEREIN SHALL E DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATION WITH THE APPLICABLE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE. THE RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITY
AND THE REQUIREMENT OF THE LOCAL POWER COMPANY.

2. THE ELECTRICAL WORKS HEREIN SHALL BE EXECUTED BY EXPERIENCED MEN UNDER THE DIRECT SUPERVISION OF A DULY LICENSED ELECTRICAL
ENGINEER. WORKS SHALL BE NEATLY PLACED. SECURELY FASTENED AND PROPERLY FINISHED.

3. ALL MATERIALS SHALL BE NEW AND SHALL BE CONFORMED WITH THE PROVISION OF THE UNDERWRITERS LABORATORIES (UL) INC. IN SUCH
CASE WHERE SUCH STANDARDS HAS BEEN ESTABLISHED.

4. ALL REVISIONS AND CHANGES IN THE PLANS SHALL BE DIRECT OR WRITTEN APPROVAL OF THE
DESIGN ENGINEER. GENERAL NOTES:
5. ALL WIRES SHALL BE COPPER AND WITH FLAME RETARDANT, MOISTURE AND HEAT RESISTANT THERMOPLASTIC INSULATION MATERIAL
(THHN) MANUFACTURES BY PHELPS DODGE. MINIMUM SIZE FOR POWER AND LIGHTING CIRCUITS IS 3.5mm STRANDED.

6. ELECTRICAL WIRING INSTALLATION SHALL BE AS FOLLOWS:


RSC/EMT CONDUITS BRAND: NICHI OR APPROVED EQUIVALENT
FOR POWER AND LIGHTING SYSTEM
RSC/EMT CONDUITS BRAND: NICHI OR APPROVED EQUIVALENT
FOR TELEPHONE AND COMMUNICATION LINES

7. ALL OUTLET OXES SHALL BE GALVANIZED GAUGE NO. 16 DEEP TYPE WITH FACTORY KNOCK -OUT

8. ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE," SQUARE".

9. ALL WIRING DEVICES SHALL BE AS FOLLOWS:


FOR SINGLE/DUPLEX CO, IT MUST BE GROUNDING TYPE FLUSH MOUNTED.
FOR WALL SWITCHES, IT MUST ALSO BE FLUSH MOUNTED
FOR VOICE/DATA OUTLET- RJ45 TYPE

10. MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS:


A.) CONVENIENCE OUTLET 300MM ABOVE FLOOR FINISH
B.) TELEPHONE OUTLETS 300MM ABOVE FLOOR FINISH
C.) COMPUTER OUTLETS 300MM ABOVE FLOOR FINISH
D.) LIGHT SWITCHES 1400MM ABOVE FLOOR FINISH
E.) PANEL BOARDS 1800MM ABOVE FLOOR FINISH

ALL MOUNTING HEIGHTS SHALL BE SUBJECT TO ARCHITECTS APPROVAL PRIOR TO INSTALLATION.


C2 11. PROVIDE ELECTRICAL GROUNDING SYSTEM AS PER PHILIPPINE ELECTRICAL CODE.

12. ALL CIRCUITS SHALL BE WIRED ACCORDING TO PANEL BOARD SCHEDULE.

C3 13. ALL FLUORESCENT BALAST SHALL BE HIGH POWER FACTOR, PRE-HEAL, RAPID START, STRIPPING LOADED LAMP HOLDER.
C4
14. COORDINATE WITH BUILDING ENGINEERING REGARDING TAPPING POINT FOR POWER SUPPLY, PINT OF SALES, AND TELEPHONE SYSTEM
C1
15. PROVIDE APPROVED TYPE HANGERS AND SUPPORTS DIRECTLY CONNECTED TO CEILING SLAB.
C6
C5 16. COVER ALL JUNCTION BOXES (NO EXPOSE WIRING).

C8 C7 17. PROVIDE METAL CASING FOR TRANSFORMERS OF HALOGEN TRACK LIGHTS AND NEW LIGHTS (IF ANY)
S1
S2 18. ALL WIRING FOR POWER LIGHTING SHALL BE INSIDE A METALLIC CONDUIT OF APPROVED TYPE. USE
INTERMEDIATE CONDUIT (IMC) OR RIGID STEEL CONDUIT (RSC) OF HIGH QUALITY. ALL PIPES SHOULD BE
PROVIDED WITH SUPPORT HANGERS.

LEGEND AND SYMBOLS:


LIGHTING AND POWER SYSTEMS:

LIGHTING & CONVENIENCE OUTLET LAYOUT


SCALE : 1 : 50 METERS
UPS

LP
3

SH

S1
S2

APPROVED BY: SEAL PRC. REG. NO. : APPROVED AS TO PLAN: CAD BY : SHEET NO.
PROJECT TITLE:

P. T. R. NO.

E
DATE ISSUED:

PLACED ISSUED :
PROPOSED ZABROSO PIZZA & PASTA OUTLET MR. DARWIN A. CANTILLER CHECKED BY : 1
PROFESSIONAL ELECTRICAL ENGINEER OWNER
5 7
ADDRESS: T. I. N. : LOCATION : G/F - GAISANO CAPITAL OTON J.C Zulueta Street, Oton, Iloilo ADDRESS : Banica Tulay, Brgy. Banica, Roxas City, Capiz