RESPIRA

Invasive ventilation based


on automation and monitoring
of manual resuscitation bag
device.com
a product of GPAINNOVA.

Authorized by Spanish Agency of


Medicines and Health Products.

Developed together with: Partners:


Automation and monitoring Accuracy and safety
of manual resuscitation bag R E S P I R A is able to emulate human respiration
through mechanical compression of a resuscitation
R E S P I R A is the first high performance R E S P I R A has been designed to work
bag using a piston with an electric linear guide
invasive ventilator based on the automation intensively, and without interruption. It has
adapting to the needs of the patient.
of manual resuscitation devices.An intensive different ventilation modes, providing great
care device that allows monitoring and versatility to treat patients in different
control of key ventilation parameters. invasive ventilation phases. Synchronization
An ideal device to cover shortage Assisted ventilation modes (with trigger sensitivity
of conventional automated medical adjustment) allow perfect patient-ventilator
ventilators on emergency situations, while synchronization by bringing mechanical ventilation
ensuring remote patient monitoring. closer to natural ventilation precisely.
Invasive ventilation based
on automation and monitoring
of manual resuscitation bag

Usable with any type


of resuscitation device
Manual and software
in 6 languages
Spanish
English
French
Russian
German
Portuguese
Flux sensor
Pressure sensor

Different Parameter
Easy and intuitive Heavy duty highly reading
ventilation
operation automated device in real time
modes

Portable device, Remote control up to 16


Security control Graphs display
does not require devices per control
with alarm system in real time
installation through Wi-Fi
SIEMENS PLC control with a
simple and intuitive interface
for maximum safety

Safety Alarm
System
Built-in alert system shown in device screen
prevents incidence or deviation on respirator
parameters. It also incorporates a acoustic
alarm system.

- Maximum volume (adjustable)


Parameter Graphs - Minimum volume (adjustable)
display in display in - Maximum (PPI) pressure (adjustable)
- Minimum (PEEP) pressure (adjustable)
real time real time - Apnea (*) Available with the Advanced model
- Actuator error
- Insufflation volume - Insufflation flow - Breathing circuit disconnection
- Inspiration and expiration pressure - Inspiration and expiration pressure - Voltage drop
(maximum, minimum and plateau) - Insufflation volume
- Oxygen supply via FiO2 sensor with
independent display (optional)
Volume and pressure Advanced mode
sensor on each side available for
for more comfort sensor calibration
This device collects air flow, pressure and tidal
volume from sensors to control the amounts
delivered to patient, safety system and it does
not require installation.
Ventilation parameters

Tidal volume control


This device adjusts the volume of air supplied to the patient (tidal volume) by
controlling the actuator stroke which compress (AMBU ) device.
®

Ratio I:E
R E S P I R A allows to perfectly assist human breathing adjusting the times of expiration
to get a desired ratio of inspiration/expiration. Expiration can be adjusted from 1 to 3
with steps of 0.5.

Frequency
The system controls breath frequency between 10 to 30 rpm.

Controllable pressure by PEEP valve

Trigger sensitivity
(-1 cm, -2 cm, -3 cm H2O) vs. PEEP
Ventilation modes R E S P I R A Advanced
This model allows manual control and additionally automated control. The alerts and
real-time readings are processed modifying the ventilation parameters required by the
setup made by the physician according to the needs of the patient. It allows weaning

R E S P I R A Basic mode by detecting the patient’s inspiration pressure and incorporating trigger
sensitivity adjustments.

Basic version designed to treat patients in deep


sedation. Automates and increases the precision of
the manual intervention performed by a physician
with a resuscitation bag, incorporating readings of key
parameters for breathing.
It is a manual control device which displays alerts and Volume
readings in real time. Assist-Control Volume Assisted
Weaning mode: the patient is the trigger This ventilation mode is usable for
of ventilation between frequencies. This weaning ventilation,. The patient trigger
ventilation mode includes the possibility the frequency. The physician set up tidal
of autoadjustment of minimum and volume, Trigger sensibility and apnea time.
Control Volume maximum tidal volume and PIP pressure. This ventilation mode includes the
possibility of autoadjustment.
Ventilation mode with target tidal volume adjusting
stroke of linear actuator. Itis a non assisted
ventilation mode designed for sedated patient Autoadjust Trigger
treatment. The physician set up tidal volume,
Self-adjustment setting set up ti- R E S P I R A allows to adjust trigger
frequency and I:E Ratio. This ventilation mode
dal volume limits according to preset sensitivity (-1cm, -2cm, -3cm H2O) vs.
includes the possibility of autoadjustment of
maximum inspiratory pressure. At the PEEP
minimum and maximum tidal volume and PIP
same time, it allows pressure adjust-
pressure on R E S P I R A A d v a n c e d version.
ments based on tidal volume limits.

Available in both versions Only available in R E S P I R A


Advanced version.
Functionalities comparison of
R E S P I R A device versions

Ventilation modes Basic Advanced

Volume Controlled

Volume Assist-Control

Volume Assisted

Autoadjust (*) Visualization of graphs in real time Basic Advanced


(*) Autoadjust: Self-adjustment setting set up tidal volume limits according to preset maximum
inspiratory pressure. At the same time, it allows pressure adjustments based on tidal volume limits. Inspiration and expiration pressure

Ventilation parameters Insufflation flow

Tidal volume adjustment Insufflation volume

Ventilation frequency 10 - 30 rpm Data register

I:E Ratio adjustable from 1:1 to 1:3 with intervals of 0.5 Safety alarm system with visual and acoustic alerts

Controllable pressure by PEEP valve Maximum Tidal Volume (0 to 999ml)

Trigger sensitivity (-1 cm, -2 cm, -3 cm H2O) vs. PEEP Minimum Tidal Volume (0 to 998ml)

Parameters for ventilation monitoring Maximum inspiration pressure (0 to 60cmH20)

Insufflation volume Minimum expiration pressure (0 to 60cmH20)

Inspiration pressure (maximum and plateau) Apnea

Expiration pressure (minimum pressure) Actuator error

Time counter Breathing circuit disconnection

FiO2 sensor (Optional accessory) Voltage drop


Up to 16 real time
connected devices
Capable of controlling 16 connected
R E S P I R A devices from a single PC, and
monitoring and controlling them in real
time, it allows medical staff focus on other
priority duties.
Single ID and
connectivity status
The device can be onsite and remotely
operated. Remote control is supported
by a connectivity module connected to
RESPIRA.

This accessory includes its own Wi-Fi,


transmitting all data directly to operator’s PC
preventing collapse on facilities’ network.

No pre-installed
data network required

Remote control and monitoring through


Respira Access Point (Ref. GPA009500)
and Connectivity Module (Ref. GPA009889)
provided as accessories.
Battery (SAI) with up Ventilator cart to
to 3 hours of autonomy transport the device
As safety is our major concern, we offer a battery as
and accessories safely
accessory which prevents interruption of the ventilator’s
Transport your ventilator and accessories quick and
operation in the event of voltage drop in the hospital or
safely in ICUs and emergency departments. The cart is
medical center. It has an autonomy of up to 3 hours of
highly mobile and ergonomic with a holder to facilitate
continuous operation.
the movement of cables, pipes and consumables.