Вы находитесь на странице: 1из 2

1 NPSHa  NPSHr + Safety Allowance (Normal case design) NPSHa = Available Net Positive Suction Head, m

Safety Allowance = 1 mH (minimum)


6
2 NPSHa = {[10 ( Pa - Pv)] / rg } ± hs - hfs NPSHr = Required (pump) Net Positive Suction Head, m
Pa = Absolute pressure put on liquid surface of suction side tank.
Pa = 0.1013 MPa 10.33001 m H2O (if opened to atmosphere, it is atmospheric pressure, Normally
T (site) 30 °C 1 atm = 0.1013 MPa), MPa
So, Pv = 4242 Pa Pv = Vapor pressure of liquid at temperature of pump inlet, MPa
0.004242 MPa hs = Height from liquid surface of suction side tank to the center of pump inlet port, m
hs = -4.55 m (Site Condition) water level above center of pump, then --> +
hfs = 1.36 m, (from pressure loss table) water level below center of pump, then --> -
r = 1020 kg/m3 hfs = suction pipe resistance, m
r = Density of liquid, kg/m3
6
Then NPSHa = {[10 ( Pa - Pv)] / rg } ± hs - hfs g = Gravitational acceleration, 9.8m/sec2
NPSHa = 3.800 m T = ambient temperature, °C

Page 1/2
1 2 3 4 5 6 7 8

DWG. NO.

PN TN
A A

B B

PLAN

C C

D D

OWNER

PROJECT TITLE

OWNER'S ENGINEER Status


Approved
Approved with Comment
Not Approved
E E
Reviewed
Reviewed with Comment

EPC CONTRACTORS

TITLE

ELEVATION VIEW CERTIFIED FOR


CONSTRUCTION DWG DSGN CHK APPR.
F
BY BY

DATE
DATE

PROJ. NO. CTCI DWG NO. REV.

CUSTOMER DWG NO. REV.


PROJ.
REV. DESCRIPTION BY CHK APPR. DATE
APPR.

1 2 3 4 5 6 7 SCALE 1:40
The content of this document is SENSITIVE information received, produced, or kept in CTCI Corporation (CTCI) due to agreement which shall limited to access and use this sensitive information within a relevant work scope under a specific project. No one is allowed to copy, reproduce, distribute publicly or disclose in whole or in part to any non-relevant person without CTCI's prior and written consent.