0 оценок0% нашли этот документ полезным (0 голосов)
92 просмотров2 страницы
This document contains two matching quizzes about electronic chart display and information system (ECDIS) concepts. The first quiz matches theories in column A to proponents in column B. It covers topics like what the question mark represents on an ENC chart, IMO requirements for updating ECDIS, display modes, and requirements for SENCs and ENCs. The second quiz also matches column A concepts to column B explanations or standards. It addresses presentation size for backup ECDIS, ECDIS display chart representation size, mandatory ECDIS inputs, and indications of overscale or underscale on ECDIS.
This document contains two matching quizzes about electronic chart display and information system (ECDIS) concepts. The first quiz matches theories in column A to proponents in column B. It covers topics like what the question mark represents on an ENC chart, IMO requirements for updating ECDIS, display modes, and requirements for SENCs and ENCs. The second quiz also matches column A concepts to column B explanations or standards. It addresses presentation size for backup ECDIS, ECDIS display chart representation size, mandatory ECDIS inputs, and indications of overscale or underscale on ECDIS.
This document contains two matching quizzes about electronic chart display and information system (ECDIS) concepts. The first quiz matches theories in column A to proponents in column B. It covers topics like what the question mark represents on an ENC chart, IMO requirements for updating ECDIS, display modes, and requirements for SENCs and ENCs. The second quiz also matches column A concepts to column B explanations or standards. It addresses presentation size for backup ECDIS, ECDIS display chart representation size, mandatory ECDIS inputs, and indications of overscale or underscale on ECDIS.
Matching the theories in Column "A" with their proponents in Column "B". Write only the "letter" of the correct answer on the blank provided: Column "A" Column "B" 1)____ What does the "?" represent on an ENC chart? A. ECDIS should be able to add, delete and change positions of waypoints 2)____ What is the IMO requirement for updating ECDIS? B. Should be adequate and up to date for intended voyage 3)____ What are the IMO display modes for ECDIS? C. Mean Sea Level 4)____ What are the requirements of SENCs? D. World Geodetic System 5)____ What is the vertical datum for ECDIS? E. Static and Dynamic 6)____ What is the primary function of ECDIS? F. 4500 slots available, Min is 2000 7)____ What does SOLAS Chapter 5 - Regualtion 27 cover? G. Horizontal Dilution of Position 8)____ What is HDOP? H. To contribute to safe navigation 9)____ What is an ENC? I. Nautical Charts and Publication requirements 10)___ What does ECDIS stand for? J. Electronic Navigation Chart (vector) 11)___ What is the scale of general charts? K. Automatic Indentification Sysytem 12)___ What is Special Pub. No. s-52? L. Electronic Chart Display and Information System 13)___ What are the 2 categories of MIO? M. System Raster Navigation Chart - once loaded into ECDIS system 14)___ What is a SENC? N. Base, Standard, All Other, User function 15)___ What is an SRNC? O. Position Dilution of Precision 16)___ What is PDOP? P. Should facilitate simple and reliable updating of ENC's 17)___ What does WGS stand for? Q. <1:500,000 18)___ What is AIS? R. A database in the manufacturer's internal ECDIS format, resulting in 19)___ What are the required waypoint capbilities in lossless trnasforamtion of entire ENC content and updates. Database is ECDIS? accessed by ECDIS for the display generation. SENC may include info 20)___ How many time slots available by AIS system? added by user or other source. What is minimum? S. Objects that are insufficiently attributed, or incorrectly attributed or if there is an error compiling at hydrographic office T. Specification for chart content and display aspects of ECDIS Midterm Quiz 2 Matching the theories in Column "A" with their proponents in Column "B". Write only the "letter" of the correct answer on the blank provided: Column "A" Column "B" 1)_____ Presentation size for back up ECDIS A. 4 LOPS 2)_____ In accordance with IMO Performance Standard B. Raster Navigation Chart Requirments for ECDIS, what is the size of the display C. Should indicate over-scale or under-scale chart representation area? D. Nautical Charts and Publication requirements 3)_____ What are the 2 classes of Electronic Chart Display System? E. Mean lower low water 4)_____ How many LOPS can you have in ECDIS? F. Hydrographic services 5)_____ What does the default safety contour default in ECDIS? G. 1. ECDIS (meets IMO/SOLAS chart reqts) 6)_____ What does SOLAS Chapter 5 Regulation 18 cover? 2. ECS - used to aid navigation but doesn't meet reqs. 7)_____ What is a RNC? H. Must be able to display in North Up but others are allowed such 8)_____ What are the 3 mandatory inputs required for ECDIS? as heads up and course up 9)_____ What type of chart projection does ECDIS use? I. 250mm by 250mm or 250mm diameter 10)____ What ECDIS requirements with respect to scaling? J. Distributed on authority of government authorities Hydrographic 11)____ What does SOLAS Chapter 5 - Regulation 9 cover? Offices 12)____ What IMO display level cannot be changed? K. Magenta frame aound area for which larger scale is available 13)____ What does SOLAS Chapter 5 - Regulation 27 cover? L. Vertical black or grey lines in that area 14)____ NMEA stands for? M. 4500 slots available, Min is 2000 15)____ What is an indication of Underscale or SCMAX? N. National Marine Electronics Association 16)____ What is the mandatory directional display mode in ECDIS? O. Mean Sea Level 17)____ What is the sounding datum for ECDIS? P. 30 metres 18)____ Where must charts for ECDIS come from? Q. Position (GPS)< Speed Log, and Gyro 19)____ What is an indication of overscale of SCAMIN? R. Base display 20)____ What is the vertical datum for ECDIS? S. Mercator T. Approval, Surveys and performance standards of navigation system and equipment and voyage recorder