Вы находитесь на странице: 1из 3

c  


 

2 p Hatch Program was touched and the 80 chlor F&T was select Then the Start button was
touched
2 p  round sample cell was filled with 20 mL of sample
3 p The content of one DPD Total Chlorine Powder Pillow was added to the sample cell
(This was a prepared sample) The sample cell was swirled for 20 seconds to mix the
content
4 p The timer icon and the Ok button were touched  three minute reaction period was
begun
5 p nother round sample cell was filled with 20 mL of sample (This was the blank) The
sample cell was wiped and it was placed into the cell holder
6 p The Zero buttons was touched and 0 00 mg/L Clº was showed in the display
7 p ÿithin three minutes after the timer was beep, the prepared sample was wiped and it was
placed into the cell holder
8 p The Read button was touched and the results were appeared in mg/L Clº





2 p Hatch Program was touched and the program 80 chlor F&T was select Then the Start
button was touched
2 p  round sample cell was filled with 20 mL of water sample (This was the blank)
3 p The blank was wiped and it was placed into the cell holder
4 p The Zero buttons was touched and 0 00 mg/L Clº was showed in the display
5 p  second round cell was filled with another 20 mL of sample
6 p The content of one DPD Free Chlorine Powder Pillow was added to the sample cell
(This was a prepared sample) The sample cell was swirled for 20 seconds to mix the
content
7 p ÿithin one minute of adding the reagent, the prepared sample was placed into the cell
holder
8 p The Read button was touched and the results were appeared in mg/L Clº
  

2 p Hatch Program was touched and the 680 sulfate was select Then the Start button was
touched
2 p  clean sample cell was filled with 20 mL of sample
3 p The content of one SulfaVer 4 Reagent Powder Pillow was added to the sample cell
(This was a prepared sample) The sample cell was swirled for 20 seconds to mix the
content
4 p The timer icon and the Ok button were touched  five minute reaction period was
begun The cells were not disturbed during this time
5 p  second sample cell was filled with 20 mL of sample (This was the blank)
6 p ÿhen the timer beeps, the blank was placed into the cell holder
7 p The Zero buttons was touched and 0 00 mg/L SO42- was showed in the display
8 p ÿithin five minutes after the timer was beep, the prepared sample was placed into the
cell holder The Read button was touched and the results were appeared in mg/L SO42-
9 p The sample cell was cleaned with soap and a brush

c 

  
   

2 p Hatch Program was touched and the program 490 P React PV was select Then the Start
button was touched
2 p  sample cell was filled with 20 mL of sample
3 p The content of one PhosVer 3 Phosphate Powder Pillow was added to the cell The cell
was cap immediately and it was inverted to mix the content (This was a prepared
sample)
4 p The timer icon and the Ok button were touched  two minute reaction period was
begun If the sample was digested using the cid Persulfate digestion, a ten minute
reaction period was required
5 p nother sample cell was filled with 20 mL of sample (This was the blank)
6 p ÿhen the timer beeps, the blank was wiped and it was placed into the cell holder
7 p The Zero buttons was touched and 0 00 mg/L PO43- was showed in the display
8 p The prepared sample was wiped and it was placed into the cell holder The Read button
was touched and the results were appeared in mg/L PO43-

   

2 p Hatch Program was touched and the program 90 Chromium, Hex was select Then the
Start button was touched
2 p  round sample cell was filled with 20 mL of sample
3 p The content of one ChromaVer 3 Reagent Powder Pillow was added to the sample cell
(This was the prepared sample) The cell was cap immediately and it was inverted to mix
the content If hexavalent chromium was present, a purple colour was formed
4 p The timer icon and the Ok button were touched  five minute reaction period was
begun
5 p nother round sample cell was filled with 20 mL of sample (This was the blank)
6 p ÿhen the timer beeps, the blank was placed into the cell holder
7 p The Zero buttons was touched and 0 00 mg/L Cr6+ was showed in the display
9 p The prepared sample was placed into the cell holder The Read button was touched and
the results were appeared in mg/L Cr6+

r
 

2 p Hatch Program was touched and the program 265 Iron, FerraVer was select Then the
Start button was touched
2 p  clean, round sample cell was filled with 20 mL of sample
3 p The content of one FerraVerIron 3 Reagent Powder Pillow was added to the sample cell
(This was the prepared sample) The cell was swirled to mix the content
4 p The timer icon and the Ok button were touched  three minute reaction period was
begun (Samples that contain rust should react for at least 5 minutes)
5 p nother sample cell was filled with 20 mL of sample (This was the blank)
6 p ÿhen the timer beeps, the blank was placed into the cell holder
7 p The Zero buttons was touched and 0 00 mg/L Fe was showed in the display
8 p The prepared sample was placed into the cell holder The Read button was touched and
the results were appeared in mg/L Fe

Вам также может понравиться