ͤ For details of specifications, outline drawings, or model code numbers, go to the Shinkawa Sensor Technology website (http://www.sst-shinkawa.co.jp).
VM-75□B VM-741B VM-742B VM-701B VM-704B VM-721B
Power Supply Module Local Communication & Network Vibration/Displacement Temperature Monitor 18-Channel Relay
Phase Marker Module Communication Module Monitor Module Module Module
ۑVM-76ڧB Instrument Rack analysis data (0.5X, 1X, 2X, Not-1X)*3 Six alarm relays are available for
6U, 19 in. and alarm status are output via each monitor module.
482.6 (W) x 265.9 (H) x 350 (D) mm Ethernet using Modbus/TCP If the optional analysis board is
VM-761B – Features European protocol or RS-485 using installed on VM-701B or
I/O terminal type. Modbus/RTU. VM-702B, it performs analysis
VM-762B* – Features D-sub I/O
1 For the infiSYS View Station, based on the received phase
connector type. measured values, analysis data*3 marker signals (max. 4 channels
(*1 Under development) and waveform data*3 are output per rack) and vibration waveform
via dedicated Ethernet. signals (max. 44 channels per
ۑVM-75ڧB Power Supply (*3 Available with the optional analysis rack), and then transmits the
boards installed on vibration monitor analysis data to the infiSYS View
Module modules.)
Station via VM-742B.
Rated voltage types: 100-240
Note: For monitoring parameters and
VAC, 24 VDC*2 or 110 VDC ۑVM-70□B Monitor Module the number of channels of each
Up to two power supply modules Receives input signals from
can be mounted on a rack for various transducers, including ۑVM-721B 18-Channel
redundant power supply. vibration/displacement Relay Module
(*2 Under development) transducers, acceleration/velocity Provides 18 alarm contacts that
transducers, thermocouples and are independent from monitor
ۑVM-741B Local Communication
RTD, processes them according modules.
& Phase Marker Module
to the monitoring parameters, and Users can program AND/OR or 2
Transmits data from back outputs the measured values and out of 3 logics with any channels
communication port to local alarm contact. of any modules within the rack.
display PC via dedicated Ethernet
to display bar graphs of measured
values and alarm status. Monitor Module Monitoring Parameter Number Number Input Transducer
(Requires VM-771B MCL View installed of Inputs of Outputs
Network Comm.
Modbus/TCP and Modbus/RTU (Redundant Comm.)
Host PC
Dedicated Comm. Line
Local Comm.
for infiSYS View Station
Ethernet MCL View
Ethernet
Contact Input
࣭Alarm Reset
࣭Sequence
࣭Low-cut Filter (10 pole) Monitor Output (Buffered Output)
PC for Service Front BNC & Rear Panel Connector
Recorder Output
USB 4 to 20 mA or 1 to 5 V
Device Config Local Comm. Alarm Relay Output
Individual monitor modules
DAN, ALT, CH-OK
Rack as a system
SYS-OK, PWR-OK
Power Supply 1 to 2
AC or DC Transducer44 ch
Phase Marker4 ch (RD, FK) (VK, FK, CV, CA, RD, MS)
Power Supply for Transducer44 ch
ͤ For details of specifications, outline drawings, or model code numbers, go to the Shinkawa Sensor Technology website (http://www.sst-shinkawa.co.jp).
Module Item Specifications
Instrument Rack Size 482.6 (W) 265.9 (H) 350.0 (D) mm
Max. number of ࣭Power Supply Module㺃㺃㺃2 ࣭Local Communication & Phase Marker Module㺃㺃㺃1
Mountable Modules ࣭Network Communication Module㺃㺃㺃2 ࣭Monitor Module㺃㺃㺃11
࣭18-Channel Relay Module㺃㺃㺃1
* For module and mountable slot number, refer to the chart on page 6, “MOUNTABLE MODULE SLOT NUMBER”.
Power Supply Module Power (rating) 100-240 VAC / 110 VDC / 24 VDC (Module for 24 VDC is under development.)
Local Communication & Phase Marker Input RD-05A or FK-202F Transducer 4 channels
Phase Marker Module
Communication Port Front USB 1 (for PC for service and maintenance purpose)
Rear Ethernet 100 Base-TX 1 (for PC for permanent display)
Software Screen View * MCL View installation on PC required.
[Bar graph screen] Measured value (numeric and bar graph displays), GAP (bias) voltage indication,
(current value display) alarm setting value, alarm status, channel bypass status,
danger bypass status, Power OK status, tag name, serial No., channel name
[Train screen] Machine train diagram, measured value, alarm setting value
[Trend graph screen] Cursor function
[Relay status screen] Relay status, relay logic
Monitor Module Digital Display Accuracy Vibration/displacement/eccentricity s1.0% of F.S. at 25 Υ s2.0% of F.S. at 0 to 65 Υ
(on Display Software Rotation speed s(0.003% of rdg. 㸩1 digit) at 25 Υ s(0.03% of rdg. 㸩1 digit) at 0 to 65 Υ
for PC) Temperature s(1.0% of F.S. 㸩1Υ) at 25 Υ s(2.0% of F.S. 㸩1Υ) at 0 to 65 Υ
Vibration Analysis Number of points of vibration analysis Up to 44 points* (vibration channels of VM-701B)
Capability * When 11 modules are installed.
(Available with analysis Analysis item Amplitude : 0.5X, 1X, 2X, nX1*, nX2*, nX3*, nX4*, Not-1X, Sp-p max
board installed) Phase : 0.5X, 1X, 2X, nX1*, nX2*, nX3*, nX4*
* nX amplitude and phase can be monitored on the infiSYS View Station.
Network Communication Protocol Modbus/TCP Ethernet 10 Base-T / 100 Base-TX (communication ports at rear side)
Communication Module Modbus/RTU RS-485
Communication Item ・Measured value ・Gap voltage ・Danger alarm status ・Alert alarm status ・OK alarm status
・Danger Bypass status ・Danger & Alert Set value ・OK limits set value
・Alarm set multiplier status ・Low-cut filter (10 pole) ON/OFF status ・Power-OK status
・Analysis data (available with analysis board installed): amplitude and phase of 0.5X, 1X and 2X and amplitude of
Not-1X
Dimension : mm
s
3
d Up to 4 VM-76□B instrument racks can be connected to local PC. (MCL View software installation is required.)
PC for Local Display
MCL view
HUB
LAN cable
VM-7B
AC AC
AC AC
AC AC
AC AC
Slot No. P1 C1 0 1 2 3 4 5 6 7 8 9 10 11
P2 C2
3RZHU6XSSO\ 0RQLWRU0RGXOH
0RGXOH /RFDO&RPPXQLFDWLRQ 3KDVH0DUNHU0RGXOH
1HWZRUN&RPPXQLFDWLRQ0RGXOH &KDQQHO5HOD\0RGXOH
Slot No.
Module
P1 P2 C1 C2 0 1 2 3 4 5 6 7 8 9 10 11
VM-75ڧ1B Power Supply Module (primary) ۑ
VM-75ڧ2B Power Supply Module (secondary) ۑ
VM-742B Network Communication Module ۑ ۑ
VM-741B Local Communication&Phase
ۑ
Marker Module
VM-701B Vibration/Displacement Monitor
ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
Module
VM-702B Absolute Vibration Monitor Module ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
VM-703B Tachometer&Eccentricity Monitor
ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
Module
VM-704B Temperature Monitor Module ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
VM-706B Rod Drop Monitor Module ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
VM-721B 18-Channel Relay Module ۑ
VZ-71 30mm (W) Blank Panel Ѹ *1 ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ ۑ
VZ-75 20mm (W) Blank Panel ۑ ۑ
VZ-76 50mm (W) Blank Panel Ѹ *2 ۑ
*1 ) Local Communication & Phase Marker Module is installed in slot 0 with any rack design.
*2 ) Primary power supply is installed in slot P1.
ͤ For details of specifications, outline drawings, or model code numbers, go to the Shinkawa Sensor Technology website (http://www.sst-shinkawa.co.jp).
ͤ When exporting Shinkawa products, permission may be required for export or service
transactions, pursuant to the provision of the Foreign Exchange and Foreign Trade Act.
When re-exporting Shinkawa products, permission may be required from the US Department of
Commerce, pursuant to the provision of the Export Administration Regulation (EAR).
Please contact our service representative for further information.
ͤ All company and product names in this brochure are trademarks or registered trademarks.
Published in Jul. 2011
Contact to