Академический Документы
Профессиональный Документы
Культура Документы
到臂架侧时,302 号线有电。
302: The anode of remote control power supply. When choosing remote control
6:遥控器电源的负极。与电控柜内的接地线相连接。
6: The cathode of remote control power supply, connecting to the ground in the
electric cabinet.
NA、NB、REL4:遥控器内部开关,当遥控器的发射器开启后,这两个开关闭合。
NA 、 NB 、 REL4 : internal switch in the remote control, which close when the
emitter opened.
101:操作顺回转时,101 号线有电流输出,控制顺回转动作,臂架动作的快慢由电流的
大小决定。
101:When operation clockwise slewing, the 101 wire should be current output
102:操作逆回转时,102 号线有电流输出,控制逆回转动作。
103:操作一臂上时,103 号线有电流输出,控制一臂上动作。
103: When operation the first section boom to up, the 103 wire should be a
104:操作一臂下时,104 号线有电流输出,控制一臂下动作。
104: When operation the first section boom to down, the 104 wire should be
105:操作二臂上时,105 号线有电流输出,控制二臂上动作。
105: when operation the second section boom up, the 105 wire should be
106:操作二臂下时,106 号线有电流输出,控制二臂下动作。
106: when operation the second section boom down, the 106 wire should be
107:操作三臂上时,107 号线有电流输出,控制三臂上动作。
107: when operation the third section boom up, the 107 wire should be current
108:操作三臂下时,108 号线有电流输出,控制三臂下动作。
108: when operation the third section boom down, the 108 wire should be
109:操作四臂上时,109 号线有电流输出,控制四臂上动作。
109: when operation the 4th.section boom up, the 109 wire should be current
110:操作四臂下时,110 号线有电流输出,控制四臂下动作。
110: when operation the 4th.section boom down, the 110 wire should be current
111:操作五臂上时,111 号线有电流输出,控制五臂上动作。
111: when operation 5th.section boom up, the 111 wire should be current output
112:操作五臂下时,112 号线有电流输出,控制五臂下动作。
112: when operation 5th.section boom down, the wire 112 should be current
113: when operation every movement of boom, the 113 wire should be 24V
current output to control the solenoid controlled relief valve of the multiplex
valve
21: when use the remote control to operation normal pumping, the 21 wire
22: when use the remote control to operation reverse pumping, the 22 wire
23: when use the remote control to acceleration of the engine, the wire 23
24: when use the remote control to deceleration of the engine, the wire 24
29: when use the remote control to adjust the switch of the main pump
52: when use the remote control to stop the engine, the wire 52 should be
SA0: the master switch of the power supply, when it close up, should be
connected the battery, when it turn off, should be cut off power supply from the
battery.
95:冷却风机的总电源。
1:电控系统其他元器件的总电源。
12(QF3):看料灯、工作灯电源。
12(QF3): the power supply for the hopper lamp, working light
11:电笛电源。
2(KA1):上装控制系统总电源继电器。
3:控制器、触摸屏电源。
3: the power supply for the controller and the touch screen.
。
4:面/遥转换开关转换到遥控侧后的电源(支腿、臂架电源)
10:面控电源。
5:泵送系统、润滑系统、清洗系统电源。
5: the power supply for the pumping system, lubrication system, cleaning
system
11A:滤芯系统电源。
16A:振动电机电源。
KA3:冷却风扇继电器,
SA6:冷却风扇选择开关。
第三页 作业控制系统 1
Page 3 operational control system 1
一、 主控制器输入信号:
一. the master controller input signal
60:由底盘引来的油泵转速信号线。
60: the signal of oil pump rotate speed from the chassis
61:由底盘引来的发动机转速信号线。
90:泵送压力传感器信号线。
93:液压油温传感器信号线。
137:左油缸接近开关换向信号。
137: the changover signal for the proximity switch of left main cylinder
138:右油缸接近开关换向信号。
138: the changover signal for the proximity switch of right main cylinder
29:面控、遥控合并之后的排量档位信号(0~10V)。
29: the merged displacement signal for the panel control & remote control
(0-10v)
21:面控、遥控合并之后的正泵信号。
21: the merged normal pumping signal for the panel control & remote control
22:面控、遥控合并之后的反泵信号。
22: the merged reverse pumping signal for the panel control & remote control
23:面控、遥控合并之后的加速信号。
23: the merged acceleration signal for the panel control & remote control
24:面控、遥控合并之后的减速信号。
24: the merged deceleration signal for the panel control & remote control
25:面控的左主缸点动信号。
25: the signal for inching the left main cylinder of panel control
26:面控的右主缸点动信号。
26: the signal for inching the right main cylinder of panel control
27:面控的左摆缸点动信号。
27: the signal for inching the left swing cylinder of panel control
28:面控的右摆缸点动信号。
28: the signal for inching the right swing cylinder of panel control
二、 主控制器输出信号:
二. output signals for the master controller
45:控制排量比例电磁铁的电流信号,电流越大,阀的开度越大。
45: the signal for control the proportional solenoid valve of displacement, if the
201:控制臂架多路阀顺回转电磁铁。
201: to control the clock-wise slewing solenoid valve of the multiplex valve
202:控制臂架多路阀逆回转电磁铁。
202: to control the counter clock-wise slewing solenoid valve of the multiplex
valve.
203:控制臂架多路阀一臂上电磁铁。
203: to control the first section boom up solenoid valve of the multiplex valve.
204:控制臂架多路阀一臂下电磁铁。
204: to control the first section boom down solenoid valve of the multiplex
valve.
105:控制臂架多路阀二臂上电磁铁。
105: to control the second section boom up solenoid valve of the multiplex
valve.
106:控制臂架多路阀二臂下电磁铁。
106: to control the second section boom down solenoid valve of the multiplex
valve.
107:控制臂架多路阀三臂上电磁铁。
107: to control the third section boom up solenoid valve of the multiplex valve.
108:控制臂架多路阀三臂下电磁铁。
108: to control the third section boom down solenoid valve of the multiplex
valve.
109:控制臂架多路阀四臂上电磁铁。
109: to control the 4th. section boom up solenoid valve of the multiplex valve.
110:控制臂架多路阀四臂下电磁铁。
110: to control the 4th. section boom down solenoid valve of the multiplex
valve.
111:控制臂架多路阀五臂上电磁铁。
111: to control the 5th. section boom up solenoid valve of the multiplex valve.
112:控制臂架多路阀五臂下电磁铁。
112: to control the 5th. section boom down solenoid valve of the multiplex
valve.
121:当有顺回转限位输出时,121 号线得电。
121: when output signal for clock-wise slewing limited, the 121 wire should be
power on
122:当有逆回转限位输出时,122 号线得电。
122:when output signal for counter clock-wise slewing limited, the 122 wire
66:控制臂架多路阀电子锁死电磁铁。
三、 搅拌控制线路:
67: the power supply for mixing solenoid valve. When the grating covered, the
67 wire should be power on, when the grating opened, the 67 wire should be go
off power.
48:控制反搅拌电磁铁。
49:控制正搅拌电磁铁。
一、 从控制器输入信号:
一.The auxiliary controller input signal
135:编码器通道 A 信号线,接自臂架减速机上的回转编码器。
135:the signal A wire for the rotate encode, connected by the encode top of the
reducer
136:编码器通道 B 信号线,接自臂架减速机内的回转编码器。
136:the signal B wire for the rotate encode, connected by the encode top of the
reducer
215:水箱接近开关 1(靠近料斗)信号线,接自水箱接近开关。
215: the proximity switch 1 ( anear the hopper side) of the auxiliary water tank,
216:水箱接近开关 2(远离料斗)信号线,接自水箱接近开关。
216: the proximity switch 2 (anear the main cylinder side) of the auxiliary water
59:大臂在位信号线,接自大臂接近开关。
59: the wire of the first boom on side signal, connected by the proximity switch
119:急停熄火信号线,接自各急停按钮。
119: the wire of emergency stop signal, connected by each of emergency stop
button
57:超压搅拌反转信号线,接自搅拌超压传感器。
57: the wire of the over pressure reverse mixing signal, connected by the
pressure sensor.
58:液位低信号线,接自液位低传感器。
58: the wire of low liquid level signal, connected by the hydraulic oil level sensor
33:高低压切换信号,接自臂架支撑架处的高低压切换开关。
33: the signal of high-low pressure changeover, connected by the switch of the
70: the signal of the transfer box working condition, if 70 power on so the
transfer box normal working, if 70 power off so the transfer box failure; when
30:冷却马达自动工作信号。
225:支撑方式选择上之后与地连通。
225:the signal for connect the negative pole after chose the support mode
220:凸轮开关全支撑信号。
221:凸轮开关左支撑信号。
222:凸轮开关右支撑信号。
223:凸轮开关前支撑信号。
127:支撑方式确认键输入信号。
65:倒档信号。
66:支腿/臂架信号,操作支撑或者臂架时 66 号线得电。
54:声光报警器报警信号。
150:搅拌方向改变信号,当有搅拌超压信号时,该点有输出。
150: mixing changeover signal, when mixing over pressure, should be output
51:风机启动时该点有输出,继电器动作。
46:高压泵送时该点有输出。
56:低压泵送时该点有输出。
128:选择支撑模式后该点有输出。
217:泄油阀。
218:补油阀。
47:润滑。
53:电笛。
37:加速。
38:减速。
38:deceleration signal
55:风机叶子转速的控制。
41:左主缸阀。
42:右主缸阀。
43:左摆缸阀。
44:右摆缸阀。
151: press the button on the booms support, this point power on, see the
152:该点有电压时,分配卸荷阀得电。
CAN1)
310:CAN_H
309:CAN_L
CAN2)
301:CAN_H
311:CAN_L
305:CAN_H
306:CAN_L
303:CAN_H
304:CAN_L
其中 2、3、4 点根据客户的功能需要来决定是否需要接这几根线。
There into: 2,3,4 points connect according by the customer functions require
二、RS232 通讯:
二.RS232 communication
1、触摸屏通讯插头的第 2 脚与主控制器的 RS232 通道的 TxD 相连。
1. The second pin of the touch screen communication plug connecting the TxD
2. The third pin of the touch screen communication plug connecting the RxD pin
3、触摸屏通讯插头的第 5 脚与地线相连。
3. The 5th. pin of the touch screen communication plug connecting the GND
4. inside the communication plug, 4th. Pin connected 6th. Pin,7th.pin connected
8th.pin
第六页 上装控制系统
Page 6 boom kit control system
59:当大臂在位时,接近开关 SQ1 的黑色线会发生一个负信号。
59: when the first section boom on side, output a negative signal from the
116:支腿电源。
201:臂架多路阀插头顺回转电磁铁。
201: Boom Multi valve plug clock wise slewing electric magnetic metal.
202:臂架多路阀插头逆回转电磁铁。
202:Boom multi valve plug counter clockwise slewing electric magnetic metal.
203:臂架多路阀插头一臂上电磁铁。
203:Boom multi valve plug first section upward movement electric magnetic
metal.
204:臂架多路阀插头一臂下电磁铁。
204:Boom multi valve plug first section downward movement electric magnetic
metal.
105:臂架多路阀插头二臂上电磁铁。
105:Boom multi valve plug second section upward movement electric magnetic
metal.
106:臂架多路阀插头二臂下电磁铁。
106 : Boom multi valve plug second section downward movement electric
magnetic metal.
107:臂架多路阀插头三臂上电磁铁。
107:Boom multi valve plug third section upward movement electric magnetic
metal.
108:臂架多路阀插头三臂下电磁铁。
108:Boom multi valve plug third section downward movement electric magnetic
metal.
109:臂架多路阀插头四臂上电磁铁。
109:Boom multi valve plug fourth section upward movement electric magnetic metal.
110:臂架多路阀插头四臂下电磁铁。
110: Boom multi valve plug fourth section downward movement electric magnetic metal.
111:臂架多路阀插头五臂上电磁铁。
111: Boom multi valve plug fifth section upward movement electric magnetic metal.
112:臂架多路阀插头五臂下电磁铁。
112: Boom multi valve plug fifth section downward movement electric magnetic metal.
66:电子锁死电磁铁,无论是操作支腿,还是操作臂架,该电磁铁必须得电,否则支腿/臂
架没有动作。
outrigger or operation boom, the magnetic metal must power on, otherwise the
114:左支腿电磁铁。
115:右支腿电磁铁。
4:面/遥转换开关转换到遥控侧后得电。
302:面/遥转换开关转换到遥控侧,并且支腿/臂架转换开关转换到臂架侧得电。
116:面/遥转换开关转换到遥控侧,并且支腿/臂架转换开关转换到支腿侧得电。
200:用遥控器操作臂架时得电。
82: the power supply from key switch turn to first gear to power on
SA:行驶/作业转换开关。
KA12、86:行驶/作业转换保护电源(必须处于空挡才能转换)。
KA9、78:行驶/作业转换作业侧自保功能。
KA10、78:行驶/作业转换行驶侧互锁功能。
KA10、79:行驶/作业转换行驶侧自保功能。
KA9、79:行驶/作业转换作业侧互锁功能。
S1、83:分动箱双取力行程开关作业侧行程开关。
S2、89:分动箱双取力行程开关行驶侧行程开关。
KA11、89:防止分动箱故障,作业时如果得电则认为分动箱故障。
KA11.89: avoid transfer box failure, if working position power on, so transfer
box failure.
HL17:行驶指示灯。
HL15、83:作业指示灯
70:成功转换到作业侧时得电。
188: after changed drive/PTO switch to PTO side, than put into gear, power on
88:成功转换到作业侧,挂档后得电。
88: after changed to PTO side, than put into gear, power on
77:大臂在位指示灯。
以下信号由底盘公司提供:
KA21:作业时切断里程表。
71:速度传感器(接至底盘里程表)的电源正(+5V)。
。
72:速度传感器(接至底盘里程表)的电源负(GND)
73,75:速度传感器(接至底盘里程表)的脉冲信号线通道 A。
73, 75: speed sensor (connected to chassis odometer) pulse signal channel A
74、76:速度传感器(接至底盘里程表)的脉冲信号线通道 B。
74, 76: speed sensor (connected to chassis odometer) pulse signal channel B
60:油泵转速信号线。
63、64:停发动机信号。
37:加速信号。
37:acceleration signal
38:减速信号。
61:发动机转速信号。
65:倒档。
65: reverse gear
87:空挡。