00 Modification factor for anchor groups loaded eccentrically in tension
Modification factor for edge effects for single anchor or anchor
Ψed,N 0.85 groups loaded in tension Ψc,N 1 *Assuming that analysis indicates cracking at service load level Modification factor for post-installed anchors Ψcp,N 1 kc,1 10 kc,2 3.9
Basic concrete breakout strength Nb 141 kN
Nominal concrete breakout strength for group of anchors Ncbg 90 kN
Design concrete breakout strength for group of anchors ΦaNcbg 63 kN Check ratio (Ftmax,g/Φ*Ncbg) 0.71 < 1 OK
Design concrete breakout strength for single anchor ΦaNcb 63 kN
Check ratio (Ftmax/Φ*Ncb) 0.71 < 1 OK 2) Pullout Strength of Anchor In Tension One side of anchor head ah 50 mm
Bearing area of head of anchor Abrg 292 mm2 2299
Pullout strength of a single anchor in tension Np 58 kN
Ψcp 1 Design pullout strength of a single anchor in tension ΦNp 41 kN Check ratio (Ftmax/Φ*Np) 1.10 > 1 NOT OK Design pullout strength of a group of anchors in tension ΦNpg 82 kN Check ratio (Ftmax,g/Φ*Npg) 0.55 < 1 OK 3) Concrete Side-Face Blowout Strength of Anchor In Tension Factor f 0.75 Nominal side-face blowout strength for single anchor Nsb NO NEED TO CHECK Nominal side-face blowout strength for group of anchors Nsbg NO NEED TO CHECK
C) SHEAR FAILURE CHECKS
1) Steel Check Strength reduction factor Φv 0.65 Nominal strength of single anchor in shear Vsa 47 kN Design strength of single anchor in shear ΦvVsa 30 kN Nominal strength of group of anchors in shear Vsg 93 kN Design strength of group of anchors in shear ΦvVsg 60 kN Shear demand for group of anchors Vzmax 11 kN Shear demand for a single anchor Vzmax,a 11 kN Check ratio (Vzmax/Φ*Vsg) 0.18 < 1 OK 2) Concrete Check 1) Concrete Breakout Strength of Anchor In Shear Φv 0.7