Ψec,N 1.

00
Modification factor for anchor groups loaded eccentrically in tension

Modification factor for edge effects for single anchor or anchor


Ψed,N 0.85
groups loaded in tension
Ψc,N 1
*Assuming that analysis indicates cracking at service load level
Modification factor for post-installed anchors Ψcp,N 1
kc,1 10
kc,2 3.9

Basic concrete breakout strength Nb 141 kN

Nominal concrete breakout strength for group of anchors Ncbg 90 kN


Design concrete breakout strength for group of anchors ΦaNcbg 63 kN
Check ratio (Ftmax,g/Φ*Ncbg) 0.71 < 1 OK

Design concrete breakout strength for single anchor ΦaNcb 63 kN


Check ratio (Ftmax/Φ*Ncb) 0.71 < 1 OK
2) Pullout Strength of Anchor In Tension
One side of anchor head ah 50 mm

Bearing area of head of anchor Abrg 292 mm2 2299

Pullout strength of a single anchor in tension Np 58 kN


Ψcp 1
Design pullout strength of a single anchor in tension ΦNp 41 kN
Check ratio (Ftmax/Φ*Np) 1.10 > 1 NOT OK
Design pullout strength of a group of anchors in tension ΦNpg 82 kN
Check ratio (Ftmax,g/Φ*Npg) 0.55 < 1 OK
3) Concrete Side-Face Blowout Strength of Anchor In Tension
Factor f 0.75
Nominal side-face blowout strength for single anchor Nsb NO NEED TO CHECK
Nominal side-face blowout strength for group of anchors Nsbg NO NEED TO CHECK

C) SHEAR FAILURE CHECKS


1) Steel Check
Strength reduction factor Φv 0.65
Nominal strength of single anchor in shear Vsa 47 kN
Design strength of single anchor in shear ΦvVsa 30 kN
Nominal strength of group of anchors in shear Vsg 93 kN
Design strength of group of anchors in shear ΦvVsg 60 kN
Shear demand for group of anchors Vzmax 11 kN
Shear demand for a single anchor Vzmax,a 11 kN
Check ratio (Vzmax/Φ*Vsg) 0.18 < 1 OK
2) Concrete Check
1) Concrete Breakout Strength of Anchor In Shear
Φv 0.7