Вы находитесь на странице: 1из 93

Управление

Гидроприводом

2007
DIRECTIONAL CONTROL VALVES
CONTENTS
A range of cartridge solenoid valves with flows up to 100 litres/min (26 US GPM) and pressures up to
350 bar (5000 psi), including a variety of poppet and spool solutions.
SELECTION

CIRCUIT SERIES APPLICATION RANGE PAGE


S201 N.O. 2-way, 2-position poppet 210 bar (3000 psi); 30 litres/min (8 US GPM) 11-1111
S501 N.O. 2-way, 2-position poppet 210 bar (3000 psi); 60 litres/min (16 US GPM) 11-1211
S701 N.O. 2-way, 2-position poppet 210 bar (3000 psi); 80 litres/min (20 US GPM) 11-1255
S901 N.O. 2-way, 2-position poppet 250 bar (3600 psi); 160 litres/min (42 US GPM) 11-1275
S202 N.C. 2-way, 2-position poppet 210 bar (3000 psi); 30 litres/min (8 US GPM) 11-1111
S502 N.C. 2-way, 2-position poppet 210 bar (3000 psi); 60 litres/min (16 US GPM) 11-1211
S702 N.C. 2-way, 2-position poppet 210 bar (3000 psi); 80 litres/min (20 US GPM) 11-1255
S902 N.C. 2-way, 2-position poppet 250 bar (3600 psi); 160 litres/min (42 US GPM) 11-1275
S600 N.O. 2-way, 2-position poppet 250 bar (3600 psi); 100 litres/min (26 US GPM) 11-1311
S609 N.C. 2-way, 2-position poppet 250 bar (3600 psi); 100 litres/min (26 US GPM) 11-1311
7SP300 N.O. 2-way, 2-position poppet 210 bar (3000 psi); 300 litres/min (80 US GPM) 11-1351
7SP300 N.C. 2-way, 2-position poppet 210 bar (3000 psi); 300 litres/min (80 US GPM) 11-1351
SX203 N.O. 2-way, 2-position poppet 280 bar (4000 psi); 20 litres/min (5 US GPM) 11-1431
SX204 N.C. 2-way, 2-position poppet 350 bar (5000 psi); 20 litres/min (5 US GPM) 11-1431

S205 N.O. 2-way, 2-position poppet 210 bar (3000 psi); 1 litre/min (0.25 US GPM) 11-1611
S206 N.C. 2-way, 2-position poppet 210 bar (3000 psi); 1 litre/min (0.25 US GPM) 11-1611

11 S207
S607
N.O. 2-way, 2-position poppet
N.O. 2-way, 2-position poppet
350 bar (5000 psi); 1 litre/min (0.25 US GPM)
250 bar (3600 psi); 100 litres/min (26 US GPM)
11-1711
11-1811
S608 N.C. 2-way, 2-position poppet 250 bar (3600 psi); 100 litres/min (26 US GPM) 11-1811
S210 N.O. 2-way, 2-position spool 210 bar (3000 psi); 20 litres/min (5 US GPM) 11-1911
S510(H) N.O. 2-way, 2-position spool 210 bar (3000 psi); 25 litres/min (6.5 US GPM) 11-2011
S211 N.C. 2-way, 2-position spool 210 bar (3000 psi); 20 litres/min (5 US GPM) 11-1911
S511(H) N.C. 2-way, 2-position spool 210 bar (3000 psi); 25 litres/min (6.5 US GPM) 11-2011
S612 N.O. 2-way, 2-position spool 250 bar (3600 psi); 100 litres/min (26 US GPM) 11-1811
S613 N.C. 2-way, 2-position spool 250 bar (3600 psi); 100 litres/min (26 US GPM) 11-1811
S215 N.C. 2-way, 2 position poppet 210 bar (3000 psi); 1 litre/min (0.26 US GPM) 11-2051
S217(H) N.C. 2-way, 2 position poppet 210 bar (3000 psi); 20 litres/min (5 US GPM) 11-2071
S217A N.C. 2-way, 2 position poppet 210 bar (3000 psi); 10 litres/min (2.6 US GPM) 11-2073
S717 N.C. 2-way, 2 position poppet 350 bar (5000 psi); 90 litres/min (24 US GPM) 11-2091
S716 N.O. 2-way, 2 position poppet 350 bar (5000 psi); 90 litres/min (24 US GPM) 11-2091
S220(H) 3-way, 2-position spool 210 bar (3000 psi); 14 litres/min (3.7 US GPM) 11-2111
S520(H) 3-way, 2-position spool 210 bar (3000 psi); 40 litres/min (10 US GPM) 11-2211
S221(H) 3-way, 2-position spool 210 bar (3000 psi); 20 litres/min (5 US GPM) 11-2311
S521(H) 3-way, 2-position spool 210 bar (3000 psi); 44 litres/min (11.5 US GPM) 11-2411

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1011.C
CIRCUIT SERIES APPLICATION RANGE PAGE

S222 3-way, 2-position spool 100 bar (1500 psi); 20 litres/min (5 US GPM) 11-2511
S228 3-way, 2-position spool 50 bar (750 psi); 15 litres/min (4 US GPM) 11-2721
S229 3-way, 2-position poppet 210 bar (3000 psi); 12 litres/min (3 US GPM) 11-2731
S525(H) 3-way, 2-position spool 210 bar (3000 psi); 30 litres/min (8 US GPM) 11-2611

S526 3-way, 2-position spool 210 bar (3000 psi); 35 litres/min (9 US GPM) 11-2711

S240 4-way, 2-position spool 210 bar (3000 psi); 18 litres/min (4.7 US GPM) 11-2811
S241 4-way, 2-position spool 210 bar (3000 psi); 20 litres/min (5 US GPM) 11-2911
S541 4-way, 2-position spool 210 bar (3000 psi); 30 litres/min (8 US GPM) 11-3011
S242(H) 4-way, 2-position spool 210 bar (3000 psi); 15 litres/min (4 US GPM) 11-3111
S542 4-way, 2-position spool 210 bar (3000 psi); 35 litres/min (9 US GPM) 11-3211
S270 4-way, 3-position spool 210 bar (3000 psi); 13 litres/min (3.5 US GPM) 11-3311
S570 4-way, 3-position spool 210 bar (3000 psi); 35 litres/min (9 US GPM) 11-3411
S271 4-way, 3-position spool 210 bar (3000 psi); 14 litres/min (3.7 US GPM) 11-3511
S571 4-way, 3-position spool 210 bar (3000 psi); 34 litres/min (8.7 US GPM) 11-3611
S272 4-way, 3-position spool 210 bar (3000 psi); 14 litres/min (3.7 US GPM) 11-3711
S572 4-way, 3-position spool 210 bar (3000 psi); 34 litres/min (8.7 US GPM) 11-3811
S274 4-way, 3-position spool 210 bar (3000 psi); 14 litres/min (3.7 US GPM) 11-3911
S574 4-way, 3-position spool 210 bar (3000 psi); 34 litres/min (8.7 US GPM) 11-4011
S277 4-way, 3-position spool 210 bar (3000 psi); 11.5 litres/min (3.1 US GPM) 11-4111
S577R 4-way, 3-position spool 210 bar (3000 psi); 27 litres/min (7 US GPM) 11-4211
PDR21A Proportional Pressure relief 350 bar (5000 psi) 1.5 litres/min (0.3 US GPM) 11/2-151

PPD22A(H) Proportional Pressure reducer 210 bar (3000 psi); 20 litres/min (5.4 US GPM) 11/5-105 11
PFR24A Proportional Flow Control 210 bar (3000 psi); 18 litres/min (4.7 US GPM) 11/9-121

Note. When using these valves in conjunction with a PLC and there is a possibility of a residual voltage please
contact the factory with application information to ensure safe operation of the product.

TYPICAL CIRCUIT EXAMPLES

S206

S202 S571

RELIEF VENTED SYSTEM SELECTION MULTIPLE ACTUATOR SELECTION

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1012.C
COIL INFORMATION

C13 and C16 Series


DUTY RATING
The coil is rated for continuous operation at nominal voltage
Electrical +/- 10% and a ambient range of -20 to +40.
Connection
Note. Coil performance, force produced and power
Bobbin comsumed, is effected by the heat of the coil,
Encapsulation performance figures given in this catalogue are
measured under simulated continuous duty conditions
Copper Winding at the coil stabilised temperature. It is important to
verify the actual conditions the valve will experience for
Iron Frame/Yoke any given application it should be tested in situ to
Location of “O” ring seal confirm valve selection.
between coil and tube. WIRE INSULATION
WATTAGE The coil winding is copper magnet wire insulation
equivalent to class N (200°C).
C13 (for 13 mm tubes) = 14, 22 & 27 Watts
C16 (for 16 mm tubes) = 19 & 29 Watts ENCAPSULATION MATERIAL
VOLTAGES C13, 14 Watt coils and C16, 19 Watt coils are black in
colour and made from PBT (Black Polybutylene Rein-
Standard forced) equivalent to Class F (155°C)
12 VDC 110 VRAC
24 VDC 220 VRAC C13, 22 & 27 Watt coils and C16, 29 Watt coils are
black in colour and made from IXEF (Black
Special/Optional Polyarylamide Reninforced) equivalent to Class H
Other Voltages are available on request (180°C)

ALTERNATING CURRENT INGRESS PROTECTION (IP) BS EN 60529


The coil/tube joint is sealed by “O” rings preventing fluid
For AC voltage an ISO4400 rectified connector must
11 be used, as the coils are wound for DC.
The correct connector is available from the factory:
ingress and the possibility of tube corrosion.

Different electrical connectors offer different levels of


protection the minimum being the DIN 43650 connector
110 VAC = AXP9997-115
with a gasket at IP65. Integrated Hydraulics offer a wide
220 VAC = AXP9997-230
range of connector types - details of which are available
VDR is fitted for over-voltage protection. on request.
Diodes are rated at 1.5 amp.
CONNECTORS
+
H = ISO4400 Standard DIN43650
2 pin and earth
F = Black Flying Leads 1.5mm2 wire
600 mm long, 15 AWG, 2.2 mm diameter,
AC DC COIL
Teflon FEP covered (DC voltage only)
DM = Deutsch Moulded 2 way DT04-2P series.
(DC voltage only).
- Caution – When handling coils after or during use they
maybe hot which can cause burning to the skin. Handle
AC Voltage Connector Circuit Diagram
with care and use the appropriate equipment.

We reserve the right to change specifications without notice

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1021.B
C13 Coils C16 Coils

49.0

47.8

50.0
38,1

23.9 22.0
36.0

35.5

11

ORDERING CODE EXAMPLE

C16 H 24 19
Coil Series Wattage
13 = 13 mm tube C13 C16
16 = 16 mm tube 14 = 14 Watt 19 = 19 Watt
22 = 22 Watt 29 = 29 Watt
27 = 27 Watt
Connection
H = DIN43650 ISO Standard
F = Flying Leads (12 and 24 VDC only) Voltage
DM = Deutsch Moulded (12 and 24 VDC only) 12 = 12 VDC 110 = 110 VRAC
(Consult factory for other options) 24 = 24 VDC 220 = 220 VRAC*
*220 to 240 VAC
All AC coils must be used with a
rectifying connector:-
(AXP9997-115 or AXP9997-230)
(Other voltages available on request)

We reserve the right to change specifications without notice

11-1022.C
MANUAL OVERRIDES

S2 Series - consult factory for availability

PUSH AND TWIST MANUAL OVERRIDE


TYPE 1

ø 11.00

24.50
21.30

Nut type
dependent on
valve

NORMAL POSITION MANUALLY OPERATED


POSITION

SCREW, NORMALLY OPEN SCREW, NORMALLY CLOSED


MANUAL OVERRIDE TYPE 2 MANUAL OVERRIDE TYPE 2

ø 8.1
ø 11.00

18.70
16.20

Nut type
24.50

dependent on
20.00

valve
Nut type
dependent on
valve

11
MANUALLY OPERATED NORMAL POSITION NORMAL POSITION MANUALLY OPERATED
POSITION POSITION

PUSH MANUAL OVERRIDE TYPE 3 PUSH/PULL MANUAL OVERRIDE TYPE 4


Ø 11.00 KNOB
45.50

Push to manually Override


40.50

FLUSH 11.00 A/F HEX


2.50

Nut type 10.00 A/F HEX


dependent on
valve

Ø 20.00 NUT

PUSH TO MANUALLY OVERRIDE NORMAL PULLED OUT

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1031.A
S5 Series - consult factory for availability

PUSH AND TWIST MANUAL OVERRIDE SCREW MANUAL OVERRIDE TYPE 2


TYPE 1
ø 14.50 ø 14.50

26.50
26.50

21.00
22.30

Nut type Nut type


dependent on dependent on
valve valve

NORMAL POSITION MANUALLY OPERATED MANUALLY OPERATED NORMAL POSITION


POSITION POSITION

PUSH MANUAL OVERRIDE TYPE 3 PUSH/PULL MANUAL OVERRIDE TYPE 4

Ø 11.00 KNOB

46.50
FLUSH Push to manually Override
40.50

11.00 A/F HEX


3.50

Nut type
dependent on
valve 10.00 A/F HEX

Ø 24.00 NUT
11

PUSH TO MANUALLY OVERRIDE NORMAL PULLED OUT

S6Series - consult factory for availability

PUSH MANUAL OVERRIDE TYPE 3

FLUSH Push to manually Override


3.50

Nut type
dependent on
valve

PUSH TO MANUALLY OVERRIDE

We reserve the right to change specifications without notice

11-1032.A
S201 / S202 Directional Control Valve - 2-Way, 2-Position Poppet

30 litres/min (8 US GPM)  210 bar (3000 PSI)

S201 S202 FEATURES


NORMALLY OPEN NORMALLY CLOSED
 High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.

1  Oil immersed armature solenoid.


 Various coil terminals and voltages.
2  Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
 Reversible coil without affecting performance.
COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/14 SPECIFICATIONS


Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S201 (N.O.) S202 (N.C.)
2 2
* AC coils must be used with a rectifying connector. Symbol
1 1

Max. Working Pressure 210 bar (3000 psi)


PRESSURE DROP v’s FLOW
Flow Rating 30 litres/min (8 US GPM)
Viscosity = 32 cSt (150 SSU)
Nominal flow
25 litres/min (6.5 US GPM)
S201 (Normally Open) (at Delta P = 5 bar (70 psi))

0.6 ml/min (10 dpm)


11 18 1.3 2.6
FLOW (US GPM)
3.9 5.2 6.5 7.8 9.1 10.4
260
Internal Leakage
210 bar differential at 32 centistokes

15 210 Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE (BAR)

PRESSURE (PSI)

12 175 Nominal Viscosity Range 15 to 250 centistokes


1-2 Energised
9 130 Recommended Filtration BS5540/4 18/13 (25 micron or better)
90
6 Compatible with most general
Fluid
3 45 purpose hydraulic fluids
1-2 De-energised
2-1 De-energised 0 Seal Material Standard nitrile with PTFE back up rings
0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) Seal Kit Number SK1043 (Nitrile) SK1043V (Viton)

S202 (Normally Closed) Mounting Position Unrestricted


FLOW (US GPM) Cartridge Weight 0.125 kg (0.28 lbs)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
15 210 Coil Weight 0.2 kg (0.4 lbs)
1
175 Cavity Number A879 (See page 11-441)
PRESSURE (BAR)

PRESSURE (PSI)

9 130
Torque into Cavity 20 Nm (15 lbs ft)
1-2 De-energised Electrical Data See coil data sheet
6 90
2-1 Energised Line Body Material Aluminium Alloy
1-2 Energised
3 45

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1111.A
CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS

BASIC CODE: S201 (Normally Open) BASIC CODE: S201 (Normally Open)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
50.00
48.00

23.50 36.00
59.00

38.50

2 HOLES
ø6.8 THRO'

12.80
24.00 A/F 2

50.80
8.25
27.30

3/4"-16-UNF-2A 1

22.00
2

6.00
ø12.60
15.90
16.00
6.00 31.80
19.00

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS

BASIC CODE: S202 (Normally Closed) BASIC CODE: S202 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
50.00

48.00

23.50 36.00

11
55.50

38.50

2 HOLES
ø6.8 THRO'
2
12.80

50.80

24.00 A/F
9.55

1
27.30

3/4"-16-UNF-2A
22.00

2
6.00

ø12.60 1 15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S201 N H 24 3W
Basic Code Port Sizes
S201 = (normally open) 2W = 1/4” BSP
S202 = (normally closed) 3W = 3/8” BSP 6T = 3/8” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability) Coil Termination
1 = Push and twist (S202 Only) H = DIN43650
2 = Screw (S201 & S202) F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-1112.B
S501 / S502 Directional Control Valve - 2-Way, 2-Position Poppet

60 litres/min (16 US GPM)  210 bar (3000 PSI)

S501 S502 FEATURES


NORMALLY OPEN NORMALLY CLOSED  High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.
 Various coil terminals and voltages.
2
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19

Voltage available: 12, 24 VDC SPECIFICATIONS


110, 220 VAC*
Basic Model Code S501 (N.O.) S502 (N.C.)
* AC coils must be used with a rectifying connector.
2 2
Symbol
PRESSURE DROP v’s FLOW 1 1

Viscosity = 32 cSt (150 SSU) Max. Working Pressure 210 bar (3000 psi)
Flow Rating 60 litres/min (16 US GPM)
S501 (Normally Open)
FLOW (US GPM)
Nominal Flow 60 litres/min (16 US GPM)
2.5 5 7.5 10 12.5 15
(at Delta P = 5 bar (70 psi))
15 210

11 12 175 Internal Leakage 0.6 ml/min (10 dpm)


210 bar differential at 32 centistokes
PRESSURE (BAR)

PRESSURE (PSI)

9 130
Temperature Range -20 to +120°C (-4 to +248°F)
1-2 Energised
6 90 Nominal Viscosity Range 15 to 250 centistokes

3 45
Recommended Filtration BS5540/4 18/13 (25 micron or better)
2-1 De-energised
1-2 De-energised
0 Fluid Compatible with most general
0
0 10 20 30 40 50 60 purpose hydraulic fluids
FLOW (LITRES/MIN)
Seal Material Standard nitrile with PTFE back up rings

S502 (Normally Closed) Seal Kit Number SK1028 (Nitrile) SK1028V (Viton)

FLOW (US GPM)


Mounting Position Unrestricted
2.5 5 7.5 10 12.5 15 Cartridge Weight 0.2 kg (0.4 lbs)
15 210
Coil Weight 0.3 kg (0.6 lbs)
12 175
PRESSURE (BAR)

PRESSURE (PSI)

Cavity Number A12370 (See Section 17)


9 130
1-2 De-energised Torque into Cavity 30 Nm (22 lbs ft)
6 90 Electrical Data See coil data sheet
3 45 Line Body Material Aluminium Alloy
1-2 Energised
2-1 Energised 0
0
0 10 20 30 40 50 60
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1211.A
CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS
BASIC CODE: S501 (Normally Open) BASIC CODE: S501 (Normally Open)
Body ONLY part numbers
BSP, aluminium SAE, aluminium SAE, steel
3/8” B19053
1/2” B19356 1/2” B19402 1/2” B20601
49.00 50.80
35.50
21.00
74.00

50.00

18.50
27.00 A/F

38.10
2
11.00

50.80
32.40

7/8"-14-UNF-2A
2 1
7.10

1
ø15.80
19.10 16.00

3.15 41.30 31.80

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S502 (Normally Closed) BASIC CODE: S502 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium SAE, steel
3/8” B19053
1/2” B19356 1/2” B19402 1/2” B20601
50.80
49.00
21.00 35.50
66.00

50.00

11
18.50
38.10

2
25.40 A/F
8.30

50.80
32.40

7/8"-14-UNF-2A 1
2
7.10

1 19.10 16.00
ø15.80
3.15 41.30 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S501 N H 24 3W
Basic Code Port Sizes
S501 = (normally open) 3W = 3/8” BSP
S502 = (normally closed) 4W = 1/2” BSP 8T = 1/2” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw (S501, S502) H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-1212.B
S701 / S702 Directional Control Valve - 2-Way, 2-Position Poppet

100 litres/min (26 US GPM)  210 bar (3000 PSI)

S701 S702 FEATURES


NORMALLY OPEN NORMALLY CLOSED
 High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
2
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
 Reversible coil without affecting performance.
COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19

Voltage available: 12, 24 VDC


SPECIFICATIONS
110, 220 VAC*
Basic Model Code S701 (N.O.) S702 (N.C.)
* AC coils must be used with a rectifying connector. 2 2

Symbol
1 1

PRESSURE DROP v’s FLOW Max. Pressure 210 bar (3000 psi)
Viscosity = 32 cSt (150 SSU) Flow Rating 100 litres/min (26 US GPM)

S701 (Normally Open) Nominal flow


80 litres/min (20 US GPM)
(at Delta P = 5 bar (70 psi))

11
FLOW-US GPM
0 5 10 15 20 25 30 0.6 ml/min (10 dpm)
25 Internal Leakage
210 bar differential at 32 centistokes
300
20
PRESSURE-BAR

PRESSURE-PSI

Temperature Range -20 to +120°C (-4 à +248°F)


15
200 Nominal Viscosity Range 15 to 250 centistokes
10
1-2 Energised
100
Recommended Filtration BS5540/4 18/13 (25 micron or better)
5
1-2 De-Energised
2-1 De-Energised Compatible with most general
0 Fluid
0 20 40 60 80 100 120 purpose hydraulic fluids
FLOW LITRES/MIN
Standard nitrile with PTFE back up
Seal Material
rings
S702 (Normally Closed)
Seal Kit Number SK1207(Nitrile) SK1207V (Viton)
FLOW-US GPM Mounting Position Unrestricted
0 5 10 15 20 25 30
25 Cartridge Weight 0.3 kg (0.6 lbs)
300
20 Coil Weight 0.3 kg (0.6 lbs)
PRESSURE-BAR

PRESSURE-PSI

1-2 De-Energised
15
200
Cavity Number A21473
1-2 Energised
10 Torque into Cavity 60 Nm (44 lbs ft)
100
5 Electrical Data See coil data sheet
2-1 Energised
0 Line Body Material Aluminium Alloy
0 20 40 60 80 100 120
FLOW LITRES/MIN

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1255.B
CARTRIDGE ONLY COMPLETE VALVE 3/4” PORTS

BASIC CODE: S701 (Normally Open) BASIC CODE: S701 (Normally Open)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
3/4” B22258 3/4” B22260 3/4” B22262 3/4” B22264

49.00 35.50 88.90


22.00 Ø 24.00
50.00
75.50

CT1

28.50
76.20
63.50

88.90
32.00
13.00

A/F 2
HEX
45.50

1-1/16"
-12-UN 2 1
2 HOLES
Ø10.50 THRO'
44.50 25.40
Ø 23.70 1 63.50 12.70 50.80

CARTRIDGE ONLY COMPLETE VALVE 3/4” PORTS

BASIC CODE: S702 (Normally Closed) BASIC CODE: S702 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
3/4” B22258 3/4” B22260 3/4” B22262 3/4” B22264

49.00 35.50
88.90
22.00 Ø 24.00

11
50.00
69.10

CT1
28.50
76.20
63.50

88.90

32.00 A/F
HEX 2
12.10
45.50

1-1/16"
-12-UN
2 1
2 HOLES
Ø10.50 THRO'
44.50 25.40
Ø 23.70 1 63.50 12.70 50.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S701 N H 24 6W
Basic Code Port Sizes
S701 = (normally open) 6W = 3/4” BSP 12T = 3/4” SAE
S702 = (normally closed) Voltage
Seals 12 = 12 VDC 110 = 110 VAC
N = Nitrile 24 = 24 VDC 220 = 220 VAC
V = Viton
Coil Termination
Manual Override (consult factory for availability) H = DIN43650
1 = Push and twist (S702 Only) F = Flying Leads
2 = Screw (S701 & S702) DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-1256.B
S901 / S902 Directional Control Valve
2-Way, 2-Position Poppet
160 litres/min (42 US GPM)  250bar (3600 PSI)

S901 S902 FEATURES


NORMALLY OPEN NORMALLY CLOSED  High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.

2  Standard valve bodies and common cavities.


 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5, S7 and S9 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19

Voltage available: 12, 24 VDC SPECIFICATIONS


110, 220 VAC*
Basic Model Code S901 (N.O.) S902 (N.C.)
* AC coils must be used with a rectifying connector.
2 2
Symbol
PRESSURE DROP v’s FLOW 1 1

Viscosity = 32 cSt (150 SSU) Max. Working Pressure 250 bar (3600 psi)

S901 (Normally Open) Flow Rating 160 litres/min (42 US GPM)


FLOW-US GPM
Nominal Flow
18
10 20 30 40 50 130 litres/min (34 US GPM)
250 (at Delta P = 5 bar (70 psi))
0.6 ml/min (10 dpm)
11
15
200 Internal Leakage
210 bar differential at 32 centistokes
PRESSURE-BAR

PRESSURE-PSI

12
150
Temperature Range -20 to +120°C (-4 to +248°F)
9
Nominal Viscosity Range 15 to 250 centistokes
100
6 Recommended Filtration BS5540/4 18/13 (25 micron or better)
1-2 Energised Compatible with most general
3 50 Fluid
2-1 &1-2 De-energised purpose hydraulic fluids

0 30 60 90 120 150 180 210 Seal Material Standard nitrile with PTFE back up rings
FLOW-LITRES/MIN Seal Kit Number SK1160 (Nitrile) SK1160 (Viton)
S902 (Normally Closed) Mounting Position Unrestricted
FLOW-US GPM
18
10 20 30 40 50 Cartridge Weight 0.4 kg (0.9 lbs)
250
Coil Weight 0.3 kg (0.6 lbs)
15
200
Cavity Number A21616 (See Section 17)
PRESSURE-BAR

PRESSURE-PSI

12
150
Torque into Cavity 100 Nm (74 lbs ft)
9
Electrical Data See coil data sheet
100
6 Line Body Material Aluminium Alloy (up to 210 bar*)
2-1 Energised
50
3 *For applications above 210 bar please consult our
1-2 Energised
1-2 De-energised technical department or use the steel body option.
0 30 60 90 120 150 180 210
FLOW-LITRES/MIN

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1275.B
CARTRIDGE ONLY COMPLETE VALVE 3/4” 1” PORTS
BASIC CODE: S901 (Normally Open) BASIC CODE: S901 (Normally Open)
Body ONLY part numbers
BSP, aluminium SAE, aluminium SAE, steel
3/4” B19853
49.00 35.50 1” B19854 1” B23519 1” B23521
22.00 Ø24.00
75.50

50.00

25.00
2
38.00 A/F

57.25
13.00

HEX

76.20

8.70
45.50

2
THREAD
1
1-5/16"-12-UN

Ø28.50 1 65.10 5.50 22.50


44.50

CARTRIDGE ONLY COMPLETE VALVE 3/4” 1” PORTS


BASIC CODE: S902 (Normally Closed) BASIC CODE: S902 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium SAE, steel
49.00 35.50 3/4” B19853
Ø24.00 1” B19854 1” B23519 1” B23521
22.00
50.00
69.10

11
25.00

2
38.00 A/F
57.25
12.10

HEX
76.20

8.70
45.50

1-5/16"-12-UN
THREAD 2
1

65.10 5.50 22.50


Ø28.50 1
44.50
Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S901 N H 24 6W
Basic Code Port Sizes
S901 = (normally open) 6W = 3/4” BSP
S902 = (normally closed) 8W = 1” BSP 16T = 1” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw (S902 Only) H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-1276.B
S600 / S609 Directional Control Valve - 2-Way, 2-Position Poppet

100 litres/min (26 US GPM)  250 bar (3600 PSI)

S600 S609 FEATURES


NORMALLY OPEN NORMALLY CLOSED  High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
1
 Various coil terminals and voltages.

2  Coil interchangeability with all Series S2 valves.


 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

APPLICATION
To give on-off control of flows up to 100 litres/min (26
US GPM) and pressures up to 250 bar (3600 psi).
SPECIFICATIONS

Basic Model Code S600 (N.O.) S609 (N.C.)


2 2
COIL INFORMATION
Symbol
(See Page 11-1021)
1 1

Part Number: C13-*-*/14 Max. Working Pressure 250 bar (3600 psi)
Flow Rating 100 litres/min (26 US GPM)
Voltage available: 12, 24 VDC
110, 220 VAC* Nominal Flow 60 litres/min (16 US GPM)
(at Delta P = 5 bar (70 psi))
* AC coils must be used with a rectifying connector.
11 Internal Leakage
0.6 ml/min (10 dpm)
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU)
Recommended Filtration BS5540/4 18/13 (25 micron or better)
FLOW (US GPM) Compatible with most general
Fluid
0 5 10 15 20 25 purpose hydraulic fluids
40 580
Seal Material Standard nitrile with PTFE back up rings
Seal Kit Number SK390 (Nitrile) SK390V (Viton)
32 465
Mounting Position Unrestricted
PRESSURE (BAR)

PRESSURE (PSI)

24 350 Cartridge Weight 0.25 kg (0.55 lbs)


Coil Weight 0.2 kg (0.4 lbs)
16 230 Cavity Number A881 (See Section 17)
2-1
1-2
Torque into Cavity 60 Nm (44 lbs ft)
8 120
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy (up to 210 bar*)
0 20 40 60 80 100
FLOW (LITRES/MIN)

*For applications above 210 bar please consult our technical department or use the steel body option.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1311.A
48.00

CARTRIDGE ONLY 23.50 36.00


19.00 A/F
BASIC CODE: S600 (Normally Open)

NORMALLY CLOSED
S609 (Normally Closed)

NORMALLY OPEN
53.90

51.40

38.50
32.00 A/F

7.40
1"-14-UNS-2A
56.70

ø19.00 1

1/2” 3/4” PORTS COMPLETE VALVE 3/8” 1/2” 3/4” PORTS


COMPLETE VALVE
BASIC CODE: S600T (Normally Open)
BASIC CODE: S600 (Normally Open) S609T (Normally Closed)
S609 (Normally Closed)
Body ONLY part numbers Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, aluminium SAE, aluminium BSP, steel SAE, aluminium
1/2” B4851 1/2” B19403 3/8” C1084 3/8” B10784
3/4” B3954 3/4” B19404 1/2” C1044 1/2” C7140 1/2” C593
3/4” C1086 3/4” B10506 3/4” C4917 3/4” B10742

25.4
TORQUE
3.4Nm TORQUE
3.4Nm

2 HOLES
ø8.7 THRO'
12.7
13.00

35.0
35.00

2
71.4

2
50.80

11
89.00

92.0

1 1 1
1
2 HOLES
ø9.0 THRO'

19.00 10.00 19.00 31.8 6.3 38.1


50.80 38.10 50.8 50.8

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


S60* N H 24 4W T
Basic Code Body Type
S600 = (normally open) Omit = Standard
S609 = (normally closed) T = Through ported
Seals Port Sizes
N = Nitrile 3W = 3/8” BSP 6T = 3/8” SAE
V = Viton 4W = 1/2” BSP 8T = 1/2” SAE
6W = 3/4” BSP12T = 3/4” SAE
Manual Override (consult factory for
availability) Voltage
3 = Push (S600 Only) 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on
request
11-1312.B
7SP300 DIRECTIONAL CONTROL VALVE

2 WAY POPPET • 300 litres/min (80 US GPM) • 210 bar (3000 psi)

7SP300

PILOT SOLENOID CAVITY


OMITTED FOR CLARITY
NORMALLY NORMALLY
OPEN CLOSED

INLET 2

1 OUTLET

APPLICATION SPECIFICATIONS
To give on-off control of flows of 300 litres/min (80 US Figures based on: Oil Temp = 40°C Viscosity = 40 cSt
GPM) and pressures up to 210 bar (3000 psi) in any
hydraulic system. Can also be used as a high capacity,
Rated Flow 300 litres/min (80 US GPM)
fast acting, dump valve.

Working Pressure 210 bar (3000 psi)

OPERATION Working parts hardened and ground


Cartridge Material steel. External surfaces electroless
The normally open or normally closed pilot cartridge
nickel plated.
controls the vent flow through the main poppet. When
in the open mode, pilot flow passes through the orifice
Body Material Aluminium
in the poppet and the resultant pressure imbalance
causes the main section to open. As the movement of
11 the main poppet or spool is not limited by the solenoid
stroke, the valves have a flow capacity of 300 litres/min
Mounting Position Line mounted

(80 US GPM) with a low pressure drop. Weight (exc. coil) 1.90 kg (4.18 lbs)

Seal Kit Number SK433 (Nitrile) SK433V (Viton)


REVERSE PRESSURE
Recommended BS5540/4 Class 18/13
The valves are normally used for the bidirectional Filtration Level (25 micron nominal)
control of flow and the integral check valve ensures that
the main section will open and pass reverse flow Operating Temp -20°C to +90°C
regardless of the pilot mode. The normally closed
valve is typically used in line to an actuator to allow free Leakage 1 millilitre/min max (15 dpm)
flow in and control the flow out.
Nominal Viscosity 5 to 500 cSt
Range
FEATURES
Pilot Valve S203 / S204 (See page 11-141)
Through port line body construction for ready
installation into hydraulic lines. Fast resposne, high
flow capacity. Cartridge pilot section for easy
maintenance. A range of coils is available, see the
Ordering Code Example for voltage and termination
options.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1351.B
FLOW-US GPM
PRESSURE DROP 0 25 50 75
25

20 300

PRESSURE-BAR

PRESSURE-PSI
15

200

10

100
5

0
0 100 200 300
FLOW LITRES/MIN

COMPLETE VALVE 3/4” 1” PORTS


BASIC CODE: 7SP300
Sub-assembly part numbers
122.5
BSP, aluminium SAE, aluminium
NORMALLY OPEN
3/4” CXP3122-6W-S 101.6
1” CXP3122-8W-S 1” CXP3122-16T-S 119.0
NORMALLY CLOSED
17.5

22.0
9.5

43.0
71.0
2
95.0

76.5

1 SOLENOID CARTRIDGE
S201 / S202
(SEE PAGE 11-1111)
11
28.0
20.0
31.8
50.8
52.0
92.1
63.5

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

7SP300 1 6W H 24 S
Basic Code Seals
7SP300 = Complete valve S = Nitrile (For use with most
industrial hydraulic oils)
Solenoid Configuration SV = Viton (For high temperature
1 = Normally open and most special fluid
2 = Normally closed applications)
Port Sizes - Bodied Valves Only
6W = 3/4” BSP Coil Voltage
8W = 1” BSP 16T = 1” SAE 12 = 12VDC
24 = 24VDC
Coil Termination 110 = 110VAC 50 Hz
H = ISO4400 (plug included) 220 = 220VAC 50 Hz
F = Flying Leads DC only Other voltages available
DM = Deutsch Moulded on request
Other terminations available on request We reserve the right to change specifications without notice

11-1352.B
SX203 / SX204 Directional Control Valve - 2-Way, 2-Position
Poppet
20 litres/min (5 US GPM)  350 bar (5000 PSI)

SX203 SX204 COIL INFORMATION


NORMALLY OPEN NORMALLY CLOSED (See Page 11-1021)
(as shown)
Part Number: C13-*-*/22

Voltage available: 12, 24 VDC


110, 220 VAC*
1
* AC coils must be used with a rectifying connector.
2
FEATURES
APPLICATION  High flow capacity with reduced space requirements.
 No dynamic seals.
To give on-off control of flows of 20 litres/min (5 US  Standard valve bodies and common cavities.
GPM) and pressures up to 350 bar (5000 psi). Typical  One-piece encapsulated coil with minimal amperage
usage includes the control of actuators in a hydraulic draw.
system.  Oil immersed armature solenoid.
 Various coil terminals and voltages.
OPERATION  Coil interchangeability with all Series S2 valves.
Normally Open  Manual override, seal variations and other options
De-energised; 2 to 1 – full flow, pressure difference available.
through the pilot orifice holds the main poppet open. 1  Sealed coil arrangement to protect stem from corrosion.
to 2 – restricted flow, main poppet pressure biased
onto its seat, pilot orifice open. SPECIFICATIONS
Energised; 2 to 1 - No flow, pilot orifice closed, main
poppet pressure biased onto its seat. 1 to 2 – full flow
when solenoid force overcome. Basic Model Code SX203 (N.O.) SX204 (N.C.)
2 2

Normally Closed Basic Model Code


De-energised; 2 to 1 – no flow, pilot orifice closed,
1 1
main poppet pressure biased onto its seat. 1 to 2 – full
flow when spring force overcome. Max. Working Pressure SX203: 280bar (4000psi)
Energised; 2 to 1- full flow, pressure difference through SX204: 350bar (5000psi)
the pilot orifice holds the main poppet open. 1 to 2 –
11 restricted flow, main poppet pressure biased onto its
seat, pilot orifice open.
Cartridge Material Working parts hardened and
ground steel

Standard aluminium (up to 210 bar*)


Body Material
PRESSURE DROP v’s FLOW Add suffix ‘377’ for steel option
Viscosity = 32 cSt (150 SSU) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
Mounting Position Unrestricted
18 260
SX203 (280 bar) 15 210 Cavity Number A879 (See Section 17)
(Normally Open)
PRESSURE (BAR)

PRESSURE (PSI)

12 175
1-2 Energised
Torque Cartridge into
9 130
30 Nm (22 lbs ft)
Cavity
6 90

2-1 De-energised
3 45
Weight (exc. coil) 0.08 kg (0.18lbs)
0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)
FLOW (US GPM)
Seal Kit Number SK1043 (Nitrile) SK1043V (Viton)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
15 210 Recommended BS5540/4 (25 micron nominal)
SX204 (350 bar) 12 175
Filtration Level Class 18/13
(Normally Closed)
PRESSURE (BAR)

PRESSURE (PSI)

9 130 Operating Temp -20 C to +90 C


1-2 De-energised
6 90
2-1 Energised Leakage 0.6 millilitres/min (10 dpm) closed)
3 45

0 0
Nominal Viscosity 5 to 500 cSt
0 5 10 15 20 25 30 35 40 Range
FLOW (LITRES/MIN)

*For applications above 210 bar please consult our technical department or use the steel body option.
Integrated Hydraulics Ltd Integrated Hydraulics Inc
Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1431.A
CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS
BASIC CODE: SX203 (Normally Open) 280 bar BASIC CODE: SX203 (Normally Open) 280 bar
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843

48.00 50.00
23.50 36.00
59.00

38.50

2 HOLES
ø6.8 THRO'
24.00 A/F

12.80
8.25

50.80
27.30

3/4"-16-UNF-2A
2 1

22.00
ø12.60 1

6.00
15.90
16.00
6.00 31.80
19.00

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: SX204 (Normally Closed) 350 bar BASIC CODE: SX204 (Normally Closed) 350 bar
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
50.00
48.00

23.50 36.00
55.50

38.50

2
2 HOLES
ø6.8 THRO'
11
12.80

24.00 A/F
50.80
9.55
27.30

3/4"-16-UNF-2A 1
22.00

1
6.00

ø12.60 15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

SX*** N H 24 3W
Basic Code Port Sizes
SX203 = (normally open) 280 bar 2W = 1/4” BSP
SX204 = (normally closed) 350 bar 3W = 3/8” BSP 6T = 3/8” SAE
Voltage
Seals 12 = 12 VDC 110 = 110 VAC
N = Nitrile 24 = 24 VDC 220 = 220 VAC
V = Viton
Coil Termination
Manual Override (consult factory for availability) H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-1432.C
S205 / S206 Directional Control Valve - 2-Way, 2-Position Poppet

1 litre/min (0.25 US GPM)  210 bar (3000 PSI)

S205 S206 FEATURES


NORMALLY OPEN NORMALLY CLOSED
 Pilot flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
1  Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
2
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

APPLICATION
To give on-off control of flows up to 1 litre/min (0.25 US
GPM) and pressures up to 210 bar (3000 psi). Typical
usage includes the control of the pilot or vent flow of SPECIFICATIONS
another valve, for example a ventable relief valve. (See
Section 2). S205 (N.O.) S206 (N.C.)
Basic Model Code
2 2

COIL INFORMATION Symbol


1 1
(See Page 11-1021)
Max. Working Pressure 210 bar (3000 psi)
Part Number: C13-*-*/14
Flow Rating 1 litre/min (0.25 US GPM)
Voltage available: 12, 24 VDC Nominal Flow 1 litre/min (0.25 US GPM)
110, 220 VAC* (at Delta P = 5 bar (70 psi))

11 * AC coils must be used with a rectifying connector. Internal Leakage 0.3 ml/min (5 dpm) when closed
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)
FLOW-US GPM
Fluid Compatible with most general
0 0.1 0.2 0.3 0.4 purpose hydraulic fluids
16 240
Seal Material Standard nitrile with PTFE back up rings
14
Seal Kit Number SK1043 (Nitrile) SK1043V (Viton)
12 160
Mounting Position Unrestricted
10 Cartridge Weight 0.1 kg (0.2 lbs)
PRESSURE-BAR

PRESSURE-PSI

8 120 Coil Weight 0.2 kg (0.4 lbs)


Cavity Number A879 (See Section 17)
6
Torque into Cavity 22 Nm (15 lbs ft)
4 60
Electrical Data See coil data sheet
2
Line Body Material Aluminium Alloy
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
FLOW LITRES/MIN

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1611.A
CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS
BASIC CODE: S205 (Normally Open) BASIC CODE: S205 (Normally Open)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
50.00
48.00
23.50 36.00
59.00

38.50

2 HOLES
ø6.8 THRO'

24.00 A/F

12.80
2

50.80
9.55
27.30

3/4"-16-UNF-2A
2 1

22.00
1
ø12.60

6.00
15.90
16.00
6.00 31.80
19.00

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S206 (Normally Closed) BASIC CODE: S206 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
48.00 50.00
23.50 36.00
55.50

38.50

24.00 A/F 2
2 HOLES
ø6.8 THRO'
11
9.55

12.80

50.80
27.30

3/4"-16-UNF-2A
2
1
22.00

1
ø12.60
6.00

15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S205 N H 24 3W
Basic Code Port Sizes
S205 = (normally open) 2W = 1/4” BSP
S206 = (normally closed) 3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


1 = Push and twist (S206 Only) H = DIN43650
2 = Screw (S205 & S206) F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-1612.B
S207 Directional Control Valve - 2-Way, 2-Position Poppet

1 litre/min (0.25 US GPM)  350 bar (5000 PSI)

S207 FEATURES
NORMALLY OPEN  Pilot flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2  Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
APPLICATION
To give on-off control of flows up to1 litre/min (0.25 US
GPM) and pressures up to 350 bar (5000 psi). Typical
usage includes the control of the pilot or vent flow of
another valve, for example a ventable relief valve.
(See Section 2). SPECIFICATIONS
NOTE: This valve can be used to vent systems at
pressures up to 350 bar (5000 psi) on the Basic Model Code S207
inlet port but pressure on the outlet port 1
should be limited to 210 bar (3000 psi).
Symbol
2
COIL INFORMATION
210 bar (3000 psi) - Port 2
(See Page 11-1021) Max. Working Pressure
350 bar (5000 psi) - Port 1

Part Number: C13-*-*/22 Flow Rating 1 litre/min (0.25 US GPM)

Nominal Flow
Voltage available: 12, 24 VDC 1 litre/min (0.25 US GPM)

11 110, 220 VAC*


(at Delta P = 5 bar (70 psi))

Internal Leakage 0.3 ml/min (5 dpm) when energised


* AC coils must be used with a rectifying connector. 210 bar differential at 32 centistokes
PRESSURE DROP v’s FLOW Temperature Range -20 to +120°C (-4 to +248°F)
Viscosity = 32 cSt (150 SSU) Nominal Viscosity Range 15 to 250 centistokes
FLOW-US GPM
Recommended Filtration BS5540/4 18/13 (25 micron or better)
0 0.1 0.2 0.3 0.4
16 240
Fluid Compatible with most general
purpose hydraulic fluids
14
Seal Material Standard nitrile with PTFE back up rings
12 160
Seal Kit Number SK1043V (Viton)
10
Mounting Position Unrestricted
PRESSURE-BAR

PRESSURE-PSI

8 120 Cartridge Weight 0.1 kg (0.2 lbs)


6 Coil Weight 0.2 kg (0.4 lbs)

60
Cavity Number A879 (See page 11-441)
4
Torque into Cavity 20 Nm (15 lbs ft)
2
Electrical Data See coil data sheet
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Line Body Material Aluminium Alloy (up to 210 bar*)
FLOW LITRES/MIN
*For applications above 210 bar please consult our technical department or use the steel body option.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1711.A
CARTRIDGE ONLY
BASIC CODE: S207 48.00

23.50 36.00
59.00

38.50
24.00 A/F

8.25
27.30

3/4"-16-UNF-2A
2

1
ø12.60

COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S207
Body ONLY part numbers
BSP, aluminium SAE, aluminium 50.00
1/4” A1485
3/8” A1043 3/8” A15676

BSP, steel SAE, steel


3/8” A14175 3/8” A14843

2 HOLES
ø6.8 THRO'
12.80

2
50.80

1 11
22.00
6.00

15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S207 V H 24 3W
Basic Code Port Sizes
S207 = (normally open) 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
V = Viton Voltage
12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC

Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-1712.C
S607 / S608 & S612 / S613 Directional Control Valve
2-Way, 2-Position Poppet/Spool
100 litres/min (26 US GPM)  250 bar (3600 PSI)

S607 S608 FEATURES


POPPET TYPE POPPET TYPE  High flow capacity with reduced space requirements.
NORMALLY OPEN NORMALLY CLOSED
(as shown)  No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2  Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
S612 S613
 Sealed coil arrangement to protect stem from corrosion.
SPOOL TYPE SPOOL TYPE
NORMALLY OPEN NORMALLY CLOSED SPECIFICATIONS
(as shown)
S607 Poppet Type (N.O.)
S608 Poppet Type (N.C.)
Basic Model Code S612 Spool Type (N.O.)
S613 Spool Type (N.C.)
1
S607 S608
2 2 2

1 1
Symbol
APPLICATION S612 S613
2 2
To give on-off control of flows up to 100 litres/min (26
US GPM) and pressures up to 250 bar (3600 psi). 1 1

Max. Working Pressure 250 bar (3600 psi)


COIL INFORMATION Flow Rating 100 litres/min (26 US GPM)
(See Page 11-1021) Nominal Flow
90 litres/min (23 US GPM)
(at Delta P = 5 bar (70 psi))

11 Part Number:

Voltage available: 12, 24 VDC


C13-*-*/14

Internal Leakage
S607/S608: 0.6 ml/min (10 dpm)
S612/S613: Less than 60 ml/min
110, 220 VAC* 210 bar differential at 32 centistokes

* AC coils must be used with a rectifying connector. Temperature Range -20 to +120°C (-4 to +248°F)
Nominal Viscosity Range 15 to 250 centistokes
PRESSURE DROP v’s FLOW
Recommended Filtration BS5540/4 18/13 (25 micron or better)
Viscosity = 32 cSt (150 SSU)
Fluid Compatible with most general
FLOW-US GPM
0 8 16 24 32 40
purpose hydraulic fluids
24 350
Seal Material Standard nitrile with PTFE back up rings
20 290 Seal Kit Number SK390 (Nitrile) SK390V (Viton)
PRESSURE-BAR

PRESSURE-PSI

16 230 Mounting Position Unrestricted

12 175
Cartridge Weight 0.25 kg (0.55 lbs)
S607 & S608
Coil Weight 0.2 kg (0.4 lbs)
8 120
Cavity Number A881 (See Section 17)
4 60
S612 & S613 Torque into Cavity 60 Nm (44 lbs ft)

0 30 60 90 120 150
Electrical Data See coil data sheet
FLOW LITRES/MIN Line Body Material Aluminium Alloy (up to 210 bar*)

*For applications above 210 bar please consult our technical department or use the steel body option.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1811.B
CARTRIDGE ONLY
BASIC CODE: S607 Poppet Type (N.O.) S612 Spool Type (N.O.)
S608 Poppet Type (N.C.) S613 Spool Type (N.C.)
48.00

23.50 36.00
19.00 A/F
NORMALLY CLOSED
NORMALLY OPEN
53.90

51.40

38.50
32.00 A/F

7.40
1"-14-UNS-2A
56.70

ø19.00 1

COMPLETE VALVE 1/2” 3/4” PORTS


BASIC CODE: S607 Poppet Type (N.O.) S612 Spool Type (N.O.)
S608 Poppet Type (N.C.) S613 Spool Type (N.C.)
Body ONLY part numbers Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, aluminium SAE, aluminium BSP, steel SAE, aluminium
1/2” B4851 1/2” B19403 3/8” C1084 3/8” B10784
3/4” B3954 3/4” B19404 1/2” C1044 1/2” C7140 1/2” C593
3/4” C1086 3/4” B10506 3/4” C4917 3/4” B10742
25.4
TORQUE
3.4Nm TORQUE
3.4Nm

2 HOLES ø8.7
THRO'
13.00

12.7
35.0
35.00

2
50.80

2 2
71.4
92.0
89.00

1 1 1 1
11
2 HOLES
ø9.0 THRO'

19.00 10.00 19.00 31.8 6.3 38.1


50.80 38.10 50.8
50.8
Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S6** N H 24 4W T
Body Type
Basic Code Omit = Standard
S607 = Poppet Type (normally open) T = Through ported
S608 = Poppet Type (normally closed) Port Sizes
S612 = Spool Type (normally open) 3W = 3/8” BSP 6T = 3/8” SAE
S613 = Spool Type (normally closed) 4W = 1/2” BSP 8T = 1/2” SAE
6W = 3/4” BSP 12T = 3/4” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for Coil Termination
availability) H = DIN43650
3 = Push (S607 & 612) F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request

We reserve the right to change specifications without notice

11-1812.B
S210 / S211 Directional Control Valve - 2-Way, 2-Position Spool

Up to 20 litres/min (5 US GPM)  210 bar (3000 PSI)

S210 S211 FEATURES


NORMALLY OPEN NORMALLY CLOSED  High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
1
 Various coil terminals and voltages.
2  Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/14

Voltage available: 12, 24 VDC SPECIFICATIONS


110, 220 VAC*
Basic Model Code S210 (N.O.) S211 (N.C.)
* AC coils must be used with a rectifying connector.
2 2
Symbol
PRESSURE DROP v’s FLOW 1 1

Max. Working Pressure 210 bar (3000 psi)


Viscosity = 32 cSt (150 SSU)
Flow Rating See performance graphs
S210 (Normally Open)
Nominal Flow 15 litres/min (4 US GPM)
FLOW (US GPM) (at Delta P = 5 bar (70 psi))
1 2 3 4 5 6

11 15

12
210

175
Internal Leakage Less than 60 ml/min
210 bar differential at 32 centistokes
PRESSURE (BAR)

PRESSURE (PSI)

Temperature Range -20 to +120°C (-4 to +248°F)


9 130
Nominal Viscosity Range 15 to 250 centistokes
6 90
Recommended Filtration BS5540/4 18/13 (25 micron or better)
3 45
Fluid Compatible with most general
0
purpose hydraulic fluids
0
0 4 8 12 16 20 24
FLOW (LITRES/MIN) Seal Material Standard nitrile with PTFE back up rings
Seal Kit Number SK972 (Nitrile) SK972V (Viton)
S211 (Normally Closed)
FLOW (US GPM) Mounting Position Unrestricted
1 2 3 4 5 6
15
Cartridge Weight 0.125 kg (0.3 lbs)
210
Coil Weight 0.2 kg (0.4 lbs)
12 175
PRESSURE (BAR)

PRESSURE (PSI)

Cavity Number A6701 (See Section 17)


9 130
Torque into Cavity 20 Nm (15 lbs ft)
6 90 Electrical Data See coil data sheet

3 45 Line Body Material Aluminium Alloy

0 0
0 4 8 12 16 20 24
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-1911.A
PERFORMANCE PERFORMANCE
S210 (Normally open) S211 (Normally closed)
FLOW (US GPM) FLOW (US GPM)
1.25 2.5 3.75 5 6.5 1.3 2.6 3.9 5.2 6.5 7.8 9.1
250 3625 250 3625
2-1

WORKING PRESSURE (PSI)


WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900 200 2900
1-2
150 2175 2175
150

2-1
100 1450 100 1450

1-2
50 725 725
50

0 0 0 0
0 5 10 15 20 25 0 5 10 15 20 25 30 35
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S210 (Normally Open) BASIC CODE: S210 (Normally Open)
S211 (Normally Closed) S211 (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” A12592
3/8” A7450 3/8” A19355

50.00

48.00

23.50 36.00
38.50
55.50

2 HOLES

24.00 A/F
2
ø6.8 THRO'
11
12.80

50.80
9.55
25.15

3/4"-16-UNF-2A
2 1
22.00

1
ø15.80
6.00

15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S21* N H 24 3W
Basic Code Port Sizes
S210 = (normally open) 2W = 1/4” BSP
S211 = (normally closed) 3W = 3/8” BSP 6T = 3/8” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability) Coil Termination
1 = Push and twist (S210 & S211) H = DIN43650
2 = Screw (S210 & S211) F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-1912.B
S510(H) / S511(H) Directional Control Valve
2-Way, 2-Position Spool
Up to 25 litres/min (6.5 US GPM)  Up to 210 bar (3000 PSI)

S510(H) S511(H) FEATURES


NORMALLY OPEN NORMALLY CLOSED  High flow capacity with reduced space requirements.
(as shown)
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
1
 Coil interchangeability with all Series S5 valves.
2  Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION SPECIFICATIONS


(See Page 11-1021)
Basic Model Code S510(H) (N.O.) S511(H) (N.C.)
Part Number: C16-*-*/19 (S510 / S511) 2 2
C16-*-*/29 (S510H / S511H) Symbol
1 1
Voltage available: 12, 24 VDC
110, 220 VAC* Max. Working Pressure 210 bar (3000 psi)
Flow Rating See performance graphs
* AC coils must be used with a rectifying connector.
Nominal flow
22 litres/min (6 US GPM)
(at Delta P = 5 bar (70 psi))

11 Internal Leakage
Less than 120 ml/min
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)

FLOW (US GPM) Compatible with most general


Fluid
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 purpose hydraulic fluids
15 210
Seal Material Standard nitrile with PTFE back up rings
12 175 Seal Kit Number SK1028 (Nitrile) SK1028V (Viton)
PRESSURE (BAR)

PRESSURE (PSI)

Mounting Position Unrestricted


9 130
Cartridge Weight 0.2 kg (0.4 lbs)
6 90
Coil Weight 0.3 kg (0.6 lbs)

45
Cavity Number A12370 (See Section 17)
3
Torque into Cavity 30 Nm (22 lbs ft)
0 0
0 10 15 20 25 30 35 40
Electrical Data See coil data sheet
5
FLOW (LITRES/MIN) Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2011.A
PERFORMANCE PERFORMANCE
S510 / S511 (Standard valve) S510H / S511H (Heavy duty valve)
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 1.3 2.6 3.9 5.2 6.5 7.8 9.1
250 3625 250 3625

WORKING PRESSURE (PSI)


S510H
WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)


WORKING PRESSURE (PSI)
200 2900 200 2900
S511H
150 2175 150 2175

S510
100 1450 100 1450

S511
50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35

FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S510(H) (Normally Open) BASIC CODE: S510(H) (Normally Open)
S511(H) (Normally Closed) S511(H) (Normally Closed)
Body ONLY part numbers
BSP, aluminium SAE, aluminium SAE, steel
3/8” B19053
1/2” B19356 1/2” B19402 1/2” B20601

49.00 50.80
35.50
21.00
50.00
66.00

11
18.50
38.10

25.40 A/F 2
8.30

50.80
32.40

7/8"-14-UNF-2A 1
2
7.10

1 19.10 16.00
ø15.80
3.15 41.30 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S51** N H 24 3W
Basic Code Port Sizes
S510 = (normally open - standard valve) 3W = 3/8” BSP
S510H = (normally open - heavy duty valve) 4W = 1/2” BSP 8T = 1/2” SAE
S511 = (normally closed - standard valve)
S511H = (normally closed - heavy duty valve) Voltage
12 = 12 VDC 110 = 110 VAC
Seals 24 = 24 VDC 220 = 220 VAC
N = Nitrile
V = Viton Coil Termination
H = DIN43650
Manual Override (consult factory for availability) F = Flying Leads
2 = Screw (S510(H) & S511(H)) DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2012.B
S215 Directional Control Valve
2-Way, 2-Position Bi-Directional Poppet
Up to 1 litre/min (0.26 US GPM)  Up to 210 bar (3000 PSI)

S215 FEATURES
NORMALLY CLOSED  Very low leakage poppet design.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
2
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
1
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS
COIL INFORMATION
(See Page 11-1021)
Basic Model Code S215
Part Number: C13-*-*/14 2

Symbol
Voltage available: 12, 24 VDC 1
110, 220 VAC*
Max. Working Pressure 210 bar (3000 psi)
* AC coils must be used with a rectifying connector. Flow Rating See performance graphs

Nominal flow
1 litres/min (0.26 US GPM)
(at Delta P = 5 bar (70 psi))

11 Internal Leakage
Less than 0.3 ml/min (5 dpm)
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)

Compatible with most general


Fluid
purpose hydraulic fluids

FLOW US (GPM)
Seal Material Standard nitrile with PTFE back up rings
0 0.1 0.25 0.4 0.55 Seal Kit Number SK1043 (Nitrile) SK1043V (Viton)
25 Mounting Position Unrestricted
20 300 Cartridge Weight 0.15 kg (0.3 lbs)
PRESSURE-BAR

PRESSURE-PSI

15 Coil Weight 0.2 kg (0.4 lbs)


200
Cavity Number A879 (See Section 17)
10
100 Torque into Cavity 20 Nm (15 lbs ft)
5
Electrical Data See coil data sheet

0 0.5 1.0 1.5 2


Line Body Material Aluminium Alloy
FLOW LITRES/MIN

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2051.A
PERFORMANCE

FLOW (US GPM)


0.125 0.25
250

WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 3000

150
2000

100
1000
50

0 0
0 0.25 0.5 0.75 1.0 1.25

FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S215 BASIC CODE: S215
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843

50.00

48.00
23.50 36.00
55.50

38.50

2 HOLES
ø6.8 THRO'
2

11
12.80

50.80

24.00 A/F
9.55

1
27.30

3/4"-16-UNF-2A
22.00

1
6.00

ø12.60 15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S215 N H 24 3W
Basic Code Port Sizes
S215 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
1 = Push and Twist Coil Termination
2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2052.B
S217(H) Directional Control Valve
2-Way, 2-Position Bi-Directional Poppet
Up to 20 litres/min (5 US GPM)  Up to 210 bar (3000 PSI)

S217(H) FEATURES
NORMALLY CLOSED  Very low leakage poppet design.
 Standard valve bodies and common cavities.

2  One-piece encapsulated coil with minimal amperage draw.


 Oil immersed armature solenoid.
1  Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS
COIL INFORMATION
(See Page 11-1021)
Basic Model Code S217(H)
Part Number: C16-*-*/19 (S217) 2
C16-*-*/29 (S217H) Symbol
1
Voltage available: 12, 24 VDC
110, 220 VAC* Max. Working Pressure 210 bar (3000 psi)
Flow Rating See performance graphs
* AC coils must be used with a rectifying connector.
Nominal flow
20 litres/min (5 US GPM)
(at Delta P = 5 bar (70 psi))

11 Internal Leakage
Less than 0.6 ml/min (10 dpm)
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)

Compatible with most general


Fluid
FLOW (US GPM)
purpose hydraulic fluids
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
40 580 Seal Material Standard nitrile with PTFE back up rings
Seal Kit Number SK1157 (Nitrile) SK1157V (Viton)
PRESSURE (BAR)

PRESSURE (PSI)

30 435
Mounting Position Unrestricted
20 290 Cartridge Weight 0.17 kg (0.37 lbs)
2-1 1-2 Coil Weight 0.3 kg (0.6 lbs)
10 145
Cavity Number A879 (See Section 17)
0 0 Torque into Cavity 20 Nm (15 lbs ft)
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2071.A
PERFORMANCE PERFORMANCE
S217 (standard valve) S217H (Heavy duty valve)
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625

WORKING PRESSURE (BAR)


WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


WORKING PRESSURE (PSI)
200 2900 200 2900
1-2 1-2

150 2175 150 2175


2-1 2-1

100 1450 100 1450

50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S217(H) BASIC CODE: S217(H)
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843

50.00

49.00
35.50
21.00
50.00
72.00

2 HOLES
ø6.8 THRO'

11
12.80

2
50.80

24.00 A/F 1
22.00
9.25
27.40

3/4"-16-UNF-2A
2
6.00

15.90
16.00
ø12.60 1
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S217* N H 24 3W
Basic Code Port Sizes
S217 = (standard valve) 2W = 1/4” BSP
S217H = (heavy duty valve) 3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw H = DIN43650
3 = Push F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2072.B
S217A Directional Control Valve
2-Way, 2-Position Bi-Directional Poppet
Up to 10 litres/min (2.6 US GPM)  Up to 210 bar (3000 PSI)

S217A FEATURES
NORMALLY CLOSED  Very low leakage poppet design.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
2
 Various coil terminals and voltages.
1  Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS
COIL INFORMATION
(See Page 11-1021)
Basic Model Code S217A
Part Number: C13-*-*/27 2

Symbol
Voltage available: 12, 24 VDC 1
110, 220 VAC*
Max. Working Pressure 210 bar (3000 psi)
* AC coils must be used with a rectifying connector. Flow Rating See performance graphs

Nominal flow
10 litres/min (2.6 US GPM)
(at Delta P = 5 bar (70 psi))

11 Internal Leakage
Less than 0.6 ml/min (10 dpm)
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)

Compatible with most general


Fluid
purpose hydraulic fluids
FLOW (US GPM) Seal Material Standard nitrile with PTFE back up rings
1.3 2.6 3.9 5.2 6.5 7.8
40 580 Seal Kit Number SK1043 (Nitrile) SK1043V (Viton)
Mounting Position Unrestricted
435
PRESSURE (BAR)

PRESSURE (PSI)

30
Cartridge Weight 0.2 kg (0.4 lbs)
2-1
20 290 Coil Weight 0.2 kg (0.4 lbs)
1-2 Cavity Number A879 (See Section 17)
10 145
Torque into Cavity 20 Nm (15 lbs ft)
0 0
0 5 10 15 20 25 30
Electrical Data See coil data sheet
FLOW (LITRES/MIN) Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2073.A
PERFORMANCE
FLOW (US GPM)
1 2 3 4 5
WORKING PRESSURE (BAR) 250

WORKING PRESSURE (PSI)


3000
200
1-2
150
2000
2-1

100
1000

50

0 0
0 5 10 15 20
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S217A BASIC CODE: S217A
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485
3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843

50.00
48.00

23.50 36.00
59.00

38.50

2 HOLES
ø6.8 THRO'

24.00 A/F
11
12.80

2
50.80
8.25
27.30

3/4"-16-UNF-2A 1
22.00

ø12.60 1
6.00

15.90
16.00
6.00 31.80
19.00

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S217A N H 24 3W
Basic Code Port Sizes
S217A 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
2 = Screw Coil Termination
3 = Push H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2074.B
S716 / S717 Directional Control Valve
2-Way, 2-Position Bi-Directional Poppet
Up to 90 litres/min (24 US GPM)  Up to 350 bar (5000 PSI)

S716 S717 FEATURES


NORMALLY OPEN NORMALLY CLOSED  Very low leakage poppet design.
(as shown)
 Standard valve bodies and common cavities.
2  One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
1
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION SPECIFICATIONS


(See Page 11-1021) Basic Model Code S716 (N.O.) S717 (N.C.)
Part Number: C13-*-*/22
2 2

Voltage available: 12, 24 VDC Symbol


110, 220 VAC* 1 1

* AC coils must be used with a rectifying connector. S716: 280 bar (4060 psi)
Max. Working Pressure
S717: 350 bar (5000 psi)

Flow Rating See performance graphs


Nominal flow 90 litres/min (24 US GPM)
PRESSURE DROP v’s FLOW
Less than 2.7 ml/min (40 dpm)
Viscosity = 32 cSt (150 SSU) Internal Leakage
350 bar differential at 32 centistokes
S716 (Normally Open) Temperature Range -20 to +120°C (-4 to +248°F)

FLOW-US GPM Nominal Viscosity Range 15 to 250 centistokes


0 5 10 15 20 25 Recommended Filtration BS5540/4 18/13 (25 micron or better)

11
25
350
Compatible with most general
20 300 Fluid
PRESSURE-BAR

purpose hydraulic fluids


PRESSURE-PSI

250
15
2-1 200 Seal Material Standard nitrile with PTFE back up rings
10 150
1-2 Seal Kit Number SK1225 (Nitrile) SK1225V (Viton)
100
5
50 Mounting Position Unrestricted

0 20 40 60 80 100 Cartridge Weight 0.17 kg (0.37 lbs)


FLOW LITRES/MIN
Coil Weight 0.2 kg (0.4 lbs)
Cavity Number A21473 (See Section 17)
S717 (Normally Closed)
Torque into Cavity 110 Nm (81 ft)
FLOW-US GPM
0 5 10 15 20 25
Electrical Data See coil data sheet
25
350
Aluminium Alloy / Steel for pressures
Line Body Material
20 300
above 210 bar.
PRESSURE-BAR

PRESSURE-PSI

250
15
1-2 200
10 150 *For applications above 210 bar please consult our
2-1
100
technical department or use the steel body option.
5
50

0 20 40 60 80 100
FLOW LITRES/MIN

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11.2091.C
CARTRIDGE ONLY COMPLETE VALVE 3/4” PORTS
BASIC CODE: S716 (Normally Open) BASIC CODE: S716
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
3/4” B22258 3/4” B22260 3/4” B22262 3/4” B22264
88.90
36.00
38.50
70.40

31.75 A/F CT1

28.50
21.00

88.90
76.20
63.50
2
51.00

1-1/16"-12-UN-2A
2
1

44.45 2 HOLES
Ø10.5 THRO 25.40
Ø 23.75 1 63.50 12.70 50.80

CARTRIDGE ONLY COMPLETE VALVE 3/4” PORTS


BASIC CODE: S717 (Normally Closed) BASIC CODE: S717
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
3/4” B22258 3/4” B22260 3/4” B22262 3/4” B22264

36.00 88.90
38.50
67.00

31.75 A/F

11
21.00

CT1
28.50
76.20
63.50

88.90

2
1-1/16"-12-UN-2A
51.00

2
1
2 HOLES
Ø10.50 THRO'
1 44.50 25.40
Ø 23.75
63.50 12.70 50.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


S717 N H 24 6W
Basic Code Port Sizes
S716 = (Normally open) 6W = 3/4” BSP 12T = 3/4” SAE
S717 = (Normally closed)
Voltage
Seals 12 = 12 VDC 110 = 110 VAC
N = Nitrile 24 = 24 VDC 220 = 220 VAC
V = Viton
Coil Termination
Manual Override (consult factory for availability) H = DIN43650
2 = Screw (S717 only) F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11.2092.B
S220(H) Directional Control Valve - 3-Way, 2-Position Spool

Up to 14 litres/min (3.7 US GPM)  Up to 210 bar (3000 PSI)

S220(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.

1
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
2 3
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.

APPLICATION  Sealed coil arrangement to protect stem from corrosion.

NORMALLY NORMALLY
CLOSED OPEN SELECTOR
(Pressure at Port 3) (Pressure at Port 2) (Pressure at Port 1) SPECIFICATIONS
ACTUATOR ACTUATOR
(1) (1) P (1)
Basic Model Code S220 (std) / S220H (heavy duty)
1
Symbol
T P P T ACT.1 ACT.2
(2) (3) (2) (3) (2) (3) 2 3

Actuator Port Location Port 1


Max. Working Pressure 210 bar (3000 psi)

COIL INFORMATION Flow Rating See performance graphs


Nominal flow
(See Page 11-1021) 11 litres/min (3 US GPM)
(at Delta P = 5 bar (70 psi))

Part Number: C13-*-*/14 (S220) Less than 60 ml/min past each land
C13-*-*/27 (S220H) Internal Leakage
210 bar differential at 32 centistokes
11 Voltage available: 12, 24 VDC Temperature Range -20 to +120°C (-4 to +248°F)
110, 220 VAC* Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)
* AC coils must be used with a rectifying connector.
Compatible with most general
Fluid
purpose hydraulic fluids
PRESSURE DROP v’s FLOW Seal Material Standard nitrile with PTFE back up rings
Viscosity = 32 cSt (150 SSU) Seal Kit Number SK973 (Nitrile) SK973V (Viton)
FLOW (US GPM) Mounting Position Unrestricted
0.5 1 1.5 2 2.5 3 3.5 Cartridge Weight 0.13 kg (0.3 lbs)
12.5 181
Coil Weight 0.2 kg (0.4 lbs)
10.0 145
Cavity Number A3531 (See Section 17)
PRESSURE (BAR)

PRESSURE (PSI)

7.5 109 Torque into Cavity 20 Nm (15 lbs ft)


Electrical Data See coil data sheet
5.0 72
Line Body Material Aluminium Alloy
2.5 36

0 0
0 2 4 6 8 10 12 14
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2111.A
PERFORMANCE PERFORMANCE
S220 (Standard valve) S220H (Heavy duty valve)
FLOW (US GPM) FLOW (US GPM)
0 0.2 0.5 0.7 1.0 1.2 1.5 1.7 2.0 2.2 2.5 0 0.2 0.5 0.7 1.0 1.2 1.5 1.7 2.0 2.2 2.5
250 250
3750 3750
NORMALLY CLOSED SELECTOR
WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)


WORKING PRESSURE (PSI)
3000

WORKING PRESSURE (PSI)


200 200 3000

NORMALLY
150 2250 150 2250
CLOSED
NORMALLY SELECTOR
OPEN NORMALLY OPEN
100 1500 100 1500

50 750 50 750

0 0
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S220 / S220H BASIC CODE: S220 / S220H
Body ONLY part numbers
48.00 BSP, aluminium SAE, aluminium
1/4” B7724
23.50 36.00 3/8” B6684 3/8” B6516
57.20
38.50
55.50

11.10

14.70

24.00 A/F
28.30
9.55

3/4"-16-UNF-2A

11
3
3 2
44.00

38.10

63.50

2
1

2 HOLES
1 ø7.1 THRO'
ø14.20
28.60 12.70
ø15.80
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S220* N H 24 3W
Basic Code Port Sizes
S220 = (standard valve) 2W = 1/4” BSP
S220H = (heavy duty valve) 3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


1 = Push and twist H = DIN43650
2 = Screw F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2112.B
S520(H) Directional Control Valve - 3-Way, 2-Position Spool

Up to 40 litres/min (10 US GPM)  Up to 210 bar (3000 PSI)

S520(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
APPLICATION  Sealed coil arrangement to protect stem from corrosion.

NORMALLY NORMALLY
CLOSED OPEN SELECTOR
(Pressure at Port 3) (Pressure at Port 2) (Pressure at Port 1) SPECIFICATIONS
ACTUATOR ACTUATOR
(1) (1) P (1)
Basic Model Code S520 (std) / S520H (heavy duty)

1
T P P T ACT.1 ACT.2
(2) (3) (2) (3) (2) (3) Symbol
2 3

Actuator Port Location Port 1


COIL INFORMATION
Max. Working Pressure 210 bar (3000 psi)
(See Page 11-1021) Flow Rating See performance graphs

Part Number: C16-*-*/19 (S520) Nominal flow


22 litres/min (6 US GPM)
C16-*-*/29 (S520H) (at Delta P = 5 bar (70 psi))

11 Voltage available: 12, 24 VDC


110, 220 VAC*
Internal Leakage
Less than 120 ml/min past each land
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


* AC coils must be used with a rectifying connector. Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)
PRESSURE DROP v’s FLOW Compatible with most general
Fluid
purpose hydraulic fluids
Viscosity = 32 cSt (150 SSU)
Seal Material Standard nitrile with PTFE back up rings
FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 Seal Kit Number SK1030 (Nitrile) SK1030V (Viton)
24
350
Mounting Position Unrestricted
20 300 Cartridge Weight 0.2 kg (0.4 lbs)
PRESSURE (BAR)

Coil Weight 0.3 kg (0.6 lbs)


PRESSURE (PSI)

16 240

Cavity Number A12743 (See Section 17)


12 180
Torque into Cavity 30 Nm (22 lbs ft)
8 120
Electrical Data See coil data sheet
4 60 Line Body Material Aluminium Alloy

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2211.A
PERFORMANCE PERFORMANCE
SELECTOR MODE NORMALLY CLOSED & NORMALLY OPEN MODES

SELECTOR MODE NORMALLY CLOSED & NORMALLY OPEN MODES

FLOW (US GPM) FLOW (US GPM)


1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625

WORKING PRESSURE (BAR)


WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900 200 2900
WORKING PRESSURE (PSI)

S520(H)
S520H
Normally open
150 2175 150 2175
S520

100 1450 100 1450


Normally closed
50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S520(H) BASIC CODE: S520(H)
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B18982
1/2” B19358 1/2” B19360
49.00
35.50 63.50
21.00
66.00

50.00

25.40 A/F
18.50
8.30

11
34.50

3
46.70

7/8"-14-UNF-2A 3
54.00

66.80

2
2

ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S520* N H 24 3W
Basic Code Port Sizes
S520 = (standard valve) 3W = 3/8” BSP
S520H = (heavy duty valve) 4W = 1/2” BSP 8T = 1/2” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-2212.B
S221(H) Directional Control Valve - 3-Way, 2-Position Spool

Up to 20 litres/min (5 US GPM)  Up to 210 bar (3000 PSI)

S221(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3  Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
APPLICATION

NORMALLY NORMALLY
CLOSED OPEN SELECTOR
(Pressure at Port 3) (Pressure at Port 1) (Pressure at Port 2) SPECIFICATIONS
ACTUATOR ACTUATOR
(2) (2) P (2)
Basic Model Code S221(std) / S221H (heavy duty)

2
T P P T ACT.1 ACT.2
(1) (3) (1) (3)
Symbol
(1) (3)
1 3

Actuator Port Location Port 2


COIL INFORMATION Max. Working Pressure 210 bar (3000 psi)

(See Page 11-1021) Flow Rating See performance graphs


Nominal Flow
Part Number: C13-*-*/14 (S221) 11 litres/min (3 US GPM)
11 C13-*-*/27 (S221H)
(at Delta P = 5 bar (70 psi))

Internal Leakage Less than 60 ml/min past each land


Voltage available: 12, 24 VDC 210 bar differential at 32 centistokes
110, 220 VAC* Temperature Range -20 to +120°C (-4 to +248°F)

* AC coils must be used with a rectifying connector. Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)

Fluid Compatible with most general


PRESSURE DROP v’s FLOW purpose hydraulic fluids
Viscosity = 32 cSt (150 SSU) Seal Material Standard nitrile with PTFE back up rings
FLOW US (GPM) Seal Kit Number SK973 (Nitrile) SK973V (Viton)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
15 210
Mounting Position Unrestricted
12 175 Cartridge Weight 0.13 kg (0.3 lbs)
PRESSURE (BAR)

PRESSURE (PSI)

1-2
130
Coil Weight 0.2 kg (0.4 lbs)
9
Cavity Number A3531 (See section 17)
6 90
3-2 Torque into Cavity 20 Nm (15 lbs ft)
3 45 Electrical Data See coil data sheet
0 0 Line Body Material Aluminium Alloy
0 2 4 6 8 10 12 14 16 18 20
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2311.A
PERFORMANCE PERFORMANCE
S221 (Standard valve) S221H (Heavy duty valve)

FLOW (US GPM) FLOW (US GPM)


0.5 1 1.5 2 2.5 3 3.5 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
250 250
NORMALLY OPEN 3625 NORMALLY OPEN 3625
NORMALLY CLOSED NORMALLY CLOSED
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)

WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900 200 2900

SELECTOR
150 2175 150 2175

SELECTOR
100 1450 100 1450

50 725 50 725

0 0 0 0
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 16 18 20
FLOW (LITRES/MIN)
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S221 / S221H BASIC CODE: S221 / S221H
Body ONLY part numbers
BSP, aluminium SAE, aluminium
48.00 1/4” B7724
3/8” B6684 3/8” B6516
23.50 36.00
57.20
38.50
55.50

11.10

14.70

24.00 A/F
28.30
9.55

3/4"-16-UNF-2A
3 2
3
11
38.10
44.00

63.50

2
1

2 HOLES
ø7.1 THRO'
ø14.20 1
28.60 12.70
ø15.80
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S221* N H 24 3W
Basic Code Port Sizes
S221 = (standard valve) 2W = 1/4” BSP
S221H = (heavy duty valve) 3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


1 = Push and twist H = DIN43650
2 = Screw F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2312.B
S521(H) Directional Control Valve - 3-Way, 2-Position Spool

Up to 44 litres/min (11.5 US GPM)  Up to 210 bar (3000 PSI)

S521(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.

1
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
2 3
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options
APPLICATION available.
 Sealed coil arrangement to protect stem from corrosion.
NORMALLY NORMALLY
CLOSED OPEN SELECTOR
(Pressure at Port 3) (Pressure at Port 1) (Pressure at Port 2) SPECIFICATIONS
ACTUATOR ACTUATOR
(2) (2) P (2)
Basic Model Code S521 / S521H
2
T P P T ACT.1 ACT.2
(1) (3) (1) (3) (1) (3)
Symbol
1 3

Actuator Port Location Port 2


COIL INFORMATION Max. Working Pressure
210 bar (3000 psi)
(See Page 11-1021) Flow Rating See performance graphs

Part Number: C16-*-*/19 (S521) Nominal flow


C16-*-*/29 (S521H) (at Delta P = 5 bar (70 psi)) 17 l/min

11 Voltage available: 12, 24 VDC


110, 220 VAC*
Internal Leakage
Less than 120 ml/min past each land
210 bar differential at 32 centistokes
Temperature Range
-20 to +120°C (-4 to +248°F)
* AC coils must be used with a rectifying connector.
Nominal Viscosity Range
15 to 250 centistokes
PRESSURE DROP v’s FLOW Recommended Filtration BS5540/4 18/13 (25 micron or better)
Viscosity = 32 cSt (150 SSU)
FLOW (US GPM)
Fluid Compatible with most general purpose
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 hydraulic fluids
18 260
Seal Material Standard nitrile with PTFE back up rings
15 210 Seal Kit Number SK1030 (Nitrile) SK1030V (Viton)
2-3 & 3-2
Mounting Position Unrestricted
PRESSURE (BAR)

PRESSURE (PSI)

12 175
Cartridge Weight 0.2 kg (0.4 lbs)
9 130
1-2 & 2-1 Coil Weight 0.3 kg (0.6 lbs)
6 90 Cavity Number A12743 (See section17)

45
Torque into Cavity 30 Nm (22 lbs ft)
3
Electrical Data See coil data sheet
0 0
0 5 10 15 20 25 30 35 40 Line Body Material Aluminium Alloy
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2411.A
PERFORMANCE PERFORMANCE
SELECTOR MODE NORMALLY CLOSED & NORMALLY OPEN MODES
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625
NORMALLY CLOSED
S521H
S521H

WORKING PRESSURE (PSI)


WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)


200 2900 200 2900

WORKING PRESSURE (PSI)


NORMALLY CLOSED
S521 S521
150 2175 150 2175

100 1450 100 1450


NORMALLY OPEN
S521(H)
50 725
50 725

0 0
0 0
0 5 10 15 20 25 30 35 40
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S521(H) BASIC CODE: S521(H)
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B18982
1/2” B19358 1/2” B19360
49.00
35.50 63.50
21.00
66.00

50.00

25.40 A/F
18.50
8.30

11
34.50

3
47.10

7/8"-14-UNF-2A 3
54.00

66.80

2
2
1
1
ø15.80
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S521* N H 24 3W
Basic Code Port Sizes
S521 = (standard valve) 3W = 3/8” BSP
S521H = (heavy duty valve) 4W = 1/2” BSP 8T = 1/2” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability) Coil Termination
2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on
request
We reserve the right to change specifications without notice

11-2412.B
S222 Directional Control Valve - 3-Way, 2-Position Spool

20 litres/min (5 US GPM)  Up to 100 bar (1500 PSI)

S222 FEATURES
 Increased flow capacity with low pressure drop.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.

2 3  Various coil terminals and voltages.


 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
APPLICATION

NORMALLY
CLOSED
(Pressure at Port 3) SPECIFICATIONS
ACTUATOR
(2) Basic Model Code S222
2
1 3
(T) (P) Symbol
1 3

Actuator Port Location Port 2


COIL INFORMATION Max. Working Pressure 100 bar (1500 psi)

(See Page 11-1021) Flow Rating 20 litres/min (5 US GPM)


Nominal Flow
Part Number: C13-*-*/14 17 litres/min (4.5 US GPM)
11 Voltage available: 12, 24 VDC
(at Delta P = 5 bar (70 psi))

Internal Leakage Less than 40 ml/min


110, 220 VAC* 100 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


* AC coils must be used with a rectifying connector.
Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)
PRESSURE DROP v’s FLOW
Fluid Compatible with most general
Viscosity = 32 cSt (150 SSU) purpose hydraulic fluids
Seal Material Standard nitrile with PTFE back up rings
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Seal Kit Number SK975 (Nitrile) SK975V (Viton)
12.5 181
NORMALLY
CLOSED ONLY Mounting Position Unrestricted
10.0 145
PRESSURE (BAR)

PRESSURE (PSI)

Cartridge Weight 0.13 kg (0.3 lbs)


7.5 109
Coil Weight 0.2 kg (0.4 lbs)
5.0 72
Cavity Number A18333 (See Section 17)
3-2 & 1-2
2.5 36 Torque into Cavity 20 Nm (15 lbs ft)

0 0 Electrical Data See coil data sheet


0 2 4 6 8 10 12 14 16 18 20
Line Body Material Aluminium Alloy
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2511.A
PERFORMANCE

FLOW (US GPM)


0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
125 1810
NORMALLY
CLOSED ONLY
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


100 1450

75 1090

50 725

25 360

0 0
0 2 4 6 8 10 12 14 16 18 20

FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S222 BASIC CODE: S222
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B7724
48.00
3/8” B6684 3/8” B6516
23.50 36.00
57.20
38.50
55.50

11.10

14.70

24.00 A/F
28.30
9.55

3/4"-16-UNF-2A 3
3 2
11
44.35

38.10

63.50

2
1

2 HOLES
ø7.1 THRO'
ø14.20 1
28.60 12.70
ø15.80
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S222 N H 24 3W
Basic Code Port Sizes
S222 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
1 = Push and twist Coil Termination
2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2512.B
S525(H) Directional Control Valve - 3-Way, 2-Position Spool

Up to 30 litres/min (8 US GPM)  Up to 210 bar (3000 PSI)

S525(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.

2 3  Various coil terminals and voltages.


 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
APPLICATION

NORMALLY NORMALLY SPECIFICATIONS


CLOSED OPEN SELECTOR
(Pressure at Port 1) (Pressure at Port 3) (Pressure at Port 2) S525 (std) / S525H (heavy duty)
Basic Model Code
ACTUATOR ACTUATOR
(2) (2) P (2) 2
Symbol
3 1
T P P T ACT.1 ACT.2
(3) (1) (3) (1) (3) (1) Actuator Port Location Port 2
Max. Working Pressure 210 bar (3000 psi)
Flow Rating See performance graphs
COIL INFORMATION
Nominal Flow
25 litres/min (6.5 US GPM)
(See Page 11-1021) (at Delta P = 5 bar (70 psi))

Part Number: C16-*-*/19 (S525) Less than 120 ml/min


Internal Leakage

11 C16-*-*/29 (S525H)
Temperature Range
210 bar differential at 32 centistokes

-20 to +120°C (-4 to +248°F)


Voltage available: 12, 24 VDC
Nominal Viscosity Range 15 to 250 centistokes
110, 220 VAC*
Recommended Filtration BS5540/4 18/13 (25 micron or better)
* AC coils must be used with a rectifying connector.
Fluid Compatible with most general
purpose hydraulic fluids

Seal Material Standard nitrile with PTFE back up rings


PRESSURE DROP v’s FLOW
Seal Kit Number SK1030 (Nitrile) SK1030V (Viton)
Viscosity = 32 cSt (150 SSU) Mounting Position Unrestricted
FLOW (US GPM)

50
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 Cartridge Weight 0.2 kg (0.4 lbs)
Coil Weight 0.3 kg (0.6 lbs)
600
40
Cavity Number A12743 (See Section 17)
PRESSURE (BAR)

PRESSURE (PSI)

30
400
Torque into Cavity 30 Nm (22 lbs ft)

20
Electrical Data See coil data sheet
200 Line Body Material Aluminium Alloy
10

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2611.A
PERFORMANCE PERFORMANCE
S525 (Standard valve) S525H (Heavy duty valve)
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625
NORMALLY OPEN NORMALLY OPEN
WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)


WORKING PRESSURE (PSI)

WORKING PRESSURE (PSI)


200 2900 200 2900

150 2175 150 2175


SELECTOR NORMALLY CLOSED SELECTOR
100 1450 100 1450

50 725 50 725
NORMALLY CLOSED
0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S525 / S525H BASIC CODE: S525 / S525H
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B18982
1/2” B19358 1/2” B19360
49.00
35.50 63.50
21.00
66.00

50.00

25.40 A/F
18.50
8.30

34.50

3
46.70

11
7/8"-14-UNF-2A 3
54.00

66.80

2
2

1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S525* N H 24 3W
Basic Code Port Sizes
S525 = (standard valve) 3W = 3/8” BSP
S525H = (heavy duty valve) 4W = 1/2” BSP 8T = 1/2” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2612.B
S526 Directional Control Valve - 3-Way, 2-Position Spool

Up to 35 litres/min (9 US GPM)  Up to 210 bar (3000 PSI)

S526 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.

1 (TANK)  Various coil terminals and voltages.


 Coil interchangeability with all Series S5 valves.
2 3
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS

Basic Model Code S526


T (1)

Symbol
COIL INFORMATION
2 3
(See Page 11-1021) Max. Working Pressure 210 bar (3000 psi)
Flow Rating See performance graphs
Part Number: C16-*-*/19
Nominal Flow
11 litres/min (3 US GPM)
Voltage available: 12, 24 VDC (at Delta P = 5 bar (70 psi))
110, 220 VAC*
Internal Leakage Less than 120 ml/min past each land
* AC coils must be used with a rectifying connector. 210 bar differential at 32 centistokes

11 Temperature Range -20 to +120°C (-4 to +248°F)


Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)

Fluid Compatible with most general


PRESSURE DROP v’s FLOW purpose hydraulic fluids
Seal Material Standard nitrile with PTFE back up rings
Viscosity = 32 cSt (150 SSU)
Seal Kit Number SK1030 (Nitrile) SK1030V (Viton)
FLOW (US GPM) Mounting Position Unrestricted
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
50
Cartridge Weight 0.2 kg (0.4 lbs)
600 Coil Weight 0.3 kg (0.6 lbs)
40
PRESSURE (BAR)

PRESSURE (PSI)

3-2 & 2-3 Cavity Number A12743 (See Section 17)


30
400
Torque into Cavity 30 Nm (22 lbs ft)
20
Electrical Data See coil data sheet
All other flow paths 200
10 Line Body Material Aluminium Alloy

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2711.A
PERFORMANCE
FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625
3-1 & 2-1
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900
1-2 & 1-3
3-2
150 2175

2-3
100 1450

50 725

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S526 BASIC CODE: S526
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B18982
1/2” B19358 1/2” B19360
49.00
35.50 63.50
21.00
66.00

50.00

25.40 A/F
18.50
8.30

34.50

3
46.70

7/8"-14-UNF-2A 3
54.00

11
66.80

2
2

ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S526 N H 24 3W
Basic Code Port Sizes
S526 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
2 = Screw
Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2712.B
S228 Directional Control Valve - 3-Way, 2-Position Spool

15 litres/min (4 US GPM)  Up to 50 bar (725 PSI)

S228 FEATURES
 Increased flow capacity with low pressure drop.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.
 Various coil terminals and voltages.
2 3  Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
APPLICATION

NORMALLY
CLOSED
(Pressure at Port 2) SPECIFICATIONS
ACTUATOR
1
Basic Model Code S228
1

3 2
(T) (P)
Symbol
3 2

Actuator Port Location Port 1


COIL INFORMATION Max. Working Pressure 50 bar (750 psi)
(See Page 11-1021) Flow Rating 15 litres/min (4 US GPM)
Nominal Flow
Part Number: C13-*-*/14 15 litres/min (4 US GPM)
11 Voltage available: 12, 24 VDC
(at Delta P = 5 bar (70 psi))

Internal Leakage Less than 60 ml/min


110, 220 VAC* 50 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


* AC coils must be used with a rectifying connector.
Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)
PRESSURE DROP v’s FLOW
Fluid Compatible with most general
Viscosity = 32 cSt (150 SSU) purpose hydraulic fluids
Seal Material Standard nitrile with PTFE back up rings
FLOW (US GPM)
1 2 3 4 Seal Kit Number SK975 (Nitrile) SK975V (Viton)
15 210
Mounting Position Unrestricted
12 175
PRESSURE (BAR)

Cartridge Weight 0.13 kg (0.3 lbs)


PRESSURE (PSI)

9 130
Coil Weight 0.2 kg (0.4 lbs)
6 90 Cavity Number A18333 (See Section 17)

3 45
Torque into Cavity 20 Nm (15 lbs ft)
1-3 2-1
Electrical Data See coil data sheet
0 0
0 4 8 12 16 Line Body Material Aluminium Alloy
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2721.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4 4.5
125 1810
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


100 1450

75 1090

50 725

25 360

0 0 0
0 2 4 6 8 10 12 14 16 18
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S228 BASIC CODE: S228
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B7724
48.00 3/8” B6684 3/8” B6516

23.50 36.00
57.20
38.50
55.50

11.10

14.70

24.00 A/F
28.30
9.55

3
3/4"-16-UNF-2A
2
11
38.10

3
63.50
44.35

2
1

2 HOLES
ø7.1 THRO'
ø14.20 1
28.60 12.70
ø15.80 4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S228 N H 24 3W
Basic Code Port Sizes
S228 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2722.B
S229 Directional Control Valve - 3-Way, 2-Position Poppet

Up to 12 litres/min (3 US GPM)  Up to 210 bar (3000 PSI)

S229 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.

2 3  One-piece encapsulated coil with minimal amperage draw.

1  Oil immersed armature solenoid.


 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION SPECIFICATIONS

Basic Model Code S229


(See Page 11-1021)
ACT 2
Symbol
Part Number: C16-*-*/29
T1 P3

Voltage available: 12, 24 VDC Actuator Port Location Port 2


110, 220 VAC*
Max. Working Pressure 210 bar (3000 psi)
* AC coils must be used with a rectifying connector. Flow Rating See performance graphs
Nominal Flow
10 litres/min (2.6 US GPM)
11 (at Delta P = 5 bar (70 psi))

Internal Leakage Less than 0.6 ml/min (10 dpm)


210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


PRESSURE DROP v’s FLOW
Nominal Viscosity Range 15 to 250 centistokes
Viscosity = 32 cSt (150 SSU)
Recommended Filtration BS5540/4 18/13 (25 micron or better)

Fluid Compatible with most general


purpose hydraulic fluids
FLOW US (GPM)
1 2 3 4 5 6 750
50 Seal Material Standard nitrile with PTFE back up rings
600 Seal Kit Number SK119 (Nitrile) SK119V (Viton)
40
PRESSURE (BAR)

PRESSURE (PSI)

Mounting Position Unrestricted


450
30
Cartridge Weight 0.13 kg (0.3 lbs)
3-2 300
20 Coil Weight 0.3 kg (0.6 lbs)
2-1
10 150 Cavity Number A3531 (See section 17)
Torque into Cavity 30 Nm (22 lbs ft)
0 0
0 5 10 15 20 25
Electrical Data See coil data sheet
FLOW (LITRES/MIN)
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2731.A
PERFORMANCE
FLOW (US GPM)

1.25 2.5 3.75 5 6.25


250

3-2
WORKING PRESSURE (BAR)
3000

WORKING PRESSURE (PSI)


200

150
2000

100
1000
2-1
50

0 0
0 5 10 15 20 25

FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S229 BASIC CODE: S229
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B7724
49.00 3/8” B6684 3/8” B6516
35.50
21.00
57.20
72.00

50.00

11.10

14.70

24.00 A/F

11
28.30
9.55

3/4"-16-UNF-2A
3
2
38.10

3
63.50
44.00

2
1

2 HOLES
ø7.1 THRO'
ø14.20 1
28.60 12.70
ø15.80 4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S229 N H 24 3W
Basic Code Port Sizes
S229 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


2 = Screw H = DIN43650
3 = Push F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2732.B
S240 Directional Control Valve - 4-Way, 2-Position Spool

Up to 18 litres/min (4.7 US GPM)  Up to 210 bar (3000 PSI)

S240 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.

1  One-piece encapsulated coil with minimal amperage draw.


 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION  Reversible coil without affecting performance.

(See Page 11-1021)

Part Number: C13-*-*/14


SPECIFICATIONS
Voltage available: 12, 24 VDC
110, 220 VAC*
Basic Model Code S240
* AC coils must be used with a rectifying connector. A (2) B (4)

Symbol
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating 18 litres/min (4.7 US GPM)
PRESSURE DROP v’s FLOW Nominal flow
10 litres/min (2.5 US GPM)
(at Delta P = 5 bar (70 psi))
Viscosity = 32 cSt (150 SSU)
Less than 60 ml/min past each land
11 Internal Leakage
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM) Nominal Viscosity Range 15 to 250 centistokes
0.5 1 1.5 2 2.5 3 3.5 4 4.5
15.0 Recommended Filtration BS5540/4 18/13 (25 micron or better)
218
Compatible with most general
12.5 181 Fluid
purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

10.0 145 Seal Material Viton with PTFE back up rings

7.5 109 Seal Kit Number SK974 (Nitrile) SK974V (Viton)


Mounting Position Unrestricted
5.0 72
Cartridge Weight 0.13 kg (0.3 lbs)
2.5 36
Coil Weight 0.2 kg (0.4 lbs)
0 Cavity Number A6951 (See Section 17)
0 2 4 6 8 10 12 14 16 18
FLOW (LITRES/MIN) Torque into Cavity 20 Nm (15 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2811.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16 18 20

FLOW (LITRES/MIN)

ALL FLOW PATHS

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS

BASIC CODE: S240 BASIC CODE: S240


Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
48.00 3/8” B7498 3/8” B19362
23.50 36.00 57.20
55.50

38.50

14.10
11.00

24.00 A/F
9.55

28.50

3/4"-16-UNF-2A
4
42.70

4
54.00

3
3
50.80

76.20

2
2
11
1 2 HOLES 1
ø12.60
ø7.1 THRO'
ø14.20

ø15.80 28.60 12.70


4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S240 N H 24 3W
Basic Code Port Sizes
S240 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


1 = Push and twist H = DIN43650
2 = Screw F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2812.B
S241 Directional Control Valve - 4-Way, 2-Position Spool

Up to 20 litres/min (5 US GPM)  Up to 210 bar (3000 PSI)

S241 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
 Reversible coil without affecting performance.
COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/14


SPECIFICATIONS
Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S241
A (2) B (4)
* AC coils must be used with a rectifying connector.
Symbol
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs
PRESSURE DROP v’s FLOW Nominal flow
11 litres/min (3 US GPM)
(at Delta P = 5 bar (70 psi))
Viscosity = 32 cSt (150 SSU)
Less than 60 ml/min past each land
11 Internal Leakage
210 bar differential at 32 centistokes

FLOW (US GPM)


Temperature Range -20 to +120°C (-4 to +248°F)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 Nominal Viscosity Range 15 to 250 centistokes
15.0 218
Recommended Filtration BS5540/4 18/13 (25 micron or better)
12.5 181
Compatible with most general
3-4 Fluid
purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

10.0 145

Seal Material Viton with PTFE back up rings


7.5 109
Seal Kit Number SK974 (Nitrile) SK974V (Viton)
5.0 72
Mounting Position Unrestricted
2-1
2.5 36 Cartridge Weight 0.13 kg (0.3 lbs)
Coil Weight 0.2 kg (0.4 lbs)
0 0
0 2 4 6 8 10 12 14 16 18 Cavity Number A6951 (See Section 17)
FLOW (LITRES/MIN)
Torque into Cavity 20 Nm (15 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-2911.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
250 3625
3-4 AND 2-1
200 2900
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


150 2175
3-4
OR
2-1
100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16 18 20
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS

BASIC CODE: S241 BASIC CODE: S241


Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
48.00 3/8” B7498 3/8” B19362
23.50 36.00 57.20
55.50

38.50

14.10
11.00

24.00 A/F
9.55

28.50

3/4"-16-UNF-2A
4
42.70

4
54.00

3
3

11
50.80

76.20

2
2

1 2 HOLES 1
ø12.60
ø7.1 THRO'
ø14.20

ø15.80 28.60 12.70


4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S241 N H 24 3W
Basic Code Port Sizes
S241 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
1 = Push and twist Coil Termination
2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-2912.B
S541 Directional Control Valve - 4-Way, 2-Position Spool

Up to 30 litres/min (8 US GPM)  Up to 210 bar (3000 PSI)

S541 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4  Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
 Reversible coil without affecting performance.
COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19


SPECIFICATIONS
Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S541
A (2) B (4)
* AC coils must be used with a rectifying connector.
Symbol
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs
PRESSURE DROP v’s FLOW Nominal flow
20 litres/min (5 US GPM)
(at Delta P = 5 bar (70 psi))
Viscosity = 32 cSt (150 SSU)
Less than 120 ml/min
11 FLOW (US GPM)
Internal Leakage
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


1 2 3 4 5 6 7 8
15.0 218 Nominal Viscosity Range 15 to 250 centistokes
12.5 181 Recommended Filtration BS5540/4 18/13 (25 micron or better)
3-4
PRESSURE (BAR)

Compatible with most general


PRESSURE (PSI)

10.0 145
Fluid
purpose hydraulic fluids
7.5 109
Seal Material Viton with PTFE back up rings
5.0 72 Seal Kit Number SK1031 (Nitrile) SK1031V (Viton)
2-1
36
Mounting Position Unrestricted
2.5
Cartridge Weight 0.13 kg (0.3 lbs)
0 0
0 4 8 1216 20 24 28 32 Coil Weight 0.3 kg (0.6 lbs)
FLOW (LITRES/MIN)
Cavity Number A12744 (See page 11-441)
Torque into Cavity 30 Nm (22 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3011.A
PERFORMANCE

FLOW (US GPM)

1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4


250 3625
3-4 AND 2-1
OR 2-1
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450
3-4

50 725

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS

BASIC CODE: S541 BASIC CODE: S541


Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
35.50 63.50
21.00
66.00

50.00

25.40 A/F
18.50
8.30

34.50

4
50.50

7/8"-14-UNF-2A 4
62.50

11
3
73.20

82.60

2
2
1
1
ø15.80
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S541 N H 24 3W
Basic Code Port Sizes
S541 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
1 = Push and twist Coil Termination
2 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3012.B
S242(H) Directional Control Valve - 4-Way, 2-Position Spool

Up to 15 litres/min (4 US GPM)  Up to 210 bar (3000 PSI)

S242(H) FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.
 Various coil terminals and voltages.
2 3 4
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
 Reversible coil without affecting performance.

COIL INFORMATION
SPECIFICATIONS
(See Page 11-1021)

Part Number: C13-*-*/14 (S242) Basic Model Code S242 (std) / S242H (heavy duty)
C13-*-*/27 (S242H) A (2) B (4)

Voltage available: 12, 24 VDC Symbol


110, 220 VAC* P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


* AC coils must be used with a rectifying connector.
Flow Rating See performance graphs

Nominal Flow
(at Delta P = 5 bar (70 psi)) 11 litres/min (3 US GPM)

11 PRESSURE DROP v’s FLOW Internal Leakage Less than 60 ml/min past each land
210 bar differential at 32 centistokes
Viscosity = 32 cSt (150 SSU)
Temperature Range -20 to +120°C (-4 to +248°F)
Nominal Viscosity Range 15 to 250 centistokes
Recommended Filtration BS5540/4 18/13 (25 micron or better)

FLOW (US GPM)


Fluid Compatible with most general
0.5 1 1.5 2 2.5 3 3.5 4 purpose hydraulic fluids
12.5 181
Seal Material Standard nitrile with PTFE back up rings
10.0 145 Seal Kit Number SK974 (Nitrile) SK974V (Viton)
PRESSURE (BAR)

3-2, 4-1 & 3-4 Mounting Position Unrestricted


PRESSURE (PSI)

7.5 109
Cartridge Weight 0.13 kg (0.3 lbs)

5.0 72 Coil Weight 0.2 kg (0.4 lbs)


2-1 Cavity Number A6951 (See Section 17)
2.5 36
Torque into Cavity 20 Nm (15 lbs ft)

0 0
Electrical Data See coil data sheet
0 2 4 6 8 10 12 14 16 Line Body Material Aluminium Alloy
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3111.A
PERFORMANCE PERFORMANCE
S242 (Standard valve) S242H (Heavy duty valve)
FLOW (US GPM) FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4 0.5 1 1.5 2 2.5 3 3.5 4
250 3625 250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


WORKING PRESSURE (PSI)

WORKING PRESSURE (BAR)


200 2900 200 2900

150 2175 150 2175

100 1450 100 1450

50 725 50 725

0 0 0 0
0 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN) ALL FLOW PATHS FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE


1/4” 3/8” PORTS
BASIC CODE: S242 / S242H BASIC CODE: S242 / S242H
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
48.00 3/8” B7498 3/8” B19362

23.50 36.00 57.20


55.50

38.50

14.10
11.00

24.00 A/F
9.55

28.50

3/4"-16-UNF-2A
4
42.70

4
54.00

3
3

11
50.80

76.20

2
2

1 2 HOLES 1
ø12.60
ø7.1 THRO'
ø14.20

ø15.80 28.60 12.70


4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S242* N H 24 3W
Basic Code Port Sizes
S242 = (standard valve) 2W = 1/4” BSP
S242H = (heavy duty valve) 3W = 3/8” BSP 6T = 3/8” SAE

Seals Voltage
N = Nitrile 12 = 12 VDC 110 = 110 VAC
V = Viton 24 = 24 VDC 220 = 220 VAC

Manual Override (consult factory for availability) Coil Termination


1 = Push and twist H = DIN43650
2 = Screw F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3112.B
S542 Directional Control Valve - 4-Way, 2-Position Spool

Up to 35 litres/min (9 US GPM)  Up to 210 bar (3000 PSI)

S542 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.

1
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION  Reversible coil without affecting performance.

(See Page 11-1021)

Part Number: C16-*-*/19


SPECIFICATIONS
Voltage available: 12, 24 VDC
110, 220 VAC*
Basic Model Code S542
* AC coils must be used with a rectifying connector. A (2) B (4)

Symbol
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs
PRESSURE DROP v’s FLOW
Nominal flow
Viscosity = 32 cSt (150 SSU) 20 litres/min (5 US GPM)
(at Delta P = 5 bar (70 psi))

11 FLOW (US GPM)


Internal Leakage Less than 120 ml/min past each land
210 bar differential at 32 centistokes

1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 Temperature Range -20 to +120°C (-4 to +248°F)
25 365
Nominal Viscosity Range 15 to 250 centistokes

20 280 Recommended Filtration BS5540/4 18/13 (25 micron or better)


2-1
Fluid Compatible with most general
PRESSURE (BAR)

PRESSURE (PSI)

15 215 purpose hydraulic fluids

Seal Material Standard nitrile with PTFE back up rings


10 145
Seal Kit Number SK1031 (Nitrile) SK1031V (Viton)
3-2, 4-1 & 3-4
5 70 Mounting Position Unrestricted
Cartridge Weight 0.205 kg (0.45 lbs)
0 0
0 5 10 15 20 25 30 35 40 Coil Weight 0.3 kg (0.6 lbs)
FLOW (LITRES/MIN) Cavity Number A12744 (See Section 17)
Torque into Cavity 30 Nm (22 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3211.A
PERFORMANCE
FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1
250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 3-2 AND 4-1 2900
OR
3-4 AND 2-1
150 2175

100 1450

50 725

0 0
0 5 10 15 20 25 30 35
FLOW (LITRES/MIN)
NOTE:
For applications were unbalanced pressure and return flows are encountered the flow rate of this valve should be reduced, please
contact our sales office for details.

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S542 BASIC CODE: S542
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
21.00 35.50 63.50
66.00

50.00

25.40 A/F
8.30

18.50
34.50

7/8"-14-UNF-2A 4
4
50.50
62.50

11
3
73.20

3
82.60

2
2
1
1
ø15.80
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00
6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S542 N H 24 3W
Basic Code Port Sizes
S542 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
2 = Screw Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on
We reserve the right to change specifications without notice request

11-3212.B
S270 Directional Control Valve - 4-Way, 3-Position Spool

Up to 13 litres/min (3.5 US GPM)  Up to 210 bar (3000 PSI)

S270 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B  Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.

2 3 4  Various coil terminals and voltages.


 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/22 (two per valve) SPECIFICATIONS


Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S270
A (2) B (4)
* AC coils must be used with a rectifying connector.
Symbol
B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating 13 litres/min (3.5 US GPM)
Nominal Flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
8 litres/min (2 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage Less than 100 ml/min past each land
210 bar differential at 32 centistokes

FLOW (US GPM) Temperature Range -20 to +120°C (-4 to +248°F)


0.5 1 1.5 2 2.5 3 3.5 4 Nominal Viscosity Range 15 to 250 centistokes
18 260
Recommended Filtration BS5540/4 18/13 (25 micron or better)
15 210
Fluid Compatible with most general
purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

12 145

3-4 & 3-2 Seal Material Standard nitrile with PTFE back up rings
9 130
Seal Kit Number SK974 (Nitrile) SK974V (Viton)
Mounting Position Unrestricted
6 90
Cartridge Weight 0.16 kg (0.35 lbs)
2-1 & 4-1
3 45
Coil Weight 0.2 kg (0.4 lbs) - two per valve

0 0
Cavity Number A6951 (See Section 17)
0 2 4 6 8 10 12 14 16
Torque into Cavity 20 Nm (15 lbs ft)
FLOW (LITRES/MIN)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3311.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4
250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S270 BASIC CODE: S270
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
48.00 3/8” B7498 3/8” B19362
23.50 36.00 57.20
38.50
102.00

38.50

11.00

14.10

24.00 A/F
11.50

28.50

42.70

11
3/4"-16-UNF-2A 4
54.00

4
50.80

3
76.20

3
2
2
1
1 2 HOLES
ø12.60
ø7.1 THRO'
ø14.20
ø15.80 28.60 12.70
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S270 N H 24 3W
Basic Code Port Sizes
S270 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3312.B
S570 Directional Control Valve - 4-Way, 3-Position Spool

Up to 35 litres/min (9 US GPM)  Up to 210 bar (3000 PSI)

S570 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B  Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19 (two per valve) SPECIFICATIONS


Voltage available: 12, 24 VDC
Basic Model Code S570
110, 220 VAC*
A (2) B (4)
* AC coils must be used with a rectifying connector. Symbol
B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs

Nominal flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
22 litres/min (5.8 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage
Less than 120 ml/min
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM)
Nominal Viscosity Range 15 to 250 centistokes
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
25 365 Recommended Filtration BS5540/4 18/13 (25 micron or better)

280 Fluid Compatible with most general


20
purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

15 215 Seal Material Viton with PTFE back up rings


3-2 & 3-4
Seal Kit Number SK1034 (Nitrile) SK1034V (Viton)
10 145
Mounting Position Unrestricted

5 70
Cartridge Weight 0.25 kg (0.55 lbs)
2-1 & 4-1
Coil Weight 0.3 kg (0.6 lbs) - two per valve
0 0 Cavity Number A12744 (See Section 17)
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) Torque into Cavity 30 Nm (22 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3411.A
PERFORMANCE PERFORMANCE
FLOWING BACK THROUGH THE VALVE FLOWING IN ONE DIRECTION ONLY
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625
3-2-4-1 & 3-4-2-1

WORKING PRESSURE (BAR)


WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


WORKING PRESSURE (PSI)
200 2900 200 2900

150 2175 150 2175


3-2
3-4
100 1450 100 1450

50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS

BASIC CODE: S570 BASIC CODE: S570


Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
49.00 1/2” B19228 1/2” B19229
21.00 35.50 63.50
50.00
125.00

50.00

11
18.50
12.00

27.00 A/F
34.50

4
50.50

7/8"-14-UNF-2A 4
62.50

3
73.20

3
82.60

2
2
1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S570 N H 24 3W
Basic Code Port Sizes
S570 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3412.B
S271 Directional Control Valve - 4-Way, 3-Position Spool

Up to 14 litres/min (3.7 US GPM)  Up to 210 bar (3000 PSI)

S271 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/22 (two per valve) SPECIFICATIONS


Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S271
A (2) B (4)
* AC coils must be used with a rectifying connector. Symbol
B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating 14 litres/min (3.7 US GPM)

Nominal Flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
8 litres/min (2 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage Less than 100 ml/min past each land
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM) Nominal Viscosity Range 15 to 250 centistokes
0.5 1 1.5 2 2.5 3 3.5 4
18 260 Recommended Filtration BS5540/4 18/13 (25 micron or better)
Compatible with most general
15 210 Fluid
purpose hydraulic fluids
2-1 & 4-1
PRESSURE (BAR)

12 145 Seal Material Standard nitrile with PTFE back up rings


PRESSURE (PSI)

3-4 & 3-2 Seal Kit Number SK974 (Nitrile) SK974V (Viton)
9 130
Mounting Position Unrestricted

6 90 Cartridge Weight 0.16 kg (0.35 lbs)


Coil Weight 0.2 kg (0.4 lbs) - two per valve
3 45
Cavity Number A6951 (See Section 17)
2-1 & 4-1 centre position
0 0 Torque into Cavity 20 Nm (15 lbs ft)
0 2 4 6 8 10 12 14 16
Electrical Data See coil data sheet
FLOW (LITRES/MIN)
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3511.A
PERFORMANCE
FLOW (US GPM)

0.5 1 1.5 2 2.5 3 3.5 4


250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S271 BASIC CODE: S271
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
3/8” B7498 3/8” B19362
48.00 57.20
23.50 36.00
38.50
102.00

38.50

11.00

14.10

24.00 A/F
28.50
11.50

42.70

3/4"-16-UNF-2A 4
4
11
54.00

50.80

76.20

3
3
2
2
1
2 HOLES
1 ø7.1 THRO'
ø12.60
ø14.20 28.60 12.70
ø15.80 4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S271 N H 24 3W
Basic Code Port Sizes
S271 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3512.B
S571 Directional Control Valve - 4-Way, 3-Position Spool

Up to 34 litres/min (8.7 US GPM)  Up to 210 bar (3000 PSI)

S571 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19 (two per valve) SPECIFICATIONS


Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S571
A (2) B (4)
* AC coils must be used with a rectifying connector. Symbol
B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs

Nominal Flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
18 litres/min (4.7 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage Less than 120 ml/min past each land
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM)
Nominal Viscosity Range 15 to 250 centistokes
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
15
3-2 & 3-4
210 Recommended Filtration BS5540/4 18/13 (25 micron or better)
2-1 & 4-1
Compatible with most general
12 175 Fluid
purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

9 130 Seal Material Standard nitrile with PTFE back up rings


3-1, 2-1 & 4-1 Seal Kit Number SK1034 (Nitrile) SK1034V (Viton)
6 90
Mounting Position Unrestricted

3 45 Cartridge Weight 0.25 kg (0.5 lbs)


Coil Weight 0.3 kg (0.6 lbs) - two per valve
0 0
0 5 10 15 20 25 30 35 40
Cavity Number A12744 (See Section 17)
FLOW (LITRES/MIN) Torque into Cavity 30 Nm (22 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3611.A
PERFORMANCE PERFORMANCE
FLOWING BACK THROUGH THE VALVE FLOWING IN ONE DIRECTION ONLY
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


WORKING PRESSURE (PSI)
200 2900 200 2900
3-2-4-1 & 3-4-2-1

150 2175 150 2175


3-2 3-4
100 1450 100 1450

50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

NOTE: Higher flows available on request

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S571 BASIC CODE: S571
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
21.00 35.50 63.50
50.00
125.00

50.00

11
18.50
12.00

27.00 A/F
34.50

4
50.50

7/8"-14-UNF-2A 4
62.50

3
73.20

3
82.60

2
2
1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


S571 N H 24 3W
Basic Code Port Sizes
S571 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-3612.B
S272 Directional Control Valve - 4-Way, 3-Position Spool

Up to 14 litres/min (3.7 US GPM)  Up to 210 bar (3000 PSI)

S272 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.
2 3 4  Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)
SPECIFICATIONS
Part Number: C13-*-*/22 (two per valve)
Basic Model Code S272
Voltage available: 12, 24 VDC
110, 220 VAC* A (2) B (4)

Symbol
* AC coils must be used with a rectifying connector. B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating 14 litres/min (3.7 US GPM)
Nominal flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
8 litres/min (2 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage Less than 60 ml/min
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM) Nominal Viscosity Range 15 to 250 centistokes
0.5 1 1.5 2 2.5 3 3.5 4
18 260 Recommended Filtration BS5540/4 18/13 (25 micron or better)

15 210 Fluid Compatible with most general


2-1 & 4-1 purpose hydraulic fluids
PRESSURE (BAR)

PRESSURE (PSI)

12 145 Seal Material Standard nitrile with PTFE back up rings


3-4 & 3-2
130
Seal Kit Number SK974 (Nitrile) SK974V (Viton)
9
Mounting Position Unrestricted
6 90
Cartridge Weight 0.16 kg (0.35 lbs)
2-1 centre position
3 45 Coil Weight 0.2 kg (0.4 lbs) - two per valve
Cavity Number A6951 (See Section 17)
0 0
0 2 4 6 8 10 12 14 16 Torque into Cavity 20 Nm (15 lbs ft)
FLOW (LITRES/MIN)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3711.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4
250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S272 BASIC CODE: S272
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
3/8” B7498 3/8” B19362
48.00
23.50 36.00 57.20
38.50
102.00

38.50

11.00

14.10

24.00 A/F
11.50

28.50

11
42.70

3/4"-16-UNF-2A 4
54.00

4
50.80

3
76.20

3
2
2
1
1 2 HOLES
ø12.60
ø7.1 THRO'
ø14.20
ø15.80 28.60 12.70
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S272 N H 24 3W
Basic Code Port Sizes
S272 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-3712.B
S572 Directional Control Valve - 4-Way, 3-Position Spool

Up to 34 litres/min (8.7 US GPM)  Up to 210 bar (3000 PSI)

S572 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
2 3 4
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)
SPECIFICATIONS
Part Number: C16-*-*/19 (two per valve)
Basic Model Code S572
Voltage available: 12, 24 VDC
110, 220 VAC* A (2) B (4)

Symbol
* AC coils must be used with a rectifying connector. B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating See performance graphs
Nominal flow
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))
18 litres/min (4.7 US GPM)

Viscosity = 32 cSt (150 SSU)


11 Internal Leakage Less than 120 ml/min past each land
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


FLOW (US GPM)
1.3 3.9 5.2 6.5 7.8 9.1 10.4
Nominal Viscosity Range 15 to 250 centistokes
2.6
15 210
3-2 & 3-4 Recommended Filtration BS5540/4 18/13 (25 micron or better)
2-1 & 4-1
12 175
Fluid Compatible with most general
PRESSURE (PSI)
PRESSURE (BAR)

purpose hydraulic fluids


9 130
Seal Material Standard nitrile with PTFE back up rings
3-1, 2-1 & 4-1
6 90 Seal Kit Number SK1034 (Nitrile) SK1034V (Viton)
Mounting Position Unrestricted
3 45
Cartridge Weight 0.25 kg (0.5 lbs)
0 0 Coil Weight 0.3 kg (0.6 lbs) - two per valve
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)
Cavity Number A12744 (See Section 17)
Torque into Cavity 30 Nm (22 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3811.C
PERFORMANCE PERFORMANCE
FLOWING BACK THROUGH THE VALVE FLOWING IN ONE DIRECTION ONLY
FLOW (US GPM) FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
250 3625 250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)

WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900 200 2900
3-2-4-1 & 3-4-2-1

150 2175 150 2175


3-2 3-4
100 1450 100 1450

50 725 50 725

0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN) FLOW (LITRES/MIN)

NOTE: Higher flows available on request

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S572 BASIC CODE: S572
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
21.00 35.50 63.50
50.00
125.00

50.00

11
18.50
12.00

27.00 A/F
34.50

4
50.50

7/8"-14-UNF-2A 4
62.50

3
73.20

3
82.60

2
2
1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


S572 N H 24 3W
Basic Code Port Sizes
S572 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on request

11-3812.B
S274 Directional Control Valve - 4-Way, 3-Position Spool

14 litres/min (3.7 US GPM)  Up to 210 bar (3000 PSI)

S274 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
COIL A COIL B
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1  Oil immersed armature solenoid.

2 3 4  Various coil terminals and voltages.


 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/22 (two per valve)

Voltage available: 12, 24 VDC SPECIFICATIONS


110, 220 VAC*
Basic Model Code S274
* AC coils must be used with a rectifying connector.
A (2) B (4)

Symbol
B A
PRESSURE DROP v’s FLOW P (3) T (1)

Viscosity = 32 cSt (150 SSU) Max. Working Pressure 210 bar (3000 psi)
Flow Rating 14 litres/min (3.7 US GPM)
SPOOL SHIFTED
FLOW (US GPM) Nominal flow
12 litres/min (3.2 US GPM)
10
0.5 1 1.5 2 2.5 3
150
(at Delta P = 5 bar (70 psi))

11 8 120 Internal Leakage Less than 60 ml/min


210 bar differential at 32 centistokes
PRESSURE (BAR)

PRESSURE (PSI)

3-2 or 3-4
6 90
2-1 Temperature Range -20 to +120°C (-4 to +248°F)
4 60 Nominal Viscosity Range 15 to 250 centistokes
4-1 Recommended Filtration BS5540/4 18/13 (25 micron or better)
2 30

Fluid Compatible with most general


0 0
0 2 4 6 8 10 12 purpose hydraulic fluids
FLOW (LITRES/MIN)
Seal Material Standard nitrile with PTFE back up rings
SPOOL CENTRED Seal Kit Number SK974 (Nitrile) SK974V (Viton)
FLOW (US GPM)

10
0.5 1 1.5 2 2.5 3
150
Mounting Position Unrestricted
Cartridge Weight 0.16 kg (0.35 lbs)
8 120
Coil Weight 0.2 kg (0.4 lbs) - two per valve
PRESSURE (BAR)

PRESSURE (PSI)

6 90 Cavity Number A6951 (See Section 17)


4-1
4 60 Torque into Cavity 20 Nm (15 lbs ft)
2-1 Electrical Data See coil data sheet
2 30
Line Body Material Aluminium Alloy
3-1
0 0
0 2 4 6 8 10 12
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-3911.A
PERFORMANCE
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 3.5 4
WORKING PRESSURE (BAR) 250 3625

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S274 BASIC CODE: S274
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
48.00 3/8” B7498 3/8” B19362
23.50 36.00 57.20
38.50
102.00

38.50

11.00

14.10

24.00 A/F
11.50

28.50

42.70

3/4"-16-UNF-2A 4

11
54.00

4
50.80

3
76.20

3
2
2
1
ø12.60 1 2 HOLES
ø7.1 THRO'
ø14.20
ø15.80 28.60 12.70
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S274 N H 24 3W
Basic Code Port Sizes
S274 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-3912.B
S574 Directional Control Valve - 4-Way, 3-Position Spool

Up to 34 litres/min (8.7 US GPM)  Up to 210 bar (3000 PSI)

S574 FEATURES
 High flow capacity with reduced space requirements.
COIL A COIL B  No dynamic seals.
 Standard valve bodies and common cavities.

1  One-piece encapsulated coil with minimal amperage draw.

2 3
 Oil immersed armature solenoid.
4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.
COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19 (two per valve)

Voltage available: 12, 24 VDC SPECIFICATIONS


110, 220 VAC*
Basic Model Code S574
* AC coils must be used with a rectifying connector.
A (2) B (4)

Symbol
B A
PRESSURE DROP v’s FLOW P (3) T (1)

Viscosity = 32 cSt (150 SSU) Max. Working Pressure 210 bar (3000 psi)
Flow Rating 34 litres/min (8.7 US GPM)
SPOOL SHIFTED
FLOW (US GPM) Nominal flow
20 litres/min (5 US GPM)
15
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 (at Delta P = 5 bar (70 psi))
210

11 12 175
Internal Leakage Less than 120 ml/min past each land
PRESSURE (BAR)

PRESSURE (PSI)

3-2 & 3-4


2-1 & 4-1
210 bar differential at 32 centistokes
9 130
Temperature Range -20 to +120°C (-4 to +248°F)
6 90
Nominal Viscosity Range 15 to 250 centistokes
3 45 Recommended Filtration BS5540/4 18/13 (25 micron or better)
0 0 Compatible with most general
0 5 10 15 20 25 30 35 40 Fluid
FLOW (LITRES/MIN) purpose hydraulic fluids

Seal Material Standard nitrile with PTFE back up rings


SPOOL CENTRED Seal Kit Number SK1034 (Nitrile) SK1034V (Viton)
FLOW (US GPM) Mounting Position Unrestricted
1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4
15 210 Cartridge Weight 0.25 kg (0.5 lbs)
12 175 Coil Weight 0.3 kg (0.6 lbs) - two per valve
PRESSURE (BAR)

PRESSURE (PSI)

3-2 & 3-4


2-1 & 4-1 Cavity Number A12744 (See Section 17)
9 130

Torque into Cavity 30 Nm (22 lbs ft)


6 90
Electrical Data See coil data sheet
3 45
Line Body Material Aluminium Alloy
0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-4011.A
PERFORMANCE
FLOW (US GPM)

1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4


WORKING PRESSURE (BAR) 250 3625

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 5 10 15 20 25 30 35 40
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S574 BASIC CODE: S574
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
21.00 35.50 63.50
50.00
125.00

50.00

18.50
12.00

27.00 A/F
34.50

4
11
50.50

7/8"-14-UNF-2A 4
62.50

3
73.20

3
82.60

2
2
1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S574 N H 24 3W
Basic Code Port Sizes
S574 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-4012.B
S277 Directional Control Valve - 4-Way, 3-Position Spool

Up to 11.5 litres/min (3.1 US GPM)  Up to 210 bar (3000 PSI)

S277 FEATURES
 High flow capacity with reduced space requirements.
COIL A COIL B  No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S2 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C13-*-*/22 (two per valve) SPECIFICATIONS

Voltage available: 12, 24 VDC Basic Model Code S277


110, 220 VAC* A (2) B (4)

* AC coils must be used with a rectifying connector. Symbol


B A
P (3) T (1)

Max. Working Pressure 210 bar (3000 psi)


Flow Rating 11.5 litres/min (3.1 US GPM)

Nominal flow
8 litres/min (2 US GPM)
PRESSURE DROP v’s FLOW (at Delta P = 5 bar (70 psi))

Viscosity = 32 cSt (150 SSU) Less than 100 ml/min past each land
11 Internal Leakage
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


Nominal Viscosity Range 15 to 250 centistokes
FLOW (US GPM)
0.5 1 1.5 2 2.5 3 Recommended Filtration BS5540/4 18/13 (25 micron or better)
12 145
Compatible with most general
Fluid
purpose hydraulic fluids
9 130
PRESSURE (BAR)

PRESSURE (PSI)

Seal Material Standard nitrile with PTFE back up rings


6 90 Seal Kit Number SK974 (Nitrile) SK974V (Viton)
All directions Mounting Position Unrestricted
3 45
Cartridge Weight 0.16 kg (0.35 lbs)

0 0 Coil Weight 0.2 kg (0.4 lbs) - two per valve


0 2 4 6 8 10 12
Cavity Number A6951 (See Section 17)
FLOW (LITRES/MIN)
Torque into Cavity 20 Nm (15 lbs ft)
Electrical Data See coil data sheet
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-4111.A
PERFORMANCE
FLOW (US GPM)

0.5 1 1.5 2 2.5 3 3.5 4


250 3625
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


200 2900

150 2175

100 1450

50 725

0 0
0 2 4 6 8 10 12 14 16
FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: S277 BASIC CODE: S277
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B13383
3/8” B7498 3/8” B19362
48.00
23.50 36.00 57.20
38.50
102.00

38.50

11.00

14.10

24.00 A/F
11.50

28.50

11
42.70

3/4"-16-UNF-2A 4
54.00

4
50.80

3
76.20

3
2
2
1
1 2 HOLES
ø12.60
ø7.1 THRO'
ø14.20
ø15.80 28.60 12.70
4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE

S277 N H 24 3W
Basic Code Port Sizes
S277 2W = 1/4” BSP
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-4112.B
S577R Directional Control Valve - 4-Way, 3-Position Spool

23 litres/min (7 US GPM)  Up to 210 bar (3000 PSI)

S577R FEATURES
 High flow capacity with reduced space requirements.
COIL A COIL B  No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
1
 Oil immersed armature solenoid.
2 3 4
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

COIL INFORMATION
(See Page 11-1021)

Part Number: C16-*-*/19 (two per valve)


SPECIFICATIONS
Voltage available: 12, 24 VDC
110, 220 VAC* Basic Model Code S577R
(A) 2 (B) 4
* AC coils must be used with a rectifying connector.
Symbol B A
(P) 3 (T)1

Max. Working Pressure 210 bar (3000 psi)


PRESSURE DROP v’s FLOW
Flow Rating 23 litres/min (7 US GPM)
Viscosity = 32 cSt (150 SSU)
Nominal flow
20 litres/min (5 US GPM)
SPOOL SHIFTED (at Delta P = 5 bar (70 psi))

FLOW (US GPM) Less than 100 ml/min


11 16
1.3 2.6 3.9 5.2 6.5 7.8
240
Internal Leakage
210 bar differential at 32 centistokes

Temperature Range -20 to +120°C (-4 to +248°F)


12
PRESSURE (BAR)

180
PRESSURE (PSI)

3-2 or 3-4 Nominal Viscosity Range 15 to 250 centistokes


8 120 Recommended Filtration BS5540/4 18/13 (25 micron or better)

4 60 Compatible with most general


Fluid
2-1 or 4-1
purpose hydraulic fluids
0 0
0 5 10 15 20 25 30 Seal Material Standard nitrile with PTFE back up rings
FLOW (LITRES/MIN)
Seal Kit Number SK1034 (Nitrile) SK1034V (Viton)
SPOOL CENTRED Mounting Position Unrestricted
FLOW (US GPM) Cartridge Weight 0.25 kg (0.5 lbs)
1.3 2.6 3.9 5.2 6.5 7.8
16 240 Coil Weight 0.3 kg (0.6 lbs) - two per valve
Cavity Number A12744 (See page 11-441)
PRESSURE (BAR)

PRESSURE (PSI)

12 180
Torque into Cavity 30 Nm (22 lbs ft)
8 120
Electrical Data See coil data sheet
4 60 Line Body Material Aluminium Alloy
3-1
0 0
0 5 10 15 20 25 30
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11-4211.A
PERFORMANCE
FLOW (US GPM)
1.3 2.6 3.9 5.2 6.5 7.8
280 4000
WORKING PRESSURE (BAR)

WORKING PRESSURE (PSI)


210 3000

140 2000

70 1000

0 0
0 5 10 15 20 25 30

FLOW (LITRES/MIN)

CARTRIDGE ONLY COMPLETE VALVE 3/8” 1/2” PORTS


BASIC CODE: S577R BASIC CODE: S577R
Body ONLY part numbers
BSP, aluminium SAE, aluminium
3/8” B19240
1/2” B19228 1/2” B19229
49.00
21.00 35.50 63.50
50.00
125.00

50.00

18.50
12.00

11
27.00 A/F
34.50

4
50.50

7/8"-14-UNF-2A 4
62.50

3
73.20

3
82.60

2
2
1
ø15.80 1
2 HOLES
ø17.40 ø7.1 THRO'
31.80 16.00
ø19.00 6.35 50.80 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


S577R N H 24 3W
Basic Code Port Sizes
S577R 3W = 3/8” BSP
4W = 1/2” BSP 8T = 1/2” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC 110 = 110 VAC
24 = 24 VDC 220 = 220 VAC
Manual Override (consult factory for availability)
4 = Push/Pull Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
Other terminations available on request
We reserve the right to change specifications without notice

11-4212.B
PDR2 Pressure Relief Valve

1.5 litres/min (0.3 US GPM)  350 bar (5000 PSI)


PROPORTIONAL CONTROLS

PDR2 FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS
Basic Model Code PDR2
1

Symbol

2
Max. Inlet Pressure 350 bar (5000 psi)

2 Pressure Ranges up to 10 = 5 - 120 bar (72 - 1740 psi)


75% of Max Current 20 = 10 - 240 bar (145 - 3480 psi)
Max Press Port 2 100 bar (1450 psi)
1 Max. Flow 1.5 litres/min (0.3 US GPM)
DESCRIPTION Typ. Hydraulic Hysterisis <12.5% without PWM

This valve can be infintely adjusted within a prescribed 10 = 2 - 193 ms


Response times
range by a varying electrical control signal. Pressure 20 = 3 - 395 ms
output is directly proportional to changes in DC current Dead Band 10% approx
input. Internal Leakage < 5 ml/min
Temp’ Range (oil) -20 to +120°C (-4 to +248°F)
COIL INFORMATION Nominal Viscosity Range 15 to 250 centistokes
11 (See Page 11-1021) Recommended Filtration
BS5540/4 18/13 (25 micron or
better)
Part Number: C16-*-*/19 Compatible with most general
Fluid
purpose hydraulic fluids
Voltage available: 12, 24 VDC
Standard nitrile with PTFE back up
Seal Material
rings
PRESSURE DROP
Seal Kit Number SK1119 (Nitrile) SK1119V (Viton)
FLOW US GPM
0.1 0.2 0.3 0.4 For best results mount below
14 Mounting Position reservoir oil level. If this is not
200
feasible mount horizontaly.
12
Cartridge Weight 0.25 kg (0.55 lbs)
10 150 Coil Weight 0.3 kg (0.6 lbs)
PRESSURE (BAR)

PRESSURE (PSI)

8 Cavity Number A879 (See Section 17)


100
Torque into Cavity 40 Nm (29.5 lbs ft)
6
10 - 240 bar Electrical Data See coil data sheet
4
50 Standard Aluminium (up to 210 bar)
5 - 120 bar Line Body Material
2 Add suffix “377” for steel option

0 0
0 0.25 0.50 0.75 1.00 1.25 1.50 *For applications above 210 bar please consult our
FLOW LITRES/MIN technical department or use the steel body option.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11/2-151.A
FLOW US GPM
PERFORMANCE 0.1 0.2 0.3 0.4

PROPORTIONAL CONTROLS
350 5000 350 5000
5 - 120 bar
10 - 240 bar
300 300
4000 75% 4000
250 250

PRESSURE (BAR)

PRESSURE (PSI)
10 - 240 bar
PRESSURE (BAR)

PRESSURE (PSI)
200 3000 200 3000

50%
150 150
2000 75% 2000
100 100
50%
5 - 120 bar 1000 25% 1000
50 50
25%
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 0.25 0.50 0.75 1.00 1.25 1.50
% OF RATED CURRENT FLOW LITRES/MIN

Relief Pressure vs Input Current (24 Vdc)

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: PDR2 BASIC CODE: PDR2
Body ONLY part numbers

49.00 35.50 BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/4” A1485 1/4” A14842 1/4” A14128
21.00 3/8” A1043 3/8” A15676 3/8” A14175 3/8” A14843
101.00

50.00

24.0 A/F
12.7
19.4
0

11
2
29.00

28.8

3/4"-16 UNF
T (2)
44.8
50.8

ø12.60 P (1)
1

16.0 15.9
31.0 31.8
44.0 2 HOLES
50.0 ø6.8 THRO'

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


PDR21A N 20 6 H 24 3W
Basic Code Port Sizes
PDR21A = Normally Open 2W = 1/4” BSP 4T = 1/4” SAE
3W = 3/8” BSP 6T = 3/8” SAE
Seals
N = Nitrile Voltage
V = Viton 12 = 12 VDC
24 = 24 VDC
Pressure Range
10 = 5 to 120 bar Coil Termination
20 = 10 to 240 bar H = DIN43650
F = Flying Leads
Manual Override DM = Deutsch Moulded
6 = Screw Other terminations available on
request
We reserve the right to change specifications without notice

11/2-152.A
PPD2 2A/H Pressure Reducing Valve
3-Way, 2-Position
20 litres/min (5.4 US GPM)  210 bar (3000 PSI)
PROPORTIONAL CONTROLS

PPD2 2A FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS

Basic Model Code PPD2 2

1 (Reg)

Symbol
3 (TANK)

3 (Tank) 2 (pres)

2 (PRES) Max. Inlet Pressure 210 bar (3000 psi)


19 watt coil 24 Bar
Max. Regulated Pres 29 watt coil 28 Bar
1 REG)
18.6 litres/min (5 US GPM) 19 W coil
Max Regulated Flow
20 litres/min (5.4 US GPM) 29 W coil

COIL INFORMATION Hysterisis preferred 16% Maximum without PWM


PWM
(See Page 11-431)
Frequency 200 Hz
11 Part Number: C16-*-*/19 (PPD2 2A)
C16-*-*/29 (PPD2 2AH)
Dead Band 19% of rated current
Up to 50 ml/min
Internal Leakage
210 bar differential at 32 centistokes
Voltage available: 12, 24 VDC
Temp’ Range (oil) -20 to +120°C (-4 to +248°F)
PRESSURE DROP v’s FLOW Nominal Viscosity Range 15 to 250 centistokes

Viscosity = 32 cSt (150 SSU) Recommended Filtration BS5540/4 18/13 (25 micron or better)

Compatible with most general


PPD2 2A Fluid purpose hydraulic fluids
FLOW US (GPM)
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Seal Material Standard nitrile with PTFE back up rings
50
Seal Kit Number SK1119 (Nitrile) SK1119V (Viton)
40 600
Mounting Position Unrestricted
PRESSURE (BAR)

PRESSURE (PSI)

30 450 Cartridge Weight 0.25 kg (0.55 lbs)


2-1
20 300 Coil Weight 0.3 kg (0.6 lbs)
Cavity Number A3531 (See Section 17)
10 150
1-3 Torque into Cavity 30 Nm (22 lbs ft)
0 0
0 2 4 6 8 10 12 14 16 18 20 Electrical Data See coil data sheet
FLOW (LITRES/MIN)
Line Body Material Aluminium Alloy

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11/5-105.A
PERFORMANCE 30

PROPORTIONAL CONTROLS
400
25
PRESSURE (BAR)

PRESSURE (PSI)
20 300
PPD2 2AH
15
200
PPD2 2A
10

100
5

0 0
0 10 20 30 40 50 60 70 80 90 100
% OF RATED CURRENT

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: PPD2 2A/H BASIC CODE: PPD2 2A/H
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” B7724
3/8” B6684 3/8” B6516
49.00 57.20
35.50
21.00 5.00 A/F
7.00

MAN OVERRIDE
10.00 A/F
MAN OVERRIDE
LOCKNUT
92.00

50.00

11.10

14.70
16.90

11
24.00 A/F
28.30

3/4"-16-UNF-2A
3 (Tank) 3
39.80

2
38.10

2 (Pressure)

1
1 (Regulated)
Ø14.20
2 HOLES
Ø15.80 Ø7.1 THRO'
28.60 12.70

4.80 47.60 25.40

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


PPD2 2A N 6 H 24 3W
Basic Code Port Sizes
PPD2 2A = (standard valve) 2W = 1/4” BSP
PPD2 2AH = (heavy duty valve) 3W = 3/8” BSP 6T = 3/8” SAE
Seals Voltage
N = Nitrile 12 = 12 VDC
V = Viton 24 = 24 VDC
Manual Override Coil Termination
6 = Screw H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on
request
11/5-106.E
PFR2 4A Flow Control Valve
2 Port Restrictive Pressure Compensated
18 litres/min (4.7 US GPM)  210 bar (3000 PSI)
PROPORTIONAL CONTROLS

PFR2 4A FEATURES
 High flow capacity with reduced space requirements.
 No dynamic seals.
 Standard valve bodies and common cavities.
 One-piece encapsulated coil with minimal amperage draw.
 Oil immersed armature solenoid.
 Various coil terminals and voltages.
 Coil interchangeability with all Series S5 valves.
 Manual override, seal variations and other options available.
 Sealed coil arrangement to protect stem from corrosion.

SPECIFICATIONS
Basic Model Code PFR2 4A
2

Symbol

1
(OUT)

2 (IN) Max. Inlet Pressure 210 bar (3000 psi)

*Max Regulated Flow at 28 litres/min @ 100%, 23 litres/min @


rated current @ 30 bar 85%, 18 litres @ 75%
1 (OUT) Hysterisis 8% Maximum without PWM
4% Maximum with PWM
Frequency 200 Hz to 400 Hz - 200 recommended

COIL INFORMATION Dead Band 25-35% of rated current

(See Page 11-1021) Response Time 300 ms

11 Part Number: C16-*-*/19 Internal Leakage


Up to 200 ml/min
210 bar differential at 32 centistokes
Voltage available: 12, 24 VDC Temp’ Range (oil) -20 to +120°C (-4 to +248°F)

Nominal Viscosity Range 15 to 250 centistokes

PRESSURE DROP v’s FLOW Recommended Filtration BS5540/4 16/13 (25 micron or better)
Compatible with most general
Viscosity = 32 cSt (150 SSU) Fluid purpose hydraulic fluids

PFR2 4A @ 100% Seal Material Standard nitrile with PTFE back up rings
Seal Kit Number SK1138 (Nitrile) SK1138V (Viton)
FLOW US (GPM)
2.5 5 7.5 10 Mounting Position Unrestricted
25
350 Cartridge Weight 0.2 kg (0.44 lbs)
300
20 Coil Weight 0.3 kg (0.6 lbs)
PRESSURE (BAR)

PRESSURE (PSI)

250
15 Cavity Number A6701 (See Section 17)
200
150
Torque into Cavity 30 Nm (22 lbs ft)
10
100 Electrical Data See coil data sheet
5
50 Line Body Material Aluminium Alloy
0
5 10 15 20 25 30 40
* Based on a saturated inlet with an increasing signal.
FLOW (LITRES/MIN)

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
11/9-121.B
PERFORMANCE

PROPORTIONAL CONTROLS
PRESSURE (PSI)
0 500 1000 1500 2000 2500 3000
35 35
9 9
100% of rated amps
30 8 30 8

7 7
25 25
FLOW (LITRES/MIN)

FLOW (LITRES/MIN)
6

FLOW US (GPM)
6

FLOW US (GPM)
75% of rated amps
20 5 20 5

15 4 15 4

3 3
10 10
2 50% of rated amps 2
5 5
1 1
0 0
10 20 30 40 50 60 70 80 90 100 20 40 60 80 100 120 140 160 180 200 220
% Rated Amps PRESSURE DIFFERENTIAL BAR

CARTRIDGE ONLY COMPLETE VALVE 1/4” 3/8” PORTS


BASIC CODE: PFR2 4A BASIC CODE: PFR2 4A
Body ONLY part numbers
BSP, aluminium SAE, aluminium
1/4” A12592
3/8” A7450 3/8” A19355

49.00 35.50 50.00


5.00 A/F
7.00

21.00

10.00 A/F
92.00

50.00

11
16.90

2 HOLES
24.00 A/F Ø6.8 THRO'
2
12.80

50.80

3/4"-16-UNF-2A
27.8

2
22.00

1
1
Ø15.80
6.00

15.90
16.00
19.00 6.00 31.80

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


PFR2 4A N 6 H 24 3W
Basic Code Port Sizes
PFR2 4A 2W = 1/4” BSP
Seals 3W = 3/8” BSP 6T = 3/8” SAE
N = Nitrile Voltage
V = Viton 12 = 12 VDC
Manual Override 24 = 24 VDC
6 = Screw Coil Termination
H = DIN43650
F = Flying Leads
DM = Deutsch Moulded
We reserve the right to change specifications without notice Other terminations available on
request
11/9-122.D