Вы находитесь на странице: 1из 1

TS EN81-20 LIFT DOOR PHOTOCELL

USER MANUAL
POWER BOX Caution! Must be
Connected to the Ground
Mounting;
Mount the lift door photocell to the cabin or cabin door with the RX and TX laths aligned.
100
K20 yada Photocell Place the photocell power box on the cabinet and connect to the mains and ground.

Network Power Connect the RX and TX cables to the power box. Make sure that neither cable is attached
(240VAC) 50Hz to the moving mechanism of the door. Keep cables away from cables with high voltage.
6AWG Cable 2500 mm
Connect the relay outputs (RELAY OUT). Connection and change according to control
system.

LATH Working Mode;


The GREEN power LED will light when the mains voltage is supplied to the photocell
power box.

If there is an obstacle between the receiver and the transmitter (RX-TX), the RED relay
LED will light. In this case the relay output will change position.

If the obstacle between the receiver and the transmitter (RX-TX) is not reached after a
47 mm certain period of time, the buzzer will be emitted with the built-in buzzer.
4x7,5 mm
Warning: If there is no obstacle between RX-TX and RED (relay led) led is on; check the
High connection cables ground line and the alignment of the photocell strips.
128 mm 38,5 mm
Maintenance;
2000 or1900 mm R 4 mm
The front plexi surface must be clean. It can be cleaned with a soft damp cloth.
Photocell Lath
LATH
2000x11x27 mm
The front surface should not be scratched in order to ensure that the infrared
communication is not disturbed.
193 mm
573 mm It should move easily in the door mechanism of the lath cable.
953 mm
1533 mm
1733 mm

TS EN81-20