Вы находитесь на странице: 1из 44

BellTel Project 2G/4G Nationwide BellTel Project 2G/4G Nationwide

Site Labeling Guidelines


BellTel Project 2G/4G Nationwide
Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Site Labeling Guidelines

BellTel Project 2G/4G Nationwide


Author: Manager Responsible:
Wu Shuzhong Quality Manager
Doc No: Version: Controlled Copy No:
BTL P15-PM-QM-STD-LB-001 V1.5
Related Documents: Document Type:
Quality Standard
Document Title: File Reference:
Site Labeling Guidelines
Authorised by:

Version No. Date No. of Initials Details of Revision Changes


pages
V1.0 2015-11-16 28 Y First Draft

V1.1 2015-11-20 31 Revised Version

V1.2 2015-11-22 35 Revised Version

V1.3 2015-11-30 40 Revised Version

V1.4 2015-12-3 42 Revised Version

V1.5 2016-01-10 45 Revised Version

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 3 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

TABLE OF CONTENTS

1 Purpose .............................................................................................................. 5

2 Labeling Material and Text Requirement ......................................................... 5


2.1 Outdoor Cable Labeling ....................................................................................... 5
2.2 Indoor Cable Labeling .......................................................................................... 5
2.3 Indoor Component Labeling ................................................................................. 6
2.4 Outdoor component Labeling ............................................................................... 7
2.5 Labeling for Site ID & Configuration ..................................................................... 8

3 TTA/RTA ........................................................................................................... 10
3.1 Component Labeling .......................................................................................... 10
3.2 Cable Labeling ................................................................................................... 14

4 BBU .................................................................................................................. 23
4.1 Component Labeling .......................................................................................... 23
4.2 Cable Labeling ................................................................................................... 25

5 MW.................................................................................................................... 29
5.1 Component Labeling .......................................................................................... 29
5.2 Cable Labeling ................................................................................................... 31

6 IPRAN ............................................................................................................... 34
6.1 Cable Labeling ................................................................................................... 34

7 Power and Grounding Cable .......................................................................... 39


7.1 Component Labeling .......................................................................................... 39
7.2 Cable Labeling ................................................................................................... 42

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 4 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

1 Purpose
The purpose of this document is to describe the labeling guidelines and standard of cable and

component for RAN and Transmission.

2 Labeling Material and Text Requirement

2.1 Outdoor Cable Labeling

The outdoor cable label will use the material as below (include RAN, MW and Power). Text will be

double printed to make reading easier.


Figure 2-1

2.2 Indoor Cable Labeling

The indoor label will use the material as below, the colour is white and had confirmed by BellTel.

The text is back, text should be laser printed.

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 5 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 2-2

2.3 Indoor Component Labeling

The indoor component label will use the material as below, the colour is white and the text is back,

text should be laser printed.

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 6 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 2-3

2.4 Outdoor component Labeling

For Site ID & Configuration labeling in the cabinet door, Sector labeling in RTA/TTA and MW

Antenna labeling, will use the material as below, size 3.125 inches x 2.375 inches, waterproof, the

colour is white and the text is back, text height should be not less than15mm.

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 7 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 2-4

2.5 Labeling for Site ID & Configuration

The labeling for site ID and configuration is showing the configuration and component quantity of

the site.

 Label description and label name


Table 2-1

Name Format: Model_BBU_IPRANspace_MW IDU_Rectifier_Battery

Label Name Remar


3kW_4Hr_ODC_0_B0_IP0_M0_PS3_BB2 k
3kW_4Hr_ODC_0_B1_IP1_M0_PS3_BB2
3kW_4Hr_ODC_0_B1_IP1_M1_PS3_BB2
3kW_4Hr_ODC_0_B1_IP3_M0_PS3_BB2
5kW_4Hr_Ext_0_B2_IP1_M0_PS4_BB4
5kW_4Hr_Ext_0_B2_IP3_M0_PS4_BB4 Indoor
5kW_4Hr_Ext_0_B2_IP3_M1_PS4_BB4
3kW_4Hr_ODC_B1_IP1U_M0_PS3_BB2
3kW_4Hr_ODC_B1_IP1U_M1_PS3_BB2
3kW_4Hr_ODC_B1_IP3U_M0_PS3_BB2
3kW_8Hr_Ext_B0_IP1U_M2_PS4_BB4

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 8 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

3kW_8Hr_Ext_B1_IP1U_M0_PS4_BB4
3kW_8Hr_Ext_B1_IP1U_M1_PS4_BB4
3kW_8Hr_Ext_B1_IP3U_M0_PS4_BB4
4kW_8Hr_Ext_B1_IP1U_M1_PS4_BB5
4kW_8Hr_Ext_B1_IP1U_M2_PS4_BB5
4kW_8Hr_Ext_B1_IP3U_M0_PS4_BB5
4kW_8Hr_Ext_B1_IP3U_M1_PS4_BB5
2kW_8Hr_Ext_B0_IP1U_M0_PS3_BB3
2kW_8Hr_Ext_B0_IP1U_M1_PS3_BB3
2kW_8Hr_Ext_B0_IP1U_M2_PS3_BB3
3kW_4Hr_ODC_B1_IP1U_M0_PS3_BB2
3kW_4Hr_ODC_B1_IP1U_M1_PS3_BB2
3kW_4Hr_ODC_B1_IP3U_M0_PS3_BB2
3kW_4Hr_ODC_B1_IP3U_M1_PS3_BB2
3kW_8Hr_Ext_B1_IP1U_M0_PS4_BB4
3kW_8Hr_Ext_B1_IP1U_M1_PS4_BB4
3kW_8Hr_Ext_B1_IP3U_M0_PS4_BB4
4kW_3Hr_ODC_B1_IP1U_M1_PS4_BB2
4kW_3Hr_ODC_B1_IP3U_M0_PS4_BB2
4kW_3Hr_ODC_B1_IP3U_M1_PS4_BB2
4kW_3Hr_ODC_B1_IP3U_M2_PS4_BB2
4kW_8Hr_Ext_B1_IP1U_M1_PS4_BB5
4kW_8Hr_Ext_B1_IP3U_M0_PS4_BB5
4kW_8Hr_Ext_B1_IP3U_M1_PS4_BB5

 Labeling Standard
Figure 2-5

Site ID and
configuration labeling

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 9 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

3 TTA/RTA

3.1 Component Labeling

The letter/numbers should have a minimum height of 15mm.The component labels of TTA/RTA are

provided by CommScope.

1. Antenna

 Label description and label name

 Metro TTA/RTA
Table 3-1
Label Description Label Name Remark
Sector A Antenna RPX/RVV A01 Outdoor
Sector A Antenna RVV/RV4 A02 Outdoor
Sector B Antenna RPX/RVV A03 Outdoor
Sector B Antenna RVV/RV4 A04 Outdoor
Sector C Antenna RPX/RVV A05 Outdoor
Sector C Antenna RVV/RV4 A06 Outdoor

 Split TTA/RTA
Table 3-2
Label Description Label Name Remark
Antenna RPX/RVV A01 Outdoor
Antenna RVV/RV4 A02 Outdoor

 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 10 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-1

Antenna labeling

2. Coupler

 Label description and label name

 Metro TTA/RTA
Table 3-3
Label Description Label Name Remark
Coupler to Sector A Antenna A01 COUPLER C01 Outdoor
Coupler to Sector A Antenna A01 COUPLER C02 Outdoor
Coupler to Sector A Antenna A02 COUPLER C03 Outdoor
Coupler to Sector A Antenna A02 COUPLER C04 Outdoor
Coupler to Sector B Antenna A03 COUPLER C05 Outdoor
Coupler to Sector B Antenna A03 COUPLER C06 Outdoor
Coupler to Sector B Antenna A04 COUPLER C07 Outdoor
Coupler to Sector B Antenna A04 COUPLER C08 Outdoor
Coupler to Sector C Antenna A05 COUPLER C09 Outdoor
Coupler to Sector C Antenna A05 COUPLER C10 Outdoor
Coupler to Sector C Antenna A06 COUPLER C11 Outdoor
Coupler to Sector C Antenna A06 COUPLER C12 Outdoor

 Split TTA/RTA
Table 3-4
Label Description Label Name Remark
Coupler to Antenna A01 COUPLER C01 Outdoor
Coupler to Antenna A01 COUPLER C02 Outdoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 11 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Coupler to Antenna A02 COUPLER C03 Outdoor


Coupler to Antenna A02 COUPLER C04 Outdoor

 Labeling Standard
Figure 3-2

Coupler labeling

3. Filter

 Label description and label name

 Metro TTA/RTA
Table 3-5
Label Description Label Name Remark
Sector A Filter to COUPLER C01&C03 FILTER F01 Outdoor
Sector A Filter to COUPLER C05&C07 FILTER F02 Outdoor
Sector B Filter to COUPLER C09&C11 FILTER F03 Outdoor
Sector B Filter to COUPLER C02&C04 FILTER F04 Outdoor
Sector C Filter to COUPLER C06&C08 FILTER F05 Outdoor
Sector C Filter to COUPLER C10&C12 FILTER F06 Outdoor

 Split TTA/RTA (2X700 RRU)


Table 3-6
Label Description Label Name Remark
Filter to COUPLER C01&C03 FILTER F01 Outdoor
Filter to COUPLER C02&C04 FILTER F02 Outdoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 12 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

 Split TTA/RTA (4X700 RRU/TDD-2 X700 RRU)


Table 3-7
Label Description Label Name Remark
Filter to COUPLER C01&C03 FILTER F01 Outdoor
Filter to COUPLER C02&C04 FILTER F02 Outdoor

 Labeling Standard
Figure 3-3

Filter labeling

4. Sector

 Label description and label name and labeling Standard (For Split only)

The label should be put in the Junction Box of Split RTA/TTA

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 13 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-4

3.2 Cable Labeling

The labeling for RF feeder cable, AISG cable and Fiber Trunk were provided by CommScope. The

material and labeling format CommScope had confirmed with BellTel.

1. RF Feeder Cable

 Label Description and label name

 From RRU to Antenna

 Metro TTA/RTA

Table 3-8
Label Description Label Name Remark
RF Cable for 1800MHz RRU01 to Antenna A02&A04&A06 RF-18R01-x Outdoor
RF Cable for 1800MHz RRU02 to Antenna A02&A04&A06 RF-18R02-x Outdoor
 Split TTA/RTA

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 14 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Table 3-9
Label Description Label Name Remark
RF Cable for 1800MHz RRU01 to Antenna A02 RF-18R01-x Outdoor

 From RRU to Coupler

 Metro TTA/RTA

Table 3-10
Label Description Label Name Remark
RF Cable for 700MHz RRU01 to COUPLER RF-7R01-x Outdoor
RF Cable for 700MHz RRU02 to COUPLER
C01&C02&C03&C04 RF-7R02-x Outdoor
RF Cable for 700MHz RRU03 to COUPLER
C05&C06&C07&C08 RF-7R03-x Outdoor
C09&C10&C11&C12  Split TTA/RTA

Table 3-11
Label Description Label Name Remark
RF Cable for 700MHz RRU01 to COUPLER C01&C02 RF-7R01-x Outdoor
RF Cable for 700MHz RRU02 to COUPLER C03&C04 RF-7R02-x Outdoor

 From RRU to Filter

 Metro TTA/RTA

Table 3-12
Label Description Label Name Remark
RF Cable for 900MHz RRU01 to FILTER F01&F03&F05 RF-9R01-x Outdoor
RF Cable for 900MHz RRU02 to FILTER F02&F04&F06 RF-9R02-x Outdoor
 Split TTA/RTA

Table 3-13
Label Description Label Name Remark
RF Cable for 900MHz RRU01 to FILTER F01&F02 RF-9R01-x Outdoor

 From Filter to Coupler


 Metro TTA/RTA

Table 3-14
Label Description Label Name Remark
RF Cable for FILTER F01 to COUPLER C01&C02 RF-F01-x Outdoor
RF Cable for FILTER F02 to COUPLER C03&C04 RF-F02-x Outdoor
RF Cable for FILTER F03 to COUPLER C05&C06 RF-F03-x Outdoor
RF Cable for FILTER F04 to COUPLER C07&C08 RF-F04-x Outdoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 15 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

RF Cable for FILTER F05 to COUPLER C09&C10 RF-F05-x Outdoor


RF Cable for FILTER F06 to COUPLER C11&C12 RF-F06-x Outdoor
 Split TTA/RTA

Table 3-15
Label Description Label Name Remark
RF Cable for FILTER F01 to COUPLER C01&C02 RF-F01-x Outdoor
RF Cable for FILTER F02 to COUPLER C03&C04 RF-F02-x Outdoor

 From Coupler to Antenna

 Metro TTA/RTA

Table 3-16
Label Description Label Name Remark
RF Cable for COUPLER C01 to Antenna A01 RF-C01-x Outdoor
RF Cable for COUPLER C02 to Antenna A02 RF-C02-x Outdoor
RF Cable for COUPLER C03 to Antenna A01 RF-C03-x Outdoor
RF Cable for COUPLER C04 to Antenna A02 RF-C04-x Outdoor
RF Cable for COUPLER C05 to Antenna A03 RF-C05-x Outdoor
RF Cable for COUPLER C06 to Antenna A04 RF-C06-x Outdoor
RF Cable for COUPLER C07 to Antenna A03 RF-C07-x Outdoor
RF Cable for COUPLER C08 to Antenna A04 RF-C08-x Outdoor
RF Cable for COUPLER C09 to Antenna A05 RF-C09-x Outdoor
RF Cable for COUPLER C10 to Antenna A06 RF-C10-x Outdoor
RF Cable for COUPLER C11 to Antenna A05 RF-C11-x Outdoor
RF Cable for COUPLER C12 to Antenna A06 RF-C12-x Outdoor
 Split TTA/RTA

Table 3-17
Label Description Label Name Remark
RF Cable for COUPLER C01 to Antenna A01 RF-C01-x Outdoor
RF Cable for COUPLER C02 to Antenna A02 RF-C02-x Outdoor
RF Cable for COUPLER C03 to Antenna A01 RF-C03-x Outdoor
RF Cable for COUPLER C04 to Antenna A02 RF-C04-x Outdoor

 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 16 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-5

Waterproof Labeling

Connector 3cm

Figure 3-6

Jumper cable
labeling
(RRU)

Jumper cable RRU side


Figure 3-7

Jumper cable
labeling

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 17 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Jumper cable combiner/filter side


Figure 3-8

Jumper cable
labeling

Jumper cable antenna side

2. AISG Cable

 Label Description and label name

 From RRU to Antenna

 Metro TTA/RTA

Table 3-18
Label Description Label Name Remark
AISG Cable form 700MHz RRU01 to Antenna A01 AISG-7R01-1 Outdoor
AISG Cable form 700MHz RRU02 to Antenna A03 AISG-7R02-1 Outdoor
AISG Cable form 700MHz RRU03 to Antenna A05 AISG-7R03-1 Outdoor
 Split TTA/RTA

Table 3-19
Label Description Label Name Remark
AISG Cable form 700MHz RRU01 to Antenna A01 AISG-7R01-1 Outdoor

 Between Antennas

 Metro TTA/RTA

Table 3-20
Label Description Label Name Remark

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 18 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

AISG Cable form Antenna A01 to Antenna A02 AISG-A01-3 Outdoor


AISG Cable form Antenna A03 to Antenna A04 AISG-A03-3 Outdoor
AISG Cable form Antenna A05 to Antenna A06 AISG-A05-3 Outdoor
 Split TTA/RTA

Table 3-21
Label Description Label Name Remark
AISG Cable form Antenna A01 to Antenna A02 AISG-A01-3 Outdoor

 Labeling Standard
Figure 3-9

Labelling

Connector 3cm

Figure 3-10

AISG cable labeling

AISG cable

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 19 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

3. Fiber Trunk Cable

 Label description and label name

 From Fiber Box to RRU

 Metro TTA/RTA

Table 3-22
Label Description Label Name Remark
OF Cable From Fiber Box to 700MHz RRU01 OF-7R01-7 Outdoor
OF Cable From Fiber Box to 700MHz RRU02 OF-7R02-7 Outdoor
OF Cable From Fiber Box to 700MHz RRU03 OF-7R03-7 Outdoor
OF Cable From Fiber Box to 900MHz RRU01 OF-9R01-1 Outdoor
OF Cable From Fiber Box to 900MHz RRU02 OF-9R02-1 Outdoor
OF Cable From Fiber Box to 1800MHz RRU01 OF-18R01-1 Outdoor
OF Cable From Fiber Box to 1800MHz RRU02 OF-18R02-1 Outdoor
 Split TTA/RTA

Table 3-23
Label Description Label Name Remark
OF Cable From Fiber Box to 700MHz RRU01 OF-7R01-7 Outdoor
OF Cable From Fiber Box to 700MHz RRU02 OF-7R02-7 Outdoor
OF Cable From Fiber Box to 900MHz RRU01 OF-9R01-1 Outdoor
OF Cable From Fiber Box to 1800MHz RRU01 OF-18R01-1 Outdoor

 From Fiber Box to Power Cabinet

 Metro TTA/RTA

Table 3-24
Label Description Label Name Remark
OF Cable From Fiber Box to Power Cabinet OF-Cabinet Outdoor
 Split TTA/RTA

Table 3-25
Label Description Label Name Remark
Sector A OF Cable From Fiber Box to Power Cabinet OF-Cabinet-SA Outdoor
Sector B OF Cable From Fiber Box to Power Cabinet OF-Cabinet-SB Outdoor
Sector C OF Cable From Fiber Box to Power Cabinet OF-Cabinet-SC Outdoor

 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 20 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-11

DC Power
Connector
Labeling cable

Fiber
3cm Rubber tube

Figure 3-12

Fiber Trunk
cable labeling

Fiber Trunk to RRU

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 21 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-13

Fiber Trunk
Cable labeling

Fiber Trunk Cable to Cabinet

4. DC Power Trunk Cable (From Fiber Box to cabinet)

 Label description and label name


Table 3-26
Label Description Label Name Remark
DC Supply for Metro TTA and Metro RTA PS-SA/SB/SC Indoor/Outdoor
PS-SA
DC Supply for Split TTA and Split RTA PS-SB Indoor/Outdoor
PS-SC

 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 22 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 3-14

DC Power Trunk
Cable labelling

4 BBU

4.1 Component Labeling

1. BBU Module
Figure 4-1

BBU labeling
BBU01

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 23 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 4-2

2. MPO Cassette

 Split Sector
Figure 4-3

SA SB SC

 Metro
Figure 4-4

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 24 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

4.2 Cable Labeling

1. DC Power Cable

 Label description and label name


Table 4-1
Label Description Label Name Remark
DC Supply for FDD BBU PS-BBU01 Indoor
DC Supply for TDD BBU PS-BBU02 Indoor

 Labeling Standard
Figure 4-5

3cm
01
PS-FDD-BBU

BBU DC Power cable

2. Optical Fiber

 Label description and label name

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 25 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

 Split TTA/RTA - MPO Cassette


Table 4-2
Label Description Label Name Remark
OF-SA Indoor
Split TTA/RTA OF-SB Indoor
OF-SC Indoor

 Split (GSM/FDD): 6*R8863(900M/1800M)+ 6*R8882(700M)


Table 4-3
Label Description Label Name (Patch Remark
Panel side)
9R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX0/RX0 Indoor

9R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX1/RX1 Indoor

9R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX2/RX2 Indoor

18R01 Optical Fiber from Patch Panel to FDDBBU OF-BBU01-FS5-TX3/RX3 Indoor

18R02 Optical Fiber from Patch Panel to FDDBBU OF-BBU01-FS5-TX4/RX4 Indoor

18R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX5/RX5 Indoor

7R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX0/RX0 Indoor

7R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX1/RX1 Indoor

7R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX2/RX2 Indoor

7R04 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX3/RX3 Indoor

7R05 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX4/RX4 Indoor

7R06 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX5/RX5 Indoor

 Split (GSM/FDD): 6*R8863(900M/1800M)+ 3*R8862A(700M)


Table 4-4
Label Description Label Name Remark

9R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX0/RX0 Indoor

9R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX1/RX1 Indoor

9R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX2/RX2 Indoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 26 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

18R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX3/RX3 Indoor

18R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX4/RX4 Indoor

18R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX5/RX5 Indoor

7R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX0/RX0 Indoor

7R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX1/RX1 Indoor

7R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX2/RX2 Indoor

 Metro (GSM/FDD): 4*R8863(900M/1800M)+ 3*R8862A(700M)


Table 4-5
Label Description Label Name (Patch Remark
Panel side)

9R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX0/RX0 Indoor

9R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX1/RX1 Indoor

18R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX3/RX3 Indoor

18R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-FS5-TX4/RX4 Indoor

7R01 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX0/RX0 Indoor

7R02 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX1/RX1 Indoor

7R03 Optical Fiber from Patch Panel to FDD BBU OF-BBU01-BPN2-TX2/RX2 Indoor

 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 27 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 4-6

3cm

Optical Fiber

3. GPS Cable

 Label description and label name


Table 4-6
Label Description Label Name Remark

From BBU to GPS Antenna GPS Indoor

 Labeling Standard
Figure 4-7

GP
S

GPS cable

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 28 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

5 MW

5.1 Component Labeling

1. MW Antenna

 Label description and label name

 Single Antenna
Table 5-1
Label Description Label Name Remark
NR8950 All Outdoor Radio 01 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8950 All Outdoor Radio 02 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8950 All Outdoor Radio 03 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8950 All Outdoor Radio 04 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8250 Split Type Radio 01 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8250 Split Type Radio 02 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8250 Split Type Radio 03 Near End Site ID-Far End Site ID ANT1 Outdoor
NR8250 Split Type Radio 04 Near End Site ID-Far End Site ID ANT1 Outdoor

 Space Diversity
Table 5-2
Label Description Label Name Re
NR8950 All Outdoor Radio 01 Near End Site ID-Far End Site ID MAIN Outdoor
mark
NR8950 All Outdoor Radio 01 Near End Site ID-Far End Site ID DIVERSITY Outdoor
NR8950 All Outdoor Radio 02 Near End Site ID-Far End Site ID MAIN Outdoor
NR8950 All Outdoor Radio 02 Near End Site ID-Far End Site ID DIVERSITY Outdoor
NR8250 Split Type Radio 01 Near End Site ID-Far End Site ID MAIN Outdoor
NR8250 Split Type Radio 01 Near End Site ID-Far End Site ID DIVERSITY Outdoor
NR8250 Split Type Radio 02 Near End Site ID-Far End Site ID MAIN Outdoor
NR8250 Split Type Radio 02 Near End Site ID-Far End Site ID DIVERSITY Outdoor

 Labeling Standard

The letter/numbers should have a minimum height of 15mm.

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 29 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 5-1

MW Antenna Labeling
2. ODF

 Label description and label name


Table 5-3
Label Description Label Name Remark
Indicate the connection of Far
end site and Near end site in Near End Site ID-Far End Site ID Indoor
the specified port of ODF

 Labeling Standard
Figure 5-2

ODF Labeling

BellTel Supplied ODF

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 30 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

ODF Labeling

ZTE Supplied ODF

5.2 Cable Labeling

1. DC Power Cable

 Label description and label name


Table 5-4
Label Description Label Name Remark
Primary DC Supply for NR8250#1 PS-IDU1-1 Indoor
Secondary DC Supply for NR8250#1 PS-IDU1-2 Indoor
Primary DC Supply for NR8250#2 PS-IDU2-1 Indoor
Secondary DC Supply for NR8250#2 PS-IDU2-2 Indoor
DC Supply for NR8950 #1 PS-AOU1 Indoor/Outdoor
DC Supply for NR8950 #2 PS-AOU2 Indoor/Outdoor

 Labeling Standard
Figure 5-3

PS-IDUx-1

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 31 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

PS-IDUx-2

PS-IDUx-1

PS-IDUx-2

MW IDU NR8250 DC Power cable


Figure 5-4

3cm

PS–AOUx

MW NR8950 DC Power Cable

2. IF Cable

 Label description and label name

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 32 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Table 5-5
Label Description Label Name Rem
IF Cable for NR8250 ODU#1 Near End Site ID-Far End Site ID V Outdoor
ark
IF Cable for NR8250 ODU#1 Near End Site ID-Far End Site ID H Outdoor
IF Cable for NR8250 ODU#2 Near End Site ID-Far End Site ID V Outdoor
IF Cable for NR8250 ODU#2 Near End Site ID-Far End Site ID H Outdoor
IF Cable for NR8250 ODU#1 Near End Site ID-Far End Site ID MIMO_V Outdoor
IF Cable for NR8250 ODU#2 Near End Site ID-Far End Site ID MIMO_H Outdoor

 Labeling Standard
Figure 5-5

IF Labeling
in IDU side

IF Labeling
in IDU side

MW IF cable (IDU Side, Indoor)

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 33 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 5-6

Waterproof NR8250 ODU IF Cable


Labeling
3cm

MW IF cable (ODU Side, Outdoor)

3. Optical Fiber (MW-IPRAN)

Please see chapter 6.IP RAN

6 IPRAN

6.1 Cable Labeling

1. DC Power Cable

 Label description and label name


Table 6-1
Label Description Label Name Remar
Primary DC Supply for IPRAN 6120S PS-IPRAN CSR-1 k
Indoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 34 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Secondary DC Supply for IPRAN 6120S PS-IPRAN CSR-2 Indoor

Primary DC Supply for IPRAN 90002E4 PS-IPRAN ACC-1 Indoor

Secondary DC Supply for IPRAN 90002E4 PS-IPRAN ACC-2 Indoor

 Labeling Standard
Figure 6-1

IP RAN DC Power
Cable Labelling

IP RAN DC Power cable


PS-IPRAN CSR-1

PS-IPRAN CSR-2
IPRAN 6120S

PS-IPRAN ACC-1 IPRAN 90002E4 PS-IPRAN ACC-2

2. Optical Fiber

 IPRAN-BBU

 Label description and label name

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 35 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Table 6-2
Label Description Label Name (BBU side) Label Name (IPRAN side) Remark
BBU1 C16_TX/RX-IPRAN IPRAN ACC1/3/15-BBU1
IPRAN 90002E4 to FDD BBU Indoor
ACC1/3/15 CC16_TX/RX
BBU1
IPRAN CSR1/2/3-BBU1
IPRAN 6120S to FDD BBU CC16_TX/RX-IPRAN Indoor
CC16_TX/RX
CSR1/2/3
BBU2
IPRAN ACC1/3/16-BBU2
IPRAN 90002E4 to TDD BBU CCT_ETH2_TX/RX-IPRA Indoor
CCT_ETH2_TX/RX
N ACC1/3/16
BBU2
IPRAN CSR1/2/4-BBU2
IPRAN 6120S to TDD BBU CCT_ETH2_TX/RX-IPRA Indoor
CCT_ETH2_TX/RX
N CSR1/2/4

 IPRAN-MW(NR8250)

 Label description and label name


Table 6-3
Label Label Name (IPRAN Side) Label Name (IDU Side) Remar
Description IPRAN IDU1/2/GbE1(TX)-IPRAN Indoor
k
OF Cable from ACC1/3/14(RX)-IDU1/2/GbE1(TX) ACC1/3/14(RX)
IPRAN 90002E4 to
Indoor
IPRAN IDU1/2/GbE1(RX)-IPRAN
NR8250#1
ACC1/3/14(TX)-IDU1/2/GbE1(RX) ACC1/3/14(TX)

IPRAN IDU2/2/GbE1(TX)-IPRAN Indoor


OF Cable from
ACC1/3/13(RX)-IDU2/2/GbE1(TX) ACC1/3/13(RX)
IPRAN 90002E4 to
IPRAN IDU2/2/GbE1(RX)-IPRAN Indoor
NR8250#2
ACC1/3/13(TX)-IDU2/2/GbE1(RX) ACC1/3/13(TX)
IPRAN IDU1/2/10GbE1(TX)-IPRAN
OF Cable from Indoor
ACC1/3/19(RX)-IDU1/2/10GbE1(TX) ACC1/3/19(RX)
IPRAN 90002E4 to
IPRAN IDU1/2/10GbE1(RX)-IPRAN
NR8250#1 Indoor
ACC1/3/19(TX)-IDU1/2/10GbE1(RX) ACC1/3/19(TX)
IPRAN IDU2/2/10GbE1(TX)-IPRAN
OF Cable from Indoor
ACC1/3/20(RX)-IDU2/2/10GbE1(TX) ACC1/3/20(RX)
IPRAN 90002E4 to
IPRAN IDU2/2/10GbE1(RX)-IPRAN
NR8250#2 Indoor
ACC1/3/20(TX)-IDU2/2/10GbE1(RX) ACC1/3/20(TX)

 IPRAN-ODF

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 36 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

 Label description and label name


Table 6-4
Label Label Name(IPRAN Side) Label Name(ODF Side) Remark
Description
IPRAN ACC1/3/9-ODF1/0/13 ODF1/0/13-IPRAN ACC1/3/9 Indoor

IPRAN ACC1/3/9-ODF1/0/14 ODF1/0/14-IPRAN ACC1/3/9 Indoor


OF Cable from
IPRAN 90002E4
to ODF IPRAN ACC1/3/10-ODF1/0/15 ODF1/0/15-IPRAN ACC1/3/10 Indoor

IPRAN ACC1/3/10-ODF1/0/16 ODF1/0/16-IPRAN ACC1/3/10 Indoor

IPRAN CSR1/2/1-ODF1/0/13 ODF1/0/13-IPRAN CSR1/2/1 Indoor

OF Cable from IPRAN CSR1/2/1-ODF1/0/14 ODF1/0/14-IPRAN CSR1/2/1 Indoor


IPRAN 6120S to
ODF IPRAN CSR1/2/2-ODF1/0/15 ODF1/0/15-IPRAN CSR1/2/2 Indoor

IPRAN CSR1/2/2-ODF1/0/16 ODF1/0/16-IPRAN CSR1/2/2 Indoor

IPRAN CSR1_Ext/1/1-ODF1/0/17 ODF1/0/17-IPRAN CSR1_Ext/1/1 Indoor

OF Cable from IPRAN CSR1_Ext/1/1-ODF1/0/18 ODF1/0/18-IPRAN CSR1_Ext/1/1 Indoor


IPRAN 6120S
(Exp.Card) to ODF IPRAN CSR1_Ext/1/2-ODF1/0/19 ODF1/0/19-IPRAN CSR1_Ext/1/2 Indoor

IPRAN CSR1_Ext/1/2-ODF1/0/20 ODF1/0/20-IPRAN CSR1_Ext/1/2 Indoor

 ODF-MW(NR8950)
Table 6-5
Label Label Name(ODF Side) Label Name(NR8950 Side) Remark
Description ODF1/0/13-AOU1 Near-End Site ID AOU1 Near-End Site ID to Indoor /
OF Cable from
to Far-End Site ID Far-End Site ID-ODF1/0/13 Outdoor
ODF to NR8950
ODF1/0/14-AOU1 Near-End Site ID AOU1 Near-End Site ID to Indoor /
AOU#1
to Far-End Site ID Far-End Site ID-ODF1/0/14 Outdoor
OF Cable from ODF1/0/15-AOU2 Near-End Site ID AOU2 Near-End Site ID to Indoor /
ODF to NR8950 to Far-End Site ID Far-End Site ID-ODF1/0/15 Outdoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 37 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

AOU#2 ODF1/0/16-AOU2 Near-End Site ID AOU2 Near-End Site ID to Indoor /


to Far-End Site ID Far-End Site ID-ODF1/0/16 Outdoor
ODF1/0/17-AOU3 Near-End Site ID AOU3 Near-End Site ID to Indoor /
OF Cable from
to Far-End Site ID Far-End Site ID-ODF1/0/17 Outdoor
ODF to NR8950
ODF1/0/18-AOU3 Near-End Site ID AOU3 Near-End Site ID to Indoor /
AOU#3
to Far-End Site ID Far-End Site ID-ODF1/0/18 Outdoor

ODF1/0/19-AOU4 Near-End Site ID AOU4 Near-End Site ID to Indoor /


OF Cable from
to Far-End Site ID Far-End Site ID-ODF1/0/19 Outdoor
ODF to NR8950
ODF1/0/20-AOU4 Near-End Site ID AOU4 Near-End Site ID to Indoor /
AOU#4
to Far-End Site ID Far-End Site ID-ODF1/0/20 Outdoor

 Labeling Standard
Figure 6-2

3cm

NR8950 side OF labeling

This label will be put in MW side only.

MW OF cable (NR8950 Side, Outdoor)

3. Ethernet Cable

 Label description and label name

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 38 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Table 6-6
Label Description Label Name Remark

Site Controller-Modem WAN


Site Controller to Modem Indoor
Modem WAN -Site Controller

Modem to IPRAN 90002E4 IPRAN ACC/0/3/0/1-Modem WAN Indoor

Modem to IPRAN 6120S IPRAN CSR/1/2/0/7-Modem WAN Indoor

 Labeling Standard
Figure 6-3

Site controller Site controller


labelling labelling

Ethernet cable for site controller

7 Power and Grounding Cable

7.1 Component Labeling

1. DC breaker Distribution in Master Cabinet

 Label description and label name

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 39 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 7-1

 Split RTA/TTA
Figure 7-2

 Non Split RTA/TTA

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 40 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 7-3

 Labeling Standard
Figure 7-4

IPRAN 9R01

DC breaker labeling

2. Battery Labeling

 Label description and label name


Table 7-1
Label Description Label Name Remark
For String 01 Battery 1 BAT01/1 Indoor
For String 01 Battery 2 BAT01/2 Indoor
For String 01 Battery 3 BAT01/3 Indoor
For String 01 Battery 4 BAT01/4 Indoor
For String 02 Battery 1 BAT02/1 Indoor
For String 02 Battery 2 BAT02/2 Indoor
For String 02 Battery 3 BAT02/3 Indoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 41 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

For String 02 Battery 4 BAT02/4 Indoor

 Labeling Standard
Figure 7-5

BAT01/4 BAT01/1

BAT02/4 BAT02/1

7.2 Cable Labeling

1. AC Power Cable

 Label description and label name


Table 7-2
Label Description Label Name Label Name Remark
AC Power cable from PS-ACPDB to PS-MCabinet-ACPDU to
Indoor/Outdoor
ACPDB to Master Cabinet MCabinet-ACPDU ACPDB
ACPDU
 Labeling Standard

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 42 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Figure 7-6

AC Power Cable
labelling

AC power cable

2. AC Power Cable Color Code Label

 Label description and label name


Figure 7-7

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 43 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

 Labeling Standard
Figure 7-8

AC Power Cable
Color Code Label

3. Battery Power Cable

 Label description and label name


Table 7-3
Label Description Label Name Remark
Main Cabinet Battery String-01 -48V BAT01/-48V Indoor
Main Cabinet Battery String-01 +0V BAT01/+0V Indoor
Main Cabinet Battery String-02 -48V BAT02/-48V Indoor
Main Cabinet Battery String-02 +0V BAT02/+0V Indoor
Extension Cabinet Battery String-03 BAT03/-48V Indoor
-48VExtension Cabinet Battery String-03 +0V BAT03/+0V Indoor

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 44 of 45


Doc No. : BTL P15-PM-QM-STD-LB-001
Site Labeling Guidelines Revision No : V01.5 Issued : 2015-12-27
Template No. :
DocumentType:
Quality Standard Prepared by : Wu Shuzhong

Extension Cabinet Battery String-04 BAT04/-48V Indoor


-48VExtension Cabinet Battery String-04 +0V BAT04/+0V Indoor
Extension Cabinet Battery String-05 BAT05/-48V Indoor
-48VExtension Cabinet Battery String-05 +0V BAT05/+0V Indoor
Extension Cabinet Battery String-06 BAT05/-48V Indoor
-48VExtension Cabinet Battery String-06 +0V BAT05/+0V Indoor

4. Grounding Cable

 Label description and label name


Table 7-4
Label Description Label Name Remark
Grounding of Master cabinet PGND-Master Cabinet Outdoor (2 pcs)
Grounding of Extension cabinet PGND-Extension Cabinet Outdoor
Grounding of BTS rectifier power PGND-Rect Indoor
Main grounding bar of cabinet
system PGND Cabinet Bar Indoor
Grounding of Master cabinet PGND-Cabinet ACPDU Indoor
Grounding
ACPDU of ACPDB
connect connect to
to ACPDB PGND-ACPDB Indoor
Grounding of BTS module
Master cabinet ACPDU PGND-BBU01 Indoor
Grounding of BTS module PGND-BBU02 Indoor
Grounding of BTS module PGND-IPRAN Indoor
Grounding of BTS module PGND-IDU01 Indoor
Grounding of BTS module PGND-IDU02 Indoor
Grounding of BTS module PGND-GPS Tray Indoor
Grounding of BTS module PGND-DCPDU Indoor

 Labeling Standard

The grounding cables have to be labeled on the grounding bar side with the Far-End description

and prefixed with ‘PGND’.


Figure 7-9

Distribution – ZTE, Belltel Confidential to ZTE and Belltel Page 45 of 45