Вы находитесь на странице: 1из 18

Title: Power Supply Cabinet Solutions

Date: 03/2017
Table of Contents

 RCAB-OD-9396
 V1
 V2
 V3
 V4
 RCAB-OD-2818
 RCAB-OD-8330
 RCAB-OD-5720
 Optional Sensors and Accessories
 Optional AC / DC PDUs

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 2
RCAB-OD-9396 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 3
RCAB-OD-9396-V1
 Single door  Air-condition with cooling
capacity 0,6-0,8kW (AC
powered)

 Space for 4 strings of 4x190AH


batteries

 Multiple options for cable


glands (number and type)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 4
RCAB-OD-9396-V2
 Double door  Fan Filter with cooling
capacity > 1.2kW (DC
powered)

 Space for 1 string of 4x150AH


batteries

 Multiple options for cable glands


(number and type)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 5
RCAB-OD-9396-V3
 Single door  Fan Filter with cooling
capacity > 1.2kW (DC
powered)

 Space for 2 strings of 4x150AH


batteries

 Multiple options for cable glands


(number and type)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 6
RCAB-OD-9396-V4
 Double door  Combined Unit of Air-
condition and HEX with
Cooling capacity > 3kW (AC
or DC powered)

 Space for 1 string of 4x190AH


batteries

 Multiple options for cable glands


(number and type)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 7
RCAB-OD-2818 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 8
RCAB-OD-2818

 Air-condition with cooling capacity 1,5kW (AC powered)


 Low Noise Air-condition with cooling capacity 1,5kW (AC and DC
powered)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 9
RCAB-OD-8330 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 10
RCAB-OD-8330 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 11
RCAB-OD-8330 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 12
RCAB-OD-8330 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 13
RCAB-OD-8330
 Double doors  HEX cooling capacity 100
W/K

 Battery case
 Flip down AC PDU
 Multiple options for cable glands
(number and type)

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 14
RCAB-OD-5720 Layout

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 15
RCAB-OD-5720

 Single door

 Space for 1 string of 4x100AH batteries

 Multiple options for cable glands (number and type)

 HEX or Air-condition unit with cooling capacity 0,6kW

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 16
Optional Sensors - Accessories

 Various sensors

Door Vibration Temperature Smoke Flood

PT1000 Fan speed controller with


Temp. sensor Ethernet connectivity for Laptop table / Heater
remote control Document holder

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 17
Optional PDUs

 Customized PDUs for AC and DC


 Optional integrated surge protection modules

This information was prepared by Raycap and is confidential; it may not be copied, reproduced, disclosed or distributed without prior written consent from Raycap. 18

Вам также может понравиться