Вы находитесь на странице: 1из 1

Design of column as per IS-456

Percentage of reinforcement 0.885104 %


Material properties p/fcu 0.0252887
Fcu 35 N/mm2
Fy 500 N/mm2 Pu/(fcu*b*d) 0.004542
w(con) 25 KN/m3
Esteel 200000 N/mm2 Mu/(fcu*b*d^2) ( from table) 0.050948
Member Properties
Moment carrying capacity about shorter dimension 2712.191 KNm
Clear height of column 2.35 m Moment carrying capacity about Larger dimension 1877.67 KNm
Smaller dimension of col 0.9 m
Larger Dimension of col 1.3 m Mx/Mux 0.053831
End Condition 1 My/Muy 0.188531
b 1
Effective height 2.35 m Design Load 22310.9 KN
Le/Ll 2.61111 Short column P/Puz 0.008337
Coefficient of effective cover 0.05
Effective Cover to reinforcement 0.045 m Alpha 1

Loads Check for biaxial bending 0.242363 Design is ok

Factored load = 186 KN

Column Interaction Chart

Reduction factor due to selenderness


0.6
Cr 1
Min. Eccentricities 0.5

Min. Eccentricity along largest dimension 0.02 m 0.4


Pu/Fcubd
Min. Eccentricity along least dimension 0.02 m 0.3
Design Curve
Design Pu/fcubd
0.2
Moments
0.1
Min. Eccentric Moment about least dimension 3.72 KNm
Min. Eccentric Moment about largeset dimension 3.72 KNm 0
0 0.02 0.04 0.06 0.08 0.1 0.12
Actual Moment about least dimension 146 KNm
Mu/Fcubd2
Actual Moment about bigger dimension 354 KNm