Вы находитесь на странице: 1из 6

Myladoor Consultancy Services

Structural Engineers and Architects


#80, Fifth Street Poompuhar Nagar Kolathur Post Chennai, TN
India – 600 099.

Client: Unique Builders, Chennai.


Consultant: Myladoor Consultancy Services, Chennai.

TRIVANDRUM DIVISION
ERNAKULAM - TRIVANDRUM SECTION

PROPOSED CONSTRUCTION OF ROAD OVER BRIDGE


BRIDGE NO. 290 AT km: 58/900-59/000 EXG. 1 x 25150 SPAN ARCH RCC BRIDGE
PROP. 1 x 40000 SK CLEAR SPAN BOWSTRING GIRDER SUPER STRUCTURE
AND 1x11550 SQ ( 18760 SK) CLEAR SPAN PSC SOLID SLAB
BETWEEN ETTUMANOOR & KOTTAYAM STATIONS (NAGAMPADAM).

STAGING FOR BOWSTRING GIRDER SPAN

CLEAR SPAN : 18.760 m (SK)


EFFECTIVE SPAN : 21.100 m
(Alignment - skew 52º)

Doc. No.: Date.: 03-11-2015


MCS/2015/BR.NO.290/BOWSTRING
GIRDER-STAGING
File Path: C:\Documents and Settings\
This document is the property of Myladoor Administrator\ Desktop\ Br.No.290\ PSC
Consultancy Services/Unique Builders and must not SOLID SLAB-Staging.xls
be passed to any person or body not authorized by
us to receive it nor be copied or otherwise be made
use of either in full or in part by such person or body
with our prior permission in writing.

Notes:

Revision Details:

BM AJV JM
Rev. Date Details Init./ Sign Init./Sign Init./Sign
Prepared Checked Approved
STAGING DESIGN FOR BOWSTRING GIRDER FOR BR.NO.290

STAGING DESIGN FOR CASTING PSC SOLID SLAB FOR BR.NO.290

Load calculation :

Dead weight of Main staging = Self weight (Applied in Staad)


Unit weight of green concrete = 2.6 t/m3
Constructiuon load = 0.36 t/m2
Shutters and bracing = 0.125 t/m
Load factor = 1.35 ( Table 3.2, Amendment to IRC:6-2014)
Adding to the effect of variable loads

Deck slab thickness = 1 m


Width of Deck slab = 0.6 m

For 0.6m width = 0.6 x 1 x 2.6


= 1.56 t/m

No. of ISMB = 1 Nos


For 1 ISMB = 1.56 / 1
= 1.56 t/m

Construction load = 0.36 t/m2


Factored variable load = 0.36 x 1.35
= 0.486 t/m2
considering 0.6m width for loads = 0.6 m
= 0.486 x 0.6
= 0.292 t/m

Load due to deck slab,shuttering and construction load


= 1.56 + 0.292 + 0.125
= 1.977 t/m ( Input for STAAD)

Vertical load on Crib

Total no. of cribs = 16 Nos.


Support reaction is obtained from STAAD for the Vertical load on Cribs

1
Myladoor Consultancy Services
STAGING DESIGN FOR BOWSTRING GIRDER FOR BR.NO.290

Checking the adequacy of crib for verical load


Max. load on 1 crib = 0.00 t
Size of plank over the crib = 1 x 1
= 1 m2

Load per 'm' area of crib = 0/1


= 0 t/m2 ( Input for STAAD)

2
Myladoor Consultancy Services
STAGING DESIGN FOR BOWSTRING GIRDER FOR BR.NO.290

STAD INPUT FOR REFERNCE

10
Myladoor Consultancy Services
STAGING DESIGN FOR BOWSTRING GIRDER FOR BR.NO.290

11
Myladoor Consultancy Services

Вам также может понравиться