! Warning: No operating with power on

FR1200 Installation Guide 2.Other Functions


Version: V1.1 Date: Aug, 2011
(1) Wiring Terminals: As the figure below.

1.Equipment Installation Address Switch Setting Address Switch Setting

ON ON

F12 Mounting Paper 1 5


(only for your reference) Terminal

6
Resistance 1 2 3 4 5 6 1 2 3 4 5 6

5
Fi xi ng H ol e

4
In st ru ct io n fo r th e Mo un ti ng P ap er
Be fo re t he d ev ic e is f as te ne d, p le as e
4 ON ON

3
st ic k th e pa pe r to t he p la ce w he re y ou
wa nt t o in st al l it , th en m ak e ho le s an d
la y ca bl es a cc or di ng t o th e mo un ti ng
2 2 6

2
pa pe r.

ON
1

1
1 2 3 4 5 6 1 2 3 4 5 6
Fi xi ng H ol e

Wi ri ng Ho le
Dip Switch ON ON

3 7
1 2 3 4 5 6 1 2 3 4 5 6

+12V
GND
485-
485+

GND
ON ON

(1) Post the mounting template on the (2) Remove the screw on the (3) Take away the back plate. Wiring Terminals 4 8
wall. Drill the holes according to bottom of device. 1 2 3 4 5 6 1 2 3 4 5 6
Back View
the marks on the template (holes
for screws and wiring).
(2) Dip Switch Setting
It is adopted binary coding and little endian. Number 1-4 switches are used to set the 485
address number (device number).
The address number setting by place these 4 switches are shown as the right sheet above.
Number 5 switch is idle.
Number 6 switch is used to se tthe terminal resistance in RS485 communication: Switch
it to ON status, that is add a terminal resistance of 120 ohm between 485+ and 485-.
(3) Manual Reset
If the device does not work properly because of
misoperation or other abnormality, you can use
‘Reset’ function to restart it.
(4) Fix the plastic pad and the back (5) Tighten the screw on the bottom, Reset button
Operation: Remove the black rubber cap, then
plate on the wall according to the fix the device to the back plate. stick the Reset button hole with a sharp tool Bottom View
mounting paper.
(the tip diameter less than 2mm).
3.Connected with Control Panel ! Warning: No operating with power on
(1) Connected as Wiegand Reader Note:
六、wiegand输出 a. Please keep the distance between the device and access control or card reader less than 90 meters
(Please use Wiegand signal extender in long distance or interference environment).
b. To keep the stability of Wiegand signal, connect the device and the access control or card reader in
same ‘GND’ in any case.
SWITCH

PC
RS485
EXT

4. Cautions
RS485
PC

PWR
STATE

ACT
OUT

READER1

(1)Power cable is connected after all the other wiring. If the device is working abnormally, please
READER2

shut down the power first, then make the necessary check . Kindly reminds you that any
hot-plugging may damage the device, and it is not included in the warranty.
Access Control Panel
(2)We recommend the DC 3A/12V power supply. Please contact our technical staff for details.
(2) Connected as inBIO Reader (with External 485)
(3)Please read carefully the terminal description and wiring by rule strictly. Any damage
caused by improper operations will be out of the range of our guarantee.

(4)Keep the exposed part of wire less than 5mm, to avoid unexpected connection.
SWITCH

PC (5)Please connect the ‘GND’ before all the other wiring especially under the environment with much
RS485
EXT

+12V
GND
485-
485+
electrostatic.
RS485
PC

PWR
STATE

ACT
OUT

(6)Do not change the cable type because of long distance between the power and the device.
READER1
READER2

(7) If the 485 communication wire is longer than100 meters, it is needed to set the number 6 dip switch of
Access Control Panel the last reader to ON state, that is parallel a terminal resistance of 120 ohm between 485+ and 485-.