AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

SUMMARY OF BILLS
AKAKI WWTP
Amount
BILL NO. DESCRIPTION ETB
BILL NO.C01 Preliminaries and General
BILL NO.C02A Inlet Sewer, Bypass & Connection Sewer
BILL NO.C02B Valve Chambers
BILL NO.C03 Inlet Chamber, Screen & Grit Channel & FDT01
BILL NO.C04 Lifting Station I & Flow Distribution Chamber FDT02
BILL NO.C05 Flow Distribution Tank (FDT 03)
BILL NO.C06 BILL No. C06 - Anaerobic Ponds
BILL NO.C07 BILL No. C07 - Facultative Ponds
BILL NO.C08 BILL No. C08 - Maturation Ponds
BILL NO.C09 Drying Beds
BILL NO.C10 Sanitary Land Fill
BILL NO.C11 Mechanical Works
BILL NO.C12 Electrical Works
BILL NO.C13 Compound and Ancillary Works
BILL NO.C14 Flood Protection (Embankment)
BILL NO.C15 Out fall Structures

(A) TOTAL OF BILLS


(B) VAT @15% x (A)
GRAND TOTAL (A + B)

1 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works

BILL No. C01 - Preliminaries and General P&G

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS A: GENERAL ITEMS


Contractual Requirements
A110 Performance Bond L.S.
A120 Insurance of the Works and Contractor's Equipment L.S.
A130 Third Party Insurance , including Employer's property L.S.
A190 Insurance for Accidents or Injury to Workmen L.S.
Special Requirements
A900.1 Allow for erection of the Contractor's Camps, offices and other
facilities including mobilization, demobilization and movement off the
works site on completion. Include for all equipment, temporary
measures, machines, tools, facilities for workers, materials, water and
electricity supply etc. for execution of the works.

L.S.
Specified Requirements
A911 Sign Boards
Provide and erect sign boards at the site indicated by the Engineer
and in accordance with the Conditions of Contract and as shown on
the drawings
nr 2
A211.1 Offices
Allow for provision of temporary offices at Akaki Sewage Treatment
Works for the use of the Engineer's Staff, floor area 50 as per details
in the Specifications. Include for maintenance, water supply,
sewerage, drainage, electrical supply, telephone and other facilities.
This offices will be used by the Engineer's staff until the
administration buildings included in the Contract are completed.

L.S.
A211.2 Allow for moving of equipment and furniture from the temporary to the
permanent offices L.S.
A211.3 Maintenance and attendance of the offices for the Engineer's staff for
the duration of the contract. L.S.
A211.4 Maintenance and attendance of the offices for the Engineer's staff
after issue of the Substantial Completion Certificate wk 12
A219 Furniture and equipment for the Engineer's offices as specified. After
completion of the works all furniture and equipment will be renovated
as necessary and revert to the Employer

L.S.
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

2 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works

BILL No. C01 - Preliminaries and General P&G

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A222.1 Allow for telephone and fax services for the Engineer's
Representative. L.S.
A420.3 Carry out cadastral survey for demarcation of the Sewage Treatment
Works boundaries and approval by the respective authorities and
issuance of Title Deed plans.

L.S.
A420.5 Allow for the provision of a camera, films processing, printing and
taking photographs for record purposes as specified or as per
instructions from the Engineer's Representatives.

L.S.
Testing of works
A269.1 Water tightness test for inlet sewer L.S.
A269.2 Water tightness test for screen and grit chambers L.S.
A269.3 Water tightness test for flow distribution tanks L.S.
A269.4 Pressure tests for works pipelines L.S.
A900.2 Training of Staff
Allow for training of Employer's staff during the testing and
commissioning of the plant as specified.
L.S.
A900.3 Allow for provision and maintenance of survey equipment as
specified for the sole use of the Engineer's Representative.
Equipment to revert to the Contractor at the end of the works.

L.S.
A900.4 Other Works, Obligations
The Contractor shall describe in detail hereunder other works,
obligations and things which may be referred to in the Specifications
or which he may consider have been omitted from the Bills of
Quantities and for which he desires to enter a separate charge (the
charge to be carried direct to the amount column). If no separate
charge is made hereunder, the rates in the BOQ shall be held as
covering all expenses for such works, obligations and things.

L.S.
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

3 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C02A - Inlet Sewer, Bypass & Connection Sewer CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS

Commencing surface for excavation shall be the ground level after


site clearing and approximate shaping. It shall include for strutting,
shuttering, stabilizing excavated surfaces and keeping excavations
free of water by bailing out, pumping or other means.
E323 Excavation in Ordinary Soil m3 2,659
E522.1 Site Clearing m2
10,324
E532
Disposal of excavated material, maximum distance of haul not
exceeding 1 km m3 1,662
E634
Filling, general, with selected excavated material other than topsoil
or rock, price Include for compaction as specified m3 1,662

CLASS I: PIPE WORK - PIPES


A - SUPPLY OF PIPES AND FITTINGS (PN 6)
Supply, Transport to Site and Store. The rate to include jointing
materials, rubber rings and cooking oil, or approved equivalent

Excavation, laying, jointing and backfilling is included in 'B' - Pipe


Laying
Reinforced Concrete Flexible Jointed Spigot & Socket Pipes
I230.4 500mm nominal diameter m 1,568
I230.5 600mm nominal diameter m 336
I240.1 700mm nominal diameter m -
I240.2 800mm nominal diameter m 89
I240.3 900mm nominal diameter m 37
I250.1 1000mm nominal diameter m 284
I250.2 1100mm nominal diameter m
I250.3 1200mm nominal diameter m
DCI Flexible Jointed Sewer Pipes
I320.1 250mm nominal diameter m
I320.2 300mm nominal diameter m
I330.1 350mm nominal diameter m
I330.2 400mm nominal diameter m -
I330.3 450mm nominal diameter m
I330.4 500mm nominal diameter m -
I330.5 600mm nominal diameter m 473
I340.1 700mm nominal diameter m -
I340.2 800mm nominal diameter m 662
DCI Fittings
I340.3 DN600mm 900 Bends nr 4
I340.4 DN800mm 90 Bends0 nr 5
I340.5 DN600mm 22 1/2 Bends0 nr 2
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

4 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C02A - Inlet Sewer, Bypass & Connection Sewer CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
B - PIPE LAYING

The rate quoted shall be deemed to include excavation and


backfilling with selected excavated material, from pipe trenches.
The rates shall include disposal of surplus material to tips identified
by the Contractor in liaison with the Local Authority
Reinforced Concrete Flexible Jointed Spigot & Socket Pipes
Nominal diameters 300 - 600 mm in trenches, depth not exceeding
I232 1.5 m m 1,179
I233 - Ditto - but depth 1.5m - 2.0m m 442
I234 - Ditto - but depth 2.0m - 2.5m m 283
Nominal diameters 600 - 900 mm in trenches, depth not exceeding
I242 1.5 m m 30
I243 - Ditto - but depth 1.5m - 2.0m m 96
Nominal diameters 900 - 1200 mm in trenches, depth not exceeding
I252 1.5m m 136
I253 - Ditto - but depth 1.5m - 2.0m m 19
I254 -Nominal
Ditto - but depth 2.0m m
diameters 300 -- 600
2.5mmm in trenches, depth not exceeding 129
I332 1.5 m m 473
Nominal diameters 600 - 900 mm in trenches, depth not exceeding
I342 1.5 m m 662
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

5 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C02A - Inlet Sewer, Bypass & Connection Sewer CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
CLASS K: PIPE WORK - MANHOLES AND ANCILLARIES
K131 nr
1200mm nominal diameter in-situ cast concrete manhole on sewers,
all in accordance with details shown on drawings. Include for
provision and fixing of cast iron step irons and heavy duty triangular
mild steel frame, concrete filled cover as detailed. The rate should
be inclusive of two flexible joints adjacent to the manholes as
detailed and provision of box out and sealing for all pipes. Depth
n.e. 1.5m 5
K132 - Ditto - but depth 1.5m - 2.0m nr 15
K141 nr
1200mm nominal diameter in-situ cast concrete manhole with
backdrop on sewers, all in accordance with details shown on
drawings. Include for provision and fixing of cast iron step irons at
300mm centers staggered as appropriate and heavy duty triangular
cast iron cover and frame, concrete filled cover as detailed. The rate
should be inclusive of two flexible joints adjacent to the manholes as
detailed, provision of box out and sealing for all pipes internal
sulphate resistant plastering, forming half round curved straight
channels and branches in benching. Depth n.e. 1.5m
K142 - Ditto - but depth 1.5m - 2.0m nr 5

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION,


ANCILLARIES TO LAYING AND EXCAVATION
L441 m
Haunch, mass concrete, to pipes nominal diameters not exceeding
200 mm
- Ditto - but nominal diameters 200-300mm
L442
L443 - Ditto - but nominal diameters 300-600mm m 50
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

6 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. C02B - Valve Chambers CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS
Excavation for foundations

Commencing surface for excavation shall be the ground level after site
clearing and approximate shaping. It shall include for strutting,
shuttering, stabilizing excavated surfaces and keeping excavations free
of water by bailing out, pumping or other means.
Site Clearing and removal of top soil maximum depth not exceeding
E311 0.25 m m2 121.7
E323 Excavation in Ordinary Soil depth 0.25 - 1.0 m m3
91
E324 -Ditto but depth 1.0 - 2.0 m m3 202
E325 -Ditto but depth 2.0 - 5.0 m m 3
-
E334 Rock, max. depth 1 - 2 m (provisional sum) m3
E532
Disposal of excavated material, maximum hauling distance < 1.0 km
Approved material shall be retained for filling/backfilling, trimming.
Unsuitable and suitable surplus material shall be disposed on site in
separate stockpiles, as directed by the Engineer m3 354.4
E634 Back filling, general, selected excavated material other than topsoil or
rock, price Include for compaction as specified m3 73.0
E635 Filling General, imported selected material other than topsoil, price
Include for compaction as specified m3 36.5
E637 Supply and placing hard rock on top of selected material m2 75.2

CLASS F: IN SITU CONCRETE


Provision of concrete
Provide materials and mix concrete to the specified class
F232 Designed mix; Grade C15; 20 mm aggregate m3 5.6
F253 Designed mix; Grade C25; 20 mm aggregate m3
66.7

Placing of Concrete
Item includes placing, vibrating and curing of the concrete as specified
Mass concrete Grade C15
F511 Blinding under base slab, thickness 75 mm m3 5.6
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 7 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. C02B - Valve Chambers CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Reinforced Concrete; Grade 25
Bases, footings and ground slabs
F622 Base slab of open channel, thickness 150 - 300 mm m3 17.4
Suspended slabs
F632 Suspended slabs, thickness 150 - 300 mm m3 9.3
Walls
F642 Walls of channel, thickness 200 mm m3 40.0
CLASS G: CONCRETE ANCILLARIES
Item dimensions as per details on the Drawings or as specified
Formwork
G143 External sides of base slab m2 16.6
G215 Soffits to Suspended slabs m 2
86.9
G244 Walls of channel m 2
42.5
G279.1 Small void, for openings of pipes up to dia. 800 mm nr 6.0

Reinforcement; high yield steel bars


Rate to include for cutting, bending, supporting, tying and securing
reinforcement
G523 Deformed, nominal size 10 mm kg 6,153.0
Joints
G651 PVC water stops, average width 230mm m 54.0

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION,


ANCILLARIES TO LAYING AND EXCAVATION

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 8 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaka I Sewage Treatment Works


BILL No. C03 - Inlet Chamber, Screen & Grit Channel CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS
Excavation for foundations

Commencing surface for excavation shall be the ground level after site
clearing and approximate shaping. It shall include for strutting,
shuttering, stabilizing excavated surfaces and keeping excavations free
of water by bailing out, pumping or other means.
E311 Site Clearing and removal of top soil maximum depth not exceeding
0.25 m m2 223.4
E323 Excavation in Ordinary Soil depth 0.25 - 1.0 m m3 164
E324 -Ditto but depth 1.0 - 2.0 m m3
269
E325 -Ditto but depth 2.0 - 5.0 m m3 109
E334 Rock, max. depth 1 - 2 m (provisional sum) m3
E532
Disposal of excavated material, maximum hauling distance < 1.0 km
Approved material shall be retained for filling/backfilling, trimming.
Unsuitable and suitable surplus material shall be disposed on site in
separate stockpiles, as directed by the Engineer m3 682.1
E634 Back filling, general, selected excavated material other than topsoil or
rock, price Include for compaction as specified m3 131.4
E635 Filling General, imported selected material other than topsoil, price
Include for compaction as specified m3 65.7
E637 Supply and placing hard rock on top of selected material m2 108.5

CLASS F: IN SITU CONCRETE


Provision of concrete
Provide materials and mix concrete to the specified class
F232 Designed mix; Grade C15; 20 mm aggregate m3 7.8
F253 Designed mix; Grade C25; 20 mm aggregate m3
71.5

Placing of Concrete
Item includes placing, vibrating and curing of the concrete as specified
Mass concrete Grade C15
F511 Blinding under base slab, thickness 75 mm m3 7.8
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

9 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaka I Sewage Treatment Works


BILL No. C03 - Inlet Chamber, Screen & Grit Channel CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Reinforced Concrete; Grade 25
Bases, footings and ground slabs
F622 Base slab of open channel, thickness 150 - 300 mm m3 15.5
Suspended slabs
F632 Suspended slabs, thickness 150 - 300 mm m3 7.0
Walls
F642 Walls of channel, thickness 200 mm m3 49.0

CLASS G: CONCRETE ANCILLARIES


Item dimensions as per details on the Drawings or as specified
Formwork
G143 External sides of base slab m2 24.2
G215 Soffits to Suspended slabs m2 67.2
G244 Walls of channel m2 57.5
G279.1 Small void, for openings of pipes up to dia. 800 mm nr 6.0

Reinforcement; high yield steel bars


Rate to include for cutting, bending, supporting, tying and securing
reinforcement
G523 Deformed, nominal size 10 mm kg 7,695.0
Joints
G651 PVC water stops, average width 230mm m 116.0
Inserts,
including provision and installation
G832 Inserts, step irons nr 4.0

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION,


ANCILLARIES TO LAYING AND EXCAVATION
Beds, haunches, surrounds
L442 Provide and place mass concrete haunches to the partial flume, size
200-300 mm m 10.0

CLASS M: MISCELLANEOUS METALWORK


Balustrades and Railings
N12
Balustrade Unit 900mm High comprising 40mm Diameter Galvanized
Pipe Top, Middle and Bottom Rails and 40mm Diameter Galvanized
Pipe Balusters Spaced at Maximum 1000mm centers and bottom end
bent, fanged and built into mortise in concrete, including all necessary
Welding.
40 x 40 x 2.5mm thick mild steel angle iron plugged and screwed to
edges. m 30.0
N13 Ladders m 16.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

10 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C04-A - Lifting Station I & Flow Distribution Chamber II CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS
Excavation for foundations

Commencing surface for excavation shall be the ground level after site
clearing and approximate shaping. It shall include for strutting, shuttering,
stabilizing excavated surfaces and keeping excavations free of water by
bailing out, pumping or other means.
E311 Site Clearing and removal of top soil maximum depth not exceeding 0.25 m m2 286.8
E323 Excavation in Ordinary Soil depth 0.25 - 1.0 m m 3
106
E324 -Ditto but depth 1.0 - 2.0 m m 3
177
E325 -Ditto but depth 2.0 - 5.0 m m3 151
E334 Rock, max. depth 1 - 2 m (provisional sum) m3
E532
Disposal of excavated material, maximum hauling distance < 1.0 km
Approved material shall be retained for filling/backfilling, trimming.
Unsuitable and suitable surplus material shall be disposed on site in
separate stockpiles, as directed by the Engineer m3 582.7
E634 Back filling, general, selected excavated material other than topsoil or rock,
price Include for compaction as specified m3 148.7
E635 Filling General, imported selected material other than topsoil, price Include
for compaction as specified m3 49.6
E637 Supply and placing hard rock on top of selected material m 2
117.8

CLASS F: IN SITU CONCRETE


Provision of concrete
Provide materials and mix concrete to the specified class
F232 Designed mix; Grade C15; 20 mm aggregate m3 8.8
F253 Designed mix; Grade C25; 20 mm aggregate m3 169.0
Placing of Concrete
Item includes placing, vibrating and curing of the concrete as specified
Mass concrete Grade C15
F511 Blinding under base slab, thickness 75 mm m3 8.8
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

11 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C04-A - Lifting Station I & Flow Distribution Chamber II CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Reinforced Concrete; Grade 25
Bases, footings and ground slabs
F622.1 Footing m3 14.3
F622.2 Base slab of troughs, thickness 150 - 300 mm m3 20.9
Suspended slabs
F632 Suspended slabs, thickness 150 - 300 mm m3 81.3
Walls
F642 Walls of trough & channel, thickness 150-300 mm m3 24.0
Columns
F652 Columns with cross-sectional area 0.03-0.1m2 m3 14.5
Beams
F662 Beams with cross-sectional area 0.03-0.1m2 m3 14.0
CLASS G: CONCRETE ANCILLARIES
Item dimensions as per details on the Drawings or as specified
Formwork
G143 External sides of base slab & footings m2 38.1
G215 Soffits to Suspended slabs m2 388.8
G243 Columns & Beams m2 339.0
G244 Walls m2 468.0
G279.1 Small void, for openings of pipes up to dia. 800 mm nr 6.0
Reinforcement :- Rate to include for cutting, bending, supporting, tying and
securing reinforcement
G511 Plain rounded nominal size 6 mm kg 599.0
G522 Deformed, nominal size 8 mm kg 147.0
G523 Deformed, nominal size 10 mm kg 3,040.0
G524 Deformed, nominal size 12 mm kg 9,109.0
G525 Deformed, nominal size 14 mm kg 2,347.0
G526 Deformed, nominal size 16 mm kg 3,429.0
Joints
G651 PVC water stops, average width 230mm m 91.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

12 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C04-A - Lifting Station I & Flow Distribution Chamber II CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Plastering
5mm Thick Gauged Cement Plaster as described internally on :-
G815.1 Soffits to Suspended slabs m2 388.8
G815.2 Columns & Beams m2 169.5
G815.3 Walls m2 234.0
Screeds

Bonded cement and sand (1:4) screed bed in one coat, well bonded to
concrete base as described:-
G816.1 Walls m2 234.0
Inserts,
including provision and installation
G832 Inserts, step irons nr 3.0

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION, ANCILLARIES


TO LAYING AND EXCAVATION
Concrete C 25 in stools and thrust blocks
L733 Nominal bore not exceeding 300 - 400 mm, volume n. e. 0.2 - 0.5 m3 nr 6.0

CLASS M: MISCELLANEOUS METALWORK


Balustrades and Railings
N11
Balustrade Unit 900mm High comprising 40mm Diameter Galvanized Pipe
Top, Middle and Bottom Rails and 40mm Diameter Galvanized Pipe
Balusters Spaced at Maximum 1000mm centers and bottom end bent,
fanged and built into mortise in concrete, including all necessary Welding.
40 x 40 x 2.5mm thick mild steel angle iron plugged and screwed to edges
of staircase treads. m 36.0
Gantry Girder
N163
Erection of gantry girder made out of 305 x 165 x 54 kilogram's per meter
universal beam and chain block on to the pump house structure. Kg 2,500.0

CLASS U: BRICKWORK, BLOCK WORK AND MASONRY


L421 200mm Thick HCB Walling With Concrete Blocks, Bedded, Jointed and
Pointed in Cement Mortar (1:5):- m2 148.1
L731 500mm Thick Foundation Masonry Walling With Natural Stone Block,
Bedded and pointed in Cement Mortar (1:5) m3 52.7
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

13 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C04-A - Lifting Station I & Flow Distribution Chamber II CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
CLASS W: ROOFING COVERING
W371.1 Roof tiles m2 56.2
W371.2 Ridge capping including bedding and pointing in cement sand (1:4) mortar
with coloring to match color of tiles m 44.0
W371.3 Hip capping including bedding and pointing in cement sand (1:4) mortar
with coloring to match color of tiles m 44.0
CLASS Z: BUILDING WORKS INCIDENTAL TO CIVIL ENGINEERING
WORKS
CARPENTRY AND JOINERY

Roof Timbers, Double Pitch Roof Truss in Sawn Cypress Seasoned and
Pressure Impregnated with Wood Preservative and timber joints with bolted
and nailed connections to the Engineer's approval :-
Z114.1
Equal truss 6300 mm clear span and 1270mm high with 600mm eaves
projection, in 150 x 50mm rafters and 100 x 50mm struts and ties nr 9.0
Z114.2 150 x 50mm Intermediate rafters m 580.0
Z114.3 150 x 50mm Hip rafters m 38.0
Z114.4 150 x 50mm Valley rafters m 24.0
Z114.5 150 x 50mm Purlins m 200.0
Z114.6 180
100 xx 50mm
50mm Wall
Ridgeplate
board
tied to wall with 20 s.w.g. hoop iron at 900mm m 44.0
Z114.7 centers m 116.0
Z114.8 Scarfed joint to 150 x 50mm timber member Nr 136.0
Z114.9 225 x 40mm Fascia board m 44.0
Windows, Doors & Glazing

Supply and Fix the following Standard Section Horizontal Bar Type Steel
Casement Windows & Doors, complete with opening accessories including
bedding and pointing around frames in cement mortar:-
Z321.1
Window size 1797 x 1197mm high with 1 No. fixed and 2 No. side-hung
opening lights, and with 1 No. top-hung ventilator with permanent ventilator
hood over nr 6.0
Z321.2 Window size 1797 x 597mm high with 2 No. fixed lights, and with 1 No. top-
hung ventilator with permanent ventilator hood over nr 4.0
Z323 Door size 1200 x 2100 mm high in one panel nr 2.0
Z351 4mm Thick Clear Sheet Glass And Glazing to Steel Casements with putty
in panes:- m2 19.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

14 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-A - Flow Distribution Tank (FDT 02) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS
Excavation for foundations

Commencing surface for excavation shall be the ground level after site
clearing and approximate shaping. It shall include for strutting, shuttering,
stabilizing excavated surfaces and keeping excavations free of water by
bailing out, pumping or other means.
E311 Site Clearing and removal of top soil maximum depth not exceeding 0.25 m m2 143.8
E323 Excavation in Ordinary Soil depth 0.25 - 1.0 m m3
30
E324 -Ditto but depth 1.0 - 2.0 m m3
47
E325 -Ditto but depth 2.0 - 5.0 m m3 33
E334 Rock, max. depth 1 - 2 m (provisional sum) m3
E532
Disposal of excavated material, maximum hauling distance < 1.0 km
Approved material shall be retained for filling/backfilling, trimming.
Unsuitable and suitable surplus material shall be disposed on site in
separate stockpiles, as directed by the Engineer m3 149.3
E634 Back filling, general, selected excavated material other than topsoil or rock,
price Include for compaction as specified m3 36.1
E635 Filling General, imported selected material other than topsoil, price Include
for compaction as specified m3 12.0
E637 Supply and placing hard rock on top of selected material m2
21.3

CLASS F: IN SITU CONCRETE


Provision of concrete
Provide materials and mix concrete to the specified class
F232 Designed mix; Grade C15; 20 mm aggregate m3 1.6
F253 Designed mix; Grade C25; 20 mm aggregate m3 59.7
Placing of Concrete
Item includes placing, vibrating and curing of the concrete as specified
Mass concrete Grade C15
F511 Blinding under base slab, thickness 75 mm m3 1.6
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

15 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-A - Flow Distribution Tank (FDT 02) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Reinforced Concrete; Grade 25
Bases, footings and ground slabs
F622.1 Footing m3 8.9
F622.2 Base slab, thickness 150 - 300 mm m3 -
Suspended slabs
F632 Suspended slabs, thickness 150 - 300 mm m3 21.8
Walls
F642 Walls , thickness 150-300 mm m3 12.0
Columns
F652 Columns with cross-sectional area 0.03-0.1m2 m3 4.4
Beams
F662 Beams with cross-sectional area 0.03-0.1m2 m3 12.6
CLASS G: CONCRETE ANCILLARIES
Item dimensions as per details on the Drawings or as specified
Formwork
G143 External sides of base slab & footings m2 22.2
G215 Soffits to Suspended slabs m2 140.0
G243 Columns & Beams m2 187.0
G244 Walls m2 107.0
G279.1 Small void, for openings of pipes up to dia. 800 mm nr 10.0
Reinforcement :- Rate to include for cutting, bending, supporting, tying and
securing reinforcement
G511 Plain rounded nominal size 6 mm kg 373.0
G522 Deformed, nominal size 8 mm kg 471.0
G523 Deformed, nominal size 10 mm kg 302.0
G524 Deformed, nominal size 12 mm kg 3,385.0
G525 Deformed, nominal size 14 mm kg 2,369.0
G526 Deformed, nominal size 16 mm kg 716.0
Joints
G651 PVC water stops, average width 230mm m 25.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

16 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-A - Flow Distribution Tank (FDT 02) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Plastering
5mm Thick Gauged Cement Plaster as described internally on :-
G815.1 Soffits to Suspended slabs m2 140.0
G815.2 Columns & Beams m2 93.5
G815.3 Walls m2 53.5
Screeds

Bonded cement and sand (1:4) screed bed in one coat, well bonded to
concrete base as described:-
G816.1 Walls m2 53.5
Inserts,
including provision and installation
G832 Inserts, step irons nr 6.0

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION, ANCILLARIES


TO LAYING AND EXCAVATION
Concrete C 25 in stools and thrust blocks
L733 Nominal bore not exceeding 300 - 400 mm, volume n. e. 0.2 - 0.5 m3 nr 2.0

CLASS M: MISCELLANEOUS METALWORK


Balustrades and Railings
N11 Balustrade Unit 900mm High comprising 40mm Diameter Galvanized Pipe
Top, Middle and Bottom Rails and 40mm Diameter Galvanized Pipe
Balusters Spaced at Maximum 1000mm centers and bottom end bent,
fanged and built into mortise in concrete, including all necessary Welding.
40 x 40 x 2.5mm thick mild steel angle iron plugged and screwed to edges
of staircase treads. m 10.0
N13 Ladders m 6.0

CLASS U: BRICKWORK, BLOCKWRK AND MASONRY


L421 200mm Thick HCB Walling With Concrete Blocks, Bedded, Jointed and
Pointed in Cement Mortar (1:5):- m2 70.9
L731 500mm Thick Foundation Masonry Walling With Natural Stone Block,
Bedded and pointed in Cement Mortar (1:5) m3 15.3
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

17 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-A - Flow Distribution Tank (FDT 02) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
CLASS W: ROOFING COVERING
W371.1 Roof tiles m2 75.6
W371.2 Ridge capping including bedding and pointing in cement sand (1:4) mortar
with coloring to match color of tiles m 36.0
W371.3 Hip capping including bedding and pointing in cement sand (1:4) mortar
with coloring to match color of tiles m 30.0
CLASS Z: BUILDING WORKS INCIDENTAL TO CIVIL ENGINEERING
WORKS
CARPENTRY AND JOINERY

Roof Timbers, Double Pitch Roof Truss in Sawn Cypress Seasoned and
Pressure Impregnated with Wood Preservative and timber joints with bolted
and nailed connections to the Engineer's approval :-
Z114.1
Equal truss 6300 mm clear span and 1270mm high with 600mm eaves
projection, in 150 x 50mm rafters and 100 x 50mm struts and ties nr 6.0
Z114.2 150 x 50mm Intermediate rafters m 400.0
Z114.3 150 x 50mm Hip rafters m 26.0
Z114.4 150 x 50mm Valley rafters m 16.0
Z114.5 150 x 50mm Purlins m 140.0
Z114.6 180 x 50mm Ridge board m 30.0
100 x 50mm Wall plate tied to wall with 20 s.w.g. hoop iron at 900mm
Z114.7 centers m 80.0
Z114.8 Scarfed joint to 150 x 50mm timber member Nr 94.0
Z114.9 225 x 40mm Fascia board m 30.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

18 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-A - Flow Distribution Tank (FDT 02) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CARPENTRY AND JOINERY

Roof Timbers, Double Pitch Roof Truss in Sawn Cypress Seasoned and
Pressure Impregnated with Wood Preservative and timber joints with bolted
and nailed connections to the Engineer's approval :-
Z114.1
Equal truss 6300 mm clear span and 1270mm high with 600mm eaves
projection, in 150 x 50mm rafters and 100 x 50mm struts and ties nr 7.0
Z114.2 150 x 50mm Intermediate rafters m 400.0
Z114.3 150 x 50mm Hip rafters m 28.0
Z114.4 150 x 50mm Valley rafters m 18.0
Z114.5 150 x 50mm Purlins m 150.0
Z114.6 180 x 50mm Ridge board m 30.0
100 x 50mm Wall plate tied to wall with 20 s.w.g. hoop iron at 900mm
Z114.7 centers m 80.0
Z114.8 Scarfed joint to 150 x 50mm timber member Nr 94.0
Z114.9 225 x 40mm Fascia board m 30.0
Windows, doors & Glazing

Supply and Fix the following Standard Section Horizontal Bar Type Steel
Casement Windows & Doors, complete with opening accessories including
bedding and pointing around frames in cement mortar:-
Z321.1
Window size 1797 x 1197mm high with 1 No. fixed and 2 No. side-hung
opening lights, and with 1 No. top-hung ventilator with permanent ventilator
hood over nr 2.0
Z321.2 Window size 1797 x 597mm high with 2 No. fixed lights, and with 1 No. top-
hung ventilator with permanent ventilator hood over nr 8.0
Z323 Door size 1000 x 2100 mm high in one panel nr 1.0
Z351 4mm Thick Clear Sheet Glass And Glazing to Steel Casements with putty
in panes:- m2 14.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED TO SUMMARY

19 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-B - Flow Distribution Tank (FDT 03) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

CLASS E: EARTHWORKS
Excavation for foundations

Commencing surface for excavation shall be the ground level after site
clearing and approximate shaping. It shall include for strutting, shuttering,
stabilizing excavated surfaces and keeping excavations free of water by
bailing out, pumping or other means.
E311 Site Clearing and removal of top soil maximum depth not exceeding 0.25 m m2 51.9
E323 Excavation in Ordinary Soil depth 0.25 - 1.0 m m 3
11
E324 -Ditto but depth 1.0 - 2.0 m m 3
18
E325 -Ditto but depth 2.0 - 5.0 m m3 13
E334 Rock, max. depth 1 - 2 m (provisional sum) m3
E532
Disposal of excavated material, maximum hauling distance < 1.0 km
Approved material shall be retained for filling/backfilling, trimming.
Unsuitable and suitable surplus material shall be disposed on site in
separate stockpiles, as directed by the Engineer m3 56.7
E634 Back filling, general, selected excavated material other than topsoil or rock,
price Include for compaction as specified m3 13.0
E635 Filling General, imported selected material other than topsoil, price Include
for compaction as specified m3 4.3
E637 Supply and placing hard rock on top of selected material m 2
6.7

CLASS F: IN SITU CONCRETE


Provision of concrete
Provide materials and mix concrete to the specified class
F232 Designed mix; Grade C15; 20 mm aggregate m3 0.5
F253 Designed mix; Grade C25; 20 mm aggregate m3 11.0
Placing of Concrete
Item includes placing, vibrating and curing of the concrete as specified
Mass concrete Grade C15
F511 Blinding under base slab, thickness 75 mm m3 0.5
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

20 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-B - Flow Distribution Tank (FDT 03) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Reinforced Concrete; Grade 25
Bases, footings and ground slabs
F622.1 Footing m3 2.8
F622.2 Base slab, thickness 150 - 300 mm m3 -
Suspended slabs
F632 Suspended slabs, thickness 150 - 300 mm m3 3.0
Walls
F642 Walls , thickness 150-300 mm m3 3.0
Columns
F652 Columns with cross-sectional area 0.03-0.1m2 m3 1.1
Beams
F662 Beams with cross-sectional area 0.03-0.1m2 m3 1.1
CLASS G: CONCRETE ANCILLARIES
Item dimensions as per details on the Drawings or as specified
Formwork
G143 External sides of base slab & footings m2 8.7
G215 Soffits to Suspended slabs m2 34.0
G243 Columns & Beams m2 28.0
G244 Walls m2 30.2
G279.1 Small void, for openings of pipes up to dia. 800 mm nr 10.0
Reinforcement :- Rate to include for cutting, bending, supporting, tying and
securing reinforcement
G511 Plain rounded nominal size 6 mm kg 48.0
G522 Deformed, nominal size 8 mm kg 64.0
G523 Deformed, nominal size 10 mm kg 70.0
G524 Deformed, nominal size 12 mm kg 378.0
G525 Deformed, nominal size 14 mm kg 432.0
G526 Deformed, nominal size 16 mm kg 383.0
Joints
G651 PVC water stops, average width 230mm m 12.0
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

21 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C05-B - Flow Distribution Tank (FDT 03) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Plastering
5mm Thick Gauged Cement Plaster as described internally on :-
G815.1 Soffits to Suspended slabs m2 34.0
G815.2 Columns & Beams m2 14.0
G815.3 Walls m2 15.1
Screeds
Bonded cement and sand (1:4) screed bed in one coat, well bonded to
concrete base as described:-
G816.1 Walls m2 15.1
Inserts,
including provision and installation
G832 Inserts, step irons nr 6.0

CLASS L: PIPE WORK - SUPPORTS AND PROTECTION, ANCILLARIES


TO LAYING AND EXCAVATION
Concrete C 25 in stools and thrust blocks
L733 Nominal bore not exceeding 300 - 400 mm, volume n. e. 0.2 - 0.5 m3 nr 2.0

CLASS M: MISCELLANEOUS METALWORK


Balustrades and Railings
N11 Balustrade Unit 900mm High comprising 40mm Diameter Galvanized Pipe
Top, Middle and Bottom Rails and 40mm Diameter Galvanized Pipe
Balusters Spaced at Maximum 1000mm centers and bottom end bent,
fanged and built into mortise in concrete, including all necessary Welding.
40 x 40 x 2.5mm thick mild steel angle iron plugged and screwed to edges
of staircase treads. m 10.0
N13 Ladders m 6.0

CLASS U: BRICKWORK, BLOCK WORK AND MASONRY


L731 500mm Thick Foundation Masonry Walling With Natural Stone Block,
Bedded and pointed in Cement Mortar (1:5) m3 3.3
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED TO SUMMARY

22 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C06 - Anaerobic Ponds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 Earthwork: Anaerobic Ponds
Clearing and Grubbing including the top 20cm organic materials and
1.10 m2 3,500
vegetations
1.20 Common bulk excavation for all depths m3 78,000
1.30 Bulk excavation on soft rock for all depths m3 250
1.40 Bulk excavation on hard rock for all depths m 3
150
1.50 Disposal of excavated materials within 5km distance m3 78,700
Compaction and fill in successive layers to form embankment and platform
1.60 m3 400
with selected excavated material
Compaction and fill in successive layers to form embankment and platform
1.70 m3 2,500
with selected imported material
Supply and place 300mm thick stone pitching for some parts of near gullies
1.80 260
& outer slopes m2
Geomembrane

Supply and lay 1.5mm thick, double side-textured and UV-resistant HDPE
geomembrane waterproofing as per the specifications. Seams and contacts
1.90 m2 24,500
with concrete surfaces shall be fixed to be water tight, durable and strong
for slippage. Area is measured net excluding overlaps.

2 Structures and Others


Inlet structures
Supply and construct inlet structure as show in the drawing. Price includes
2.1 earthworks, hardcore, lean concrete, concrete, formworks, reinforcement No 3
steels, masonry, etc
Outlet structures
Supply and construct inlet structure as show in the drawing. Price includes
2.2 earthworks, hardcore, lean concrete, concrete, formworks, reinforcement No 3
steels, masonry, etc

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED TO SUMMARY

BOQ Page 23 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C07 - Facultative Ponds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 Earthwork: Facultative Pond
Clearing and Grubbing including the top 20cm organic materials and
1.1 m2 44,900
vegetations
1.2 Common bulk excavation for all depths m3 280,700
1.3 Bulk excavation on soft rock for all depths m 3
300
1.4 Bulk excavation on hard rock for all depths m 3
200
1.5 Disposal of excavated materials within 5km distance m 3
289,680
Compaction and fill in successive layers to form embankment and
1.6 m3 500
platform with selected excavated material
Compaction and fill in successive layers to form embankment and
1.7 m3 50,700
platform with selected imported material
Supply and place 300mm thick stone pitching for some parts of near
1.8 940
gullies & outer slopes m2
Geomembrane

Supply and lay 1.5mm thick, double side-textured and UV-resistant


HDPE geomembrane waterproofing as per the specifications. Seams
1.9 and contacts with concrete surfaces shall be fixed to be water tight, m2 196,200
durable and strong for slippage. Area is measured net excluding
overlaps.

2 Structures and Others


Inlet structures
Supply and construct inlet structure as show in the drawing. Price
2.1 includes earthworks, hardcore, lean concrete, concrete, formworks, No 4
reinforcement steels, masonry, etc
Outlet structures
Supply and construct inlet structure as show in the drawing. Price
2.2 includes earthworks, hardcore, lean concrete, concrete, formworks, No 4
reinforcement steels, masonry, etc

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED TO SUMMARY

BOQ Page 24 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C08 - Maturation Ponds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1.0 Earthwork: Maturation Pond
Clearing and Grubbing including the top 20cm organic materials and
1.1 m2 10,600
vegetations
1.2 Common bulk excavation for all depths m3 123,000
1.3 Bulk excavation on soft rock for all depths m 3
400
1.4 Bulk excavation on hard rock for all depths m3 100
1.5 Disposal of excavated materials within 5km distance m 3
125,120
Compaction and fill in successive layers to form embankment and platform
1.6 m3 500
with selected excavated material
Compaction and fill in successive layers to form embankment and platform
1.7 m3 21,000
with selected imported material
Supply and place 300mm thick stone pitching for some parts of near gullies
1.8 770
& outer slopes m2
Geomembrane

Supply and lay 1.5mm thick, double side-textured and UV-resistant HDPE
geomembrane waterproofing as per the specifications. Seams and contacts
1.9 m2 94,600
with concrete surfaces shall be fixed to be water tight, durable and strong
for slippage. Area is measured net excluding overlaps.

2.0 Structures and Others


Inlet Structures
Supply and construct inlet structure as show in the drawing. Price includes
2.1 earthworks, hardcore, lean concrete, concrete, formworks, reinforcement No 4
steels, masonry, etc
Outlet Structures
Supply and construct inlet structure as show in the drawing. Price includes
2.2 earthworks, hardcore, lean concrete, concrete, formworks, reinforcement No 4
steels, masonry, etc

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED TO SUMMARY

BOQ Page 25 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C09 - Drying Beds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 Sand Drying Beds Earthworks
1.1 Common bulk excavation in ordinary soil, for all depths m³ 17307.00
1.2 Bulk excavation in soft rock, for all depths m³ 265.00
1.3 Bulk excavation in hard rock, for all depths m³ 88.00

Compaction and fill in successive layers to form embankment and platform


with approved selected excavated material. Cost includes stockpiling and
1.4 inter site hauling. m³ 200.00
Compaction and fill in successive layers to form embankment and platform
1.5 with selected imported materials. m³ 150.00
1.6 Disposal of excavated surplus and unsuitable materials within 5km m³ 17460.00
2 Geomembrane, Filter and Pipe Materials

Supply and lay 1.5mm thick, double side-textured and UV-resistant HDPE
geomembrane waterproofing as per the specifications. Seams and contacts
with concrete surfaces shall be fixed to be water tight, durable and strong
for slippage. Area is measured net excluding overlaps.
2.1 m2 8627.00
Supply and compact about 100mm thick non-expansive clay over the the
2.2 geomembrane m3 740.00
Provide and place 200mm thick basaltic or granitic crushed or natural sand
2.3 filter (0.8-1.5mm diam) over the gravel layer. m³ 1480.00

Provide and place 300 to 500mm thick gravel filter (top 150mm: 3-6mm
diam & the remaining 150mm thick 6-15mm diam) below the sand bed and
2.4 around the perforated pipe m³ 3104.30
Supply and lay PN 6, 150mm ND uPVC perforated pipes in the gravel beds. m
2.5 Price includes fittings, glues and necessary accessories. 747.40

Supply and lay PN 6, 150mm ND uPVC pipes outside of the gravel beds.
Price includes fittings, glues, earthworks, bedding and necessary m
2.6 accessories. 70.30
Supply and lay PN 6, 200mm ND uPVC collector pipes. Price includes m
2.7 fittings, glues, earthworks, bedding and necessary accessories. 330.00

Supply and lay PN 6, 150mm ND DCI sludge feeder pipes. Price includes
fittings, gaskets, glues, earthworks, bedding and necessary accessories for
2.8 installation. m 325.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 26 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C09 - Drying Beds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

Supply and lay PN 6, 100mm ND DCI distribution channel spouts. Price


2.9 includes fittings, gaskets, glues and necessary accessories for installation. m 370.00

Supply and fix PN 6, 100mm ND DCI gate valves for the spout as shown in
the drawing. Price includes fittings, gaskets, glues and necessary
2.1 accessories to fit to the 100mm DN DCI spout pipes. N0 740.00

Supply and fix PN 6, 150mm ND DCI gate valves for sludge feeder pipes as
shown in the drawing. Price includes fittings, gaskets, glues and necessary
2.11 accessories to fit to the 150mm DN DCI sludge feeder pipes. No 124.00
3 Concrete Walls and Distribution Channels
Earthworks
3.1 Common bulk excavation in ordinary soil for strip footing, for all depths m³ 7728.00
3.2 Bulk excavation in soft rock, for all depths m³ 250.00
3.3 Bulk excavation in hard rock for strip footing, for all depths m³ 70.00

Compaction and fill in successive layers to form embankment and platform


with approved selected excavated material. Cost includes stockpiling and
3.4 inter site hauling. m³ 614.00
Compaction and fill in successive layers to strip footings with selected
3.5 imported materials. m³ 2176.00
3.6 Disposal of excavated surplus and unsuitable materials within 5km m³ 2457.00
Concrete Works
3.7 5 cm thick lean concrete C-5 under footing m2 803.00
3.8 C-25 concrete in strip footings m 3
489.88
3.9 Ditto, but in foundation walls m3 659.04

3.1 Ditto, but in flow distribution channels including bottom channel chamfering m3 115.51

Ditto, but precast flow distribution channels cover in a meter length & 0.65m
3.11 wide as shown in the drawing (including reinforcement and formwork) No 4662.00
Sawn zigba form work
3.12 To sides of footings m2 1210.00
3.13 To sides of foundation walls and flow distribution channels m2 6670.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 27 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C09 - Drying Beds CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

Mild steel rod reinforcement, cutting, bending, tying & placing in position
3.14 Diam. 8mm deformed kg 9790.00
3.15 Diam. 10mm deformed kg 80160.00
4 Masonry Manholes & Valve Chambers

Supply and construct 60cm x60cm entrance opening & 50cm thick masonry
manholes for the sand drying bed supernatant. Depth variable (2-3.5m).
Cost includes earthworks, RC 5cm thick concrete cover, ladder, bed
4.1 channeling and cover lock arrangement. No 22.00

Supply and construct 60cm x60cm entrance opening masonry valve


chamber for the sand drying bed sludge feeder. Depth 1.2m. Cost includes
4.2 earthwork, RC 5cm thick concrete cover and cover lock arrangement. No 22.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED TO SUMMARY

BOQ Page 28 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL No. C10 - Sanitary Landfill CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 EARTHWORKS
Clearing and Grubbing including the top 20cm organic materials and
1.1 m2 880 7
vegetations
1.2 Common bulk excavation for all depths m3 8,160 40
1.3 Bulk excavation on soft rock for all depths m3 1,530 70
1.4 Bulk excavation on hard rock for all depths m3 510 250
1.5 Disposal of excavated materials within 5km distance m3 9,626 60
Compaction and fill in successive layers to from embankment and platform
1.6 m3 750 40
with selected excavated material
Compaction and fill in successive layers to from embankment and platform
1.7 m3 60 60
with selected imported material
Supply and place 300mm thick stone pitching for some parts of gullies and
1.8 100 300
outer slopes m2
Geomembrane

Supply and lay 1.5mm thick, double side-textured and UV-resistant HDPE
geomembrane waterproofing as per the specifications. Seams and contacts
1.8 m2 4,400 110
with concrete surfaces shall be fixed to be water tight, durable and strong
for slippage. Area is measured net excluding overlaps.

2.0 PIPE WORKS

Supply and laying PN 6 uPVC perforated pipe draining to the facultative


ponds. The perforated pipe shall be surrounded by two layers of filters with
2.1 minimum thickness of 20cm each. The rate quoted shall be deemed to
include pipe supplying, earthworks, filter layers, laying pipes and jointing of
fittings (Y-junction and cap, flexible joint and rubber rings), etc

a) DN150mm m 60 410
b) Ditto but none perforated and without filter materials (outfall pipes) m 60 370
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED TO SUMMARY

BOQ Page 29 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


Summary of Electro Mechanical Works - BILL NO. 11 & BILL NO. 12 E & M WORKS

Amount Foreign % of Foreign


BILL NO. DESCRIPTION ETB Currency Currency
BILL NO.C11 MECHANICAL WORKS
M1000 - General Items, Erection, Testing & Commissioning
M2000 - Inlet Bypass & Screen & Grit Chamber
M3000 - Flow Distribution tank 01 at Grit Channel
M4000 - Lifting Station 01 & Flow Distribution Tank 02
M5000 - Mobile Desludging System
M6000 - Flow Distribution Tank 03
TOTAL OF BILL NO.11 CARRIED TO SUMMARY -

BILL NO.C12 ELECTRICAL WORKS


E1000 - WWTP Electrical
E2000 - Standby Power
TOTAL OF BILL NO. 12 CARRIED TO SUMMARY -

08/02/2020 BOQ 30 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M1000 - General Items, Erection, Testing & Commissioning

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign


No. ETB ETB Currency Currency
M1100 Treatment Plant Compound
M1101 Allow for the erection of the whole of the plant LS 1.0
M1102 Allow for Tests on Completion LS 1.0
M1103 Allow for the period of continuous operation LS 1.0
M1104 Allow for the period of instruction LS 1.0
M1105 Allow for putting into a fully operational condition all plant LS 1.0
M1200 Civil Works Associated Services
M1201 Allow for foundations associated with the road lighting columns LS 1.0
M1202 Allow for the sealing of all cable ducts as required and specified LS 1.0
M1203 Allow for foundations associated with floodlighting columns LS 1.0
M1204 Allow for all trenching, sanding, back-fillings, protection. compaction, carting away surplus and
reinstatement of existing surface as necessary, to meet the requirements of all services LS 1.0
M1205 Allow for all builders works associated with the electrical and mechanical installations LS 1.0
M1206 Allow for the modification of the civil structure LS 1
M1207
The Contractor shall allow here as one L.S for any other foundation/builders works details he
considers necessary for the completion of the Mechanical and Electrical Services. The
Contractor shall be required to provide ail necessary details sufficiently LS 1
M1300 Drawings and Manuals
M1301 Allow for the submission of all contractor's drawings in accordance with the contract LS 1
M1302 Allow for the preparation of As Built Drawings LS 1
M1303 Allow for the preparation of Operation and Maintenance manuals LS 1
M1304 Allow for the preparation of maintenance logbooks for the complete electro-mechanical plant. LS 1
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 31 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M1000 - General Items, Erection, Testing & Commissioning

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign


No. ETB ETB Currency Currency
M1400 Tools and spare parts
M1401 Allow for the supply of workshop equipment as specified LS 1
M1402 Allow for the supply of special tools as listed in the Data Schedules LS 1
M1500 Miscellaneous and General Obligations
M1501 Allow for all costs and expenses involved in sending staff to site for erection, testing and
commissioning and installation, including fares, allowances, medical expenses, insurance and
repatriation LS 1
M1502 Allow for all local costs involved in maintaining supervisory and erection staff during erection,
operation and maintenance periods including housing and transport. LS 1
M1503 Allow for special erection plant not available in Ethiopia LS 1
M1504 Allow for the provision of padlocks and keys for all cabinets, inter-locks, lock-off switches etc. LS 1
M1505 Allow for Insurance of works in accordance with the Contract LS 1
M1506 Allow for all other insurance's LS 1
M1507 Allow for the cost of the Performance Bond required in accordance with the Contract LS 1
M1508
Allow for all other specified obligation as set out in these documents and conditions of Contract LS 1
M1509
The Tenderer is to describe hereunder, insertion any relevant clause number, any other works
obligations or things that may be referred to in the conditions of Contract, Specifications
Drawings. Or Data Schedule for which no separate item has been include
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 32 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M1000 - General Items, Erection, Testing & Commissioning

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign


No. ETB ETB Currency Currency
M1600 Local Transportation
M1601 Transport of imported plant from port of arrival to Site Sum 1
M1602 Transport to Site of plant purchased within Ethiopia Sum 1
M1603 Off- loading and storing at Site of all plant to be supplied under this Contract Sum 1
M1604

The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered
in the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 33 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M2000 - Inlet Bypass & Screen & Grit Chamber
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
% of Foreign
No. ETB ETB Foreign Currency Currency

Supply complete set of the following items of plant and equipment, CIF port of Destination,
Djibouti port as specified and shown on the drawings:- (Erection and commissioning is included in
Section M1000)
M2100 Inlet Bypass
M2101 channel gate, 1300mm x 1000mm No.  2
M2102 penstock gate, 600mm x 600mm No.  2
M2103 Stainless steel adjustable flat rectangular Weir 1300 x150 x 4 mm No.  1
M2104 ultrasonic flow measurement transducer for local and remote reading, consisting of sensor, signal
convertor, local indicator digital/analog type No.  1
M2105 SF Steel pipe with puddle DN600, PN10, L =500mm No.  2
M2106 DF reducer DN600/1000, PN10 No.  2
M2107 Flanged Socket Adapter, DCI, DN1000 No. 2
M2200 Screen Chamber
M2201 channel gate, 1300mm x 800mm No.  2
M2202 Coarse screen, 1.8 x 1.3 m with 50mm openings No.  2
M2203 Drain plate 1.7x 0.8 m No.  2
M2204 Stop log with steel frame & nine 1.3 x 0.15 m panels No.  2
M2300 Grit Chamber
M2301 channel gate, 1200mm x 800mm No.  3
M2302 channel gate, 1200mm x600mm No.  3
M2303 bottom drain, conical seat plug valve, DN200 with spindle, pedestal wheel & extension rod No.  6
M2304 SF pipe with puddle DN200, PN10, L =1000mm No.  6
M2305 Plain end bend DN 200 PN 10 No.  2
M2306 Plain end tee DN 200 PN 10 No.  4
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 34 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M2000 - Inlet Bypass & Screen & Grit Chamber
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
% of Foreign
No. ETB ETB Foreign Currency Currency
M2307 Plain end steel pipe l=6m DN 200 PN 10 No.  6
M2308 4 wheeled, towed (manual and vehicular) trailer to transport screenings to disposal site, with a
suitable mechanism to attach, secure and detach a 1m3 screenings container, including all
necessary accessories
No.  2
M2309 1m3 capacity screenings container, with detachable lid, including all necessary accessories
No.  4
M2400 Parshall Flume
M2401 Ultrasonic Flow Meter for local reading at the parshall flume and remote indication, consisting of
sensor, signal converter, local indicator digital/analog type No.  1
M2500 Other
M2501 mobile Sludge type Dewatering pump, q= 7M3/hr h=10m, electric cable L=20meters, with
discharge hose L=30 meters No.  2
M2502 steel railings, steel ladders at bypass chamber, screens & grit chamber Sum 1
M2503 Pipe support with pipe clamp, foot plate, anchor bolts etc. Sum 1
M2504 Necessary pipes, fittings bolts, nuts, gaskets etc. required to complete installation Sum 1
M2505 The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered in
the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 35 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M3000 - Flow Distribution tank 01 at Grit Channel
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
Supply complete set of the following items of plant and equipment, CIF port of Destination,
Djibouti port as specified and shown on the drawings
M3100 Weirs
M3101 Stainless steel adjustable flat rectangular Weir 700 x150 x 4 mm No.  3
M3102 Chaquer plate 1.5 x 0.7 m No.  3
M3200 Effluent
M3201 DF Steel pipe with puddle DN400, PN10, L =500mm No.  5
M3202 Flanged bell mouth DN400, PN10 No.  4
M3203 Blank flange DN400, PN10 No.  1
M3204 DF steel bend DN 400 PN 10 No.  8
M3205 DF Steel pipe DN400, PN10, L =1000mm No.  8
M3206 DF Steel pipe DN400, PN10, L =2000mm No.  4
M3207 gate valve, DN 400 PN 10, with wheel & extension rod No.  3
M3208 butterfly valve, DN 500 PN 10, with wheel & extension rod No.  1
M3209 DF dismantling piece, DN400 PN10 No.  3
M3210 DF reducer, DN400/500 PN10 No.  1
M3211 DF reducer, DN500/1000 PN10 No.  1
M3212 DF reducer, DN400/800 PN10 No.  3
M3213 Flanged Socket Adapter, DCI, DN800 No.  3
M3214 Flanged Socket Adapter, DCI, DN1000 No.  1
M3300 Drain
M3301 DF Steel pipe with puddle DN400, PN10, L =500mm No.  1
M3302 Flanged bell mouth DN400, PN10 No.  1
M3303 DF steel bend DN 400 PN 10 No.  2
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
08/02/2020 BOQ 36 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki I Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M3000 - Flow Distribution tank 01 at Grit Channel
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
M3304 DF Steel pipe DN400, PN10, L =1000mm No.  2
M3305 DF Steel pipe DN400, PN10, L =2000mm No.  1
M3306 gate valve, DN 400 PN 10, with wheel & extension rod No.  1
M3307 DF dismantling piece, DN400 PN10 No.  1
M3308 Flanged Socket Adapter, DCI, DN400 No.  1
M3400 Other
M3401 ultrasonic flow measurement transducer for local and remote reading, consisting of sensor, No. 
signal converter, local indicator digital/analog type, at flow distribution tank 3
M3402 steel railings, at flow distribution tank Sum 1
M3403 Internal stainless steel ladder with cage L=1.4m, for flow distribution tank Sum 1
M3404 External galvanized steel ladder with cage L=4.5m, for flow distribution tank Sum 1
M3405 Pipe support with pipe clamp, foot plate, anchor bolts etc. Sum 1
M3406 Necessary pipes, fittings bolts, nuts, gaskets etc. required to complete installation Sum 1
M3407 The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge. ( this charge is to be entered in the
Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 37 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M4000 - Lifting Station 01 & Flow Distribution Tank 02
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
Supply and Install complete set of the following items of plant and equipment, CIF port of
Destination, Djibouti port as specified and shown on the drawings:-
M4100 Lifting Station01
M4101 Archimedean type lift pump, Q=286l/s H=7.5m, with three helical screws, D=1.1~1.2m , L=
13.08m , with electric motor, three phase, squirrel cage, induction type, 380v, 50hz , reduction
gear box & all accessories required for a complete installation
No.  3
M4102 DF Steel pipe with puddle DN700, PN10, L =1000mm No.  1
M4103 DF Steel pipe with puddle DN500, PN10, L =1000mm No.  1
M4104 Flanged bell mouth DN700, PN10 No.  1
M4105 Flanged bell mouth DN500, PN10 No.  1
M4106 DF reducer, DN700/1000 PN10 No. 1
M4107 DF reducer, DN500/1000 PN10 No. 1
M4108 butterfly valve, DN 500 PN 10, with wheel & extension rod No.  1
M4109 Flanged Socket Adapter, DCI, DN1000 No. 2
M4200 Flow Distribution Tank02
M4201 DF Steel pipe with puddle DN400, PN10, L =500mm No.  3
M4202 Flanged bell mouth DN400, PN10 No.  3
M4203 Blank flange DN400, PN10 No.  1
M4204 DF steel bend DN 400 PN 10 No.  4
M4205 DF Steel pipe DN400, PN10, L =5000mm No.  2
M4206 DF Steel pipe DN400, PN10, L =2000mm No.  4
M4207 gate valve, DN 400 PN 10, with wheel & extension rod No.  2
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 38 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M4000 - Lifting Station 01 & Flow Distribution Tank 02
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
M4208 DF dismantling piece, DN400 PN10 No.  2
M4209 DF Steel reducer DN400/800, PN10 No.  2
M4210 DF Steel pipe DN800, PN10, L =1000mm No.  2
M4211 Flanged Socket Adapter, DCI, DN800 No.  2
M4212 Stainless steel adjustable flat rectangular Weir 540 x150 x 4 mm No.  2
M4213 Chaquer plate 0.90 x 0.8 m No.  3
M4300 drainage system
M4301 SF Steel pipe with puddle DN150, PN10, L =500mm No.  2
M4302 DF Steel pipe with puddle DN150, PN10, L =500mm No.  5
M4303 DF Steel pipe DN150, PN10, L =3450mm No.  1
M4304 DF steel bend DN 150 PN 10 No.  5
M4305 DF Steel pipe DN150, PN10, L =6000mm No.  3
M4306 DF Steel pipe DN150, PN10, L =1200mm No.  1
M4307 DF Steel pipe DN150, PN10, L =2450mm No.  1
M4308 DF Steel pipe DN150, PN10, L =750mm with a plain end DN150 branch No.  3
M4309 SF Steel pipe DN150, PN10, L =750mm with a plain end DN150 branch No.  1
M4310 DF Steel pipe DN150, PN10, L =1200mm with a plain end DN150 branch No.  1
M4311 DF steel tee DN 150 PN 10 No.  2
M4312 gate valve, DN 150 PN 10, with wheel No. 2
M4313 DF dismantling piece, DN150 PN10 No. 2
M4314 Flanged Spigot Adapter, DCI, DN150 No. 1
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 39 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M4000 - Lifting Station 01 & Flow Distribution Tank 02
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
M4500 Other
M4501 Monorail crane with fixed I beam, manual hoist with integral trolley, chain and all accessories Sum
required for complete installation, capacity 3 ton 1
M4502 ultrasonic flow measurement transducer for local and remote reading, consisting of sensor,
signal converter, local indicator digital/analog type No.  2
M4503 steel railings, steel ladders at lifting station02 Sum 1
M4504 Pipe support with pipe clamp, foot plate, anchor bolts etc. Sum 1
M4505 Necessary pipes, fittings bolts, nuts, gaskets etc. required to complete installation Sum 1
M4506 The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered
in the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 40 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M5000 - Mobile Desludging System
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
Supply and Install complete set of the following items of plant and equipment, CIF port of
Destination, Djibouti port as specified and shown on the drawings:-
M5100 Wet pit type drainage pumps
M5101 Pump, submersible, dewatering, wet pit type, stainless steel or equivalent casing, shaft and
impeller, to pump sludge from the ponds, with integral bottom strainer, DN150 PN10 discharge
flange, for operation from raft located on pond, max. pond depth =4.5meters, q= 40 l/s h= 23m
-- with 100 meter of 3x4mm2 power cables, with 50 meter of control cables, electric motor, three
phase, squirrel cage, induction type, 400v, 50hz, RPM=1500
No.  2
M5102 raft, movable around pond manually, raft components easily assembled and disassembled to
move raft from pond to pond, with fixed top structure for installation of drainage pump
underneath raft at depths varying from 0.5 to 4.5 meters and DN150 flanged connections to
discharge hose and pump outlet flange, including the following accessories installed on the raft,
1. pump lifting & lowering mechanism, 2. pump control panel (star/delta), 3. pump power cable
reel, 4. discharge hose reel, including 0.5 meter & 1meter of DN150 double flanged steel pipes
sufficient for installation of pump from 0.5 to 4.5 meters, including all accessories required to
complete the installation

No.  1
M5103 Industrial flat type, discharge hose (fire hose) DN150, flanged on both ends, L= 50 meters No.  2
M5200 Discharge side piping
M5201 DF steel bend DN 150 PN 10 No.  24
M5202 DF Steel pipe DN150, PN10, L =1000mm No.  24
M5203 DF Steel pipe DN150, PN10, L =2000mm No.  12
M5204 DF Steel pipe DN150, PN10, L =3000mm No.  12
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 41 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M5000 - Mobile Desludging System
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
M5205 gate valve, DN150 PN 10, with wheel & extension rod No.  12
M5206 DF dismantling piece, DN150 PN10 No.  12
M5207 DF Steel reducer DN150/250, PN10 No.  12
M5208 DF Steel pipe DN250, PN10, L =1000mm No.  12
M5209 Flanged Socket Adapter, DCI, DN250 No.  12
M5300 Effluent
M5301 DF Steel pipe with puddle DN400, PN10, L =500mm No.  4
M5302 Flanged bell mouth DN400, PN10 No.  4
M5303 Blank flange DN400, PN10 No.  2
M5304 DF steel bend DN 400 PN 10 No.  4
M5305 DF Steel pipe DN400, PN10, L =5000mm No.  2
M5306 DF Steel pipe DN400, PN10, L =2000mm No.  4
M5307 gate valve, DN 400 PN 10, with wheel & extension rod No.  2
M5308 DF dismantling piece, DN400 PN10 No.  2
M5309 DF Steel reducer DN400/500, PN10 No.  2
M5310 Flanged Socket Adapter, DCI, DN500 No.  2
M5400 Drainage system
M5401 SF Steel pipe with puddle DN150, PN10, L =500mm No.  1
M5402 DF steel bend DN 150 PN 10 No.  1
M5403 DF Steel pipe DN150, PN10, L =5000mm No.  1
M5404 gate valve, DN 150 PN 10, with wheel No. 1
M5405 DF dismantling piece, DN150 PN10 No. 1
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 42 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C11 MECHANICAL WORKS
M5000 - Mobile Desludging System
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
M5406 DF Steel pipe DN150, PN10, L =1200mm No.  2
M5407 Flanged Spigot Adapter, DCI, DN150 No. 1
M5500 Other
M5501 Necessary pipes, fittings, adapters, bolts, nuts, gaskets etc. required to complete installation
Sum 1
M5502 The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered
in the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 43 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M6000 - Flow Distribution Tank 03
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
Foreign % of Foreign
No. ETB ETB Currency Currency
Supply and Install complete set of the following items of plant and equipment, CIF port of
Destination, Djibouti port as specified and shown on the drawings:-
M6100 Influent
M6101 DF Steel pipe with puddle DN250, PN10, L =500mm No.  1
M6102 Flanged bell mouth DN250, PN10 No.  1
M6103 DF steel bend DN250 PN 10 No.  2
M6104 DF Steel pipe DN250, PN10, L =4000mm No.  1
M6105 DF Steel pipe DN250, PN10, L =2000mm No.  2
M6106 gate valve, DN250 PN 10, with wheel & extension rod No.  1
M6107 DF dismantling piece, DN250 PN10 No.  1
M6108 DF Steel pipe DN250, PN10, L =1000mm No.  1
M6109 Flanged Socket Adapter, DCI, DN250 No.  1
M6200 Weirs
M6201 Stainless steel adjustable flat rectangular Weir 600 x150 x 4 mm No.  2
M6202 Chaquer plate 0.8 x 0.7 m No.  2
M6300 Effluent
M6301 DF Steel pipe with puddle DN250, PN10, L =500mm No.  2
M6302 Flanged bell mouth DN250, PN10 No.  2
M6303 DF steel bend DN 4250 PN 10 No.  2
M6304 DF Steel pipe DN250, PN10, L =4000mm No.  2
M6305 DF Steel pipe DN250, PN10, L =2000mm No.  4
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 44 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M6000 - Flow Distribution Tank 03
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
Foreign % of Foreign
No. ETB ETB Currency Currency
M6306 gate valve, DN 250 PN 10, with wheel & extension rod No.  2
M6307 DF dismantling piece, DN250 PN10 No.  2
M6308 Flanged Socket Adapter, DCI, DN250 No.  2
M6400 Other
ultrasonic flow measurement transducer for local and remote reading, consisting of sensor,
M6401 signal converter, local indicator digital/analog type at FDT03
No.  2
M6402 steel railings, at FDT03 Sum 1
M6403 Internal stainless steel ladder with cage , for FDT03 Sum 1
M6404 External galvanized steel ladder with cage, for FDT03 Sum 1
Manhole cover with ventilation pipe frame & cover chromium nickel steel opening 80 x80 cm Sum
M6405
with safety lock and key 1
M6406 Ventilation pipe with dome DN 100 steel pipe with puddle No. 3
M6407 Pipe support with pipe clamp, foot plate, anchor bolts etc. Sum 1
M6408 Necessary pipes, fittings bolts, nuts, gaskets etc. required to complete installation Sum 1
The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered
M6409 in the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 45 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT
Akaki Sewage Treatment Works
BILL NO. C11 MECHANICAL WORKS
M6000 - Flow Distribution Tank 03
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
Foreign % of Foreign
No. ETB ETB Currency Currency
BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 46 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C12 ELECTRICAL WORKS
E1000 - WWTP Electrical

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


Foreign % of Foreign
No. ETB ETB Currency Curency
Supply and Install complete set of the following items of plant and equipment, CIF port of
Destination, Djibouti port as specified and shown on the drawings:-
E1100 Switchgears & Control panels

Main switchgear (SG1) within main standby diesel house including all protection, relays,
metering, controls, surge diverters, glands, contactors starter panels, etc as specified and shown
E1101 on the Employer's Drawings No. 1
E1102 automatic mains failure changeover switch (AMF) in diesel house No. 1

E1103 All as item SG1 above but synoptic panel/remote indicating panel/ (SP) within the control room No. 1

E1104 All as item SG1 above but motor control center(MC1) within LS01 including starter panels etc No. 1
E1105 All as item SG1 above, but for auxiliary distribution switchgear (AG1) in diesel house No. 1
E1106 All as item SG1 above but auxilary switch gear (AG2) within LS01 No. 1
E1107 All as item SG1 above, but for auxiliary distribution switch gear (AG5) in office & lab No. 1
E1108 All as item SG1 above, but for auxiliary distribution switch gear (AG6) in store & workshop No. 1

E1109 All as item SG1 above, but for auxiliary distribution switch gear (AG7) in operator's dwelling No. 1
E1110 All as item SG1 above, but for auxiliary distribution switch gear (AG8) in guard house No. 1
All as item SG1 above, but for auxiliary distribution switch gear (AG9) for compound lighting in
E1111 ______ No. 1
All as item SG1 above, but for weather proof distribution switch gear(AG10) at the Anaerobic
E1112 Ponds No. 3
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 47 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C12 ELECTRICAL WORKS
E1000 - WWTP Electrical

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


Foreign % of Foreign
No. ETB ETB Currency Curency
E1200 Power cables
E1201 XLPE/PVC/SWA/PSV cable between EEPCO meter and AMF Sum 1
E1202 XLPE/PVC/SWA/PSV cable between diesel plant control panel and AMF Sum 1
E1203 XLPE/PVC/SWA/PSV cable between AMF and SG1 Sum 1
E1204 PVCSWAPVC cable between SG1and SP Sum 1
E1205 PVCSWAPVC cable between SG1 and MC1 Sum 1
E1206 PVCSWAPVC cable between MC1 and archimedes/sump pump motor terminals Sum 1
E1207 PVC/SWA/PSV cable between SG1 and AG1 Sum 1
E1208 PVC/SWA/PSV cable between MC1 and AG2 Sum 1
E1209 PVC/SWA/PSV cable between SG1 and AG5 Sum 1
E1210 PVC/SWA/PSV cable between SG1 and AG6 Sum 1
E1211 PVC/SWA/PSV cable between SG1 and AG7 Sum 1
E1212 PVC/SWA/PSV cable between SG1 and AG8 Sum 1
E1213 PVC/SWA/PSV cable between SG1 and AG9 Sum 1
E1214 PVCSWAPVC cable between AG9 and external flood lights Sum 1
E1215 PVCSWAPVC cable between AG10 and weather proof termination boxes on the AP Sum 1
All other power cable requirement not covered by the above items and required to complete the Sum 1
E1216 specified works
E1300 Control Cables
E1301 Control cabling from MC1 to weatherproof termination box on FDT01 Sum 1
Control cabling and wiring between the weather proof termination box and the level control Sum 1
E1302 probes/sensors in FDT01
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 48 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C12 ELECTRICAL WORKS
E1000 - WWTP Electrical

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


Foreign % of Foreign
No. ETB ETB Currency Curency
E1303 Control cabling from MC1 to Archimedes/sump pump motors Sum 1
E1304 Control cabling from MC1 to SP Sum 1
E1305 Control cabling from SP to weatherproof termination box on bypass chamber Sum 1
Control cabling and wiring between the weather proof termination box and the flow measurement Sum 1
E1306 transducer in bypass chamber
Sum 1
E1307 Control cabling from AG10 to weatherproof termination boxes on the Anaerobic Ponds
All other control protection, monitoring cabling and wiring required within the WWTP compound to Sum 1
E1308 meet the specified requirement
E1400 Controls
E1401 Weather proof termination box (cabinet) for fixing to FDT01 No. 1
E1402 Level control equipment and probes complete as specified for FDT01 Sum 1
E1403 Weather proof termination box (cabinet) for fixing to bypass chamber No. 1
E1404 Level control equipment and probes complete as specified for bypass chamber Sum 1
E1405 Weather proof termination box (cabinet) for fixing to Anaerobic Ponds No. 12
all other controls and protection requirements within the treatment plant compound to meet the Sum 1
E1406 specified requirement
E1500 Building Electrical
all, lighting, power, accessories, switches, and all items necessary and required for Complete Sum 1
E1501 electrical installation within standby generator house
all, lighting, power, accessories, switches, and all items necessary and required for Complete Sum 1
E1502 electrical installation within LS01
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

08/02/2020 BOQ 49 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C12 ELECTRICAL WORKS
E1000 - WWTP Electrical

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


Foreign % of Foreign
No. ETB ETB Currency Curency
E1600 General Electrical Requirements at treatment plant
Road lighting installation One steel column 7.5meter long complete with 70watt HPS light fittings
E1601 and lamps No. 36
Flood lighting installation One steel column 9.5meter long complete with Two 500watt flood light
E1602 fittings and lamps No. 4
E1603 Photo-electrical cells for flood light and road light control Sum 1
Earthing materials, including all inspection chambers, rods, tape, bonding straps etc as necessary
E1604 for the earthing requirements throughout the compound Sum 1
E1605 Bare copper earth wire to run in parallel with power cables and to connect earthing rod Sum 1
Cable tray, cable trunking, cable supports etc as required throughout the compound and facility Sum 1
E1606 building
E1700 Other Sum 1
E1701 chaquer plate Sum 1
E1702 The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered in
the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 50 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki I Sewage Treatment Works


BILL NO. C12 ELECTRICAL WORKS
E2000 - Standby Power
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT Foreign % of Foreign
No. ETB ETB Currency Currency
Supply and Install complete set of the following items of plant and equipment, CIF port of
Destination, Djibouti port as specified and shown on the drawings:-
E2100 AKAKI WWTP

diesel generator set, continuous rating, as per the technical specification, engine & alternator
E2101 pre-installed on a common rigid frame, switchgear, day tank incorporated into the frame,
exhaust piping system and all accessories required for installation at WWTP, alternator: 250
KVA, 3 phase, 400 V, 1500 RPM No. 1
Sum
E2102 Bridge (traveling) crane with fixed I beam, manual hoist with integral trolley capacity 3 ton,
chain & all accessories required to fix the crane 1

E2103 Supply and connect up complete semi-rotary hand pump including supports, drip tray, hose
connection and the like as required No. 1
E2200 Other
E2201 Chaquer plate Sum 1

The Tenderer is to describe hereunder, inserting any relevant clause number, any other works
E2202 obligations or things that may be referred to in the Conditions of Contract, Specifications,
Drawings or Data Schedule for which no separate item has been included in the schedule of
prices and for which he desires to enter a separate charge ( this charge is to be entered
in the Amount Column) If no charge is entered hereunder, rates and amounts elsewhere in the
Schedule of prices shall be deemed to cover all expenses for such works, obligations or things.

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

08/02/2020 BOQ 51 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

SUMMARY OF BILL No. C13


CONSTRUCTION OF AUXILIARY BUILDINGS & SITE WORKS
Amount
BILL NO. DESCRIPTION ETB
BILL NO.C13 CONSTRUCTION OF AUXILIARY BUILDINGS & SITE WORKS
13A:- Administrative Building And Laboratory
13B:- Workshop And Store
13C:- Operator Dwelling House
13D:- Guard House
13E:- Toilets
13F:- Shower Rooms
13G:- Control Room & Generator Houses
13H:- Site Works

BILL TOTAL CARRIED TO SUMMARY

52 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
A. SUB-STRUCTURES
1 Earthworks
1.1 Site clearing to a depth of about 20 cm m2 260.00
1.2 Excavation in common soil for foundation & ground to a depth not
exceeding 1.50 meters m3 144.00
1.3 Excavation in common soil for foundation to a depth not exceeding
3.00 meters m3 144.00
1.4 Excavation in common soil for trench along the outside perimeter to a
depth not exceeding 1.50 meters m3 24.60
1.5 Cart away excavated material to a distance not exceeding 1 km and
placing as flood protection embankment m3 364.60
1.6 Selected excavated fill material and compacted layer by layer m3
50.00
1.7 Selected borrowed fill material and compacted layer by layer for m3
570.03
footing, trench and bulk fills
1.8 25 cm thick hard core filling and blinded with basaltic or equivalent m2 133.20
material
1.9 Stone Masonry
1.10 50cm wide stone masonry wall with dressed, impermeable, non- m3 15.90
weathered and non-fractured stone external surface left for pointing
1.11 50cm wide stone masonry wall with dressed, impermeable, non- m3 33.90
weathered and non-fractured stone below the natural ground level
(depth about 1.5m)

1.12 One meter width semi dressed stone pavement around building and m2 53.20
jointed with cement mortar mix. 1:3 and including earthworks & bedding
materials
1.13 Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch m2 109.80
around the building size 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks.

2 Concrete Work
2.1 5 cm thick lean concrete C-5 under footing & grade beams m2 69.36
2.2 Ditto, but under ground floor slab m2 133.20
2.3 C-25 concrete in footings m3
13.50
2.4 Ditto, but in foundation columns m3 3.12
2.5 Reinforced concrete in ground floor slab 15 cm thick with C-20 m2 133.20
concrete class
2.6 Reinforced concrete in grade beams with C-25 concrete class m3 7.81
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 53 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
3 Sawn zigba or equivqlnet form work
3.1 To sides of footings m2 44.00
3.2 To sides of foundation columns m2 79.20
3.3 To sides of grade beams m2
70.32
4 Mild steel rod reinforcement, cutting, bending, tying & placing in
position
4.1 Diam. 8mm deformed kg 474.32
4.2 Diam. 12mm deformed kg 113.66
4.3 Diam. 16mm deformed kg 1361
B. SUPER-STRUCTURES
5 Concrete Work IN CONCRETE C-25
5.1 In elevation columns m3 4.55
5.2 In suspended beams m3
16.10
5.3 In suspended staircases m3 1.73
5.4 In lintels m3
2.35
5.5 In 15 cm thick floor slab m2 228.80
6 Sawn zigba or equivqlnet form work
6.1 In elevation columns m2 135.36
6.2 In suspended beams m2 172.20
6.3 In suspended staircases m2
11.64
6.4 In lintels m2 38.52
6.5 In floor slab m2
157.16
7 Mild steel rod reinforcement, cutting, bending, tying & placing in
position
7.1 Diam. 8mm deformed kg 2172.30
7.2 Diam. 10mm deformed kg 74.00
7.3 Diam.12mm deformed kg 87.50
7.4 Diam. 16mm deformed kg 3224.70
8 Block Work
8.1 20 cm thick hollow concrete block walls, Class B m2 274.55
8.2 15 cm thick hollow concrete walls to internal partitions, Class B m2 255.75
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 54 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
9 Roofing work
9.1
Roof cover in EGA-400 0.4mm thick including roof ridge cover fixed to
steel purlins with dome shaped screws. Roof measured in horizontal
projections m2 194
9.2
Gauge 28 galvanized iron sheet gutter girth 33 cm welded at joints and
2% slope is provided towards down pipe. Price shall include three
coats of oil paint ml 33
9.3 Ditto, but 5x10 cm down pipe fixed to wall with metal straps (1m c/c) ml 36
10 Carpentry and Joinery
10.1 Soffit nailed to support 8 mm chip wood ceiling on 4x5 batten m2 133.20
10.2 Flush kerrerro (or equivalent) wooden internal doors size 80x210 pcs 13.00
10.3 10x4cm wooden zigba or equivqlnet 2x3+ 0.3m,to edge chamfered and m 6.30
nailed to the metal plates by screws
Steel Structures
11 Trusses & purlins in structural RHS
11.1 Size 60x60x2.5 kg 711.18
11.2 Size 50x50x2.5 kg 172.80
11.3 Purlin Size 80x60x3 kg 1462.98
11.4 RHS hand rail, Size 25x25x2.0 kg 130.56
11.5 Angle ties size 80x80x4 L=60 kg 30.00
11.6 Plates 6 mm thick SIZE= 200x200mm kg 150.00
11.7 Anchor bolts diam. 12 L=50 cm kg 32.00
Metal Work for External Windows and Doors with LTZ black steel
11.8 Plates 6 mm 38mm
profile frame thick SIZE=25x25mm, for hand
wide & 1.5mm thick rail
all according to the drawing kg 0:00
with all grills, anti-rust and other paintings and all handle and lock
accessories.
12 Windows
1.0 Size 100x120cm pcs 17.00
2.0 Size 140x120 pcs 2.00
3.0 Size160x120 (LOUVERD WINDOW) pcs 4.00
13 Doors
13.1 Size 160x210 main gate pcs 1.00
13.2 Size 160x210 sliding door with bottom and top rollers, stoppers & all
accessories pcs 1.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 55 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
14 Plastering & Pointing Work
14.1 Two coats of plastering with cement mortar mix. 1:3 to surface of
14.2 HCB & concrete internal wall surface m2 530.30
14.3 HCB & concrete external wall surface m2
511.50
14.4 Fine coats cement plaster to surface of
14.5 HCB & concrete internal wall surface m2 530.30
14.6 HCB & concrete external wall surface m2
511.50
15 Floor & Wall Finishing
15.1 5cm thick cement screed for the floors m2 362.00
15.2 Recessed pointing to external masonry surface above the ground m2
19.70
16 Plastic tile flooring & skirting
16.1 Plastic tile flooring m2 166.34
16.2 Plastic skirting ml 183.68
17 Terrazzo tile flooring & skirting
17.1 Terrazzo tile flooring, 2cm thick m2 61.06
17.2 Terrazzo skirting size 10/2 cm ml 75.20
18 Ceramic wall tile
18.1 6 mm thick white ceramic wall tile m2 32.65
19 Window cill
19.1 Size 27/3 terrazzo window cill m2 7.07
20 Steps
20.1 3 cm thick harar marble threads size 33x100 cm m2 9.63
20.2 3 cm thick harar marble risers size 15x100 cm m2
2.70
Painting
21 Plastic emulsion paint
21.1 Plastered vertical wall surface m2 1041.80
21.2 Chip wood ceiling m2
133.20
21.3 Concrete ceiling m2 133.20
21.4 Belly's of stair case m2
9.44
22 Glazing
22.1 4 mm thick clear glass m2 16:48
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 56 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
Sanitary Installation

Supply and construct PN16 GS, DCI or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts, bedding and
earthworks for a depth not less than 800mm.
23 Galvanized Steel Pipes with all fittings and accessories
23.1 Diam. 5 mm ml 18.00
23.2 Diam. 18.75 mm ml 72.00

Supply and construct PN4 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
24 PVC pipe for sewage drainage with all fitting and accessories
24.1 Diam. 150 mm ml 30.00
24.2 Diam. 100 mm ml 12.00
24.3 Diam. 50 mm ml 6.00
25 Gate valves made of bronze with all accessories (PN 16) and approved
by the Engineer
25.1 Diam. 5 mm pcs 2.00
25.2 Diam. 18.75 mm pcs 5.00
25.3 White
White Vitreous WC with
Vitreous hand lowbasin
wash flushwith
including all and
pedistal accessorriees
all accessories for pcs 2.00
25.4 cold water size 500x405 pcs 2.00
25.5 Enameled steel grated floor drain diam. 50 mm pcs 2.00
25.6 50x40cm wide approved crystal glass mirror pcs 2.00
25.7 pcs 1.00

Provide and construct 10m3 approved plastic or fiber-glass elevated


water tank on the office roof. The cost includes the reinforced concrete
seat, necessary fittings and pipes from the ground to the tank.
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 57 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13A- CONSTRUCTION OF WWTP ADMINISTRATION BUILDING CIVIL WORKS
ITEM DESCRIPTION UNIT QNTY RATE AMOUNT
No. ETB ETB
Electrical Installation
26
Supply and install sub-distribution board SDB for flush mounted
complete with bars and other accessories consisting of
26.1 Flush mounted Dist. Board with lockable door, earthing lead,
connectors and all accessories
2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
1pcs 32amp ABC 1-phase pcs 2.00
Light fitting with lumps (specified) type or equivalent
26.2 Philips TMS 012/140 with 1x40w fluorescent lamp pcs 28.00
26.3 Philips TMS 065/118 with 2x40w fluorescent lamp pcs 3.00
26.4 Philips bulbs type E=27, 40 W for toilet rooms pcs 2.00
26.5 pcs 28.00
Light point fed through PVC insulated conductor of 2x2,5mm2 in
conduit of dia.13mm under surface including junction boxes with cover,
Legrand switches, etc. as shown in the drawing
26.6 pcs 18.00
Flush mounted Legrand socket outlets of 16 amp/220v with earthing
contact fed through conductors of 3x2,5mm2 in conduit of min.
dia.16mm in/under surface including junction box with covers and
installing screw caps etc
26.7 Flush mounted telephone socket fed through tele wire in conduit of dia. pcs 12.00
13mm and cups
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

BOQ Page 58 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13B- CONSTRUCTION OF WORKSHOP AND STORE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A. SUB-STRUCTURES
1.0 Earth work
1.1 Site clearing to a depth of about 20 cm m2 290.00
1.2 Excavation in common soil for footing foundation & ground to a depth m3 57.38
not exceeding 1.5m
1.3 Excavation in common soil for footing foundation to a depth exceeding m3 57.38
1.5m but notin3m
Excavation common soil for masonry trench to a depth not exceeding
1.4 1.5m m3 47.00
1.5 Cart away excavated material to a distance not exceeding 1km and m3
219.76
place as embankment protection
1.6 Selected excavated fill material and compacted layer by layer m3 50.00
1.7 Selected borrowed fill material and compacted layer by layer m3
129.02
1.8 25 cm thick hard core filling and blinded with basaltic or equivalent m2 135.90
material
2.0 Stone Masonry
2.1 50cm width stone masonry wall , impermeable, non-weathered and m3 40.40
non-fractured stone buried inside the earth
2.2 50cm width stone masonry wall , impermeable, non-weathered and m3 13.50
non-fractured stone external surface left for pointing
2.3 m2 57.22
0,80 m meter wide semi dressed stone pavement around building and
jointed with cement mortar mix. 1:3 including earthwork and beddig
2.4 Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch m2 137.50
around the building size: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks.

3.0 Concrete Work


3.1 5 cm thick lean concrete C-5 under footing & grade beams m2 39.82
3.2 Ditto, but under ground floor slab m2
135.90
3.3 C-25 concrete in footings m3 4.30
3.4 Ditto, but in foundation columns m3
3.80
3.5 Reinforced concrete in ground floor slab 10 cm thick with C-20 concrete m2 135.90
class
3.6 Reinforced concrete in grade beams with C-25 concrete class m3 4.82
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 59 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13B- CONSTRUCTION OF WORKSHOP AND STORE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
4.0 Sawn zigba or equivqlnet form work
4.1 To sides of foundation m2 17.50
4.2 To sides of foundation columns m2
63.50
4.3 To sides of grade beams m2 48.20
5.0 Mild steel rod reinforcement, cutting, bending, tying & placing in
position.
5.1 Diam. 8mm deformed kg 480.00
5.2 Diam.12mm deformed kg 210.00
5.3 Diam. 16mm deformed kg 670
B. SUPER-STRUCTURES
6.0 Concrete Work IN CONCRETE C-25
6.1 In elevation columns m3 1.80
6.2 In suspended beams & lintels m3 4.80
7.0 Sawn zigba or equivqlnet form work
7.1 In elevation columns m2 54.00
7.2 In suspended beams m2 48.00
8.0 Mild steel rod reinforcement, cutting, bending, tying & placing in
position.
8.1 Diam. 8mm deformed kg 250.00
8.2 Diam. 16mm deformed kg 820.00
9.0 Block Work
9.1 20 cm thick hollow concrete block walls m2 500.00
10.0 Roofing work
10.1 m2 175.00
Roof cover in EGA-300 0.3 mm thick including roof ridge cover fixed to
steel purlins with dome shaped screws. Roof measured in horizontal
projections
10.2 Gauge 28 galvanized iron sheet gutter girth 33 cm welded at joints and ml 28.00
2% slope is provided towards down pipe. Price shall include three coats
of oil paint
10.3 Ditto, but 5x10 cm down pipe fixed to wall with metal straps ml 24.00
11.0 Carpentry and Joinery
11.1 Soffit nailed to support 8 mm chip wood ceiling m2 140.00
11.2 Flush kerrerro (or equivalent) wooden internal doors size 80x210 type pcs 2.00
D1
11.3 25x2,5 fascia board lm 70.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 60 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13B- CONSTRUCTION OF WORKSHOP AND STORE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Steel Structures
12.0 Trusses & purlins in structural RHS
1.0 Size 50x50x2,5 kg 299.27
2.0 Size 60x60x2,5 kg 439.97
3.0 Purlin Size 80x60x2.5 kg 936.91
4.0 Angle ties size 80x80x4 L=40 & 30 mm kg 20.00
5.0 Plates 6 mm thick kg 45.00

Metal Work for External Windows and Doors with LTZ black steel
profile frame 38mm wide & 1.5mm thick all according to the drawing
with all grills, anti-rust and other paintings and all handle and lock
accessories.
13.0 Windows
13.1 Size type W1 size 140x60 pcs 8.00
13.2 Size type W2 size 140x180 pcs 1.00
14.0 Doors
14.1 Size type D2 size 150x210 pcs 1.00
Size type D3 size 355x210 (sliding door with bottom & top rolling guide, pcs 1
14.2 stopper and all other accessories)
Plastering & Pointing Work
15.0 Pointing
15.1 Recessed pointing to external masonry surface above the ground m2 24.40
16.0
Two coats of plastering with cement mortar mix. 1:3 to surface of
16.1 HCB & concrete internal wall surface m2 250.00
16.2 HCB & concrete external wall surface m2
250.00
17.0 Fine coats cement plaster to surface of:-
17.1 HCB & concrete internal wall surface m2 250.00
17.2 HCB & concrete external wall surface m2
250.00
18.0 Terrazzo tile flooring & skirting
18.1 Terrazzo tile flooring m2 140.37
18.2 Terrazzo skirting size 10/2 cm ml 82.00
19.0 Window cill
19.1 Size 27/3 terrazzo window cill ml 20.20
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 61 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13B- CONSTRUCTION OF WORKSHOP AND STORE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Painting
20.0 Plastic emulsion paint
20.1 Plastered vertical wall surface m2 500.00
20.2 Chip wood ceiling m2
140.37
21.0 Glazing
21.1 4 mm thick m2 22.00
Electrical Installation
22.0 Supply and install
22.1 Distribution board DB for flush mounted
complete with bars and other accessories consisting of
2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
1pcs 32amp ABC 1-phase pcs 1.00
22.2 Philips TMS 012/140 with 1x40w fluorescent lamp pcs 7.00
22.3 Philips TMS 065/118 with 2x40w fluorescent lamp pcs 5.00
22.4 pcs 3.00
Light point fed through PVC insulated conductor of 2x2,5mm2 in conduit
of dia.13mm under surface including junction boxes with cover, Legrand
switches, etc. as shown in the drawing
22.5 pcs 7.00
Flush mounted Legrand socket outlets of 16 amp/220v with earthing
contact fed through conductors of 3x2,5mm2 in conduit of min.
dia.16mm in/under surface including junction box with covers and
installing screw caps etc
22.6 Flush mounted telephone socket fed through tele wire in conduit of dia. pcs 2.00
13mm and cups
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

BOQ Page 62 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A. SUB-STRUCTURES
1.0 Earth Work
1.1 Site clearing to a depth of about 20 cm m2 165.00
1.2 Excavation in common soil for footing foundation & ground to a depth m3 69.00
not exceeding 1.5m
1.3 Excavation in common soil for footing foundation to a depth exceeding m3 33.75
1.5m but not 3m
1.4 Excavation in common soil for masonry trench to a depth not exceeding m3 35.55
1.5m
1.5 Cart away excavated material to a distance not exceeding 1km and m3 171.30
place as embankment protection
1.6 Selected excavated fill material and compacted layer by layer m3 30.00
1.7 Selected borrowed fill material and compacted layer by layer m3
108.64
1.8 25 cm thick hard core filling and blinded with basaltic or equivalent materi m2 63.77
2.0 Stone Masonry
2.1 50cm width stone masonry wall with dressed, impermeable, non- m3 26.30
weathered and non-fractured stone below the natural ground
2.2 50cm width stone masonry wall , impermeable, non-weathered and non- m3 8.80
fractured stone external surface left for pointing
2.3 One meter width semi dressed stone pavement around building and m2 42.00
jointed with cement mortar mix. 1:3 including earthworks and bedding

2.4 Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch m2 96.80
around the building size: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks.

3.0 Concrete Work


3.1 5 cm thick lean concrete C-5 under footing & internal grade beam m2 14.40
3.2 Ditto, but under ground floor slab m2 63.77
3.3 C-25 concrete in footings m3 2.50
3.4 Ditto, but in foundation columns m3 2.03
3.5 Reinforced concrete in ground floor slab 15 cm thick with C-20 concrete m2 63.77
class
3.6 Reinforced concrete in grade beams with C-25 concrete class m3 4.58
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 63 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Sawn zigba or equivqlnet form work
3.7 To sides of footings m2 6.00
3.8 To sides of foundation columns m2 17.40
3.9 To sides of grade beams m2
42.80
4.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position
14.1 Diam. 8mm deformed kg 387.00
14.2 Diam. 12mm deformed kg 160.00
14.3 Diam. 16mm deformed kg 517.00
B. SUPER-STRUCTURES
5.0 Concrete Work IN CONCRETE C-25
5.1 In elevation columns m3 1.69
5.2 In suspended beams m3
2.56
5.4 In lintels m3 0.65
6.0 Sawn zigba or equivqlnet form work
6.1 In elevation columns m2 32.40
6.2 In suspended beams m2 31.38
6.4 In lintels m2
4.89
7.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position
7.1 Diam. 8mm deformed kg 156.00
7.4 Diam. 16mm deformed kg 661.00
8.0 Block Work
8.1 20 cm thick hollow concrete block walls m2 147.42
9.0 Roofing work
9.1 Fabrication No 9.00
Supply and and installation
installation of eucalyptus
of 5x7 cm zigba ortruss as shown
equivqlnet in purlin
wood the drawing
at
9.2 90cm spacing m 156.00
9.3 Gauge 28 galvanized iron sheet roof cover including ridge, flushing and m2 107.07
all incidental works as shown in the drawing, the area is measured
horizontally
9.4 Supply and installation of chip wood ceiling on 4x5cm battens m2 73.92
9.5 Supply and install 20cm wide fascia board including painting m 42.40
9.6 m 25.80
Gauge 28 galvanized iron sheet gutter girth 60 cm welded at joints and
2% slope is provided towards down pipe. Price shall include three coats
of oil paint
9.7 Ditto, but 10x15 cm down pipe fixed to wall with metal straps ml 21.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 64 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
10.0 Carpentry and Joinery
10.1 Flush kerrerro (or equivalent) wooden door type D1 size 100x210 cm pcs 1.00
10.2 Flush kerrerro (or equivalent) wooden door type D2 size 80x210 cm pcs 5.00

Metal Work for External Windows and Doors with LTZ black steel profile
frame 38mm wide & 1.5mm thick all according to the drawing with all
grills, anti-rust and other paintings and all handle and lock accessories.
11.0 Windows
11.1 Type D1 size 180x120cm pcs 2.00
11.2 Type D2 size 140x120cm pcs 2.00
11.3 Type D3 size 50x50 cm pcs 1.00
Plastering & Pointing Work
12.0 Pointing
1 Recessed pointing to external masonry surface above the ground m2 15.20
13.0 Two coats of plastering with cement mortar mix. 1:3 to surface of
13.1 HCB & concrete internal and external wall surface m2 147.42
14.0 Fine coats cement plaster to surface of
14.1 HCB & concrete internal and external wall surface m2 147.42
15.0 Glazing
15.1 4mm thick m2 7.70
16.0 Floor & Wall Finishing
16.1 5cm thick cement screed for the floors m2 63.77
16.2 Plastic tile flooring m2 52.00
16.3 Plastic skirting ml 50.00
17.0 Terrazzo tile flooring & skirting
17.1 Terrazzo tile flooring m2 11.76
17.2 Terrazzo skirting size 10/2 cm ml 9.30
18.0 Ceramic wall tile
18.1 6 mm thick white ceramic wall tile m2 17.00
19.0 Window cill
19.1 Size 27/3 terrazzo window cill m2 1.84
Painting
20.0 Plastic emulsion paint
20.1 Plastered vertical wall surface m2 147.42
20.2 Chip wood ceiling m2
73.92
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 65 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Sanitary Installation

Supply and construct PN16 GS, DCI or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts, bedding and earthworks
for a depth not less than 800mm.
21.0 Galvanized Steel Pipes
21.1 Diam. 5 mm ml 12.00
21.2 Diam. 18.75 mm ml 36.00

Supply and construct PN4 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
22.0 PVC pipe for sewage drainage
22.1 Diam. 150 mm ml 30.00
22.2 Diam. 100 mm ml 6.00
22.3 Diam. 50 mm ml 12
23.0 Gate valves made of bronze & approved by the Engineer
23.1 Diam. 5 mm pcs 4.00
23.2 Diam. 18.75 mm pcs 2.00
23.3 White Vitreous WC with low flush including all accessories pcs 1.00
23.4 White Vitreous hand wash basin with pedistal for cold water size 500x40 pcs 1.00
23.5 White plated metallic shower plate 0.8x0.8m with towel hanger, soap and pcs 1.00
23.6 Enameled steel grated floor drain diam. 50 mm pcs 2.00
23.7 50x40cm wide approved crystal glass mirror pcs 1.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 66 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
24.0 Electrical Installation
Supply and install sub-distribution board SDB for flush mounted
complete with bars and other accessories consisting of
24.1 2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
1pcs 32amp ABC 1-phase pcs 1.00
24.2 Light fitting with lumps (specified) type or equivalent
24.3 Philips TMS 012/140 with 1x40w fluorescent lamp pcs 3.00
24.4 Philips TMS 065/118 with 1x20w fluorescent lamp pcs 2.00
24.5 Philips bulbs type E=27, 40 W for toilet rooms pcs 1.00
24.6 pcs 2.00
Light point fed through PVC insulated conductor of 2x2,5mm2 in conduit
of dia.13mm under surface including junction boxes with cover, switches
2 way etc.
24.7 pcs 7.00

Flush mounted socket outlets of 16 amp/220v with earthing contact fed


through conductors of 3x2,5mm2 in conduit of min. dia.16mm in/under
surface including junction box with covers and installing screw caps etc
24.8 Flush mounted telephone socket fed through tele wire in conduit of dia. pcs 2.00
13mm
Service Quarter
25.0 Earth Work
25.1 Site clearing to a depth of about 20 cm m2 28.42
25.2 Excavation in common soil for footing foundation & ground slab to a m3 29.75
depth not exceeding 1.5m
25.3 Excavation in common soil for footing foundation to a depth exceeding m3 20.25
1.5m but not 3m
25.4 Excavation in common soil for masonry trench to a depth not exceeding m3 17.20
1.5m
25.5 Cart away excavated material to a distance not exceeding 1km and m3 67.88
place as embankment protection
25.6 Selected excavated fill material and compacted layer by layer m3 5.00
25.7 Selected borrowed fill material and compacted layer by layer m3
113.65
25.8 25 cm thick hard core filling and blinded with basaltic or equivalent m2 14.68
material
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 67 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
26.0 Stone Masonry
26.1 50cm width stone masonry wall , impermeable, non-weathered and non- m3 13.81
fractured stone buried inside the earth
26.2 50cm width stone masonry wall , impermeable, non-weathered and non- m3 4.60
fractured stone external surface left for pointing
26.3 One meter width semi dressed stone pavement around building and m2 24.42
jointed with cement mortar mix. 1:3 including earthworks and bedding

26.4 Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch m2 30.42
around the building size: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks.

27.0 Concrete Work


27.1 5 cm thick lean concrete C-5 under footing m2 6.80
27.2 Ditto, but under ground floor slab m2 14.68
27.3 C-25 concrete in footings m3 1.50
27.4 Ditto, but in foundation columns m3 0.78
27.5 Reinforced concrete in ground floor slab 15 cm thick with C-20 concrete m2 14.68
class
27.6 Reinforced concrete in grade beams with C-25 concrete class m3 0.87
28.0 Sawn zigba or equivqlnet form work
28.1 To sides of footings m2 7.56
28.2 To sides of foundation columns m2 8.70
28.3 To sides of grade beams m2
10.84
29.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position
29.1 Diam. 6mm deformed kg 24.58
29.2 Diam. 8mm deformed kg 62.51
29.3 Diam. 10mm deformed kg 66.19
29.4 Diam. 12mm deformed kg 132.56

B. SUPER-STRUCTURES
30.0 Concrete Work IN CONCRETE C-25
30.1 In elevation columns m3 0.65
30.2 In suspended beams m3
0.87
30.4 In lintels m3 0.18
30.5 In 15 cm thick floor slab m2
14.68
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 68 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
31.0 Sawn zigba or equivqlnet form work
31.1 In elevation columns m2 8.70
31.2 In suspended beams m2 10.82
31.3 In lintels m2
3.65
32.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position
32.1 Diam. 6mm deformed kg 26.67
32.2 Diam. 12mm deformed kg 167.00
33.0 Block Work
33.1 20 cm thick hollow concrete block walls m2 55.41
34.0 Roofing work
34.1 No 7.00
Fabrication and installation of eucalyptus truss as shown in the drawing
Supply and installation of 5x7 cm zigba or equivqlnet wood purlin at
34.2 90cm spacing m 40.30
34.3 m2 30.23
Gauge 28 galvanized iron sheet roof cover including ridge, flushing and
all incidental works as shown in the drawing, the area is measured
horizontally
34.4 Supply and installation of chip wood ceiling on 4x5cm battens m2 14.68
34.5 m 8.06
Gauge 28 galvanized iron sheet gutter girth 60 cm welded at joints and
2% slope is provided towards down pipe. Price shall include three coats
of oil paint
34.6 Ditto, but 10x15 cm down pipe fixed to wall with metal straps ml 5.70
35.0 Carpentry and Joinery
35.1 Flush kerrerro (or equivalent) wooden door size 80x210 cm pcs 3.00
36.0

Metal Work for External Windows and Doors with LTZ black steel profile
frame 38mm wide & 1.5mm thick all according to the drawing with all
grills, anti-rust and other paintings and all handle and lock accessories.
36.1 Type D1 size 100x120cm pcs 2.00
36.2 Type D3 size 50x50 cm pcs 1.00
Plastering & Pointing Work
37.0 Pointing
37.1 Recessed pointing to external masonry surface above the ground m2 8.20
38.0
Two coats of plastering with cement mortar mix. 1:3 to surface of
38.1 HCB & concrete internal and external wall surface m2 43.34
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 69 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
39.0 Fine coats cement plaster to surface of
39.1 HCB & concrete internal and external wall surface m2 43.34
40.0 Glazing
40.1 4mm thick m2 2.65
Painting
41.0 Plastic emulsion paint
41.1 Plastered vertical wall surface m2 43.34
41.2 Chip wood ceiling m2
14.68
Sanitary Installation

Supply and construct PN16 GS, DCI or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts and earthworks for a
depth not less than 800mm.
42.0 Galvanized Steel Pipes
42.1 Diam. 5 mm ml 18.00
42.2 Diam. 18.75 mm ml 24.00

Supply and construct PN4 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
43.0 PVC pipe for sewage drainage
43.1 Diam. 150 mm ml 12.00
43.2 Diam. 100 mm ml 12.00
43.3 Diam. 50 mm ml 6.00
44.0 Gate valves made of bronze approved by the Engineer
44.1 Diam. 5 mm pcs 3.00
44.2 Diam. 18.75 mm pcs 4.00
44.3 White Vitreous WC with low flush with all accessories pcs 1.00
44.4 White Vitreous hand wash basin with pedistal for cold water size pcs 1.00
500x405
44.5 White plated metallic shower plate 0.8x0.8m with approved shower pcs 1.00
head
44.6 Enameled steel grated floor drain diam. 50 mm pcs 1.00
44.7 50x40cm wide approved crystaal glass mirror pcs 1.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 70 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13C- CONSTRUCTION OF OPERATORS DWELLING CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Electrical Installation
45.0 Supply and install sub-distribution board SDB for flush mounted
complete with bars and other accessories consisting of
2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
45.1 1pcs
Light 32amp
point fedABC 1-phase
through PVC insulated conductor of 2x2,5mm2 in conduit pcs 1.00
45.2 of dia.13mm under surface including junction boxes with cover, Legrand pcs 3.00
switches 2 ways, etc. as shown in the drawing
45.3 pcs 3.00
Flush mounted Legrand socket outlets of 16 amp/220v with earthing
contact fed through conductors of 3x2,5mm2 in conduit of min.
dia.16mm in/under surface including junction box with covers and
installing screw caps etc
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

BOQ Page 71 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13D- CONSTRUCTION OF GUARD HOUSE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A : SUB - STRUCTURE
1.0 Earth Work
1.1 Site clearing to a depth of about 20 cm m2 25.00
1.2 Excavation in common soil for footing foundation & ground salb to a
depth not exceeding 1.5m m3 18.00
1.3 Excavation in common soil for footing foundation to a depth exceeding
1.5m but not 3m m3 13.50
1.4 Excavation in common soil for masonry trench to a depth not exceeding
1.5m m3 18.30
1.5 Cart away excavated material to a distance not exceeding 1km and
place as embankment protection m3 50.80
1.6 Selected excavated fill material and compacted every 20cm layer to
standard proctor density. m3 4.00
1.7 Selected borrowed fill material and compacted every 20cm layer to
standard proctor density m3 39.11
1.8 25 cm thick hard core filling and blinded with basaltic or equvalent
material m2 9.30
2.0 Stone Masonry
2.1 50cm width stone masonry wall , impermeable, non-weathered and
non-frractured stone burried inside the earth m3 5.49
2.2 50cm width stone masonry wall , impermeable, non-weathered and
non-frractured stone external surface left for pointing m3 1.22
2.3 One meter width semi dressed stone pavement around building and
jointed with cement mortar mix. 1:3 including earthworks and bedding
m2 17.80
2.4 Semi-dressed stone lined and pointed (1:3) trapizoidal drainage ditch
around the building sizee: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks
m2 40.71
3.0 Concrete Work
3.1 5 cm thick lean concrete C-5 under footing m2 4.00
3.2 Ditto, but under groung floor slab m2 9.30
Reinforced concrete with C - 25 Concrete Class for : -
3.3 Footings m3 1.00
3.4 Sub-grade columns m3 0.52
3.5 Grade beam m3 0.55
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 72 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13D- CONSTRUCTION OF GUARD HOUSE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
4.0 Sawn zigba or equivqlnet form work
4.1 To sides of footings m2 4.00
4.1 To sides of beams m2 5.52
4.1 To sides of sub-grade columns m 2
10.40
5.0 Mild steel rod reinforcement, including cutting, bending, & placing in
position
5.1 Diam 6mm deformed kg 5.00
5.2 Diam. 12mm deformed kg 142.80
B - SUPER STRUCTURE
6.0 Concrete Work IN CONCRETE C-25
6.1 In elevation columns m3 0.40
6.2 In suspended beams m3 0.55
6.3 In lintels m 3
0.10
6.4 Cement screed 3 cm thick for floor slab m2 9.30
7.0 Sawn zigba or equivqlnet form work
7.1 In elevation columns m2 9.60
7.2 In suspended beams m2 5.52
7.3 In lintels m2
1.2
8.0 Mild steel rod reinforcement, cutting, tying, bending, & placing in
position.
8.1 Diam. 6mm deformed kg 12.00
8.2 Diam. 8mm deformed kg 30.70
8.3 Diam.12mm deformed kg 137.10
9.0 Block Work
9.1 20 cm thick hollow concrete block walls m2 26.0
10.0 Roof work
10.1 Fabrication & Installation of eucalyptus truss as shown in the drawing No 3.00
10.2 5x7 cm zigba or equivqlnet wood purlin at 90cm spacing m 18.4
10.3
Guage 28 C.I.S. Roof cover including Ridge, Flushing and all incidental
works as shown in the drawing, the area is measured horizontally m2 21.62
10.4 20cm wide fascia board including paiting m 16.80
10.5
Gauge 28 galvanized iron sheet Gutter girth 60cm, welded at joints and
2% slope is provided towards the down pipes, price inclueds three
coats of oil paint. m 4.6
10.6 Ditto but 10x15cm Down pipe fixed to wall with metal straps m 4
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 73 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13D- CONSTRUCTION OF GUARD HOUSE CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
11.0
Metal Work for External Windows and Doors with LTZ black steeel
profile frame 38mm wide & 1.5mm thick all according to the drawing
with all grills, anti-rust and other paaintings and all handle and lock
accessories.
11.1 Windows
11.1.1 Size 120x70cm including 4mm thick glass pc. 1
11.2 DOORS
11.2.1 Size 210x70cm covered with metl sheet pc. 1
Floor Finish, Plastering & Pointing Work
12.0 Pointing
1.0 Recessed pointing to external masonry surface above the ground m2 5.50
2.0 Recessed pointing to external and internal works of HCB m2 25.50
3.0 3cm thick cement screed for the floors m 2
9.60
13.0 Electrical Installation
Supply and install of:
13.1 Sub-distribution board SDB for flush mounted complete with bars and
other accessories consisting of
2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
1pcs 32amp ABC 1-phase pcs 1.00
Light fitting with lumps (specified) type or equivalent
13.2 Philips TMS 012/140 with 1x40w flourescent lamp pcs 2.00
13.3 Light point fed through PVC insulated conductor
of 2x2,5mm2 in condute of dia.13mm under surface
including junction boxes with cover, legrand switches 2way etc. pcs 1.00
13.4 Flush mounted Legrand socket outlets of 16 amp/220v with
earthing contact fed through conductors of 3x2,5mm2
in conduit of min. dia.16mm in/under surface including
junction box with covers and installing screw caps etc. pcs 1.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
TOTAL FOR ONE GUARD HOUSE
BILL TOTAL FOR 6 NOS CARRIED TO SUMMARY

BOQ Page 74 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13E- CONSTRUCTION OF TOILET UNIT CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A. SUB-STRUCTURES
1.0 Earth Work
1.1 Site clearing to a depth of about 20 cm m2 108.00
1.2 Excavation in common soil for footing foundation & ground slab to a
depth not exceeding 1.5m m3 50.40
1.3 Excavation in common soil for footing foundation to a depth exceeding
1.5m but not 3m m3 30.30
1.4 Excavation in common soil for masonry trench to a depth not 20.40
exceeding 1.5m m 3

1.5 Cart away excavated material to a distance not exceeding 1km and 115.70
place as embankment protection m 3

1.6 Selected excavated fill material and compacted every 20cm layer to
standard proctor density. m3 7.00
1.7 Selected borrowed fill material and compacted every 20cm layer to 120.80
standard proctor density m 3

1.8 25 cm thick hard core filling and blinded with basaltic or equivalent
material m2 35.40
2.0 Stone Masonry
2.1 50cm width stone masonry wall , impermeable, non-weathered and
non-fractured stone buried inside the earth m3 18.00
2.2 50cm width stone masonry wall , impermeable, non-weathered and
non-fractured stone external surface left for pointing m3 6.00
2.3
One meter width semi dressed stone pavement around building and
jointed with cement mortar mix. 1:3 including earthworks and bedding m2 30.00
2.4
Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch
around the building size: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks. m2 78.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 75 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13E- CONSTRUCTION OF TOILET UNIT CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
3.0 Concrete Work
3.1 5 cm thick lean concrete C-5 under footing m2 9.00
3.2 Ditto, but under ground floor slab & beams m2 37.70
Reinforced concrete with C - 25 Concrete Class for : -
3.3 Footings m3 2.25
3.4 Sub-grade columns m3 1.20
3.5 Grade beams m3 1.5
4.0 Sawn zigba or equivqlnet form work
4.1 To sides of footings m2 9.00
4.2 To sides of beams m2 14.70
4.3 To sides of sub-grade columns m2 23.40
5.0 Mild steel rod reinforcement, cutting, bending, tying & placing in
position
5.1 Diam. 6mm bars for stirrups c/c 20cm kg 53.00
5.2 Diam. 8mm deformed for slab c/c 20cm kg 145.00
5.3 Diam. 10mm deformed for footing kg 125.00
5.4 Diam. 12mm deformed grade beams and sub-grade columns kg 288.00

B. SUPER-STRUCTURES
6.0 Concrete Work IN CONCRETE C-25
6.1 In elevation columns m3 1.08
6.2 In suspended beams m3 1.50
7.0 Sawn zigba or equivqlnet form work
7.1 In elevation columns m2 21.60
7.2 In suspended beams m2 14.70
8.0
Mild steel rod reinforcement, cutting, bending, & placing in position

8.1 Diam. 6mm stirrups @ 20 cm c/c for stirrups kg 52.00


8.2 Diam. 12mm deformed bars for beams & columns kg 240.00
9.0 Block Work
9.1 20 cm thick hollow concrete block walls m2 99.30
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 76 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13E- CONSTRUCTION OF TOILET UNIT CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
10.0 Roofing work
10.1 Fabrication & Installation of eucalyptus truss (10cm diam, c/c 1.3m) 7.00
No
with diagonal elements of 8cm diam.
10.2 5x7 cm zigba or equivqlnet wood purlin at 90cm spacing m 84.00
10.3 Gauge 28 C.I.S. Roof cover including Ridge, Flushing and all 57.12
incidental works as shown in the drawing, the area is measured m 2

horizontally
10.4 Gauge 28 galvanized iron sheet gutter girth 33 cm welded at joints and 17.00
2% slope is provided towards down pipe. Price shall include three ml
coats of oil paint
10.5 Ditto, but 75 mm down pipe fixed to wall with metal straps ml 18.60
11.0 Carpentry and Joinery
11.1 Supply &construct roof ceiling with 8mm chip wood on 4x5cm batten m2 28.00

Metal Work for External Windows and Doors with LTZ black steel
profile frame 38mm wide & 1.5mm thick all according to the drawing
with all grills, anti-rust and other paintings and all handle and lock
accessories.
Thick chicken wire (3mm to 5mm diam.) mesh and framed steel
12.0 windows
1 Size 330cm x 40cm pcs 4
13.0 Single metal door including keys and lockers
13.1 Size 70cmx210cm pcs 4.00
13.2 Size 60cmx210cm with internal metallic lock/lash pcs 10.00
Plastering & Pointing Work
14.0 Pointing
14.1 Recessed pointing to external masonry surface above the ground m2 11.00
14.2 3cm thick cement screed for the floors m 2
28.00
14.3 Two coats of plastering with cement mortar mix. 1:3 to surface of
a HCB and concrete internal wall surface m2 230.00
b HCB and concrete external wall surface m2 79.40
14.4 Fine coats cement plaster to surface of:-
a HCB and concrete internal wall surface m2 230.00
b HCB and concrete external wall surface m2 79.40
15.0 Terrazzo tile flooring & skirting
15.1 Terrazzo tile flooring m2 28.00
15.2 Terrazzo skirting size 10/2 cm ml 22.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 77 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13E- CONSTRUCTION OF TOILET UNIT CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
16.0 Ceramic wall tile
16.1 6 mm thick white ceramic wall tile m2 69.20
17.0 Window cill
17.1 Size 27/3 terrazzo window cill m 13.20
18.0 Steps
18.1 3 cm thick terrazo threads size 33x100 cm m2 3.96
18.2 3 cm thickterrazo risers size 15x100 cm m 2
1.80
19.0 Painting
19.1 Plastic emulsion paint
19.2 Plastered vertical wall surface m2 309.40
19.3 Chip wood ceiling m2 35.40
Sanitary Installation

Supply and construct PN16 GS, DCI or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts and earthworks for a
depth not less than 800mm.
20.0 Galvanized Steel Pipes
20.1 Diam. 5 mm ml 72.00
20.2 Diam. 18.75 mm ml 25.00
20.3 diam. 25 mm ml 12.00

Supply and construct PN4 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
21.0 PVC pipe for sewage drainage
21.1 Diam. 100 mm ml 25.60
22.0 Gate valves made of bronze approved by the Engineer
22.1 Diam. 5 mm pcs 14.00
22.2 Diam. 18.75 mm pcs 2.00
22.3 Diam. 25 mm pcs 1.00
23.0 WC and urinals
Turkish WC with high flush bowls including soap holder and all
23.1 accessories pcs 10.00
23.2 White Vitreous urinals pcs 2.00
23.3 Enameled steel grated floor drain diam. 50 mm pcs 2.00
White Vitreous hand wash basin with pedistal for cold water size
23.4 500x405mm pcs 8.00
23.5 500x400mm wide approved crystal glass mirror pcs 8.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 78 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13E- CONSTRUCTION OF TOILET UNIT CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
24.0 Electrical Installation
24.1 Cable ducts with inspection pits ml 100.00
Supply and install sub-distribution board SDB for flush mounted
24.2 complete with bars and other accessories consisting of pcs 1.00
24.3 uPVC feeder cable (4 x 10mm2) ml 100.00
24.4 uPVC feeder cable (3 x 2.5mm2) ml 300.00
24.5 Lighting points pcs 16.00
24.6 15 A single phase power points pcs 12.00
24.7 25 A three phase power points pcs 1.00
24.8 Fluorescent lighting (40W) pcs 10.00
24.9 Water proof bulkhead lighting pcs 9.00
24.1 Fluorescent lighting (60W) pcs 4.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

BOQ Page 79 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13F- CONSTRUCTION OF SHOWER ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A. SUB-STRUCTURES
1.0 Earth Work
1.1 Site clearing to a depth of about 20 cm m2 48.00
1.2 Excavation in common soil for footing foundation & ground slab to a 36.54
depth not exceeding 1.5m m 3

1.3 Excavation in common soil for footing foundation to a depth exceeding


1.5m but not 3m m3 27.00
1.4 Excavation in common soil for masonry trench to a depth not exceeding 16.50
1.5m m 3

1.5 Cart away excavated material to a distance not exceeding 1km and 83.64
place as embankment protection m 3

1.6 Selected excavated fill material and compacted every 20cm layer to
standard proctor density. m3 6.00
1.7 Selected borrowed fill material and compacted every 20cm layer to 141.98
standard proctor density m 3

1.8 25 cm thick hard core filling and blinded with basaltic or equivalent
material m2 16.60
2 Stone Masonry
2.1 50cm width stone masonry wall , impermeable, non-weathered and
non-fractured stone buried inside the earth m3 15.30
2.2 50cm width stone masonry wall , impermeable, non-weathered and
non-fractured stone external surface left for pointing m3 4.10
2.3
One meter width semi dressed stone pavement around building and
jointed with cement mortar mix. 1:3 including earthworks and bedding m2 27.00
2.4
Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch
around the building size: 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works incclude earthworks. m2 72.20
3.0 Concrete Work
3.1 5 cm thick lean concrete C-5 under footing m2 8.00
3.2 Ditto, but under ground floor slab & beams m 2
16.84
3.3 Reinforced concrete with C - 25 Concrete Class for : -
3.4 Footings m3 2.00
3.5 Sub-grade columns m3 1.04
3.6 Grade beams m3 0.93
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 80 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13F- CONSTRUCTION OF SHOWER ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
4.0 Sawn zigba or equivqlnet form work
4.1 To sides of footings m2 8.00
4.2 To sides of beams m2 9.30
4.3 To sides of sub-grade columns m2 9.00
5.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position

5.1 37.00
Diam. 6mm bars for stirrups c/c 20cm of beams & sub-grade columns kg
5.2 Diam. 8mm deformed for slab c/c 20cm kg 71.00
5.3 Diam. 10mm deformed for footing kg 77.00
5.4 Diam. 12mm deformed grade beams and sub-grade columns kg 210.00

B. SUPER-STRUCTURES
7.0 Concrete Work IN CONCRETE C-25
7.1 In elevation columns m3 0.80
7.2 In suspended beams m3 0.93
8.0 Sawn zigba or equivqlnet form work
8.1 In elevation columns m2 16.00
8.2 In suspended beams m2 9.00
9.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position

9.1 Diam. 6mm stirrups @ 20 cm c/c kg 35.00


9.2 Diam. 12mm deformed in suspended beams and columns kg 159.00
10.0 Block Work
10.1 20 cm thick hollow concrete block walls m2 83.84
11.0 Roofing work
11.1 Fabrication & Installation of eucalyptus truss (10cm diam, c/c 1.3m) with 9.00
No
diagonal elements of 8cm diam.
11.2 5x7 cm zigba or equivqlnet wood purlin at 90cm spacing m 30.40
11.3 Roof cover in gauge 28 C.I.S thick including roof ridge cover fixed to 36.00
steel purlins with dome shaped screws. Roof measured in horizontal
projections m2
11.4 Gauge 28 galvanized iron sheet gutter girth 33 cm welded at joints and 7.60
2% slope is provided towards down pipe. Price shall include three coats
of oil paint ml
11.5 Ditto, but 75 mm down pipe fixed to wall with metal straps ml 18.60
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 81 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13F- CONSTRUCTION OF SHOWER ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
12.00 Carpentry and Joinery
1.00 Supply &construct roof ceiling with 8mm chip wood on 4x5cm batten m2 16.6

Metal Work for External Windows and Doors with LTZ black steel
profile frame 38mm wide & 1.5mm thick all according to the drawing
with all grills, anti-rust and other paintings and all handle and lock
accessories.
13.00 Glazed and framed steel windows
13.1 Size 40x40cm pcs 5
Thick chicken wire (3mm to 5mm diam.) mesh and framed steel
14 windows
6.6.14. Size 100x40cm pcs 2
15 External single metal door
15.10 Size 70X210cm (top glazed for lighting) pcs 2.00
15.20 Size 60cmx210cm with internal metallic lock/lash pcs 5
16 Plastering & Pointing Work
16.10 Recessed pointing to external masonry surface above the ground m2 8.80
16.20 3cm thick cement screed for the floors m2 1.00
16.30 Two coats of plastering with cement mortar mix. 1:3 to surface of
a HCB & concrete internal wall surface m2 57.00
b HCB & concrete external wall surface m2 73.00
16.4 Fine coats cement plaster to surface of:-
a HCB & concrete internal wall surface m2 57.00
b HCB & concrete external wall surface m2 73.00
17 Terrazzo tile flooring & skirting
17.1 Terrazzo tile flooring m2 1.00
17.2 Terrazzo skirting size 10/2 cm ml 34.80
18 Ceramic wall tile
18.1 6 mm thick white ceramic wall tile m2 52.00
19 Window cill
19.1 Size 27/3 terrazzo window cill m 2.00
20.0 Steps
20.1 3 cm thick terrazo threads size 33x100 cm m2 0.99
20.2 3 cm thick terrazo risers size 15x100 cm m2 0.45
21.0 Plastic emulsion paint
21.1 Plastered vertical wall surface m2 130.00
21.2 Chip wood ceiling m2 16.60
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 82 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13F- CONSTRUCTION OF SHOWER ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Sanitary Installation

Supply and construct PN16 GS, DCI or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts and earthworks for a
depth not less than 800mm.
22.0 Galvanized Steel Pipes
22.1 Diam. 5 mm ml 15.00
22.2 Diam. 18.75 mm ml 17.00
22.3 diam. 25 mm ml 6.00

Supply and construct PN4 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
23.0 PVC pipe for sewage drainage
23.1 Diam. 100 mm ml 24.00
24.0 Gate valves made of bronze approved by the Engineer
24.1 Diam. 5 mm pcs 5.00
24.2 Diam. 18.75 mm pcs 1.00
24.3 Diam. 25 mm pcs 1.00
25.0 Showers

25.1 White plated metallic shower plate 0.8x0.8m with approved shower
head pcs 5
25.2 Enameled steel grated floor drain diam. 50 mm pcs 3.00
25.3 50x40cm wide approved crystal glass mirror pcs 3.00

25.4 White Vitreous hand wash basin with pedistal for cold water size
500x405 pcs 3.00
26.0 Electrical Installation
26.1 Cable ducts with inspection pits ml 30.00
26.2 Supply and install sub-distribution board SDB for flush mounted
complete with bars and other accessories consisting of pcs 1.00
26.3 uPVC feeder cable (4 x 10mm2) ml 100.00
26.4 uPVC feeder cable (3 x 2.5mm2) ml 200.00
26.5 Lighting points pcs 5.00
26.6 15 A single phase power points pcs 2.00
26.7 25 A three phase power points pcs
26.8 Fluorescent lighting (40W) pcs 3.00
26.9 Water proof bulkhead lighting pcs 3.00
26.1 Fluorescent lighting (60W) pcs 3.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

BOQ Page 83 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13G- CONSTRUCTION OF CONTROL & GENERATOR ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
A : SUB - STRUCTURE
1.0 Earthworks
1.1 Site clearing to a depth of about 20 cm m2 177.00
1.2 Excavation in common soil for footing foundation, ramp & ground to a
depth not exceeding 1.50 meters m3 103.00
1.3 Excavation in common soil for foundation to a depth not exceeding 3.00
meters m3 27.00
1.4 Excavation in common soil for trench along the outside perimeter to a
depth not exceeding 1.50 meters m3 19.00
1.5 Cart away excavated material to a distance not exceeding 1 km and
placing as flood protection embankment m3 184.40
1.6 Selected excavated fill material and compacted layer by layer m3 10.00
1.7 Selected borrowed fill material and compacted layer by layer for
footing, trench
25 cm thick and
hard bulkfilling
core fills and blinded with basaltic or equivalent m3 207.40
1.8 material for gen house and ramp slabs m 2
105.00
2 Stone Masonry
2.1 50cm wide stone masonry wall with dressed, impermeable, non- m3
weathered and non-fractured stone external surface left for pointing (for
the gen house perimeeterss, ramps and fuel tank seats).
20.00
2.2 50cm wide stone masonry wall with dressed, impermeable, non- m 4

weathered and non-fractured stone below the natural ground level


(depth about 1.5m)
50.00
2.3 One meter width semi dressed stone pavement around building and m 2

jointed with cement mortar mix. 1:3 and including earthworks & bedding
materials
23.00
2.4 Semi-dressed stone lined and pointed (1:3) trapezoidal drainage ditch m2
around the building size 50cm deep, 20cm bottom width and 20cm
shoulder on one side. Side slopes 1:1 & area in development length.
Works include earthworks.
39.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 84 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13G- CONSTRUCTION OF CONTROL & GENERATOR ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
3.0 Concrete Work
3.1 5 cm thick lean concrete C-5 under footing & grade beams m2 8.00
3.2 Ditto, but under ground floor slab, ramps and fuel tank seats m2 105.00
3.3 C-25 concrete in footings m 3
2.00
3.4 Ditto, but in foundation columns m3 1.10
3.5 Reinforced concrete in ground floor slab 15 cm thick with C-20 concrete m2
class 15.75
3.6 Reinforced concrete in grade beams with C-25 concrete class m3 1.00
3.7 Reinforced concrete in gen set seat icluding anchor bolt fixing with C-25
concrete class m3 2.25
4.0 Sawn zigba or equivqlnet form work
4.1 To sides of footings m2 8.00
4.2 To sides of foundation columns m2 21.00
4.3 To sides of grade beams m2 9.00
To sides of gen set seats and ramps m2 13.00
5.0
Mild steel rod reinforcement, cutting, bending, tying & placing in position
5.1 Diam. 8mm deformed kg 570.00
5.2 Diam. 10mm deformed for footing kg 77.00
5.3 Diam. 12mm deformed for columns and gen seat kg 353.00
B - SUPER STRUCTURE
6.0 Concrete Work IN CONCRETE C-25
6.1 In elevation columns m3 1.00
6.2 In suspended beams m3 1.00
6.3 In Generator seat including anchor bolt fixing m 3
0.72
6.4 In lintels m3 0.30
6.5 In 15 cm thick floor slab and ramps m 2
16.00
6.6 Cement screed 3 cm thick for floor slab m2 33.00
7.0 Sawn zigba or equivqlnet form work
7.1 In elevation columns m2 19.20
7.2 In suspended beams m2 15.00
7.3 In Generator seat m2 1.50
7.4 In lintels m2 5.80
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 85 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13G- CONSTRUCTION OF CONTROL & GENERATOR ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
9.0
Mild steel rod reinforcement, cutting, bending, & placing in position.
9.1 Diam. 8mm deformed kg 67.0
9.3 Diam.12mm deformed kg 240.0
10.0 Block Work
10.1
20 cm thick hollow concrete block walls including containement walls m2 69
10.2 Three coats of internal wall plastering with 1:3 cement mortar both for
concrete and block surfaces m2 87
10.3 Pointing of external wall with 1:3 cement mortar m 2
54.5
10.4 Three coats plastic emulsion paint internally m2 66
10.5 Pointing of external wall with 1:3 cement mortar for masonry wall
finishes including for ramps m2 57
11.0 Fabrication
Roof work & Installation of eucalyptus truss (10cm diam, c/c 1.3m) with
11.1 diagonal elements of 8cm diam. No 7
11.2 5x7 cm zigba or equivqlnet wood purlin at 90cm spacing m 84
11.3
Guage 28 C.I.S. Roof cover including Ridge, Flushing and all incidental
works as shown in the drawing, the area is measured horizontally m2 54
11.4 20cm wide fascia board including paiting m 28.00
11.5
Gauge 28 galvanized iron sheet Gutter girth 60cm, welded at joints and
2% slope is provided towards the down pipes, price inclueds three coats
of oil paint. m 14.40
11.6 Ditto but 10x15cm Down pipe fixed to wall with metal straps m 14

Metal Work for External Windows and Doors with LTZ black steel
profile frame 38mm wide & 1.5mm thick all according to the drawing
with all grills, anti-rust and other paintings and all handle and lock
accessories.
12.0 Windows
1.0 Metal framed windows with profiles cut and welded along the entire line
of contact and covered with chicken wire mesh. Size 150x150cm pc. 2
Ditto but size 150x100cm pc. 1
13.0 DOORS
13.1
Metallic sliding framed Doors with profiles cut and welded along the
entire line of contact and covered with 3mm thick metal sheet. The main
door will have internal small door. Size 300x300cm pc. 1
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 86 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13G- CONSTRUCTION OF CONTROL & GENERATOR ROOM CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
14.0 Glazing
14.1 4 mm thick m2 6
15.0 Sanitary
15.1 Provide and install 6000lit capacity fuel tank including pipes, fittings all
other accessories as shown in the drawing No 1
16.0 Electrical Installation
Supply and install of:
16.1 Sub-distribution board SDB for flush mounted
complete with bars and other accessories
consisting of:-
2 pcs 10amp ABC 1-phase
2 pcs 16amp ABC 1-phase
16.2 1pcs 32amp ABC 1-phase pcs 1.00
16.3 Light fitting with lumps (specified) type or equivalent
Philips TMS 012/140 with 1x40w flourescent lamp pcs 2.00
Philips TMS 065/118 with 1x20w flourescent lamp pcs 1.00
16.4 Light point fed through PVC insulated conductor
of 2x2,5mm2 in condute of dia.13mm under surface
including junction boxes with cover, switches 2 way etc. pcs 1.00
16.5 Flush mounted socket outlets of 16 amp/220v with
earthing contact fed through conductors of 3x2,5mm2
in conduit of min. dia.16mm in/under surface including
junction box with covers and installing screw caps etc. pcs 1.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

BOQ Page 87 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13H- CONSTRUCTION OF SITE WORK CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 External Water supply

Supply and lay PN16 GS, DCI, HDPE or uPVC pipes and fittings as per
the specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bolts and earthworks for a
depth not less than 800mm.
1.1 HDPE 50mm for main source m 1,200.00
1.2 HDPE 25mm m 150.00
1.3 HDPE 18.75mm m 48.00
1.4 HDPE 5mm for garden taps (the standing part shall be GS pipe). m 1,500.00
1.5 DN50mm gate valves with unions and other fitting materials No 2.00
1.6 DN25mm gate valves with unions and other fitting materials No 4.00
1.7 DN18.75mm gate valves with unions and other fitting materials No 6.00
1.8 DN5mm gate valves with unions and other fitting materials No 8.00
1.9 DN5mm taps with unions and other fitting materials. The standing part
shall be GS pipe with adaptor for HDPE. No 3.00
1.10
Supply and install circular plain concrete manhole (600mm internal
diameter, 1000mm depth & 60mm thickness) including earthworks and
cover for the valve chamber with locks arrangements No 12.00

2 External Sewerage

Supply and construct PN6 PVC pipes and fittings as per the
specification. Transport to site and store. The rate to include all
necessary fittings, gaskets, rubber seals, bedding and earthworks for a
depth not less than 800mm.
2.1 DN 110mm around the buildings m 96.00
2.2 DN 150mm collectors and main sewer m 630.00
2.3
Supply and install circular plain concrete manhole (600mm internal
diameter, 1000m - 2000mm depth & 60mm thickness) for main sewers
and house outlet connections. Costs including earthworks, cover, steps
and bottom benching. No 40.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 88 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13H- CONSTRUCTION OF SITE WORK CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
3.0 Electrical Site Work
See electro-mechanical part
ACCESS ROADS, WALKWAYS & PARKING AREAS

Roadways, Parking Area and Walkways Borrow Fill for Improved


Subgrade Layers & Gravel Wearing Course Compacted each layer in
150mm thickness to 95% of Modified AASHTO T180 Density
(According
Gravel MaintoRoads
ERA Manual -2002)
DS7 (Width = 6m & about 200m length up to the
4.0 Office)
4.1 Excavation of the unsuitable black soil for depth of about 600mm for the
main road as per the drawing (ditch excavation is included). m3 12,210
4.2 Cart away excavated material to a distance not exceeding 1km and
place as embankment protection m3 12,210
4.3 Cut and Borrow to fill as per the drawing
(a) Improved Subgrade Upper Layer 200mm thickness (G20) m3 2,560
(b) Improved Subgrade Lower Layer 600mm thickness (G7) m 3
13,320
Gravel Wearing Course and Shoulders as per the drawing
4.4 150mm thick Type 4 gravel wearing course m3 1,890

5.0
Gravel Minor Roads DS8 (Width = 4m & about 300m length for unit
operations and processes interconnections only)
5.1
Excavation of the unsuitable black soil for depth of about 600mm for
pond interconnecting roads as per the drawing (ditch excavation is
included). m3 6,786.00
5.2 Cart away excavated material to a distance not exceeding 1km and
place as embankment protection m3 6,786.00
5.3 Cut and Borrow to fill as per the drawing
(a) Improved Subgrade Upper Layer 200mm thickness (G20) m3 1,144.00
(b) m 3
Improved Subgrade Lower Layer 600mm thickness and above at river
crossings (G7) 6,786.00
Gravel Wearing Course and Shoulders as per the drawing
5.4 150mm thick Type 4 gravel wearing course m3 839.00

Gravel Minor Roads DS8 (Width = 4m & about 250m length on


embankments & 900m length cut sections around unit operations and
6 processes)
6.1 Cut and Borrow to fill as per the drawing
(a) Improved Subgrade Layer 300mm thickness (G7) m3 18,150.00
Gravel Wearing Course and Shoulders as per the drawing
6.2 150mm thick Type 4 gravel wearing course m3 7,260.00

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 89 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13H- CONSTRUCTION OF SITE WORK CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
7.0
Parking Areas & Walkways as DS8 and DS7 standards (Width of
walkway = 1.2m)
7.1 Excavation of the unsuitable black soil for depth of about 600mm for
parking area and 300mm for walkways layout as per the drawing. m3 499.00
7.2 Cart away excavated material to a distance not exceeding 1km and
place as embankment protection m3 499.00
7.3 Cut and Borrow to fill as per the drawing
(a) Improved Subgrade Upper Layer 200mm thickness (G20), only for m3
parking area 160.00
(b) Improved Subgrade Lower Layer 600mm thickness for parking area &
300mm for walkways (G7) 499.00
Gravel Wearing Course and Shoulders as per the drawing
7.4 150mm thick Type 4 gravel wearing course m3 130.00

Pre cast concrete curb stone in C-20 and chamfered all top edges
around parking area, round about, grass lots and for walkway sides.
Cost includes earthworks, formworks, concrete, etc.
7.5 Size 10/40cm m 400.00

DRAINAGE CHANNELS & PIPE CULVERTS


8.0

Supply and Construct Trapezoidal Paved Channel for Waterway on One


side of the Roads & along Flood Flows as per the drawings.
8.1 Lining with 300mm thick paved stones with mortar jointing/grouting of
the pieces (1:3 ratio). Area measured in development length m2 17,427.00
9.0 Supply and Construct Reinforced Concrete (RC) pipe culvert according
to D-03 ERA-2002 Manuals. All Class-B Bedding
9.1
Supply and lay φ900mm diameter RC pipe culvert every 500m of road
length and at every river crossing with Type-B bedding & 1:3 mortar
jointing m 140.00
9.2
Supply and construct Type-B masonry end walls with inlet/outlet lining
on both sides of the ends. (Lining is considered separately with channel
lining). m3 270.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BOQ Page 90 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A13H- CONSTRUCTION OF SITE WORK CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
10.0 FENCE
Provide and construct angle iron post fence ( 2.5m net height, 0.5m
embedment in concrete & c/c 2m, angle iron of 60x60x4mm) with
barbed wire mesh (2.5mm thickness, 8pcs horizontal & 2pcs diagonal)
10.1 and anchored with concrete at the bottom. Concrete dimension is
700x300x300mm, see drawings.
m 5,500.00
Provide and construct 6m wide double leaf and 1.75m high main gate
including anchors and lock sets. The gate is fixed on two 20cmX20cm
reinforced concrete columns (4φ12mm & stripps φ6mm c/c 200mm) and
framed with main 100mmX50mmX2mm RHS, 50x50x2mm sub-main
10.2 and with 20mmX20mmX2mm small bracings to spacing less than 30cm.
Metals are well coated with anti-rust and two coats of enamel paints.
See thedrawings.

No 1.00
10.3 Ditto but width 3m No 2.00

11.0 LANDSCAPING
Transportation of red lateritic soils of 300mm thick in the parking areas
and operator dwelling house and plant grasses on the green area and
11.1 other ornamental plant species around the grassing with follow ups till
transfer to the client.
m2 120.00
Plant and follow-up the growth of different plant species in rows by
using landscaping specialist and wwith the approval of the Engineer.
11.2 The lemons, oranges and bananas shall be located d/s to use the
effluent.

a Eucalyptus trees No 2,250.00


b Local acacias No 30.00
c Lemmons No 75.00
d Oranges No 75.00
e Banana No 75.00
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY

BILL TOTAL CARRIED SUMMARY

BOQ Page 91 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A14- CONSTRUCTION OF FLOOD PROTECTION (EMBANKMENT) CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
FLOOD PROTECTION WORKS
1.0 EARTHWORKS
Clearing and Grubbing including the top 20cm organic materials and
1.1 m2 6,500
vegetations to prepare the beds for embankment construction

Compaction and fill in successive layers to form embankment and


platform for flood protection works with selected excavated material from
the ponds, road and ditch excavations in the WWTPs. The cost includes
1.2 8,600
stockpiling, site to site hauling, placing and compaction in successive
layers. The embankment fill shall not be double counted as disposal in
the construction of WWTPs.
m3
1.3 Disposal of excavated materials within 5km distance m3 1,300
Supply and construct 300mm thick stone pitching 1.0m width bottom
1.4 portions the outside & inside slopes of embankment and around m2 1,500
culverts.

2.0 DRAINAGE WORKS

Supply and Construct Reinforced Concrete (RC) pipe culvert according


to D-03 ERA-2002 Manuals. All Class-B Bedding
Supply and lay φ900mm diameter RC pipe culvert river crossing with
2.1 Type-B bedding & 1:3 mortar jointing. The cost includes earthwork and 20
bedding. m
Supply and construct Type-B masonry end walls with inlet/outlet lining
2.2 on both sides of the ends. (Lining is considered separately with channel 30
lining). m 3

Excavate and construct earthen ditch to divert the flood water coming to
the anaerobic ponds and flood protection embankment. The ditch shall
2.3 1,800
have 3.0m bottom width, 1:2 (V:H) side slopes and variable depth (but
maximum 1.5m height).
m3
2.4 Disposal of excavated materials within 5km distance m3 1,800
PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY
BILL TOTAL CARRIED SUMMARY

BOQ Page 92 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


BILL No. A15- CONSTRUCTION OF OUTFALL STRUCTURES CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
1 EARTHWORKS
1.1 Common bulk excavation for all outfall structures (all depth ranges) m3 394
Compaction and fill in successive layers with selected excavated
1.2 m3 195
material
Disposal of excavated unsuitable and surplus materials within 5km
1.3 m3 199
distance
2 CONCRETE WORKS

Supply and construct impact type outfall structure at OF-01 as shown in


2.1 the drawing. Price includes concretes (C-5 for lean & C-25 for other 1
concretes), formworks, reinforcement, etc. No
2.2 Ditto but OF-02 as shown in the drawing. No 1
3 MASONRY WORKS
Supply and construct stone masonry wall with dressed, impermeable, m3
3.1 non-weathered and non-fractured stone 42

Supply and construct boulders and pebbles at the stilling basin as m3


3.3 shown in the drawing. 8

PAGE TOTAL CARRIED FORWARD TO BILL SUMMARY


BILL TOTAL CARRIED SUMMARY

BOQ Page 93 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


SCHEDULE OF DAY WORK RATES CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB
Schedule 1 : Labour

L.001 Labourer hr 200


L.002 Ganger hr 30
L.003 Bricklayer hr 30
L.004 Carpenter hr 30
L.005 Shutter hand hr 30

L.006 Steel fixer hr 30


L.007 Mason hr 30

Sub-total Labour
Allow ___percent of sub-total for Contractor's %
overheads, profit etc in accordance with parg. 3(b)

Schedule 2 : Materials
M.001 Cement kg 600
M.002 20mm Aggregate for concrete m3 50
M.003 Concrete sand m3 50
M.004 Dressed masonry m3 30
M.005 High tensile steel 500 Mpa (All diameters) kg 600
M.006 Mild steel 300 Mpa (All diameters) kg 100
M.007 100kg riprap m3 20
M.008 Dressed stone m2 50
M.009 Geomembrane ( ) m2 100

Sub-total for materials

Allow ___percent of sub-total for Contractor's %


overheads, profit etc in accordance with parg. 4(b)

BOQ Page 94 of 95
AKAKI CATCHMENTS WASTEWATER MANAGEMENT SYSTEM PROJECT

Akaki Sewage Treatment Works


SCHEDULE OF DAY WORK RATES CIVIL WORKS

ITEM DESCRIPTION UNIT QNTY RATE AMOUNT


No. ETB ETB

Schedule 3 : Construction Equipment

P.001 Concrete vibrator hr 30


P.002 Concrete mixer 14/10 hr 30
P.003 Dozer - Cat D7 or equivalent hr 30
P.004 Dozer - Cat D8 or equivalent hr 30

P.005 Excavator - Cat 320 or similar hr 30


P.006 Excavator - Cat 330 or similar hr 30
P.007 Front end loader < 1.5 cu.m capacity hr 30
P.008 Front end loader > 1.5 cu.m capacity hr 30
P.009 18 to 30 tone tipper truck hr 30
P.010 Water tank minimum capacity < 10000 litres hr 30

P.011 Water tank minimum capacity > 10000 litres hr 30

P.012 Steel flat wheel roller minimum mass 5 tons hr 30


P.013 Grid roller mass > 10 tons hr 30

P.014 Pneumatic tire roller mass > 10 tons hr 30


P.015 Small vibrating roller - Bomag 90 or similar hr 30
P.016 Crane > 5 tons hr 30
P.017 4 wheel drive pick-up hr 30
P.018 Compressor hr 30
P.019 Jack hammer hr 30
P.020 Water Pump hr 30
P.021 Plate compactor hr 30
Total carried to Summary

BOQ Page 95 of 95