NOTES:

1. Basic referance code:- IS 456: 2000


2. Due care shall be taken to ascertain that requisite strength of concrete is gained
before commencement of deshuttering. It shall comply with provisions of
Clause No. 11.3 of IS 456: 2000.
3. Deshuttering period shall not be less than specified below:
a) Veritcal faces of column, beams, & wall -24hrs.

b) Slabs I) Spanning upto 4.5m. -7 days

H = [ HEIGHT FROM PLINTH LEVEL


II) Spanning over 4.5m. -14 days
c) Beams I) Spanning upto 6.0m. -14 days

H = [ HEIGHT FROM PLINTH LEVEL


TO SLAB BEAM BOTTOM]
II) Spanning over 6.0m. -21 days

TO SLAB BEAM BOTTOM]


4. Nominal covers Mild Moderate Severe
I Footings 50 50 50
II Columns & walls >200mm width 40 40 45
(to links of column)
III Columns & walls having width of 200mm & below 40 40 45
having reinf. of dia. 16mm & above.
(to links of column)

C
IV Columns & walls having width of 200mm & below 25 30 45
having reinf. of dia. 12mm.
(to links of column)
V Slabs 20 30 45
VI Beams 20 30 45
(to stirrups of beam)
VII Lift wall 40 40 45

For main reinf. up to 12mm dia. bar for mild exposure the nominal cover
may be reduced by 5mm for slabs & beams only.
5. Beams having depth more than 750mm, provide side-face reinforcement.
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped

SITE CONDITION
HEIGHT AS PER
at any given section.

H = 1.5 X B
GRADE OF REINF. M20 M25 M30 M35 M40 & ABOVE
Fe415 55 X D 47 X D 44 X D 39 x D 35 x D
H = 1.5 X B

Fe500 (TMT) 66 X D 56 X D 53 X D 46 x D 42 x D
9. Maximum allowable height of column without any bracer or tie
I 230 wide 4000 mm.
II 200 wide 3400 mm.
III 150 wide 2600 mm.
10. All buildings shall have tie beams/plinth beams at ground/plinth level.
11. If footings overlap each other, necessary revision shall be obtained from our office.
12. Design is valid for number of floors as indicated in the drawing.
13. At any level where column size gets reduced in either dimension
B tie beams/plinth beams are essential.

C
14. For cantilevers, top bars to be anchored behind from external face of support for -
Ld or span of cantilever - whichever is greater.
SECTION C - C ELEVATION OF 15. Fire rating considered:- 1 Hour Max.
[ FIG. NO. - 100 ]
ECCENTRIC FOOTINGS
Use of this drawing for construction shall explicitly confirm acceptance of following conditions

DETAILS OF ECCENTRIC FOOTINGS by Owner / Builder / Contractor


1. Our responsibility shall remain limited to safe and sound structural design as transmitted
by this drawing and we shall not remain responsible for
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
and properties on adjoining roads.
Safety of construction worker/any personnel at work site during construction
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
any injury to any personnel arising out of any accidents.
NOTES = Accidents occurring due to premature deshuttering, faulty / substandard construction material or
workmanship / faulty construction procedure.
Any accident occurring due to construction of elements of buildings not designed by us.
PLEASE GIVE CLARIFICATION OF FOLLOWING POINTS:- 2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
1) BUILDING DESIGNED FOR (GROUND+2 FLOORS ONLY). 3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
2) COLUMNS ORIENTATION AS PER ARCHITECTURAL REQUIREMENT
3) FIGURE INDICATES DIRECTION FOR REDUCTION
C

OF COLUMN. NO. REV. DATE DESCRIPTION LIVE LOAD :- 200 kg/m2

R0 06-01-2020 FOR APPROVAL FLOOR FINISH :- 100 kg/m2

R1 OTHRE :- - - - -

R2 . . S. B. C. :- 32 T/m2

R3 . . GRADE OF CONCRETE :-

R4 . . FOR FOOTING :- M20


FOR COLUMN :- M20
R5 . . FOR SLAB & BEAM :- M20

R6 . . GRADE OF STEEL :- Fe 500


TIE BEAM
ENVIRONMENTAL
R7 . . EXPOSURE CONDITION :- MILD

DGN BY DRAWN BY SCALE DRG. NO. BLDG: JOB NO.

BUILDING 20:03
H = 1.5 X B

L
B
C

Er.P.T.CHAVAN Er. G.G.GHORI


CIVIL & CONSULTING STRUCTURAL DESIGNER &
PERSPECTIVE OF CREATIVE DESIGN ENGG. CONSULTING ENGG.
ECCENTRIC FOOTINGS AND MOB. - +91 7020028383 MOB. - +91 8793596857
CONSTRUCTION'S