4. REQUIREMENT FOR CONCRETE STRUCTURES
4.1 Grade of concrete
Grade of concrete shall be as follows:

Item Grade of Minimum Remark


Concrete Cement
content
kg/m 3

Pile M30 400 20mm down size aggregate


Pile cap / pedestal M30 320 20mm down size aggregate
Levelling Concrete PCC below RCC M15 240 75 mm thick with 40mm and down size
foundation, Raft aggregate and shall extend 50mm on all
sides
beyond the edges of foundation
Maximum cement content shall not exceed 450
4.2 Reinforc
Reinforcement steel shall be High strength deformed steel (TMT) bars of Grade Fe500 conforming to IS: 1786
4.3 Minimum Cover to main reinforce
Minimum cover for main reinforcement shall be as f

Sr. No. Member Minimum Cover

1 Pile cap (bottom) 100 mm


2 Pile cap (top and sides) 50 mm
3 Pedestal 50 mm
4 Tie beam 50mm