Immeuble Hajer, Rue Lac Victoria, 

3ème étage- les Berges du Lac - Rapport N°/Report N°:


1053 Tunis
Tél: +216 71 965200 Fax:+216
70 01 42 83 sis@sistn.com ULTRASONIC A-SCAN REPORT Page :
www.sistn,com
Date:

Client/Client: MARETAP Commande N°/Order N°: N°d'affaire/Job Ref:

Projet/Project:MARETAP FACILITIES INSP. Référence(s)/Standard(s): ASME V

Lieu/Location: CPF - Zarzis Procédure(s) interne(s)/Internal procedure(s):PQ-TEC-902

Description of Ultrasonic Equipment (UT)

Location: Between CPF and EZZ#1 Material: API 5L Gr B SCH 40

System: Flow line NPS: 4"

Coating Type: Fusion-Bonded Epoxy-Polurethane Foam Nominal thickness: 6.02 mm

Line Length: NG Construction year: 1989

GPS Location of the inspected parts : Area 1: Long.:11° 4min 7.06 sec E Lat.:33° 32min 11.74 sec N

Line pipe

Reference: USM-DMSGO Probe Frequency: 5MHZ

Serial N°: 14086133 Probe Serial N°: 500 495/51608

Couplant: Grease Ref step block: 55072

Min Th
Ref O'Clock Max Th
N° Ø (in) Nom Tk mm Ref Band Reading %Loss Comments
Point Position Reading (mm)
(mm)

LINE PIPE

Resultas 2015

12 To 6 4.21 5.72 30.07%


Area 1 P3 4 6.02 100% Note 1
6 To 12 3.94 5.77 34.55%

Resultas 2019

12 To 6 4.14 5.61 31.12%


Area 1 P3 4 6.02 100% Note 1
6 To 12 3.82 5.64 36.54%

Sketch / Drawings

1/2
NA: Not Accessible
NG: Not Given
Note 1: shall be monitored every year.
Note 2: shall be replaced.

SERVICES" Approuvé Par


Validation/Approval SIS "SMART INSPECTION SERVICES" Autre
inspector Approved By Other
Nom/Name Taoufik MCHABET Majdi JERBI
Date/Date
Signature/Signature

Ultrasonic A-Scan Report (FQ-TEC-904_IR:00_Edition:12/2015)