Вы находитесь на странице: 1из 3

Hinge Connection Design

A Reference code IS 800-2007

B Input
Fy (shear) = 21.8 kN (Node 65; LC-102)
Fz (Tension) = 21.6 kN
Fx (Shear) = 0 kN

C Tension
no of bolts = 2
Diameter of bolts = 12 mm2
Tension per bolt Ts = 10.80 kN
Area of bolt Asb = 113.04 mm2
Tensile stress per bolt = 95.54 N/mm2
fub Ultimate strength of
= 800
the bolts
An Nominal bore area = 0.78 x pi x d2/4
= 88.17 mm2
Design Tension capacity = 0.9 x fub x An
of bolt Tnb
= 0.9 x 800 x 88.17
= 63.48 kN

Permissible tensile stress 0.60 x Tnb /


=
of the bolt Asb
= 336.96 N/mm2

SAFE
D Shear
Maximum shear force at
support 21.8 kN
Shear force per bolt Vsb 10.90 kN

Actual shear stress in


Vsb/Asb
bolt fsb
10900
113.04

96.43 N/mm2

Nominal shear capacity


x (nnAnb + nsAsb)
of bolt Vnsb

52.21 kN

Permissible shear stress


0.6 x Vnsb/Asb
in bolt fasb

277.13 N/mm2

SAFE

E Check for Combined action

(fsb/fasb)2 + (ftb/fatb)2 96.43


+
63.48
= 0.536
277.13 336.96

< 1

SAFE
Hence use 2 M12 Grade 8.8 bolts for Hinge Connection.