Вы находитесь на странице: 1из 51

Type 3 Integrated input-output type

Fieldbus System (For Input/Output)


EX600 Series
®
Compatible Protocols

EX260
∗ Only the SY and
SV valves are
UL-compliant.

Type 1
RoHS

EX123/124/126
Made to Order
Please contact SMC for details on compatible products.

Dual-port SI unit
Wiring time can be reduced with
SPEEDCON (Phoenix Contact).

EX500
(EtherNet/IP )

Type 2
TM

product Just insert and make a 1/2 rotation!


 Can be used for linear type or
DLR type topology IP67
 Supports QuickConnect™ function

EX600
∗ Some products
 Status checks and settings can are IP40.
be performed on a web browser.

EX245
Handheld

Type 3
Terminal

EX250
Self Diagnosis Function
It is possible to ascertain the maintenance period

EX120/121/122
and identify the parts that require maintenance
by using the input/output open-circuit detection
function and the input/output signal ON/OFF
counter function. Also, the monitoring of input
and output signals and the setting of parameters
can be performed with the

EX140
handheld terminal.

Type 1

EX180

Max. 9 units∗1
can be connected in any order.
The input unit to connect input devices such
as auto switches, pressure switches, and
EX510

flow switches, and the output unit to


Type 2

connect output devices such as solenoid


valves, relays, and indicator lights can be
connected in any order.
∗1 Excludes SI units
M8/M12

Manifold Solenoid Valves


SY3000/5000/7000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000/5000 Series
ATEX

IP67 IP67 IP40 IP67

94 A
EX600 Series Configurations
Analog Units SI Unit
M12 connector (5 pins) Input device
Dual-port EtherNet/IPTM product
Input added to compatible
unit
2CH communication networks
p. 104
Output
unit
2CH Pressure
sensor
Flow sensor
Input/
Output 2CH/
unit 2CH Output device
IP67

Handheld Terminal
Parameter setting and
I/O monitor tool p. 106
IP67 IP67 Electro-pneumatic regulator, etc.

Input Input Input Output Input/Output Input Input/Output


unit unit unit unit unit unit unit
Units can be
differentiated
by color.

Power
supply

End
Plate Digital Units Analog Units SI Unit

For detailed specifications of connectable devices, refer to the catalog of each


device to select the right device for your application. If anything is unclear,
please contact SMC.

Digital Units
M12 connector (5 pins) M8 connector (3 pins) D-sub connector Spring type terminal block

Input
unit 8 inputs 16 inputs 8 inputs 16 inputs 16 inputs

Output
unit 8 outputs 16 outputs 16 outputs

Input/
Output 8 inputs/ 8 inputs/
unit 8 outputs 8 outputs

IP67 IP67 IP67 IP40 IP40

Input device Output device


Others Solenoid valve Others
Flow switch Auto switch
Proximity sensor Indicator light
Photoelectric switch Relay
Limit switch Buzzer

Pressure switch

95
SI Unit
Unit to connect various
Fieldbusses with the EX600
system
p. 104

EX260
SY Series (IP67)

Type 1
Digital Unit

EX123/124/126
Unit to input or output digital
(switch) signals
p. 105

EX500
Type 2
SV Series (IP67) Analog Unit
Manifold solenoid

EX600
valves
®

Unit to input or output analog


(voltage/current) signals
p. 105, 106

EX245
Type 3
End Plate

EX250
Unit to supply power to the
EX600 system
p. 106

S0700 Series (IP40)

EX120/121/122
Handheld Terminal
Parameter setting and I/O

EX140
Type 1
monitor tool
p. 106

VQC Series (IP67) EX180

Accessories
Options including a power supply cable,
EX510

etc., for the EX600 series


Type 2

M8/M12

p. 121

 Made to Order p. 128


ATEX

 MRP (PROFINET) compatible, Ethernet POWERLINK compatible


 Communication cable

96
Latest EtherNet/IP TM Technology
The following functions are available for the dual-port EtherNet/IPTM product (EX600-SEN3/4).
Added: Compatible Topologies (Connection Configuration)

EX600-SEN1/2 PLC Star type


The current single-port product
(EX600-SEN1/2) was only for star topology.

EtherNet/IPTM

Switching hub

EX600 q EX600 w EX600 e EX600 r

EX600-SEN3/4 The new dual-portproduct (EX600-SEN3/4) is available for both the


linear and device level ring topologies, in addition to the star type.

PLC PLC
Switching hub
is not required. Ring supervisor ∗1

Cable length can


be shortened.
EtherNet/IP TM
EtherNet/IPTM

EX600 q EX600 w EX600 e EX600 r EX600 q EX600 w EX600 e EX600 r

Linear type Device level ring (DLR) type


∗1 One or more ring supervisors are required.

For the device level ring type, even if the communication cable is disconnected in one location, EtherNet/IPTM
communication can be continued, and the disconnected portion can be specified by the ring supervisor.
PLC PLC

Ring supervisor Ring supervisor

Disconnected location

EX600 q EX600 w EX600 e EX600 r EX600 q EX600 w EX600 e EX600 r

Normal flow of data Data flow when the communication cable is disconnected

97
QuickConnectTM Function Available
From power ON to communication
connection
Approx. For tool changers, it takes about 10 seconds for communication to be

EX260
0.5 sec.
connected in common EtherNet/IPTM products after the power of the
10 sec. device installed on the tool is turned ON.

Type 1
Since the QuickConnectTM function∗1 is available for the EX600-SEN3/4,

EX123/124/126
communication can be connected in about 0.5 seconds.

Greatly reduces the


communication connection time
to the EtherNet/IPTM.
∗1 To use the QuickConnectTM function, the PLC
should be able to support the QuickConnectTM

EX500
Type 2
function.

EX600
Tool 2 Tool 3

EX245
Type 3
EX600
Robot arm

EX250
Tool 1 EX600 EX600

EX120/121/122
Built-in Web Server Function

EX140
Type 1
The EX600-SEN3/4 has a built-in web server function, which enables status checks, parameter settings, and
forced output of the EX600 using general-purpose web browsers, such as Internet Explorer. Start-up of the
system and maintenance can be performed efficiently. EX180

PLC

EX600 q to e
EX510

can be accessed
Type 2

via a web browser.


EtherNet/IPTM

Switching hub
M8/M12

 Status check
 Parameter setting
ATEX

EX600 q EX600 w EX600 e  Forced output, etc.

Connection example
98
Fieldbus System EX600
D-sub Connector IP40 Spring Type Terminal Block IP40
These units are capable of connection using a D-sub These terminal block units are compatible with indi-
connector. There are three types of units: for digital vidual wiring configurations. There are three types
input, output, and input/output. The digital output of units: for digital input, output, and input/output.
unit can be connected with an SMC manifold Wiring connection to a sensor connector box, etc.,
solenoid valve F kit (D-sub connector). can be carried out easily using only a flat head
Manifold solenoid valves can be connected screwdriver.
using a cable with a D-sub connector.
• SY series • S0700 series • SJ series • SQ series
• SV series • VQC series • VQ series
∗ Please limit the number of valve connections to 16 stations for single
and 8 stations for double. Refer to the catalog of each product for pin
assignment details.

Cable with D-sub connector

Sensor connector box


(Commercially available)

Digital Input Unit IP67 Analog Input/Output Unit IP67


This unit is for inputting a digital signal (ON/OFF These units are for inputting or outputting an ana-
signal). The signal of a 2-wire/3-wire auto switch at- log signal (voltage/current). A single unit performs
tached to the actuator can be acquired to feedback both input and output, allowing feedback control
a signal to the PLC. The control signal of an entire where analog signals are received from a pressure
system can be managed by a Fieldbus system. sensor and sent to a pressure controller. Installation
space is minimized as well.

Pressure
sensor
(PSE series)
Pressure controller
(Electro-pneumatic
Actuator regulator/ITV series)
Inlet
Auto switch pressure
side Outlet
pressure
side

A 99
EX260
Type 1

EX123/124/126
Self Diagnosis Function
In combination with the handheld terminal, the following two functions are available.
Short/Open-Circuit Detection Function Counter Function
It is possible to detect short or open circuits of input devices It is possible to ascertain the maintenance

EX500
Type 2
such as electronic 2-wire switches and 3-wire switches and period and identify the parts that require
output devices such as solenoid valves. The location of the error maintenance by an input and output signal
can be identified by the indicator light and the network. ON/OFF counter function. When the counter
function is enabled and a certain number of
contact operations is reached, the display of

EX600
the counter will flash in red.
∗ The counter function is not provided with analog
units.

EX245
Type 3
Green ON Normal Red ON Short circuit
Red flashing Open circuit

EX250
Handheld Terminal
Forced Input and Output Function Can be used for the adjustment of

EX120/121/122
The input and output signals are internal parameters and the monitoring
controlled forcedly without a PLC. The of input and output signal status
startup time after facility introduction Parameters: Analog data format
can be shortened. Analog measurement range
Input filter selection

EX140
Type 1
Counter function
Open-circuit detection
function, etc.
EX180
A parameter is a set value to change the
function and operation of the product
through a PLC or handheld terminal. The
desired operation for the customer’s
application is realized by the set values.
Password Setting Function
EX510
Type 2

There are some parameters that can only


be set using the handheld terminal of this
Simple Operation series.
Cursor button: Mode and setting change, etc.
Function key: Value and command entry, etc.
M8/M12
ATEX

100
Fieldbus System EX600
Individual units can be connected and removed one by one.
A unique clamping method is adopted to prevent screws from falling out.
Units can be separated easily by loosening the joint bracket.

It is also possible to add


and remove solenoid valve
stations on the manifold
one by one, but the
method is different.

101
5 - Port Solenoid Valves SY3000/5000/7000
Different sizes (SY3000/5000 or SY5000/7000) can be mixed! Overall length
of manifold
The installation area, amount of wiring, and number of SI units can
all be reduced. Approx. 22%
reduction
Single manifold Single manifold Mixed manifold

EX260
SY5000 3 stations SY3000 5 stations SY5000 3 stations SY3000 5 stations
Example of SY3000
and SY5000

Type 1
+

EX123/124/126
Installation
space

Approx. 102 mm Approx. 117 mm Approx. 170 mm

EX500
Type 2

EX600
Number of
SI units/

+
Unit cost

EX245
Type 3
Manifold 2 pcs. Manifold 1 pc.
Serial unit 2 sets Serial unit 1 set

EX250
Bottom-ported type is available!
Top or bottom porting allows for a reduced footprint.

EX120/121/122
EX140
Type 1

EX180

Installation
EX510

Panel fitting
Type 2

M8/M12
ATEX

102
CONTENTS
Parts Structure  p. 104
Type 3 Integrated input-output type How to Order
SI Unit  p. 104
Fieldbus System (For Input/Output) Digital Input Unit  p. 105
EX600 Series Digital Output Unit  p. 105
Digital Input/Output Unit  p. 105
Analog Input Unit  p. 105
Analog Output Unit  p. 106
Analog Input/Output Unit  p. 106
End Plate  p. 106
Handheld Terminal  p. 106
Specifications
All Units Common  p. 107
SI Unit  p. 107
Digital Input Unit  p. 109
Digital Output Unit  p. 110
Digital Input/Output Unit  p. 110
Analog Input Unit  p. 111
Analog Output Unit  p. 111
Analog Input/Output Unit  p. 112
End Plate  p. 112
Handheld Terminal  p. 112
Dimensions  p. 113
Parts Description  p. 115
LED Indicator  p. 117

Accessories
q End Plate Bracket  p. 121
w Valve Plate  p. 121
e Reinforcing Brace  p. 122
r Seal Cap (10 pcs.)  p. 122
t Marker (1 sheet, 88 pcs.)  p. 122
y Power Supply Cable (7/8 inch connector)  p. 122
u Power Supply Field-wireable
Connector (7/8 inch)  p. 123
i Power Supply Cable (M12 connector)  p. 123
o Communication Cable  p. 124
!0 Field-wireable Communication Connector  p. 126
!1 I/O Cable with Connector /I/O Connector  p. 127

Made to Order
q MRP (PROFINET) compatible  p. 128
w Ethernet POWERLINK compatible  p. 128
Communication Cable  p. 128

Specific Product Precautions  p. 132

103
Fieldbus System
For Input/Output

EX600 Series
* Only the SY and SV valves
are UL-compliant.

EX260
Parts Structure

Type 1

EX123/124/126
EX500
Type 2
SI unit

Analog input/output unit

EX600
Analog output unit

Analog input unit

EX245
Type 3
Digital input unit

EX250
EX120/121/122
Digital output unit

Digital input/output unit

EX140
Type 1
How to Order
EX180

SI Unit EX600 S PR1A


Made to Order
(Refer to page 128.)
EX510

Specifications
Type 2

MRP (PROFINET)
Symbol Protocol Output type Note
Ethernet POWERLINK
PR1A PNP (Negative common) —
PROFIBUS DP
PR2A NPN (Positive common) —
DN1A PNP (Negative common) —
DeviceNet™
DN2A NPN (Positive common) —
M8/M12

MJ1 PNP (Negative common) —


CC-Link
MJ2 NPN (Positive common) —
EN1 PNP (Negative common) —
EN2 NPN (Positive common) —
EtherNet/IP™
EN3 PNP (Negative common) 2 ports
EN4 NPN (Positive common) 2 ports
EC1 PNP (Negative common) —
ATEX

EtherCAT
EC2 NPN (Positive common) —
PN1 PNP (Negative common)
PROFINET
PN2 NPN (Positive common)
104 B
EX600 Series

How to Order

Digital Input Unit EX600 DX P D


Input type Number of Inputs, Open-circuit detection,
Symbol Description and Connector
P PNP
Symbol
Number of Open-circuit
Connector
N NPN inputs detection
B 8 inputs No M12 connector (5 pins) 4 pcs.
C 8 inputs No M8 connector (3 pins) 8 pcs.
C1 8 inputs Yes M8 connector (3 pins) 8 pcs.
D 16 inputs No M12 connector (5 pins) 8 pcs.
E 16 inputs No D-sub connector (25 pins)
F 16 inputs No Spring type terminal block (32 pins)

Digital Output Unit EX600 DY P B


Output type Number of Outputs and Connector
Symbol Description Number of
Symbol Connector
P PNP outputs
N NPN B 8 outputs M12 connector (5 pins) 4 pcs.
E 16 outputs D-sub connector (25 pins)
F 16 outputs Spring type terminal block (32 pins)

Digital Input/Output Unit EX600 DM P F


Input/Output type Number of Inputs/Outputs and Connector
Symbol Description Number of Number of
Symbol Connector
P PNP inputs outputs
N NPN E 8 inputs 8 outputs D-sub connector (25 pins)
F 8 inputs 8 outputs Spring type terminal block (32 pins)

Analog Input Unit EX600 AX A


Analog input Number of Input channels and Connector
Number of input
Symbol Connector
channels
A 2 channels M12 connector (5 pins) 2 pcs.

105
Fieldbus System
For Input/Output EX600 Series

How to Order

Analog Output Unit EX600 AY A

EX260
Analog output Number of Output channels and Connector
Number of output
Symbol Connector
channels
A 2 channels M12 connector (5 pins) 2 pcs.

Type 1

EX123/124/126
EX500
Type 2
Analog Input/Output Unit EX600 AM B
Analog input/output Number of Input/Output channels and Connector

EX600
Number of input Number of output
Symbol Connector
channels channels
M12 connector
B 2 channels 2 channels
(5 pins) 4 pcs.

EX245
Type 3

EX250
EX600 E D 2 2
EX600-ED4/5 are
End Plate (D side) not yet UL-compatible.

End plate Mounting method


Symbol Description Note

EX120/121/122
End plate mounting position: D side Nil Without DIN rail mounting bracket —
2 With DIN rail mounting bracket For SV, S0700, VQC series
Power supply connector
3 With DIN rail mounting bracket For SY series
Symbol Power supply connector Specifications
2 M12 (5 pins) B-coded IN * W
 hen the end plate (U side) is used, the symbol for the
mounting method must be the same as the D side.
3 7/8 inch (5 pins) IN
4 M12 (4/5 pins) A-coded*1 IN/OUT

EX140
Type 1
For M12 For 7/8 inch 5 M12 (4/5 pins) A-coded*1 IN/OUT
*1 T
 he pin layout for “4” and “5” pin connector
is different.
Refer to the dimensions on page 113. EX180

Handheld Terminal EX600 HT1A 3 Handheld terminals are


not yet UL-compatible.
EX510

Version Cable length


Type 2

Symbol Description
Nil No cable
1 1m
3 3m
M8/M12
ATEX

106 A
EX600 Series

Specifications

All Units Common Specifications


Operating temperature range Operating: –10 to 50°C, Stored: –20 to 60°C

Environmental resistance
Operating humidity range 35 to 85% RH (No condensation)
Withstand voltage*1 500 VAC for 1 minute between external terminals and FE
Insulation resistance*1 500 VDC, 10 MW or more between external terminals and FE
*1 Except handheld terminals

SI Unit (EX600-SPRlA)
Model EX600-SPR1A EX600-SPR2A
Protocol PROFIBUS DP (DP-V0)
Communication

Device type PROFIBUS DP Slave


Communication speed 9.6/19.2/45.45/93.75/187.5/500 kbps 1.5/3/6/12 Mbps
Configuration file GSD file*2
Occupation area Max. (512 inputs/512 outputs)
(Number of inputs/outputs)
Terminating resistor Internally implemented
Internal current consumption 80 mA or less
(Power supply for Control/Input)
Output type Source/PNP (Negative common) Sink/NPN (Positive common)
Number of outputs 32 outputs (8/16/24/32 outputs selectable)
Output

Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
EX600-SPRmA Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
*2 The setting file can be downloaded from the SMC website, http://www.smcworld.com

SI Unit (EX600-SDNlA)
Model EX600-SDN1A EX600-SDN2A
Protocol DeviceNet™: Volume 1 (Edition 2.1), Volume 3 (Edition 1.1)
Device type Group 2 Only Server
Communication

Communication speed 125/250/500 kbps


Configuration file EDS file*3
Occupation area Max. (512 inputs/512 outputs)
(Number of inputs/outputs)
Duplicate MAC ID Check Message, Group 2 Only Unconnected Explicit Message
Applicable messages
Explicit Message (Group 2), Poll I/O Message (Predefined M/S Connection set)
Applicable function QuickConnect TM
DeviceNet™ power supply 11 to 25 VDC (Current consumption 50 mA or less)
Internal current consumption 55 mA or less
EX600-SDNmA (Power supply for Control/Input)
Output type Source/PNP (Negative common) Sink/NPN (Positive common)
Number of outputs 32 outputs (8/16/24/32 outputs selectable)
Output

Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
*3 The setting file can be downloaded from the SMC website, http://www.smcworld.com

SI Unit (EX600-SMJl)
Model EX600-SMJ1 EX600-SMJ2
Protocol CC-Link (Ver. 1.10, Ver. 2.00)
Communication

Station type Remote Device Station


Communication speed 156/625 kbps 2.5/5/10 Mbps
Configuration file CSP+ file*4
Occupation area Max. (512 inputs/512 outputs)
(Number of inputs/outputs) 1/2/3/4 stations occupied
Internal current consumption 75 mA or less
(Power supply for Control/Input)
Output type Source/PNP (Negative common) Sink/NPN (Positive common)
Number of outputs 32 outputs (8/16/24/32 outputs selectable)
Output

Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
EX600-SMJm Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
*4 The setting file can be downloaded from the SMC website, http://www.smcworld.com

107
Fieldbus System
For Input/Output EX600 Series

Specifications

SI Unit (EX600-SENl)
Model EX600-SEN1 EX600-SEN2 EX600-SEN3 EX600-SEN4
Number of communication ports 1 port 2 ports

EX260
EtherNet/IP™ EtherNet/IP™
Protocol
(Conformance version: Composite 6) (Conformance version: Composite 11)
Communication speed 10/100 Mbps
Communication method Full duplex/Half duplex

Type 1
Communication Configuration file EDS file*1

EX123/124/126
Occupation area
Max. (512 inputs/512 outputs)
(Number of inputs/outputs)
IP address setting SI Unit switch settings: 192.168.0 or 1.1 to 254
EX600-SEN1/2 range Through DHCP server: Optional address
Vendor ID: 7 (SMC Corporation) Vendor ID: 7 (SMC Corporation)
Device information Device type: 12 (Communication Adapter) Device type: 12 (Communication Adapter)
Product code: 126 Product code: 203

EX500
Type 2
QuickConnect™
Applicable function — DLR
Web server function
Internal current consumption 120 mA or less
Output type Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common)

EX600
Number of outputs 32 outputs (8/16/24/32 outputs selectable) 32 outputs
Solenoid valve with surge voltage suppressor Solenoid valve with surge voltage suppressor
Output

Load
24 VDC, 1.5 W or less (SMC) 24 VDC, 1.0 W or less (SMC)
Power supply 24 VDC, 2 A
EX600-SEN3/4 Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection

EX245
Type 3
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
*1 The setting file can be downloaded from the SMC website, http://www.smcworld.com

SI Unit (EX600-SECl)

EX250
Model EX600-SEC1 EX600-SEC2
Protocol EtherCAT (Conformance Test Record V.1.2)
Communication

Communication speed 100 Mbps


Configuration file XML file*2
Occupation area

EX120/121/122
Max. (512 inputs/512 outputs)
(Number of inputs/outputs)
Internal current consumption
100 mA or less
(Power supply for Control/Input)
Output type Source/PNP (Negative common) Sink/NPN (Positive common)
Number of outputs 32 outputs (8/16/24/32 outputs selectable)
Output

Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
EX600-SECm Power supply

EX140
24 VDC, 2 A

Type 1
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
EX180
*2 The setting file can be downloaded from the SMC website, http://www.smcworld.com

SI Unit (EX600-SPNl)
Model EX600-SPN1 EX600-SPN2
Protocol PROFINET IO (PROFINET RT)
Communication

Communication speed 100 Mbps


EX510
Type 2

Configuration file GSDML file*3


Occupation area
Max. (512 inputs/512 outputs)
(Number of inputs/outputs)
Applicable function Fast Start Up
Internal current consumption
120 mA or less
(Power supply for Control/Input)
M8/M12

Output type Source/PNP (Negative common) Sink/NPN (Positive common)


Number of outputs 32 outputs
EX600-SPNm
Output

Load Solenoid valve with surge voltage suppressor 24 VDC, 1.0 W or less (SMC)
Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
ATEX

Enclosure IP67 (Manifold assembly)


Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g
*3 The setting file can be downloaded from the SMC website, http://www.smcworld.com
108
EX600 Series

Specifications

Digital Input Unit


Model EX600-DXPB EX600-DXNB EX600-DXPCl EX600-DXNCl EX600-DXPD EX600-DXND
Input type PNP NPN PNP NPN PNP NPN
Input connector M12 (5-pin) socket*1 M8 (3-pin) socket*3 M12 (5-pin) socket*1
Number of inputs 8 inputs (2 inputs/Connector) 8 inputs (1 input/Connector) 16 inputs (2 inputs/Connector)
Supplied voltage 24 VDC
0.5 A/Connector 0.25 A/Connector 0.5 A/Connector
Max. supplied current
2 A/Unit 2 A/Unit 2 A/Unit
Input

EX600-DXmB Protection Short-circuit protection


Input current (at 24 VDC) 9 mA or less
17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V)
ON voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V)
OFF voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
Open circuit 2 wires — 0.5 mA/Input*2 —
detection current 3 wires — 0.5 mA/Connector*2 —
Current consumption 50 mA or less 55 mA or less 70 mA or less
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
EX600-DXmCm Weight 300 g 275 g 340 g
*1 M12 (4-pin) connector can be connected.
*2 Function only applies to the EX600-DXlC1.
*3 When connecting the M8 plug connector, the tightening torque must be 0.2 N·m ±10%. If tightened with an
excessive tightening torque, this may cause the connector thread of the unit to break.

Model EX600-DXPE EX600-DXNE EX600-DXPF EX600-DXNF


Input type PNP NPN PNP NPN
D-sub socket (25 pins)
Input connector Spring type terminal block (32 pins)
Lock screw: No.4-40 UNC
EX600-DXmD Number of inputs 16 inputs 16 inputs (2 inputs x 8 blocks)
Supplied voltage 24 VDC
0.5 A/Block
Input

Max. supplied current 2 A/Unit


2 A/Unit
Protection Short-circuit protection
Input current (at 24 VDC) 5 mA or less
17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V)
ON voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V)
OFF voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
EX600-DXmE Applicable wire — 0.08 to 1.5 mm2 (AWG16 to 28)
Current consumption 50 mA or less 55 mA or less
Enclosure IP40 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g

EX600-DXmF

109
Fieldbus System
For Input/Output EX600 Series

Specifications

Digital Output Unit


Model EX600-DYPB EX600-DYNB EX600-DYPE EX600-DYNE EX600-DYPF EX600-DYNF
Output type PNP NPN PNP NPN PNP NPN

EX260
D-sub socket (25 pins) Spring type terminal block
Output connector M12 (5-pin) socket*1
Lock screw: No.4-40 UNC (32 pins)

Output
Number of outputs 8 outputs (2 outputs/Connector) 16 outputs 16 outputs (2 outputs x 8 blocks)

Type 1
Supplied voltage 24 VDC

EX123/124/126
0.5 A/Output
Max. load current
2 A/Unit
EX600-DYmB
Protection Short-circuit protection
0.08 to 1.5 mm2
Applicable wire — —
(AWG16 to 28)
Current consumption 50 mA or less

EX500
Type 2
IP67 IP40
Enclosure
(Manifold assembly) (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g

EX600
*1 M12 (4-pin) connector can be connected.
EX600-DYmE
EX600-DMmE
Digital Input/Output Unit
Model EX600-DMPE EX600-DMNE EX600-DMPF EX600-DMNF

EX245
Input/Output type PNP NPN PNP NPN

Type 3
D-sub socket (25 pins)
Connector Spring type terminal block (32 pins)
Lock screw: No.4-40 UNC
Number of inputs 8 inputs 8 inputs (2 inputs x 4 blocks)
Supplied voltage 24 VDC

EX250
0.5 A/Block
Max. supplied current 2 A/Unit
2 A/Unit
Input

Protection Short-circuit protection


EX600-DYmF
Input current (at 24 VDC) 5 mA or less
EX600-DMmF
17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V)

EX120/121/122
ON voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V)
OFF voltage
(At PNP input, between the pin for input terminal and supplied voltage of 0 V)
Number of outputs 8 outputs 8 outputs (2 outputs x 4 blocks)
Supplied voltage 24 VDC
Output

0.5 A/Output

EX140
Max. load current

Type 1
2 A/Unit
Protection Short-circuit protection
Applicable wire — 0.08 to 1.5 mm2 (AWG16 to 28)
Current consumption 50 mA or less 60 mA or less
Enclosure IP40 (Manifold assembly)
EX180

Standards CE marking, UL (CSA), RoHS compliant


Weight 300 g
EX510
Type 2

M8/M12
ATEX

110
EX600 Series

Specifications

Analog Input Unit


Model EX600-AXA
Input type Voltage input Current input
Input connector M12 (5-pin) socket*1
Input channel 2 channels (1 channel/Connector)
Supplied voltage 24 VDC
Max. supplied current 0.5 A/Connector
Protection Short-circuit protection
Input

Input 12 bit resolution 0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA


signal range 16 bit resolution –10 to 10 V, –5 to 5 V –20 to 20 mA
EX600-AXA
Max. rated input signal ±15 V ±22 mA*2
Input impedance 100 kW 50 W
Linearity (25°C) ±0.05% F.S.
Repeatability (25°C) ±0.15% F.S.
Absolute accuracy (25°C) ±0.5% F.S. ±0.6% F.S.
Current consumption 70 mA or less
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 290 g
*1 M12 (4-pin) connector can be connected.
*2 When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.

Analog Output Unit


Model EX600-AYA
Output type Voltage output Current output
Output connector M12 (5-pin) socket*3
Output channel 2 channels (1 channel/Connector)
Supplied voltage 24 VDC
Max. load current 0.5 A/Connector
Output

Protection Short-circuit protection


Output
12 bit resolution 0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA
signal range
EX600-AYA
Load impedance 1 kW or more 600 W or less
Linearity (25°C) ±0.05% F.S.
Repeatability (25°C) ±0.15% F.S.
Absolute accuracy (25°C) ±0.5% F.S. ±0.6% F.S.
Current consumption 70 mA or less
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 290 g
*3 M12 (4-pin) connector can be connected.

111
Fieldbus System
For Input/Output EX600 Series

Specifications

Analog Input/Output Unit


Model EX600-AMB
Input type Voltage input Current input

EX260
Input connector M12 (5-pin) socket*1
Input channel 2 channels (1 channel/Connector)
Supplied voltage 24 VDC

Type 1
Max. supplied current 0.5 A/Connector

EX123/124/126
Protection Short-circuit protection
Input

Input 12 bit
0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA
signal range resolution
EX600-AMB Max. rated input signal 15 V 22 mA*2
Input impedance 100 kW 250 W
Linearity (25°C) ±0.05% F.S.

EX500
Type 2
Repeatability (25°C) ±0.15% F.S.
Absolute accuracy (25°C) ±0.5% F.S. ±0.6% F.S.
Output type Voltage output Current output
Output connector M12 (5-pin) socket*1

EX600
Output channel 2 channels (1 channel/Connector)
Supplied voltage 24 VDC
Max. load current 0.5 A/Connector
Output

Protection Short-circuit protection


Output 12 bit
0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA

EX245
signal range resolution

Type 3
Load impedance 1 kW or more 600 W or less
Linearity (25°C) ±0.05% F.S.
Repeatability (25°C) ±0.15% F.S.
Absolute accuracy (25°C) ±0.5% F.S. ±0.6% F.S.

EX250
Current consumption 100 mA or less
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g

EX120/121/122
*1 M12 (4-pin) connector can be connected.
*2 When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.

End Plate
Model EX600-ED2- EX600-ED3- EX600-ED4/5-

EX140
Type 1
Power supply PWR IN M12 (5-pin) plug 7/8 inch (5-pin) plug M12 (4-pin) plug
Power specifications

connector PWR OUT — — M12 (5-pin) plug


Rated Power supply for control/input 24 VDC ±10%
voltage Power supply for output 24 VDC +10/–5%
Rated Power supply for control/input
EX180
Max. 2 A Max. 8 A Max. 4 A
current Power supply for output
EX600-ED3-m Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant*1
EX600-ED2/4/5-m Weight 170 g 175 g 170 g
*1 The EX600-ED4/5- is not compliant with UL (CSA) standards.
EX510
Type 2

Handheld Terminal
Model EX600-HT1A-l
M8/M12

Power supply Power supplied from SI unit connector (24 VDC)


Current consumption 50 mA or less
Display LCD with backlight
Handheld terminal cable
Connection cable
(1 m ··· EX600-AC010-1, 3 m ··· EX600-AC030-1)
Enclosure IP20
ATEX

EX600-HT1A-m Standards CE marking, RoHS compliant


Weight 160 g

112 A
EX600 Series

Dimensions
SI Unit 10.7 55.2 10.7 55.2
47 47
EX600-SPRlA 26 EX600-SENl 26

23.7
EX600-SDNlA EX600-SECl
EX600-SMJl EX600-SPNl
106

106
22

22
11.5

106.5

8
56.4

56.4
22.1

22.1

End plate (D side)


(4.4) EX600-ED2
EX600-ED2/ED4/ED5 26 5.5
2 x M4 direct mounting hole
Power supply connector PWR IN: M12 5-pin plug, B-coded
85.1 20.5 Power supply connector Configuration Pin no. Description
PWR IN 1 24 V (for output)
8

2 1 2 0 V (for output)
5 3 24 V (for control/input)
3 4 4 0 V (for control/input)
5 FE
106

30.35
90

29

Power supply connector PWR IN: M12 4-pin plug, A-coded


EX600-ED4 (Pin arrangement 1) EX600-ED5 (Pin arrangement 2)
Configuration
Pin no. Description Pin no. Description
Power supply connector
PWR OUT 3 2 1 24 V (for control/input) 1 24 V (for output)
FE terminal 2 24 V (for output) 2 0 V (for output)
3 0 V (for control/input) 3 24 V (for control/input)
4 1 4 0 V (for output) 4 0 V (for control/input)

Power supply connector PWR OUT: M12 5-pin socket, A-coded


(86.6)
73.6

EX600-ED4 (Pin arrangement 1) EX600-ED5 (Pin arrangement 2)


56.6

Configuration
Pin no. Description Pin no. Description
30.2

1 24 V (for control/input) 1 24 V (for output)


13.2

1 2
2 24 V (for output) 2 0 V (for output)
3 0 V (for control/input) 3 24 V (for control/input)
42.5 5.5 4 0 V (for output) 4 0 V (for control/input)
EX600-ED3 4 5 3
5 Unused 5 Unused
26
2 x M4 direct mounting hole 20.5
8
106

30.35
90

Power supply connector PWR: 7/8 inch 5-pin plug


Configuration Pin no. Description
1 0 V (for output)
1 5 2 0 V (for control/input)
3
56.6

2 4 FE
36.65

4 24 V (for control/input)
30.2

3
13.2

5 24 V (for output)
A 113
76

EX600-HT1A
Dimensions
Handheld Terminal

170
(39.6)
20
For Input/Output
Fieldbus System
EX600 Series

113-1 A
Type 2 Type 1 Type 3 Type 2 Type 1

ATEX M8/M12 EX510 EX180 EX140 EX120/121/122 EX250 EX245 EX600 EX500 EX123/124/126 EX260
Fieldbus System
For Input/Output EX600 Series

Dimensions
Digital Unit
EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE
EX600-DYlB EX600-DYlE
EX600-DMlE

EX260
10.7 52.5 10.7 52.5 10.7 52.5
47 47 47 10.7 52.5
20 23 20 47

Type 1

EX123/124/126
106

106
106

81
27

106
43.5
14.5
37

EX500
Type 2
0.3

EX600
3
8
8

56.4
56.4

56.4
56.4

22.1
22.1

22.1
22.1

EX245
Type 3
Analog Unit

EX250
EX600-DXlF EX600-AXA EX600-AMB
EX600-DYlF EX600-AYA
EX600-DMlF
10.7 52.5 10.7 52.5
10.7 52.5 47 47

EX120/121/122
47 20 20

EX140
106

Type 1
106
106

37

EX180
2.2

8
8
56.4

EX510
56.4

Type 2
56.4
22.1

22.1
22.1

M8/M12
ATEX

114
EX600 Series

Parts Description
SI Unit
w
q e r
No. Name Use
t
1 Status indication LED Displays unit status
2 Indication cover Open for setting the switch.
y 3 Indication cover set screw Loosen for opening the indication cover.
Connects to the fieldbus output cable
4 Connector (BUS OUT)
(SPEEDCON)
5 Marker groove Can be used to mount a marker
!1
u Connects to the handheld
i qw
6 Connector (PCI)
!0 terminal cable (SPEEDCON)
o e t 7 Valve plate mounting holes Fixes a valve plate in place
EX600-SPRlA
EX600-SMJl 8 Valve plate mounting groove Inserts a valve plate
EX600-SDNlA y 9 Joint bracket Links units to one another
Transmits signals to the neighboring
10 Connector for unit (Plug)
q w e r !2 unit and supplies power
Connects to the cable for fieldbus
t 11 Connector (BUS IN)
input (SPEEDCON)
!1
y !0 u 12 MAC address name plate*1
Displays a unique 12-digit MAC
i address for each SI unit

EX600-SEN1/2
o Mounted on the connectors (BUS OUT
!2 13 Seal cap
and PCI) at the time of shipment
*1 MAC address name plate is not provided on the EX600-SEC.
!1 !3
!0 u
q i
EX600-SEN3/4 o
EX600-SECl
EX600-SPNl

Handheld Terminal
No. Name Use
q Displays operation and unit
1 LCD
information
Connects to the handheld terminal
2 Connector
cable
Connects the SI unit to the handheld
3 Handheld terminal cable
terminal
e From the selection screen, goes to
the screen for the item selected
4 Enter button ( )
On the settings screen, registers the
settings that have been made so far
Moves the cursor on the LCD up,
down, left or right
w Cursor button
Moves the cursor on the selection
screen up, down, left or right to make
5
( ) selections
On the settings screen, increases or
decreases the value of settings or
!0 r turns settings on and off
Functions in accordance with
6 F2 button ( )
o on-screen display or instructions
Functions in accordance with
7 F1 button ( )
on-screen display or instructions
i t On the selection screen, goes back to
the previous screen
8 Escape button ( ) On the settings screen, cancels the
settings that have been made so far
and goes back to the previous screen
Lights up red when the EX600
9 ERROR LED
diagnosis errors occur
Connects to the EX600 SI unit, and
u y 10 POWER LED lights up green when control/input
power supply is on
Operation buttons
115
Fieldbus System
For Input/Output EX600 Series

Parts Description
Digital Unit

q w q w No. Name Use


e e

EX260
1 Status indication LED Displays unit status
Connects with input or output devices
2 Connector (Only the EX600-DmmB and EX600-

Type 1
DXmD are SPEEDCON compatible.)

EX123/124/126
3 Marker groove Can be used to mount a marker
Secures the D-sub connector in place
4 Lock screw
(No.4-40 UNC)
5 Joint bracket Links units to one another
y y 6 Connector for unit (Plug)
Transmits signals to the neighboring
unit and supplies power
EX600-DXlB t EX600-DXlCl t

EX500
Type 2
EX600-DYlB
q w q q
w
e e w e
r

EX600
EX245
Type 3
y y y
EX600-DXlD t EX600-DXlE t EX600-DXlF t
EX600-DYlE EX600-DYlF
EX600-DMlE EX600-DMlF

EX250
Analog Unit

q w q w No. Name Use

EX120/121/122
e e 1 Status indication LED Displays unit status
Connects with input or output devices
2 Connector
(SPEEDCON)
3 Marker groove Can be used to mount a marker
4 Joint bracket Links units to one another

EX140
Transmits signals to the neighboring

Type 1
5 Connector for unit (Plug)
unit and supplies power

t t
EX600-AXA r EX600-AMB r
EX180
EX600-AYA

End Plate
EX510

q t
Type 2

No. Name Use


Supplies power to the unit and/or
1 Power connector input/output device (Only the EX600-
ED2-m is SPEEDCON compatible.)
q
Fixing hole for direct
2 Connects directly to equipment
M8/M12

mounting
Converts to manifold or for DIN rail
3 Fixing hole for DIN rail
mounting
Used for grounding
w w 4 FE terminal Ground this terminal securely to
e e
improve noise immunity.
ATEX

This connector has not yet been used.


EX600-ED2-l EX600-ED3-l 5 Connector (Unused)
r w r w Do not remove the seal cap.
e e
116
EX600 Series

LED Indicator
EX600-SPRmA EX600-SDNmA

ST(M): Unit diagnostic state ST(M): Unit diagnostic state


BF: Communication state NS: Communication state

PWR: Power supply PWR: Power supply


for control and input SF: System state for control and input MS: Unit state

PWR(V): Power supply


PWR(V): Power supply
for output
for output

EX600-SEN1/SEN2 EX600-SEN3/SEN4

ST(M): Unit diagnostic state ST(M): Unit diagnostic state


NS: Communication state NS: Communication state

PWR: Power supply PWR: Power supply


for control and input MS: Unit state for control and input MS: Unit state

PWR(V): Power supply PWR(V): Power supply


for output for output

BUS IN
Communication state BUS OUT
Communication state

EX600-SECm EX600-SPNm

ST(M): Unit diagnostic state ST(M): Unit diagnostic state


ERR: Communication BF: Communication
error display error display

PWR: Power supply PWR: Power supply


for control and input RUN: Communication state for control and input SF: System state

PWR(V): Power supply PWR(V): Power supply


for output for output

BUS IN BUS IN
Communication state BUS OUT Communication state BUS OUT
Communication state Communication state

117
Fieldbus System
For Input/Output EX600 Series

LED Indicator
EX600-SMJm EX600-DXmB

PWR: Power supply

EX260
for control and input
LRUN: Communication state
ON/OFF state of the

Type 1
input device

EX123/124/126
PWR: Power supply
for control and input LERR: Communication
error display
PWR(V): Power supply
for output

EX500
Type 2

EX600
EX600-DXmC EX600-DXmD

EX245
Type 3
ON/OFF state of the ON/OFF state of the
input device input device

EX250
EX120/121/122
EX140
Type 1

EX600-DXmE EX600-DXmF EX180

ON/OFF state of the ON/OFF state of the


input device input device
EX510
Type 2

ST: Diagnostic state of the ST: Diagnostic state of the


input device input device
M8/M12
ATEX

118
EX600 Series

LED Indicator
EX600-DYmB EX600-DYmE

ON/OFF state of the ON/OFF state of the


output device output device

ST: Diagnostic state of the


output device

EX600-DYmF EX600-DMmE

ON/OFF state of the ON/OFF state of the


output device ST(I): Diagnostic state of the output device
input device

ST: Diagnostic state of the ST(O): Diagnostic state of the


output device output device

ON/OFF state of the


input device

EX600-DMmF EX600-AXA

ON/OFF state of the


ST(I): Diagnostic state of the output device
input device

ST(O): Diagnostic state of the Diagnostic state of the


output device input device

ON/OFF state of the


input device

119
Fieldbus System
For Input/Output EX600 Series

LED Indicator
EX600-AYA EX600-AMB

EX260
Diagnostic state of the
input device

Type 1

EX123/124/126
Diagnostic state of the Diagnostic state of the
output device output device

EX500
Type 2

EX600
EX245
Type 3

EX250
EX120/121/122
EX140
Type 1

EX180
EX510
Type 2

M8/M12
ATEX

120
EX600 Series
Accessories

!0 Communication cable
o Power supply cable !1 Field-wireable communication
(M12 connector) t Seal cap connector
(M8)
!2 I/O cable with
connector

y Marker
w Valve plate
(When the valve
manifold is in use)

t Seal cap
(M12)

u Power supply
cable
(7/8 inch
r Reinforcing brace
(for direct mounting)
connector)

e End Plate (U side)


(When the valve manifold
is not in use)

r Reinforcing brace
(for DIN rail mounting)

q End plate bracket


i Power supply field-wireable
connector (7/8 inch)

q End Plate Bracket


This bracket is used for the end plate of DIN rail mounting.

EX600-ZMA2 EX600-ZMA3
(Specialized for SY series)

Enclosed parts Enclosed parts


Round head screw (M4 x 20) 1 pc. Round head screw with washer (M4 x 20) 1 pc.
P-tight screw (4 x 14) 2 pcs. P-tight screw (4 x 14) 2 pcs.

w Valve Plate

EX600-ZMV1 EX600-ZMV2
(Specialized for SY series)

Enclosed parts Enclosed parts


Round head screw (M4 x 6) 2 pcs. Round head screw (M4 x 6) 2 pcs.
Round head screw (M3 x 8) 4 pcs. Round head screw (M3 x 8) 4 pcs.

A 121
Accessories EX600 Series

e End Plate (U side)


The end plate is for use when the manifold valve is not connected.

EX600- E U 1 -  2 EX600-EU1
28.2 26 2 x M4 direct mounting hole

EX260
20.5
Mounting method
Symbol Description

8
Nil

Type 1
Without DIN rail mounting bracket
2 With DIN rail mounting bracket

EX123/124/126
3 With DIN rail mounting bracket
* S
 elect in accordance with the symbol for
the end plate (D side) mounting method.

106
90
Specifications

EX500
Symbol Specifications

Type 2
4.6
1 Waterproof cover

End plate mounting position: U side


End plate

EX600
SI unit mounting hole x 2

56.6
13.2
13 18.2

EX245
4.1

Type 3
9.1
6.7

Enclosed parts
Round head screw (M4 x 5) 2 pcs.

EX250
r Reinforcing Brace
This bracket is used on the bottom of the unit at the intermediate position for connecting 6 units or more.

EX120/121/122
* Be sure to attach this bracket to prevent connection failure between the units caused by deflection.

For direct mounting For DIN rail mounting


EX600-ZMB1 EX600-ZMB2

EX140
Type 1
Enclosed parts Enclosed parts
Round head screw (M4 x 5) 2 pcs. Round head screw (M4 x 6) 2 pcs.

EX180

t Seal Cap (10 pcs.) y Marker (1 sheet, 88 pcs.)


Be sure to mount a seal cap on any unused I/O connectors. The signal name of I/O device and each unit address can be
EX510

Otherwise, the specified enclosure cannot be maintained. entered and mounted on each unit.
Type 2

EX9-AWES EX9-AWTS EX600-ZT1


For M8 For M12
M8/M12
ATEX

122 A
EX600 Series

u Power Supply Cable (7/8 inch connector)


PCA-1558810 Straight 2 m
PCA-1558823 Straight 6 m
PCA-1558836 Right angle 2 m
PCA-1558849 Right angle 6 m
Straight connector type Angle connector type
49.9 L 53 L

3 36

26.5
2 4

40.4
ø7/8"
ø26

ø12.58
1 5
ø12.58

Socket pin ø7/8"


arrangement ø26
1 2

3 Socket pin arrangement


Core wire Core wire
5 4
color color
1 Red/White: 0 V (For output) 1 Red/White: 0 V (For output)
2 Red: 0 V (For control and input) 2 Red: 0 V (For control and input)
3 Green: FE 3 Green: FE
4 Red/Orange: 24 VDC±10% (For control and input) 4 Red/Orange: 24 VDC±10% (For control and input)
5 Red/Black: 24 VDC +10%/–5% (For output) 5 Red/Black: 24 VDC +10%/–5% (For output)

Connections Connections
Item Specifications
Cable O.D. ø12.58 mm
Conductor nominal cross section 1.5 mm2/AWG16
Wire O.D. (Including insulator) 2.35 mm
Min. bending radius (Fixed) 110 mm

i Power Supply Field-wireable Connector (7/8 inch)


PCA-1578081 Socket [compatible with AWG22-16]
Applicable Cable
Item Specifications
Cable O.D. ø12.0 to 14.0 mm
Wire gauge (Stranded 0.34 to 1.5 mm2
wire cross section) AWG22 to 16

o Power Supply Cable (M12 connector, For EX600-ED2) * The shape of the M12 connector is B-coded (Reverse key).
PCA-1564927 Straight 2 m
PCA-1564930 Straight 6 m
PCA-1564943 Right angle 2 m
PCA-1564969 Right angle 6 m

Straight connector type Angle connector type


36.3 L 50
ø14.8

44.5 L 50
22.5
22.5
28

Marker tag Marker tag


ø5.9
ø5.9

Marker tag Marker tag


M12
M12 ø14.8
SPEEDCON
SPEEDCON

Core wire Core wire


Terminal no. color Terminal no. color
5 1 2 1 Brown: 24 VDC +10%/–5% (For output) 5 1 2 1 Brown: 24 VDC +10%/–5% (For output)
2 White: 0 V (For output) 2 White: 0 V (For output)
3 Blue: 24 VDC±10% (For control and input) 3 Blue: 24 VDC±10% (For control and input)
4 Black: 0 V (For control and input) 4 Black: 0 V (For control and input)
4 3 5 Gray: Not connected 4 3 5 Gray: Not connected

Socket connector Connections Socket connector Connections


pin arrangement pin arrangement
B-coded (Reverse key) B-coded (Reverse key) Item Specifications
Cable O.D. ø5.9 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.27 mm
Min. bending radius (Fixed) 59 mm
A 123
Accessories EX600 Series

!0 Power Supply Cable (M12 connector, For EX600-ED4/5) * The shape of the M12 connector is A-coded (Reverse key).

EX500-AP  050  -  S


Cable length (L) Connector specification
010 1000 mm S Straight

EX260
050 5000 mm A Angle

Type 1
Straight connector type Angle connector type

EX123/124/126
M12
ø14.9
ø14.9

M12
1 2 1 2

ø6
ø6

28.3
5 5

EX500
Type 2
4 3 27 30 5 4 3 25.3 30 5
Socket connector 40.7 50 Socket connector L 50
pin arrangement L pin arrangement
A-coded A-coded
(Normal key) (Normal key)

EX600
Item Specifications Item Specifications
Cable O.D. ø6 mm Cable O.D. ø6 mm
Nominal cross section 0.3 mm2/AWG22 Nominal cross section 0.3 mm2/AWG22
Wire diameter Wire diameter
1.5 mm 1.5 mm
(Including insulator) (Including insulator)

EX245
Type 3
Min. bending radius 40 mm (Fixed) Min. bending radius 40 mm (Fixed)

Cable core
Terminal no. wire colors
1 Brown
2 White

EX250
3 Blue
4 Black
5 Gray

Connections

EX120/121/122
SPEEDCON

PCA-  1401804 PCA- 1557769


Cable length (L) Cable length (L)

EX140
1401804 1557769

Type 1
1500 mm 3000 mm
1401805 3000 mm
1401806 5000 mm
ø14.8

ø14.8

ø14.8

L
EX180
44.5 50 44 L 46.8
5 1 2
ø5

ø4.7

4 3
M12 M12 M12
Socket connector SPEEDCON SPEEDCON SPEEDCON
EX510

pin arrangement
Type 2

Terminal Terminal
A-coded 1 2 no. no. 2 1
Item Specifications 1 1
(Normal key) 2 2
Cable O.D. ø5 mm 3 3
Nominal cross section 0.3 mm2/AWG22 4 4
4 3 3 4
Wire diameter Connections
1.27 mm Socket connector Plug connector
M8/M12

(Including insulator)
pin arrangement pin arrangement
Min. bending radius 21.7 mm (Fixed)
A-coded A-coded
(Normal key) (Normal key)
Cable core
Terminal no. wire colors
1 Brown
2 White
ATEX

3 Blue
4 Black
5 Green/Yellow

Connections
123-1 A
EX600 Series

!1 Communication Cable
44.5 5000 50
For CC-Link 22.5
∗1 1 2

ø14.8
PCA-1567720
(Socket) 4 3

ø7.7
Marker tag Marker tag Shield
Socket connector pin arrangement M12
A-coded (Normal key) SPEEDCON
∗1 Number of holes: 5,
Total number of pins: 4 47.3 5000 50
22.5
2 1

ø14.8
PCA-1567717
(Plug) 3 4

ø7.7
Marker tag Marker tag Shield
Plug connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Terminal no. Core wire
Cable O.D. ø7.7 mm
color
1 : SLD
Conductor nominal Data pair 0.5 mm2/AWG20
2 White: DB cross section
3 Yellow: DG Drain 0.34 mm2/AWG22
Made to Order 4 Blue: DA
Wire O.D. (Including insulator) 2.55 mm
Cable length 10000 mm p. 130 Connections Min. bending radius (Fixed) 77 mm

EX9-AC  005  MJ-SSPS (With connector on both sides (Socket/Plug))


44.5 L 47.3
ø14.8

ø14.8
Cable length Metal parts 22.5 Metal parts
005 500 mm
010 1000 mm
020 2000 mm
ø7.7

030 3000 mm M12 Marker tag Marker tag M12


050 5000 mm SPEEDCON SPEEDCON
100 10000 mm
1 2 Core wire Signal name 2 1
∗1 Terminal no. Terminal no. color CC-Link
4 4 Blue DA
2 2 White DB
3 3 Yellow DG
Item Specifications 4 3 1 1 Shield SLD 3 4
Cable O.D. ø7.7 mm
Socket connector Metal parts Shield Metal parts Plug connector
Conductor nominal Data pair 0.5 mm2/AWG20
cross section pin arrangement pin arrangement
Drain 0.34 mm2/AWG22 Connections
A-coded (Normal key) A-coded (Normal key)
Wire O.D. (Including insulator) 2.55 mm
∗1 Number of holes: 5,
Min. bending radius (Fixed) 77 mm
Total number of pins: 4

EX9-AC  005  MJ-SAPA (With angle connector on both sides (Socket/Plug))


35 L 35
33.1 33.1
22.5
Cable length
005 500 mm
29.6
32.5

010 1000 mm
ø7.7

Marker tag Marker tag


020 2000 mm

030 3000 mm ø14.8 Metal parts Metal parts ø14.4


050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON

1 Core wire Signal name ∗1 1


Terminal no. Terminal no. color CC-Link
4 4 Blue DA
2 4 2 2 White DB 4 2
Item Specifications 3 3 Yellow DG
1 1 Shield SLD
Cable O.D. ø7.7 mm 3 3
Conductor nominal Data pair 0.5 mm2/AWG20 Plug connector Metal parts Shield Metal parts Socket connector
cross section Drain 0.34 mm2/AWG22 pin arrangement pin arrangement
Wire O.D. (Including insulator) 2.55 mm
Connections
A-coded (Normal key) A-coded (Normal key)
Min. bending radius (Fixed) 77 mm ∗1 Number of holes: 5,
Total number of pins: 4

A 124
Accessories EX600 Series

!1 Communication Cable
44.5 5000 50
For DeviceNet™ 22.5
5 1 2

ø14.8
PCA-1557633
(Socket) 4 3

EX260
ø6.7
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) 47.3 5000 50

Type 1
22.5

EX123/124/126
5 2 1

ø14.8
PCA-1557646
(Plug) 3 4

ø6.7
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Terminal no. Core wire Cable O.D. ø6.7 mm

EX500
Type 2
color
1 : DRAIN Conductor nominal Power pair 0.34 mm2/AWG22
2 Red: V+
3 Black: V- cross section Data pair 0.25 mm2/AWG24
4 White: CAN H
5 Blue: CAN L Wire O.D. Power pair 1.4 mm
Made to Order (Including insulator) Data pair 2.05 mm
Connections
Cable length 10000 mm p. 130 Min. bending radius (Fixed) 67 mm

EX600
EX9-AC  005  DN-SSPS (With connector on both sides (Socket/Plug))
44.5 L 47.3
ø14.8

ø14.8
Cable length (L) Metal parts 22.5 Metal parts

EX245
Type 3
005 500 mm
010 1000 mm
020 2000 mm
ø6.7

030 3000 mm M12 Marker tag Marker tag M12


050 5000 mm SPEEDCON SPEEDCON

EX250
100 10000 mm
Core wire Signal name
Terminal no. Terminal no. color DeviceNetTM
1 2 2 1
Item Specifications 1 1 Shield DRAIN
Cable O.D. ø6.7 mm 5 2 2 Red V+ 5
3 3 Black V–
Conductor nominal Power pair 0.34 mm2/AWG22 4 4 White CAN H

EX120/121/122
cross section Data pair 0.25 mm2/AWG24 4 3 5 5 Blue CAN L
3 4
Wire O.D. Power pair 1.4 mm Metal parts Shield Metal parts
(Including insulator) Data pair 2.05 mm Socket connector Plug connector
Min. bending radius (Fixed) 67 mm pin arrangement Connections pin arrangement
A-coded (Normal key) A-coded (Normal key)

EX140
EX9-AC  005  DN-SAPA (With angle connector on both sides (Socket/Plug))
Type 1
36.3 L 36.3
22.5
Cable length (L)
005 500 mm
EX180
27.5

010 1000 mm
30

ø6.7

020 2000 mm
Metal parts
Marker tag Marker tag
030 3000 mm Metal parts
050 5000 mm ø14.8 M12 M12 ø14.8
100 10000 mm SPEEDCON SPEEDCON
EX510
Type 2

1 Core wire Signal name 1


5 Terminal no. Terminal no. color DeviceNetTM 5
Item Specifications 2 4 1 1 Shield DRAIN 4 2
M8/M12

2 2 Red V+
Cable O.D. ø6.7 mm 3 3 Black V–
Conductor nominal Power pair 0.34 mm2/AWG22 3 4 4 White CAN H 3
cross section Data pair 0.25 mm2/AWG24 5 5 Blue CAN L
Plug connector Socket connector
Wire O.D. Power pair 1.4 mm pin arrangement Metal parts Shield Metal parts pin arrangement
(Including insulator) Data pair 2.05 mm A-coded (Normal key)
A-coded (Normal key)
Min. bending radius (Fixed) 67 mm Connections
ATEX

124-1 A
EX600 Series

!1 Communication Cable
44.5 5000 50
For PROFIBUS DP 22.5
5 1 2

ø14.8
PCA-1557688
(Socket) 4 3

ø7.8
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
47.3 5000 50
22.5
5 2 1

ø14.8
PCA-1557691
(Plug) 3 4

ø7.8
Marker tag Marker tag
Plug connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
Terminal no. Core wire
color Item Specifications
2
1
Green: A Line
:− Cable O.D. ø7.8 mm
3 :−
4
5
Red: B Line
:−
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 2.55 mm
Shield line is connected to the knurl.
Min. bending radius (Fixed) 78 mm
Connections

For EtherCAT For PROFINET For EtherNet/IP™


EX9-AC  020  EN-PSRJ (Plug/RJ-45 connector)
ø14.8

Cable length (L) M12 Metal parts Metal parts RJ-45


ø6.4

010 1000 mm
020 2000 mm
030 3000 mm 47.3 L 44
050 5000 mm
100 10000 mm Terminal Terminal Core wire 1
2 1 Signal name no. no. color 2
3
TD+ 1 1 White/Orange 4
Orange 5
RD+ 2 2 6
3 4 TD− 3 3 White/Green 7
8
4 4
Plug connector RD− 5 Plug connector
Green
pin arrangement Metal parts 6 pin arrangement
7
D-coded 8

Shield Metal parts

Connections Item Specifications


(Straight cable) Cable O.D. ø6.4 mm
Conductor nominal cross section 0.14 mm2/AWG26
Wire O.D. (Including insulator) 0.98 mm
Min. bending radius (Fixed) 26 mm

PCA-1446566 (Plug)
ø14.8

47.3 5000 50
2 1

3 4
ø6.5

Plug connector M12


pin arrangement SPEEDCON
Wire guide
D-coded Terminal no. color

1 Yellow: TD+
2 White: RD+
3 Orange: TD−
4 Blue: RD−

Connections

Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section AWG22
Made to Order Wire O.D. (Including insulator) 1.55 mm
Change in the cable length p. 131 Min. bending radius (Fixed) 45.5 mm
A 125
Accessories EX600 Series

!1 Communication Cable

For EtherCAT® For PROFINET For EtherNet/IP™


EX9-AC  005  EN-PSPS (With connector on both sides (Plug/Plug))

EX260
ø14.8

ø14.8
Cable length (L) 47.3 L 47.3

005 500 mm

Type 1
010 1000 mm
020

EX123/124/126
2000 mm

ø6.5
030 3000 mm Metal parts Metal parts
050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON

2 1 Terminal Terminal Core wire Signal 2 1


no. no. color name
1 1 Yellow TD+

EX500
RD+

Type 2
2 2 White
3 4 3 3 Orange TD– 3 4
Blue RD–
4 4
Plug connector Plug connector
pin arrangement Metal parts Shield Metal parts pin arrangement
D-coded D-coded
Connections (Straight cable)

EX600
Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm

EX245
Type 3
EX9-AC  005  EN-PAPA (With angle connector on both sides (Plug/Plug))
36.3 L

EX250
Cable length (L)
005 500 mm
010 1000 mm
30.8

ø6.5

020 2000 mm
Metal parts Metal parts
030 3000 mm

EX120/121/122
050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON
ø15

EX140
1 Terminal Terminal Core wire Signal 3

Type 1
no. no. color name
2 4 1 1 Yellow TD+ 4 2
2 2 White RD+
Orange TD–
3 3 3
Blue RD– 1
4 4
Plug connector Plug connector
Metal parts Shield Metal parts
EX180
pin arrangement pin arrangement
D-coded D-coded
Connections (Straight cable)

Item Specifications
Cable O.D. ø6.5 mm
EX510
Type 2

Conductor nominal cross section 0.34 mm2/AWG22


Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm
M8/M12
ATEX

125-1 A
Accessories EX600 Series

!2 Field-wireable Communication Connector


Plug
≈ 60
For CC-Link For DeviceNet™

EX260
PCA-1557617 PCA-1557659

ø19

ø17
A-coded M12 Width across flats 16

Type 1
(Normal key)

EX123/124/126
≈ 60
For PROFIBUS DP Applicable Cable
PCA-1557701 Item Specifications

ø19

ø17
Cable O.D. 4.0 to 8.0 mm
B-coded M12 Width across flats 16 Wire gauge (Stranded 0.14 to 0.5 mm2
(Reverse key) wire cross section) AWG26 to 20

EX500
Type 2
For EtherCAT For PROFINET For EtherNet/IP™
PCA-1446553 ≈ 61

ø17.5

EX600
ø19

D-coded M12 Width across flats 16 Width across flats 13

EX245
Type 3
Applicable Cable
Item Specifications
Cable O.D. 4.0 to 8.0 mm

EX250
Wire gauge (Stranded wire cross section) 0.14 to 0.34 mm2/AWG26 to 22
* T
 he table above shows the specifications for the applicable cable. Adaptation for the
connector may vary on account of the conductor construction of the electric wire.

EX120/121/122
Socket
≈ 58
For CC-Link For DeviceNet™
PCA-1557620 PCA-1557662
ø19

ø17

EX140
Type 1
A-coded M12 Width across flats 16
(Normal key)

≈ 58
For PROFIBUS DP Applicable Cable EX180
ø19

ø17

Item Specifications
PCA-1557714 Cable O.D. 4.0 to 8.0 mm
B-coded M12 Width across flats 16 Wire gauge (Stranded 0.14 to 0.5 mm2
(Reverse key) wire cross section) AWG26 to 20
EX510
Type 2

M8/M12
ATEX

126 A
EX600 Series

!3 I/O Cable with Connector /I/O Connector


For details, refer to pages 237 to 239 and later.
Name Use Part no. Description

Cable with For sensor PCA-1557769 Cable with M12 connector (4 pins/3 m)
connector
PCA-1557772 Cable with M8 connector (3 pins/3 m)

PCA-1557730 Field-wireable connector (M8/3 pins/Plug/Piercecon® connection)


Field-wireable
connector
For sensor PCA-1557743 Field-wireable connector
(M12/4 pins/Plug/QUICKON-ONE connection/SPEEDCON)
PCA-1557756
PCA-1557785 Y connector (2 x M12 (5 pins)-M12 (5 pins)/SPEEDCON)
Y connector For sensor
PCA-1557798 Y connector (2 x M8 (3 pins)-M12 (4 pins)/SPEEDCON)

* When using the Y connector, connect it to the connector on the I/O unit through the sensor cable (PCA-1557769) with the M12 connector.

M12 M12
x2

M12

M8/M12 connector

M8 M12
x2

Y connector Cable with connector I/O unit

A 127
EX600 Series
Made to Order
Please contact SMC for detailed specifications and lead times.

SI Unit Prepare the SI unit, each type of unit, and the manifold valve (without SI unit) separately, and combine them before use.

q MRP (PROFINET) compatible w Ethernet POWERLINK compatible

EX260
EX600-SPN1A-X34 EX600-SPL1-X26
¡Dimensions are the same as those of the EX600-SPN1. ¡Dimensions are the same as those of the EX600-SEN3.

Type 1

EX123/124/126
EX500
Type 2

EX600
EX245
Type 3

EX250
EX120/121/122
EX140
Type 1

EX180
EX510
Type 2

M8/M12
ATEX

128 B
Made to Order EX600 Series

Communication Cable
e With connector on one side (Socket) For CC-Link
Cable length: 10000 mm
Dimensions
For CC-Link For DeviceNet™

EX260
44.5 10000 50

ø14.8
EX9-AC100  MJ  -X12 22.5

Type 1
Applicable protocol

EX123/124/126
ø7.7
Marker tag Marker tag Shield
MJ CC-Link
DN DeviceNet™ M12
SPEEDCON
2 ∗1 Connections
Terminal no. Core wire color: Signal name (CC-Link) Item Specifications
1 3 1 Shield: SLD Cable O.D. ø7.7 mm

EX500
2 White: DB Conductor nominal Data pair 0.5 mm2/AWG20

Type 2
4 3 Yellow: DG cross section Drain 0.34 mm2/AWG22
Socket connector 4 Blue: DA Wire O.D. (Including insulator) 2.55 mm
pin arrangement *1 Number of holes: 5, Total number of Min. bending radius (Fixed) 77 mm
A-coded (Normal key) pins: 4

EX600
For DeviceNet™
Dimensions

EX245
44.5 10000 50

Type 3
ø14.8

22.5
ø6.7

Marker tag Marker tag

EX250
M12
SPEEDCON
2 Connections
5
Terminal no. Core wire color: Signal name (DeviceNetTM) Item Specifications
1 3 1 Shield: DRAIN Cable O.D. ø6.7 mm

EX120/121/122
2 Red: V+ Conductor nominal Power pair 0.34 mm2/AWG22
4 3 Black: V− cross section Data pair 0.25 mm2/AWG24
Socket connector 4 White: CAN H Wire O.D. Power pair 1.4 mm
pin arrangement 5 Blue: CAN L (Including insulator) Data pair 2.05 mm
A-coded (Normal key) Min. bending radius (Fixed) 67 mm

EX140
Type 1

EX180
EX510
Type 2

M8/M12
ATEX

130 A
EX600 Series
Specific Product Precautions
Be sure to read this before handling the products. Refer to page 277 for safety
instructions. For fieldbus system precautions, refer to pages 278 to 280 and the
“Operation Manual” on the SMC website: http://www.smcworld.com

Mounting Adjustment / Operation

EX260
Caution Warning
1. When handling and assembling units, do not touch <Handheld Terminal>

Type 1
the sharp metal parts of the connector or plug. 1. Do not apply pressure to the LCD.

EX123/124/126
2. When connecting six stations or more, be sure to There is a possibility of the crack of LCD and injuring.
use the intermediate reinforcing brace (EX600-ZMB1 2. The forced input/output function is used to change
or EX600-ZMB2). the signal status forcibly. When operating this
function, be sure to check the safety of the
surroundings and installation.

EX500
Operating Environment

Type 2
This may cause, injuries or equipment damage.

Caution 3. Incorrect setting of parameters can cause a


malfunction. Be sure to check the settings before
1. Select the proper type of enclosure according to the
use.

EX600
operating environment.
This may cause injuries or equipment damage.
IP65/67 is achieved when the following conditions are met.
1) Provide appropriate wiring between all units using electrical
wiring cables, communication connectors and cables with Caution
M12 connectors.

EX245
<Handheld Terminal>

Type 3
2) Appropriately mount each unit and valve manifold.
3) Be sure to mount a seal cap on any unused connectors.
1. D
 o not press the setting buttons with a sharp pointed
If using in an environment that is exposed to water splashes,
object.
please take measures such as using a cover. This may cause damage or equipment failure.

EX250
When the enclosure is IP40, do not use in an operating 2. Do not apply excessive load and impact to the setting
environment or atmosphere where it may come in contact with buttons.
corrosive gas, chemical agents, seawater, water, or water vapor. This may cause damage, equipment failure or malfunction.
When connected to the EX600-DmmE or EX600-DmmF,
manifold enclosure is IP40. When the order does not include the SI unit, a valve plate which

EX120/121/122
Also, the handheld terminal conforms to IP20, so prevent connects the manifold and SI unit, is not mounted. Use attached
valve holding screws and mount the valve plate.
foreign matter from entering inside, and water, solvent or oil
(Tightening torque: 0.6 to 0.7 N·m)
from coming in direct contact with it. Screw tightened parts
SV series: 2 places
S0700 series: 2 places

EX140
VQC1000 series: 2 places

Type 1
VQC2000 series: 3 places
VQC4000 series: 4 places
SY series: 2 places
Valve holding screw EX180

Valve plate
EX510
Type 2

M8/M12

 Trademark
DeviceNet™ is a trademark of ODVA.
ATEX

EtherNet/IP™ is a trademark of ODVA.


EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Modbus® is a registered trademark of Schneider Electric, Iicensed to the Modbus Organization, Inc.
QuickConnect™ is a trademark of ODVA.
132
P.G. information
Contact our sales office for delivery dates Point to Group
and prices as this is a special model. Specialized Product

Ethernet POWERLINK Compatible Fieldbus System


EX600-SPL1-X26

Supports the Ethernet POWERLINK communication


Features
protocol
* Ethernet POWERLINK: Industrial Ethernet that supports a communication speed of 100 Mbps

Analog Unit SI Unit


M12 connector (5 pins) Input device

Input
unit
2CH
Output
unit
2CH Pressure IP67
sensor Flow sensor
Input/Output 2CH/
unit 2CH Output device

Handheld Terminal

IP67 IP67 Electro-pneumatic regulator, etc.

Input Input Input Output Input/Output Input Input/Output


unit unit unit unit unit unit unit
Units can be
differentiated
by color.

Power
supply

End
plate Digital unit Analog unit SI unit

For detailed specifications of connectable devices, refer to the catalog of each device and select the right device
for your application. If anything is unclear, please contact SMC.

Digital Unit
Input device
M12 connector (5 pins) M8 connector (3 pins) D-sub connector Spring type terminal block Pressure Flow switch
Input switch
unit 8 inputs 16 inputs 8 inputs 16 inputs 16 inputs

Output Auto switch Others


unit 8 outputs 16 outputs 16 outputs Proximity sensor
Photoelectric switch
Input/Output Limit switch
8 inputs/ 8 inputs/
unit 8 outputs 8 outputs

Output device
Solenoid valve Others
Indicator light
Relay
IP67 IP67 IP67 IP40 IP40 Buzzer

Manifold Solenoid Valves


SY3000/5000/7000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000/5000 Series

IP67 IP67 IP40 IP67

To ensure the safest possible operation of this product, please be sure to thoroughly read the
Caution “Safety Instructions” in our “Best Pneumatics” catalog before use.

4-14-1, SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com SP175X-026E


©2018 SMC Corporation All Rights Reserved P: WS
Ethernet POWERLINK Compatible Fieldbus System
P.G. information
Point to Group
Specialized Product
EX600-SPL1-X26

Specifications

Item Specifications
Protocol Ethernet POWERLINK
Media 100BASE-TX
Communication
Communication speed 100 Mbps, Half duplex
Node ID setting range 1 to 239
Internal current consumption (Power supply for control/input) 120 mA or less
Output type Source/PNP (Negative common)
Number of outputs 32 points
Solenoid valve with surge voltage suppressor of 24 VDC and 1.0 W or less
Connected load
Output (made by SMC)
Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR/Forced power ON
Protection Short-circuit protection
Enclosure IP67 (Manifold assembly)
Standards CE marking, UL (CSA), RoHS compliant
Weight 300 g or less
Please contact SMC for the operation manual and configuration file.
Refer to the catalog and the SMC website for other specifications of the EX600, end plate, and input/output units.

Wiring Specifications
Communication connector BUS IN/OUT

M12 4-pin socket, D-Coding

No. Designation Mating cable examples [M12 connector (straight) — Separate lines]
: PCA-1446566 (5 m) made by SMC, etc.
1 TX+
2 RX+ [M12 connector (straight) (Fieldwireable connector)]
3 TX− : PCA-1446553 made by SMC, etc.
4 RX−
[M12 connector (straight) — RJ45 connector]
: EX9-AC010EN-PSRJ (1 m)
: EX9-AC020EN-PSRJ (2 m)
: EX9-AC030EN-PSRJ (3 m)
: EX9-AC050EN-PSRJ (5 m)
: EX9-AC100EN-PSRJ (10 m)
(made by SMC), etc.

[M12 connector (straight) — M12 connector (straight)]


: EX9-AC010EN-PSPS-X19 (1 m)
: EX9-AC020EN-PSPS-X19 (2 m)
: EX9-AC030EN-PSPS-X19 (3 m)
: EX9-AC050EN-PSPS-X19 (5 m)
: EX9-AC100EN-PSPS-X19 (10 m)
(made by SMC), etc.

How to Order

EX600 S PL 1 X26
Communication protocol Output specification
PL Ethernet POWERLINK 1 32 outputs, PNP (Negative common)/Source

∗ Order the end plate and input/output units as a set to be used in combination.
Ethernet POWERLINK Compatible Fieldbus System
P.G. information
Point to Group
Specialized Product
EX600-SPL1-X26

Dimensions [mm]

Caution
1. For the dimensions when combined with the valve manifold, use the valve manifold dimensions of the standard EX600 series.
2. Order the valve manifold, end plate, and input/output units separately.
Specify “no SI unit” and “negative common” for the valve manifold specifications.
P.G. information
Contact our sales office for delivery dates Point to Group
and prices as this is a special model. Specialized Product

CC-Link IE Field Compatible Fieldbus System


EX600-SCF1-X60

Supports the CC-Link IE Field communication


Features
protocol
* CC-Link IE Field: Industrial Ethernet that supports a communication speed of 1 Gbps

Analog Unit
M12 connector (5 pins) Input device

Input
unit
2CH
Output
unit
2CH
Pressure sensor Flow sensor
Input/Output 2CH/
unit 2CH Output device

IP67 IP67 Electro-pneumatic regulator, etc.

Input Input Input Output Input/Output Input Input/Output


unit unit unit unit unit unit unit
Units can be
differentiated
by color.

Power
supply

End
plate Digital unit Analog unit SI unit

For detailed specifications of connectable devices, refer to the catalog of each device and select the right device
for your application. If anything is unclear, please contact SMC.

Digital Unit
Input device
M12 connector (5 pins) M8 connector (3 pins) D-sub connector Spring type terminal block Pressure Flow switch
Input switch
unit 8 inputs 16 inputs 8 inputs 16 inputs 16 inputs

Output Auto switch Others


unit 8 outputs 16 outputs 16 outputs Proximity sensor
Photoelectric switch
Input/Output Limit switch
8 inputs/ 8 inputs/
unit 8 outputs 8 outputs

Output device
Solenoid valve Others
Indicator light
Relay
IP67 IP67 IP67 IP40 IP40 Buzzer

Manifold Solenoid Valves


SY3000/5000/7000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000/5000 Series

IP67 IP67 IP40 IP67

To ensure the safest possible operation of this product, please be sure to thoroughly read the
Caution “Safety Instructions” in our “Best Pneumatics” catalog before use.

4-14-1, SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com SP175X-028E


©2018 SMC Corporation All Rights Reserved P: WR
CC-Link IE Field Compatible Fieldbus System
P.G. information
Point to Group
Specialized Product
EX600-SCF1-X60

Specifications

Item Specifications
Protocol CC-Link IE Field
Station type Intelligent device station
Communication speed 1 Gbps
Allowable station number setting 1 to 120
Allowable network number setting 1 to 239
Transmission method Cyclic transmission
Communication
Configuration file CSP+
Network topology Star, Line, Ring
RX: 32 to 176 bits
Occupied input size
RWr: 32 to 608 words
RY: 32 to 176 bits
Occupied output size
RWW: 32 to 608 words
Internal current consumption (Power supply for control/input) 140 mA or less
Output type Source/PNP (Negative common)
Number of outputs 32 outputs
Solenoid valve with surge voltage suppressor of 24 VDC and 1.0 W or less
Connected load
(made by SMC)
SY3000, SY5000, SY7000
Output VQC1000, VQC2000, VQC4000, VQC5000
Applicable valve manifold
SV1000, SV2000, SV3000
S0700
Power supply 24 VDC, 2 A
Fail safe HOLD/CLEAR
Protection Short-circuit protection
Operating temperature range −10 to 50°C
Enclosure IP67 (Manifold assembly)
Standards CE marking, RoHS compliant
Weight 300 g or less

Please contact SMC for the operation manual and configuration file.
Refer to the catalog and the SMC website for other specifications of the EX600, end plate, and input/output units.

Wiring Specifications
Communication connector PORT 1 (P1) & PORT 2 (P2)

M12 8-pin socket, X-Coding (Cat. 6A)

No. Designation Mating cable examples [M12 connector — Separate lines]


1 DA+ : NBC-MSX/1,0-94F SCO (Order no.: 1407467) (1 m)
: NBC-MSX/2,0-94F SCO (Order no.: 1407468) (2 m)
2 DA− : NBC-MSX/5,0-94F SCO (Order no.: 1407469) (5 m), etc.
3 DB+ (made by PHOENIX CONTACT)
4 DB−
[M12 connector — RJ45 connector]
5 DD+
: NBC-MSX/1,0-94F/R4AC SCO (Order no.: 1407471) (1 m)
6 DD− : NBC-MSX/2,0-94F/R4AC SCO (Order no.: 1407472) (2 m)
7 DC− : NBC-MSX/5,0-94F/R4AC SCO (Order no.: 1407473) (5 m), etc.
8 DC+ (made by PHOENIX CONTACT)

How to Order

EX600 S CF 1 X60
Communication protocol Output specification
CF CC-Link IE Field 1 32 outputs, PNP (Negative common)/Source

* Order the end plate and input/output units as a set to be used in combination.
CC-Link IE Field Compatible Fieldbus System
P.G. information
Point to Group
Specialized Product
EX600-SCF1-X60

Dimensions [mm]

Marker
PORT-2 connector for CC-Link IE Field groove PORT-1 connector for CC-Link IE Field

MAC address

Caution
1. F
 or the dimensions when combined with the valve manifold, use the valve manifold dimensions of the standard
EX600 series.
2. Order the valve manifold, end plate, and input/output units separately.
Specify “no SI unit” and “negative common” for the valve manifold specifications.
MODBUS TCP Compatible
Fieldbus System
Supports MODBUS TCP Communication

EX600-SMT1-X25
Analog Unit SI Unit
M12 connector (5 pins) Input device

Input
unit
2CH
Output
unit
2CH Pressure IP67
sensor Flow sensor
Input/Output 2CH/
unit 2CH Output device

Handheld Terminal

IP67 IP67 Electro-pneumatic regulator, etc.

Input Input Input Output Input/Output Input Input/Output


unit unit unit unit unit unit unit
Units can be
differentiated
by color.

Power
supply

End
plate Digital unit Analog unit SI unit

For detailed specifications of connectable devices, refer to the catalog of each device and select the right device
for your application. If anything is unclear, please contact SMC.

Digital Unit
Input device
M12 connector (5 pins) M8 connector (3 pins) D-sub connector Spring type terminal block Pressure Flow switch
Input switch
unit 8 inputs 16 inputs 8 inputs 16 inputs 16 inputs

Output Auto switch Others


unit 8 outputs 16 outputs 16 outputs Proximity sensor
Photoelectric switch
Input/Output Limit switch
8 inputs/ 8 inputs/
unit 8 outputs 8 outputs

Output device
Solenoid valve Others
Indicator light
Relay
IP67 IP67 IP67 IP40 IP40 Buzzer

Manifold Solenoid Valves


SY3000/5000/7000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000/5000 Series

IP67 IP67 IP40 IP67

Caution
To ensure the safest possible operation of this product, please be sure to thoroughly read the
“Safety Instructions” in our “Best Pneumatics” catalog before use.

NPDF383-A
MODBUS Compatible Fieldbus System
EX600-SMT1-X25

Wiring Specifications
Communication connector BUS IN/OUT

M12 4-pin socket, D-Coding Mating cable examples [M12 connector (straight) — Separate lines]
: PCA-1446566 (5 m) made by SMC, etc.
No. Designation
[M12 connector (straight) (Fieldwireable connector)]
1 TX+
: PCA-1446553 made by SMC, etc.
2 RX+
3 TX− [M12 connector (straight) — RJ45 connector]
: EX9-AC010EN-PSRJ (1 m)
4 RX− : EX9-AC020EN-PSRJ (2 m)
: EX9-AC030EN-PSRJ (3 m)
: EX9-AC050EN-PSRJ (5 m)
: EX9-AC100EN-PSRJ (10 m)
(made by SMC), etc.

[M12 connector (straight) — M12 connector (straight)]


: EX9-AC010EN-PSPS-X19 (1 m)
: EX9-AC020EN-PSPS-X19 (2 m)
: EX9-AC030EN-PSPS-X19 (3 m)
: EX9-AC050EN-PSPS-X19 (5 m)
: EX9-AC100EN-PSPS-X19 (10 m)
(made by SMC), etc.

How to Order

EX600 S MT1 X25


Communication protocol Output specification
PL MODBUS TCP 1 32 outputs, PNP (Negative common)/Source

∗ Order the end plate and input/output units as a set to be used in combination.
MODBUS TCP Compatible Fieldbus System
EX600-SMT1-X25

Dimensions [mm]

Caution
1. For the dimensions when combined with the valve manifold, use the valve manifold dimensions of the standard EX600 series.
2. Order the valve manifold, end plate, and input/output units separately.
Specify “no SI unit” and “negative common” for the valve manifold specifications.
Global Manufacturing, Distribution and Service Network
Worldwide Subsidiaries
EUROPE ASIA / OCEANIA
AUSTRIA LATVIA AUSTRALIA VIETNAM
SMC Pneumatik GmbH (Austria) SMC Pneumatics Latvia SIA SMC Pneumatics (Australia) Pty. Ltd. SMC Pneumatics (VN) Co., Ltd
BELGIUM LITHUANIA CHINA
SMC Pneumatics N.V./S.A. UAB “SMC Pneumatics” SMC (China) Co., Ltd. AFRICA
BULGARIA NETHERLANDS SMC Pneumatics (Guangzhou) Ltd.
SOUTH AFRICA
SMC Industrial Automation Bulgaria EOOD SMC Pneumatics B.V. HONG KONG SMC Pneumatics (South Africa) Pty Ltd
CROATIA NORWAY SMC Pneumatics (Hong kong) Ltd.
SMC Pneumatics Norway AS INDIA
SMC Industrijska Automatika d.o.o.
SMC Pneumatics (India) Pvt. Ltd.
NORTH, CENTRAL &
CZECH REPUBLIC POLAND
SMC Industrial Automation CZ s.r.o. SMC Industrial Automation Polska Sp. z o.o. INDONESIA SOUTH AMERICA
DENMARK ROMANIA PT. SMC Pneumatics Indonesia ARGENTINA
SMC Pneumatik A/S SMC Romania S.r.l. JAPAN SMC Argentina S.A.
ESTONIA RUSSIA SMC Corporation BOLIVIA
SMC Pneumatics Estonia SMC Pneumatik LLC. MALAYSIA SMC Pneumatics Bolivia S.R.L.
FINLAND SLOVAKIA SMC Pneumatics (S.E.A.) Sdn. Bhd. BRAZIL
SMC Pneumatics Finland OY SMC Priemyselná Automatizácia, Spol s.r.o. NEW ZEALAND SMC Pneumáticos do Brasil Ltda.
FRANCE SLOVENIA SMC Pneumatics (N.Z.) Ltd. CANADA
SMC Pneumatique S.A. SMC Industrijska Avtomatika d.o.o. PHILIPPINES SMC Pneumatics (Canada) Ltd.
GERMANY SPAIN / PORTUGAL Shoketsu SMC Corporation CHILE
SMC Pneumatik GmbH SMC España, S.A. SINGAPORE SMC Pneumatics (Chile) S.A.
GREECE SWEDEN SMC Pneumatics (S.E.A.) Pte. Ltd. COLOMBIA
SMC Hellas EPE SMC Pneumatics Sweden AB SOUTH KOREA SMC Colombia Sucursal de SMC Chile, S.A.
HUNGARY SWITZERLAND SMC Pneumatics Korea Co., Ltd. MEXICO
SMC Hungary Ipari Automatizálási Kft. SMC Pneumatik AG TAIWAN SMC Corporation (Mexico) S.A. de C.V.
IRELAND TURKEY SMC Pneumatics (Taiwan) Co., Ltd. PERU
SMC Pneumatics (Ireland) Ltd. SMC Pnömatik Sanayi Ticaret ve Servis A.Ş. THAILAND SMC Corporation Peru S.A.C.
ITALY UK SMC (Thailand) Ltd. USA
SMC Italia S.p.A. SMC Pneumatics (U.K.) Ltd. UNITED ARAB EMIRATES SMC Corporation of America
KAZAKHSTAN SMC Pneumatics Middle East FZE VENEZUELA
LLP “SMC Kazakhstan” SMC Neumatica Venezuela S.A.

U.S. & Canadian Sales Offices


WEST EAST
Austin Albany
Dallas Atlanta
Los Angeles Birmingham
Phoenix Boston
Portland Charlotte
San Jose Knoxville
Nashville
CENTRAL Toronto
New Jersey
Chicago
Rochester
Cincinnati
Tampa
Cleveland
Detroit CANADA
Indianapolis
Des Moines Montreal
Grand Rapids Quebec City
Indianapolis Toronto
Kansas City Vancouver Sales Branches
Milwaukee Windsor Regional Distribution Centers
Minneapolis Central warehouse
St. Louis

SMC Corporation of America


10100 SMC Blvd., Noblesville, IN 46060
www.smcusa.com
SMC Automation Canada Ltd.
www.smcautomation.ca
(800) SMC.SMC1 (762-7621)
e-mail: sales@smcusa.com
International Inquiries: www.smcworld.com
© 2020 SMC Corporation of America, All Rights Reserved.
All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.
However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.
Y P - PDF