Академический Документы
Профессиональный Документы
Культура Документы
Data Sheet
IPmux-2L
TDM Pseudowire Gateway
solution for Built on TDMoIP technology, implementing IETF, MFA Forum, ITU-T for
Pseudowire Emulation Edge-to-Edge (PWE3)
transmitting E1 E1 and serial traffic emulation over MPLS, IP and Ethernet networks
Transmission of both framed (full or fractional) and unframed E1 traffic
streams over packet
switched networks IPmux-2L is a TDM pseudowire access These packets are transmitted via the
gateway extending TDM-based services IPmux-2L Ethernet network port to the
over packet switched networks. It also PSN. A remote pseudowire device converts
serves as an Ethernet-based access the packets back to TDM traffic.
device. The ASIC-based architecture provides a
PSEUDOWIRE PERFORMANCE robust and high performance pseudowire
solution with minimal processing delay.
The unit provides a legacy over PSN
solution for transmitting E1 streams over The unit employs various legacy over
packet switched networks (PSNs). The packet protocols, including TDMoIP,
device converts the data stream from its CESoPSN, SAToP and HDLCoPSN.
user E1 and high-speed data ports into
packets for transmission over the
network. The addressing scheme of these
packets is IP or MPLS.
Management traffic can run over a LAN and IP layer network condition
dedicated VLAN. statistics, such as packet loss and packet
delay variation (jitter), are monitored and
Software can be downloaded via a local stored by the device.
terminal using XMODEM/YMODEM, or
remotely, using TFTP. After downloading a Fault isolation, statistics and event logging
new software version, IPmux-2L are also available.
automatically saves the previous version in RAD’s TDM PW OAM verifies connectivity
non-volatile memory for backup purposes. and prevents pseudowire configuration
Also, copies of the configuration file may mismatch.
be downloaded and uploaded to a remote
workstation for backup and restore DYING GASP
Carrier-grade voice purposes. AC-powered units report power failures to
Current date and time are retrieved from a defined network management stations by
quality without dedicated server, using SNTP. sending a trap, thus enabling the devices
to properly disconnect from the network
compression, or DIAGNOSTICS with notification of the reason for the
External and internal loopbacks check TDM service problem.
silence suppression and serial link connectivity.
A built-in internal and external BERT utility
is used to monitor the TDM link quality.
Virtual Cable Test (VCT) checks the quality
of Ethernet cables, connectors and
terminations, identifying a cable break or
short.
V.35, V.35,
V.36, V.36,
RS-232, RS-232,
RS-530, RS-530,
X.21 X.21
FE
FCD-E1E E1 IPmux-2L
Router Legacy Device
with Serial
Interface
SDH/ N x E1
PSN
V.35, SONET V.35,
V.36, IPmux-216, IPmux-16L V.36,
RS-232, or IPmux-155L RS-232,
ADM ADM
RS-530, RS-530,
X.21 E1
X.21
FE
FCD-E1E IPmux-2L
Router Legacy Device
with Serial
Interface
Connector
LC
GENERAL Indicators
Timing PWR (green) – Power status
Internal TST (yellow) – Test status
ALM (red) – Alarm status
Receive
LOC/REM (red/red) – E1 local/remote
Loopback
sync loss
Adaptive LINK/ACT (green/yellow) – Ethernet
Adaptive Clock Characteristics link/activity status on RJ-45 or SFP
According to G.823 traffic interface Power
Sync-E AC/DC: 100–240 VAC or 48/60 VDC
Per G.8261 (no ESSM/CSM), via Ethernet nominal (40 to 72 VDC)
port 3 (ordering option, see Ordering Power Consumption
below) 8W max
Management Physical
SNMPv1v2c Height: 43 mm (1.7 in)
Telnet Width: 217 mm (8.5 in)
Depth: 170 mm (6.7 in)
ASCII terminal via V.24 (RS-232) DCE port
Weight: 0.5 kg (1.1 lb)
Web browser
Environment
Entity MIB (RFC 4133) Temperature: 0 to 50C (32 to 122F)
Dying Gasp Humidity: Up to 90%, non-condensing
AC-powered units only (ordering option,
see Ordering below)
Diagnostics
Loopbacks: E1 port local/remote, serial
port local/remote
BERT: E1 port internal/external
VCT: Ethernet ports
Statistics
E1 (per G.826 and RFC 2495)
Ethernet (per RFC 2819)
Jitter buffer indication (overflow,
underflow, sequence error, max/min jitter
buffer levels)
Data Sheet
IPmux-2L
TDM Pseudowire Gateway
and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
517-100-03/12 (2.0) Specifications are subject to change without prior notice. 1997–2012 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven,
OPTIONAL ACCESSORIES
Ordering +1 Fast Ethernet interface (in addition to
two 10/100BaseT UTP ports) The following cables convert the
STANDARD CONFIGURATIONS IPmux-2L 25-pin serial data port connector
N SFP-ready slot
IPMUX-2L/1E1 into the respective interface. Cable length
1 Fast Ethernet, 1310 nm,
IPMUX-2L/1E1/N is 2m (6 ft).
multimode, LED, 2 km
IPMUX-2L/1E1/RS232/N (1.2 mi) CBL-HS2/V/1/$
2 Fast Ethernet, 1310 nm, Adapter cable for connecting a data port
IPMUX-2L/1E1/V35
single mode, laser, 15 km in DCE timing mode to V.35 port
IPMUX-2L/1E1CX
(9.3 mi) CBL-HS2/V/2/$
IPMUX-2L/1E1CX/N 3 Fast Ethernet, 1310 nm, Adapter cable for connecting a data port
IPMUX-2L/2E1 single mode, laser, 40 km in DTE1 timing mode to V.35 port
(24.8 mi)
IPMUX-2L/2E1/N CBL-HS2/V/3/$
4 Fast Ethernet, 1310 nm,
single mode, laser, 80 km Adapter cable for connecting a data port
SPECIAL CONFIGURATIONS
(49.7 mi) in DTE2 timing mode to V.35 port
IPmux-2L/~/#/$/{/+1/ 10A Fast Ethernet, Tx - 1310 nm, CBL-HS2/R/1/$
Rx - 1550 nm, single mode Adapter cable for connecting a data port
Legend
(single fiber), laser (WDM), in DCE timing mode to V.36/RS-449 port
~ Synchronous Ethernet capability 20 km (12.4 mi) CBL-HS2/R/2/$
(leave empty for no Sync-E): 10B Fast Ethernet, Tx - 1550 nm, Adapter cable for connecting a data port
Rx - 1310 nm, single mode in DTE1 timing mode to V.36/RS-449
SYE Sync-E per G.8261
(single fiber), laser (WDM), equipment
Note: For Sync-E connection, order the third FE
20 km (12.4 mi)
port (ordering option +1 below). CBL-HS2/R/3/$
UTP 10/100BaseT
# Dying Gasp (leave empty for no Dying Notes: Adapter cable for connecting a data port
in DTE2 timing mode to V.36/RS-449 port
Gasp): The third Fast Ethernet port is optional, unless
DG Dying Gasp (AC-powered the Sync-E functionality is required.
CBL-HS2/X/1/$
units only) Adapter cable for connecting a data port
For single-fiber applications, a device with the in DCE timing mode to X.21 port
$ TDM interface (leave empty for no E1): SFP-10A interface should always work with a
1E1 1 balanced E1 Legend
device with the SFP-10B interface, and vice
1E1CX 1 unbalanced E1 versa. $ Cable connector:
2E1 2 balanced E1 F Female
2E1CX 2 unbalanced E1 SUPPLIED ACCESSORIES M Male
{ Serial interface (leave empty for no
serial interface): Power cord CBL-DB9F-DB9M-STR
AC/DC adapter plug Control port cable
V35 V.35 interface
V36 V.36/RS-449 interface Matching adapter cable if a serial interface RM-33-2
RS530 RS-530 interface Hardware kit for mounting one or two
has been ordered: IPmux-2L units into a 19-inch rack
X21 X.21 interface
CBL-HS2/V/1/F for V.35
RS232 RS-232 interface
Note: IPmux-2L must be ordered with at least one CBL-HS2/R/1/M for V.36/RS-449
user interface option: E1 or serial port. CBL-HS2/X/1/F for X.21