Вы находитесь на странице: 1из 2

22 ga 1.

5B­36 Grade 50 Roof Deck
Diaphragm Shear & Wind Uplift Interaction
with MWFRS Allowable Net Wind Uplift (ASD) of 15 psf

5/8" Visible Dia. Arc Spot Weld Connections to Supports A572 GR50 Support Member or Equivalent
36 / 5 Perpendicular Connection Pattern to Supports 0.25 ≤ Support Thickness (in.)
#10 Screw Sidelap Connections 2 in. Minimum Deck End Bearing Length

ASD Allowable Combined Wind Uplift & Diphragm Shear Strength Sn/Ω (plf) Generic 3 Span Condition
Sidelap Span
Connections
per Span 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3"
3 426 426 426 426 426 426 426 426 426
4 466 466 466 466 466 466 466 466 466
5 503 503 503 503 503 503 503 503 503
6 538 538 538 538 538 538 538 538 538
7 572 572 572 572 572 572 572 572 572
8 605 605 605 605 605 605 605 605 605
9 637 637 637 637 637 637 637 637 637

Average Connection Spacing to Supports at Parallel Chords & Collectors (in.)
Sidelap Span
Connections
per Span 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3"
3 19 19 19 19 19 19 19 19 19
4 19 19 19 19 19 19 19 19 19
5 19 19 19 19 19 19 19 19 19
6 19 19 19 19 19 19 19 19 19
7 19 19 19 19 19 19 19 19 19
8 19 19 19 19 19 19 19 19 19
9 19 19 19 19 19 19 19 19 19

Page 1 of 2
22 ga 1.5B­36 Grade 50 Roof Deck
Seismic Diaphragm Shear

5/8" Visible Dia. Arc Spot Weld Connections to Supports A572 GR50 Support Member or Equivalent
36 / 5 Perpendicular Connection Pattern to Supports 0.25 ≤ Support Thickness (in.)
#10 Screw Sidelap Connections 2 in. Minimum Deck End Bearing Length

Seismic or Wind Diaphragm Shear Stiffness, G' (kip/in.) Generic 3 Span Condition
Sidelap Span
Connections
per Span 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3"
3 22 22 22 22 22 22 22 22 22
4 22 22 22 22 22 22 22 22 22
5 23 23 23 23 23 23 23 23 23
6 23 23 23 23 23 23 23 23 23
7 23 23 23 23 23 23 23 23 23
8 23 23 23 23 23 23 23 23 23
9 24 24 24 24 24 24 24 24 24

ASD Allowable Seismic Diaphragm Shear Strength Sn/Ω (plf) Generic 3 Span Condition
Sidelap Span
Connections
per Span 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3"
3 305 305 305 305 305 305 305 305 305
4 334 334 334 334 334 334 334 334 334
5 360 360 360 360 360 360 360 360 360
6 386 386 386 386 386 386 386 386 386
7 410 410 410 410 410 410 410 410 410
8 434 434 434 434 434 434 434 434 434
9 457 457 457 457 457 457 457 457 457

Average Connection Spacing to Supports at Parallel Chords & Collectors (in.)
Sidelap Span
Connections
per Span 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3" 6'‑3"
3 19 19 19 19 19 19 19 19 19
4 19 19 19 19 19 19 19 19 19
5 19 19 19 19 19 19 19 19 19
6 19 19 19 19 19 19 19 19 19
7 19 19 19 19 19 19 19 19 19
8 19 19 19 19 19 19 19 19 19
9 19 19 19 19 19 19 19 19 19

Tables generated using calculator V4.0 based on AISI S310‑16. Date: 7/16/2020

NOTICE: Design defects that could cause injury or death may result from relying on the information in this document without independent verification by a qualified professional. The information in this
document is provided “AS IS”. Nucor Corporation and its affiliates expressly disclaim: (i) any and all representations, warranties and conditions and (ii) all liability arising out of or related to this document
and the information in it.

Page 2 of 2