Jiroga Weir Scheme-Glacis

Manning's Analysis Bed Slope, S 2180 in 1


Bed Level 57.55 m
Mannings Formula Safe Exit Gradient= 0.17
v=(1/n)*R2/3S1/2 Mannings Coeff.= 0.025
Silt Factor, f 0.9
Dickens Formula
Plan DogLegged
Q=c*A3/4 Channel C/S Profile Location Av. Width Area (A) Wetted Perimeter R
Trapezium Ch. 0.00 19.50 74.1 sqm 28.81547 m 2.57153544
Afflux
61.35
Haf=(v2/17.85 + 0.0152)*((A/a)2-1)
27
60.39
18.00
3.80
BC=9.70t/m2
2.84
57.55
12 7.5

Data Sheet

U/S Bed L U/S PL at Site W.L D/S W.L D/S Bed L Bank Level V.Avg Q=A.V q=Q/T
Design 58.61 60.39 60.39 60.00 56.49 60.44 1.6080273 119.154824 4.41314
Lean 57.55
Peak 56.49 61.44 61.35 61.28

1/7
Jiroga Weir Scheme-Glacis

Top of Guide Bund

U/S TEL 62.00

= HFL
U/S 61.44 D/S TEL 61.72
Max PL 60.39 60.50 D/S WL 60.00
FSL Q= 119.154824 cumecs
Crest Level 60.11
U/S Bed L 58.61 57.66
Launching Apron CC Block
D/S Bed L 56.49

CC Block Launching Apron

55.18
89

Design Details
1 Fixation of crest level and waterway Formula Used:
Adopt Crest L= Bed L+ 1.5= 60.11 m Provide, 13 bays of 2 m each Q= 𝑐𝑙 2𝑔{(ℎ + ℎ𝑎) /
-ℎ𝑎 /
}
Taking, c= 0.577 c'= 0.8 Provide, 12 piers of 1.2 m each
+𝑐′𝑙𝑑 2𝑔(ℎ + ℎ𝑎)
Afflux Height, ha= 0.13179163 m Clear Waterway= 26 m
h= 1.33 m Overall Waterway= 40.4 m /
h+ha= 1.46 m Discharge Intensity, q= 4.582878 m Depth of Scour, R=1.35( )
d=FSL-Crest L= 0.39 m
(h+ha)^3/2= 1.76737297 U/S Sheet Piles D/S Sheet Piles
ha^3/2= 0.04784447 Depth of Scour, R= 3.85784806 Depth of Scour, R= 3.857848 m
Anticipated Scour=2.0R 7.71569612Anticipated Scour=1.25R 4.82231 m
q1= 2.92983682 RL Of Scour Bottom= 52.67 RL Of Scour Bottom= 55.18 m
q2= 1.67088604 Depth of U/S Cutoff, d= 5.94 Depth of D/S Cutoff, d= 1.31 m
Q=l*(q1+q2)= 119.154824 Max Static Head, H= 4.01 m
Waterway,l= 25.8991527 m Ge*d/H= 0.054543
λ= 34.09251
b/d=α= 67.17758
b= 89 m

2/7
Jiroga Weir Scheme-Glacis

1 Hydraulic Calculations for various flow conditions


(i) FSL Discharge passing down the regulator during high flood (ii) FSL Discharge passing down the regulator at Pond Level
U/S HFL= 61.44 m U/S WL= 60.39 m
DS WL= 60.00 m DS WL= 60.00 m
Head Causing Flow 1.44 m Head Causing Flow 0.39 m

Open the Gates Partially during Flood Open the Gates Partially during Flood
A=lx=>l= 26 m A=lx=>l= 26 m
C= 0.62 C= 0.62
Q=CA(2gh)^1/2= 119.154824 cumecs Q=CA(2gh)^1/2= 119.1548 cumecs
Gate Opening,x= 1.39064361 m Gate Opening,x= 2.672174 m
V,opening= 3.29550851 m/s V,opening= 1.715037 m/s
Hl,entry= 0.276768 m Hl,entry= 0.074958 m
U/S TEL= 62.00 m U/S TEL= 60.46 m
D/S TEL= 61.72 m D/S TEL= 60.39 m
Hl=D/S TEL-D/S WL 1.72 m Hl=D/S TEL-D/S WL 0.39 m

D/S Sp. Energy Lev= 4.063536 m D/S Sp. Energy Lev= 3.659916 m
U/S Sp. Energy Lev= 5.79 m U/S Sp. Energy Lev= 4.05 m
J Lev=D/S TEL-Ef2 57.66 m J Lev=D/S TEL-Ef2 56.73 m

3/7
Jiroga Weir Scheme-Glacis

Pressure Calculations

Top of Guide Bund

U/S TEL 62.00

U/S HFL 61.44 U/S TEL 61.72


Max PL 60.39 60.50 D/S WL 60.00
FSL Q= 119.154824 cumecs
Crest Level 60.11
U/S Bed L 58.61
Launching Apron CC Block 57.66
57.61 4.0100 3.0883 U/S Bed L56.49

CC Block Launching Apron

3.3655 55.24 0.4373 0.0000

1.19146122 55.18 0.31


52.39
89

Thickness= 0.6738

U/S Sheet pile D/S Sheet pile


d= 5.94 m d= 1.31 m
b= 89 m b= 89 m
b/d=α= 14.994029 b/d=α= 67.819338
λ= 8.01366932 λ= 34.413355
λ'= -7.0136693 1.119 m λ'= 33.413355
Pw thickness Pw thickness
φe= 77% 3.0883 0.735 m of D/S Floor φe= 0% 0.0000 1.246 m of CC Block
φd= 84% 3.3655 2.714 m of D/S Cutoff φd= 8% 0.3085 4.104 m of Cutoff
φc= 100% 4.0100 1.003 m of CC Block φc= 11% 0.4373 0.940 m of U/S Flloor

4/7
Jiroga Weir Scheme-Glacis

Wing Wall
Wt. of masonary= 1.9 t/m2 By Compressive Strength of Concrete
Wt. of dry earth= 1.6 t/m2 H<= 4.032258 m (OK) 0.8
Wt. of wet earth= 1.75 t/m2 61.44
Wt. of saturated earth= 2.2 t/m2 By Overturning Criterion
Wt. of concrete= 5.2 t/m2 B= 1.870069 m
Angle of Repose= 0.52359878 rad
Ka= 0.33333333 By Sliding Criterion
BC,allowable= 10 t/m2 B= 2.28125 m 60.39 Wet Soil
f,conc-mason= 0.65 Saturated Soil
f,conc-soil= 0.4 Provide B= 2.3 m
CS of Concrete= 250 t/m2
c= 5 t/m2
3.83

f L B V H lever Mr 2.78
Wing Wall 0.5 1.5 3.83 14.94675 1 14.94675

Lateral Pr 0.5 1.05 1.8375 0.9646875 3.1325 -3.021884


1 2.78 1.8375 5.11284375 1.39125 -7.113244
0.5 2.78 3.339 4.64538375 0.9275 -4.308593

Water Pr 0.5 2.3 2.78 -3.199875 1.533333 -4.906475 -19.350 0.5 0.3 58.61

Soil Wt 0.5 1.5 3.83 5.03015625 1.5 7.545234 22.492 57.61


1.5 1.8375 3.339
16.7770313 10.722915 2.3

2.78

FOS Sliding= 0.625838


FOS OvrTrn= 1.162365
SFF= 1.698308

5/7
Jiroga Weir Scheme-Glacis

Abutment
Wt. of masonary= 1.9 t/m2
Wt. of dry earth= 1.6 t/m2
Wt. of wet earth= 1.75 t/m2
Wt. of saturated earth= 2.2 t/m2
Wt. of concrete= 5.2 t/m2
Angle of Repose= 0.52359878 rad
Ka= 0.33333333
BC,allowable= 10 t/m2 Wet Soil
f,conc-mason= 0.65 Saturated Soil
f,conc-soil= 0.4
CS of Concrete= 250 t/m2
c= 5 t/m2

6/7