Вы находитесь на странице: 1из 4

15/8/2020 120H Motor Grader CAF00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3617 - 68) - Documentación

Pantalla anterior
Bienvenido: pvaldez
Producto: MO TO R GR ADER
Mode lo: 120H MO TO R GR ADER C AF
C onfiguración: 120H Motor Grade r C AF00001-UP (MAC HINE)
PO W ER ED BY 3126B Engine

Localización y Solución de Problemas


120H, 12H, 135H, 140H, 143H, 160H and 163H Motor Graders
Número de medio -RENR4104-12 Fecha de publicación -01/10/2014 Fecha de actualización -23/10/2014

i03530483

MID 081 - CID 1401 - FMI 05


SMCS - 5479-038-T3

Conditions Which Generate This Code:

Illustration 1 g01774857
Schematic of the solenoid valve (No. 1)

This diagnostic code is associated with the solenoid valve (No. 1). The FMI 05 means that the ECM has determined
that the current of the solenoid is below normal.

The possible causes of this diagnostic code are listed below:

The solenoid energizer circuit is open.

The return circuit of the solenoid is open.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sisweb/sis… 1/4
15/8/2020 120H Motor Grader CAF00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3617 - 68) - Documentación

The solenoid has failed.

The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original
diagnostic code has been corrected. Ensure that the diagnostic code of CID 1401 FMI 05 is active before
performing this procedure.

Note: Use a calibrated Digital Multimeter for the measurements in this procedure.

System Response:

When this diagnostic code is active, the ECM will turn off the current to the failed solenoid. Operation in the gears that
use this solenoid will not be allowed by the power train ECM.

Test Step 1. CHECK THE SOLENOID.

A. Turn the disconnect switch to the ON position.

B. Turn the key start switch to the ON position.

Note: Do not start the engine.

C. Disconnect the solenoid with the active diagnostic code from the machine harness.

D. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 752-YL) to contact
2 (wire 921-WH).

E. Observe the status of the CID 1401 FMI 05.

Expected Result:

The CID 1401 FMI 05 remains active. The FMI has not changed and the "05" is still active.

Results:

OK - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test
Step 2.

NOT OK - The diagnostic is no longer active. The solenoid has failed.

Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the
solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

STOP

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

A. Turn the key start switch and the disconnect switch to the OFF position.

B. Disconnect the machine harness connector(s) from the ECM.

C. The jumper wire that was installed in the previous test remains in place.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sisweb/sis… 2/4
15/8/2020 120H Motor Grader CAF00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3617 - 68) - Documentación

D. At the machine harness connector, measure the resistance from signal contact J1-4 (wire 752-YL) to contact J1-7
(wire 921-WH).

Expected Result:

The resistance is less than 5.0 ohms.

Results:

OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.

NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an
open circuit in the machine harness.

Repair: The open is in wire 752-YL or in wire 921-WH of the machine harness. Repair the machine harness or
replace the machine harness.

STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

A. Perform the following:

Inspect the contacts of the harness connectors.

Clean the contacts of the harness connectors.

B. Reconnect all harness connectors.

C. Turn the disconnect switch to the ON position.

D. Turn the key start switch to the ON position.

E. Operate the machine.

F. Check the status of the CID 1401 FMI 05.

Expected Result:

The CID 1401 FMI 05 is active.

Results:

OK - The CID 1401 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.

Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause
of the diagnostic code is not found, replace the ECM. See the Testing and Adjusting, "Electronic Control Module
(ECM) - Replace" Story in this manual for additional information.

STOP

NOT OK - The CID 1401 FMI 05 is not active. The diagnostic code does not exist at this time.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sisweb/sis… 3/4
15/8/2020 120H Motor Grader CAF00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3617 - 68) - Documentación

Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the
harness connectors that was disconnected and reconnected. Resume normal machine operation.

STOP