V3F20 PARAMETER CALCULATION rev 5.

2
Copyright (c) 2001 KONE Corporation, All Rights Reserved
INPUT DATA
&Elevator Speed (m/s) =
Elevator Speed (m/s)
&Gear Ratio (X:YY) =
Gear Ratio
&Traction dia. (mm) =
Traction sheave dia in mm
&Roping (1 or 2) =
Roping
&MOTOR TYPE:
S for Standard 340V KONE V3F20 motors, H for High Efficiency 360V motors
Motor &voltage =
Motor voltage
Motor &frequency =
Motor label frequency
Motor &current =
Motor nominal current
Motor cos(&phi) =
Motor cos(phi)
Motor &slip =
Motor slip
St&ator resist. =
Stator resistance
M&otor pole pairs =
Motor pairs of poles
Tacho P&ull.Ratio (1:Z)=
Press Alt+Key Down for non 1:1 tacho pulley ratio
Press Alt+Key Down for drop down motor list
CONFIG DATA dec hex Volts
C060 Nom.speed (m/s)=
C084 Acc./dec.(m/s2)=
C072 Max.slip (Hz) =
C074 Fsn (Hz) =
Select ?Hz freq. range on 385:A3
C076 K4 =
C078 K1 =
C07A K3 =
C07C K2 =
C080 P GAIN =
C082 I GAIN =
Tacho test voltage(V) = ? on 385:A1
C08A Tacho scaling =
Input help text
Input default
Input range
Ma&in power (V) =
Line supply voltage
Loa&d (kg) =
Load
&3rd Page
Use ENTER/RETURN or SPACEBAR to press
&Header Page
Use ENTER/RETURN or SPACEBAR to press
E&XIT
Use ENTER/RETURN or SPACEBAR to press
TAB, shift+TAB to move; ENTER/RETURN for defaults; Alt+letter for fast access
OUTPUT DATA
Nominal output voltage (V) =
Nomin. output frequency (Hz)=
Approx.V3F input current (A)=
Standard V3F20 module =
Typic. mach.room losses (kW)=
Rec.emerg.power gen.size(kW)=
NOTES
F&irst Page
Print to &Printer
Print to &File
E&XIT
&Elevator:
&Date/Designer:
I&ssue:
Seri&al number:
&Note:
P&roject:
Dia&gram:
V3F20 configuration sheet V20Cal 5.2
Use TAB or shift+TAB to move; Alt+letter for fast access
SPECIAL CASES. Page 3.
Autotransformer must be used.
(3 phase, YN connection, Isolation class F)
Voltage (V):
Primary
Secondary
Current (A):
Primary
Secondary
Power (kVA):
Output
Type
Frequency 50 or 60 Hz as supply.
Select Transformer from standard range in SOE-11.65.6 if possible.
&OK
&Cancel
&Reset
Use ENTER/RETURN or SPACEBAR to press
Tacho pulley ratio
&Motor end pulley diameter (mm) =
&Tacho pulley diameter (mm) =
Z =
&OK
&Cancel
Motor Voltage Saturation
Select one of the following:
Reduce Elevator Nominal Speed:
&Increase Main Line Voltage using autotransformer
&To the next lower standard value
&By 0.05 m/s
B&y 0.10 m/s
&OK
&Cancel
Arrow Keys to select, ENTER/RETURN or SPACEBAR to press
Configuration is written to
Tacho test voltage too high, increase tacho voltage. See SOE-
11.65.3, section 6.3.
Use INVMON Monitor display to load out of range parameters.
Elevator speed reduced to prevent Motor Voltage Saturation
Saturation of V3F output voltage
Cannot find file