Project Information

Project: Neyriz WWTP RO1 Flodose by BWA


Engineer: M. Valiollahi Program Version: 2.1
Client: Shavadoon Print Date: 21/05/2020

Plant Data
Feedwater Type: Waste Water
Feedwater Flow: 81.00 m³/h Concentrate Flow: 16.20 m³/h
Permeate Flow: 64.80 m³/h Recycle Flow: 0.00 m³/h
System Recovery: 80.00% RO Recovery: 80.00%
RO Membrane Type: Thin Film High Rejection Membrane Rejection: 99.22%

User Selection: – Flocon 260


Recommended Dose Rates: 1.08 mg/l - Feed 5.38 mg/l - Conc.
Est. Product Usage (100%): 2.09 kgs/day 0.76 MT/yr

Acid Dosing
Est. Acid Dose (100%): 0.00 mg/l - Feed
pH Control Method: None
Est. Acid Usage (100%): 0.00 kgs/day 0.00 MT/yr

mg/l at 30.0°C Raw Water Treated Feed Product Concentrate


Ca2+ 14.00 14.00 0.07 69.56
Mg2+ 21.88 10.00 0.05 49.68
Na+ 456.90 505.00 8.55 2,482.00
K+ 0.00 0.00 0.00 0.00
NH4+ 0.00 0.00 0.00 0.00
Ba2+ 0.00 0.00 0.00 0.00
Sr2+ 0.00 0.00 0.00 0.00
0.000 0.000 0.000 0.000
Fe2+/Fe3+/Mn2+
Al3+ 0.00 0.00 0.00 0.00

HCO3- 21.55 23.43 0.59 114.80


Cl- 493.08 493.08 8.20 2,423.40
SO42- 388.00 388.00 2.08 1,927.11
F- 0.00 0.00 0.00 0.00
NO3- 0.00 0.00 0.00 0.00
PO43- 0.00 0.00 0.00 0.00
SiO2 15.00 15.00 0.20 74.19
CO32- 0.97 33.49 0.01 163.92
CO2 0.06 0.00 0.00 0.01

TDS 1,411.38 1,482.00 19.75 7,304.66


Ionic Strength 0.03 0.03 0.00 0.14
pH 8.70 10.20 8.62 9.98

Saturation Index Raw Water Treated Feed Concentrate % Max SI of Flocon 260
(SI)
LSI -0.294 1.724 2.513 83.78%
SDSI N/A N/A N/A N/A
CaSO4 0.011 0.011 0.094 2.34%
BaSO4 0.000 0.000 0.000 0.00%
SrSO4 0.000 0.000 0.000 0.00%
CaF2 0.000 0.000 0.000 0.00%
SiO2 0.068 0.024 0.141 7.06%
Iron/Manganese 0.000 0.000 0.000 0.00%
Aluminium 0.000 0.000 0.000 0.00%

1 of 2
The information presented on or through the Software, including any data, results, information or reports generated, is made available solely for general information purposes. While such information is
believed by BWA Water Additives to be accurate, it is based on lab work and field testing under controlled conditions and the results achieved by Users under actual conditions are likely to vary. BWA Water
Additives do not warrant the accuracy, completeness, or usefulness of this information. Any reliance Users place on such information is strictly at Users’ own risk. BWA Water Additives disclaim all liability and
responsibility arising from any reliance placed on such materials by Users or by anyone who may be informed of any of its contents. For full Flodose® software Terms of Use, please refer to the Flodose®
website.

2 of 2