Академический Документы
Профессиональный Документы
Культура Документы
Technologies
andDivision
Drives
Operation
of
Perfect Harmony
via
Keypad
DriveAutomation
Technologies
andDivision
Drives
Table of Contents
Content Page
Operating Interface Keypad (Standard)……………….………………………………………….…… 3
Operating Interface Keypad (Multi-Language)…………….………………………………….….…… 4
Summary of Menus …………………………………………………………………..……….………… 5
Motor Parameter Menu ………………………………………………………………………….……… 6
Operating Mode Display in the “Main Menu“ …………………………………………………….…… 7
Actual Value Display ……………………………………………………………………………….…… 8
Selection of a Menu (Mainmenu and Submenu) ……………………………………..……………… 9
Selection of a Parameter ………………………………………………………………………….…… 10
Changing Parameter Values / Entry of numerical Values ……………………………………….…. 11
Changing Parameter Values (comparison of different keypads) …………….………………….…. 12
Security Code / Keypad Speed Demand………..……………………….……………………………. 13
Saving the Parameterization ……………………………………………………………………..……. 14
Data Transfer CPU CFC …………………..………………………..……………………………. 15
Content of the Compact Flash Card ………………………………………………………….….……. 16
Installation of Tool Suite ………………………………..…………………………………...……….…. 17
Duplicating the Compact Flash Card ……………………………………………………...……….…. 18
Other Functions of Menu “Configuration Update” ……………………………………..………….…. 19
“Firmware Update” (Update Flash Disk Files) ……………...…………………………..………….…. 20
DriveAutomation
Technologies
andDivision
Drives
SIEMENS
HELP
MAN.
STOP 0 SHIFT
LED
LED indications
indications and
and functional
functional assignments
assignments to
to buttons
buttons are
are identical
identical for
for either
either of
of the
the two
two keypads.
keypads.
Displayed
Displayed information
information is
is arranged
arranged differently,
differently, displayed
displayed text
text can
can be
be shown
shown in
in aa choice
choice of
of languages
languages
(English,
(English, French,
French, German,
German, Spanish
Spanish as
as selected
selected via
via Main
Main Menu,
Menu, ID
ID 5080).
5080).
Drive Menu
All
All parameters
parameters (ID)
(ID) are
are grouped
grouped in
in main
main menus
menus (1
(1 to
to 9).
9).
Functional
Functional groups
groups of
of main
main menus
menus are
are defined
defined as
as submenus
submenus (1000,
(1000, 1120,
1120, ...,
..., 2000,
2000, 2060,
2060, ...).
...).
Parameters
Parameters (ID)
(ID) by
by themselves
themselves represent
represent the
the content
content of
of the
the respective
respective submenus.
submenus.
DriveAutomation
Technologies
andDivision
Drives
The
The motor
motor menu
menu serves
serves to
to parameterize:
parameterize:
-- motor
motor data
data as
as per
per nameplate
nameplate
these
these are
are mandatory
mandatory to to be
be set
set in
in
accordance
accordance withwith the
the motor
motor
-- motor
motor substitute
substitute data
data
these
these might
might have
have to
to be
be programmed
programmed
for
for some
some applications
applications (more
(more details
details
in
in section
section “Motor
“Motor Theory”)
Theory”)
ID1060
ID1060 can
can be
be identified
identified “by
“by experiment”:
experiment”:
run
run the motor at small speed and
the motor at small speed and at
at “zero
“zero
load”
load” the stator current measured can
the stator current measured can
be
be set
set as
as “ID1060,
“ID1060, NoNo load
load current”.
current”.
For
For applications
applications with
with pumps
pumps and
and fans
fans the
the
default
default values
values as
as per
per parameter
parameter list
list will
will
be
be maintained
maintained for
for ID1070
ID1070 und
und ID1080.
ID1080.
Table
Table 7-6
7-6
Table
Table 7-7
7-7
DriveAutomation
Technologies
andDivision
Drives
operating OLTM DEMD FREQ VLTS ITOT physical quantities selected for indication
mode KYPD 50 25 1400 27 dynamically updated actual values
Out
Out of
of an
an extensive
extensive pick pick list
list (refer
(refer to
to the
the excerpt
excerpt
on
on the
the right)
right) four
four of
of the
the listed
listed variables
variables can
can be
be
selected
selected for
for indication
indication on on the
the standard
standard keypad.
keypad.
Menus
Menus are
are selected
selected directly
directly CANCEL
DRIVE
by
by using
using the
the assigned
assigned SHIFT
text/number
text/number keys.
keys. ENTER
2
Drive (2)
(Arrow Keys Select)
Drive parameters
(2000) (submenu)
DriveAutomation
Technologies
andDivision
Drives
Selection of a Parameter
Parameters
Parameters can
can be
be selected
selected within
within aa submenu
submenu or
or by
by direct
direct addressing
addressing (out
(out of
of any
any the
the state
state of
of indication).
indication).
Selection
Selection of
of aa parameter
parameter via
via submenu
submenu Direct
Direct selection
selection of
of aa parameter
parameter
Motor voltage
(1040) 4300V
Motor voltage
(m1040) 4300V
Change
Change of
of parameter
parameter values
values Entering
Entering decimal
decimal and
and hex
hex numbers
numbers
CANCEL Special
Special functions
functions
ENTER
CANCEL Resetting a parameter value
SHIFT SHIFT
ENTER to the current “Default” setting
Acceleration time 1
( 2270) 75s
* Direct addressing of a parameter
SHIFT
The asterisk ( ) indicates that this para- number out of any state of indication
*
meter has been changed as regards the
currently valid “Default” setting. Resetting the security
SHIFT 3x level to Zero (“operator“)
Reset to “Default” with
DriveAutomation
Technologies
andDivision
Drives
Approaching a parameter
from the assigned submenu
Speed setup
(2060) (submenu)
CANCEL
ENTER
or
Speed setup (2060)
(Arrow Keys Select)
Ratio control
(2070) -3.0 %
CANCEL
ENTER
Ratio control
(edit) - 003.0 %
change CANCEL
value ENTER
Ratio control
(2070) -1.0 %
Selection
Selection of
of the
the security
security level
level Changeover
Changeover to
to display
display mode
mode “Speed
“Speed menu”
menu”
CANCEL
SHIFT SHIFT
ENTER
Speed parameter
Enter Parameter ID 5500
Speed
Speed demand
demand via
via motorpot
motorpot
Enter security code
(5500) (functions) pre-condition:
Display mode “Speed menu“ is selected
CANCEL
OLTM DEMD RPM FREQ VLTS
ENTER OFF 0.0 0.0 0.0 0.0
Enter the security code:
0000 very limited access the speed demand value DEMD is
5555 for service and commissioning increased via ramp of the keypad
7777 comprehensive access (in 10s by 100%)
After
After switching
switching on on the
the electronic
electronic the speed demand value DEMD is
power
power supply
supply or or 15
15 minutes
minutes after
after the
the decreased via ramp of the keypad
last
last operation
operation of of any
any key
key security
security (in 10s by 100%)
level
level “0”
“0” is
is set
set automatically.
automatically.
DriveAutomation
Technologies
andDivision
Drives
Save
Save data
data in
in “non
“non volatile
volatile mode”
mode” Save
Save data
data as
as “Default
“Default parameterization”
parameterization”
Parameter values which have been changed are Press ENTER to proceed,
saved in “voltage failure proof” (on the CFC) CANCEL to abort
only after changeover to mode “Speed menu”.
CANCEL
ENTER
Reset
Reset all
all parameters
parameters to
to “Default”
“Default”
drive CFC
functions
system
program “SOP“
default
Reset to Factory Defaults
file “Defaults“
Set Factory Defaults
DriveAutomation
Technologies
andDivision
Drives
Compact Flash
system
program
“SOP“
operation
file
“Current“
default
file
“Defaults“
Essentially
Essentially the
the Compact
Compact Flash
Flash Card
Card contains
contains the
the Operating
Operating System,
System, the
the Booting-
Booting- and
and the
the User-Program
User-Program
For
For comprehensive
comprehensive commissioning
commissioning or
or service
service jobs,
jobs, the
the software
software ”Tool
”Tool Suite”
Suite” can
can be
be used
used with
with considerable
considerable advantage.
advantage.
The
The installation
installation is
is started
started via
via ”Tool
”Tool Suite
Suite Setup
Setup v...
v... .exe”.
.exe”.
Possibly,
Possibly, ”Microsoft.net
”Microsoft.net 2.0”
2.0” has
has to
to be
be installed
installed additionally.
additionally.
Monitor program only; no access to
change parameters, save data etc.
- 516.506 installation
- Air Cooled VFD Monitor
Former LV-VFD
of Robicon; no
longer sold but
still in the field.
DriveAutomation
Technologies
andDivision
Drives
1 2
A
A new
new Compact
Compact Flash
Flash Card
Card
has
has to
to be
be identical
identical in
in hardware
hardware
and
and must
must only
only be
be copied
copied
via Tool Suite
via Tool Suite
(to
(to provide
provide appropriate
appropriate formatting
formatting
and
and installation
installation of
of the
the boot
boot sector)
sector)
(1)
(1) Make
Make bootable
bootable default
default disk
disk
Serves to reformat any CFC in “Perfect Harmony style” and
installs all files required for NGX control.
(2)
(2) Copy
Copy setup
setup files
files to
to another
another directory
directory
Serves to update Tool Suite on laptop; same result is reached
by de-installing the old version of Tool Suite and installing the
new version.
(2) Take care to NEVER select the CFC as “Destination Drive …”.
(4)
(1) (3)
(3) Update
Update Tool
Tool Suite
Suite host
host files
files on
on PC
PC
Serves to update Configuration Files of drives already defined
in Tool Suite (provides the “new” range of parameters while
maintaining all settings); can be selected to update only one of
(3) several drives defined in Tool Suite by choosing the subfolder.
(4)
(4) Update
Update flash
flash disk files
disk files Firmware
Firmware Update
Update
This function updates the NXG Software ( Eagle Code) AND
the Configuration Files (range of available parameters) on the
Compact Flash Card (destination) to the new SW-release as
for
for details
details refer
refer to
to manual
manual 902291,
902291, topic
topic 5.3
5.3
selected in the Source Folder (e.g. FW 3.1.4 5.0.0).
DriveAutomation
Technologies
andDivision
Drives
2 5
4 3
6 7
copied to laptop by
installation of Tool Suite