Вы находитесь на странице: 1из 237

816R-2C

TECHNICAL MANUAL
OPERATION AND MAINTENANCE INSTRUCTIONS

TYPE 816R-2C FM TRANSMITTER


21.5 kW, 88-108 MHz
(PIN 180295-2)

Serial No. 369 and Above'

COPYRIGHT © 2005 by
CONTINENTAL ELECTRONICS
4212 S. BUCKNER BLVD.
DALLAS, TEXAS 75227

(214) 381-7161 www@contelec.com FAX: (214) 381 ..4949


ISSUED - 10 APRIL 1995
CHANGE 6 - 30 JUNE 2005
816R-2C

PREFACE

This Operation and Maintenance manual gives the physical and functional description, installation, operation, theory of
operation, maintenance, parts lists, and diagrams for the identified equipment. Operator and service personnel should
become familiar with the manual contents before attempting to install, operate, or maintain the equipment. In addition to the
Safety Summary which follows the Table of Contents, specific WARNINGS, CAUTIONS and NOTES are located
throughout this manual where they apply. Continental Electronics (CE) manufactured this equipment to conform with
current electrical, radiation, and safety codes of the United States to the extent that they apply. It is the user's responsibility
to comply with all local and national codes during installation and operation of the equipment.

CE reserves the right to make any changes, without notice, to this or any of CE' s products to improve reliability,
performance, function, or design.

CE does not assume any liability resulting from the application or use of any product or circuit described herein; nor does CE
convey any license under its patent rights or the rights of others.

The information in this document has been carefully checked and is believed to be entirely reliable. While all reasonable
efforts to ensure accuracy have been taken in the preparation of this manual, CE assumes no responsibility resulting from
omissions or errors in this manual, or from the use of information contained herein.

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency
that might be met during installation, operation, or maintenance. Should further infonnation be desired or should particular
problems arise which are not covered sufficiently for the user's purpose, the matter should be referred to CEo

All Rights Reserved

This document contains proprietary information of


Continental Electronics and shall not be duplicated,
nor its contents used for any purpose, unless express
written permission is obtained from Continental
Electronics .

CUSTOMER SERVICE

Continental Electronics customer service is available for assistance at any time, 24 hours a day, weekends and holidays
included. Call anytime day or night:

Parts Services (214) 388-3737


Engineering Services (214) 388-5800
Main Offices (214) 381-7161 (8:00 am-5:00 pm CT)
Web Address www@contelec.com

You may write to any of these services at 4212 S. Buckner Blvd, Dallas, Texas 75227-0879, or FAX (214) 381-4949.

Change 6
816R-2C
INSERT LATEST CHANGE PAGES. DESTROY SUPERSEDED PAGES.

ILIST OF EFFECTIVE PAGES I


NOTE: The portion of text affected by the changes is
indicated by a change number located in the footer of
each changed page.

Dates of original and change pages are:


Original. 0 .., .. , 19 August 1995
Change 1 9 July 1996
Change 2 9 September 1997
Change 3 15 May 1998
Change 4 10 January 2000
Change 5 24 January 2003
Change 6 30 June 2005

TOT.!~ NUMBER OF PAGES IN THIS PUBLICATION IS 235 CONSISTING OF THE FOLLOWING:

Page No. *Change Page No *Change Page No 0 •••••••••• *Change

Titie? . 6 4-9 0 6-88 . 4


pret'J.ce . 6 4-10-4-11 5 6-89 - 6-90 . 5
A 6 4-12 0 6-91 Blank . 4
4 4-13 5 6-92 - 6-96 _ . 4
II 5 4-14 0 6-97 Blank . 4
III \11 . . . . . . . . . . . • . . . . . . . . . 3 4-15-4-20 5 6-98 - 6-101 . 4
VII; 31ank . 3 5-1 5 6-102 Blank . 2
ix - \ tii . o 5-2 0 7-1 . 5
xi Slank' . o 5-3 5 7-2 Blank . 4
1-' 1-2 . 5 5-4 - 5-7 0 7-3 . o
].: . 1-4 . o 5-8-5-10.... 5 7-4 Blank . o
5 5-11 - 5-20 ., . . . . . . . . . . . . . . . 0 7-5 ., . 3
=-~ - 2-3 . o 5-21 5 7-6 Blank , , o
Blank . o 5-22 - 5-23 0 7-7 . o
2-7 . o 5-24 Blank 0 7-8 Blank . o
.:::-, - 2-9 . 5 6-1 5 7-9 . o
- 2-12 . o 6-2 6 7-10 Blank . o
4 6-3 - 6-5 5 7-11 . o
.::: .. ~ - 2-15 . o 6-6 Blank '" . .. .. 4 7-12 Blank . o
= ') Blank . o 6-7 - 6-20.. . . . . . . . . . . . . . . . . 4 7-13 . 4
3- ·3-2 . 5 6-21 - 6-24 5 7-14 Blank . o
3 -~ - 3-7 . o 6-25 Blank. . . . . . . . . . . . . . . . . 4 7-15 . 4
3- ". - 3-9 . 5 6-26 - 6-42 ........ 4 7-16 Blank . o
3- . ~ o 6-43 5 7-17 . 4
3-; l - 3-12 . 5 6-44 - 6-50 '" . . . . . . . . . . . . . . 4 7-18 Blank . o
3·;' - 3-14 . o 6-51 5 7-19 . 5
3-: . 5 6-52 - 6-58 4 7-20 Blank , . o
3-1·") - 3-19 . o 6-59 Blank .. . . . . . . . . . . . . . . . 4 7-21 . 4
3-2') Blank . o 6-60 4 7-22 Blank , ., ., o
4-1 . 5 6-61 - 6-62 6 7-23 . o
4-2 . 3 6-63 Blank '" . . . . . . . . . . . . . . 4 7-24 Blank . o
4-2. t ••.••••.•....•••••..•. 5 6-64 - 6-68 4 7-25 . 3
4-2 _:2 Blank . 3 6-69 Blank .......... 4 7-26 Blank " . 3
4-3 . 5 6-70 4 7-27 . 3
4-4 . o 6-71 6 7-28 Blank . 3
4-5 ." . 3 6-72 4 7-29 . 3
4-6 > ••• '" •••••••••••••• o 6-73 5 7-30 Blank . 3
4-7 4 6-74 - 6-85 4 7-31 . 5
4-8 . 3 6-86 Blank ............ 4 7-32 Blank . 3
6-87 5

*Zero in the column indicates an original page.

A Change 6
816R-2C TABLE OF CONTENTS

Paragraph Title Page

SECTION 1 - GENERAL

1-1. Introduction . 1-1


1-2. Functional Description . 1-1
1-3. Physical Description . 1-1
1-4. Technical Characteristics . 1-1

SECTION 2 - INSTALLATION

2-1. Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2-1.1 AC Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-1.2 RF Output Power 2-1
2-1.3 Transmitter Cooling .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-1.3.1 Exhaust Fans 2-1
2-1.3.2 Positive Pressure 2-2
2-1.3.3 Transmitter Exhaust Duct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-2. Unpacking and Inspecting 2-6
2-2.1 Domestic Shipments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-2.2 International Shipments 2-6
2-3. Assembly 2-7

SECTION 3 - OPERATION

3-1. General . 3-1


3-2. Controls and Indicators . 3-1
3-3. Initial Turn-On Procedure . 3-1
3-4. Remote Operation . 3-15
3-5. 2nd Power Level (Low Pwr) Adjustment . 3-15
3-6. Automatic Recycle Resetting . 3-15
3-7. Nonnal Tum-Off (Local) . 3-15
3-8. Emergency Tum-Off . 3-15

SECTION 4 - THEORY OF OPERATION

4-1. General 0 •••••• 4-1


4-2. Functional Description 0 •••••••••• 4-1
4-3. RF Circuits . 4-1
4-3.1 Exciter, A4. . . 4-1
4-3.2 IPA, A3 . 4-1
4-3.2.1
4-3.2.2
IPA Metering, A3A1
IPA Status, A3A2
.
.
4-1
4-1
I
4-3.2.3 Amplifier Assembly, A3A3. . . 4-1
4-3.2.3.1 RF Amplifier, Al . 4-2
4-3.2.3.2 Control Assembly . 4-2
4-3.3 RF Power Amplifier, A12 . 4-2
4-3.4 Low-Pass Filter, A7 . 4-2.1
4-3.5 Directional Coupler, DCl . 4-2.1

Change 4
TABLE OF CONTENTS 816R-2C

Paragraph Title Page

SECTION 4 - THEORY OF OPERATION - Continued

4-4. Power Supplies and Power Control Circuits , . 4-2.1


4-4.1 General 0 ••• 0 0 •••••• 4-2.1
4-4.2 24 V dc Power Supply, PIO A10 . 4-2.1 I
4-4.3 Power Amplifier Bias Power Supply, PIO A10 0 •••••• 4-2.1
4-4.4 PA Plate Supply . 4-10
4-4.5 Power Control Unit, A9 . 4-10
4-4.6 Power Control Regulator, PIO A2A6. . . 4-10
4-4.7 PA Screen Power Supply 0 •••••••••••••• 4-10
4-4.8 Driver Power Supply, PIO A5 . 4-10
4-4.9 Filament Voltage Regulator, A2A4 . 4-10
4-4.10 Filament Voltage Distribution 0 • 4-13
4-5. Primary Power Distribution Control and Overload Circuits . 4-13
4-5.1 Primary Power Distribution . 4-13
4-5.2 Transmitter Turn-On. . 0 ••••••••••••• 0 ••••••••••••••••••••••••••••• 4-13
4-5.3 Exciter Power Control Override. . 0 • 4-16
4-5.4 FWDIREFL Calibrate and Auto Power Control Unit, A2A6. . . 4-16
4-5.4.1 Functions. . 0 •••••• 0 • 4-16
4-5.4.2 Theory of Operation. . . 4-16
4-5.5 Overload Protection 0 •••••••••••••• 4-17
4-5.6 Overload and Recycle Board, A2A5 0 •••••••• 4-17
4-5.7 Power Failure Recycle Board, A8A 1. . 0 4-18
4-5.8 Auto-Manual Power Control Latching Relay and Transmitter Status Indicators. . . 4-18
4-5.9 Power Control Relays, PIO A 1OA2 0 4-18
4-5.1 0 Remote Relays, PIO A10A2 . 4-18

SECTION 5 - MAINTENANCE

5-1. Routine Maintenance 0 ••••••••••••••••••••••••• 0 • • • • • • • • • • • • • • • • • • 5-1


5-2. Cleaning o. . . 0 •••• 5-1
5-2.1 General Cleaning Procedures. . 0 • • • • • • • • • • • • • • • • • • 5-1
5-2.2 Air Filter. 5-1
5-2.3 Tube Cleaning. 5-1
5-3. Inspection ........ 5-1
5-4. Lubrication 5-1
5-5. Parts Replacement 5-1
5-5.1 PA Tube, VI 0 • • 5-2
5-5.2 Fuse Replacement. 5-2
5-6. Troubleshooting 0 • • • • • • • 5-2
5-6.1 Access Panel Interlock Switch. 5-2
5-6.2 Test Equipment. . 0 5-2
5-6.3 Troubleshooting the Power Controller. 0 • • • • • • • • • 5-2
5-7. Adjustments 5-3
5-7.1 Switch Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5-7.1.1 Air Interlock Switch, AI2S1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5-7.1.2 Tuning Motor Limit Switches, AI2S 11-S 14 0 • • 5-3

ii Change 5
816R-2C TABLE OF CONTENTS

Paragraph Title Page

SECTION 5 - MAINTENANCE - Continued

5-7.2 Filament Voltage Adjustment. . 5-3


5-7.3 DC Overload Adjustment. . 5-6
5-7.3.1 PA Plate Overload Adjustment. . . 5-6
5-7.3.2 PA Screen Overload Adjustment. . 5-6
5-7.4 PA Grid Current. . . 5-7
5-7.5 High Voltage Power Supply Static Check (no drive) . 5-7
5-7.6 IP A Metering Board Calibration . 5-7
5-7.6.1 General Information. . . 5-7
5-7.6.2 Setup Procedures . 5-7
5-7.6.3 Calibration Procedures. . . 5-8
5-7.7 FWDIREFL CAL and Power Control Card, A2A6. . . 5-9
5-7.7.1 Offset Nulls. . . 5-9
5-7.7.2 Forward Power Calibration . 5-10
5-7.7.3 Reflected Power and VSWR Protection Calibration . 5-10
5-7.7.4 VSWR Foldback Adjustment. . 5-10
5-7.8 Phase Monitor Adjustment. . 5-11
5-8. Changing Power . 5-11
5-9. Changing Frequency . 5-11
5-9.1 Frequency Change Adjustments. . . 5-11
5-9.1.1 Shorting Plane . 5-11
5-9.1.2 PA Neutralization. . . 5-12
5-9.1.3 PA Grid Tuning Slider . 5-12
5-9.1.4 PA Grid Swamping Capacitor. . 5-12
5-9.1.5 Cathode Return Capacitor. . 5-12
5-9.1.6 Efficiency Capacitor. . 5-12
5-9.1.7 Coupling Capacitor. . 5-12
5-9.1.8 PA Bias . 5-12
5-9.1.9 IPA to PA Cable Length. . . 5-21
5-9.1.10 PA Grid Circuit. . . 5-21
5-9.2 PA Tuning and Loading. . . 5-22
5-9.3 PA Neutralization. . . 5-23

SECTION 6 - PARTS LISTS

6-1. Introduction . 6-1


6-2. Reference Designations (Ref Des) . 6-1
6-3. Description . 6-1
6-4. Part Number . 6-1
6-5. Illustrations . 6-1
6-6. Index of Parts Lists 0 ••••••••••••••• 6-1

SECTION 7 - DIAGRAMS

7-1. Introduction 7-1

Change 3 iii
TABLE OF CONTENTS 816R-2C

LIST OF ILLUSTRATIONS

Figure Title Page

SECTION 1 - GENERAL

1-1. 816R-2C FM Transmitter. 1-2

SECTION 2 - INSTALLATION

2-1. FM Transmitter Outline and Installation Drawing . 2-3


2-2. FM Transmitter Nominal Heat Balance . 2-5
2-3. Remote Control Connections . 2-8
2-4. Transmitter Controller (377D-l or -2) Connections . 2-9
2-5. Remote Plate Current Sample Circuit . 2-10
2-6. Transformer Connection Schedule . 2-12
2-7. IPA Transformer (T3) Connection . 2-13
2-8. Secondary Tap Configuration, T2 . 2-15

SECTION 3 - OPERATION

3-1. Transmitter Control Panels. . . 3-2


3-2. Control Panel, AI, Controls (Sheet 1 of 2). . . 3-3
3-2. Control Panel, AI, Status Indicators (Sheet 2 of 2) . 3-4
3-3. Card Cage Assembly, A2, Controls and Indicators . 3-8
3-4. IPA, A3, Controls and Indicators . 3-8
3-5. Circuit Breaker Panel, A6, Controls and Indicators . 3-10
3-6. PA Tuning and Loading . 3-14
3-7. Amplifier Efficiency vs. Frequency and Po . 3-18
3-8. Power to VSWR Conversion Graph . 3-19

SECTION 4 - THEORY OF OPERATION

4-1. FM Transmitter 816R-2C, Block Diagram . 4-3


4-2. RF Drive Path. . . 4-4
4-3. IPA Block Diagram, A3. . . 4-5 I
4~4. SCR Power Control, Simplified Diagram. . . 4-6
4-5. Power Amplifier DC Bias Circuitry Simplified Schematic . 4-7
4-6. PA Cavity, A12 . 4-8
4-7. P A Tuning Circuit, Simplified . 4-9
4-8. Power Control Circuits, Simplified Diagram. . . 4-11
4-9. Filament Voltage Distribution . 4-14
4-10. AC Power Distribution. . . 4-15

iv Change 3
816R-2C TABLE OF CONTENTS

LIST OF ILLUSTRATIONS - Continued

Figure Title Page

SECTION 4 - THEORY OF OPERATION - Continued

4-11. Latching Relay Simplified Schematic . 4-19


4-12. Power Control Relays Simplified Schematic. . . 4-20

SECTION 5 - MAINTENANCE

5-1. Primary AC Wiring, Power Control. . 5-4


5-2. PA Plate Tuning Cavity Slider, Coarse Adjustment. . 5-13
5-3. PA Neutralizing Adjustment. . 5-14
5-4. Graph for Coarse Setting of PA Grid Tuning Inductors. . . 5-15
5-5. Power Amplifier Tube Socket (Bottom View), A12A3 . 5-16
5-6. PA Grid Swamping Capacitor. . 5-17
5-7. PA Socket, Cathode Return Capacitors . 5-18
5-8. Adjustment of Cathode Return Capacitors. . . 5-19
5-9. Cathode Return Capacitor Position vs. Frequency . 5-20
5-10. IPA to PA Cable Length. . . 5-21

SECTION 6 - PARTS LISTS

6-1. 816R-2C FM Transmitter (Sheet 1 of2) . 6-3


6-1. 816R-2C FM Transmitter (Sheet 2 of2) . 6-4
6-2. Control Panel, AI . 6-8
6-3. Control Panel Circuit Card Assembly, A 1A 1. . . 6-10
6-4. Card Cage, A2 . 6-18
6-5. Filament Regulator Circuit Card Assembly, A2A4. . . 6-20
6-6. Overload/Recycle Circuit Card Assembly, A2A5 . 6-26
6-7. Power Monitor/Control Circuit Card Assembly, A2A6 . 6-30
6-8. Card Cage Component Circuit Card Assembly, A2A7 . 6-36
6-9. Backplane Circuit Card Assembly, A2A8. . . 6-40
6-10. Power Control Assembly, A2A9 . 6-42
6-11. Intermediate Power Amplifier Assembly, A3 . 6-44
6-12. IPA Metering Circuit Card Assembly, A3A1 . 6-46
6-13. LED Assembly, A3A2. . . 6-50
6-14. Amplifier Assembly, A3A3 . 6-52
6-15 Amplifier Module, A3A3A1-A2 . 6-54
6-16 RF Circuit Card Assembly, A3A3A1-A2A1 . 6-56
6-17 Control Circuit Card Assembly, A3A3A1-A2A2 . 6-58
6-18. Component Shelf Assembly, AS . 6-62
6-19. IPA Metering Circuit Card Assembly, ASA1 . 6-66
6-20. Circuit Breaker Assembly, A6. . . 6-68
6-21. Low Pass Filter Assembly, A7 . 6-72
6-22. Component Panel Assembly, A8. . . 6-74
6-23. Power Failure Recycle Circuit Card Assembly, A8A 1 . 6-76
6-24. Variac Driver Assembly, A8A2 . 6-78

Change 3 v
TABLE OF CONTENTS 816R-2C

LIST OF ILLUSTRATIONS - Continued

Figure Title Page

SECTION 6 - PARTS LISTS - Continued

6-25. SCR Assembly, A9 . 6-80


6-26. Power Supply Assembly, A10 . 6-82
6-27. Bias Component Circuit Card Assembly, AlOAl . 6-84
6-28. Remote Control Circuit Card Assembly, AlOA2 . 6-86
6-29. PA Cavity Assembly (Front View), A12. (Sheet 1 of2) . 6-89
6-29. PA Cavity Assembly (Rear View), A12. (Sheet 2 of 2) . 6-90
6-30. Metering Multiplier Circuit Card Assembly, A12Al . 6-94
6-31. Metering Multiplier Circuit Card Assembly, A12A2 . 6-96
6-32. PA Tube Socket Assembly, A12A3 . 6-100
6-33. Bleeder Resistor Assembly, A13 . 6-102

SECTION 7 - DIAGRAMS

7-1. Control Panel (Sht. 1 of 2) . 7-3


17-1.
7-2.
Control Panel (Sht. 2 of 2)
Filament Regulator Schematic Diagram. .
.
.
7-5
7-7
7-3. Overload/Recycle Schematic Diagram. . . 7-9
7-4. Power Monitor/Control Schematic Diagram . 7-11
7-5. Card Cage Components . 7-13
7-6. Backplane Schematic Diagram (Sheet 1 of 2) . 7-15
7-6. Backplane Schematic Diagram (Sheet 2 of 2) . 7-17
17-7. Intermediate Power Amplifier (IPA) 816R Schematic Diagram . 7-19
7-8. Driver Metering Schematic Diagram . 7-21
7-9. IPA Status Schematic Diagram. . . 7-23
7-10 Amplifier Module Schematic Diagram . 7-25
7-11 Control Circuit Card Assembly . 7-27

17-12
7-13
RF Circuit Card Assembly Schematic Diagram
Remote Control Schematic Diagram
.
.
7-29
7-31

vi Change 3
816R-2C TABLE OF CONTENTS

LIST OF TABLES

Table Title Page

SECTION 1 - GENERAL

1-1. Technical Characteristics 1-3

SECTION 2 - INSTALLATION

2-1. Screen Voltage Transfonner Tap Schedule . 2-14

SECTION 3 - OPERATION

3-1. Control Panel, A 1, Controls and Indicators . 3-5


3-2. Card Cage Assembly, A2, Controls and Indicators . 3-9
3-3. IPA, A3, Controls and Indicators . 3-9
3-4. Circuit Breaker Panel, A6, Controls and Indicators . 3-11
3-5. Nominal Operating Parameters vs. Power Levels . 3-16
3-6. Nominal Operating Parameters vs. Frequency . 3-17

SECTION 4 -THEORY OF OPERATION

(No Tables In This Section)

SECTION 5 -MAINTENANCE

5-1. Required Test Equipment . 5-2

SECTION 6 -PARTS LISTS

6-1. Index of Parts Lists . 6-1

SECTION 7 -DIAGRAMS

7-1. Index of Schematic Diagrams . 7-1

Change 3 vii
TABLE OF CONTENTS 816R-2C

(This Page Intentionally Left Blank)

viii Change 3
816R-2C SAFETY SUMMARY

SAFETY INFORMATION

I GENERAL
WARNING
This safety summary is intended for trained and qualified BITE HAZARD
personnel who are aware of the dangers inherent in handling
potentially hazardous electrical circuits. It is not intended as USE CAUTION WHEN PLACING
a complete or authoritative medical treatment course, but FINGERS IN VICTIMS MOUTH, MUSCLE
should serve as a reminded of accepted emergency SPASMS CAN CAUSE THE MOUTH TO
techniques. The equipment documentation must be reviewed CLOSE WITH FORCE SUFFICIENT TO
for familiarization with safety markings and instructions SEVER YOUR FINGERS. FAILURE TO
before operation or maintenance activities are attempted. COMPLY MAY RESULT IN LOSS OF
Know where and how to tum off main electrical power to FINGERS.
the equipment. User personnel should have training in first
aid and cardiopulmonary resuscitation (CPR) techniques.
Emergency medical, fire, and ambulance telephone numbers a. Airway - If victim is unconscious, open airway
should be posted in clear view adjacent to each telephone. by lifting up the neck while pushing back on the
Make a note if 911 service is available. victims forehead. Refer to Figure 1A. Clear
mouth of obstructions and observe for breathing.

II ELECTRICAL SHOCK TREATMENT


WARNING
In case of an electrical shock the A-B-Cs of basic life RESCUER KEEP CALM
support treatment may be used while medical assistance is
being summoned. EXCESSIVELY DEEP AND RAPID
BREATHING BY THE RESCUER MAY
RESULT IN RESCUER BECOMING
WARNING FAINT, TO TINGLE, AND EVEN LOSE
HIGH VOLTAGE/RF HAZARD CONSCIOUSNESS. BREATHING SHOULD
BE NORMAL IN RATE WITH ONLY
WHEN A VICTIM IS IN CONTACT WITH MODERATE INCREASE IN VOLUME.
HIGH VOLTAGE OR RF, ENSURE SOURCE FAILURE TO COMPLY MAY RESULT IN
POTENTIAL IS REMOVED AND CIRCUIT RESCUE BEING PREMATURELY
GROUNDED BEFORE ATTEMPTING STOPPED DUE TO FATIGUE.
ARTIFICIAL RESPIRATION. FAILURE TO
COMPLY MAY RESULT IN PERSONAL b. Breathing - If victim is not breathing begin
INJURY OR DEATH. artificial breathing. Tilt head, pinch nostrils,
make airtight seal with your mouth, and blow 4
quick full breaths into the victims lungs. Refer to
1. If the victim is not responsive follow the A-B-Cs of Figure lB.
basic life support. Place victim face-up on a flat hard
surface. Three critical areas (Airway, Breathing, and c. Circulation - If victim does not have a pulse, see
Circulation) need immediate attention: Figure 1C, begin artificial circulation. Depress
sternum 1Y2 to 2 inches then release. Refer to
Figures ID and IE. WITH ONE rescuer:
Perform 15 compressions and 2 quick breaths at
the rate of 80 per minute. WITH TWO rescuers:
Perform 5 compressions and 1 breath at the rate
of 60 per minute.

ix
SAFETY SUMMARY 816R-2C

... -.
• • • • • • • • fit

94G0309

Figure 1. Artificial Breathing and Circulation.

2. If the victim is responsive treat for shock in the 1. In case of extensive electrical bums and broken skin:
following way:
a. Cover area with clean sheet or cloth. (Cleanest
a. Keep victim warm. available cloth article.)

b. Keep victim as quite as possible. b. Do Not break blisters, remove tissue, remove
adhered particles of clothing, or apply any salve
c. Loosen victims clothing. or ointment.

d. Place victim in a reclining position if possible. c. Treat victim for shock as follows: Keep victim
warm, quite, reclined, and loosen clothing.

III FIRST-AID d. Arrange transportation to a hospital as quickly as


possible.
Users of this equipment are urged to become familiar with
first-aid theory and practices. The following information is
intended for reference only. It is important that all personnel
using this equipment be prepared to give adequate
Emergency First-Aid to fellow users.

x
816R-2C SAFETY SUMMARY

III FIRST-AID - Continued CAUTION

The CAUTION sign as shown above, denotes an


e. If arms or legs are affected keep them elevated. equipment hazard. It calls attention to an
operating procedure, practice, or the like, which,
NOTE if not correctly performed or adhered to, may
result in damage to or destruction of part or all of
If medical help will not be available within an the equipment. Do not proceed beyond a
hour and the victim is conscious and not CAUTION sign until the indicated conditions
vomiting, give him a weak solution of salt and are fully understood and met.
soda: 1 level teaspoon of salt and 1/2 level
teaspoon of baking soda to each quart of
water (neither hot nor cold). Allow victim to V SAFETY PRECAUTIONS
sip slowly about 4 ounces (a half glass) over a
period of 15 minutes. Discontinue fluid if Follow the safety precautions listed below in addition to any
vomiting occurs. (Do Not give alcohol.) site safety precautions when servicing this equipment.
Failure to observe these safety precautions may result in
serious injury or death.
2. In case of less severe electrical burns (1 st. or 2nd.
degree) with no broken skin:
WARNING
a. Apply cool (not ice cold) compresses using the
cleanest available cloth article. DEATH OR SERIOUS INJURY MAY
RESULT IF PERSONNEL FAIL TO
b. Do Not break blisters, remove tissue, remove OBSERVE THE FOLLOWING SAFETY
adhered particles of clothing, or apply any salve PRECAUTIONS.
or ointment.

c. Apply clean dry dressing if necessary. 1. Never work on electronic equipment unless there is
another person present who is familiar with the
d. Treat victim for shock as follows: Keep victim operation and hazards of the equipment and who is
warm, quite, reclined, and loosen clothing. competent in administering first aid. When the
engineer or technician is aided by operators, he must
e. Arrange transportation to a hospital as quickly as warn them about dangerous areas.
possible.
2. Do not contact high voltage or current connections
f. If arms or legs are affected keep them elevated. when power is applied to this equipment.

3. Whenever the nature of the procedure permits, keep


IV SAFETY SYMBOLS one hand away from the equipment to reduce the
hazard of current flowing through vital organs of the
Safety symbols shown below are typical of those used in the body.
operation and maintenance manual:

WARNING

The WARNING sign as shown above, denotes a


personal hazard. It calls attention to a procedure,
practice, or the like, which, if not correctly
performed or adhered to, may result in personal
injury. Do not proceed beyond a WARNING
sign until the indicated conditions are fully
understood and met.

xi
SAFETY SUMMARY 816R-2C

V SAFETY PRECAUTIONS - Continued a. Proper precautions shall be taken to protect


cardiac pacemaker users.

4. Make sure that all rings, watches, necklaces, metallic b. Ensure that radiation restrictions for nearby
ear-rings, and other similar items are removed before equipment or other high power rf radiation
working with this equipment. sources are observed before performing
maintenance on this equipment.
5. Whenever possible, the power supply to the equipment
must be turned-off and tagged or locked before c. Prior to and during operation and maintenance,
beginning work on the equipment. observe all radiation restrictions in effect at the
site.
6. Extremely high current, low voltage, dc is used in
portions of the equipment. Do not be misled by the d. If personnel are suspected or known to have been
low voltage rating (5 to 30 V dc) of the current exposed to rf radiation in excess of rf radiation
sources. Severe injury to personnel and damage to the protection guidelines, consult medical personnel
equipment can occur if the voltage sources are shorted immediately.
(directly connected) to ground or ground returns by
tools or test equipment.
VIII TOXIC MATERIAL/ENVIRONMENTAL
VI VOLTAGE, CURRENT, and LIGHTNING HAZARDS
HAZARDS
The hazards listed in 1 and 2 below may exist when
The voltage, current, and lightning hazards listed in 1 performing maintenance of the equipment. For hazards
through 3 below exist for the equipment. For hazards associated with vendor equipment, refer to appropriate
associated with vendor equipment, refer to appropriate manuals furnished with the item.
manuals furnished with the item.
1. Toxic or flammable solvents and corrosive chemicals
1. The dc voltage hazards consist of potentials of 5 V dc used in cleaning operations may involve the use of
to 10kV dc between power supply lines within the caustic or acid solutions, skin irritants, and organic
equipment. solvents that are flammable and/or toxic. The
following precautions, as a minimum, must be
2. High voltage, high current, 50/60 Hz ac power is observed by personnel using such materials.
supplied to the equipment.
a. Work only in well ventilated areas.
3. Antenna systems acting as an attracting device
presents a lightning hazard to personnel performing b. Wear organic vapor respirators when using
maintenance on the equipment. No maintenance organic solvents or corrosive chemicals.
should be performed on the unit when thunderstorms
are imminent or in progress, while the antenna is c. Wear chemical safety goggles, gloves and aprons
connected. when using corrosive chemicals.

d. Do not use flammable chemicals near or inside


VII RF RADIATION HAZARDS the equipment while power is applied to the
system.
The rf radiation hazards listed in 1 and 2 below exist for the
equipment. For hazards associated with vendor equipment, e. Maintain a fully stocked first aid cabinet nearby
refer to appropriate manuals furnished with the item. for emergency treatment of scalds, burns, etc.

1. RF radiation from the equipment could present a f. Flush away coolant or cleaning solvent
potential hazard to personnel wearing cardiac contamination from any part of the body.
pacemakers.
2. Benzene, Carbon Tetrachloride, Freon,and
2. The following rf radiation hazard precautions shall be Trichloroethane based Solvents should only be used in
observed when operating or performing maintenance well ventilated areas. The fumes are toxic and may be
on the equipment: hazardous to your health or can cause death by
suffocation.

xii
816R-2C SAFETY SUMMARY

IX MAJOR EMPLACEMENT AND 2. Electrostatic handling of MOS devices is of prime


MAINTENANCE HAZARDS importance. Stati~ electricity is always present in any
work environment. It is generated when ever two
The precautions given in 1 and 2 below must be observed to different materials are rubbed together. A person
prevent injury or death to personnel: walking across the floor can generate a charge of
thousands of volts. A person working at a bench,
1. Installation and assembly hazards associated with the sliding around on a stool, or rubbing his arms on the
equipment are as follows: work bench can develop a high static potential. For
preventing damage to devices due to ESD, use the
a. After performing maintenance ensure the doors following precautions:
and covers are installed prior to attempting to
return the equipment to service. a. Table tops or work areas should be covered with
grounded conductive tops. Test areas should
b. On all electrolytic capacitors, make sure terminal have conductive floor mats.
polarity markings [positive (+) and negative (-)]
are observed when connecting capacitors to ± dc b. Tools and test equipment used in protected work
buses. areas shall be properly grounded. Ensure that
soldering-iron tips are grounded. If plastic
2. While performing maintenance on the equipment, handled tools must be used, they shall be treated
observe the following precautions: with a topical antistat.

a. Maintenance of equipment shall not be c. Devices, or circuit cards with devices, should not
performed when thunderstorms and lightning are be inserted into or removed from circuits with
imminent or in progress. the power on because transient voltages may
cause permanent damage.
b. When performing maintenance on the equipment
make sure all ac power to the unit is removed. d. Use a conductive wrist strap when removing a
circuit card containing MaS/CMOS devices
from a card cage or when removing a device
X STATIC SENSITIVE DEVICES from a circuit card.

There are some circuits throughout the equipment using e. The devices are to be stored or transported in
metal-oxide-semiconductor (MaS) and complementary static shielding bags, anti-static rails, or
MaS (CMOS) integrated circuits. This requires stringent conductive foam.
attention to handling techniques due to the sensitivity to
static electricity. The following paragraphs outline the 3. ESD grounding is critical to safe handling of ESD
procedures to use when handling MaS or CMOS devices. sensitive devices. Earth ground rods for ESD
protection shall be solid copper or copper jacketed
1. Electrostatic discharge hazards in MaS/CMOS steel and shall be driven six to eight feet into the earth
devices are prevalent. Such damage can be produced beyond the work area floor slab with approximately
by Electrostatic Discharge (ESD) due to improper six inches exposed for making connection. Dry soil
handling or installation. All MaS/CMOS devices are conditions may require a copper sulfate drip. Electrical
susceptible to damage by the discharge of electrostatic grounds shall be isolated from static grounds.
energy between any two pins. This sensitivity to static
charge is due to the fact that gate input capacitance (5 Water pipes offer convenient grounds; however, they
picofarads typical) in parallel with an extremely high may not be connected to earth ground. These
input resistance (10 12 ohms typical) lends itself to a techniques are for minimizing the difference of
high input impedance and hence readily builds up the potential between separate grounds, and not for
electrostatic charges. reducing the ohmic resistance to earth.

xiii
SAFETY SUMMARY 816R-2C

(This Page Intentionally Left Blank)

xiv
816R-2C GENERAL DESCRIPTION

SECTION 1 - GENERAL DESCRIPTION

4CXI5,OOOA tube operated class C. The output of the


WARNING power amplifier is applied to a 50-ohm unbalanced load.
Power control circuits monitor the RF output power level.
DISCONNECT PRIMARY POWER When a change in output power is detected, these circuits
BEFORE SERVICING THIS change the plate voltage to compensate. Other control
TRANSMITTER. SHORT ALL circuits within the transmitter monitor reflected power,
CAPACITORS AND POWER forward power, operating voltage, air pressure and exhaust
SUPPLIES WITH GROUNDING air temperature within the power amplifier section. They
STICK. VOLTAGES IN THIS protect the transmitter by removing power when excessive
TRANSMITTER ARE DEADLY TO currents, VSWR, loss of air pressure, or excessive air
HUMAN LIFE. exhaust temperature occur.

1-1. INTRODUCTION 1-3. PHYSICAL DESCRIPTION

The 816R-2C transmitter operates in the FM broadcast The transmitter is housed in a unistrut cabinet that contains
range (88-108 MHz) with an RF output power 01'21.5 kW. all transmitter components. Refer to Figure 1-1. The
Reduced power is available by tap changes of the plate and transmitter contains three sections. The section on the left in
screen transformer to meet customer requirements. When Figure 1-1 contains the power amplifier. The center section
the exciter receives input from the optional stereo generator houses the control panel, control circuits, exciter, and driver
and SCA generator, the transmitter provides continuous circuits. The section on the right contains the power
monaural, stereophonic, and SCA (subsidiary supplies, the circuit breakers, and fuse panel.
communication authorization) frequency-modulated
programs. 1-4. TECHNICAL CHARACTERISTICS

Table 1-1 contains the mechanical, environmental, and


1-2. FUNCTIONAL DESCRIPTION electrical specifications for the 816R-2C Transmitter.

The transmitter consists of an exciter, a solid-state driver,


and a power amplifier. The output of the exciter is applied
Ito the driver. The driver consists of two 400-watt modules
combined. The input to the driver is amplified to
approximately 500 watts and applied to the power amplifier
that contains one

Change 5 1-1
GENERAL DESCRIPTION 816R-2C

Cl Cl «) .:) Cl«) C)

Cl«)«)«)«JCl4[)

95G0192

Figure 1-1. 816R-2C FM Transmitter.

1-2 Change 5
816R-2C GENERAL DESCRIPTION

TABLE 1-1. TECHNICAL CHARACTERISTICS

Function Characteristic

MECHANICAL

Weight 1,962 lbs (890 kg)

Size - Transmitter Height: 73 in (188 em) with directional coupler


Width: 70.7 in (180 em)
Depth: 28 in (71 em)

Finish: Front Panel: Grey


Cabinet: Black

ENVIRONMENTAL

Ventilation: Squirrel cage type blower mounted under the cavity. Axial fan in the right
section that provides positive air pressure within the entire cabinet

Ambient Temperature Range: -4°F to + 122°F operating


(-20°C to +50°C)

Relative Humidity Range: ° to 950/0 relative humidity

Altitude: Up to 7,500 ft (2,285m) at 95°F (+35°C)


Up to 10,000 ft (3,046m) at 104°F (+40°C) with optional high altitude blower

Shock and Vibration: Normal handling & transportation

ELECTRICAL

Frequency Range: 88 to 108 MHz

Output Power: 10,000 watts to 21,500 watts

Output Impedance: 50 ohms, unbalanced

Standing Wave Ratio: 2: 1 Maximum (Refer to Figure 3-8)

Power Source: 200 to 250 volts, 60 Hz, 3 phase.


Available voltage taps on plate & screen transformers: 200, 210, 220, 230, 240
and 250. (50 Hz operation available on special order)

Power Line Variations: ±5% overall power line variations; in addition, the phase angle and voltage
unbalance shall be within 5% of the average of all three phases

Change 3 1-3
GENERAL DESCRIPTION 816R-2C

TABLE 1-1. TECHNICAL CHARACTERISTICS - Continued

Function Characteristic

ELECTRICAL - Continued

Harmonic & Spurious Any emission appearing on a frequency removed from the carrier by
Radiation: between 120 kHz and 240 kHz inclusive is attenuated at least 25 dB belo\v the
level of the unmodulated carrier.

Any emission appearing on a frequency removed from the carrier by more than
240 kHz and up to and including 600 kHz is attenuated at least 35 dB below the
level of the unmodulated carrier.

Any emission appearing on a frequency removed from the carrier by more than
600 kHz is attenuated at least 80 dB below the level of the unmodulated carrier.

Modulation Characteristics: Wideband direct FM

Input Power Requirements: 34.5 kW at 0.9 Power Factor


(at 21.5 kW output)

Excitation Source: Continental 802B Exciter

Output Impedance: 50 Ohms, unbalanced

Carrier Frequency Stability: Frequency will not vary more than ±250 Hz for an ambient temperature range of
+32°F to +131°F (0 to +55°C).

Modulation Input: °
Monaural - 600 Ohms, balanced, + 1 dBm ±2 dB, for ±75kHz deviation

Composite - 5,000 Ohms, switchable balanced or unbalanced, 1.25 Vrms, for


±75 kHz deviation

SCA: 3 adjustable, 15,000 Ohms, unbalanced, 1.25 Vrms, for 100/0 injection

Audio Frequency Response: Monaural - ±0.5 dB; flat, 25,50,75 microsecond pre-emphasis, 20 Hz to 15
kHz.

Audio Frequency Distortion: Monaural- Not more than 0.08%,20 Hz to 15 kHz (Measured with spectrum
analyzer)

FM Noise Level: 75 dB below 100% modulation (±75 kHz)

AM Noise Level: Asynchronous - 55 dB below equivalent 100% AM modulation

Synchronous - 50 dB below equivalent 1000/0 AM modulation

1-4
816R-2C INSTALLATION

SECTION 2 - INSTALLATION

2-1. PRE-INSTALLATION INFORMATION 2-1.3.1 Exhaust Fans. There are times when exhaust fans
are the best means of ventilating a transmitter space. If the
The transmitter requires three phase 200 to 250 volts, 50 or room is large and it is not possible to locate the transmitter
60 Hz, AC primary power of either Wye or closed Delta
configuration. Line-to-line balance must be within five
percent both for voltage and phase. near an outside wall, exhaust fans may be the only
reasonable way to ventilate a room. It is better in this
Refer to Figure 2-1 for location of air ports, wire ports, and situation to vent the transmitter directly to the room or
cabinet dimensions. The transmitter should be located to through a short duct to the attic and use exhaust fans in the
allow access to front and rear. room or the attic. It is important to arrange the transmitter
exhaust so that there is no chance of recirculation of exhaust
2-1.1 AC Power. air back into the transmitter.

Figure 2-1 shows the location of the openings in the top and There are many good ways to make an installation utilizing
floor of the transmitter that can be used to bring the power exhaust fans and one method will be described here. If the
cables into the transmitter. Power cables may be brought room has a high ceiling (more than 10 feet), install a drop
through either a two-inch (5 em) knockout in the top of the ceiling about eight feet from the floor. Vent the transmitter
cabinet or through a two-inch round opening in the floor of exhaust directly into the space above the drop ceiling. Let
the transmitter. The size of the power wiring is determined the transmitter take air from the room. At the four corners of
by local electrical code and good engineering practice. In no the drop ceiling install air registers that will allow air from
case should the wiring be smaller than number #1/0 AWG the room to escape into the area above the drop ceiling.
wire where the wire length is up to 100 feet (31 m). The Install an exhaust fan that will evacuate the area above the
disconnect fuses should be 150 ampere slo-blow. The drop ceiling. This method will not have the exhaust fan
transmitter has a 150 ampere primary power disconnect competing with the transmitter fan and blower, will prevent
breaker. recirculation (providing exhaust fan does not fail), and \vill
provide ventilation for the transmitter space. There are
AC line transient suppressors are suggested for the primary variations of this scheme that will allow recirculation
I lines. For recommendation of suppressors, call CE Field (controlled by a thermostat) in the winter to heat the
Service. transmitter space.

2-1.2 RF Output Power. Although exhaust fans and blowers are the most common
method of ventilating transmitter spaces they are not the best
The RF output power termination is a 3-1/8" EIA flange in some cases. The three cautions listed below are some
located at the top of the directional coupler just above the reasons for choosing another method when there is a choice.
PA cavity.
1. An exhaust fan allows unfiltered air into the transmitter
2-1.3 Transmitter Cooling. by expelling air from the room or building and pulling
air into the room through any and all openings in the
In many locations ventilating a building is preferred over air room. The transmitter space should be as clean and dust
conditioning. Air conditioning equipment is mechanical and free as possible. It is not likely that the transmitter space
can break down, is initially expensive, and is expensive to can be air tight except for the filtered air intake. The
maintain and operate. The 816R-2C transmitter can operate unfiltered openings will allow dust and dirt into the
in a room environment where temperatures can be as low as transmitter space.
0
-4 F to as high as 122 F. There are several different ways
0

to ventilate a room that will be discussed in following 2. An exhaust fan results in dead air spaces since it does
paragraphs. Refer to Figure 2-2 for nominal heat balance not "stir" the air in a room which makes "dead air
values. spaces" possible. There is usually only one intended air
inlet to a transmitter space and the air movement is from
that inlet directly to the exhaust fan.

Change 5 2-1
INSTALLATION 816R-2C

2-1.3.1 Exhaust Fans. - Continued duct run is eight feet or less and there are no more than two
elbows, 16 inch round or the equivalent square duct can be
3. In installations where the transmitter is ducted to the connected directly over the transmitter exhaust output using
outside and takes air from the room, the exhaust fan is sheet metal screws. (Dse care when drilling holes for sheet
competing with the transmitter cabinet fan and cavity metal screws so as to avoid metal shavings falling into the
blower for air through the same room air inlet. In this transmitter.) The duct will have to be turned down at the
situation, the greater capacity of the exhaust fan will outside to prevent rain and snow from getting into it. A bell
reduce the transmitter cooling if the room air inlet is not type transition should be used at the end of the duct to
large in size. Where exhaust fans or blowers are used, reduce turbulence.
the room air intake must be large enough so that the
room in not under negative pressure. Negative pressure The duct above the transmitter will have two dampers and
at the transmitter air inlet has the same detrimental effect an opening to the room. The dampers will be motor
as back pressure of the same amount at the transmitter controlled and mechanically linked together so that the
air exhaust. opening to the room will be closed off at the same time that
the air from the transmitter will be directed to the outside.
2-1.3.2 Positive Pressure. Positive pressure ventilation With the dampers in the second position, the air from the
forces air into the room and the air escapes through transmitter will be directed to the room instead of outside.
openings in the room. The air may be forced into the room The mechanical linkage is necessary to prevent the
with propeller type fans or with centrifugal blo\vers. possibility of both dampers being closed at the same time.
Propeller type fans move more air with smaller motors than This arrangement will allow the transmitter to exhaust to the
will centrifugal blowers. A 30 or 36 inch fan is quiet and outside in the summer and recirculate to the inside in the
can move more than 3000 cfm of air into a room and use w·inter.
only a 1/4HP motor. Some of the advantages of positive
pressure ventilation are: A fan that has enough capacity to change the room air at
least once each minute is installed in the wall. This fan pulls
1. All the air entering the room comes through one opening filtered air into the room through motor controlled louvers.
which can be easily filtered. When doors or windows are A 3000 cfm fan will change the air once a minute in a
opened, air moves out through the opening. 15X20 foot room having a 10 foot ceiling.

2. A fan blowing air into a room will "stir" the room air An opening with motor controlled louvers is provided in the
reducing the risk of dead air space. Deflectors at the fan same wall where the fan is mounted. The reason for intake
can be used to direct air into areas that might not fan and room air outlet being on the same wall is to
otherwise have moving air. minimize the effects of wind on the ventilation system. If
both inlet and outlet are on the same wall, the effects of
3. All fans aid each other. The fan that is forcing air into a wind, regardless of direction, is neutralized since the wind
room is aiding the transmitter fans in cooling the pressure is the same on both. The transmitter air exhaust
transmitter. All the fans, the room fan, the transmitter should be on this wall also. The transmitter exhaust should
cabinet fan, and the power amplifier cavity blower are not be positioned so that there is a risk of recirculation.
moving the air in the same direction through the
transmitter. With motor control on inlet and outlet louvers and
transmitter duct dampers, it is possible to control the
4. Like the exhaust system, the pressure system will also operation of louvers, dampers, and the ventilation fan with
ventilate the room. The transmitter will exhaust about thermostats. Set the thermostats, based on environmental
500 cu- ft/min. of air to the outside. If the room fan is conditions, to maintain the required equipment operating
capable of moving three or four thousand cu- ft/min. of temperature at all times. Three conditions are described
air into the room, another opening in the room must be belo\v that will give different results:
provided for room ventilation.

An example of positive room ventilation will be described


here. This is intended only as an example and can be
modified to meet your particular requirements.

Locate the left end or the rear of the transmitter near an


outside wall in order to keep the exhaust ductwork as short
as possible. Position the transmitter so that the exhaust duct
will not interfere with the coaxial RF output line. If the total

2-2
·816R-2C INSTALLATION
3-1/8 fUNGEO OUTP\IT l"RANSUlSSlON UN( CONNECTION HOlES If ROOf" fOR POWER AND REMOTE WIRES

7.O\f 0tA. ruoc EXHAUST


NOT£: Nf(. DUCT WORK MUST NOT REPRES£NT
IAOR( THAN 0.1- WATER 8N)( PRESSURE

00000 0 r- ~.906

1:==27.0~1
2.00 rrP
f /4- 20 CNO HOltS, SlOT FOR

4.406-1 I 6 PlACES GROUND STRAP

26.625
L ~i-------r+-+-----~-----+-t--r'1
4.00
20.375 ++

9.000
-r CONDUIT flTTlN(;
fOR WJN POWER

~12.656
!----H.031
TOP VIEW OF TRANSMITTER
SEE 0(T,6JL A fOR OIUENS1QNS
FLOOR OF TRANSMITIER

~.620
t
-j 11.-406 ($lOE: PANEl.)

"l a ;:;
~
OJ OJ
~ 10 n
(0 (0
~ C'( ('f ('f
V'! n
..; ~
~ ~ ~ ~ "l
- ....: -i-

- 4 -_ _- - + - - + - - 4.312
6.625
r----yL.-.-------"'r-;----t---i~-

CfRCUrr BREAKER ASSY


.812 0tA

1.062 OtA. 3 HOlES


2.375 0lA. 2 HOLES
PA CAVl1Y /4SSY

CONTROl P,A.NU ASSY

68.875
' - - - - - - - - - - - - ' - - - + - - 1 - - 23.1 ..... 1

DETAIL A

lPA ASS'(

r -.-----, o.alNET AIR EXHAUST ON REAR PANEl.

I :
I
Il .J
I

~--------------m~~~~~--------------.~1
FRONT. ·VIEW OF TRANSMITIER

Figure 2-1. FM Transmitter Outline and Installation Drawing

:~2-3/(2.4 Blank).
816R-2C INSTALLATION

CFM \T7 RF
i
HEAT
t OUTPUT
POWER

CABINET
TRANSMITTER HEAT
CABINET
RADIATION
AIR
(CHR)
LEAKAGE
(CAL)

~
AIR-IN INPUT
POWER
STRAY HEAT TO ROOM
~ (CAL) + (CHR)

Power and Cooling 816R-2C


Pwr Out Pwr In Input Stack Stack Stray Room
kW kW kVa Heat, BTU *Temp~ F Heat, BTU

21.5 34.5 36.7 38,560 71.4 5,666


20.0 32.1 34.9 36,519 67.4 5,171
18.0 28.75 31.25 32,424 60.2 4,437
16.0 26.25 27.9 30,717 56.9 4,250
14.0 23.5 24.9 28,328 52.4 4,096
12.0 20.5 22.8 25,598 50.2 3,413
10.0 18.75 20.4 26,280 48.3 3,413

* Rise Above Ambient


Air Input at Cabinet Fan 815 cfm 93G0280A

Stack Air Output 500 cfm


Optimum Ambient Temperature 0
72 F
0
Maximum Ambient Temperature 122 F

Figure 2-2. FM Transmitter Nominal Heat Balance

2-5
INSTALLATION 816R-2C

2-1.3.2 Positive Pressure. - Continued exhaust will be vented to the outside and transmitter will
take air from the room. Since the transmitter will exhaust to
1. A condition of maximum ventilation and cooling will the outside, the exhaust vent on the transmitter should be
result during the hottest periods. The transmitter will be placed as close as possible to an outside wall. Although it is
ducted to the outside and the intake fan will be running. highly undesirable, it is possible to exhaust through the roof
The outlet wall louvers will also be opened to permit but extreme care must be used to weatherproof and leak
room ventilation. proof the ductwork above the transmitter. Since water that
may leak at the ductwork will likely get into the transmitter,
2. A condition of minimum ventilation will exist at times it is absolutely necessary to check for leak proofing often. In
when it is not necessary to run the room intake fan, but any case the ducts must be kept as short as possible to
the transmitter should be vented to the outside. Under minimize back pressure at the transmitter outlet. Remember
these conditions the transmitter exhaust dampers will that elbows, vent caps, and hoods all add extra resistance to
direct the transmitter exhaust to the outside, the outlet air flow through the transmitter. In most installations, the
wall louvers will be closed, the fan will be off, and the transmitter can be placed so that no more than eight feet of
inlet fan louvers will be open to allow fresh filtered air exhaust duct is needed. If this is possible, 16 inch round
into the room and transmitter. duct or the equivalent rectangular duct will be acceptable.
Do not use more than two elbows. It is not a good practice
3. A condition of recirculation for heating will exist during to connect more than one transmitter to the same exhaust
cold periods. The transmitter exhaust dampers will be duct. Let each transmitter have its own individual exhaust
positioned to allow transmitter exhaust air into the room duct.
and all outside outlets and inlets will be closed.
Where possible use large ductwork instead of duct fans.
The system described will require two heating type Duct fans may be required if the duct run is long but duct
thermostats and control relays. One will be set to fans increase air resistance if they fail; therefore, some
approximatel y 65 ° F and the second will be set to method of monitoring and interlocking to the transmitter
approximately 85° F. must be used if there is no alternative to the use of duct fans.

At temperatures above 85 ° F, the first condition described


above will exist. 2-2. UNPACKING AND INSPECTING

For temperatures between 65 ° F and 85 ° F the second 2-2.1 Domestic Shipments.


condition described above will exist.
The uncrated transmitter cabinet is shipped on a shipping
For temperatures below 65 ° F the third condition described skid. The transmitter is attached to the skid by shipping
above will exist. bands. Inspect for loose screws and fasteners. Ensure all
controls operate freely. Examine the cabinet for dents or
The thermostats should be mounted approximately seven scratches. Ensure cable and wiring connections are tight and
feet off the floor and in an area of the room where the situated clear of obstructions.
temperature is not influenced by heat radiated by the
transmitter or by direct air flow from the room intake fan. If any item is freight damaged, the customer should accept
the equipment, note the damage on the shipping documents
The transmitter space should also be provided with a and immediately file a freight claim. All boxes and packing
thermostatically controlled heater that can be set to material should be retained for the freight inspector. Refusal
approximately 50° F. This will provide heat during to accept delivery of damaged equipment removes the
maintenance periods or during times that the transmitter is evidence and makes freight damage reimbursement
off-the-air, if not a 24 hour operation. complicated or impossible.

2-1.3.3 Transmitter Exhaust Duct. Regardless which air 2-2.2 International Shipments.
system is used, careful consideration must be given to
location of transmitter, air intake, and air outlet vent when The transmitter is shipped in a skid type crate with
using outside air for cooling room and equipment. First, unpacking instructions stenciled on the side. Heavy iron
consider where to place the transmitter. The transmitter components are crated separately, bolted down to a 2-inch

2-6
816R-2C INSTALLATION

2-2.2 International Shipments. - Continued 4. Install the 802B Exciter by performing the following
steps:
(5 cm) solid base. Uncrate the transmitter carefully to avoid
damage. Inspect for loose screws and fasteners. Ensure that a. If the 802B Exciter was not factory installed, mount
all controls operate freely. Examine the cabinet for dents or it in the area provided in the transmitter center
scratches. Ensure cable and wiring connections are tight, section. Connect an RF cable from the exciter
and situated clear of obstructions. output to the driver input (A3ARl). Attach the
MUTE voltage leads to A4TB 1-9 and attach power
File any damage claims properly with the transportation control leads to TB 1-8 with shield connected to
company. Retain all packing material if a claim is filed. TB 1-4.. Connect the ac power cable to the exciter.
Refer to the 802B Exciter instruction book for
installation of audio input cables.
2-3. ASSEMBLY
b. If the 802B Exciter is to be mounted separately from
The transmitter has been tested and prepared for shipment at the transmitter, make sure the voltage source
the factory. Perform the following steps to reduce matches the voltage on the voltage selector card at
installation time. the rear of the exciter. Refer to the 802B Exciter
manual for ac power installation. rrhe exciter mute
1. Plan the placement of the transmitter and its external voltage must also be connected to the 802B Exciter
wiring carefully before beginning installation. Refer to TB 1-9 and attach power control leads to TB 1-8 with
Figure 2-1. Six knockout holes are located on the top of shield connected to TB 1-4. The RF output from J3
the transmitter section that contains the power supplies. of the 802B Exciter will be connected to the Driver
The holes accommodate cabling for 3-phase input RF input (A3AR1) using RG-223 cable or
voltage and the remote control wiring. A 2-inch (5 cm) equivalent.
conduit entry is also provided in the floor of the power
supply section. 5. Transformers T1 and T2, filters L1 and L2, and filter
capacitor C 1 may have been removed to facilitate
shipping. Install these components if they were shipped
WARNING separately.

ALWAYS CONNECT THE TRANSMITTER 6. Install the PA tube using the procedure outlined in
TO STATION GROUND PRIOR TO paragraph 5-5.1
CONNECTING AC VOLTAGE TO THE UNIT.
FAILURE TO COMPLY WITH THIS 7. If remote control is used, run the external wiring from
WARNING MAY RESULT IN PERSONNEL the remote unit into the transmitter and connect it as
INJURY. shown on Figures 2-3 and 2-4.

NOTE
2. Connect the transmitter to the station ground system
using 4-inch copper strap. Holes are provided for this The positive plate current sample, AIOTB2-9
purpose in the floor of the transmitter. must be connected to the ground side of the
remote metering circuits if one side of the remote
3. Connect the input power wiring from the customer metering is grounded. The negative plate current
supplied fuse or circuit breaker panel with a 150 ampere sample AIOTB2-8 will then be connected to the
rating. Using a #1/0 AWG cable, (follow local remote metering input. The open circuit voltage
"Electrical Code" to determine wire size for a 150 at AIOTB2-8, -9 will be approximately 7.2 V dc
ampere fused service) connect 3-phase power to when plate current is 3.0 amperes. An external
transmitter terminal board A8TB 1. Connect the power voltage divider may be required to obtain a
AC GND to the GND terminal adjacent to A8TBI. Do sample that is within allowable limits for the
not tum on power at this time. remote control. Refer to Figure 2-5.

2-7
INSTALLATION 816R-2C

CUSTOMER CUSTOMER
FURNISHED FURNISHED
REMOTE CONTROL CABLE TRANSMITTER

~A-----... _-_A_-_ ~A-


/' THIS SWITCH MUST REMAIN '" ~ ~./ ~
CLOSED TO MAINTAIN
SECOND POWER LEVEL
A10TB2

2nd PWR LVL

FIL ON IND

FIL OFF IND

RMT INTLK
RMT INTLK
REMOTE PANEL
PLT ON IND
CONNECTIONS
FOR LAMP MAY RMT COM
BE RELAY
CIRCUITS PA Ip (-)

PA Ip(+)

10 PA Ep (-)

RMT 11 PA Ep(+)
METERING
12 REFL PWR

13 FWD PWR

14 GND
15 GND

16 +24

17 +24

A10A2TB1

PLT OFF

PLT ON

FIL OFF

---------&---------+-------~
4 FIL ON

GND

6 +24

FAILSAFE

MAN. PWR R

MAN. PWR L

- - - - - - - - - = : . - - - - - - - - - - - - - - - - . , 10 AUTO PWR CO NT

--------=:..----------------., 11 MAN. PWR CO NT

12 NOT USED

CONTROL METER
CHANNEL FUNCTION
FUNCTION

1 FIL OFF/ON 93G0281A

2 PLATE OFF/ON PLATE VOLTS


3 MANUAL/AUTO PLATE CURRENT
4 PWR RAISE/LOWER FWDPWR
5 REFL PWR

TYPICAL REMOTE CONTROL CHANNEL ASSIGNMENT

Figure 2-3. Remote Control Connections

2-8 Change 5
816R-2C INSTALLATION

CUSTOMER
FURNISHED
CABLE
TRANSMITTER

TB3* A10TB1

1, 11 'lI1 1
} PLATE ON
2, 12 2
3, 13 3
4, 14 4
} EXT INTLK
3770-1 5, 15 5 PL ON TALLY
3770-2 6, 16 6 PL OFF TALLY
7, 17 ~
7 GNO
..l-
8, 18 - 8 +24V
9, 19 9
10,20 } PL OFF
10

93G0239

*
TERMINALS 1 - 10 ARE FOR TRANSMITTER NO.1
TERMINALS 11 -20 ARE FOR TRANSMITTER NO.2

Figure 2-4. Transmitter Controller (377D-l or -2) Connections

Change 5 2-9
INSTALLATION 816R-2C

0.25 OHM
A10TB2 1.2K 10W
A5A 1R 11 A5A1R9
*6.8K
1W
- 8

REMOTE 36K
CONTROL * 2.7K 1W
METERING A5A1R12

9
+ 1.2K
1W
4 OHM
100W
~
36W
A5A1R13 A5R8 A5R6

10HM
* A5R5
CUSTOMER SUPPLIED

93G0283

Figure 2-5.. Remote Plate Current Sample Circuit

2-10
816R-2C INSTALLATION

2-3. ASSEMBLY - Continued 9. The transmitter is shipped with all transformers on the
highest voltage taps unless specific instructions are
given regarding source line voltage. This is done to
CAUTION prevent damage where line voltage may be higher than
transformers are tapped for and power is applied
ENSURE THAT THE TRANSMISSION LINE without changing taps.
AND ANTENNA PRESENT A 50 OHM
IMPEDANCE AND A VSWR NOT GREATER The broad range of allowable voltage sources (200 to
THAN 2:1 TO THE TRANSMITTER AT THE 250 volts) is made possible by the availability of
OPERATING FREQUENCY. DAMAGE MAY different primary tap connections of power transformers
RESULT FROM AN IMPROPER IMPEDANCE T1, T2, T3, and A 1OTl. Figures 2-6 and 2-7, and Table
MATCH BETWEEN THE TRANSMITTER 2-1 show the details of the proper primary line
AND THE RF SWITCH, TEST LOAD, OR connections for various source line voltages. Figures 2-8
TRANSMISSION LINE. shows the proper T2 secondary line connections for
various input line voltages.
8. Connect the customer-supplied, 50-ohm transmission
line to the RF output connector mounted on top of the In addition to the primary taps, the screen transfonner
transmitter cabinet. (T2) has three sets of secondary taps. These secondary
taps are identified as 1000/0, 850/0, and 700/0. The DC
screen voltage will be 800 volts when the primary taps
match the source line voltage and the secondary leads
CAUTION are connected to the 1000/0 taps. For example if the
secondary leads are moved to the 700/0 taps the DC
FOR 60 HZ OPERATION ONLY, THE screen voltage will be lowered to 560 volts.
TRANSFORMER PRIMARY TAPS MUST
NOT BE SET MORE THAN TWO TAPS
LOWER THAN THE HIGHEST LINE
VOLTAGE EXPECTED. FOR EXAMPLE, IF
LINE VOLTAGE IS 245 VOLTS, THE SCREEN
TRANSFORMER PRIMARY TAPS CAN BE
SET TO THE 230, 240, OR 250 VOLT TAPS. IF
LINE VOLTAGE IS 240 VOLTS, THE SCREEN
TRANSFORMER COULD BE SET TO THE 220
VOLT TAPS IF NECESSARY TO INCREASE
TRANSMITTER POWER. TRANSFORMER
TAPS SHALL NOT BE SET TO LOWER TAPS
THAN THE HIGHEST EXPECTED LINE
VOLTAGE WHERE 50 HZ PRIMARY POWER
SOURCE IS USED. FAILURE TO COMPLY
MAY RESULT IN DAMAGE TO EQUIPMENT.

2-11
INSTALLATION 816R-2C

A6
A8TB1
CB6

3
Pia
CB5 3
r

LINE T1,T2 A10T1 TERM.


VOLTAGE TERMINALS CONNECTION

200V 2&3, 7&8, 12&13 1 &2


210V 2&4,7&9, 12&14 1 &2
220V 2&5,7&10,12&15 1 &2
230V 1&3, 6&8, 11 &13 1 &3
240V 1&4,6&9,11&14 1 &3
250V 1&5,6&10,11&15 1 &3

T1 - PLATE TRANSFORMER

T2 - SCREEN TRANSFORMER

A 1OT1 - PA BIAS SUPPLY 94G0051

Figure 2-6. Transformer Connection Schedule.

2-12
816R-2C INSTALLATION

EB
EB
24 Volt Power Supply
EB A10PS1
EB
EB
EB NOTE: Depending on supply voltage,
EB connect AC voltage to A10PS1
{f) as shown.
I
22 ov
rI\
I ~
t0 190V rI\
25 OV to Q7
220V
I I I

AC Voltage Connections

T3

-o00------~ ~
o:~~.&
3 6 2 ~ 5 2 ~ [} --.,
~ 10

0
- 0 .:0 ------0~
: ~:~.
2 ~ 5 3 ~6 3 ~
A6CB6 A6CB3 ~ 11
AC LINE DRIVER
POWER
SUPPLY
I I
A5K1

00G0007

Figure 2-7. Driver Transformer (T3) Connection.

Change 4 2-13
INSTALLATION 816R-2C

TABLE 2-1. Screen Voltage Transformer Tap Schedule

Primary Line Voltage


Configuration Taps 200 210 220 230 240 250

DC SCREEN VOLTAGE

100 % WYE 200 800 840 880


210 762 800 838 876
220 727 764 800 836 873
230 696 730 765 800 835 870
240 667 700 733 767 800 833
250 640 672 704 736 768 800

85 % WYE 200 680 714 748


210 648 680 712 745
220 618 649 680 711 742
230 591 621 650 680 710 739
240 567 595 623 652 680 708
250 544 571 598 625 653 680

70 % WYE 200 560 588 616


210 533 560 587 613
220 509 535 560 585 611
230 487 511 536 560 584 609
240 467 490 513 537 560 583
250 448 470 493 515 538 560

100 % DELTA 200 462 485 508


210 440 462 484 506
220 420 441 462 483 504
230 402 422 442 462 482 502
240 385 404 424 443 462 481
250 370 388 407 425 444 462

2-14
816R-2C INSTALLATION

TO SCREEN RECTIFIER

/0 0 0
/ /
/ / \ / / \ / / \
/
/ / \ /
/ / \ / / / \
008
100% 85% 70%
000
100% 85% 70%
000
100% 85% 70%

JUMPER JUMPER

SCREEN SECONDARY WYE CONNECTION

TO SCREEN RECTIFIER

100% 85% 70% 100% 85% 70% 100% 85% 70%

00cp
,\
41
000
I \ /
33
000
I\ /
37

\ I / \ I / \ I /
\ / \ / \ /
0 a 0

SCREEN SECONDARY DELTA CONNECTION

95G0242

Figure 2-8. Secondary Tap Configuration, T2.

2-15
INSTALLATION 816R-2C

(This Page Intentionally Left Blank)

2-16
816R-2C OPERATION

SECTION 3 - OPERATION

3-1. GENERAL 6. Set the 24 VDC POWER SUPPLY and BLOWERS I


circuit breakers to ON. Check the PHASE LOSS
The transmitter may be operated from the local control indicator on the Al Control Panel (see Figure 3-2). If
panel or by remote control. Once the transmitter has been this indicator is not on, set AC LINE circuit breaker to
installed and properly tuned, it is only necessary to monitor OFF. Remove the right front bay access panel. Locate
meter indications and to make periodic minor tuning and A8K5 (the phase loss/phase rotation monitor) and tum
loading adjustments. Instructions for the 802B exciter are its control to minimum (full counterclockwise). Install
found in the Exciter Instruction Manual. the access panel and restore primary power. If the
PHASE LOSS indicator is still not on, shut off primary
3-2. CONTROLS AND INDICATORS power and disconnect power from power input lines.
Interchange any two primary input leads at A8TB 1
Refer to the following figures and tables for a general (Figure 6-18). Restore primary power and check
description of the operating controls found on the front indicator.
panels of the transmitter. Figure 3-1 shows the location of
the control and indicator panels. Figures 3-2 through 3-5 7. Adjust the Phase Monitor A8K5 phase loss threshold.
show details of each panel. Tables 3-1 through 3-4
supplement Figures 3-2 through 3-5.
WARNING
The PA grid tuning control is part of Power Amplifier
Cavity A 12. The control shaft extends through a hole in a HIGH VOLTAGES ARE EXPOSED WHEN
structural panel. The control knob is shown in Figure 3-1. CABINET DOORS OR ACCESS PANELS ARE
This control allows adjustment ofPA grid circuit resonance. OPENED. DEATH ON CONTACT MAY
OCCUR. BE CAREFUL WHEN
3-3. INITIAL TURN-ON PROCEDURE PERFORMING THE FOLLOWING
PROCEDURES.

WARNING a. Set AC LINE circuit breaker to OFF and remove


the right front bay access panel.
DISCONNECT PRIMARY POWER BEFORE
SERVICING THIS TRANSMITTER. SHORT b. Block the interlock grounding switch, on the right
ALL CAPACITORS AND POWER SUPPLIES front bay access panel, in the open position.
WITH GROUNDING STICK. VOLTAGES IN
THIS TRANSMITTER ARE DEADLY. NOTE

1. Ensure transmitter has been assembled and connected The phase loss/phase rotation monitor will shut
according to instructions in Paragraphs 2-1 through 2-3. the transmitter off when phase loss or incorrect
sequence is detected. A phase loss will be
2. Remove access panel of Card Cage Assembly for detected if the line voltage drops below the
access to the control circuit cards. Check the circuit threshold voltage level which is set by turning
cards for proper installation. the control on K5. The threshold voltage range is
190-270V and it must be set below the lowest
3. Install Card Cage access panel and ensure all doors and expected line voltage. To accomplish this, the
panels are properly closed or installed. line voltage should be at the lowest expected
level when performing the following adjustmento
4. Ensure all transmitter circuit breakers on A6 panel are
OFF.
Continued on Page 3-12.
5. Connect primary power to transmitter and set AC LINE
circuit breaker to ON.

Change 5 3-1
OPERATION 816R-2C

CIRCUIT
CONTROL BREAKER
PANEL, A1 CARD CAGE, A2 PANEL, A6
FIG. 3-2 FIG. 3-3 FIG 3-5

/
/
/ o

• • • • 0 • •

! [Jrn~QiJJ 0 •• 0 • 0 0 0 0

i 0- IF?? ~o

~~ I~~
~
I

I
I \
I \
I
PA GRID TUNING IPA, A3
\
EXCITER, A4
93G0286

PIa PA CAVITY, FIG. 3-4 (REF 802B)


A12C2

Figure 3-1. Transmitter Control Panels.

3-2 Change 5
816R-2C OPERATION

2 3 4

MULTIMETER PLATE VOLTAGE PLATE CURRENT


POVVER OUTPUT

o 28VSUPPLY
4O'1F8 00 RAISE lOWER
o PA SCREEN CURRENT
IlOOIoIN'll POWER ADJUST
-- POWER-

o PA GRID CURRENT

G-UMrr-O 0- UMrrO
o
o
PASCREENVOLTAGE
1lOO'IF8

PABlAS

-
RAISE lOWER
TUNING-
o
-
RAISE LOWER
LOADING -

22 17 16 15 14 13 12 23

REFL FWD

-- POWER - -
POWER ADJUST
10
5

11

21

9
18

19 20 8 7 93G0287

Figure 3-2. Control Panel, AI, Controls (Sheet 1 of 2).

3-3
OPERATION 816R-2C

o~~~~o
[ ~2 9~~ 9~~ ]~ :-0-:
o-lIlIf""0

_
0.-- 0 _ 0-LMr0

0"....
0...........
0--
0 .........
0 __ DD DD l-'-_~

- -- -~- <:::)

(0 .....- 0-- ) =0
0-
_

STATUS
o PHASE LOSS o RMT PLT OFF INTLK o R REAR DOOR INTLK 0 PA SCRN OVLD

o CARD CAGE INTLK o PA GRID DOOR INTLK 0 C FRONT PNL INTLK 0 PA PLATE OVLD

o AIR INTLK o PA DOOR INTLK o R FRONT PNL INTLK OVSWROVLD

o TEMP INTLK o o
o READY

(o
o
L REAR DOOR INTLK

C REAR DOOR INTLK o


o
REMOTE INTLK

FAILSAFE INTLK
OVLD
STATUS
RESET
D
LOCAL CONTROL REMOTE CONTROL
J
93G0288A

Figure 3-20 Control Panel, AI, Status Indicators (Sheet 2 of 2)$

3-4
816R-2C OPERATION

Table 3-1. Control Panel, AI, Controls and Indicators

Index Control or
No. Indicator Function

TEST METER AIMI Displays voltages and currents selected by meter select switches.

2 PLATE VOLTAGE AIM2 Displays power amplifier plate voltage.

3 PLATE CURRENT meter Al M3 Displays power amplifier plate current.

4 POWER OUTPUT meter AIM4 Displays power amplifier forward or reflected power as selected by
POWER switch.

5 POWER FWD-REFL Allows selection of power amplifier forward power at 120% full scale
switch AIAlS9 or reflected power at 120/0 full scale for display on POWER OUTPUT
meter.

6 LOADING LOWER LIMIT Lights when lower limit is reached with LOADING
indicator AIAIDS29 LOWER switch being held.

7 LOADING RAISE LIMIT Lights when upper limit is reached with LOADING RAISE
indicator AIAIDS28 switch being held.

8 LOADING RAISE Pushbutton momentary switch that allows the variable PA


switch AIAlS12 loading capacitance to be raised.

9 LOADING LOWER switch Pushbutton momentary switch that allows the variable PA
AIAlS13 loading capacitance to be lowered.

10 POWER ADJUST RAISE Pushbutton momentary switch that allows the power amplifier output
switch AIAlS7 to be raised.

11 POWER ADJUST LOWER Pushbutton momentary switch that allows the power amplifier output
switch AIAlS8 to be lowered.

12 PLATE ON switch AIA1S6 Pushbutton switch-indicator for application of plate voltage to power
amplifier.

13 PLATE OFF switch A1A1S5 Pushbutton switch-indicator for removal of plate voltage from power
amplifier.

14 FILAMENT ON switch AIAlS4 Pushbutton switch-indicator for application of filament voltage to


power amplifier.

15 FILAMENT OFF switch A 1A 1S3 Pushbutton switch-indicator for removal of filament voltage from power
amplifier.

16 POWER CONTROL MAN Pushbutton switch-indicator that allows selection of manual


switch A1A1S2 power amplifier output control.

3-5
OPERATION 816R-2C

Table 3-1. Control Panel, AI, Controls and Indicators - Continued

Index Control or
No. Indicator Function

17 POWER CONTROL AUTO Pushbutton switch-indicator that allows selection of automatic


switch AIAlSl power amplifier output control.

18 TUNING RAISE Pushbutton momentary switch that allows the variable PA


switch AIAlSI0 tuning capacitance to be raised.

19 TUNING LOWER Pushbutton momentary switch that allows the variable PA


switch AIAlS11 tuning capacitance to be lowered.

20 TUNING LOWER LIMIT Lights when lower limit is reached with TUNING LOWER
indicator AIAIDS27 switch being held.

21 TUNING UPPER LIMIT Lights when upper limit is reached with TUNING RAISE
indicator AIAIDS26 switch being held.

22 METER SELECT Allows selection of voltages and currents to be displayed on TEST


switches AIA1S14 & SIS METER. Value listed below each selection is full scale value.

23 RESET switch AIAlS16 Pushbutton momentary switch that resets fault indicators.

STATUS Indicators: (See Figure 3-2, Sheet 2 for close-up of status section of panel)

NOTE: During normal operating conditions "OVLD" indicators


are OFF. READY, PHASE LOSS, and all INTLK
indicators are ON.

PHASE LOSS, AIA1DS6 Lights when all phases, phase sequence, and phase balance is correct.

CARD CAGE INTLK, AIAIDS7 Lights when interlock circuit is normal.

AIR INTLK, A 1A 1DS8 Lights when there is adequate air pressure.

TEMP INTLK, AIAIDS9 Goes out when exhaust temperature is too hot.

READY, AIAIDSI0 Lights to indicate completion of PA filament warmup time delay.

RMT PLT OFF INTLK, Remote plate off relay indicator.


AIAIDSII

PA GRID DOOR INTLK, PA grid door interlock indicator.


AIAIDS12

PA DOOR INTLK, AIAIDS13 PA door interlock indicator.

L REAR DOOR INTLK, Left rear door interlock indicator.


AIAIDS14

3-6
816R-2C OPERATION

Table 3-1. Control Panel, AI, Controls and Indicators - Continued

Index Control or
No. Indicator Function

C REAR DOOR INTLK, Center rear door interlock indicator.


AIAIDS15

R REAR DOOR INTLK, Right rear door interlock indicator.


AIAIDS17

C FRONT PNL INTLK, Center front panel interlock indicator.


AIAIDS18

R FRONT PNL INTLK, Right front panel interlock indicator.


AIAIDS19

REMOTE INTLK, AIDS20 Remote interlock indicator.

FAILSAFE INTLK, A 1A 1DS21 Remote failsafe relay interlock indicator.

PA SCRN OVLD, AIAIDS23 PA screen fault indicator.

PA PLATE OVLD, AIAIDS24 PA plate fault indicator.

VSWR OVLD, AIAIDS25 VSWR fault indicator.

LOCAL CONTROL, AIAIDS16 A2S2locai control position indicator.

MANUALPWRCONTROL A2S 1 Remote control position indicator.


AIAIDS22

3-7
OPERATION 816R-2C

2 5

o FIL

VOLTS OA-B
OB-C
METER LOCAL REMOTE
OC-A
SELECT

AC VOLTMETER FILAMENT HOURS

93G0288

Figure 3-3. Card Cage Assembly, A2, Controls and Indicators

2 3 4 5 6 7

" \ I / /
POWER
AMPERES

VSWR Ee Ie FWD REFL


60 30 1200 1200
VFS AFS WFS WFS

93G0289A

Figure 3-4. IPA, A3, Controls and Indicators

3-8 Change 5
816R-2C OPERATION

Table 3-2. Card Cage Assembly, A2, Controls and Indicators

Index Control or
No. Indicator Function

AC VOLTS meter A2Ml Display voltage selected by AC VOLTMETER switch.

2 AC volt meter switch A2A7S3 Selects line voltage or filament voltage displayed on AC volt meter.

3 LOCAL switch A2A 782 Allows selection of local control of power amplifier operations.

4 REMOTE switch A2A7S 1 Allows selection of remote control of power amplifier operation.

5 HOURS meter A2M2 Transmitter operation elapse time recorder.

6 Door Interlock Switch Indicates the card cage door is open and prevents application of
A2S2 filament voltage to the tube stage.

Table 3-3. IPA, A3, Controls and Indicators

Index Control or
No. Indicator Function

VSWR indicator A3A2DS2 Lights to show high reflected power on IPA.

2 POWER indicator A3A2DS 1 Lights to show that IPA is on.

3 Meter function selector s\vitch Pushbutton switch allows selection of IPA collector voltage
plo A3AlSl to be displayed on panel meter A3Ml.

4 Meter function selector switch Pushbutton switch allows selection of IPA collector current
plo A3AISI to be displayed on panel meter A3Ml.

5 Meter function selector switch Pushbutton switch allows selection of IPA FWD power
plo A3AISI to be displayed on panel meter A3Ml.

6 Meter function selector switch Pushbutton switch allows selection of IPA REFL power
plo A3AISI to be displayed on panel meter A3M 1.

7 Multiple display meter Displays voltage, current, or power selected at panel's selector
A3Ml switch.

Change 5 3-9
OPERATION 816R-2C

20

3 C)

2
AC LINE
C)

5
PA PLATE
POWER SUPPLY
28V DC DRIVER PA SCREEN
POWER SUPPLY BLOWERS (9 (9
POWER SUPPLY POWER SUPPLY
e ~ e e ~ e ~ e

C)
H8B
$ CD
C)

PA BIAS PA BIAS
FAN FAN POWER SUPPLY POWER SUPPLY FILAMENTS

((J) (0) (Q)


F7 F1
7

C)

19
93G0290

18 17 16 15 14 13 12 11 10 9 8

Figure 3-5.. Circuit Breaker Panel, A6, Controls and Indicators

3-10
816R-2C OPERATION

Table 3-4. Circuit Breaker Panel, A6, Controls and Indicators

Index Control or Function


No. Indicator

28 VDC POWER.. SUPPLY ON/OFF control and protection for 24V de power supply.
circuit breaker A6CB 1

2 BLOWER circuit breaker ON/OFF control and protection for transmitter cavity blower
A6CB2 and cabinet fan.

3 DRlVER POWER SUPPLY ON/OFF control and protection for driver (IPA) power supply.
circuit breaker A6CB3

4 PA SCREEN POWER SUPPLY ON/OFF control and protection for power amplifier screen power
circuit breaker A6CB4 supply.

5 PA PLATE POWER SUPPLY ON/OFF control and protection for power amplifier plate power
circuit breaker A6CB5 supply.

6 FILAMENTS fuse A6Fl Power amplifier filament circuit protector.

7 CONTROLS fuse A6F14 Control motors circuit protector.

8 FILAMENTS fuse A6F3 Power amplifier filament circuit protector.

9 FILAMENT METER fuse A6F 13 'Power amplifier filament current metering circuit protector.

10 PA BIAS POWER SUPPLY Power amplifier grid bias power supply circuit protector.
fuse A6F5

11 EXCITER fuse A6F2 Exciter power circuit protector.

12 EXCITER fuse A6Fl1 Exciter power circuit protector.

13 PA BIAS POWER SUPPLY Power amplifier grid bias power supply circuit protector.
fuse A6F4

14 POWER CONTROL Protection for primary circuit of A2Tl, T2, and T3.
AMPLIFIER fuse A6FI0

15 FAN fuse A6F12 Protection for cabinet fan AC power circuit.

16 POWER CONTROL Protection for primary circuit of A2Tl, T2, and T3.
AMPIJFIER fuse A6F6

17 FAN fuse A6F9 Protection for cabinet fan AC power circuit.

18 POWER CONTROL Protection for primary circuit of A2Tl, T2, and T3.
AMPLIFIER fuse A6F8

19 FAN fuse A6F7 Protection for cabinet fan AC power circuit.

20 AC LINE circuit breaker A6CB6 ON/OFF control for AC input power to transmitter.

Change 5 3-11
OPERATION 816R-2C

3-3. INITIAL TURN-ON PROCEDURE - Continued ANTENNA WITH A 50-OHM IMPEDANCE OR A


from Page 3-1 DUMMY LOAD CAPABLE OF DISSIPATING AT
LEAST THE RATED RF OUTPUT OF THE
c. Restore primary power. TRANSMITTER.

d. Increase the phase loss threshold voltage by 11. Set all circuit breakers to ON and apply primary power.
turning the control on A8K5 cw until the LED on Press FILAMENT ON switch.
K5 goes out. Tum the control ccw slightly past the
point where the LED comes back on. 12. Set the METER SELECT switches, AIA1S14 & SIS,

NOTE
to 24V SUPPLY (40V SCALE). The test meter will
indicate 24 ±2.0 V de. I
To avoid nuisance phase loss relay activations: 13. Set the METER SELECT switch, A2A7S3, to FIL. The
(a.) On 208 Vac sites adjust K5 completely ccw test meter should indicate 6.0 ±O.l volts. Adjust
to its limit. (b.) On 240 Vac sites adjust K5 filament voltage if it is not correct. Use procedure in
approximately half way between the lamp turn Paragraph 5-7.2. These adjustments are required to be
on and the ccw limit. made at customer's normal line voltage.

e. Remove primary power. NOTE

f. Remove block from interlock grounding switch. Refer to 802B Exciter Instruction Manual for
exciter details.
g. Install access panel.
14. Verify that the exciter is on.

WARNING NOTE

HIGH VOLTAGES ARE EXPOSED WHEN The transmitter is adjusted and pre-tuned at
CABINET DOORS ARE OPENED OR the factory for specific customer power output
ACCESS PANELS ARE REMOVED. DEATH and frequency requirements. In normal
ON CONTACT MAY OCCUR. BE CAREFUL applications, the fine-tuning and adjustment
WHEN PERFORMING THE FOLLOWING procedures provided in Steps 14 through 27 are
PROCEDURES. adequate to ensure proper transmitter
operation. However, if the transmitter is to be
8. Loosen the two retaining bolts at the bottom of the left operated at a frequency or power output
cabinet side panel. Grip the panel securely and lift it different from the frequency or power output
off. designated in the factory test data supplied
with the transmitter, perform the complete RF
9. Apply primary power and press FILAMENT ON tuning and power adjustment procedures listed
switch on PA Power Control Panel. in Paragraphs 5-8 and 5-9.

10. Remove primary power and observe direction of 15. Press the PO\\lER CONTROL switch MANUAL for
rotation of the PA cavity blower and the cabinet fan as manual power control operation.
they come to a stop. Cabinet fan rotation may be
observed by lifting the foam filter from the top right 16. Press the POWER switch to FORWARD.
side of the cabinet. PA cavity blower rotation should be
counterclockwise when viewed from the shaft end. 17. Press the LOCAL switch, A2A7S2. The LOCAL
Cabinet fan rotation should be counterclockwise when CONTROL LED will light.
viewed from the top. Install cabinet side panel.
18. Press the PLATE ON switch. The PLATE ON switch
CAUTION lamp will light.

DO NOT PERFORM THE REMAINDER OF 19. Adjust PA GRID TUNING for minimum IPA reflected
THIS PROCEDURE IF THE TRANS- power.
MITTER IS NOT CONNECTED TO AN

3-12 Change 5
816R-2C OPERATION

3-3. INITIAL TURN-ON PROCEDURE - Continued plate current (not plate current dip). The loading control
is adjusted for maximum RF output. PA screen current
20. Slightly adjust the PA LOADING and PA TUNING decreases when loading is raised and increases when
controls until maximum power output is displayed on loading is lowered. Normally, screen current is between
the POWER OUTPUT meter. 300 - 600 rnA. The screen current is dependent upon
loading, power output requirements, plate and screen
21. As the transmitter warms up, the IPA reflected power voltage, and individual tube characteristics. When the
will rise. Re-tune the PA GRID TUNING as needed to PA tube is replaced, screen voltage may have to be
keep the reflected power below 75 watts (final value is changed in order to obtain the desired power output.
less than 20 watts). Once the IPA reflected power
appears stabilized, repeat Steps 19 & 20. The final 26. MAXIMUM POWER OUTPUT ADJUSTMENT.
setting should be established after the transmitter has
been on for at least 30 minutes. Do not re-tune the grid NOTE
after the final setting has been established.
This procedure is intended to maintain
NOTE authorized station maximum power output with
line voltage variations.
Operating parameters will become stable within
15-20 minutes. All fine tuning and recording of a. Press the RAISE switch of the POWER ADJUST
operating parameters should be performed only control until maximum power output is displayed
after the transmitter has stabilized. on the POWER OUTPUT METER.

22. RAISE or LOWER the POWER ADJUST control until b. If the maximum power output is not more than 5%
the POWER OUTPUT meter displays the station's above the authorized station maximum output, skip
authorized power level. If specified by the customer, to Step h. If the maximum power output is more
the meter was calibrated at the factory to indicate 100% than 5% above the authorized station maximum
at this power. output, proceed to Step c.

23. Compare meter readings with those listed in the factory c. Press the PLATE OFF and FILAMENT OFF
test data located at the back of this manual. If additional switches on control panel AI.
tuning or transformer tap adjustment is required, refer
to the adjustment procedures listed in Paragraph 5-7. d. Tum off primary power to the transmitter.

24. Set POWER CONTROL switch to AUTOMATIC. e. Refer to Figure 2-5 and Table 2-1, and change
Adjust the power monitor/control card A2A6R8, wires to the screen transformer terminals to
located in the card cage, for 1000/0 output power if decrease screen voltage.
necessary.
f. Reapply primary power and press the FILAMENT
25. PA TUNING AND LOADING (For best efficiency). ON and PLATE ON switches on control panel AI.
There is not likely to be a plate current dip within the
normal range of tuning control. There are, however, g. Repeat Steps c through f until the maximum
three indicators to be observed for proper PA TUNE. transmitter output is approximately 5% above the
Power output and screen current will be maximum. PA authorized station maximum output.
plate current will change as the tuning is changed. Plate
current will increase when the tuning control is held in h. Compare the PLATE VOLTAGE reading with the
the raise position. When the shorting plane is plate voltage listed in Tables 3-5 and 3-6 for the
positioned correctly, the PA screen current and power authorized station maximum power output. (Linear
output will go through a peak. Refer to Figure 3-6 for interpolation of tabulated values may be
an indication of what to expect as the tuning control is necessary.) If the compared voltages differ by
run through its total mechanical range, from one limit more than 100/0, proceed to Step i. If the compared
to the other. Notice that power output is the same at voltages differ by less than 10%, skip to Step n.
point A and point B, but that plate current is greater at
point B. The proper tuning point is at point A which
results in maximum output and also the least amount of

3-13
OPERATION 816R-2C

A B
l-
::J
0....
l-
::J
0
0:
W
S
0
0....

LOWER PA TUNING RAISE

l- A B
z
W
0:
a:
:J
0
Z
W
w
a:
U
Cf)
<{
0....

LOWER PA TUNING RAISE

l-
Z
W
0:
a:
::J
o
W
l-
:5
0....
<{
0....

LOWER PA TUNING RAISE

93G0291

Figure 3-6. PA Tuning and Loading

3-14
816R-2C OPERATION

3-3. INITIAL TURN-ON PROCEDURE - Continued

1. S\vitch transmitter to AUTO POWER CONTROL


1. Press the PLATE OFF and FILAMENT OFF mode.
switches on control panel AI.
2. Apply 24 V dc to Al OTB2-1, Remote Control, to I
J. Tum off primary power to the transmitter. activate relay A2A6KI.

k. Refer to Figure 2-5. If the transmitter plate voltage 3. Adjust Power Monitor (Control Card) A2A6R7 for the
exceeds the tabulated voltage, change wires on desired power level.
transformer T 1 to the terminals listed for the next
higher line voltage. If the tabulated voltage
exceeds the transmitter plate voltage, change wires 3-6. AUTOMATIC RECYCLE RESETTING
on transformer T1 to the terminals listed for the
next lower line voltage. Automatic transmitter shutdown occurs when PA Screen,
PA Plate, or VSWR is overloaded. An overload indicator,
1. Repeat Steps h through k until the transmitter and AIAIDS23 through AIAIDS25, illuminates on Control
the tabulated plate voltages differ by less than Panel A 1. The automatic recycling circuits, when enabled,
100/0. restart the transmitter. The indicator lamp remains on until
the transmitter operator presses the FAULT RESET switch
ill. Repeat Step a. on the main control panel. The fault indicator lamp cannot
be RESET from Remote Control location.
n. Adjust the POWER ADJUST controls until the
POWER OUTPUT meter displays the authorized The fault recycling circuits may be tested by using switch
station maximum power output. A2A5SI or disabled by switching the AUTO RECYCLE
switch A2A5S2 to OFF.

NOTE
Use curves and equations in Figure 3-7 for 3-7. NORMAL TURN-OFF (Local)
indirect power output determination.
1. Press the PLATE OFF pushbutton and allo\v a few
seconds for the voltage to decrease.
27. ANTENNA SYSTEM VSWR CHECK. The POWER
OUTPUT meter and the graph in Figure 3-8 can be 2. Press the FILAMENT OFF pushbutton.
used for this purpose if other means are not available.
Typically, VSWR is less than 1.1: 1 and it must not
exceed 2:1. 3-8. EMERGENCY TURN-OFF

In the event of an emergency, remove power in any of the


3-4. REMOTE OPERATION following ways:

Press the REMOTE switch of A2 to begin remote operation. 1. Press the FILAMENT OFF pushbutton.
The REMOTE CONTROL LED on Al will light. When
operating at the transmitter, the LOCAL switch on A2 must 2. Turn 28V POWER SUPPLY circuit breaker CBI OFF.
be pressed.
3. Turn AC LINE circuit breaker A6CB6 OFF.
3-5. 2nd POWER LEVEL (low pwr) ADJUSTMENT
4. Open the Primary Disconnect switch.

NOTE

Perform this step only if using a second power


level.

Change 5 3-15
OPERATION 816R-2C

TABLE 3-5. Nominal Operating Parameters vs. Power Levels


(99.7 MHz)

Operating Parameters RF Operating Power - kW


10 15 20 21.5

Plate Voltage (kV) 7.82 8.40 8.50 8.48


Plate Current (Amps) 1.60 2.21 2.92 3.19
Screen Voltage (V) 375 500 610 710
Screen Current (rnA) 190 298 400 510
Grid Bias Voltage (V) -608 -607 -585 -566
Grid Current (rnA) 106 107 100 118
Forward Power (%) 47.0 70.0 93.0 100.0
Reflected Power (0/0) <0.2 <0.2 <0.2 <0.2
Filament Voltage (VRMS) 6.0 6.0 6.0 6.0
PA Efficiency Factor F (%) 79.9 80.8 80.5 79.5

IPA

IPA Voltage (Volts) 44 44 44 44


IPA Current (Amps) 17 17 17 17
FWD Power (watts) 500 500 500 500
RFL Power (watts) <10 <10 <10 <10

AC LINE VOLTAGE

Phase A-B (VRMS) 210 207 206 205


Phase B-C (VRMS) 204 203 202 202
Phase C-A (VRMS) 208 206 205 206

3-16
816R-2C OPERATION

TABLE 3-6. Nominal Operating Parameters vs. Frequency

Operating Parameters Frequency (MHz)


88.1 92.1 96.1 99.7 104.1 107.9

Plate Voltage (kV) 8.48 8.41 8.40 8.48 8.40 8.41


Plate Current (Amps) 3.19 3.20 3.21 3.19 3.24 3.26
Screen Voltage (V) 710 740 730 710 700 700
Screen Current (rnA) 450 482 510 510 450 490
Grid Bias Voltage (V) -515 -556 -574 -566 -488 -535
Grid Current (rnA) 110 115 115 118 95 103
Forward Power (0/0) 100 100 100 100 100
100
Reflected Power (%) <0.2 <0.2 <0.2 <0.2 <0.2 <0.2
Filament Voltage (VRMS) 6.0 6.0 6.0 6.0 6.0 6.0

Power Output (KW) 21.5 21.5 21.5 21.5 21.5 21.5


PA Efficiency Factor !IF" (%) 79.5 79.8 79.7 79.5 79.0 78.5

IPA

IPA Voltage (V) 44 44 44 44 44


44.0
IPA Current (A) 17 17 17 17 17
22.0
FWD Power (W) 500 500 500 500 500 500
RFL Power (W) <10 <10 <10 <10 <10 <10

3-17
OPERATION 816R-2C

0.82

¥:
a:

---------.
0 0.80
r- ~
0
<{
LL
>-
0 0.78
zw
(3
u: DATA DATE
LL
w
0.76 - OCTOBER 1993
w
r-
<t:
.-J
CL I I
88 90 92 94 96 98 100 102 104 106 108
FREQUENCY (MHz) (AT 21.5KW)

POWER OUTPUT = Ip Ep "K"


WHERE lp = PLATE CURRENT IN AMPS
Ep = PA PLATE VOLTAGE IN VOLTS
"K" = EFFICIENCY FACTOR FROM CHART

~ 0.82
a:

---
0
r-
-
-------..........
0
«
LL
0.80 ~
~
>-
0
z
w
(3 0.78
u:
u..
w
w
~
0.76 DATA DATE
:5CL OCTOBER 1993

I I I
8 10 12 14 16 18 20 22 24 26 28
POWER OUTPUT - KW (99.7 MHz)

93G0292

Figure 3-7. Amplifier Efficiency vs. Frequency and Power

3-18
816R-2C OPERATION
0.5 ~

~ '" ~
~

~" ""
~

""'~ "i\.'""
~
~
1,0
~~
~
""",1\./__~ ~.A.
~ -4

~ ~
;

"'-'"'" '"
~
1.5
""~

'" "'" '"


~

2.0 "'- "I\.. ~ ~

'~
~

~
)?

"" '" ~ ~O ~
2.5
~ "~
~

3.0
~ " 'I'\. """,
Ko
'" "-
~
~

'" , '""'" , ," ""


••
'""
"['\.

0
R
F
4.0
"\.
'~
"- "
"~
" ~"I~
'" ~ ~
~
"\.
~
, ~
~

~
5,0

~~I"" "~ ""~


W "" ~

'"
i'\
A
R
0
~ ~ '"'"" '"
" " .. ~O ,~ ~
~
~

0
P 10

~
'" "'"'"K'" "" " ,-'~"""'" "','""""
"",-
, / l'\.
~
1\
~
~
~

~
~

""
I\. ~
W
~
" ' " '" 'K "'I\.
" ~ ~
15 ~
E ~~ ...
~
'" ' "
'" " " '"""'" " " '" '" '"'" " "~
R 20 ~ ","- ~ ~

~ '"
"
• 25 K :Y 'i'\.. "- ~

r(
0
K
I
L
30

40
~ "
"",
'"
''","'"'""""''""I'"" "" '"" '"'" ",'""""',"" ,'", '"" "'" '" "
"'r-..
'"
7
!~
", ~
~
~
"K
"['\.
i\.

"I\.."I\. ,
"~
,,~
"~
W Ki'\.. '~ ~ K'\
A 50
,,:,~ I,
r'. """ I, "
T i\. "
" ""l\.

" "
~
I\.. I\.. I"
T
S
100 0 ~ '" '""" '" '" ~~'" '"" ~ ~ ~6' ~
~
f'\
""

~
"~
~ i\.
"~ 1\
~ I\..

"'~ "" '", "'\ ~'


'\ ~

'"",",'"", """ '" '""""'"'I'"" " "" "" ",


150 ~~ ~
"- f'.
'\
, " '"
~~. ~
, ~
""
~
'\.. ~ K ~
"-
,,~ "I\. ~
~'"" " '" '" ~
~ '" ""
7

"
"7_
.~ ~
200

""iK" "'- 1"'- '" '" ,


'" '
"V_"
" " '" ",
"
" ", '" " " " ~
""'" " '"I'"'""," "," """"'""'"'" '" '", "
300 K"\ ","
""'"", " "
",-"i\. '" '" K~
"" "
17'\., !\. ~
!\. ~ ~
~
~
~

~ ~/~ , ~
!\. ~ ~ ~

'"'" '" '" "'-'" " '\


'" "
I'(
", "
"- '\
"i\. I\. ~
1'\~
"\

'" '"
"" 'f'\ ~
500 I\..

'" '"
~ ~ ~

REVERSE POWER - KILOWATTS


r-..""-
<0 co 0
,.-

93G0373
o
C\J

Figure 3-8. Power to VSWR Conversion Graph

3-19
OPERATION 816R-2C

(This Page Intentionally Left Blank)

3-20
816R-2C THEORY OF OPERATION

SECTION 4 - THEORY OF OPERATION

4-1. GENERAL following paragraphs. Refer to Figure 4-3 and Schematic


195125.
The FM Transmitter, 816R-2C, operates in the 88 to l08
MHz range at a maximum rated RF output of21.5 kW. A 4-3.2.1 Metering Card, A3A 1.
CEC 802B solid state, wideband, FM exciter provides
excitation. The transmitter is equipped with circuits that The IPA Metering Card permits measurement and
maintain constant power output and protect the transmitter calibration of IPA supply voltage, current, forward RF
from overload conditions. A control panel provides power, and reflected RF power. The metering circuitry card
complete transmitter metering and tuning controls. Refer to is powered from the 50 Vdc IPA supply through VRI
the overall schematic diagrams for detailed circuit providing 12 Vdc. Switch SI-A, -B, -C and -D selects
information. which signal the external meter is monitoring. Resistors
R31 and R32 adjust the voltage sample. Op-amp U2-B and
resistor R27 control the current sample. Op-amp U1-B and
4-2. FUNCTIONAL DESCRIPTION resistor R23 control the forward power sample. Op-amp
U2-A and resistor R14 control the reflected power sample.
Refer to Figure 4-1, an input signal (monaural, stereo Comparator U1-A and R22 set the VSWR trip level.
composite, or SCA is supplied to the exciter. The exciter's Transistors Ql drives the VSWR LED while Q2 provides
RF output drives a two stage power amplifier. The first an excess-VSWR status output. Refer to Block Diagram
stage, the intermediate power amplifier (IPA), raises the Figure 4-3 and Schematic 195080 Figure 7-8.
output to a level of 500 Watts. The last stage, the RF power
amplifier, raises the output to the transmitter's rated power 4-3.2.2 Status Card, A3A2
output. The power amplifier is followed by a low pass filter
and a directional coupler which is connected to the station's The Status Card is a passive circuit consisting ot two LEDs
antenna system. A dc sample of the forward power from the driven by signals from the Metering Card A3A 1. The
directional coupler (DC l) is monitored by the auto power LEDs indicate power ON and high VSWR. Refer to Block
control circuit. If a change in output power is detected, a Diagram Figure 4-3 and Schematic 189626 Figure 7-9.
signal is sent to the power control board that increases or
decreases the plate and screen power supply input voltage to 4-3.2.3 Amplifier Assembly, A3A3. The Amplifier
compensate. A sample of the reflected power is also Assembly consist of an RF splitter, two RF amplifiers, an
monitored by the power control circuits. If an excessive RF combiner, and a 50 Vdc power supply. The splitter
amount of reflected power is detected, the control circuits consists of two quarter wave lengths 75 ohm line and a 100
I remove the transmitter plate voltage. The 24 Vdc power ohm balancing resistor. The input to the splitter, from the
supply provides power for the control circuits. exciter, is equally divided and impedance transformed to the
input of each of the two RF amplifiers. Each amplifier has
a power gain of approximately 16 dB and the outputs of
4-3. RF CIRCUITS both amplifiers are summed together by the con1biner to
provide an output of 500-600 watts. The combiner is the
Refer to Figure 4-2 for a simplified diagram of the RF drive reverse of the splitter and consists of the same parts, only
path. The drive path consists of the exciter A4, intermediate with greater power handling capability. The IPA is
power amplifier (IPA) A3ARl with its directional coupler followed by directional coupler A3DC 1. The coupler
A3DCI, coupling capacitor AI2CI, and power amplifier drives the IPA RF power meter and a VSWR warning
(PA) VI with its grid tuning components A12C3, A12Ll- indicator. The IPA receives its dc power from a 50 Vdc
L3, and A12C2. IPA metering and 3-phase power supply supply, part of which is on the AS assembly. The Amplifier
control circuits are also shown in Figures 4-2 and 4-4. Modules, A3AI and A3A2, consist of two circuit card
assemblies mounted on a common heat sink, refer to
4-3.1 Exciter, A4.
Schematic 189397. The two circuit card assemblies are RF
Amplifier and Control Assembly.
Refer to the 802B instruction manual, principles of
operation.

4-3.2 IPA, A3.

The IPA consists of a Metering Assembly, Status


Assembly, and Amplifier Assembly as described in the

Change 5 4-1
THEORY OF OPERATION 816R-2C

4-3.2.3.1 RF Amplifier. The RF Amplifiers use a system transistor flows through the over-current shunt, R209, and
of lumped coaxial lines to match the drain-to-drain the ON/OFF switch, Q203. Switching transistor Q203 is
impedance of 12.5 Ohms, balanced, to 50 Ohms, balanced. either ON or OFF in this circuit. The voltage on either side
See Schematic 189214. Transmission lines TL 101 and of the over-current shunt, R209, is reduced to +8 Vdc by the
TL 102, which have a characteristic impedance of 25 Ohms, bridge circuit. As the current flow, the over-current shunt
are seriesed at their output connection to TL 103 (for 50 causes a voltage drop, 0.5 Vdc when the current is 10
Ohms) and are paralleled at their input connection to the amperes. The voltage differential is amplified by a buffer
amplifier transistor, Ql, to present a 12.5 Ohm impedance. amplifier so that the output of buffer, U201 A is 6.4 Vdc,
The balanced 50 Ohm output impedance at the junction of when the current through the amplifier is 10 amperes. This
TL 1Oland 102 must be converted to a unbalanced output voltage appears on Jl-2 and is used to monitor the current in
signal for coaxial transmission. This is accomplished by each module. This current-related voltage is also buffered
TL 103. The length of this line is just long enough to and divided and feeds the non-inverting input ofU201B. A
present a large impedance to the unbalance current in its preset reference voltage of +4 Vdc is applied to the
shield. This type of current balun results is excellent inverting input ofU20 lB. When the current through the
balance to the transistor drains. amplifier exceeds 12.5 amperes, the output ofU201 goes
high and fires the SCR, Q202. This, in turn, pulls the base
The amplifier module is untuned. The operation of the of the switch driver, Q201 low. This turns Q201 ON which
transformers and the balun serve to limit the operating range causes the gate voltage of Q203 to rise to input voltage
to 80-120 MHz. The input of the amplifier is similarly value. Unless the gate ofQ201 is low, the switch turns OFF
broadband. Capacitor C 101 is adjusted to insure that and removes voltage from the amplifier. Each RF Module is
variations in such things as the gate capacity of the also protected with a 12 ampere fast-acting fuse.
amplifier FET transistor and the leakage reactance of the
input transformer are balanced out to provide a good input Over-temperature operation is detected by the thermal
match to drive the Splitter over the operating range. switch, S1, on the amplifier assembly. This switch is
mounted in contact with heat sink close to the attachment
The output transistors of the PA Modules operate in point of the amplifier transistor. Closure of the switch due
saturated push-pull, Class BC, with an operating angle of to over-temperature (80 degrees C.) causes current to flow
approximately 150 degrees and a drive level, at full output, in the opto-isolator U202. This causes the voltage across the
of up to 20 Watts. This results in a conversion efficiency in opto-isolator output transistor to fall to zero. Again, the
excess of 750/0. The bias adjustment for the RF transistor, switch, Q203 opens and removes voltage from the
R220, is adjusted to give an operating bias of + 1.5 to 3.5 amplifier. Operation of the thermal switch is through
Vdc. This bias adjustment also serves as a gain control. resistor R223.
During final testing, slight adjustment of the bias control is
made to insure that the gain of both RF amplifiers are equal. 4-3.3 RF Power Amplifier, A12.

There is an optimum drive level for the PA Modules. As The RF power amplifier is driven by the IPA through a
the amplifiers are under-driven, they go into a linear mode matching network consisting of the COUPLING control
and conversion efficiency drops. Over driving the (C1), the PA GRID TUNE control (C2), and L1, 2, 3 (See
amplifiers results in excessive harmonic content at the Figure 4-2). Capacitor C3 and resistor R1 swamps the
amplifier drains which also causes a drop in conversion power amplifier grid circuit and provide a more uniform
impedance to the IPA under varying drive conditions.
efficiency. Drive level is adjusted by varying the exciter
Inductor L 14 and the distributed capacity of resistor R75
output to obtain the desired drive power to the final
couple R75 to the cavity, forming a suppressor that
amplifier tube.
dampens the higher order cavity resonances that can occur
near the third harmonic of the output frequency. Cathode
4-3.2.3.2 Control Assembly. The Amplifier Module tuning (or peaking) capacitor C39 improves the bypass
Control Assembly is an on-board protection system to action at the operating frequency. Inductor L5 is the power
protect the module from over-current and over-temperature. amplifier grid bias feed choke.
The Schematic Diagram, 189211, shows that the operating
volt..ge for the protection circuitry, + 15 Vdc, can be derived The power amplifier is a plate tuned 4CX15,000.A. tube that
from either the +24 Vdc Control Power Supply of the is operated as Class C. The tube screen is grounded and the
transmitter or from the +50 Vdc supply through the
isolation diodes, CR201 and CR202. Voltage for the RF

4-2 Change 3
816R-2C THEORY OF OPERATION

cathode is placed 750 Volts (nominal) below ground to 4-4. POWER SUPPLIES AND POWER CONTROL
provide screen voltage, as shown in Figure 4-5. A fixed bias CIRCUITS
from the power amplifier bias power supply is applied to the
control grid through terminal A5E12, resistor A5R13, and 4-4.1 General.
terminal A5E 13. When an input signal is present, grid
current flows and develops grid leak bias across resistors Refer to transmitter schematic 189632 for the following
R35 and R36. The increased negative potential on the grid discussion. There are five separate power supplies in the
causes the diode in the power amplifier bias supply to transmitter. Three of the five, the plate, screen and power
reverse bias, preventing grid current flow through the amplifier bias power supplies provide voltages to the power
supply. Hall effect probe A5Z1 monitors the amount of grid amplifier. The Driver supply, furnishes voltage to the IPA
current for control panel metering. stage. The 24 Vdc power supply provides power to the I
control circuits.
The power amplifier plate circuit is coarse-tuned from 88 to
108 MHz by resonating adjustable coaxial resonators, 4-4.2 24 Vdc Power Supply, PIO A10. I
Figure 4-6. The resonators are in the area between the tube
shelf and the sliding shorting plane. Two motor-driven The 24 Vdc supply is a fully self-contained power supply. I
capacitors permit more precise tuning (capacitor C51) and A parts list and schematic diagram is included in this
loading (capacitor C50). RAISE or LOWER switches S10 manual.
or SII (PA TUNING) and S12 or S13 (PA LOADING) on
control panel A 1AI, control the capacitor drive motors. The 4-4.3 Power Amplifier Bias Power Supply, PIO Al O.
dc blocking capacitor C2 is located between the top of
power amplifier tube and input to the air chimney. Figure The power amplifier bias power supply provides the power
4-7 shows the electrical equivalence of the plate tuning amplifier with fixed grid bias that holds the tube near cutoff
circuit. when no signal is present on the grid. Single-phase primary
power is applied through contactor A8K1 and step-up
4-3.4 Low-Pass Filter, A7. transformer T1 to a bridge rectifier network. An L-section
filter is formed by inductor L 1 and capacitor C2.
Low Pass filter A7 (Figures 6-1, sheet 2) consists of two
coaxial filters in tandem. The first filter has a cutoff The power supply output is applied to the grid of the power
frequency of 130 MHz, while the second has a cutoff amplifier through diode CR5. Diode CR5 blocks grid
frequency of300 MHz. current flow through the supply when the grid leak bias
exceeds the fixed bias. A sample of the bias voltage is
4-3.5 Directional Coupler, DC I. applied through resistor R3 to front panel meter A1M1 for
monitoring.
The directional coupler provides a proportional dc voltage
to both the forward and reflected circuits of A2A6. The
output of each is then routed to, and can be displayed on,
the Forwardl Reflected Meter (AIM4).

Change 5 4-2.1
THEORY OF OPERATION 816R-2C

(This Page Intentionally Left Blank)

4-2.2 Change 3
816R-2C THEORY OF OPERATION

MONAURAL,
STEREO
{I
FM EXCITER
:, 1-------..[----.....1
IPA __ DIRECTIONAL
COUPLER I'---:-+I
RF POWER
AMPLIFIER
LOW PASS
FILTER
I.--+
COMPOSITE, 4 802B
SCA I '-----t-- ----' , A12
I A7

I
:A3

I IPA
SUPPLY
I
A5

FORWARD REFLECTED

.-
I FILAMENT
+--..1 SUPPLY
POWER
SAMPLE
POWER
SAMPLE
1

J ~
PABIAS
SUPPLY I ----L

1-4
lBr
A
3 POWER PLATE
SUPPLY
PHASE / CONTROL
LI NE -------+---+1 UNIT
VOLTAGE C A9*~~..1 SCREEN
- \ SUPPLY VSWR
CALIBRATE
t CONTROL VOLTAGE
AND
AUTO POWER
24V DC
CONTROL
CONTROL
CIRCUITS
SUPPLY
A2A6
A10PS1

* INPUT TO PLATE AND SCREEN 95G0196d

POWER SUPPLIES IS 3-PHASE


CONTROLLED VOLTAGE.

Figure 4-1. FM Transmitter 816R-2C, Block Diagram.

Change 5 4-3
THEORY OF OPERATION 816R-2C

V1
A3AR1
A3DC1 A12C1
COUPLING
EXCITER IPA
A4 FWD REFL
A12C3 A12C2

PA
GRID
TUNE

IPA
METERING
A12R1

I A12A3
C4-12

I
/
A3

A3R4

A3R1

A3R3
TO
3 PH : 0---. DRIVER
POWER SUPPLY
SUPPLY
: 0---. CIRCUIT
. 0---. BREAKER
AS

TO
PLATE-ON
CIRCUITRY

93G0294

Figure 4-2. RF Drive Path"

4-4
816R-2C THEORY OF OPERATION

A3

AMPLIFIER ASSEMBLY

A1

• DC1
RF OUTPUT
RF INPUT DIRECTIONAL TO
FROM SPLITIER
COUPLER FINAL
EXCITER AMPLIFIER

A2 o >
3: w
u. a:

A1 A2

IPA IPA
METERING STATUS
ASSEMBLY ASSEMBLY

98G0092

Figure 4-35 IPA Block Diagram, A3.

Change 3 4-5
THEORY OF OPERATION 816R-2C

AC VOLTAGE
APPLIED TO
rv FULL
POWER

PLATE AND
SCREEN
TRANSFORMERS
0v REDUCED
POWER

.../ ~
GREATLY
-~ REDUCED
POWER

SCR's

240 VAC ONE OF THREE


INPUT ONE PLATE
OF THREE TRANSFORMER
PHASES SECTIONS

ONE OF THREE
SCREEN
GATING
TRANSFORMER
CARD SECTIONS

CTRL SIG. 0-5 VDC

POWER
CONTROL PLATE
. . . . - - - - - ON/OFF
CARD
CONTROL
PIO A2A6
DIRECTIONAL
COUPLER

MOTOR
A10A2K~
MAN.
DRIVEN
MANUAL
'-------0--- POWER
AUTO.
CONTROL
CONTROL
CARD
93G0296
PIO A2A6

Figure 4-4. SCR Power Control, Simplified Diagram.

4-6
816R-2C THEORY OF OPERATION

A12L6

PLATE
SCREEN CURRENT
OVLD
A5K2

A12 LS
4.7 uH
n
A12T1

A12R55
A5K3
22fl
+ PLATE
OVERLOAD
SCREEN
SUPPLY
A5
A10A1
CR5 PA
BIAS A12 R35
2.5Kfl

PA BIAS
SUPPLY
A10 HALL
+ EFFECT GRID
DEVICE CURRENT
A5Z1

A12R36
3Kfl A5R13
10 n.

93G0297

Figure 4-5. Power Amplifier DC Bias Circuitry Simplified Schematic.

Change 4 4-7
THEORY OF OPERATION 816R-2C
C52
S15
C 2
C49

C48
C84
C85
TUBE S7
CHIMNEY

P4,J4
P5,J5

SLIDER
DECK

PA
TUNING
BLOCKING
(C51)
CAPACITOR
C2 (REF)

R75 - PA LOADING
(C50)

TUBE
TUBE " I /
SHELF -·D-

A3

C83
C2
93G0340A

S6
Figure 4-6. PA Cavity, A12.

4-8 Change 3
816R-2C THEORY OF OPERATION

C2 C50
A12L6 or LOW
B+ ....- t---' '--_.--- - - _ A _ - - - l ~---------__t_--- ------___I ~------+. PASS
E FILTER

LR

£~
C51

oV
LOADING
(Lt2
.::L
-=- :
:
MONITOR
J2 SAMPLE
V1

e
TUNING
B2
-
B3 _

.::L.:::r:: i2:<
(ltL13{)_
L.<J6
MONITOR
SAMPLE

: PLATE TANK CIRCUIT


: PIO A12

NOTE:
C2 IS THE CAPACITANCE BETWEEN TUBE ANODE AND THE CAVITY CENTER CONDUCTOR
A12C50 IS THE CAPACITANCE BETWEEN MOVABLE PLATE 1 AND THE TUBE ANODE
A12C51 IS THE CAPACITANCE BETWEEN MOVABLE PLATE 2 AND THE TUBE ANODE
LR IS THE LUMPED CONSTANT EQUIVALENT OF THE SHORTENED 1/4 WAVE RESONATOR

93G0299A

Figure 4-7.. PA Tuning Circuit, Simplified.

4-9
THEORY OF OPERATION 816R-2C

4-4.4 PA Plate Power Supply. and Q5 amplify the control signal and apply the signal to
the gating cards. Capacitor C5 and resistor R36 phase
The power amplifier plate power supply provides plate compensate the power control servo loop.
voltage to the power amplifier. Primary components of the
supply are transformer T1, 3-phase bridge rectifier assembly 4-4.7 PA Screen Power Supply.
Z 1, filter choke L 1, and filter capacitor C 1. A meter
multiplier board, A 12A 1, samples plate voltage and allows The 3-phase regulated voltage from the power control unit
constant monitoring. Input power to transformer T 1 is is applied through transformer T2 to a silicon 3-phase
controlled by SCR (silicon-controlled rectifier) power full-wave bridge rectifier assembly A5CR 1in the power
control unit A9. This unit, connected as a closed loop amplifier screen power supply. The output of A5CRI is
regulator, maintains constant power output to offset filtered and applied to the cathode circuit of the power
conditions of varying line voltage. amplifier at the secondary center tap of filament transformer
AI2Tl.
4-4.5 Power Control Unit, A9.
4-4.8 Driver Power Supply, PIO A5.
Power control unit A9 regulates the 3-phase ac power input
to the power amplifier plate and the power amplifier screen The driver power supply is a 3-phase, full-wave, type using
transformer. SCR assembly Z 1 has three SCR pairs; one a single section choke input filter. It nominally delivers 45
pair in series with each primary \vinding of the 3-phase Vdc at 25 amperes to its load. The supply's primary power
power transformers. Each pair is connected within the delta is switched through relay A5KI which is operated by the
circuit of the transformer primaries. Three control cards are PLATE ON circuitry. The supply is protected through
located within the A2 card cage. Each control card controls circuit breaker A6CB3.
the firing (tum-on) point of one SCR pair (Refer to Figures
4-4 and 4-8). 4-4.9 Filament Voltage Regulator, A2A4.

A common dc control signal from power control regulator When the Filament Regulator Card is in the automatic
A2A6 is fed simultaneously to each control card. This mode, the filament voltage regulator detects and
control signal governs the firing of the SCR pairs that compensates for sustained fluctuations in the input ac
regulate the input power applied to the power supplies. voltage (Refer to Schematic Diagram Figure 7-2). The
Upon receipt of a PLATE OFF control signal, a ground is fluctuations are detected by a true rms detection circuit
placed across the inputs of each card. which in conjunction with associated circuitry, including
motor control circuits, adjusts the setting of variable
4-4.6 Power Control Regulator, PIO A2A6. transformer A8A2Tl. The output voltage of the variable
transformer is then applied to the primary of power
The power control regulator located on A2A6 provides the amplifier filament transformer A 12T 1. The variable
necessary control signals to operate power SCR control unit transformer voltage is also applied to the primary of
A9. Assembly A2A6 supplies a soft-start power amplifier detector circuit transformer A2T4.
plate supply tum-on signal, a negative voltage for manual
power control, and amplifier mixer functions for automatic Voltage for the power supply circuits on the filament
power control. regulator board is derived from sampling transformer A2T4.
This ac voltage is rectified and applied to voltage dropping

I When the PLATE ON switch is pressed, 24 Vdc is supplied


to A2A6J 1-30. The 24 Vdc activates transistor Q 1 to tum
on relay A8K6. Relay A8K6 in tum supplies 3-phase ac
resistor R33. Capacitor C24 provides filtering. A
three-terminal 15 Vdc regulator U9 supplies voltage to the
15 Vdc circuits with additional stabilization povided by
control power to A2TI-3. An RC time delay circuit formed capacitors C27 and C28. Voltage dropping resistor R34
by resistor R41 and capacitor C 12 maintains A8K6 closed feeds three-terminal 5 Vdc regulator UI0 while capacitors
for a short interval after the PLATE OFF switch is pressed. C29 and C30 provide additional voltage stabilization. LED
ITransistors Q2, Q3, and Q4, also energized by the 24 Vdc, DS5 indicates voltage present on the 5 Vdc line which
provide the dc tum-on signal to the gate cards. Resistors implies that the 15 Vdc circuits are also powered.
R34 and R35, and capacitor CII modify this signal to
soft-start the high voltage power amplifier plate power
supply. Zener regulator VR4 provides -10 Vdc to
MANUAL power adjust resistor A2A9RI. Transistors Q4

4-10 Change 5
816R-2C THEORY OF OPERATION

FORWARD
POWER
DIRECTIONAL
1----------1
COUPLER I +10Y I
DC1
1 1
1 os 1
-

I
I
if
10 - -

+ U4
-

6
- -

R48
- - i
J1
38 ) -
I - - - - .
I
K2
o-RESET I
I
I
I _
~- R24
2N2222A ~1
R22
4.7K
I
I 04 2N2222A I

I I I
I

12f- +24 47 22)


I I I. I I C6 I

1
~-----'\.24 >-~--< 13~.
---"7
. L- : ~14)-<261
I" 1 C7-=
T 0.1 I

I I I: 1 I T O.1 -10Y I
L P/O A2A_6 1 I · SET I -= q I
I ~

POWER CONTROL
--<1if- +24 I
PIO A2A6
L.:
D- ~----J

~t
A1A1S1 PS
I
AUTO 1~32> I --l , _
MANUAL J
he NO
LOA10A2_y

l ~3S>------'
A1A1S2

POWER ADJUST
A1A1S7 P6
I
J
0-73S>--------4-----------/·'1
RAISE I
~34>
I
)---- II
A14T1, T2
PRIMARIES
(2 PLACES)
"I
8
8
LO WE R 10-736 >_! - t - - - - f - - - i - - - . , . - - -_ _- - '
8 2A3
14~
A9Z1-A A
C
A1A1S8
I

1
-
N
120VAC FROM ------------~ P
~--
A6XF14-2

6 - - (16~----- 6
P4

Sl 80
08
14 U
T

8
+24

y .. lB..
f----+---------::'f'---J
P
K~ ~ 9 ••• 1~1 :
A9Z1-B
0
W
POWER
RAISE
8 (1 ~ I E
R
I P4
-------+---~ 3 " / I

(1:~ ~ ~ C 11
I
J
~y
.9•. :

POWER 4 13 I 93G0300

LOWER 1~ I
---~O)-

I
TO K2
I
i7)-T--
I PS-3S(A1A1J1-3S)
LP/O ~OA2 I

Figure 4-8. Power Control Circuits, Simplified Diagram..

Change 5 4-11
THEORY OF OPERATION 816R-2C

4-4.9 Filament Voltage Regulator, A2A4. - Continued If the voltage from the RMS-to-dc converter circuit is
within the 4.95 to 5.05 Vdc windo\v, the outputs of the
Negative supply voltage is provided via diodes CRI and comparators will both be high and the output of AND gate
CR2 via resistor R3 and capacitor C24 to card edge U4C will go high illuminating green LED DS4 indicating
connection 38 for distribution to other circuit cards in the proper filament voltage is present. If the voltage from the
transmitter. RMS-to-dc converter is not within the 4.95 - 5.05 Vdc
window, the circuit \vill then operate to make the necessary
A sample of the voltage feeding the power amplifier tube corrections if switch S2 is in the AUTO position.
filament transformer is applied via transfonner A2T4. This
ac signal is applied to RF filtering components inductor L 1 Assuming that switch S2 is in the AUTO position, if the
and capacitor C 14. Inductor L 1 has a 4.7 j.lh parallel filament voltage rises above + 1% of the nominal value
resonance which falls in the FM broadcast band providing a setting, the following actions are taken. The output of the
high impedance path for frequency modulated RF signals. 5.05 Vdc comparator will go low at U8-2 causing the output
Capacitor C 14 is a 100 pf capacitor whose ofU4 to go low and DS4, the LOCK LED, will extinguish.
series resonance falls in the FM broadcast band providing a Device U8-Il will go high bringing the input ofUI-13
low impedance shunt path for frequency modulated RF high. When either of the comparators goes low, indicating a
signals. These filtering components are used in several correction is necessary, U2B, U2D, and U2C in
locations in the filament regulator card, and provide the combination act as an OR gate forcing U 1-10 high which in
same filtering functions as described here. turn triggers timer, U6. When U6 is timing, the output pin 3
goes high illuminating yellow LED DS 1. At the same time,
The filament voltage sample signal is then applied to the UI-3 output goes low which takes the input ofU4-1 low.
RMS-to-dc converter circuit via voltage divider resistors RI This output is fed through switch S IA to inputs UI-9, Ul-
and R2, and through capacitor C 15. This RMS-to-dc 12 and U2-1 bringing them all low. Hence, while the timer
converter circuit is based around U7, a true nns-to-dc is in its timing state, the outputs ofUIC, UID, and U2A are
converter integrated circuit. The converter directly all high, inhibiting the actuation of relays Kl, K2, and K3
computes the true RMS of any complex input waveform respectively. Once the timer U6 has timed out, the inputs of
containing ac components. It has crest factor compensation UIC, UID, and U2A fed from s\vitch SIA are brought
which allows very accurate measurements up to 300 kHz. high. At this point if the filament voltage is still above the
The crest factor of a wavefonn is the ratio of the peak signal + 1% nominal value, both inputs of U 1 will be high,
swing to the RMS value. Components C17, R 17, R 18, C 18, enabling actuation of relay Kl and the clutch assembly on
RI9, and C20 provide time constant and filtering functions the filament voltage adjust variac motor. Simultaneously,
for the converter. both inputs ofUID will go high forcing its output pin 11 to
go low. The LOWER LED (DS2) will be illuminated and
Test point 3 (TP3) provides easy access to the dc voltage relay K2 will be activated which in turn actuates the lower
representation of the filament RMS voltage. During nonnal winding in the motor driving the filament voltage control
operation of the filament voltage regulator, resistor R2 is variac. Once the variac brings the filament voltage back
adjusted so the output of the RMS-to-dc converter circuit is inside the range of nominal operation, the comparator
5.00 Vdc when the filament voltage has been preset to the output ofU8-2 will go high, and the above logic actions are
nominal value by the operator. The output voltage is then reversed removing power from the filament voltage
fed to window comparator composed ofU8 and related regulator variac motor.
devices. The voltage references for the window comparator
are provided by UII, a very high precision IO-Volt The raise function operates just as the lower function
regulator, and voltage divider components R20, R21, R22, described above, but instead activates the raise circuits. It
and R23. In normal operation, resistor R20 is adjusted to may be noted that if future adjustments by the operator are
provide 5.00 Vdc at TP2. The corrected reference voltages required in the automatic mode, resistor R2 may be used as
are then applied to their respective comparators. Pin 5 of U8 a simple filament voltage adjustment control.
has 5.05 Vdc applied, and pin 10 ofU8 has 4.95 Volts
applied. These voltages will be correct if resistor R20 has The timing period of timer U6 is provided to guard against
been properly adjusted for 5.00 Vdc on TP2. The 50 mV constantly correcting momentary excursions in the filament
voltage drops are provided by voltage divider resistors R21 voltage. This delay timing period is adjustable from 0 to 12
and R22. This 100 mV total window provides a total ± 10/0 seconds with resistor R7.
window for the voltage comparator, and hence for the
voltage regulator circuitry.

4-12
816R-2C THEORY OF OPERATION

4-4.9 Filament Voltage Regulator, A2A4. - Continued Figure 4-10. Circuit breaker A6CB5 is connected inside the
delta of plate transformer T 1. It also serves to interrupt
If automatic operation of the filament voltage regulator primary power to the PA screen transformer T2 through
circuit is not desired, switch S1 can be put in the MAN associated circuit breaker A6CB4. Circuit breaker A6CB3
(manual) position. This effectively takes the regulator out of controls power to driver power supply (IPA) transformer
the circuit, but the green LED lock indicator will still show T5. AC line voltage metering is provided by ac meter
if the filament voltage is within nominal range. A2M 1. In addition to the three phase-to-phase voltages,
A2M1 can monitor the power amplifier filament voltage.
While in the manual mode, momentary switches S2 and S3 BLOWERS circuit breaker A6CB2 controls application of
can be used to manually activate the clutch and raise or primary power to cavity blower Bland FAN fuses A6F7,
lower circuits respectively. Other than the timer not being F9, and FI2 through filament-on relay A8K2. Relay A8K2
active in this mode, these switches simulate the output of is energized when the filament switch (S2) is turned on.
the comparators per the operator's command, thus manually Application of primary power to the filament circuits, the
raising or lowering the filament voltage. This provides a exciter, the power amplifier bias power supply, and the
convenient way to determine ifmost of the digital logic and power amplifier tuning and loading motors is relay
the solid state relay are functioning properly should a controlled. Filament-on relay A8KI and blower-on relay
problem occur. Devices U3A and U3B are provided to A8K2 control application of power to the regulated filament
insure that the raise and lower functions are not activated circuit through auto-transformer A8A2TI. Relay A8K1 also
simultaneously by circuit failure or accidentally by the controls application of power to 802B exciter A4, to power
operator using the manual controL amplifier bias power supply, PIO A10, and to the power
amplifier tuning and loading motors B2 and B3
While in the manual mode, the operator may depress both respectively. Power to the exciter and the motors is through
the raise and lower switches simultaneously and the only isolation transformer T4. Time totalizing meter A2M2 is
action to take place is the timing of U6 as noticed by the placed across the load side of filament-on relay A8Kl.
illumination of yellow LED DS 1. This allows the operator a
convenient way to set the time delay ofU6 without The filament, exciter, and power amplifier bias supply input
affecting the other circuits. power circuits are protected by associated fuses. These
circuits receive power from the blowers circuit breaker,
Solid state relays K 1, K2 and K3 provide a return for the ac A6CB2.
voltages already on the windings of the clutch, and the
lower and raise circuits of the variac drive motor. Relays K2 4-5.2 Transmitter Tum-On.
and K3 also have the return path for the ac voltages routed
through micro-switches S1 and S2 on the variac assembly. The transmitter is energized by pressing FILAMENT ON
This provides a secondary measure against operating the switch AIAIS4 on the Al control panel. Relay A8K2 is
filament voltage regulator outside of the prescribed range energized and is applied to the blower motors. After
provided by the mechanical stops on the variac drive motor. sufficient air pressure is created in the power amplifier
cabinet, air switch A I2S 1 is closed and relay A8K 1 is
4-4.10 Filament Voltage Distribution. energized.

The filament voltage distribution is shown in Figure 4-9. After a 30-second delay, relay A8K4 is energized. The
Filament voltage regulator A2A4 maintains a constant rms PLATE ON switch is pressed energizing relay A8K3 which
voltage on the filaments as discussed in Paragraph 4-4.9. applies 24 Vdc to the base of transistor A2A6Q3. This turns
on the control amplifier, which applies input voltage to the
plate and power supplies.
4-5. PRIMARY POWER DISTRIBUTION CONTROL
AND OVERLOAD CIRCUITS The transmitter may also be energized by pressing the
PLATE ON switch which latches relay A8K3, and
4-5.1 Primary Power Distribution. energizes relay A8K2 through contacts 8 and 5. Pressing
this single switch (PLATE ON) enables the transmitter to
The 60 Hz, 3-phase primary power is distributed to the go through the above sequence of blower, filament, time
various circuits of the transmitter via circuit breakers and delay and plate on.
fuses mounted on circuit breaker panel A6. Refer to

Change 5 4-13
THEORY OF OPERATION 816R-2C

I
WHT
29 <
~ A2A4
115
I FILAMENT
VAC
0 13 < VOLTAGE
REGULATOR
RED··
I
25 <
Lv--v--V--V--V
46 2 42 1 6

via GRN
V
ORG BLU
V
lj V

A2T4

WHT BLK

FILAMENTS

~t.61 2fG~. .... 4 ~12 C55


2
1 3

~.~~_FI~E~ ~~~~~~1!-2~-2JII~1
v~
L~~' 13 A8A2 I' A12C56 A12T1
-~-T T1 2
A6F13
-~-~ A8K2B A8K1 P7 -1---

t 3 J1

~ I :
R20
9.09K

R19
9.09K

R17
5K

P/OA2A7
CARD CAGE CaMP. ASSY : 93G0301

Figure 4-9. Filament Voltage Distribution.

4-14
816R-2C THEORY OF OPERATION

F6 --.t:
B ~ ---,--: REGULATED DC

F8 --.t: OPERATING/CaNT
VOLTAGE FROM
C~_: REGULATOR A2A8

A~:
POWER

n
CONTROL
A2A8
200-250 VAC 24 VDC
60 Hz 3 PHASE
A8TB1
A6CB5 U ON RELAY
A8K6
~

ill
C- {- ( A6CB6
,----- ~
-----------------------1
-------------------------------1

: T1 PRJ WINDINGS

A6CB4 : T2 PRI WINDINGS

-----------------------------~ ~--'-------_->.
. - - t - - - - - - - - - - - - - - - - - - - -__---+-----~-.....---
a - - + - + - - - - - - - - - - - - - - - - - - -+--+----~:..- ~ .--~-----------'
DR IV ER - - - - - - - - - - - - - - -
~

.~
PWRSUPPLY
A6CB3
l.-- ~--o-L-
~ ~
24 . - - - - - - . --D
,---- ~ ~

~1
VDC
~OO
'------_w

IPA
A5K1

~ONITOR
I PHASE
AC LINE
VOLTMETER
A2A7 SWITCH Vm

A6CB2 FILAMENT

~----+-+--­ CAVITY
~---t-1.-+--- BLOWER
B1
B
VARIAC DRIVE
MOTOR
A D A8A2 B1
_
FILAMENT
VOLTAGE
A6F13

B C BL~~~RS REG
A6F1 ON RELAY A2A4

~()-- ---t..--+--------+-----------+---

II
C >--~~(}----~-------
A6F3 .

B >--~~v--
A6F2
__
---'--.,.J

A~-tr}-------.
A6F4

D
FIL ON
PA BIAS
POWER
SUPPLY
RELAY PIO A10
A8K1

Figure 4-10. AC Power Distribution.

Change 5 4-15
THEORY OF OPERATION 816R-2C

4-5.3 Exciter Power Control Override. 4-5.4.2 Theory of Operation.

An output override voltage is supplied to the 802B exciter The forward power signal from the directional coupler,
when the plate voltage is turned OFF. This mutes the output DC 1, is amplified and buffered by U4. Resistor R9 is an
of the exciter while the power amplifier plate voltage is offset null adjusted for zero output at TP 1 when no input
turned OFF (Figure 4-11). The voltage is applied from the signal is present. Resistor RIO is adjusted to provide a
124 Vdc power supply through contacts 3 and 9 of relay 1000/0 forward power indication on the panel power meter
A8K4 to the 802B exciter power supply regulator. (AIM4) at the customer's specified TPO.

4-5.4 FWDIREFL Calibrate and Auto Power Control Unit, The output ofU4 is also present on terminal board
A2A6. Al OTB2-13, through a 2.2K ohm isolation resistor, R53, to
provide remote metering of forward power.
4-5.4.1 Functions. The FWDIREFL CALIBRATE AND
AUTO POWER CONTROL portion of the A2A6 card The positive output ofU4 is coupled through diode CRl1
performs these functions (Refer to Schematic 180162): and compared at the inverting input ofU3 against the
negative voltage from either resistor R8 (Normal Power) or
1. The forward power signal from the directional coupler resistor R7 (Second Power) in the automatic mode. The
is buffered and amplified to provide a panel power output ofU3 is used to raise or lower the transmitter plate
meter reading of 1000/0 at the customer's specified voltage, as necessary, to maintain the selected power level.
transmitter power output (TPO). Full scale meter The input to U3 is switched from resistor R8 to resistor R7
indication is 120% in the FORWARD POWER by relay Kl which is activated by applying +24 Vdc to relay!
position. KI coil through terminal board AIOTB2-1. Normally,
resistor R8 sets the normal operating TPO reference while
2. The forward power signal from the directional coupler resistor R7 is adjusted for some lower value, perhaps
is compared against either of two internal, adjustable necessary during emergency operation with a generator
voltages for automatic power control. Two discrete unable to supply the full power load.
levels of power control are remotely selectable and
maintain the desired power to within 10/0. The reflected power signal from directional coupler DC 1 is
amplified and buffered by UI. Resistor Rl is an offset null
3. The reflected power signal from the directional coupler adjustment for zero output at TP2 when no input signal is
is buffered and amplified to provide a full scale reading present. Resistor R2 is adjusted to cause a 100/0 reflected
of 12% of the customer's specified TPO on the panel power indication on the panel power meter AIM4 when the
power meter in the REFLECTED POWER position. reflected power reaches 100/0 of the customer's specified
TPO. Resistor R3 is adjusted to simulate that 100/0 reflected
4. The reflected power signal from the directional coupler power level when the TEST switch S1 is depressed. This
is compared against an internal limit to smoothly fold allows testing of the VSWR protection and metering
the forward power level back when a slowly rising circuits. The output ofUl is fed through resistor R43 to the
VSWR level is detected. Forward power is reduced to gate of the VSWR overload SCR A2A5Q4 when the
keep the reflected power at 5 to 60/0 of the customer's VSWR protect is in the enable position. Resistor R4 is
specified TPO. adjusted to fire SCR A2A5Q4 when the reflected power
reaches 10% of the customer's specified TPO. When SCR
5. A reflected power signal from the directional coupler Q4 fires, VSWR overload relay AIIK9 activates, removing
can remove power from the transmitter and light the power from the transmitter and illuminating the VSWR
VSWR tally LED when a rapidly rising reflected power OVERLOAD LED.
level greater than 100/0 of the customer's specified TPO
is detected. The output of U 1 is also present on terminal board
AI0TB2-12 through 2.2K ohm resistor R46 to provide
remote metering of reflected power.

4-16 Change 5
816R-2C THEORY OF OPERATION

4-5.4.2 Theory of Operation. - Continued FAULT RESET s\vitch AIAlS16 on the main control panel
is pressed. Plate voltage is removed by overload relays
Devices U2 and U3 form the VSWR foldback circuit. A A5K2, A5K3, or A5K4. The 24 Vdc pulse that triggers the I
sample of the buffered reflected power signal from U 1 is SCR is simultaneously routed to the recycle circuit via
fed to U2 through resistor R5. Resistor R6 is the offset null diodes CR9, CRIl, or CRl2 to be used to automatically
adjustment for U2 and is adjusted to give zero output at U2- restart the transmitter.
6 when no input signal is present. The output of U2 is
coupled through diode CR6 to the automatic power The automatic recycle circuit provides a timed restart pulse
comparator, U3. Resistor R5 sets the level so that the output for up to four overload occurrences within a 30-second
voltage ofU2 will exceed that ofU4, causing the power to period. The card as shipped will allow only two restart
be reduced, when the reflected power exceeds 5-60/0 of the pulses in a 30-second period. However, it may be
normal TPO. The VSWR foldback circuit is defeated by the reconfigured to allow four restart pulses in a 30-second
circuitry of the ten second timer U5. The timer is triggered period by removing the jumper between terminals A and B
by sampling the anode voltage ofVSWR overload SCR on the card and replacing it between A and C.
A2A5Q4. The response time of the VSWR foldback circuit
is relatively slow. A sudden significant increase in VSWR, The auto recycle begins when the 24 Vde pulse is applied tal
as in an arc, would cause the VSWR overload SCR to fire. the base of transistor Q2 causing it to conduct. The output
Power to the transmitter is removed, the VSWR ofQ2 is fed to timers UI and U4. Timer Ul provides a
OVERLOAD LED is illuminated and the VSWR foldback 0.5-second delay, then triggers timer U3 which generates a
circuit is disabled for ten seconds. The VSWR foldback 0.5-second output pulse. This pulse is fed through gate U2A
circuit is disabled to allow the VSWR overload circuit to to inverter Q3 which causes Q6 to conduct and charge
sample the VSWR at full power thereby preventing capacitor C22. The charging current of capacitor C22
operation into a dangerously deficient load. momentarily energizes relay Kl which closes the PLATE
ON circuit through switch S2. The charging current of
4-5.5 Overload Protection. capacitor C22 also flows through RECYCLE PULSE
indicator LED CR6 giving an indication of the recycle
Relays A5K2, A5K3, and A5K4 are adjusted to energize circuit operation.
and remove power from the transmitter when an overload
occurs in the plate or screen supply or when the VSWR Gate U2D conducts the output pulse from timer U 1 to
exceeds a preset level. Screen current through resistor A5R8 counter U5. Counter U5 counts the number of recycle
produces a voltage that is applied to relay A5K2 through pulses and provides a logic 1 output at terminal C \vhen four
resistor A5R 15. The plate current through resistor A5R7 pulses have been received. Depending on which terminal
produces a voltage that is applied to relay A5K3 through has been strapped to terminal A, two or four recycle
resistor A5R16. When SCR A2A2Q5 is gated on, a ground attempts in a 30-second period will close gates U2A, U2B,
is applied and relay A5K4 is energized. Each relay is U2C, and U2D and prevent any further attempts by the card
adjusted to trip at a factory preset current level. The relay to restart the transmitter. RECYCLE LOCKOUT indicator
contacts are in series with plate control relay A8K3. If an LED CR2 will light to indicate this condition. When the
overload occurs, the corresponding relay trips and 30-second period of time has elapsed, a pulse is generated,
de-energizes relay A8K3, removing plate power from the inverted by tramsistor Q 1, and applied to U 5 to reset it to
transmitter. zero. This clears the memory and allows another sequence
to begin. If the maximum count of two or four pulses has
4-5.6 Overload and Recycle Board, A2A5. not been received in the 30-second period, the timer will
also reset the counter automatically.
Overload and recycle board A2A5 contains circuits that
provide overload indication and memory, automatic power AUTO-RECYCLE switch S2 may be used to disable the
on recycling, and filament control circuit interlock status auto recycle card when desired. This is usually done during
(Refer to Schematic 180167). tune-up or maintenance procedures. RECYCLE TEST
switch S1 may be used to test the automatic recycle circuit
When an overload occurs in the PA plate, PA screen, or during maintenance procedures by simulating an overload
Ivs WR circuits, a 24 Vdc pulse is supplied to the pulse at the input to the recycle circuit.
appropriate SCR Q4, Q7, or Q8. The SCR latches and lights
its associated LED indicator on the A 1 panel to indicate
which overload has occurred. All indicators that have been
lighted by an overload function remain lighted until OVLD

Change 5 4-17
THEORY OF OPERATION 816R-2C

4-5.7 Power Failure Recycle Board, A8Al. closed. L REAR DOOR INTLK indicator LED A1A1DSI4,
C REAR DOOR INTLK indicator LED A1AIDSI5, R
In the event of momentary loss of primary power, the power REAR DOOR INTLK indicator LED AIA1DSI7, C FR
failure recycle circuit restores the transmitter to operational PNL INTLK indicator LED AIAIDS18, and R FR PNL
status. Capacitor C3 maintains current flow through time INTLK indicator LED AIAIDS19 are panel interlock status
delay relay A8K4 keeping the time delay circuit active for indicators that are lighted when the respective panels are in
short term power outages and a separate circuit provides a place. Panel designations refer to the three bays of the
momentary ground at pin 10 when power is restored. The transmitter cabinet (left, center and right) as viewed from
momentary ground is applied to capacitor A2A5C22 and the the front of the transmitter. REMOTE INTLK indicator
charging current of this capacitor pulls relay A2A5K8 in LED AIAIDS20 is lighted when continuity exists between
and initiates the power ON command. remote control interface terminal board A 1OTB 1-3 and -4.
FAILSAFE INTLK indicator LED A 1A 1DS29 is lighted
4-5.8 Auto-Manual Power Control Latching Relay and when remote relay Al OA2K8 is energized. Indicator LEDs
Transmitter Status Indicators. AIAIDSl1 through AIAIDS21, except for AIA1DS16,
are in series and in sequence as they are connected in the
The latching relay permits local or remote selection of circuit. Therefore, an interlock must be satisfied before its
manual or automatic power control (Refer to Figure 4-11 status indicator LED will light.
and Status and Interlock Simplified Schematic, 189579, in
pouch at rear of manual). 4-5.9 Power Control Relays, PIO AI0A2.

The latching relay is connected to the remote control panel Assembly AI0A2 provides remote manual power lower and
I through terminal board A10A2. A 24 Vdc signal applied by raise control. When power is decreased at the remote
manual control switch A 1A 1S2 or through remote control control panel, relay K4 is energized (see Figures 4-8 and
interface board will latch relay Al OA2K2 in one of two 4-12). Closed contacts provide 115 Vac to motor A2A9Bl
stable states. AUTO PWR CONTROL switch LED which adjusts the resistance of A2A9R 1 to decrease the
A 1A 1S1 indicates automatic power control is selected and transmitter power output. When the power is increased at
MAN PWR CONTROL switch LED AIAlS2 indicates the remote control panel, relay K6 is energized and closed
manual power control is selected. contacts provide 115 Vac to motor A2A9B 1 which adjusts
the resistance of A2A9R 1 to increase the transmitter power
Visual indication of TRANSMITTER CONTROL output.
REMOTE/LOCAL switches A2A7S 1 or A2A7S2 are given
by status indicator LEDs A1AIDS22 and AIA1DSI6. 4-5.10 Remote Relays, PIO A10A2.

Plate control circuit interlock status indicators are provided


on the Control Panel AI. RMT PLT OFF INTLK indicator
LED AIAIDSII is lighted when remote relay AI0A2K8 is
Remote relays in Al OA2 parallel the front panel control
operations. Failsafe relay K8 is energized only when 24
Vdc is present in the control circuit. If the 24 Vdc is lost,
I
de-energized. PA GRID DOOR INTLK indicator LED the relay de-energizes and removes plate power from the
AIA1DS12 is lighted when the PA grid compartment door transmitter. Second power level (low power) relay K7 must
is closed. PA DOOR INTLK indicator LED AIAIDS13 is also be energized continuously (24 Vdc) to maintain this I
lighted when the power amplifier plate compartment door is function.

4-18 Change 5
816R-2C THEORY OF OPERATION

RELAY SHOWN IN MANUAL


(SET) POSITION

RESET
AUTO
A1A1S1
--L-
O~

11
POWER MAN. PWR.
MON/CTRL--(14 ~---+---~ A2A9R1
A2A6 13
9

11(17 IAUTO I
m I ' 4
8 I
PIa A1A1S1
+24V

~---t----~18

IMANUAL I
PIa A1A1S2

I
--l-
16
t------+- ~19 )>---------'0 a----,
MANUAL
A1A1S2
m
SET
: PIa A10A2K2 PIa TB1
R~~~~E';'~U'T'~' , , , , , , , , • • , , , • , , , • , , , r.,r',,·,"
10

94G0028

CONTROL 1 MAN.

Figure 4-11. Latching Relay Simplified Schematic.

Change 5 4-19
THEORY OF OPERATION 816R-2C

POWER CONTROL
RESISTOR

PIO
.
•••• II •••••••••• ••••••••• III

POWER ADJUST A 1A 1J2


A1A1S7 R2 : 0.01 uf
I
RAISE
1~35 ~
2 · 100 C 1

~34 I C2
81
9

1~36
-
LOWER I · 0.1 uf
PIO A2A9
A1A1S8
••••••••••••• It ••• IJ ••••• .,

120VAC FROM
A6XF11-2
•• ""." •• II II II •••••••••••••••••• " 6 ... II 5 ..
+24 6

POWER
1
RAISE

------+-----~ 3

8 6 9 11

13
POWER
9 I--+----< 1
LOWER
----¥I 0
TO K2

""--------l7 >-- A1A1J1-35


· PIO A10A2
93G0304

Figure 4-12. Power Control Reiays Simplified Schematic.

4-20 Change 5
816R-2C MAINTENANCE

SECTION 5 - MAINTENANCE

5-1. ROUTINE MAINTENANCE 1. Remove the cross-wire brace that holds the filter in place.

The transmitter is carefully inspected and adjusted at the 2. Remove the filter.
factory to reduce maintenance to a minimum. To ensure
peak performance, adhere to a regular schedule of periodic 3. Use a vacuum cleaner to remove heavy dust
checks and maintenance procedures. Refer to the parts lists, accumulation from the filter.
Section 6, for component location in the transmitter.
4. Blow a stream of air through the filter in a direction
opposite to normal air flow.
WARNING
5. Wash the filter in a solution of hot water and detergent.
HIGH VOLTAGES ARE EXPOSED WHEN
CABINET DOORS OR ACCESS PANELS ARE 6. Reinstall the filter when dry.
OPENED. WHEN WORKING INSIDE THE
EQUIPMENT, BE SURE THAT ALL CIRCUIT 5-2.3 Tube Cleaning.
BREAKERS ARE OFF AND THAT PRIMARY
POWER IS DISABLED AT THE WALL The power amplifier tube should be cleaned when a visible
DISCONNECT OR CIRCUIT BREAKER quantity of dust accumulates on the cooling fins of the tube.
UNLESS OTHERWISE DIRECTED. ALWAYS Carefully remove the tube from the socket and clean with a
SHORT ALL HIGH VOLTAGE TERMINALS TO dry, oil free jet of air.
GROUND WITH THE GROUNDING STICK
PROVIDED. FAILURE TO COMPLY MAY
RESULT IN DEATH ON CONTRACT. 5-3. INSPECTION

Inspect the transmitter at least once a week. Check all metal


5-2. CLEANING parts for corrosion and general deterioration. Examine
wiring and components for signs of overheating. Ensure that
Clean the transmitter when dust accumulation occurs all controls are operating smoothly. Inspect all connections
anywhere inside the equipment. A solvent of and tighten any loose nuts, screws, or bolts. Examine the
trichlorethylene may be used as a cleaning material. blower and cabinet fans for normal operation.

5-2.1 General Cleaning Procedures.


5-4. LUBRICATION
1. Remove dust from chassis, panels, and components with
a soft-bristled brush. The tuning and loading motor and the manual power
increase/ decrease motor are sealed and do not require
2. Remove foreign matter from flat surfaces and accessible lubrication. The cabinet inlet fan motor (B2) and the PA
, areas with a lintless cloth moistened with solvent. Dry cavity blower motor (B 1) bearings should be lubricated with
with a clean, dry, lintless cloth. SAE 10 oil as necessary or if required. I
3. Wash switch and relay contacts with relay contact
cleaner. Wash less accessible areas with solvent lightly 5-5. PARTS REPLACEMENT
applied with a small soft-bristled brush.
The following paragraphs present general descriptions for
5-2.2 Air Filter. the removal and replacement of certain component parts.

The air filter should be cleaned whenever a perceptible


quantity of dust and dirt accumulates on the filter element.
Remove and clean the filter as follows:

Change 5 5-1
MAINTENANCE 816R-2C

5-5.1 PA Tube, VI. TABLE 5-1. REQUIRED TEST EQUIPMENT

Name Description Manufacturer


1. Remove air guides (tube chimney) between the PA
and Model
blocker and the cabinet base. Loosen the two bands
(top and bottom only, never 106sen the center band) on Volt-ohm- Test Meter Fluke 77
PA blocking capacitor and slide it down over the PA milliammeter
tube.
AC Voltlneter oto 10 volts, 1% to 1 Weston 433
(true RMS)
2. Remove the anode lead.
Power Supply o to 28 volts DC, 6 amps Any

CAUTION RF Wattmeter 2.5 kW and 25 kW elements, Bird Thruline


50 to 125 MHz (or equivalent)

BE CAREFUL TO NOT BEND OR BREAK Thruline 0-1 kW element, 0-100 W Bird 43 (or
THE SOCKET'S FINGER CONTACTS.
FAILURE TO COMPLY MAY RESULT IN Wattmeter equivalent)
DAMAGE TO THE TUBE SOCKET.
DC Voltmeter Otol0kV,I%tol any

3. Carefully lift the tube (4CXI5,OOOA), and PA DC Ammeter oto 5 amperes, 1% to I any
blocking capacitor, out of its socket.

4. Reverse the procedure to install the replacement.


5-6.3 Troubleshooting the Power Controller.
5-5.2 Fuse Replacement.
1. Remove primary power from the transmitter and ground
Tum AC line breaker off before removing or installing high voltage components (Refer to Figure 5-1).
fuses.

WARNING
5-6. TROUBLESHOOTING VOLTAGE HAZARD

If the transmitter fails to operate properly, check each USE CARE WHEN SERVICING GATING
circuit in the order that it is made operative. Use the CARDS A2AI, A2, AND A3. 250 VAC IS
simplified schematics and the overall schematic in Section 4 PRESENT ON CARDS WHEN MAIN CIRCUIT
when needed. Normal control panel meter readings are BREAKER A6CB6 IS ON. FAILURE TO
provided in Tables 3-5 and 3-6. Efficiency graphs are COMPLY MAY RESULT IN SERIOUS
provided in Figure 3-7. PERSONAL INJURY.

5-6.1 Access Panel Interlock Switch.


2. Remove two of the three gating cards from the A2
The access panel interlock switches must be blocked open assembly.
to perform certain adjustment procedures. To block the
panel switch to open, push in on the plunger and insert two 3. Restore the primary power to the transmitter and tum
insulated blocks between the switch contactors. Remove the FIL ON.
insulated blocks before reinstalling the panel.
4. Place the transmitter in MANUAL POWER CONTROL
5-6.2 Test Equipment. and after the time delay has expired, turn PLATES ON.

Table 5-1 lists the test equipment necessary to maintain the


transmitter.

5-2
816R-2C MAINTENANCE

5-6.3 Troubleshooting the Power Controller. - Continued NOTE

NOTE

The transmitter plate and screen power supplies


The 24 V dc power supply is ON when both the
24V supply breaker and ac line breaker are ON.
Unless otherwise indicated, the POWER
I
will be operating with only one power phase CONTROL switch is set to MANUAL, the
applied in the following tests. The plate voltage, POWER switch is set to FORWARD, the AUTO
screen voltage, and RF power output will be lower RECYCLE switch is set to OFF, and all circuit
than usual. Exact voltages in these tests are breakers are set to ON during adjustment
unimportant. procedures.

5. Operate POWER CONTROL ADJUST and observe that


the plate voltage, plate current, and RF power output 5-7.1 Switch Adjustments.
change smoothly. Note the maximum plate voltage. If
the power controller phase under test is good, there 5-7.1.1 Air Interlock Switch, AI2SI.
should be no breaker trips, no unusual noise from the
power transformers and no building lights blinking. 1. Press the PLATE OFF and FILAMENT ON switches on
control panel AI.

CAUTION 2. Remove the rear panel behind the PA cavity.

REMOVE PRIMARY POWER FROM THE 3. Adjust the tension bolt on switch A 12S 1 so that the
TRANSMITTER EACH TIME A GATING green filament light goes out when the PA grid
CARD IS REMOVED. FAILURE TO COMPLY compartment door is opened approximately one inch.
MAY RESULT IN CARD DAMAGE.
5-7.1.2 Tuning Motor Limit Switches, A 12S II-S 14.
If none of the cards operate properly in the selected power
controller receptacle, use a different card receptacle and 1. Press the PLATE OFF and FILAMENT OFF switches
repeat the test. Perform the same test with each of the on control panel AI.
remaining gating cards in the same power controller card
receptacle. The results should be the same for each card if 2. Remove the rear panel behind the PA cavity, or the side
the card is good. If all the cards operated properly, use one panel next to the cavity.
of the cards to test each of the two remaining receptacles.
This will check the other two power controller phases. 3. Loosen the mounting screws on the limit switch.

If all cards operate properly in one or two receptacles but 4. Position the limit switch so that the peg mounted to the
not in another, it can safely be assumed that the cards are rack gear causes the switch to trip before the peg runs
good but either an A2 control transformer or one of the into either end-stop. The tuning and loading paddles
SCR banks are defective. Experience indicates that the must never be closer than 5/8 inch from the blocking
SCRs are least likely to fail. capacitor.

5-7.2 Filament Voltage Adjustment.


5-7. ADJUSTMENTS
1. Press the PLATE OFF and FILAMENT OFF switches
All transmitters are factory adjusted and pre-tuned to on the control panel Al 0

specific customer requirements. No adjustments are


required by the customer unless a broken part is replaced, a
specific assembly does not display meter readings within
allowable tolerances, or the transmitter is operated at a
frequency or power output different from the frequency or
power output specified in the production test data supplied
with the transmitter.

Change 5 5-3
MAINTENANCE 816R-2C

3 PHASE
ACINPUT

TRANSMITTER
* REAR VIEW OF
BREAKERS SHOWN
POWER ENTRY BLOCK


A 6CB6


A 6CB5 •
A6CB4 •
A6CB3

A 6CB2

F10

AC
1

Z1A Z1B
:EJ
Z1C A2E1-3

A2E1-1

A2E1-2

POWER 2 7 12 2 7 12
TRANSFORMER PA PLATE PA SCREEN
TAPS SHOWN TRANSFORMER T1 TRANSFORMER T2
FOR 210 VAC
4 9 14 4 9 14

93G0305A

Figure 5-1.. Primary AC Wiring, Power Control.

5-4
816R-2C MAINTENANCE

5-7.2 Filament Voltage Adjustment. - Continued 7. With S1 of the filament regulator card A2A4 in
MANUAL position, depress RAISE switch, A2A4S3,
and run variable transformer drive motor until limit
WARNING switch actuator arm is against the upper clockwise
VOLTAGE HAZARD (CW) limit switch.

HIGH VOLTAGES ARE EXPOSED WHEN 8. Adjust variable transformer A8A2TI with an insulated
CABINET DOORS OR ACCESS PANELS rod for an indication of 6.4 V ac. Note the filament
ARE OPENED. THE SHAFT OF meter reading. If filament meter does not agree with
VARIABLE TRANSFORMER A8A2Tl HAS calibration meter, adjust filament meter calibration
HAZARDOUS VOLTAGE TO GROUND A2A7RI until it does.
WHEN FILAMENT CONTACTOR IS
ENERGIZED. USE CARE WHEN 9. Press FILAMENT OFF switch on control panel AI.
PERFORMING THE FOLLOWING Tum OFF main circuit Breaker A6CB6.
PROCEDURES. FAILURE TO COMPLY
MAY RESULT IN PERSONAL INJURY. 10. Tighten setscrews on variable transformer end of
motor coupling.

2. Open the power amplifier grid compartment and 11. Place switch A2A4S 1 on the filament regulator card in
connect a 0 to 10 volt, true RMS ac, one percent MANUAL position.
meter, to the power amplifier filament rings on the
tube socket. 12. Turn main breaker A6CB6 back on. Press FILAMENT
ON switch on control panel AI.
3. Run the meter leads through the comer of the
compartment and close the power amplifier 13. Use the RAISE or LOWER switches, A2A4S2 and S3,
compartment door. on the filament regulator card to adjust the filament
voltage to the desired voltage, 6.0 V ac rms is the
4. Remove the cover from the control circuits card cage recommended operating voltage for 48 hours, as
and pull the plunger on the card cage interlock all the indicated on the true rms voltmeter.
way out. Tum main circuit breaker A6CB6 OFF.
14. Check the comparator window voltag~ on the filament
regulator card. It should be preset to 5.00 volts. If it is
WARNING not, adjust resistor R20 observing the voltage on
VOLTAGE HAZARD BLUE test point 2 (TP2) and adjust for 5.00 volts.
Once this voltage is set, it should not need to be reset
GROUND VARIABLE TRANSFORMER unless a component change is made.
(A8A2Tl) SHAFT AND CONTACT BRUSH
ASSEMBLY BEFORE TOUCHING ANY 15. Adjust resistor R2 for 5.00 volts by observing the
PART OF VARIABLE TRANSFORMER. voltage on RED test point 3 (TP3). At this point the
REPEAT THIS PROCEDURE EACH TIME green LOCK LED DS4 should illuminate.
POWER IS REMOVED. FAILURE TO
16. To adjust the timer, while still in the MANUAL
COMPLY MAY RESULT IN PERSONAL
position of switch S 1, push both RAISE and LOWER
INJURY.
switches (S3 and S2) simultaneously and time how
long the timer yellow indicator, DS 1, stays on: This
delay is normally set for 5 seconds at the factory to
5. Loosen motor coupling setscrews on variable
prevent momentary changes in the power line voltage
transformer A8A2Tl (Right side panel) end of
from constantly effecting a correction. To increase
coupling, and turn the main circuit breaker ON.
time delay adjust resistor R7 counter clockwise
(CCW); to decrease time delay adjust resistor R7 CWo
6. Press FILAMENT ON switch on control panel AI.
Repeating the above will verify your action. The time
delay range is approximately 0 to 12 seconds.

5-5
816R-2C

17. Once the above adjustments are made, activate the 26. After the filament voltage has been set, return the
automatic mode of filament voltage regulation by transmitter output power control to the AUTO position.
placing switch SI in the AUTO position. RAISE and Ensure that the filament voltage regulator is also in
LOWER switches S3 and S2 only operate in the MAN AUTO.
(manual) mode of operation.
5-7.3 DC Overload Adjustment.
18. The life of the PA tube can be greatly enhanced by
correctly adjusting the filament voltage required to 1. Press the PLATE OFF and FILAMENT OFF switches
produce the emission needed for your rated output on control panel AI. Turn DRIVER POWER SUPPLY,
power. To obtain the optimum tube life you should PA SCREEN POWER SUPPLY and PA PLATE
adopt the following procedure. POWER SUPPLY circuit breakers OFF.

19. First stabilize a new tube's emission by operating it at 2. Remove the front panel beneath the PA grid
the recommended filament voltage for 48 hours. compartment door.

20. Place the transmitter power control in the MANUAL 5-7.3.1 PA Plate Overload Adjustment.
position. Also place the filament voltage regulator in
the MANUAL position. 1. Connect an ammeter from the positive terminal of an
adjustable 28 V de power supply to resistor A5R8-1.
21. Raise the transmitter output power to 105% of normal
rated power. 2. Connect the negative terminal of the de power supply to
resistor A5R5.
22. Carefully lower the filament voltage in 0.2 volt steps,
pausing about 30 seconds after each step, look for a 3. Raise the de power supply current to 4.3 amperes.
greater than 2 0/0, change in output power or plate
current. This is the filament emission knee. Now raise
the filament voltage 0.2 volts above this voltage. This NOTE
is the correct filament voltage for your output power. The plate supply current is rated at 3.5 amperes.
This measurement point is the sum of the plate
and screen supplies and 4.3 amperes allows for
WARNING the 0.8 ampere screen supply.

REMOVE ALL POWER FROM THE


TRANSFORMER BEFORE WORKING ON 4. If overload does not occur, then adjust PA PLATE
THE VARIABLE TRANSFORMER LIMIT OVLD ADJ resistor A5RI6 to trip relay A5K3 at this
SWITCHES. FAILURE TO COMPLY MAY current. (The PA PLATE OIL fault indicator on the
RESULT IN PERSONAL INJURY. overload/recycle board lights when the relay trips.) If
overload trip occurs at less than 4.3 A, adjust resistor
A5RI6 to raise trip point to 4.3 amperes.
23. It may be necessary to adjust the lower limit of the
filament voltage variable transformer to find the knee 5. Disconnect the ammeter and remove the jumper from
and/or operate at the correct filament voltage. the de power supply to resistor A5R5.

24. After the correct voltage for desired operating power 5-7.3.2 FA Screen Overload Adjustment.
has been established, repeat Steps 13 through 17 and
reset the" desired voltage" to the correct leveL 1. Connect a milliammeter from the positive terminal of an
adjustable 28 V de power supply to terminal 3 of
25. Check for a change in the filament voltage knee one A5R15.
week later. Keep the operating voltage 0.2 volts above
the emission knee. Repeat this check monthly 2. Connect the negative terminal of the de power supply to
throughout the life of the tube. terminal 1 of A5R15.

5-6
816R-2C MAINTENANCE

5-7.3.2 PA Screen Overload Adjustment. - Continued 3. Press the FILAMENT ON and PLATE ON switches on
control panel AI.
3. Raise the power supply current to 800 rnA.
4. Raise or lower the POWER ADJUST control until
4. If overload does not occur, then adjust PA SCREEN approximately 8000 volts is indicated on the PLATE
OVLD ADJ resistor A5RIS to trip relay A5K2 at this VOLTAGE meter.
current. The PA SCRN OIL, fault indicator LED on Al
lights when the relay trips. If overload trip occurs at less 5. Set TEST METER select switch to PA SCREEN 800 V.
than 800 rnA, adjust resistor A5RI5 to raise trip point Observe that approximately 750 Volts is indicated on
to 800 rnA. the TEST METER.

5. Disconnect the milliammeter and remove the jumpers 6. Press the PLATE OFF and FILAMENT OFF switches
from the dc power supply to ASRI5. on control panel A 1 and Mute on the exciter.

6. Press the FAULT RESET switch on control panel AI. 7. Replace all panels and close all compartment doors.

5-7.4 PA Grid Current Meter Calibratiion. 5-7.6 IPA Metering Board Calibration.

1. Press PLATE OFF and FILAMENT OFF switches on 5-7.6.1 General Information. Necessary equipment for this
control panel AI. Tum DRIVER POWER SUPPLY, calibration includes: Bird Thruline wattmeter with SOO-watt
PA SCREEN POWER SUPPLY and PA PLATE and lOa-watt elements, ammeter with a to 30 A dc rating
POWER SUPPLY circuit breakers OFF. and inductive sensor, digital voltmeter, Bird SaO-watt
dummy load, 50-ohm coaxial cable with Type N cable
2. Remove the front panel beneath the PA grid connector and adapters: male-to-male and
compartment door. female-to-female.

3. Connect the negative terminal of an adjustable 28 V dc


power supply to ASEI3 and the positive terminal to WARNING
ASEI2.
TURN TRANSMITTER POWER OFF OR
4. Adjust the dc power supply current to 100 rnA. DISCONNECT IT WHEN CONNECTING OR
REMOVING TEST EQUIPMENT AND
5. Set the TEST METER selector switch to PA GRID 400 OTHER TEST COMPONENTS. HIGH
rnA. VOLTAGES AND HIGH POWER RF
SIGNALS ARE PRESENT. FAILURE TO
6. Adjust PA GRID MTRG CAL CONTROL resistor COMPLY MAY RESULT IN PERSONAL
A5RI8 for a 100 rnA reading on the test meter. INJURY.

7. Remove the dc power supply test leads.


5-7.6.2 Setup Procedures.
5-7.5 High Voltage Power Supply Static Check (no drive).
1. Refer to FM Broadcast Exciter 802B Instruction
Manual and adjust exciter power output to 15 watts.
WARNING
2. Set PA SCREEN and PA PLATE POWER SUPPLY
HIGH VOLTAGES ARE EXPOSED WHEN circuit breakers on Circuit Breaker Panel (Figure 3-5) to
CABINET DOORS OR ACCESS PANELS ARE OFF.
OPENED OR REMOVED. FAILURE TO
COMPLY MAY RESULT IN PERSONAL
INJURY.

10 Remove the lower front panel below the exciter and


block open the interlock switch.

2. Press the MUTE button on the exciter.

5-7
MAINTENANCE 816R-2C

5-7.6.2 Setup Procedures. - Continued WARNING

3. Set AC LINE circuit breaker on circuit breaker panel HIGH VOLTAGE MAY BE PRESENT ON
(Figure 3-5) to OFF. EXPOSED ELECTRICAL TERMINALS OR
CONDUCTORS OF THE TRANSMITTER.
4. Remove lower front access panel of center cabinet. USE CAUTION WHEN WORKING NEAR
Block interlock switch for the panel so that it is EXPOSED TERMINALS OR CONDUCTORS.
bypassed. FAILURE TO COMPLY MAY RESULT IN
PERSONAL INJURY.
5. Remove four retaining screws and slide the IPA drawer
and attached cables out from front of cabinet.
6. Use digital voltmeter to measure voltage at
6. Set IPA metering assembly controls (Figure 6-11) as A3ARI TB 1-6. Record measurement.
follows:
7. Press Ee 60 VFS switch on IPA metering board A3AI.
R22 VSWR THRESHOLD INDICATOR Fully CW
R27 COLLECTOR CURRENT CAL Fully CCW 8. Adjust A3AIR32 on IPA metering board so that
R32 COLLECTOR VOLTAGE CAL Fully CCW voltage shown on meter matches that measured in step I
R23 FORWARD POWER CAL Fully CCW 6 above.
R14 REFLECTED POWER CAL Fully CCW
9. Slowly adjust exciter output so that power output of
7. Disconnect coaxial cable from output of the IPA. IPA as shown on Thruline wattmeter is 500 W.

10. Press FWD 1,200 WFS switch on IPA metering board


NOTE A3Al.

In the following step, the DC coupler (A3DCl) is 11. Adjust A3AIR23 on the IPA metering board so that I
to remain in place at the IPA output. power output shown on the meter is 500 W (forward
power meter scale is 0 to 1,200 W).

8. Connect input of Thruline wattmeter with 500 W


element to IPA. Use appropriate coaxial adapter(s) and WARNING
50 ohm cable. Connect input of Bird 500 W dummy load
to output of wattmeter with appropriate adapter(s) and DANGEROUS VOLTAGES AND RF SIGNALS
cable. ARE PRESENT IN THE TRANSMITTER.
AVOID CONTACT WITH TERMINALS OR
5-7.6.3 Calibration Procedures. CONDUCTORS. FAILURE TO COMPLY
MAY RESULT IN PERSONAL INJURY.
I. Set AC LINE circuit breaker Figure 3-5 to ON.
12. Press Ie 30 AFS switch on the IPA metering board.
2. Set BLOWERS circuit breaker, and 28 V de and
DRIVER POWER SUPPLY circuit breakers, on circuit 13. Position inductive sensor of 0 to 30 ampere ammeter
breaker panel (Figure 3-5) to ON. around the wire attached to terminal A3ARITBI-6.
Record this measurement.
3. Press POWER CONTROL MAN and FILAMENT ON
switch/indicators on control panel (Figure 3-2). 14. Adjust A3AIR27 on IPA metering board (Figure 6-28) I
so that current measurement shown on the meter
4. When READY indicator on PA control panel matches that recorded in Step 13 above.
illuminates, set PA SCREEN and PA PLATE POWER
SUPPLY circuit breakers on circuit breaker panel to
ON.

5. Press PLATE ON switch-indicator on control panel to


ON (lighted) condition.

5-8 Change 5
816R-2C MAINTENANCE

5-7.6.3 Calibration Procedures. - Continued established in Step 28 above. Directional coupler is to be in


its normal forward configuration.
15. Adjust exciter output until a measurement of 100 watts
in shown on Thruline wattmeter. 32. Perform Steps 2 through 5 above.

16. Press PLATE OFF switch on PA control panel (Figure 33. Verify that output of IPA as shown on meter of IPA
3-2). Press FILAMENT OFF switch. metering board (Figure 3-6) is 500 ±50 watts. Slight
adjustments may be made to the exciter output if
17. Set PA PLATE, PA SCREEN, DRIVER, and 28 V dc necessary.
POWER SUPPLY circuit breakers on circuit breaker
panel (Figure 3-5) to OFF. 34. Perform Steps 16 and 17 above. Then set AC LINE
circuit breaker on the circuit breaker panel (Figure 3-5)
18. Disconnect cable and adapter from IPA. to OFF.

19. Disconnect directional coupler A3DCl from the IPA.


Reverse coupler and use appropriate adapter to reinstall WARNING
it in the reverse mode.
GROUND ALL CAPACITORS AND
20. Reconnect Thruline wattmeter cable and adapter to the CONDUCTORS IN THE TRANSMITTER
IPA. BEFORE PERFORMING THE FOLLOWING
STEPS. FAILURE TO COMPLY MAY
21. Perform Steps 2 through 5, above, to re-power the RESULT IN PERSONAL INJURY.
transmitter.
35. Slide the IPA drawer (Figure 3-1) into transmitter.
22. Verify that output of IPA is still 100 watts as Attach with four screws.
established in Step 15 above.
36. Unblock interlock switch for access panel of lower
23. Press REFL 1,200 WFS switch on IPA metering board. compartment of transmitter center cabinet. Install access
panel.
124. Adjust A3AIR14 on IPA metering assembly (Figure
6-28) until a measurement of 100 watts is shown on the 5-7.7 FWDIREFL CAL and Power Control Card, A2A6.
meter.
NOTE
25. Press FWD 1,200 WFS switch on IPA metering board.
Maintenance is required only if major part
126. Adjust A3AIR22 on IPA metering board CCW until the damage has occurred. Adequate test equipment
VSWR light on the IPA metering board just comes on. is required for proper, accurate alignment.

27. Perform Steps 16 through 21 above. 5-7.7.1 Offset Nulls.

28. Adjust exciter output (Figure 6-28) until the Truline


wattmeter indicates 500 watts. WARNING

29. Perform Steps 16 and 17 above. USE CARE WHEN SERVICING GATING
CARDS A2AI, A2, AND A3. 250 VAC IS
30. Disconnect Thruline wattmeter and dummy load from PRESENT ON CARDS WHEN MAIN
output of IPA. CIRCUIT BREAKER A6CB6 IS ON. FAILURE
TO COMPLY MAY RESULT IN SERIOUS
31. Reconnect coaxial cable so that grid input circuit of PERSONAL INJURY.
power amplifier is connected to output of driver. Be
sure directional coupler A3DC1 is still in configuration

Change 5 5-9
816R-2C

5-7.7.1 Offset Nulls. - Continued NOTE

1. Place the A2A6 card on the extender board. Tum ON Reflected Power (VSWR) trip point is factory
only the transmitter filaments and allow the components adjusted to 100/0 of rated transmitter power or
to temperature stabilize for at least 15 minutes. 100/0 of TPO if factory is advised of TPO. This
level may not be desired and must be set by
2. Use a high impedance dc voltmeter to measure the station engineer to the desired safe level.
voltage at test point TPI. Adjust resistor R9, FWD
OFFSET, set for zero voltage at test point TPI.
3. Adjust resistor R2, REFL CAL, to indicate 10%
3. Use a high impedance dc voltmeter to measure the reflected power. Full scale is 120/0 when reflected power
voltage at test point TP2. Adjust resistor RI, REFL is selected. DO NOT ADJUST THIS CONTROL
OFFSET, for zero voltage at test point TP2. AGAIN.

4. Use a high impedance dc voltmeter to measure the 4. With plates OFF, depress TEST switch, SI, and adjust
voltage at U2-6, most easily accessible at either end of resistor R3, REFL ADJ, for desired reflected (VSWR)
resistor R27. Adjust resistor R6, OFFSET ADJUST, for level indication on panel power meter AIM4. Full scale
zero voltage at U2-6. is 12%. Nuisance trips may occur if the trip level is set
for less than 5%.
5-7.7.2 Forward Power Calibration.
5. Place VSWR PROT jumper ON and adjust resistor R4
1. Adjust the transmitter to normal power output using the VSWR PROT CAL until a VSWR Overload occurs.
manual power control. An indirect power calculation
may be used if an external power meter is not available. 6. Remove all voltage, return the top element and VSWR
PROT switch to normal.
2. Adjust resistor RIO, FWD CAL, to indicate 100% on
the OUTPUT POWER meter AIM4. DO NOT 5-7.7.4 VSWR Foldback Adjustment.
ADJUST THIS CONTROL AGAIN. Increase the
power control to maximum output power. Refer to the
test data for proper plate screen and driver transformer NOTE
taps if the maximum power output exceeds 1050/0. The
maximum power should not exceed 105% unless The Foldback Circuit is not enabled when the
unusual circumstances exist. transmitter is shipped from our factory . There
is the possibility of additional damage to a
3. Switch to AUTO power control and adjust resistor R8, previously damaged antenna system where the
PWR CNTRL ADJ, for 100% power in the AUTO Foldback circuit is in use. The Foldback level
mode. should be set to the fully CCW position unless
antenna icing conditions are likely.
14. Apply 24 V dc to terminal board AIOTB2-1 to activate
relay AIOA2K7.
1. Pull VSWR PROT jumper OFF. Switch to AUTO
5. Adjust resistor R7, LP ADJUST, to the desired second power control, and depress the REFL switch.
power level.
2. Remove the low power element from the top, reflected
5-7.7.3 Reflected Power and VSWR Protection Calibration. power position of the directional coupler, DCI.

1. Use the manual power control to reduce the power 3. Remove the high power element from the bottom,
output to 10% of the desired operating TPO. forward power position of the directional coupler, DCI,
and install it in the reflected power position with the
2. Pull the VSWR PROT jumper OFF and reverse the element arrow pointing toward the load.
direction of the top element in the directional coupler 9

DCI.

5-10 Change 5
816R-2C MAINTENANCE

5-7.7.4 VSWR Foldback Adjustment. - Continued the desired output power. To complete the power change,
refer to Paragraphs 5-7.7, 5-9.3, and 3.3, Step 25.
4. Tum the plate voltage ON, and in AUTO power mode,
adjust R5 VSWR FOLDBACK LEVEL to the desired
foldback level. Read the reflected power on the 120/0 5-9. CHANGING FREQUENCY
scale. Disregard the fact that the forward element is not
calibrated for the reflected power meter. This test only NOTE
requires a voltage that is controlled by the power
controller and represents some amount of reflected If power and frequency are to be changed, refer
power. Foldback level must be approximately half to Power Change, Paragraph 5-8, and change
VSWR trip level or less. transformer taps as directed, then return to this
paragraph to complete the frequency change
5. Remove plate voltage, return the high power and low procedure. Major RF tuning is required only
power directional coupler elements to their proper when components in the RF circuit are replaced
sockets and direction. Return the VSWR PROT jumper or when the operating frequency is changed.
to ON and resume normal transmitter operation. Refer to the initial turn-on procedures
(Paragraph 3-3 Steps 19 through 27) for minor
5-7.8 Phase Monitor Adjustment. tuning instructions.

WARNING The following paragraphs provide procedures for major RF


tuning of the transmitter. If the operating frequency is the
same as the frequency specified in the production test data
HIGH VOLTAGES ARE EXPOSED WHEN supplied with the transmitter, perform the procedures in
CABINET DOORS OR ACCESS PANELS ARE Paragraphs 5-9.2, Steps 1 through 10. If the operating
OPENED. USE EXTREME CARE WHEN frequency is different from the frequency specified in the
PERFORMING THE FOLLOWING production test data supplied with the transmitter, perform
PROCEDURES. FAILURE TO COMPLY MAY the procedures in Paragraphs 5-9.1 through 5-9.3.
RESULT IN PERSONAL INJURY.

NOTE
1. Remove primary power and the right front bay access
panels. Locate phase loss relay A8K5. The data presented in the graphs (Figures 5-2,
5-3 and 5-4) is approximate and is intended only
2. The phase loss/phase rotation monitor will shut off the to get the transmitter tuning close.
transmitter when phase loss or incorrect sequence is
detected. A phase loss will be detected if the line 5-9.1 Frequency Change Adjustments.
voltage drops below the threshold voltage level which is
set by turning the control on relay K5. The threshold NOTE
voltage range is 190 to 270 volts. Set control to 190
volts, full counterclockwise (CCW). These adjustments are not necessary if the
related components have not been replaced and
30 Replace primary power and right front access panels. the operating frequency is the same as the
frequency specified in the production test data
supplied with the transmitter.
5-8. CHANGING POWER
5-9.1.1 Shorting Plane.
The power output is adjusted by changing taps on the screen
transformer T2. The PA plate voltage is maintained high 1. Press the PLATE OFF and FILAMENT OFF switches
(8.2 to 8.7 kV) to keep efficiency high. Use the following on control panel AI.
data supplied in Sections 2 and 3 as a guide: Tables 2-1, 3-5
and 3-6, and Figure 2-5. Adjust the screen voltage to obtain

5-11
MAINTENANCE 816R-2C

5-9.1.1 Shorting Plane. - Continued 2. Tighten the screw on the adjustable plate.

2. Open the plate cavity doors. 5-9.1.5 Cathode Return Capacitor. Cathode capacitor slot
position definition: There are seven capacitor positions
3. Adjust the plate cavity slider deck (Figure 4-7) to the defined for each side of the four cathode return capacitors.
desired frequency in accordance with the graph in The seven positions are chosen to be easily identified by
Figure 5-2. eye. The positions are described below and in Figures 5-7,
5-8, and 5-9.
5-9.1.2 PA Neutralization. Adjust the PA neutralization
bars to the desired frequency in accordance with the graph Initially set the capacitor to the nearest whole position
in Figure 5-3. indicated above. The final position of the capacitor may be
fine adjusted for improved efficiency after the transmitter is
5-9.1.3 PA Grid Tuning Slider. operating.

10 Open the PA grid compartment door. 5-9.1.6 Efficiency Capacitor. Preset the efficiency
capacitor A12A3C39 for minimum capacitance. The
20 Adjust the PA grid tuning sliders (Figures 5-4 and 5-5, capacitor plates should be completely unmeshedo
Ll, 2, 3) in accordance with the graph shown in Figure
5-4 for the desired frequency. 5-9.1.7 Coupling Capacitor. Preset the coupling capacitor
(Cl) for minimum capacitance. The capacitor plate should
5-9.1.4 PA Grid Swamping Capacitor. be completely unmeshed. Close the grid compartment door.

10 Swamping capacitor A12C3 consists of two aluminum 5-9.1.8 PA Bias. Preset the bias resistor (R35), located
plates separated by some distance. The position of the behind the power amplifier cavity, to the middle of its range.
plate nearest the front of the transmitter is adjustable,
thus making it possible to set the distance between the
two plates. Referring to Figure 5-6, loosen the screw on (Continued on Page 5-21)
the adjustable plate and position it to obtain the plate to
plate spacing indicated in Figure 5-6 for the desired
operating frequency. The spacing may be checked by
using a drill bit or a similar device inserted between the
plates.

5-12
816R-2C MAINTENANCE

18
~
(f) ~
W ~
I17 ~
() ~
~
Z I'
Z 16 ~

"' ~
I'

"', "'
X ~
'-"15
W
()
Z ~
« 14
J-
(f)
0 13 DATA DATE
""'" "' ~
DECEMBER 1993

88 90 92 94 96 98 100 102 104 106


FREQUENCY IN MHz

SLIDER DECK

v
/
r
(X) I
"
I
V
TUBE SHELF

l /
93G0306

Figure 5-2. PA Plate Tuning Cavity Slider, Coarse Adjustment.

5-13
MAINTENANCE 816R-2C

SCREEN RING
PA CAVITY FLOOR
o

o o

TUBE SOCKET
NEUTRALIZING CLAMPS

3
(J)
w
I
U DATA DATE
~ 2 "'----

0- DECEMBER 1993
w
u
z« 1
t-
C/)
o
o
88 90 92 94 96 98 100 102 104 106 108
FREQUENCY (MHz)

Figure 5-3. PA Neutralizing Adjustment. 93G0307

5-14
816R-2C MAINTENANCE

CJ)
-........ .............
~2 ............. --- ......
o .............
z ............. ..............
~
z .............
............. -.
0- --. .............
w ............. .............
o ~
z .............
............. -.-
~ 1 ~
CJ) ~ ............
(5

DATA DATE
DECEMBER 1993

o I I I I
88 90 92 94 96 98 100 102 104 106 108
FREQUENCY IN MHz

C7, 8,9

C10,11,12
C4, 5,6
r--------------I-:---~~....-------------.


(D)

t
•,
(D)

9380308

Figure 5-4.. Graph for Coarse Setting of PA Grid Tuning Inductors.

5-15
MAINTENANCE 816R-2C

C6 C5 L1 C4

C39
C58

C7
FILAMENT
ED
- LEAD

C8
-
(±)

L2
ED
-
C9

C60
@

FILAMENT
LEAD

C10 L3 C11 C12


93G0309

Figure 5-50 Power Amplifier Tube Socket (Bottom View), A12A3.

5-16
816R-2C MAINTENANCE

0.6

0.5
~
(j)
w
0.4 ~
,,-

~
I
0
z ../
0.3
0
/
~
0.2 DATA DATE
DECEMBER 1993

0.1

o
85 90 95 100 105 110
FREQ MHz

93G0310

Figure 5-6. PA Grid Swamping Capacitor.

5-17
MAINTENANCE 816R-2C

D C58
PA SOCKET
BOTTOM VIEW
C53 SIMPLIFIED

o
e60

C59

Q
FRONT OF TRANSMITTER

93G0311

Figure 5-7.. PA Socket, Cathode Return Capacitors.

5-18
816R-2C MAINTENANCE

SCREW HEAD

OUTSIDE
SLOT ________

~INSIDE
SLOT CENTER
OF SOCKET
C53, C58, C59, C60
DOOR KNOB TYPE
CATHODE BYPASS 93G0312

CAPACITORS

Figure 5-8. Adjustment of Cathode Return Capacitors.

5-19
MAINTENANCE 816R-2C

a:
~
6

5
"'"~ is/O~

'~/-<S'0~
~
~
Z
z 4
o
i=
Cf)
o0... 3
" ~-
INSIDE
-- - I

f----- DATA DATE


DECEMBER 1993
'"~ /-00~

I
85 90 95 100 105 110 93G0313

FREQUENCY MHz

TOP (INSIDE)

I
- \
I

-
I
,
\

BonOM (OUTSIDE)

POSITION NUMBER
2 3 4 5 6 7

93G0314

Figu~e 5-9" Cathode Return Capacitor Position vs. Frequency"

5-20
816R-2C MAINTENANCE

5-9.1.9 IPA to PA Cable Length. The length of the coaxial procedure allows you to tune the grid circuit using the
cable between the IPA directional coupler (A3DC 1) and the output of the exciter.
PA cavity input connector shall be cut to a specific length
based on the desired operating frequency. The cable must 10 Use a coax cable and BNC to Type-N adapter to

I
be type RG-142. It can be obtained from CE by ordering art
number M17/60-RG142. Use the illustration in Figure 5-10
to calculate the cable length.
connect the exciter RF output directly to the grid input
circuit. This bypasses the IPA.

2. Tum the transmitter plate breaker CBS OFF.


45
I
3. Tum filament and plate control ON. After the filament
" IPA COAX LENGTH
time delay, there will be IPA collector voltage but no
40
",,\ 816R-1C, 2C. 3C & 4C
(DUAL 400W MODULES) IPA collector current. There will be no PA plate
I' voltage or screen voltage since the plate breaker is
~
~ OFF.

35 "'\ , 4. Set the exciter RF output level to approximately 15


watts.
\.

30
"'" , 5. Adjust the PA grid TUNING and COUPLING
controls for minimUITI indication on the exciter
r, reflected power meter.
r\.
~

25 " 6. Increase the exciter RF output to approximately 40


" watts and repeat Step 5.
" r\.
\.
'-
7. Tum plate and filament control OFF and remove
20
" primary power from the transmitter. Restore the

" exciter and IPA to original configuration. Tum plate


breaker CB5 ON.
o
85 90 95 100 105 110
FREQUENCY (MHz)
NOTE

Figure 5-10. IPA to PA Cable Length. The PA tube input impedance decreases as
the grid input power is increased. The grid
5-9.1.10 P.lL\. Grid Circuit. There are several reasons for tuning and coupling must be readjusted when
adjustment of the PA grid tuning and coupling circuits, for the IPA is reconnected and the IPA output
example: power is increased to normal.

Ao When the IPA module fails and is replaced.


The following steps shall be performed starting with low
Bo When the tube is replaced. IPA output power and zero or minimum plate voltage.
Adjust grid tuning and coupling as drive power is slowly
C. If there is any reason to suspect that there may be a increased until normal drive power is reached and then
bad load on the IPA or if changes have been made in slowly increase plate voltage while adjusting the grid tuning
the PA grid circuit. and coupling until normal operating plate voltage is
reached. Keep the IPA reflected power to a minimum while
When the IPA internal VSWR protection circuits are active, making adjustments to IPA power output and plate voltage.
the IPA output power will be reduced and the fault lamp
illuminated. This can make grid tuning difficult if the grid is 8. Restore primary power to the transmitter and tum the
far out of tune. The 802B Exciter can be used to adjust the filament control ON.
grid circuit to approximately correct tuning and coupling
positions. The 802B Exciter has a reflected power foldback 9. Set the exciter power output adjustment fully CCWo
circuit that limits the reflected power to a safe level for the
exciter regardless of the VSWR presented to the exciter by
the PA grid circuit. The first six steps of the following

Change 5 5-21
MAINTENANCE 816R-2C

5-9.1.1 0 PA Grid Circuit. - Continued (See Figure 4-7.) Adjust the PA TUNING control on the
control panel until the capacitor is positioned approximately
10. Mute the exciter. Turn ON the plate control and mid-range. Close the plate cavity door.
reduce the plate voltage to zero or minimum with the
manual power control. NOTE

11. Dnmute the exciter. Slowly increase the exciter output An easier way to determine position of
while watching the IPA reflected power. Do not let the capacitors Al2CSl and A12C50 is to look at
IPA reflected power exceed 60 watts. the capacitor motor drive units. Each has a
limit switch actuator bar that travels with the
12. Adjust the PA grid tuning and coupling for minimum capacitor plate. When it is in the middle of its
IPA reflected power as the exciter output is increased range so are the capacitors. Left side and
to normal. DO NOT exceed 35 watts of output power center rear covers must be removed.
from the exciter. The normal range of IPA collector
current is 15 to 20 amperes.
CAUTION
13. Slowly increase the plate voltage with the manual
power control. Notice that the IPA reflected power DO NOT EXCEED THE FOLLOWING
will increase as the plate voltage is increased. Adjust MAXIMUM RATINGS, FAILURE TO
the grid tuning and coupling to keep the IPA reflected COMPLY MAY RESULT IN DAMAGE TO
power at minimum and IPA forward power at THE TRANSMITTER:
maximum as the plate voltage is increased toward
maximum. PA SCREEN CURRENT: 600mA
PA PLATE CURRENT: 3.5 A
14. This completes the adjustment procedure. Restore the
transmitter to normal configuration.
4. Place power control in MANUAL mode.
5-9.2 PA Tuning and Loading.
5. Press the FILAMENT ON and PLATE ON switches
1. Press PLATE OFF and FILAMENT OFF switches on on control panel AI.
control panel AI.
CAUTION
2. If possible, connect the transmitter to an RF
Wattmeter/dummy load combination or a calorimeter MAXIMUM PA TUBE PLATE
capable of measuring and dissipating 21.5 kW at 88 to DISSIPATION IS 15 KW. PROLONGED
108 MHz. If these devices are unavailable, refer to the TRANSMITTER OPERATION WITH THE
RF OUTPUT on the control panel for measurement. PLATE IMPROPERLY TUNED MAY
June 1, 1995 DAMAGE THE POWER AMPLIFIER.
CAUTION CALCULATE THE PLATE DISSIPATION
USING THE FORMULA BELOW. FAILURE
DO NOT PERFORM THE REMAINDER OF TO COMPLY MAY RESULT IN POWER
THIS PROCEDURE IF THE AMPLIFIER DAMAGE.
TRANSMITTER IS NOT CONNECTED TO
AN ANTENNA WITH A 50-OHM
IMPEDANCE OR A DUMMY LOAD
CAPABLE OF DISSIPATING AT LEAST 35
KILOWATTS. FAILURE TO COMPLY Where: D p is plate dissipation in Watts
MAY RESULT IN DAMAGE TO THE I p is DC plate current in amperes
TRANSMITTER. E p is DC plate voltage in volts
Op is RF output power in Watts
3. Open the plate cavity access door and observe PA
tuning and loading capacitors A12C51 and A12C50.

5-22
816R-2C MAINTENANCE

5-9.2 PA Tuning. - Continued A. REGENERATIVE (Positive Feedback)

6. Alternately adjust the PA GRID TUNING (Al2C2) B. PERFECTLY NEUTRALIZED (No


and COUPLING (AI2Cl) capacitors for minimum Feedback)
reflected IPA reflected power. The power amplifier
grid current should be at least 80 rnA. C. DEGENERATIVE (Negative Feedback)

7. Adjust the PA TUNING and PA LOADING controls The state of neutralization can be identified by observing the
for a maximum output power indication. control grid current while raising the plate tuning.

8. Repeat Steps 6 and 7 until maximum output power is


obtained. If the PA TUNING control encounters an If Grid Current State Of Neutralization
end-stop while in the LOWER position, lower the
shorting plane and retune. If an end-stop is encountered Rises Regenerative
in the RAISE position, raise the shorting plane and Doesn't change Perfect
retune. Drops Degenerative
NOTE

Because of the relatively high output capacity Experience has shown that it is best to adjust the
of the 4CX15,OOOA tube and the resulting low neutralization slightly beyond the point of perfect
cavity inductance, no plate current dip will be neutralization into the region of degeneration. Moving the
noted at higher power levels. Tuning and neutralization bars out slightly, 1/16" to 1/8", from the point
loading should be adjusted in steps for of perfect neutralization will place the PA into the
maximum output power. Perform procedure in degenerative region.
Paragraph 3-3, Step 25, for best efficiency.
NOTE
9. Check for power amplifier neutralization. Refer to
Paragraph 5-9.3. Check the transmitter for proper neutralization.
NOTE If neutralization is correct, do not perform this
procedure.
Compare the transmitter operating
parameters with those in Tables 3-5 and 3-6.
Some fine tuning of the previously preset 1. Press the PLATE OFF and FILAMENT OFF switches
adjustments may be needed to bring operating on control panel AI.
parameters into agreement with those found in
the data. If efficiency needs improvement, 2. Open the PA cavity door. Short all high voltage
adjustment of the efficiency capacitor terminals with grounding stick.
(A12A3C39) may be needed.
3. Remove front half of tube air guide to gain access to
10. Press the PLATE OFF and FILAMENT OFF switches screen sliders.
on control panel AI.
4. Refer to Figure 5-3 and adjust the screen sliders ~1 and
11. Determine if plate tuning capacitor A 12C50 is L N2 • The sliders should not require an adjustment greater
approximately halfway between its limits. than ±1/4 inch from the initial setting. (A setting on the
plus side is preferred.)
12. If plate tuning capacitor A 12C50 is not approximately
half way between its limits, adjust the PA plate cavity 5. Install the tube air guide.
shorting plane (Paragraph 5-9.1, Step 1) and repeat
Steps 3 through 12 of this paragraph. 6. Close the cavity door and apply power to the
transmitter.
5-9.3 PA Neutralization.
7. Check for proper neutralization again. If incorrect,
The power amplifier of the transmitter can be found in one repeat Steps 2 through 6.
of three possible states of neutralization (neut). These are:

5-23
MAINTENANCE 816R-2C

(This Page Intentionally Left Blank)

5-24
816R-2C PARTS LISTS

SECTION 6 - PARTS LISTS

6-10 INTRODUCTION 6-4. PART NUlVIBER

This section contains a list of repairable/replaceable Continental Electronics (CE) specification or drawing
electrical, and selected mechanical parts for the 816R-2C, control numbers for each item in the parts listings, are
I
FM Transmitter. Paragraphs 6-2 through 6-4 describe the reilected in this column.
three columns in the parts lists.

6-5. ILLUSTRATIONS
6-2. REFERENCE DESIGNATIONS (REF DES)
Parts listed in the REF DES column are located on
This column contains the electrical reference designators of corresponding illustrations. The illustration always precedes
parts that have been assigned on schematics or wiring the parts list. More than one illustration may be required to
diagrams, and/or index numbers for parts which have not identify all items in an assembly. When a replaceable item
been assigned reference designators. When a reference is hidden from view by structural parts or wiring, a dotted
designator within a series of designators has not been leader line is used to show the items location on the
assigned a part number, the unassigned reference designator illustration.
will be omitted from the list.

6-6. INDEX OF PARTS LISTS


6-3. DESCRIPTION
Table 6-1 is an index of major subassemblies used in the
The identifying noun or item name followed by a brief type 816R-2C Transmitter. The subassemblies are
description such as size, color, rating or special sequentially listed. The flfst parts list will cover items not
characteristics will be listed in this column. The included in a specific subassembly.
description for electrical/electronic parts includes the
application ratings and tolerances.

Table 6-1. Index of Parts Lists..

Ref. Des. Description/Title Part No. Rev. Page

Transmitter, 816R-2C, 21.5 kW FM 180295-2 N 6-5 I


Main Cable 180328-1 B 6-7
Al Control Panel 189638-1 6-9
AlAI Control Panel Circuit Card Assembly 189668-1 D 6-11
A2 Card Cage Assembly 180299-2 F 6-19
A2A4 Filament Regulator Circuit Card Assembly 182901-1 E 6-21 I
A2A5 OverloadlRecycle Circuit Card Assembly 180166-1 G 6-27
A2A6 Power Monitor/Control Circuit Card Assembly 180161-1 G 6-31
A2A7 Card Cage Component Circuit Card Assembly 189620-1 E 6-37
A2A8 Backplane Circuit Card Assembly 180194-1 G 6-41
A2A9 Power Control Assembly 172715-1 B 6-43 I
A3 Intermediate Power Amplifier Assembly. 180302-2 G 6-45
A3Al Metering Card Circuit Card Assembly 195079-1 A 6-47
A3A2 IPA Status Assembly 189625-1 A 6-49
A3A3 Amplifier Assembly 193773-1 H 6-51 I
A3A3AI-A2 Amplifier Module 189215-1 D 6-53
A3A3AI-A2A1 RF Circuit Card Assembly 189213-1 E 6-55
A3A3AI-A2A2 Control Circuit Card Assembly 189210-1 C 6-57

Change 5 6-1
PARTS LISTS 816R-2C

Table 6-1 . Index of Parts Lists. - Continued

Ref. Des. Description/Title Part No. Rev. Page

A4 (See 802B FM Exciter Manual)


A5 Component Shelf Assembly 180317-3 P 6-61
A5A1 IFA Metering Circuit Card Assembly 180386-1 A 6-65
A6 Circuit Breaker Assembly 180303-1 6-67
A7 Low Pass Filter Assembly 786-3451-003 F 6-71
A8 Component Panel Assembly 180320-1 E 6-73
A8AI Power Failure Recycle Circuit Card Assembly 640-3466-001 B 6-75
A8A2 Variac Driver Assembly 648-8104-001 E 6-77
A9 SCR Assembly 180304-1 6-79
AID Power Supply Assembly 180318-1 H 6-81
AIOA1 Bias Component Circuit Card Assembly 180383-1 A 6-83
AIOAl Remote Control Circuit Card Assembly 180310-3 A 6-85
All NOT-USED
Al2 PA Cavity Assembly 786-3335-005 AR 6-89
A12Al Metering Multiplier Circuit Card Assembly 643-7445-001 C 6-93
A12Al Metering Multiplier Circuit Card Assembly 643-7446-001 B 6-95
A12A3 PA Tube Socket Assembly 786-3686-002 H 6-99
AI3 Bleeder Resistor Assembly 180394-1 6-101

6-2 Change 6
816R-2C PARTS LISTS

P C1-B
DC1
DC1-A (DIODE PIN: 353-5376-010)

A12 A4 AS

A6

.~~~EmB
C2 A8
0000000
F7 Fe F12 F4 F5 Fl
V1-. 000 0 0 000 0
F8 Fe FlO Fll F2 F13 FH

A10
(REF)

81

-
00G0005
B1 (REF) T4 C1 (REF) L2 82 T2 T1
(REF)

Figure 6-1. 816R-2C FM Transmitter (Sheet 1 of 2)

Change 5 6-3
PARTS LISTS 816R-2C

DC1
(REF)
FAN BLADE PIN- 009 -3118 -030

\\\\ A13 A9 ~
A7

\\
\ / /
B2
\ / /

V
/
"'"
L ~O ~O
c:l
/
Z1 C~
""'-

\-
0 c<

<::
n )

Z1 ~
'" \
_0 ~O ~O /
/

~~'" ~~/I
""'-

Z1 A"--..
~ ~~ I

1Mr~ f~~
r----. v I

0 I I II
[7'"

0 0

~
I
A1 c==J !

""'-" § ~c:J
Ii
4[
I

~ ~
po
po
po
~~ 0
ti.

~~)'~
~ T3

~llllllllllllllllill.lllll
00 00
.---'),.,,.-

~
00 00
00 00
00
oc
00
oc
rt~~ 84
Q.2 Q.2 .....-~

I~/ ~
83
/~~ ~ ---
0 0
v....-

rnln n [IE ~~~ B1


~
lorn
D
I
G: \
I -.. ....... I ~ v/
/

~/v
/'
~
h\~--~
===-- ~
~

~
\
\
\ .l-an-J ~ 1\
1\ L
~~~~~ ---::;;
-.. \
---::;;
_"'-. ~ I
~
I
\
\
\ '\ ""-

\
\

\
'\

\ '" ~ ~
r--

\ \ \
T1 T2 85 "" L1 ""C1 95G0253

(REF)

Figure 6-1. 816R-2C FM Transmitter (Sheet 2 of 2)

6-4 Change 5
816R-2C PARTS LISTS

PL180295-2 TRANSMITTER, 816R-2C, 21.5KW FM Rev.M

Ref. Des. Part No. Description

Al *189638-1 CONTROL PANEL


A2 *180299-2 CARD CAGE ASY
A3 *180302-2 IPA ASSY
A4 NOT-USED
A5 *180317-3 COMPONENT SHELF ASSY
A6 *180303-1 CIRCUIT BREAKER ASSY
A7 *786-3451-003 ASSEMBLY, LOW PASS FILTER
A8 *180320-1 COMPONENT PANEL ASSY
A9 *180304-1 SCRASSY
A10 *180318-1 POWER SUPPLY ASSY
All NOT-USED
A12 *786-3335-005 POWER AMPLIFIER CAVITY ASSEMBLY
A13 *180394-1 BLEEDER RESISTOR ASSY
B1 009-0167-010 FAN, CENTRIFUGAL: 800CFM@4"SP, 220/440V, 50/60HZ, IHP 3PH, 3450RPM
MOTOR, DIRECT DRIVE
B2 230-0593-010 MOTOR, ALTERNATING CURRENT: 1/4HP, 1725RPM, 230/460V 60HZ, 3PH,
NEMA FRAME 48, SEALED BALL BEARINGS, OPEN
C1 930-0781-040 CAPACITOR, FIXED, PAPER: 20 UF, ±10%, 10K WVDC OIL FILLED, 1/2-13
TERMINALS
C2 *159422-1 CAP, BLOCKING
DCI 277-5052-010 COUPLER, DIRECTIONAL: W/CRYSTAL DETECTORS&RF MONITOR PORT,
lKWT035KW, 1: 05: 1 VSWRMAX
L1 668-0199-010 REACTOR: 4 HENRIES MIN @ 4.00 ADC, 400 VRMS RIPPLE 300-360 HZ
L2 668-0200-030 REACTOR: 1.0 HENRIES MIN.@ 6.0 ADC, 38VRMS/2500 V, WITHSTANDING, 400
HZ
Sl *627-9743-004 SWITCH ASSEMBLY, SHORTING
S2 *627-9743-004 SWITCH ASSEMBLY, SHORTING
S3 *627-9743-008 SWITC1I ASSEMBLY, SHORTING
S4 *627-9743-008 SWITCH ASSEMBLY, SHORTING
S5 *627-9743-008 SWITCH ASSEMBLY, SHORTING
T1 664-0124-030 TRANSFORMER, POWER: STEP-UP, 200-250 V/8000 VDC
T2 664-5003-010 TRANSFORMER, POWER: STEP-UP, 250 V/800 VDC
T3 662-6024-010 TRANSFORMER, POWER: STEP-DOWN, 250 VOLT/45 VOLT, 3 PH
T4 662-6270-010 TRANSFORMER, POWER: STEP-DN, PRI=230/460V, 50/60HZ, IPH SEC=115V,
2.17AMP, 250VA, OPEN, DRY TYPE CONTROL XFMR
VI 256-0157-000 ELECTRON TUBE: POWERTETRODE
ZlA 353-6596-030 RECTIFIER, SEMICONDUCTOR DEVICE: SILICON, HIGH VLTG DOUBLER
ASSY, 16KV PRY, 4AMP EACH LEG
ZlB 353-6596-030 RECTIFIER, SEMICONDUCTOR DEVICE: SILICON, HIGH VLTG DOUBLER
ASSY, 16KV PRY, 4AMP EACH LEG
ZlC 353-6596-030 RECTIFIER, SEMICONDUCTOR DEVICE: SILICON, HIGH VLTG DOUBLER
ASSY, 16KV PRY, 4AMP EACH LEG

Change 5 6-5
PARTS LISTS 816R-2C

(This Page Intentionally Left Blank)

6-6 Change 4
816R-2C PARTS LISTS

PL180328-1 MAIN CABLE Rev.B

Ref. Des. Part No. Description

PI 372-9755-010 CONNECTOR BODY, PLUG, ELECTRlCAL: 60 POSITIONS, 2 ROW, INDENT


LATCHING, 0.100 X 0.100 CENTERS
P2 372-9755-010 CONNECTOR BODY, PLUG, ELECTRlCAL: 60 POSITIONS, 2 ROW, INDENT
LATCHING, 0.100 X 0.100 CENTERS
P3 372-9766-020 CONNECTOR BODY, PLUG, ELECTRICAL: 20 POSITIONS, PLZD 1 ROW
CONTACT HOUSING, 0.1 "CENTERS, WIDETENT LATCH
P4 372-9766-020 CONNECTOR BODY, PLUG, ELECTRlCAL: 20 POSITIONS, PLZD 1 ROW
CONTACT HOUSING, O. 1"CENTERS, WIDETENT LATCH
P5 372-9761-030 CONNECTOR BODY, PLUG, ELECTRlCAL: 40 CAVITY, 2 ROW DETENT
LATCHING, WIO STRAIN RELIEF, .1"X.l"CENTERS
P6 372-9761-030 CONNECTOR BODY, PLUG, ELECTRlCAL: 40 CAVITY, 2 ROW DETENT
I
LATCHING, WIO STRAIN RELIEF, .1 X.l"CENTERS
P7 372-9766-020 CONNECTOR BODY, PLUG, ELECTRlCAL: 20 POSITIONS, PLZD 1 ROW
CONTACT HOUSING, 0.1 "CENTERS, WIDETENT LArrCH

Change 4 6-7
816R-2C
PARTS LISTS

M1, C1 M2, C2 M3, C3 M4,C4

o o

MUlTIMETER PlATE VOLTAGE PlATE CURRENT POWER OUTPUT


,--------------------------------------------------------------------------------------------------------------------------------
o 2BVSUPPlY
o
o
40....,..
PA SCREEN CURRENT
1llD",,"

........
PA GIW CURRENT
~_2_9_..-.rD.ON_=-g~_~
[__
STATUS
_J D D
0- uMrr-Q
REFLUFWD
- POWER-

0- uMrr-()
o PA SCREEN VOLTAGE
DD DO
O"'ecMCM.D

o
1lIllI .....

PABIM
o AlUI1lK 0 MOOOIU'T\JC OI\P'IQIf..... NJUC
°0
"'P'LATECM.D

V8W!'1.<MJ) RAISE LOWER RAISE LOWER

q METER SB.ECT 0 ~NJUC 0 0 TUNING - - lOAOWG - • 0


: DD D :
lJllEtol\DOOftNTUC Il&loTENTUC -

~
°~ (0
0 CJIl!MOOO!\1I1lJ( 0 r1IILAIftNTUC ST.RESETC:S
. .~~.~
. . . . .......- :
.------------------------------------------------------------------------------------------.------------------------------------_.,.:
:: UP
O~~

9380318

A1

Figure 6-2. Control Panel, At

Change 4
6-8
816R-2C PARTS LISTS

PL189638-1 CONTROL PANEL Rev. -

Ref. Des. Part No. Description

Al * 189668-1 CCA, CONTROL PANEL


C1 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PicaF, ±5%, 500 WVDC
C2 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PicaF, ±5%, 500 WVDC
C3 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PicaF, ±50/0, 500 WVDC
C4 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PicaF, ±5%, 500 WVDC
M1 458-5005-060 METER, ARBITRARY SCALE: 1MADC SENS, 0-8/0-4 SCALES 100 OHM INT RES,
3-1/2" RECT, PANEL MT, PVT AND JWL
M2 458-5005-070 VOLTMETER: DC, 2MADC SENS, 0-10 DC KILOVOLTS SCALE 1000 OHM IN
RES, 3-1/2" RECT, PANEL MT, PVT AND JWL
M3 458-5005-050 AMMETER: DC, 1MADC SENS, 0-5 DC AMPERES SCALE 1250 OHM !NT RES,
3-1/2" RECT, PANEL MT, PVT AND JWL
M4 458-5005-100 METER, SPECIAL SCALE: DC, 100UADC SENS, 0-120%/0-120/0 SCALE, 1750
OHM INT RES, 3-1/2"RECT, PANEL MT, PVT AND JWL

Change 4 6-9
PARTS LISTS 816R-2C

0 0
C J OS1
[C][C]
S1 S2 S3
DJ DJ
S4 S5 S6 S7 S8
8S9
C J OS2 0
OS26 OS27 OS28 OS29
C J OS3
CJ

C J OS4

C J OS5
o CJOS6

CJDS7
C J OS11

C J OS12
C J OS17

C J OS18
C J OS23

C J OS24 ODJ [J DJ
CJOS8 C J OS13 C J OS19 CJ OS25 S10 S11 S12 S13

CJOS9 C J OS14 CJ OS20

0 S14
BS15
DS10 C J OS15

C J OS16
C J OS21

CJ OS22 B
S16 0
FRONT VIEW

C5 R57
R48
R47
R8 R45
R7 R46

R9

~~ fu~ ~~ b :: 0
R39
~
-c=J-
-e::=:r R30
a -e::=:r R31
R24

R25
-c=:J-
-c=J- R20 -c:=J-

8888
(J)

o 0 -e::=:r R32 R26 -c:::=J- R21 -c=J-


~ $~ ~ -u- -e=J- R33
R27 -c:::=J- R22 -c=J-
n rP-n n -e::=:r CR5 R34 R28 -c:::=J- R23 -c=J-

~ -e::=:r R35 R29 -c=J-


VR3

REAR VIEW 95G0180

Figure 6-3.. Control Panel Circuit Card Assembly, AlAI

6-10 Change 4
816R-2C PARTS LISTS

PL189668-1 CCA, CONTROL PANEL Rev.D

Ref. Des. Part No. Description

C1 183-5018-070 CAPACITOR, FIXED, ELECTROLYTIC: 1 MicroF, ±10%, 35 WVDC DIPPED


TANTALUM
C2 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C3 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C4 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C5 183-5018-070 CAPACITOR, FIXED, ELECTROLYTIC: 1 MicroF, ±10%, 35 WVDC DIPPED
TANTALUM
C6 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C7 913-7016-510 CAPACITOR, FIXED, CERAMIC: 10,000 PicaF, ±5%, 50 WVDC
C8 184-9612-010 CAPACITOR, FIXED, ELECTROLYTIC: 100 MicroF, ±10%, 6.3 WVDC
C9 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C10 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10o~, 50 WVDC
C11 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C12 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 MicroF, ±10%, 35 WVDC DIPPED
TANTALUM
C13 CK05BXI04K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C14 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
CIS 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 MicroF, ±lO%, 35 WVDC DIPPED
TANTALUM
C16 M39014/01-1237 CAPACITOR, FIXED, CERAMIC: 1000 PicaF, ±10%, 200 WVDC FR=1.0%/1000 HR
C17 M39014/01-1237 CAPACITOR, FIXED, CERAMIC: 1000 PicaF, ±10%, 200 WVDC FR=1.0%/1000 HR
C18 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 MicroF, ±10%, 35 \VVDC DIPPED
TANTALUM
C19 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 MicroF, ±10%, 35 WVDC DIPPED
TANTALUM
C20 CK05BXI04K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C21 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C22 933-1059-050 CAPACITOR, FIXED, FILM: 1.0 MicroF, ±10%, 200 WVDC
C23 933-1059-050 CAPACITOR, FIXED, FILM: 1.0 MicroF, ±10%, 200 WVDC
C24 933-1059-050 CAPACITOR, FIXED, FILM: 1.0 MicroF, ±10%, 200 WVDC
C25 933-1059-050 CAPACITOR, FIXED, FILM: 1.0 MicroF, ±10%, 200 WVDC
C26 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C27 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C28 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C29 183-5017-070 CAPACITOR, FIXED, ELECTROLYTIC: 10 MicroF, ±10%, 25 WVDC DIPPED
TANTALUM
C30 183-5017-070 CAPACITOR, FIXED, ELECTROLYTIC: 10 MicroF, ±10%, 25 WVDC DIPPED
TANTALUM
C31 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C32 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C33 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C34 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C35 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
CR1 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PlY, 300M.A FAST
RECOVERY, DO-35 PKG (TYPE IN4148)
CR2 353-3644-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 150MA, 75V PIV 500
MILLIWATTS, AXIAL LEADS, DO-35 PKG (lN4454-1)
CR3 353-3644-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 150MA, 75V PIV 500
MILLIWATTS, AXIAL LEADS, DO-35 PKG (lN4454-1)

Change 4 6-11
PARTS LISTS 816R-2C

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

CR4 353-3644-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 150MA, 75V PIV


500MILLIWATTS, AXIAL LEADS, DO-35 PKG (lN4454-l)
CR5 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, lOOOV PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR6 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, lOOOV PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
CR7 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR8 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
CR9 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
DS1 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 X.25"LIGHTED AREA, 4.5MCD
I

INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE


DS2 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS3 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS4 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS5 419-0089~010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS6 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS7 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS8 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS9 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 X.25"LIGHTED AREA, 4.5MCD
I

INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE


DS10 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 X.25"LIGHTED AREA, 4.5MCD
I

INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE


DS11 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS12 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS13 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS14 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS15 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS16 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 X.25"LIGHTED AREA, 4.5MCD
I

INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE


DS17 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 X.25"LIGHTED AREA, 4.5MCD
I

INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE


DS18 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS19 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE

6-12 Change 4
816R-2C PARTS LISTS

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

DS20 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD


INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS21 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS22 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5 "X.25 "LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS23 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS24 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS25 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS26 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS27 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS28 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS29 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
Jl 372-9754-040 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 40 PINS 2 ROW,
STRAIGHT, O.IOO"CTRS, SHROUDED, 0.066"END DIM
J2 372-9754-040 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 40 PINS 2 ROW,
STRAIGHT, O.IOO"CTRS, SHROUDED, 0.066"END DIM
J3 372-9754-040 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 40 PINS 2 ROW,
STRAIGHT, 0.1 OO"CTRS, SHROUDED, 0.066"END DIM
J4 372-9754-040 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 40 PINS 2 ROW,
STRAIGHT, 0.100"CTRS, SHROUDED, 0.066"END DIM
R1 724-5052-780 RESISTOR, FIXED, FILM: 82.5KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R2 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R3 724-5052-410 RESISTOR, FIXED, FILM: I2100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R4 724-5052-410 RESISTOR, FIXED, FILM: 12100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R5 724-5052-410 RESISTOR, FIXED, FILM: 12100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R6 724-5052-410 RESISTOR, FIXED, FILM: 12 1OOHM, ±loAJ, 1/4\VATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R7 724-5052-780 RESISTOR, FIXED, FILM: 82.5KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R8 724-5052-775 RESISTOR, FIXED, FILM: 75KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R9 724-5052-400 RESISTOR, FIXED, FILM: lOOOOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RIO 724-5052-740 RESISTOR, FIXED, FILM: 47.5KOHM, ±I%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RII 724-5052-285 RESISTOR, FIXED, FILM: 4750HM, ±15, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED

Change 4 6-13
PARTS LISTS 816R-2C

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

R12 724-5052-285 RESISTOR, FIXED, FILM: 4750HM, ±15, I/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R13 724-5052-520 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R14 724-5052-520 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/4WATT@70CMETAL FILM,
TC=IOOPPMIDEGC, COLOR BANDED
RI5 724-5052-660 RESISTOR, FIXED, FILM: 20K OHM, ±10/0, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R16 724-5052-660 RESISTOR, FIXED, FILM: 20K OHM, ±1 0/0, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R17 724-5052-050 RESISTOR, FIXED, FILM: 22.10HM, ±1%, I/4WATT@70C METAL FILM,
TC=IOOPPM/DEGC, COLOR BANDED
RI8 724-5052-050 RESISTOR, FIXED, FILM: 22.10HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R19 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPMlDEGC, COLOR BANDED
R20 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R21 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R22 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R23 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±50/0, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R24 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R25 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R26 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R27 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R28 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C ~1ETAL FILM,
TC=250PPMlDEGC, COLOR BANDED
R29 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R30 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±50/o, 2 WATT @ 70C METAL FILM,
TC=250PPMlDEGC, COLOR BANDED
R31 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R32 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R33 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R34 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R35 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R36 747-5491-000 RESISTOR, FIXED, WIRE WOUND: 33 OHMS, ±50/0, 6.5 WATT

6-14 Change 4
816R-2C PARTS LISTS

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

R37 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R38 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R39 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R40 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R41 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R42 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R43 724-5055-380 RESISTOR, FIXED, FILM: 1200 OHM, ±50/0, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R44 724-5052-225 RESISTOR, FIXED, FILM: 1500HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R45 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R46 382-1405-080 RESISTOR, VARIABLE, NONWIRE WOUND: 20K OHMS, ±100/0 1/2 WATT,
CERMET
R47 724-5052-545 RESISTOR, FIXED, FILM: 68100HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R48 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R49 NOT-USED
R50 NOT-USED
R51 382-1405-080 RESISTOR, VARIABLE, NONWIRE WOUND: 20K OHMS, ±100/0 1/2 WATT,
CERMET
R52 RCR07G125JS RESISTOR, FIXED, COMPOSITION: 1.2M OHM, ±50/0, 1/4 WATT
R53 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R54 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R55 382-1405-070 RESISTOR, VARIABLE, NONWIRE WOUND: 10K OHMS, ± 100/0 1/2 WATT,
CERMET
R56 724-5052-740 RESISTOR, FIXED, FILM: 47.5KOHM, ± 1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R57 724-5052-800 RESISTOR, FIXED, FILM: 100KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R58 724-5052-200 RESISTOR, FIXED, FILM: 1000HM, ±l%, 1/4WATT@70CMETALFILM,
TC=100PPM/DEGC, COLOR BANDED
SI 266-9981-020 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
S2 266-9981-020 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
S3 266-9981-030 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, GREEN LED, GREEN LENS/CAP, PC MOUNT
S4 266-9981-010 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, RED LED, RED LENS/CAP, PC MOUNT

Change 4 6-15
PARTS LISTS 816R-2C

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

S5 266-9981-030 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT


ILLUMINATED, GREEN LED, GREEN LENS/CAP, PC MOUNT
S6 266-9981-010 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, RED LED, RED LENS/CAP, PC MOUNT
S7 266-9981-020 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
88 266-9981-020 SWITCH, PUSH: SPDT, ON-MOM ON, 5AMP, 125/250\TAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT'
S9 266-9952-070 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, W/GRN LEDS 60 VDC,
10 MADC MAX, GOLD PLATED CONTACTS
S10 266-9981-040 SWITCH, PUSH: DPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
S11 266-9981-040 SWITCH, PUSH: DPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
S12 266-9981-040 SWITCH, PUSH: DPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
813 266-9981-040 SWITCH, PUSH: DPDT, ON-MOM ON, 5AMP, 125/250VAC CONTACT
ILLUMINATED, YELLOW LED, YELLOW LENS/CAP, PC MOUNT
814 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
S15 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
816 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
TB1 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG
Ul 351-4864-010 MICROCIRCUIT, LINEAR: TRANSISTOR ARRAY, HIGH VOLTAGE, HIGH CUR,
DARLINGTON PAIRS, 7 CKT, 16 PIN PLASTIC DIP
U2 351-5298-010 MICROCIRCUIT, LINEAR: QUAD SPDT JFET ANALOG SWITCH NORMALLY
OPEN, 16 PIN DIP
U3 351-5298-010 MICROCIRCUIT, LINEAR: QUAD SPDT JFET ANALOG SWITCH NORMALLY
OPEN, 16 PIN DIP
U4 351-5305-010 MICROCIRCUIT, DIGITAL: LOW POWER SCHOTTKY, DIVIDE BY 12
COUNTER, 14 PIN DIP, PLASTIC PACKAGE
U5 351-4706-010 MICROCIRCUIT, LINEAR: DUAL TIMER, +16 ·V, 600 MW
U6 736-7026-040 RESISTOR NETWORK: 8 RESISTORS, 47 OHM, ±2% 1/4 WATT/RESISTOR, 16
PIN DIP PACKAGE, 2.4 WATT/PKG
1)7 351-4750-010 MICROCIRCUIT, DIGITAL: DECODER, 3 LINE TO 8 LINE, TTL, LOW POWER
SCHOTTKY, 16 PIN PLASTIC DIP PKG
U8 351-7630-010 MICROCIRCUIT, DIGITAL: LOGIC GATE
U9 351-9005-020 MICROCIRCUIT, DIGITAL: TTL/MSI, 4 BIT BINARY UP/DOWN COUNTER,
DUAL CLOCK W/CLEAR, 16 PIN PLASTIC DIP PKG
UI0 351-1728-020 MICROCIRCUIT, DIGITAL: LSTTL, QUAD 2-INPUTNAND GATE SCHMITT
TRIGGER INPUT, 14 PIN PLASTIC DIP PKG
Ul1 351-4768-010 MICROCIRCUIT, LINEAR: QUAD OP AMP, DIFF INPUTS 14 PIN PLASTIC DIP
PKG, 0-70DEG C
U12 351-5367-010 MICROCIRCUIT, LINEAR: CMOS, VOLTAGE CONVERTER, +5VDC TO +/-5VDC,
8 PIN PLASTIC DIP PKG, 0-70C
VRI 353-6481-11 0 SEMICONDUCTOR DEVICE, DIODE: ZENER, 5.1V, ±5%, 1WATT AXIAL LEADS,
MOLDED BODY

6-16 Change 4
816R-2C PARTS LISTS

PL189668-1 CCA, CONTROL PANEL - Continued Rev.D

Ref. Des. Part No. Description

VR2 353-6481-130 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 5.6 VOLT


VR3 351-1120-010 MICROCIRCUIT, LINEAR: +5 V @ 1 A VOLTAGE REGULATOR TO-220
PLASTIC PACKAGE
XUl 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE'PIN SPACING
XU2 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU3 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU4 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU5 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU6 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU7 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU8 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU9 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XUI0 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XUII 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU12 220-6017-020 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 8 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING

Change 4 6-17
PARTS LISTS 816R-2C

T3 E3 T2 T1 A8

A9 E1
E2

o
T4

IIIII

A7 CR1

M1 M2

~ ~
~
o FIL

0
OA-B
o B-C
D D D
METER LOCAL REMOT
~ 0
OC-A
SELECT

AC VOLTMETER FILAMENT Hou:::J

I tI LJ J LI J lnJ lnJ LJ J LJ ~ IJ J

// 52

o
~l
0
M hl Irl
/ / / / /

A1
/ / A2 A3 A4
II A5 A6
93G0319

Figure 6-4. Card Cage, A2.

6-18 Change 4
816R-2C PARTS LISTS

PL180299-2 CARD CAGE ASSEMBLY Rev.F

Ref. Des. Part No. Description

Al 270-3253-010 CIRCUIT CARD ASSEMBLY: GATING, 3 PHASE, FULL WAVE HARD FIRING,
PLUG IN, USING AMP 534204-1 CONNECTOR
A2 270-3253-010 CIRCUIT CARD ASSEMBLY: GATING, 3 PHASE, FULL WAVE HARD FIRING,
PLUG IN, USING AMP 534204-1 CONNECTOR
A3 270-3253-010 CIRCUIT CARD ASSEMBLY: GATING,3 PHASE, FULL WAVE HARD FIRING,
PLUG IN, USING AMP 534204-1 CONNECTOR
A4 *182901-1 CCA, FILAMENT REGULATOR
A5 *180166-1 CCA, OVERLOAD/RECYCLE
A6 *180161-1 CCA, POWER MONITOR/CONTROL
A7 *189620-1 CCA, CARD CAGE COMPONENT
A8 *180194-1 CCA, BACKPLANE
A9 *172715-1 POWER CONTROL ASSEMBLY
CR1 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRV DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
E1 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E2 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E3 306-2230-000 TERMINAL BOARD: 3 TERMINAL, SOLDER LUG, SNGL MTG FOOT PHENOLIC
BASE
E4 306-0234-000 POST, ELECTRICALIMECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E5 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E6 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
Ml 458-5006-020 AMMETER, AC: 10 MA, SENS, 0-9,0-300 SCALES VOLTS AC, 3-1/2"
RECTANGLE, PIVOT & JEWEL MOVEMENT, IRON VANE
M2 458-5007-010 METER, TIME TOTALIZING: 99999.9 HR, 0.1 HR, INCREMENTS 230 VOLT, 60
HZ, 3-1/2" RECT BEZEL, NO RESET
RVI 714-3258-250 RESISTOR, VOLTAGE DEPENDENT: 2000 AMPS, 0.6 WATT 500 PF, METAL
OXIDE VARISTOR
SI 266-8000-000 SWITCH ASSEMBLY, INTERLOCK: SPDT, 5 AMP @ 28 VDC, PULL TO
MAINTAIN CONNECTION
T1 270-0313-020 TRANSFORMER, POWER: STEP-DOWN, PRI=230/460V, 50/60HZ IPH,
SEC#I=24VCT@40MA, SEC#2&3=18V@400MA, OPEN, DRY
T2 270-0313-020 TRANSFORMER, POWER: STEP-DOWN, PRI=230/460V, 50/60HZ IPH,
SEC#1=24VCT@40MA, SEC#2&3=18V@400MA, OPEN, DRY
T3 270-0313-020 TRANSFORMER, POWER: STEP-DOWN, PRI=230/460V, 50/60HZ 1PH,
SEC#1=24VCT@40MA, SEC#2&3=18V@400MA, OPEN, DRY
T4 662-0898-010 TRANSFORMER, POWER: STEP-DOWN, 166 VRMS/24-56 VRMS

Change 4 6-19
PARTS LISTS 816R-2C

o ~S5 ~ ~ [@ r)~S~
~ ~8 ~ ~@]~
8
IL.---------,'l(J QL]
U4, XU4
~~
fOl

I R34 U8, XU8

R33 1L----_
U3
----IS rsu
, X_U3 rnJ ~
LBiiJ
U2,XU2 ~ rn ~ :~~: :
I. 'I [ill] V ~~
l""-----U1'
X----'U1 S U?, XU?

L3 [~
RV4 =:::>
-=:::>
C:-RV-3

P1

93G0320

Figure 6-5Q Filament Regulator Circuit Card Assembly, A2A4Q

6-20 Change 4
816R-2C PARTS LISTS

PL182901-1 CCA, FILAMENT REGULATOR Rev.E

Ref. Des. Part No. Description

C1 NOT-USED
C2 NOT-USED
C3 NOT-USED
C4 184-9102-110 CAPACITOR,FIXED,ELECTROLYTIC:220 UF,+-200/0, 10 WVDC DIPPED
TANTALUM
C5 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-100/0,50 WVDC
C6 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-100/0,50 WVDC
C7 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-100/0,50 WVDC
C8 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-10%,50 WVDC
C9 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-100/0,50 WVDC
C10 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-l 00/0,50 WVDC
C11 CM05FD101J03 CAPACITOR,FIXED,MICA: 100 PF,+-5%,500 WVDC
C12 CM05FD101J03 CAPACITOR,FIXED,MICA:100 PF,+-50/0,500 WVDC
C13 CM05FD101J03 CAPACITOR,FIXED,MICA: 100 PF,+-50/0,500 WVDC
C14 CM05FD101J03 CAPACITOR,FIXED,MICA:100 PF,+-50/0,500 WVDC
C15 913-3279-270 CAPACITOR,FIXED,CERAMIC:l UF,+-20%,50 WVDC
C16 183-5016-070 CAPACITOR,FIXED,ELECTROLYTIC:33 UF.,+-100/0,20 WVDC DIPPED
TANTALUM
C17 184-9102-370 CAPACITOR,FIXED,ELECTROLYTIC:2.2 UF,+-200/0,35 WVDC DIPPED
TANTALUM
C18 184-9102-370 CAPACITOR,FIXED,ELECTROLYTIC:2.2 UF,+-20%,35 WVDC DIPPED
TANTALUM
C19 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-100/0,50 WVDC
C20 CK05BXI04K CAPACITOR,FIXED,CERAMIC:O.l UF,+-l 00/0,50 WVDC
C21 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-100/0,50 WVDC
C22 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-lO%,50 WVDC
C23 CK05BX104K CAPACITOR,FIXED,CERAMIC:O.l UF,+-l 00/0,50 WVDC
C24 183-5031-030 CAPACITOR,FIXED,ELECTROLYTIC:100 UF,+-200/0,63 WVDC WITH
INSULATING SLEEVE
C25 NOT-USED
C26 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-l 00/0,50 WVDC
C27 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-100/0,50 WVDC
C28 184-9102-200 CAPACITOR,FIXED,ELECTROLYTIC:IOO UF,+-20%,20 WVDC DIPPED
TANTALUM
C29 CK05BX104K CAPACITOR,FIXED,CERAMIC:0.1 UF,+-100/0,50 WVDC
C30 184-9102-100 CAPACITOR,FIXED,ELECTROLYTIC:IOO UF,+-20%,10 WVDC DIPPED
TANTALUM
C31 CM05FD101J03 CAPACITOR,FIXED,MICA:IOO PF,+-5%,500 WVDC
C32 CM05FDI01J03 CAPACITOR,FIXED,MICA: 100 PF,+-50/0,500 WVDC
CRI 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON, lAMP, 1OOOV PRY DO-41 EPOXY
PKG,AXIAL LEADS (lN4007)
CR2 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON, lAMP, 1OOOV PRY DO-41 EPOXY
PKG,AXIAL LEADS (lN4007)
DS1 419-0095-020 LIGHT EMITTING DIODE:YELLOW DIFFUSED,BLOCK FORM RT
ANGLE,WITHOUT RESISTOR,3 VDC MAX,30 MA
DS2 419-0095-030 LIGHT EMITTING DIODE:RED DIFFUSED,BLOCK FORM RT ANGLE,WITHOUT
RESISTOR,2 VDC MAX,50 MA
DS3 419-0095-030 LIGHT EMITTING DIODE:RED DIFFUSED,BLOCK FORM RT ANGLE,WITHOUT
RESISTOR,2 VDC MAX,50 MA

Change 5 6-21
PARTS LISTS 816R-2C

PL182901-1 CCA, FILAMENT REGULATOR - Continued Rev.E

Ref. Des. Part No. Description

DS4 419-0095-010 LIGHT EMITTING DIODE:GREEN DIFFUSED,BLOCK FORM RT


ANGLE,WITHOUT RESISTOR,3 VDC MAX,60 MA
DS5 419-0095-020 LIGI-IT EMITTING DIODE:YELLOW DIFFUSED,BLOCK FORM RT
ANGLE,WITHOUT RESISTOR,3 VDC MAX,30 MA
K1 410-6009-010 RELAY,SOLID STATE:VOLTAGE 20-140 VAC,1.0 AMP LOAD CURRENT AT 40
DEG C,3.5 VDC ACTUATING
K2 410-6009-010 RELAY,SOLID STATE:VOLTAGE 20-140 VAC,1.0 AMP LOAD CURRENT AT 40
DEG C,3.5 VDC ACTUATING
K3 410-6009-010 RELAY,SOLID STATE:VOLTAGE 20-140 VAC,1.0 AMP LOAD CURRENT AT 40
DEG C,3.5 VDC ACTUATING
L1 MS91189-21 COIL,RADIO FREQUENCY:4.7 UH,+-100/0,860 DCMA,Q=60MIN 90 MHZ SELF
RESONANT FREQ,0.560 DCR MAX
L2 MS91189-21 COIL,RADIO FREQUENCY:4.7 UH,+-100/0,860 DCMA,Q=60MIN 90 MHZ SELF
RESONANT FREQ,0.560 DCR MAX
L3 MS91189-21 COIL,RADIO FREQUENCY:4.7 UH,+-100/0,860 DCMA,Q=60MIN 90 MHZ SELF
RESONANT FREQ,0.560 DCR MAX
L4 MS91189-21 COIL,RADIO FREQUENCY:4.7 UH,+-10%,860 DCMA,Q=60MIN 90 MHZ SELF
RESONANT FREQ,0.560 DCR MAX
PI 372-9739-010 CONNECTOR,RECEPTACLE,ELECTRICAL:2 ROW CLOSED ENTRY BOARD
MTD,50 POSN,0.100"CTR,W/BD RETENTION POSTS
Rl 724-5053-440 RESICTOR,FIXED,FILM:221 OOHM,+-l 0/0, 1/2WATT@70C METAL
FILM,TC=1 OOPPMIDEGC,COLOR BANDED
R2 382-1405-210 RESISTOR,VARIABLE,NONWIRE WOUND:5000 OHMS,+-l 00/0 1/2
WATT,CERMET
R3 724-5054-310 RESISTOR,FIXED,FILM:330 OHM,+-50/0,1 WATT @ 70C METAL
FILM,TC=250PPMIDEGC,COLOR BANDED
R4 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1 0/0, 1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R5 724-5052-400 RESISTOR,FIXED,FILM:10000HM,+-10/0,1/4WATT@70C METAL
FILM,TC=l OOPPMIDEGC,COLOR BANDED
R6 724-5052-520 RESISTOR,FIXED,FILM:47500HM,+-10/0,1/4WATT@70C METAL
FILM,TC=1OOPPMIDEGC,COLOR BANDED
R7 382-1405-250 RESISTOR,VARIABLE,NONWIRE WOUND:50K OHMS,+-100/0 1/2 WATT,CERMET
R8 724-5052-400 RESISTOR,FIXED,FILM:10000HM,+-I%,1/4WATT@70C METAL
FILM,TC=l OOPPMlDEGC,COLOR BANDED
R9 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-10/0,1/4WATT@70C METAL
FILM,TC=1OOPPMlDEGC,COLOR BANDED
RIO 724-5052-275 RESISTOR,FIXED,FILM:3920HM,+-1%,1/4WATT@70C METAL
FILM,TC=l OOPPMIDEGC,COLOR BANDED
R11 724-5052-275 RESISTOR,FIXED,FILM:3920HM,+-10/0,1/4WATT@70C METAL
FILM,TC=100PPMIDEGC,COLOR BANDED
R12 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1 0/0,1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R13 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1 0/0, 1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R14 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1%,1/4WATT@70C METAL
FILM,TC=1OOPPMIDEGC, COLOR BANDED
R15 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1 %, 1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED

6-22 Change 5
816R-2C PARTS LISTS

PL182901-1 CCA, FILAMENT REGULATOR - Continued Rev.E

Ref. Des. Part No. Description

R16 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-10/0,1/4WATT@70C METAL


FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R17 724-5052-665 RESISTOR,FIXED,FILM:22.1KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC=1 OOPPMIDEGC,COLOR BANDED
R18 724-5052-660 RESISTOR,FIXED,FILM:20K OHM,+-1 0/0, 1/4 WATT @ 70C METAL
FILM,TC= 1OOPPM/DEGC,COLOR BANDED
R19 724-5052-600 RESISTOR,FIXED,FILM:10KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R20 382-1405-250 RESISTOR,VARIABLE,NONWIRE WOUND:50K OHMS,+-1 00/0 1/2 WATT,CERMET
R21 724-5052-200 RESISTOR,FIXED,FILM: 1OOOHM,+-l 0/0, 1/4WATT@70C METAL
FILM,TC=1 OOPPMIDEGC,COLOR BANDED
R22 724-5052-200 RESISTOR,FIXED,FILM:1000HM,+-10/0,1/4WATT@70C METAL
FILM,TC=1 OOPPMIDEGC,COLOR BANDED
R23 724-5052-600 RESISTOR,FIXED,FILM:10KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC= 1OOPPM/DEGC,COLOR BANDED
R24 724-5052-600 RESISTOR,FIXED,FILM:I0KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R25 724-5052-600 RESISTOR,FIXED,FILM:10KOHM,+-1%,1/4WATT@70C METAL
FILM,TC= 1OOPPMIDEGC,COLOR BANDED
R26 724-5052-600 RESISTOR,FIXED,FILM:10KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC=l OOPPMIDEGC,COLOR BANDED
R27 724-5052-600 RESISTOR,FIXED,FILM:10KOHM,+-10/0,1/4WATT@70C METAL
FILM,TC= 1OOPPM/DEGC,COLOR BANDED
R28 RLR07C2204GS RESISTOR,FIXED,FILM:2.2M OHM,+-20/0, 114 WATT FR=.OO 10/0/1 OOOHR
R29 RLR07C2204GS RESISTOR,FIXED,FILM:2.2M OHM,+-20/0, 1/4 WATT FR=.OO 10/0/1 OOOHR
R30 724-5052-400 RESISTOR,FIXED,FILM:10000HM,+-10/0,1/4WATT@70C METAL
FILM,TC= 1OOPPMlDEGC,COLOR BANDED
R31 724-5052-400 RESISTOR,FIXED,FILM:IOOOOHM,+-10/0,1/4WATT@70C METAL
FILM,TC=l OOPPMIDEGC,COLOR BANDED
R32 724-5052-265 RESISTOR,FIXED,FILM:3320HM,+-1 0/0, 1/4 WATT@70C METAL
FILM,TC=l OOPPMIDEGC,COLOR BANDED
R33 724-5055-230 RESISTOR,FIXED,FILM:68 OHM,+-50/0,2 WATT 2 70C METAL
FILM,TC=250PPMIDEGC,COLOR BANDED
R34 724-5054-230 RESISTOR,FIXED,FILM:68 OHM,+-5%,1 WATT @ 70C METAL
FILM,TC=250PPMIDEGC,COLOR BANDED
RVI 714-7015-010 RESISTOR,VOLTAGE SENSITIVE: 1000 AMPS,0.50 WATT 3500 PF,METAL OXIDE
VARISTOR
RV2 714-7008-010 RESISTOR,VOLTAGE SENSITIVE:4000 AMPS,0.85 WATT 1000 PF,METAL OXIDE
VARISTOR
RV3 714-7008-010 RESISTOR,VOLTAGE SENSITIVE:4000 AMPS,0.85 WATT 1000 PF,METAL OXIDE
VARISTOR
RV4 714-7008-010 RESISTOR,VOLTAGE SENSITIVE:4000 AMPS,0.85 WATT 1000 PF,METAL OXIDE
VARISTOR
Sl 266-5415-670 SWITCH,TOGGLE:3PDT,5 AMP @ 28VDC/120 VAC ON-NONE-ON
ACTION,RIGHT ANGLE,PC MOUNT
S2 266-5404-190 SWITCH,PUSH:SPDT-MOM,lAMP,28VDC/120VAC CONT RATING BUTTON
COLOR-NONE,EDGE MT,RT ANGLE PC TERMINATIONS
S3 266-5404-190 SWITCH,PUSH:SPDT-MOM,lAMP,28VDC/120VAC CONT RATING BUTTON
COLOR-NONE,EDGE MT,RT ANGLE PC TERMINATIONS

Change 5 6-23
PARTS LISTS 816R-2C

PL182901-1 CCA, FILAMENT REGULATOR - Continued Rev.E

Ref. Des. Part No. Description

TP1 360-0495~0 1O JACK,TIP:BLACK,NYLON INSULATED,PWB MOUNTING HIGH PROFILE


TP2 360-0495-170 JACK,TIP:BLUE,NYLON INSULATED TIP,PWB MOUNTING LOW PROFILE
TP3 360-0495-030 JACI(,TIP:RED,NYLON INSULATED,PWB MOUNTING HIGH PROFILE
Ul 351-7629-010 MICROCIRCUIT,DIGITAL:QUAD 2 INPUT NAND GATE,TTL, 14 PIN DIP,PLASTIC
PACKAGE
U2 351-7629-010 MICROCIRCUIT,DIGITAL:QUAD 2 INPUT NAND GATE,TTL, 14 PIN DIP,PLASTIC
PACKAGE
U3 351-7629-010 MICROCIRCUIT,DIGITAL:QUAD 2 INPUT NAND GATE,TTL, 14 PIN DIP,PLASTIC
PACKAGE
U4 351-7634-010 MICROCIRCUIT,DIGITAL:TTL,QUAD 2 INPUT AND GATE 14 PIN PLASTIC DIP
PKG
U5 NOT-USED
U6 351-1137-020 MICROCIRCUIT,LINEAR:TIMER,+ 18V,600 MW
U7 351-4714-020 MICROCIRCUIT,LINEAR:30 VOLT,1000 OHMS IMPEDANCE
U8 351-1122-010 MICROCIRCUIT,LINEAR:QUAD COMPARATOR,LOW OFFSET LOW POWER,14
PIN PLASTIC DIP PKG
U9 351-1120-050 MICROCIRCUIT,LINEAR:15V POSITIVE VOLTAGE REGULATOR 1.5AMP,TO-220
PLASTIC PACKAGE
U10 351-1120-010 MICROCIRCUIT,LINEAR:+5 V @ 1 A VOLTAGE REGULATOR TO-220 PLASTIC
PACKAGE
Ul1 351-4801-010 MICROCIRCUIT,LINEAR:PRECISION BCD BUFFERED REFERENCE,TO-5
PACKAGE
XKl 220-6017-040 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XK2 220-6017-040 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XK3 220-6017-040 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU1 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU2 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU3 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU4 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU5 NOT-USED
XU6 220-6017-020 SOCKET,PLUG-IN ELECTRONIC COMPONENT:8 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU7 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING
XU8 220-6017-030 SOCKET,PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,0.3"
WIDE PIN SPACING

6-24 Change 5
816R-2C PARTS LISTS

(This Page Intentionally Left Blank)

Change 4 6-25
PARTS LISTS 816R-2C

o -1 R13 ~
C1
o
D CR1
-1 R14 ~ --rr=J-
OC17 -c=J-- R7 -1 R1 t-
@® DC12 -1 R2 ~
CR10
---D- gQ]D~
C3

~ c=J
~ ~
-1 R16 l- R3

CR7 -cJ}-- 60§


-CEiD-
CR8 --rr=J-
E2
@ E3[[JJE1

-1 R18 t- -c=J-- R9
O OC14
C19 -cJ}--
C23 C20
CR5
o o
~[DD2 s~D~
~
G --GiU-
0) +O~
C6
c=J
--1 R6 ~
~ ~ ~CR6 DC7
CR11 ---rr:=J- CR9 ---rr:=J-
OC24 DC21
G DC8

-1 f- 0+
G ~~
R11

-CR2LJ-
~ ~~
-1 R12
~
---D- VR1

i~ ~ I
I I ---D- CR4
<
:::0 D
N C10

(@
:II..-..- _=
FR_ON_T 1:
93G0321

Figure 6-6., OverloadlRecycle Circuit Card Assembly, A2A5..

6-26 Change 4
816R-2C PARTS LISTS

PL180166-1 CCA,OVERLOADffiECYCLE Rev.G

Ref. Des. Part No. Description

C1 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC


C2 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 100 WVDC
C3 CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 UF, ±10%, 50 WVDC
C4 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C5 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 100 WVDC
C6 CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 UF, ±10%, 50 WVDC
C7 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C8 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C9 184-9102-370 CAPACITOR, FIXED, ELECTROLYTIC: 2.2 UF, ±20%, 35 WVDC DIPPED
TANTALUM
C10 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C11 184-9102-410 CAPACITOR, FIXED, ELECTROLYTIC: 10 UF, ±20%, 35 WVDC DIPPED
TANTALUM
C12 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C13 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 100 WVDC
C14 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C15 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 100 WVDC
C16 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 UF, ±10%, 35 WVDC DIPPED
TANTALUM
C17 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C18 184-9102-410 CAPACITOR, FIXED, ELECTROLYTIC: 10 UF, ±20%, 35 WVDC DIPPED
TANTALUM
C19 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C20 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C21 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
e22 183-5103-050 CAPACITOR, FIXED, ELECTROLYTIC: 330 UF, ±20%, 50 WVDC ALUMINUM,
SINGLE ENDED
C23 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C24 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
CR1 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PIV, 300MA FAST
RECOVERY, DO-35 PKG (TYPE 1N4148)
CR2 353-0293-020 SEMICONDUCTOR DEVICE, ASSEMBLY: LED, YELLOW
CR3 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PIV, 300MA FAST
RECOVERY, DO-35 PKG (TYPE 1N4148)
CR4 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
CR5 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PIV, 300MA FAST
RECOVERY, DO-35 PKG (TYPE 1N4148)
CR6 353-0293-020 SEMICONDUCTOR DEVICE, ASSEMBLY: LED, YELLOW
CR7 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PIV, 300MA FAST
RECOVERY, DO-35 PKG (TYPE 1N4148)
CR8 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PIV, 300MA FAST
RECOVERY, DO-35 PKG (TYPE 1N4148)
CR9 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
CR10 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
CR11 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)

Change 4 6-27
PARTS LISTS 816R-2C

PL180166-1 CCA, OVERLOADfRECYCLE - Continued Rev.G

Ref. Des. Part No. Description

CR12 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (IN4004)
Jl 372-9739-010 C01\TNECTOR, RECEPTACLE, ELECTRICAL: 2 ROW CLOSED ENTRY BOARD
MTD, 50 POSN, 0.100"CTR, W/BD RETENTION POSTS
Kl 410-0572-010 RELAY, REED: SPDT, 0.25AMP, 4 WATT, 100VDC CONTACTRTG 24VDC, 2200
OHM COIL, PC MOUNT, DUAL-IN-LINE PKG
Ll MS75089-11 COIL, RADIO FREQUENCY: 100.0UH, 160MADC, 3.12 OHMS
Ql 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q2 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q3 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q4 353-6468-060 SEMICONDUCTOR DEVICE, THYRISTOR: 1.6AMP, 400V, SCR TO-5 PKG
Q5 353-6468-060 SEMICONDUCTOR DEVICE, THYRISTOR: 1.6AMP, 400V, SCR TO-5 PKG
Q6 352-1104-010 TRANSISTOR: NPN, SILICON, 4AMP, 100V, 1.5 WATT DISS PLASTIC PKG,
CHASSIS MT, (MJE243)
Q7 353-6468-060 SEMICONDUCTOR DEVICE, THYRISTOR: 1.6AMP, 400V, SCR TO-5 PKG
Q8 353-6468-060 SEMICONDUCTOR DEVICE, THYRISTOR: 1.6AMP, 400V, SCR TO-5 PKG
R1 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±l%, 1/4WATT@70CMETALFILM,
TC=100PPM/DEGC, COLOR BANDED
R2 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R3 724-5052-905 RESISTOR, FIXED, FILM: 475KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R4 724-5052-285 RESISTOR, FIXED, FILM: 4750HM, ±15, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R5 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R6 724-5052-905 RESISTOR, FIXED, FILM: 475KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R7 RLR07C2204GS RESISTOR, FIXED, FILM: 2.2M OHM, ±2%, 1/4 WATT FR=.OOI%/lOOOHR
R8 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R9 RLR07C2204GS RESISTOR, FIXED, FILM: 2.2M OHM, ±2%, 1/4 WATT FR=.OOI %/1 OOOHR
RIO 724-5052-905 RESISTOR, FIXED, FILM: 475KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R11 724-5054-420 RESISTOR, FIXED, FILM: 2700 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R12 747-5498-000 RESISTOR, FIXED, WIRE WOUND: 150 OHMS, ±5%, 6.5 WATT
R13 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R14 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R15 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R16 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±lo~, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R17 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±1 %, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R18 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED

6-28 Change 4
816R-2C PARTS LISTS

PL180166-1 CCA, OVERLOADIRECYCLE - Continued Rev.G

Ref. Des. Part No. Description

R19 724-5053-240 RESISTOR, FIXED, FILM: 2210HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R20 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R21 724-5053-010 RESISTOR, FIXED, FILM: 100HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R22 724-5053-600 RESISTOR, FIXED, FILM: 10KOHM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R23 724-5053-600 RESISTOR, FIXED, FILM: 10KOHM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R24 747-5455-000 RESISTOR, FIXED, WIRE WOUND: 560 OHMS, ±5%, 6.5 WATT
R25 724-5053-240 RESISTOR, FIXED, FILM: 2210HM, ±1%, 1/2WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R26 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±l%, 1/2WATT@70C METAL FILM,
TC=lOOPPM/DEG C, COLOR BANDED
R27 724-5053-240 RESISTOR, FIXED, FILM: 2210HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R28 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±l%, l/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
SI 266-5404-190 SWITCH, PUSH: SPDT-MOM, lAMP, 28VDC/120VAC CONT RATING BUTTON
COLOR-NONE, EDGE MT, RT ANGLE PC TERMINATIONS
S2 266-5321-980 SWITCH, TOGGLE: SPD1', ON-NONE-ON, 5 AMP CONTACT RATING
Ul 351-1137-020 MICROCIRCUIT, LINEAR: TIMER, +18V, 600 MW
U2 351-7629-010 MICROCIRCUIT, DIGITAL: QUAD 2 INPUT NAND GATE, TTL, 14 PIN DIP,
PLASTIC PACKAGE
U3 351-1137-020 MICROCIRCUIT, LINEAR: TIMER, + 18V, 600 MW
U4 351-1137-020 MICROCIRCUIT, LINEAR: TIMER, +18V, 600 MW
U5 351-5305-010 MICROCIRCUIT, DIGITAL: LOW POWER SCHOTTKY, DIVIDE BY 12
COUNTER, 14 PIN DIP, PLASTIC PACKAGE
U6 351-1137-020 MICROCIRCUIT, LINEAR: TIMER, +18V, 600 MW
VRI 353-6481-470 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 30 VOLT
VR2 351-1120-010 MICROCIRCUIT, LINEAR: +5 V @ 1 A VOLTAGE REGULATOR TO-220
PLASTIC PACKAGE
XKl 220-0049-010 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 14 POSTS
XUl 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU2 220-0049-010 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 14 POSTS
XU3 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU4 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU5 220-0049-010 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 14 POSTS
XU6 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS

Change 4 6-29
PARTS LISTS 816R-2C

o ®
~DG D
C3

CR1
~ ~~~
~
XU10
~
c==:J
C13 ~

~ XU5
~
~~ ~C4
-e::n- N
~CJet:
XU2

-g-
~
C14
~ c==:J c==:J
~~
C15
tt:J
CAUTION

0~~
SENSI n YE ELECTnNI C
~ DEVICES

~~
0~
o (tc~
)
[E[] ~ CR11
-rr::J- ~
R48

o XK1 Q K1 S~~:;; [[]~ XU3 XU4~


~
C16

o CR2
---CJl-
E3 ITJJ E1
CR8
---CJl-
--rr=J-
~ ~~
~~
c=JC17

O R7
~
E2 CR9

o
IR9l
G)-3-0
~ VR1
J1

C=--.J ~ -C@J- --[]E]- --rr=J-


G -rnD- -1 R37 ~
~
~
CL:Bb- ---cmu-
® ~
~t::\
~ ~Q®~\.J
R22

~ ---CJl- ---CJl- CR10 ---CJl-


CR4
@
o~ --[]3I]-
~
QL]
CR5
C12
+-{§D-
~
~
49

93G0322

Figure 6-7. Power Monitor/Control Circuit Card Assembly, A2A6

6-30 Change 4
816R-2C PARTS LISTS

PL180161-1 CCA, POWER MONITOR/CONTROL Rev.G

Ref. Des. Part No. Description

C1 184-9102-410 CAPACITOR, FIXED, ELECTROLYTIC: 10 MicroF, ±20%, 35 WVDC DIPPED


TANTALUM
C2 CK05BXl04K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C3 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C4 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C5 183-5016-080 CAPACITOR, FIXED, ELECTROLYTIC: 47 MicroF, ±10%, 20 WVDC DIPPED
TANTALUM
C6 913-3813-000 CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, +_20%,50 WVDC
C7 913-3813-000 CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, +_20%,50 WVDC
C8 CK06BXl05K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
C9 CK06BXl05K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
C10 CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
Cl1 183-5111-080 CAPACITOR, FIXED, ELECTROLYTIC: 220 MicroF, ±20%, 35 WVDC
ALUMINUM, RADIAL LEADS
C12 183-5031-080 CAPACITOR, FIXED, ELECTROLYTIC: 100 MicroF, ±20%, 50 WVDC RADIAL
LEADS
C13 CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
C14 CK06BXl05K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
CIS CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
C16 CK06BXl05K CAPACITOR, FIXED, CERAMIC: 1 MicroF, ±10%, 50 WVDC
C17 CK05BXl04K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 50 WVDC
C18 183-5018-110 CAPACITOR, FIXED, ELECTROLYTIC: 4.7 MicroF, ±10%, 35 WVDC DIPPED
TANTALUM
C19 184-9102-410 CAPACITOR, FIXED, ELECTROLYTIC: 10 MicroF, ±20%, 35 WVDC DIPPED
TANTALUM
C20 184-9102-160 CAPACITOR, FIXED, ELECTROLYTIC: 150 MicroF, ±20%, 15 WVDC DIPPED
TANTALUM
C2l 184-9102-200 CAPACITOR, FIXED, ELECTROLYTIC: 100 MicroF, ±20%, 20 WVDC DIPPED
TANTALUM
C22 184-9102-200 CAPACITOR, FIXED, ELECTROLYTIC: 100 MicroF, ±20%, 20 WVDC DIPPED
TANTALUM
CR1 353-3691-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, HOT CARRIER 70V, 250MW,
2PicaF NOM, GLASS PKG, AXIAL LEADS (lN5711)
CR2 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR3 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR4 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR5 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
CR6 353-3691-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, HOT CARRIER 70V, 250MW,
2PicaF NOM, GLASS PKG, AXIAL LEADS (lN571l)
CR7 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (IN4007)
CR8 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR9 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)

Change 4 6-31
PARTS LISTS 816R-2C

PL180161-1 CCA, POWER MONITOR/CONTROL - Continued Rev.G

Ref. Des. Part No. Description

CRIO 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (IN4007)
CR1I 353-3691-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, HOT CARRIER 70V, 250MW,
2PicaF NOM, GLASS PKG, AXIAL LEADS (INS711)
11 372-9739-010 CONNECTOR, RECEPTACLE, ELECTRICAL: 2 ROW CLOSED ENTRY BOARD
MTD, 50 POSN, 0.100"CTR, W/BD RETENTION POSTS
K1 410-0572-010 RELAY, REED: SPDT, 0.25AMP, 4 WATT, 100VDC CONTACT RTG 24VDC, 2200
OHM COIL, PC MOUNT, DUAL-IN-LINE PKG
Q1 352-0613-010 TRANSISTOR: NPN, SILICON, VCEO=40 VDC, IC=0.7 AMP 5 WATT, TO-S
PACKAGE
Q2 352-0613-010 TRANSISTOR: NPN, SILICON, VCEO=40 VDC, IC=0.7 AMP 5 WATT, TO-5
PACKAGE
Q3 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q4 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q5 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-I8 PKG (2N2222A)
R1 382-1405-220 RESISTOR, VARIABLE, NONWlRE WOUND: 10K OHMS, ±10% 1/2 WATT,
CERMET
R2 382-1405-250 RESISTOR, VARIABLE, NONWlRE WOUND: 50K OHMS, ±10% 1/2 WATT,
CERMET
R3 382-1405-230 RESISTOR, VARIABLE, NONWlRE WOUND: 20K OHM, ± 10%, 112 WATT,
CERMET, 25 TURN
R4 382-1405-220 RESISTOR, VARIABLE, NONWlRE WOUND: 10K OHMS, ± 10% 1/2 WATT,
CERMET
R5 382-1405-230 RESISTOR, VARIABLE, NONWlRE WOUND: 20K OHM, ± 10%, 1/2 WATT,
CERMET, 25 TURN
R6 382-1405-220 RESISTOR, VARIABLE, NONWlRE WOUND: 10K OHMS, ±10% 1/2 WATT,
CERMET
R7 382-1405-220 RESISTOR, VARIABLE, NONWlRE WOUND: 10K OHMS, ±10 % 1/2 WATT,
CERMET
R8 382-1405-220 RESISTOR, VARIABLE, NONWlRE WOUND: 10K OHMS, ±10% 1/2 WATT,
CERMET
R9 382-1405-220 RESISTOR, VARIABLE, NONWIRE WOUND: 10K OHMS, ± 10% 1/2 WATT,
CERMET
RIO 382-1405-250 RESISTOR, VARIABLE, NONWIRE WOUND: 50K OHMS, ±10% 1/2 WATT,
CERMET
R11 724-5052-265 RESISTOR, FIXED, FILM: 3320HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R12 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ± 1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R13 724-5052-200 RESISTOR, FIXED, FILM: 1000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R14 724-5052-695 RESISTOR, FIXED, FILM: 30.1KOHM, ± 1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R15 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R16 724-5052-265 RESISTOR, FIXED, FILM: 3320HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R17 724-5052-695 RESISTOR, FIXED, FILM: 30.1KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED

6-32 Change 4
816R-2C PARTS LISTS

PL180161-1 CCA, POWER MONITOR/CONTROL - Continued Rev.G

Ref. Des. Part No. Description

RI8 724-5052-545 RESISTOR, FIXED, FILM: 68100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RI9 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R20 724-5052-400 RESISTOR, FIXED, FILM: lOOOOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R21 724-5053-450 RESISTOR, FIXED, FILM: 27400HM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R22 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±I%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R23 724-5053-450 RESISTOR, FIXED, FILM: 27400HM, ±I%, I/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R24 724-5053-090 RESISTOR, FIXED, FILM: 47.50HM, ±l %, I/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R25 724-5052-995 RESISTOR, FIXED, FILM: IMEGOHM, ±I%, I/4WATT@70CMETALFILM,
TC=100PPM/DEGC, COLOR BANDED
R26 724-5052-840 RESISTOR, FIXED, FILM: 162KOHM, ±l 0/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R27 724-5052-240 RESISTOR, FIXED, FILM: 2000HM, ±10/0, I/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R28 724-5052-695 RESISTOR, FIXED, FILM: 30.IKOHM, ±I%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R29 724-5052-645 RESISTOR, FIXED, FILM: I5KOHM, ±I%, I/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R30 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±I 0/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R3I 724-5052-645 RESISTOR, FIXED, FILM: I5KOHM, ±I%, I/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R32 724-5052-905 RESISTOR, FIXED, FILM: 475KOHM, ±I 0/0, I/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R33 724-5052-545 RESISTOR, FIXED, FILM: 68100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R34 724-5053-090 RESISTOR, FIXED, FILM: 47.50HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R35 724-5053-650 RESISTOR, FIXED, FILM: 22.1KOHM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R36 724-5053-630 RESISTOR, FIXED, FILM: 15KOHM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R37 724-5054-360 RESISTOR, FIXED, FILM: 820 OHM, ±50/0, 1 WATT @70CC METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R38 724-5053-485 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEG C, COLOR BANDED
R39 724-5053-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R40 724-5053-650 RESISTOR, FIXED, FILM: 22. 1KOHM, ±I%, I/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R41 724-5053-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/2WATT@70CMETAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R42 724-5053-630 RESISTOR, FIXED, FILM: I5KOHM, ±10/0, I/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED

Change 4 6-33
PARTS LISTS 816R-2C

PL180161-1 CCA, POWER MONITOR/CONTROL - Continued Rev.G

Ref. Des. Part No. Description

R43 724-5052-240 RESISTOR, FIXED, FILM: 2000HM, ± 10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R44 724-5052-840 RESISTOR, FIXED, FILM: 162KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R45 724-5052-515 RESISTOR, FIXED, FILM: 43200HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R46 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R47 724-5052-660 RESISTOR, FIXED, FILM: 20K OHM, ±1%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R48 724-5052-240 RESISTOR, FIXED, FILM: 2000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R49 724-5052-645 RESISTOR, FIXED, FILM: 15KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R50 724-5052-840 RESISTOR, FIXED, FILM: 162KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R51 724-5052-660 RESISTOR, FIXED, FILM: 20K OHM, ±1%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R52 724-5052-645 RESISTOR, FIXED, FILM: 15KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R53 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R54 724-5054-250 RESISTOR, FIXED, FILM: 100 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R55 724-5053-515 RESISTOR, FIXED, FILM: 82500HM, ± 1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R56 724-5054-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R57 724-5054-330 RESISTOR, FIXED, FILM: 470 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPMlDEGC, COLOR BANDED
SI 266-5404-190 SWITCH, PUSH: SPDT-MOM, lAMP, 28VDC/120VAC CONT RATING BUTTON
COLOR-NONE, EDGE MT, RT ANGLE PC TERMINATIONS
TP1 360-0495-130 JACK, TIP: RED, NYLON INSULATED TIP, PWB MOUNTING LOW PROFILE
TP2 360-0495-140 JACK, TIP: ORANGE, NYLON INSULATED TIP, PWB MOUNTING LOW
PROFILE
TP3 360-0495-150 JACK, TIP: YELLOW, NYLON INSULATED TIP, PWB MOUNTING LOW
PROFILE
TP4 360-0495-120 JACK, TIP: BROWN, NYLON INSULATED TIP, PWB MOUNTING LOW PROFILE
TP5 360-0495-110 JACK, TIP: BLACK, NYLON INSULATED TIP, PWB MOUNTING LOW PROFILE
Ul 351-1110-020 MICROCIRCUIT, LINEAR: OPERATIONAL AMPLIFIER, ±18 VOLTS SUPPLY, 8
LEAD PLASTIC DUAL IN-LINE PKG
U2 351-1110-020 MICROCIRCUIT, LINEAR: OPERATIONAL AMPLIFIER, ±18 VOLTS SUPPLY, 8
LEAD PLASTIC DUAL IN-LINE PKG
U3 351-1110-020 MICROCIRCUIT, LINEAR: OPERATIONAL AMPLIFIER, ± 18 VOLTS SUPPLY, 8
LEAD PLASTIC DUAL IN-LINE PKG
U4 351-1110-020 MICROCIRCUIT, LINEAR: OPERATIONAL AMPLIFIER, ± 18 VOLTS SUPPLY, 8
LEAD PLASTIC DUAL IN-LINE PKG
U5 351-1137-020 MICROCIRCUIT, LINEAR: TIMER, + 18V, 600 MW
VR1 353-6481-260 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 10 VOLT

6-34 Change 4
816R-2C PARTS LISTS

PL180161-1 CCA, POWER MONITOR/CONTROL - Continued Rev.G

Ref. Des. Part No. Description

VR2 351-1124-130 MICROCIRCUIT, LINEAR: VOLTAGE REGULATOR -12 INPUT -35 VOLTS,
TO-220 PKG
VR3 351-1120-040 MICROCIRCUIT, LINEAR: +12 V @ 1 A VOLTAGE REGULATOR TO-220
PLASTIC PACKAGE
VR4 353-6481-260 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 10 VOLT
XK1 220-0049-010 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 14 POSTS
XUl 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU2 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU3 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU4 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS
XU5 220-0049-100 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 8 POSTS

Change 4 6-35
o
t=J I::J
B B
DS1
c=J DS2 U
c=J DS3 S3 82 81
c=J D84

FRONT VIEW

~ EFJEJ EJBBfB ~~ ~8~~~~: VR1 8


o 5U~~D C10 C11

R6 ~ uQ4

95G0182

REAR VIEW

. C ard Assemb I y, A2A?..


Figure 6-8. Car d Cage Comp onent CircuIt
816R-2C PARTS LISTS

PL189620-1 CCA, CARD CAGE COMPONENT Rev.E

Ref. Des. Part No. Description

C1 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC


C2 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±100/0, 50 WVDC
C3 913 -7016-51 0 CAPACITOR, FIXED, CERAMIC: 10,000 PF, ±5%, 50 WVDC
C4 184-9612-010 CAPACITOR, FIXED, ELECTROLYTIC: 100 UF, ±100/0, 6.3 WVDC
C5 183-5018-070 CAPACITOR, FIXED, ELECTROLYTIC: 1 UF, ±100/0, 35 WVDC DIPPED
TANTALUM
C6 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C7 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C8 183-5018-070 CAPACITOR, FIXED, ELECTROLYTIC: 1 UF, ±10%, 35 WVDC DIPPED
TANTALUM
C9 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C10 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±100/0, 50 WVDC
C11 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 50 WVDC
C12 CK05BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±100/0, 50 WVDC
CR1 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR2 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR7 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR8 353-3763-010 SEMICONDUCTOR DEVICE, DIODE: SILICON, 100V PlY, 300MA FAST
RECOVERY, DO-35 PKG (TYPE lN4148)
CR9 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
DS1 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS2 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25 "LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS3 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS4 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
J1 372-9765-020 CONNECTOR, RECEPTACLE, ELECTRICAL: 20 POSITIONS SINGLE ROW,
SHROUDED HEADER, SQ STRAIGHT POST
K1 410-6009-010 RELAY, SOLID STATE: VOLTAGE 20-140 VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
K2 410-6009-010 RELAY, SOLID STATE: VOLTAGE 20-140 VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
K3 410-6204-030 RELAY, ELECTROMAGNETIC: 4PDT, 2AMP, 28VDC/120VAC CONT 24VDC
COILS, DUAL COIL LATCHING, PC MOUNT
K4 410-6009-010 RELAY, SOLID STATE: VOLTAGE 20-140 VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
K5 410-6009-010 RELAY, SOLID STATE: VOLTAGE 20-140 VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
K6 410-6009-010 RELAY, SOLID STATE: VOLTAGE 20-140 VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
K7 410-6009-010 RELAY, SOLID STATE: VOLTAGE20-l40VAC, 1.0 AMP LOAD CURRENT AT 40
DEG C, 3.5 VDC ACTUATING
R1 747-0998-950 RESISTOR, FIXED, WIRE WOUND: 8870 OHM, ± 10/0, 3 WATT INDUCTIVE
WOUND, SILICONE-CERAMIC COATING

Change 4 6-37
PARTS LISTS 816R-2C

PL189620-1 CCA, CARD CAGE COMPONENT Continued Rev.E

Ref. Des. Part No. Description

R2 747-0998-800 RESISTOR, FIXED, WIREWOUND: 6190 OHMS, ±l%, 3 WATT INDUCTIVE


WOUND, SILICONE-CERAMIC COATING
R3 724-5070-010 RESISTOR, FIXED, FILM: 6200 OHM, ±50/0, 1 WATT, 350 WVDC METAL FILM
OXIDE
R4 382-1405-210 RESISTOR, VARIABLE, NONWIRE WOUND: 5000 OHMS, ±100/0 1/2 WATT,
CERMET
R5 747-0998-950 RESISTOR, FIXED, WIRE WOUND: 8870 OHM, ± 1%, 3 WATT INDUCTIVE
WOUND, SILICONE-CERAMIC COATING
R6 747-5491-000 RESISTOR, FIXED, WIRE WOUND: 33 OHMS, ±50/0, 6.5 WATT
R7 747-0998-800 RESISTOR, FIXED, WIREWOUND: 6190 OHMS, ± 10/0, 3 WATT INDUCTIVE
WOUND, SILICONE-CERAMIC COATING
R8 747-0998-800 RESISTOR, FIXED, WIREWOUND: 6190 OHMS, ±10/0, 3 WATT INDUCTIVE
WOUND, SILICONE-CERAMIC COATING
R9 724-5070-010 RESISTOR, FIXED, FILM: 6200 OHM, ±5%, 1 WATT, 350 WVDC METAL FILM
OXIDE
RIO 724-5070-010 RESISTOR, FIXED, FILM: 6200 OHM, ±50/0, 1 WATT, 350 WVDC METAL FILM
OXIDE
Rll 724-5052-775 RESISTOR, FIXED, FILM: 75KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R12 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R13 724-5052-780 RESISTOR, FIXED, FILM: 82.5KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R14 724-5052-780 RESISTOR, FIXED, FILM: 82.5KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
SI 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
S2 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
S3 266-9952-020 SWITCH, PUSH: SPDT, MOMENTARY, BLACK KEYCAP, 60 VDC MAX, 10
MADCMAX
Ul 351-4706-010 MICROCIRCUIT, LINEAR: DUAL TIMER, + 16 V, 600 MW
U2 351-5305-010 MICROCIRCUIT, DIGITAL: LOW POWER SCHOTTKY, DIVIDE BY 12
COUNTER, 14 PIN DIP, PLASTIC PACKAGE
U3 351-4750-010 MICROCIRCUIT, DIGITAL: DECODER, 3 LINE TO 8 LINE, TTL, LOW POWER
SCHOTTKY, 16 PIN PLASTIC DIP PKG
U4 351-7630-010 MICROCIRCUIT, DIGITAL: LOGIC GATE
U5 736-7026-040 RESISTOR NETWORK: 8 RESISTORS, 47 OHM, ±20/o 1/4 WATT/RESISTOR, 16
PIN DIP PACKAGE, 2.4 WATT/PKG
U6 351-4864-010 MICROCIRCUIT, LINEAR: TRANSISTOR ARRAY, HIGH VOLTAGE, HIGH CUR,
DARLINGTON PAIRS, 7 CKT, 16 PIN PLASTIC DIP
U7 351-7740-010 MICROCIRCUIT, DIGITAL: TTL QUAD 2 INPUT OR GATE, 14 LEAD PLASTIC
DUAL IN-LINE PACKAGE
VRI 351-1120-010 MICROCIRCUIT, LINEAR: +5 V @ 1 A VOLTAGE REGULATOR TO-220
PLASTIC PACKAGE
VR2 353-64 81-13 0 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 5.6 VOLT
VR3 353-6481-11 0 SEMICONDUCTOR DEVICE, DIODE: ZENER, 5.1 V, ±5%, 1WATT AXIAL LEADS,
MOLDED BODY
XKl 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING

6-38 Change 4
816R-2C PARTS LISTS

PL189620-1 CCA, CARD CAGE COMPONENT Continued Rev.E

Ref. Des. Part No. Description

XK2 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,


0.3" WIDE PIN SPACING
XK3 220-6017-160 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 28 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XK4 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XK5 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XK6 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XK7 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XUl 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU2 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU3 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU4 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU5 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU6 220-6017-040 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 16 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU7 220-6017-030 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 14 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING

Change 4 6-39
PARTS LISTS 816R-2C

8 T85 1 8 T84 1 8 T83 1 8 T82 1 8 T81 1

IfTTll-llllfT11l-llllfTTll-llllfTTll-llllfTTll-,ll
I I I I I I I I II I I I I I I I II I I I I I I I II I I I I I I I I I I I I I I I I I
-c=J-R6
LLl~~~_LL~LLli~~_LL~LLl~~~_LL~LLLi~~_LL~LLli~~_LL~
16 9 16 9 16 9 16 9 16 9 J9

2 2
J

1f1 60

J8 J7 J6 15:: 16 J3
F'-
0:::

(J)
0:::
0
a: 0 J10

0 4 0 4
~ Q 8~~
50

60

93G0324

JUMPERS LOCATED AT: J115T06


9 TO 10
13 TO 14
15 TO 16

J12 7 TO 8
9 TO 10

J133T04
5 TO 6
7 TO 8

Figure 6-9.. Backplane Circuit Card Assembly, A2A8..

6-40 Change 4
816R-2C PARTS LISTS

PL180194-1 CCA, BACKPLANE Rev.G

Ref. Des. Part No. Description

C1 183-1281-080 CAPACITOR, FIXED, ELECTROLYTIC: 100 UF, +85-10%, 50WVDC ALUMINUM,


INSULATED, AXIAL LEADS, .385" D, 1.536" L
C2 183-1281-080 CAPACITOR, FIXED, ELECTROLYTIC: 100 UF, +85-10%, 50WVDC ALUMINUM,
INSULATED, AXIAL LEADS, .385" D, 1.536" L
CR1 353-6442-030 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 200V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4003)
CR2 353-6442-030 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 200V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4003)
J1 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J2 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J3 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J6 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J7 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J8 372-9753-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 50 PINS, 2 ROW,
STRAIGHT, 0.100 CENTERS
J9 372-9754-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 60 PINS, 2 ROW, RT
ANGLE, 0.100 CTRS, SHROUDED, 0.150 END DIM
J10 372-9754-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 60 PINS, 2 ROW, RT
ANGLE, 0.100 CTRS, SHROUDED, 0.150 END DIM
J11 372-9756-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 16 PINS, 2 ROW,
STRAIGHT, 0.100 X 0.100 CENTERS, UNSHROUDED
J12 372-9756-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 16 PINS, 2 ROW,
STRAIGHT, 0.100 X 0.100 CENTERS, UNSHROUDED
J13 372-9756-010 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 16 PINS, 2 ROW,
STRAIGHT, 0.100 X 0.100 CENTERS, UNSHROUDED
R5 724-5052-665 RESISTOR, FIXED, FILM: 22.lKOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R6 724-5053-280 RESISTOR, FIXED, FILM: 4750HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R7 724-5053-280 RESISTOR, FIXED, FILM: 4750HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R8 724-5052-200 RESISTOR, FIXED, FILM: 1000HM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R9 724-5053-260 RESISTOR, FIXED, FILM: 3320HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RIO 724-5053-250 RESISTOR, FIXED, FILM: 2740HM, ±1%, 1/2WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
TBI 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG
TB2 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG
TB3 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG
TB4 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG
TB5 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG

Change 4 6-41
PARTS LISTS 816R-2C

o
o o

~
00
00

81 C1 E3

R1

00

R2

93G0325
Figure 6-10. Power Control Assembly, A2A9.

6-42 Change 4
816R-2C PARTS LISTS

PL172715-1 POWER CONTROL ASSEMBLY Rev.B

Ref. Des. Part No. Description

B1 230-5006-010 GEARCASE-MOTOR: 10RPM, 5 OZ-IN OUTPUT TORQUE, 120V 60HZ, REVERSIBLE, 30:
1 GEAR RATIO, BRASS GEARS
C1 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±20%, 500 WVDC
C2 933-5005-010 CAPACITOR, FIXED, FILM: 0.1 MicroF, ±10%, 600 WVDC POLYPROPYLENE FILM,
RADIAL LEADS, 0.75"DIA, 1.30"LG
CR1 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON,lAMP,1000V PRY DO-41 EPOXY
PKG,AXIAL LEADS (IN4007)
E1 306-0234-000 POST, ELECTRICALIMECHANICAL EQUIPMENT: 4-40 THREADS, 0.625 LENGTH, 6500
VOLTS AC-RMS
E2 306-0234-000 POST, ELECTRICALIMECHANICAL EQUIPMENT: 4-40 THREADS, 0.625 LE,NGTH, 6500
VOLTS AC-RMS
E3 306-0234-000 POST, ELECTRICALIMECHANICAL EQUIPMENT: 4-40 THREADS, 0.625 LENGTH, 6500
VOLTS AC-RMS
E4 306-0234-000 POST, ELECTRlCAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625 LENGTH, 6500
VOLTS AC-RMS
R1 381-1648-020 RESISTOR, VARIABLE, WIRE WOUND: 5000 OHM, ±5%, 2 WATT LINEAR TAPER, 10
TURN, PRECISION, BUSHING MOUNT
R2 724-5054-250 RESISTOR, FIXED, FILM: 100 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPMIDEGC, COLOR BANDED

Change 5 6-43
PARTS LISTS 816R-2C

DC1 R1 R3 R5
F1
o XF1

0
+

R2
A3 0

. C1
$ 0

9!F
~ $
TB1
0 0

¥ +
®oo®
~
$
@
E1
@
E2

a ~~Iee
: G3'" S"
...

~SG~ gi
' (Do G>
.
DD ~ OM ~ G3
Q~§!
o f:J 88~
~ 000 C2

A2 B1 A1 M1

Figure 6-11. Intermediate Power Amplifier Assembly, A3.

6-44 Change 4
816R-2C PARTS LISTS

PL180302-2 IPA ASSEMBLY Rev.G

Ref. Des. Part No. Description

Al *195079-1 CCA, METERING CARD


A2 *189625-1 IPA STATUS BOARD
A3 *193773-1 AMPLIFIER ASSY
Bl 009-5057-010 FAN, CENTRIFUGAL: DOUBLE, 185 CFM, 230 VAC, 60 HZ, UL/CLA BALL
BEARING MOTOR
Cl 183-1278-660 CAPACITOR, FIXED, ELECTROLYTIC: 120000 UF, +75-10%,60 WVDC,
ALUMINUM DIELECTRIC, 1/4-28 TERMINALS
C2 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PF, ±5%, 500 WVDC
C3 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±20%, 500 WVDC
DC1 277-3039-010 COUPLER, DIRECTIONAL: 88-108 MHZ, 1.20: 1 VSWR MAX POWER 1000
WATTS MAX, DIRECTIVITY 30 DB MIN, CUSTOM
E1 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E2 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
F1 264-5209-010 FUSE: 30 AMPS, 125 VOLTS
Ml 450-8023-010 POWER METER, RF: 3-1/2", RECTANGULAR, FLANGE, PANEL MOUNT,
RANGE-0-120%, 0-3 AMPS
R1 * 159682-1 SHUNT ASSEMBLY
R2 716-0060-080 RESISTOR, ADJUSTABLE, WIRE WOUND: 50 OHM, ±10%, 100 WATT, 1.41 MAX
AMP .
R4 724-5054-370 RESISTOR, FIXED, FILM: 1000 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
TB1 367-0926-000 TERMINAL BOARD: 20 TERMINALS, 20 AMP, 3000 VOLTS, #6-32 X 1/4 BRASS,
NP SCREWS, 16-14 AWG, PHENOLIC
XF1 265-9514-020 FUSEHOLDER, BLOCK: 30 AMP, SCREW TERMINALS, RATED @ 600 VOLTS, 1
POSITION

Change 4 6-45
PARTS LISTS 816R-2C

o o
51

-1 R3i ~

[j R2 R3

[:]
-
~
~
-1
-1
R2i

R20
~
l-
[:J -
-
- -cg-~
--
~
20
Q2] - -
~ -

80
......
- ......
XU2 ~ -
VRi
~

~ -1 R24
r- - -
II
E2
0
~
~ L:]( C3
J
I

I~ IJi ~~
---c=IJ--
P1
0
Ei I~ IJ2
-1
-1
Ri9

Ri8
~
~
G~
~
R23

-[0---
CRi

G ~
~
-1 R17

[§]
~
[£] XUi
( C4
J
VR2

R33

8 -1 R9 ~
-1 R8 ~
-1
-1
Ri6

Ri5
r-
r-
c::;J
( C5
)
~
1
- ~

OOGOOO2

Figure 6-12e IPA Metering Circuit Card Assembly, A3Al.

6-46 Change 4
816R-2C PARTS LISTS

PL195079-1 CCA, METERING CARD Rev. A

Ref. Des. Part No. Description

C1 913-3279-200 CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±20%, 50 WVDC


C2 913-3279-200 CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±20%, 50 WVDC
C3 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PF, ±50/0, 500 WVDC
C4 CM05FD101J03 CAPACITOR, FIXED, MICA: 100 PF, ±50/0, 500 WVDC
C5 CM05FDI01J03 CAPACITOR, FIXED, MICA: 100 PF, ±50/0, 500 WVDC
C6 913-3279-200 CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±20%, 50 WVDC
C7 913-3279-200 CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±20%, 50 WVDC
CR1 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
J1 372-9643-040 CONNECTOR, RECEPTACLE, ELECTRICAL: PWB MOUNT, 3 PIN, SINGLE
ROW, STRAIGHT, 0.100 CENTER, GOLD PLATED
J2 372-9643-040 CONNECTOR, RECEPTACLE, ELECTRICAL: PWB MOUNT, 3 PIN, SINGLE
ROW, STRAIGHT, 0.100 CENTER, GOLD PLATED
PI 372-9754-260 CONNECTOR, RECEPTACLE, ELECTRICAL: HEADER, 20 PINS 1 ROW, RT
ANGLE, 0.1" CENTERS, SHROUDED PROFILE
Q1 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
Q2 352-0661-020 TRANSISTOR: NPN, SILICON, 800MA, 70V, 500MW DISS TO-18 PKG (2N2222A)
R1 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R2 724-5053-650 RESISTOR, FIXED, FILM: 22.1KOHM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R3 724-5053-510 RESISTOR, FIXED, FILM: 75000HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R4 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R5 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R6 724-5052-510 RESISTOR, FIXED, FILM: 39200HM, ±1 0/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R7 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R8 724-5052-200 RESISTOR, FIXED, FILM: 1000HM, ±10/0, 1/4WATT@70C 1t1ETAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R9 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RIO 724-5052-460 RESISTOR, FIXED, FILM: 22100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R11 724-5052-200 RESISTOR, FIXED, FILM: 1000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R12 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R13 724-5052-490 RESISTOR, FIXED, FILM: 33200HM, ±1 %, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R14 382-1405-080 RESISTOR, VARIABLE, NONWIRE WOUND: 20K OHMS, ± 100/0 1/2 WATT,
CERMET
R15 724-5052-520 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R16 724-5052-520 RESISTOR, FIXED, FILM: 47500HM, ±1 %, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R17 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±l%, 1/4WATT@70CMETAL FILM,
TC=100PPM/DEGC, COLOR BANDED

Change 4 6-47
PARTS LISTS 816R-2C

PL195079-1 CCA, METERING CARD - Continued Rev. A

Ref. Des. Part No. Description

R18 724-5052-510 RESISTOR, FIXED, FILM: 39200HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R19 724-5052-510 RESISTOR, FIXED, FILM: 39200HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R20 724-5052-740 RESISTOR, FIXED, FILM: 47.5KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R21 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R22 382-1405-080 RESISTOR, VARIABLE, NONWIRE WOUND: 20K OHMS, ±10% 1/2 WATT,
CERMET
R23 382-1405-080 RESISTOR, VARIABLE, NONWIRE WOUND: 20K OHMS, ±10O/o 1/2 WATT,
CERMET
R24 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPMlDEGC, COLOR BANDED
R25 724-5052-800 RESISTOR, FIXED, FILM: 100KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R26 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R27 382-1405-050 RESISTOR, VARIABLE, NONWIRE WOUND: 2000 OHMS, ±10O/o 1/2 WATT,
CERMET
R28 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R29 724-5052-400 RESISTOR, FIXED, FILM: 10000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPMlDEGC, COLOR BANDED
R30 724-5052-800 RESISTOR, FIXED, FILM: 100KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R31 724-5052-735 RESISTOR, FIXED, FILM: 46.4K OHM, ±1%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R32 382-1405-100 RESISTOR, VARIABLE, NONWIRE WOUND: 50K OHMS, ±10o/~ 1/2 WATT,
CERMET
R33 724-5055-370 RESISTOR, FIXED, FILM: 1000 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
Sl 266-9731-010 SWITCH ASSEMBLY, PUSHBUTTON: 4 PDT, 4 POSITION, 12 CONTACTS,
INTERLOCK
U1 351-1211-040 MICROCIRCUIT, LINEAR: DUAL OP-AMP 8 PIN PLASTIC DIP PKG
U2 351-1211-040 MICROCIRCUIT, LINEAR: DUAL OP-AMP 8 PIN PLASTIC DIP PKG
VR1 351-1120-040 MICROCIRCUIT, LINEAR: +12 V @ 1 A VOLTAGE REGULATOR TO-220
PLASTIC PACKAGE
VR2 353-6481-330 SEMICONDUCTOR DEVICE, DIODE: ZENER, 15 VDC, 1 WATT, COMMERCIAL
XU1 220-6017-020 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 8 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU2 220-6017-020 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 8 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING

6-48 Change 4
816R-2C PARTS LISTS

PL189625-1 IPA STATUS BOARD Rev. A

Ref. Des. Part No. Description

DS 1 419-0089-010 DISPLAY, OPTOELECTRONIC: LED, GREEN, .5"X.25"LIGHTED AREA, 4.5MCD


INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE
DS2 419-0089-020 DISPLAY, OPTOELECTRONIC: LED, RED, .5"X.25"LIGHTED AREA, 4.5MCD
INTENSITY, RECT, PC MOUNT, DUAL-IN-LINE

It II DS1
Q II DS2

o o

0080003

Figure 6-13. LED Assembly, A3A2.

Change 4 6-49
PARTS LISTS 816R-2C

T81 CR1 CR2

F1 tt> <f>
XF1

F2
XF2

P1
J2

J1

P2

tt> (f) <±)

R2

A1 -4---H+---
A2

(f)
<±>

0 0 R1

TP2
¥ TP1

tt> <f>
98GOO88

Figure 6-14. Amplifier Assembly, A3A3 .

6-50 Change 4
816R-2C PARTS LISTS

PL193773-1 AMPLIFIER ASSEMBLY Rev.H

Ref. Des. Part No. Description

Al *189215-1 AMPLIFIER MODULE


A2 *189215-1 AMPLIFIER MODULE
CRI 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON,lAMP,1000V PRY DO-41 EPOXY
PKG,AXIAL LEADS (lN4007)
CR2 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON,lAMP,1000V PRY DO-41 EPOXY
PKG,AXIAL LEADS (lN4007)
Fl 264-5224-040 FUSE,CARTRIDGE:12AMP,60V,CERAMIC BODY,1/4"Xl-1/4" VERY FAST
ACTING,SEMICONDUCTOR PROTECTION
F2 264-5224-040 FUSE,CARTRIDGE:12AMP,60V,CERAMIC BODY,1/4"Xl-l/4" VERY FAST
ACTING,SEMICONDUCTOR PROTECTION
PI 361-5028-060 CONNECTOR,PLUG,ELECTRICAL:5 #20 SOCKET & 2 #8 CAVITIES,"D"SUB
TYPE, 15 CONT SHELL SZ,SOLDER TERM
P2 361-5028-060 CONNECTOR,PLUG,ELECTRICAL:5 #20 SOCKET & 2 #8 CAVITIES,"D"SUB
TYPE, 15 CONT SHELL SZ,SOLDER TERM
Rl 714-7039-070 RESISTOR,FIXED,FILM:I00 OHM,+-5%,40 WATT CHIP TYPE,DOUBLE FLANGE
MOUNT
R2 714-7051-020 RESISTOR,FIXED,FILM:100 OHM,+-5%,250 WATT CHIP TYPE,DOUBLE FLANGE
MOUNT
TBI 367-0910-000 TERMINAL BOARD:4 TERMINALS,20 AMP,3K VRMS, #6-32 X 1/4 BRASS,NP
SCREWS,16-14 AWG,PHENOLIC
TPI 306-0976-000 TERMINAL,STUD:6K VOLT,5/8 X 4-40UNC-2B THD
TP2 306-0976-000 TERMINAL,STUD:6K VOLT,5/8 X 4-40UNC-2B THD
WI *195442-1 CABLE,INLET
W2 *195443-1 CABLE ASSEMBLY
W3 *195443-1 CABLE ASSEMBLY
W4 *195444-1 CABLE ASSEMBLY
W5 *195444-1 CABLE ASSEMBLY
W6 *195445-1 CABLE ASSEMBLY
W7 *195445-1 CABLE ASSEMBLY
W8 *195446-1 CABLE ASSEMBLY
W9 *195446-1 CABLE ASSEMBLY
WI0 *195447-1 CABLE ASSEMBLY
Wl1 *195373-1 BUS CABLE ASSEMBLY
W12 *195373-1 BUS CABLE ASSEMBLY
XFl 265-9534-010 FUSEHOLDER:SINGLE POLE,FOR 1/4 X 1-1/4 FUSES
XF2 265-9534-010 FUSEHOLDER:SINGLE POLE,FOR 1/4 X 1-1/4 FUSES

Change 5 6-51
PARTS LISTS 816R-2C

P1 51

A1 A2

o ~
J2
J1 o @ o
o
C1 ....· lo~~
+: ..... 00
0: o
C2·····
R2 1-
t:O'- 0
~ o
R3····· u..i -t::==::!-J

96G0264

Figure 6-15. Amplifier Module, A3A3A1-A2.

6-52
Change 4
816R-2C PARTS LISTS

PL189215-1 AMPLIFIER MODULE Rev.D

Ref. Des. Part No. Description

Al *189213-1 CCA, RF
A2 *189210-1 CCA, CONTROL
C1 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±10%, 100 WVDC
C2 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±lO%, 100 WVDC
J1 361-5028-050 CONNECTOR, RECEPTACLE, ELECTRICAL: 5 #20 PINS AND 2 #8 CAVITIES,
"D"SUB TYPE, 15 CONT SHELL SZ, SOLDER TERM
J2 361-5065-010 CONNECTOR, RECEPTACLE, ELECTRICAL: BNC, BULKHEAD JACK
L1 288-4029-020 SHIELDING BEAD, ELECTRONIC: FERRITE, 5-30MHZ OPER FRE 0.385"OD,
0.193"ID, 0, 410"LO, Z=80 OHM@100MHZ@25C
Q1 352-5134-010 TRANSISTOR: FET, DUAL, RF, 300W, 2-175 MHZ, N CHANNEL TAB LEADS,
CHASSIS MOUNT
R1 NOT-USED
R2 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPM/DEGC, COLOR BANDED
R3 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
Sl 267-5022-010 SWITCH, THERMOSTATIC: 80C, ±5DEG, CLOSE ON TEMP RISE BIMETALLIC,
SNAP ACTION, TO-220 TYPE PKG

Change 4 6-53
PARTS LISTS 816R-2C

96G0500

Figure 6-16. CCA, RF, A3A3A1-A2A1.

6-54 Change 4
816R-2C PARTS LISTS

PL189213-1 CCA,RF Rev.E

Ref. Des. Part No. Description

C101 917-2006-010 CAPACITOR, VARIABLE, CERAMIC: 8-50PF, 250WVDC STRIPLINE LEADS,


TC=-1500±900PPM/DEGC
C102 913-7144-510 CAPACITOR, FIXED, CERAMIC: 120 PF, ±10%, 50 WVDC, CHIP TYPE, COG
TEMP CHAR, WRPRND TERM, SURF MT, EIA SZ 1206
C103 913-7143-650 CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 50 WVDC, CHIP TYPE, X7R
TEMP CHAR, WRPRND TERM, SURF MT, EIA SZ 1206
C104 CK06BX105K CAPACITOR, FIXED, CERAMIC: 1 UF, ±10%, 50 WVDC
C105 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 100 WVDC
C106 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 UF, ±10%, 100 WVDC
C107 913-7135-030 CAPACITOR, FIXED, CERAMIC: 1000PF, ±5%, 50WVDC, CHIP TYPE SURFACE
MT, TC=P90±30PPM/DEGC, CASE SIZE B
C108 913-7135-030 CAPACITOR, FIXED, CERAMIC: 1000PF, ±5%, 50WVDC, CHIP TYPE SURFACE
MT, TC=P90±30PPM/DEGC, CASE SIZE B
C109 913-7143-650 CAPACITOR, FIXED, CERAMIC: 0.01 UF, ±10%, 50 WVDC, CHIP TYPE, X7R
TEMP CHAR, WRPRND TERM, SURF MT, EIA SZ 1206
ClIO 183-5106-040 CAPACITOR, FIXED, ELECTROLYTIC: 10UF, +75-10%, 150WVDC ALUMINUM,
INSULATED, AXIAL LEADS, + 105C, LONG LIFE
LI02 288-4029-020 SHIELDING BEAD, ELECTRONIC: FERRITE, 5-30MHZ OPER FRE 0.385"OD,
0.193"ID, 0, 410"LG, Z=80 OHM@100MHZ@25C
LI03 288-4029-020 SHIELDING BEAD, ELECTRONIC: FERRITE, 5-30MHZ OPER FRE 0.385"OD,
0.193"ID, 0, 410"LG, Z=80 OHM@100MHZ@25C
R101 724-5054-310 RESISTOR, FIXED, FILM: 330 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R102 724-5055-170 RESISTOR, FIXED, FILM: 22 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
RI03 724-5055-170 RESISTOR, FIXED, FILM: 22 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
RI04 724-5055-170 RESISTOR, FIXED, FILM: 22 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
RI05 724-5055-170 RESISTOR, FIXED, FILM: 22 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
RI06 714-7059-030 RESISTOR, FIXED, FILM: 7.5 OHM, ±1%, 20 WATT @ 25C TO-220 TYPE PKG,
METAL TAB, NON-INDUCTIVE
RI07 724-5053-475 RESISTOR, FIXED, FILM: 39200HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RI08 724-5053-475 RESISTOR, FIXED, FILM: 39200HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RI09 382-1405-060 RESISTOR, VARIABLE, NONWIRE WOUND: 5000 OHMS, ±1 0% 1/2 WATT,
CERMET
R110 724-5053-420 RESISTOR, FIXED, FILM: 1500 OHM, ±l%, 1/2 WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
RIll 724-5054-310 RESISTOR, FIXED, FILM: 330 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R112 724-5055-130 RESISTOR, FIXED, FILM: 10 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
TI01 288-4020-020 CORE, ELECTROMAGNET: BALUN, TWO HOLE, 125MHZ MAX FREQ FERRITE,
0.295"THK, 0.525"W, 0.565"LG

Change 4 6-55
PARTS LISTS 816R-2C

o
R204 r-----

Cf) --~
--~
<
JJ
I\)
o
---,I

D~
R202
C204
o -E)l-----0
~ R201

-----------J
f21t~~
6: ~ I ~--:-- 0 g
~I I
~o m ~F 0 ~O-~~
~-.., --J 0G~

jT6
___________J--r- £)~ a5

~C20~R223 0 :~~~r ~
(j) K5 R216
C201
R215 ~ K5
m ~Gr5l 0 ~
"" 0 6 ~
D G-R224
CR203

R2~
o
g
X c
~ 2 ~2~ (,)g209
o ~OY-E) ~'r~ 0 R222 <D

96G0311

Figure 6-17~ Control Circuit Card Assembly, A3A3Al-A2A2.

6-56 Change 4
816R-2C PARTS LISTS

PL189210-1 CCA, CONTROL Rev.C

Ref. Des. Part No. Description

C201 913-7143-770 CAPACITOR, FIXED, CERAMIC: O.lMicroF, ±10%, 50WVDC, CHIP TYPE, SURF
MT, X7R TEMP CHAR, WRPRND TERM, EIA SZ 1206
C202 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±10%, 100 WVDC
C203 913-7143-770 CAPACITOR, FIXED, CERAMIC: O.lMicroF, ±10%, 50WVDC, CHIP TYPE, SURF
MT, X7R TEMP CHAR, WRPRND TERM, EIA SZ 1206
C204 913-7145-210 CAPACITOR, FIXED, CERAMIC: .010 MicroF, ±10%, 100WVDC, CHIP TYPE,
SURF MT, X7R TEMP CHAR, WRPRND TERM, EIA SZ 1206
C205 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C206 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C207 NOT-USED
C208 CK05BX103K CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±10%, 100 WVDC
C209 CK05BX223K CAPACITOR, FIXED, CERAMIC: 0.022 MicroF, ±10%, 50 VOLT
CR201 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
CR202 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
CR203 353-6442-040 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 400V PRV DO-41 EPOXY
PKG, AXIAL LEADS (lN4004)
E1 REFERENCE
E2 REFERENCE
E3 REFERENCE
E4 REFERENCE
E5 REFERENCE
E6 REFERENCE
E7 REFERENCE
Q201 352-5104-010 TRANSISTOR: SILICON, PNP, 200MADC, 40V C-E, 350 MW 250MHZ, TO-92
PLASTICPKG
Q202 353-5356-010 SEMICONDUCTOR DEVICE, THYRISTOR: SCR, 100V PRY, 0.8AMP TO-226AA
PLASTICPKG
Q203 352-5188-010 TRANSISTOR: POWER MOSFET, P-CHANNEL, -1 00 VOLTS VDS RDS=0.20HM,
ID=21AMP, PD=150WATTS, TO-247AC(TO-3P)PKG
R201 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R202 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R203 382-1405-050 RESISTOR, VARIABLE, NONWIRE WOUND: 2000 OHMS, ±10% 1/2 WATT,
CERMET
R204 724-5052-230 RESISTOR, FIXED, FILM: 1620HM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R205 724-5052-405 RESISTOR, FIXED, FILM: 1100 OHM, ±1%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R206 724-5053-600 RESISTOR, FIXED, FILM: 10KOHM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R207 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R208 724-5052-595 RESISTOR, FIXED, FILM: 32.4KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R209 714-7059-040 RESISTOR, FIXED, FILM: 0.05 OHM, ±l%, 20 WATT @ 25C TO-220 TYPE PKG,
METAL TAB, NON-INDUCTIVE

Change 4 6-57
PARTS LISTS 816R-2C

PL189210-1 CCA, CONTROL - Continued Rev.C

Ref. Des. Part No. Description

R210 724-5052-675 RESISTOR, FIXED, FILM: 24.9K OHM, ±l%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R211 724-5052-675 RESISTOR, FIXED, FILM: 24.9K OHM, ±1%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R212 724-5052-520 RESISTOR, FIXED, FILM: 47500HM, ±1%, 1/4WATT@70CMETAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R213 724-5052-530 RESISTOR, FIXED, FILM: 51100HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R214 382-1405-030 RESISTOR, VARIABLE, NONWIRE WOUND: 500 OHMS, ±10% 1/2 WATT,
CERMET
R215 724-5052-880 RESISTOR, FIXED, FILM: 332KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R216 724-5052-240 RESISTOR, FIXED, FILM: 2000HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPMIDEGC, COLOR BANDED
R217 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ± 10/0, 114WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R218 724-5052-880 RESISTOR, FIXED, FILM: 332KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R219 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R220 382-1405-060 RESISTOR, VARIABLE, NONWIRE WOUND: 5000 OHMS, ±10% 1/2 WATT,
CERMET
R221 724-5052-600 RESISTOR, FIXED, FILM: 10KOHM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R222 724-5052-405 RESISTOR, FIXED, FILM: 1100 OHM, ±l%, 1/4 WATT @ 70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R223 724-5052-260 RESISTOR, FIXED, FILM: 3010HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R224 724-5052-310 RESISTOR, FIXED, FILM: 6810HM, ±1%, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R225 724-5052-285 RESISTOR, FIXED, FILM: 4750HM, ±15, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R226 724-5052-010 RESISTOR, FIXED, FILM: 100HM, ±10/0, 1/4WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R227 724-5052-800 RESISTOR, FIXED, FILM: 100KOHM, ±l%, 1/4WATT@70C METAL FILM,
TC=lOOPPMIDEGC, COLOR BANDED
U201 351-5402-010 MICROCIRCUIT, LINEAR: DUAL OP AMPS, WIDE BAND, 5 MHZ SINGLE
SUPPLY, 8 PIN PLASTIC DIP PKG
U202 419-0121-010 COUPLER, OPTOELECTRONIC: SNGL CHANNEL, NPN TRANSISTOR OUT,
VCE=70V MIN, LED IN, STD 6 PIN PLASTIC DIP PKG
VR201 351-5403-010 MICROCIRCUIT, LINEAR: VOLTAGE REGULATOR, ADJ, POS OUT 1.2-57V,
1.5AMP, 3 TERMINAL, TO-220 PLASTIC PKG
XU201 220-6017-020 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 8 CONTACTS OPEN FRAME,
0.3" WIDE PIN SPACING
XU202 220-6017-010 SOCKET, PLUG-IN ELECTRONIC COMPONENT: 6 CONTACTS, OPEN FRAME,
0.3"WIDE PIN SPACING, 0.4"WIDE BODY

6-58 Change 4
816R-2C PARTS LISTS

(This Page Intentionally Left Blank)

Change 4 6-59
PARTS LISTS 816R-2C

T3 54
(REF) (REF) C4 R12 CR2 VR2 C6 CR3 R10 C1
\
\
\
\
\
\
\
\
\
55
53
.
i \
(REF)

(REF)
/ C3
R9
R11
L----R4
R3
R17 R13
C5

R1

51
(REF)

R14 R15 R16 R18 A1 R8 R7 52 R5 R6


93G0329
(REF)

Figure 6-18. Component Shelf Assembly, AS.

6-60 Change 4
816R-2C PARTS LISTS

PL180317-3 COlVIPONENT SHELF ASSEMBLY Rev.P

Ref. Des. Part No. Description

Al * 180386-1 CCA,IP METERING ASSEMBLY


Cl 930-5070-010 CAPACITOR,FIXED,PAPER:0.03 VF,+/-l 00/0, 15K WVDC
C2 930-5040-020 CAPACITOR,FIXED,PAPER:25 VF,+/-10%,2000 WVDC METAL CAN,WITH
TERMINALS
C3 933-5016-010 CAPACITOR,FIXED,PAPER:0.05 UF,+-100/0,2000 WVDC
C4 951-0118-000 CAPACITOR,FIXED,PAPER:0.68 UF,+-200/0,200 WVDC
C5 913-1186-000 CAPACITOR,FIXED,CERAM:IC:1000 PF,+-20%,1000 WVDC DISC TYPE
C6 913-3152-000 CAPACITOR,FIXED,CERAMIC:O.l UF,+80 -20%,500 WVDC DISC TYPE,Z5U TEMP
COEFFICIENT
CRI 353-5281-010 RECTIFIER,SEMICONDUCTOR DEVICE:OUTPUT CURRENT 30A FORWARD
VOLTAGE 1.30 VOLTS MAX,3 AC INPUT
CR2 353-5281-010 RECTIFIER,SEMICONDUCTOR DEVICE:OUTPUT CURRENT 30A FORWARD
VOLTAGE 1.30 VOLTS MAX,3 AC INPUT
CR3 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON, 1AMP, 1000V PRY DO-41 EPOXY
PKG,AXIAL LEADS (lN4007)
CR4 353-5224-010 SEMICONDUCTOR DEVICE,DIODE:6 AMP,1000 VOLT
CR5 353-5224-010 SENIICONDUCTOR DEVICE,DIODE:6 AMP, 1000 VOLT
Kl 970-2426-070 RELAY,ELECTROMAGNETIC:24 VDC COIL,20 VDC PULL-IN, 15 VDC DROP-
OUT,132 OHMS,+-15%,COIL RESISTANCE
K2 970-3508-010 RELAY,ELECTROMAGNETIC:SPDT,2AMP@28VDC CONTACT RTG
SENSITIVE,3VDC-20MW COIL,PLASTIC ENCLOSURE,SKT MT
K3 970-3508-010 RELAY,ELECTROMAGNETIC:SPDT,2A1vlP@28VDC CONTACT RTG
SENSITIVE,3VDC-20MW COIL,PLASTIC ENCLOSURE,SKT MT
K4 970-3508-010 RELAY,ELECTROMAGNETIC:SPDT,2AMP@28VDC CONTACT RTG
SENSITIVE,3VDC-20:rvlW COIL,PLASTIC ENCLOSURE,SKT MT
L1 240-4007-020 REACTOR:5 MH,25 AMP DC,DCR=0.025 OHM,100-360 HZ OPEN FRMlIE,DRY
CONSTRUCTION,CHASSIS MOUNT
Rl 705-1493-050 RESISTOR,FIXED,FILM:200K OHMS,+-} 0/0,3 WATT
R2 705-1493-050 RESISTOR,FIXED,FILM:200K OHMS,+-10/0,3 WATT
R3 705-1493-050 RESISTOR,FIXED,FILM:200K OHMS,+-10/0,3 WATT
R4 705-1493-050 RESISTOR,FIXED,FILM:200K OHMS,+-10/0,3 WATT
R5 710-5076-010 RESISTOR,FIXED,WlRE WOUND:! OHMS,+-l%,36 WATT
R6 710-5076-030 RESISTOR,FIXED,WIRE WOUND:0.50HM,+-1 O%,35WATT MIN EDGEWOUND
CORRUGATED RIBBON,
R7 710-5076-060 RESISTOR,FIXED,WlRE WOUND:4 OHMS,+-10%,100 WATT WITH ADJUSTABLE
TAP
R8 710-5076-060 RESISTOR,FIXED,WIRE WOUND:4 OHMS,+-l 0%,1 00 WATT WITH ADJUSTABLE
TAP
R9 746-6070-000 RESISTOR,FIXED,WlREWOUND:300 OHM,+-5%.12 WATT
RIO 716-5014-010 RESISTOR,FIXED,WlRE WOUND:300 OHM,+-5%,25 WATT
R11 RCR32G473JS RESISTOR,FIXED,COMPOSITION:47K OHMS,+-5%,1 WATT
R12 724-5055-210 RESISTOR,FIXED,FILM:47 OHM,+-50/o,2 WATT @ 70C METAL
FILM,TC=250PPMlDEGC,COLOR BANDED
R13 747-5320-000 RESISTOR,FIXED,WIRE WOUND: 10 OHMS,+-5%,3 WATT
R14 746-6145-000 RESISTOR,FIXED,WIRE WOUND: 150 OHMS,+-5%,12 WAlT
R15 377-0619-000 RESISTOR,VARIABLE,WIRE WOUND:50 OHM,+-10%,2 WATT, LINEAR
R16 377-0619-000 RESISTOR,VARIABLE,WIRE WOUND:50 OHM,+-10%,2 WATT, LINEAR
R17 RER75F60R4R RESISTOR,FIXED,WIRE WOUND:60.4 OHM,+-l%,30 WATT, CHASSIS MT,10W
FREE AIR,FR+O.O 1%/1 OOOHR,IND

Change 6 6-61
PARTS LISTS 816R-2C

PL180317-3 COlVIPONENT SHELF ASSEl\1BLY - Continued Rev. P

Ref. Des. Part No. Description

RI8 377-0716-040 RESISTOR,VARIABLE,WIRE WOUND:50 OHMS,+-l 0%,4 WATT LINEAR TAPER


VR1 353-6230-000 SEMICONDUCTOR DEVICE,DIODE:SILICON,MEDIUM POWER VOLTAGE REGULATOR
XK2 220-9037-010 SOCKET,PLUG-IN ELECTRONlC COMPONENT: 10 CONTACT SCREW TERMINALS,FOR 2
POLE RIO RELAY,TRACK MOUNT
XK3 220-9037-010 SOCKET,PLUG-IN ELECTRONlC COMPONENT: 10 CONTACT SCREW TERMINALS,FOR 2
POLE RIO RELAY,TRACK MOUNT
XK4 220-9037-010 SOCKET,PLUG-IN ELECTRONlC COMPONENT: 10 CONTACT SCREW TERMINALS,FOR 2
POLE RIO RELAY,TRACK MOUNT
Zl 270-0080-040 MAGNETIC CIRCUlT,HALLTRON:250MA,20 OHMS,360MH IN 250MV@2 OHMS
OUT,250MA@2.5 OHMS CONTROL

6-62 Change 6
816R-2C PARTS LISTS

(This Page Intentionally Left Blank)

Change 4 6-63
PARTS LISTS 816R-2C

(Y) ~
0::: 0::
> >

95G0188

Figure 6-19. Plate Current Metering Circuit Card Assembly, ASA1"

6-64 Change 4
816R-2C PARTS LISTS

PL180386-1 CCA, IP METERING ASSEMBLY Rev. A

Ref. Des. Part No. Description

C5 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±20%, 500 WVDC


R9 747-9451-000 RESISTOR, FIXED, WIRE WOUND: 0.25 OHMS, ±l%, 10 WATT
R11 724-5054-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R12 724-5054-435 RESISTOR, FIXED, FILM: 3600 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R13 724-5054-380 RESISTOR, FIXED, FILM: 1200 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
TB1 306-3051-020 TERMINAL BOARD: 12 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE
SIZE, PWB MOUNTING, BLUE, 300V, lOA RTG
VR3 353-3121-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 6.8V, ±5%, 1 WATT SILICON,
VOLTAGE REGULATOR, AXIAL LEADS
VR4 353-3121-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 6.8V, ±5%, 1 WATT SILICON,
VOLTAGE REGULATOR, AXIAL LEADS

Change 4 6-65
PARTS LISTS 816R-2C

CBG

e e
CB3

0 AC LINE
0
CB2
CB4

CB1

PA PLATE CBS
28VOC BLOWERS POWER SUPPLY
DRIVER PASCREEN e m
POWER SUPPLY POWER SUPPLY POWER SUPPLY
(! e (! e e (! e (!

0
(I $ (I e
BBB 8BB
(I (i Ql (J)

PA BIAS PA BIAS
FAN FAN FAN POWER SUPPLY POWER SUPPLY FILAMENTS FILAMENTS

0 0 0 0 0 0 0
F7 F9 F12 F4 F5 F3 F1
- - POWER CONTROLAMPUFIER - - EXCITER

o o o o
EXCITER FILAMENT METER CONTROLS
C)
000
F8
C)

F6 F10 F11 F2 F13 F14

93G0330

Figure 6-20. Circuit Breaker Assembly, A6.

6-66 Change 4
816R-2C PARTS LISTS

PL180303-1 CIRCUIT BREAKER ASSEMBLY Rev. -

Ref. Des. Part No. Description

CBl 260-5043-040 CIRCUIT BREAKER: 3 POLE, 5 AMP, 250 VAC, 50/60 HZ STD INRUSH, SHORT
DELAY, CURVE 3
CB2 260-5071-010 CIRCUIT BREAKER: 3 POLE, 15 AMP, 240 VAC, 50/60 HZ HIGH INRUSH, LONG
DELAY, CURVE 10
CB3 260-4011-320 CIRCUIT BREAKER: 3 POLE, 10 AMP, 240 VAC, 50/60 HZ NORM INRUSH,
MEDIUM DELAY, CURVE 2
CB4 260-5076-010 CIRCUIT BREAKER: 3 POLE, 15 AMP, 240 VAC, 50/60 HZ NORM INRUSH,
MEDIUM DELAY, CURVE 2
CB5 260-5074-010 CIRCUIT BREAKER: 3 POLE, 70 AMP, 480 VAC, 50/60 HA NORM INRUSH,
SHORT DELAY, CURVE 3
CB6 260-4060-080 CIRCUIT BREAKER: 3 POLE, 150 AMP, CURVE 1, SERIES TRIP MAGNETIC,
PRESSURE TERMINALS
Fl 264-0912-330 FUSE, CARTRIDGE: 250 VOLT, 10 AMP, SMALL, CERAMIC TUBE
F2 264-0009-000 FUSE, CARTRIDGE: 3 AMPS, 250V, GLASS
F3 264-0912-330 FUSE, CARTRIDGE: 250 VOLT, 10 AMP, SMALL, CERAMIC TUBE
F4 264-0291-000 FUSE, CARTRIDGE: 1/4AMP, 250V, SLO-BLO TYPE, GLASS 1/4" X 1-1/4", DUAL
ELEMENT TIME DELAY, HIGH INRUSH
F5 264-0291-000 FUSE, CARTRIDGE: 1/4AMP, 250V, SLO-BLO TYPE, GLASS 1/4" X 1-1/4", DUAL
ELEMENT TIME DELAY, HIGH INRUSH
F6 264-0295-000 FUSE, CARTRIDGE: 1 AMP, 250 VOLT, HIGH TIME LAG
F7 264-0008-000 FUSE, CARTRIDGE: 2 AMPS, 250V, GLASS
F8 264-0295-000 FUSE, CARTRIDGE: 1 AMP, 250 VOLT, HIGH TIME LAG
F9 264-0008-000 FUSE, CARTRIDGE: 2 AMPS, 250V, GLASS
FlO 264-0295-000 FUSE, CARTRIDGE: 1 AMP, 250 VOLT, HIGH TIME LAG
F11 264-0009-000 FUSE, CARTRIDGE: 3 AMPS, 250V, GLASS
F12 264-0008-000 FUSE, CARTRIDGE: 2 AMPS, 250V, GLASS
F13 264-0008-000 FUSE, CARTRIDGE: 2 AMPS, 250V, GLASS
F14 264-0008-000 FUSE, CARTRIDGE: 2 AMPS, 250V, GLASS
XFl 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF2 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF3 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF4 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF5 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF6 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF7 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF8 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF9 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF10 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XFll 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON

Change 4 6-67
PARTS LISTS 816R-2C

PL180303-1 CIRCUIT BREAKER ASSEMBLY - Continued Rev.-

Ref. Des. Part No. Description

XF12 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF13 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON
XF14 265-1241-090 FUSEHOLDER: LAMP EXTRACTOR, POST TYPE, 1-1/4" X 1/4" FUSE, 90-250
VOLT, BLACK, 470K OHMS, KNOB CLEAR, NEON

6-68 Change 4
816R-2C PARTS LISTS

(This Page Intentionall Left Blank)

Change 4 6-69
PARTS LISTS 816R-2C

12 23

22

21

16 L--~-- 11

-------7 (COIL ASSY-NO.3)


25 (4 PLACES)

10
14

4 9

.... 17
15 .... ........

81
2
20
....
';============:=:::::::::::s:;=====--I ........
13 ............ 3
.........
93G0331 .....
...... T81

18

Figure 6-21. Low Pass Filter Assembly, A7.

6-70 Change 4
816R-2C PARTS LISTS

PL786-3451-003 ASSEIVIBLY, LOW PASS FILTER Rev.F

Ref. Des. Part No. Description

2 172139-1 COVER,LP FILTER


3 172170-1 FILTER,BLOWER TNTAKE
4 *172171-1 BOX,LP FILTER
5 *786-3367-001 COIL ASSY-NO 1
6 *786-3369-001 COIL ASSY-NO 2
7 *786-3371-001 COIL ASSY-NO 3
8 786-3372-001 CAPACITOR-NO 1: ALUMINUM,6061-T651,1 THICK
9 786-3373-001 CAPACITOR-NO 2: ALUMINUM,6061-T6 ROD,6.500 DIA
10 786-3374-001 CAPACITOR-NO 3: ALUMINUM,6061-T6 ROD,6.500 DIA
11 786-3375-001 CAPACITOR-NO 4: ALUMINUM,6061-T6 ROD,6.500 DIA
12 *786-3379-001 RECEPTACLE,BULLET
13 786-3388-001 SPACER-NO l:TEFLON,I.OOO OD X 0.750 ill TUBE 1.663 INCH
14 786-3388-002 SPACER-NO 2:TEFLON,1.000 OD X 0.750 ill TUBE 3.125 INCH
15 786-3388-003 SPACER-NO 3:TEFLON,I.000 OD X 0.750 ID TUBE 2.725 INCH
16 786-3388-004 SPACER-NO 4:TEFLON,1.000 OD X 0.750 ID TUBE 3.025 INCH
17 786-3435-001 ROD,CAPACITOR:SILICON GSG-7,0.750 OD X 1/8 WALL
18 786-3437-001 PLATE,BASE:ALUMINUM,6061-T6,0.75 THICK
19 *786-3443-001 INLET
20 *786-3445-002 CONDUCTOR,OUTER
21 *786-3448-001 CAPACITOR NO.5
22 786-3449-001 SUPPORT,INNER CONDUCTOR-TV 1 FILTER: 1/2 THICK, TYPE GEE-7,
FIBERGLASS
23 786-3468-001 FLANGE,TVI FILTER:ALUMINUM,606i-T6,0.500 THICK
24 786-3469-001 INSULATOR DISC:TEFLON SH,0.250 THICK
25 786-3535-001 SPACER,CAPACITOR:1/2 DIA ROD,TEFLON PLASTIC
B1 009-5014-010 FAN,CENTRIFUGAL:148 CFM FREE AIR,3160 RPM FREE AIR 1 PHASE,115 VAC,
50160 HZ,DIRECT DRIVE
SI 267-5023-010 SWITCH,THERMOSTATIC:BI-METALLIC,SNAP ACTION, 175DEG F,OPEN ON
TEMP RISE,15DEG F DIFF,15AMP/120VAC CONT
TB1 367-0908-000 TERMINAL BOARD:2 TERMINALS,20 AMPS,3000V RMS, #6-32 X 1/4 BRASS,NP
SCREWS,16-14 AWG,PHENOLIC

Change 6 6-71
PARTS LISTS 816R-2C

@@@ TB1

GND @@@ E6 P1 A1
3 2 1

~
.. K3
~

~~O~
bOx 0
K6

DO K7
K4

K5

R3

R2
o
R1

CR3

93G0332
A2 K2A K2B K1A
K1B

Figure 6-22. Component Panel Assembly, AS.

6-72 Change 4
816R-2C PARTS LISTS

PL180320-1 COMPONENT PANEL ASSEMBLY Rev.E

Ref. Des. Part No. Description


Al *640-3466-001 CCA,POWER FAILURE RECYCLE
A2 *648-8104-001 VARIAC DRIVER ASSY
CR1 353-2607-000 SEMICONDlJCTOR DEVICE,DIODE:SIIJCON GLASS DIODE
CR2 353-2607-000 SEMICONDUCTOR DEVICE,DIODE:SILICON GLASS DIODE
CR3 353-3718-040 SEMICONDUCTOR DEVICE,DIODE:HIGH CURRENT
CR4 353-2607-000 SEMICONDUCTOR DEVICE,DIODE:SILICON GLASS DIODE
CR5 353-2607-000 SEMICONDUCTOR DEVICE,DIODE:SILICON GLASS DIODE
CR6 353-2607-000 SEMICONDUCTOR DEVICE,DIODE:SILICON GLASS DIODE
CR7 353-2607-000 SEMICONDUCTOR DEVICE,DIODE:SILICON GLASS DIODE
CR8 353-6442-070 SEMICONDUCTOR DEVICE,DIODE:SILICON,IAMP,1000V PRY DO-41 EPOXY
PKG,AXIAL LEADS (IN4007)
El 306-0234-000 POST,ELECTRICALIMECHANICAL EQUIPMENT:4-40 THREADS, 0.625
LENGTH,6500 VOLTS AC-RMS
E2 306-0234-000 POST,ELECTRICALIMECHANICAL EQUIPMENT:4-40 THREADS, 0.625
LENGTH,6500 VOLTS AC-RMS
E3 306-0234-000 POST,ELECTRICALIMECHANICAL EQUIPMENT:4-40 THREADS, 0.625
LENGTH,6500 VOLTS AC-RMS
E4 306-0234-000 POST,ELECTRICALIMECHANICAL EQUIPMENT:4-40 THREADS, 0.625
LENGTH,6500 VOLTS AC-RMS
E5 304-7015-010 TERMINAL LUG:SINGLE CABLE,#14 SOLID-1/0 STRANDED
J1 372-9717-010 CONNECTOR,RECEPTACLE,ELECTRICAL: 10 CONTACTS,DOUBLE
ROW,EDGEBOARD,SINGLE READOUT,.200 ROW,EYELET
KIA 410-6144-010 RELAY,ELECTROMAGNETIC:4P,NO,10 AMP,17 VOLT CONTACT 24 VDC COIL
KIB 410-6144-020 RELAY,ELECTROMAGNETIC:AUXILIARY CONTACT,2 POLES, 1 NO,l NC,6
AMP,17 VOLT CONTACT,24 VDC COIL
K2A 41 0-6216-010 RELAY,ELECTROMAGNETIC:DPDT,30AMP@277VAC CONTACTS 24VDC
COIL,PANEL MT,PLASTIC DUST COVER
K2B 401-5040-020 CONTACTOR,MAGNETIC:4P-NO,CONTACTS RATED 30A@600VAC
COIL-220VAC,50HZ,OPEN STYLE,PRESSURE CONTACTS
K3 970-0007-180 RELAY,ELECTROMAGNETIC:3PDT,5AMP@28VDC/240VAC CONT 24VDC
COIL,PLAIN PLASTIC CASE,SOCKET MOUNT
K4 410-6173-010 TIMER,SEQUENTIAL:PROGRAMMABLE,8 FUNCTIONS, 24-240V AC/DC
INPUT,O.1 SEC TO 100 MIN RANGE
K5 403-0038-010 RELAY,ELECTROMAGNETIC:PHASE MONITOR, LOW VOLTAGEIPHASE
REVERSAL
K6 970-0007-180 RELAY,ELECTROMAGNETIC:3PDT,5AMP@28VDC/240VAC CaNT 24VDC
COIL,PLAIN PLASTIC CASE,SOCKET MOUNT
K7 970-0007-180 RELAY,ELECTROMAGNETIC:3PDT,5AMP@28VDC/240VAC CONT 24VDC
COIL,PLAIN PLASTIC CASE,SOCKET MOUNT
R1 724-5055-360 RESISTOR,FIXED,FILM:820 OHM,+-5%,2 WATT @ 70C METAL
FILM,TC=250PPMIDEGC,COLOR BANDED
R2 724-5055-360 RESISTOR,FIXED,FILM:820 OHM,+-5%,2 WATT @ 70C METAL
FILM,TC=250PPMIDEGC,COLOR BANDED
R3 710-5076-050 RESISTOR,FIXED,WlRE WOUND:O.5 OHMS,+-10%,100 WATT
TB1 367-5600-010 TERMINAL BLOCK,ELECTRICAL:3 POLE,600 VOLT,31 0 AMPS PER POLE
XK3 220-0010-010 SOCKET,RELAY:CHASSIS MTD FOR WIRED ASSEMBLY
XK4 220-6036-080 SOCKET,PLUG-IN ELECTRONIC COMPONENT:ll CONTACT,STD 11 PIN TUBE
SKT,PHENOLIC,W/GROUND LUGS,W/O SHIELD
XK5 220-6036-060 SOCKET,PLUG-IN ELECTRONIC COMPONENT:8 CONTACT,STD OCTAL TUBE
SKT,PHENOLIC,W/GROUND LUGS,W/O SHIELD
XK6 220-0010-010 SOCKET,RELAY:CHASSIS MTD FOR WIRED ASSE~IBLY
XK7 220-0010-010 SOCKET,RELAY:CHASSIS MTD FOR WIRED ASSEMBLY

Change 5 6-73
PARTS LISTS 816R-2C

~
G-i R3 K>
G-i R5 K>
~+
~ ~f
C2

C1

!~ ~~2
+

w
E~
01g
~
..--
~
..--
~
6
i

XK2 XK1 C3
K2 K1
+

93G0333

Figure 6-23. Power Failure Recycle Circuit Card Assembly, A8At.

6-74 Change 4
816R-2C PARTS LISTS

PL640-3466-001 CCA, POWER FAILURE RECYCLE Rev.B

Ref. Des. Part No. Description

Cl 184-6330-360 CAPACITOR, FIXED, ELECTROLYTIC: 68 MicroF, ±200/0, 40 WVDC


C2 183-1281-080 CAPACITOR, FIXED, ELECTROLYTIC: 100 MicroF, +85-10%, 50WVDC
ALUMINUM, INSULATED, AXIAL LEADS, .385" D, 1.536" L
C3 183-1278-180 CAPACITOR, FIXED, ELECTROLYTIC: 5500 MicroF, +100-100/0, 40 WVDC,
ALUMINUM DIELECTRIC
CRl 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR2 353 -6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR3 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR4 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR5 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR6 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
K1 970-0002-030 RELAY, ELECTROMAGNETIC: 4PDT, 3AMP, 30VDC CONTACT RTG 24VDC
COIL, PLASTIC ENCLOSURE, SOLDER TERMS
K2 970-0002-030 RELAY, ELECTROMAGNETIC: 4PDT, 3AMP, 30VDC CONTACT RTG 24VDC
COIL, PLASTIC ENCLOSURE, SOLDER TERMS
Q1 352-1104-010 TRANSISTOR: NPN, SILICON, 4AMP, 100V, 1.5 WATT DISS PLASTIC PKG,
CHASSIS MT, (MJE243)
Q2 352-1104-010 TRANSISTOR: NPN, SILICON, 4AMP, 100V, 1.5 WATT DISS PLASTIC PKG,
CHASSIS MT, (MJE243)
Rl 724-5053-240 RESISTOR, FIXED, FILM: 2210HM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R2 724-5053-800 RESISTOR, FIXED, FILM: 100KOHM, ±1 0/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R3 724-5053-440 RESICTOR, FIXED, FILM: 22100HM, ± 1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R4 724-5053-440 RESICTOR, FIXED, FILM: 22100HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R5 724-5053-440 RESICTOR, FIXED, FILM: 22100HM, ±1%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R6 724-5053-600 RESISTOR, FIXED, FILM: 10KOHM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R7 724-5053-440 RESICTOR, FIXED, FILM: 22100HM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R8 724-5053-440 RESICTOR, FIXED, FILM: 22100HM, ±l%, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
VR1 353-6481-160 SEMICONDUCTOR DEVICE, DIODE: SILICON, 1 WATT, 6.2 VOLT
VR2 353-0221-360 SEMICONDUCTOR DEVICE, DIODE: TRANSIENT SUPPRESSOR, 34.2-37.8
VOLTAGE BREAKDOWN
VR3 353-0221-360 SEMICONDUCTOR DEVICE, DIODE: TRANSIENT SUPPRESSOR, 34.2-37.8
VOLTAGE BREAKDOWN
XKl 220-1582-010 SOCKET,RELAY: 14CONTACT
XK2 220-1582-010 SOCKET,RELAY: 14CONTACT

Change 4 6-75
PARTS LISTS 816R-2C

* (FURNISHED WITH 81) CEC # 933-5053-010

81 E1 C1 T81

S1

* C4

S2 E2 C3 C2

Figure 6-24. Variac Driver Assembly, A8A2.

6-76 Change 4
816R-2C PARTS LISTS

PL648-8104-001 VARIAC DRIVER ASSEMBLY Rev.D

Ref. Des. Part No. Description

Bl 230-0581-010 MOTOR, ALTERNATING CURRENT: 1RPM OUT, 1000Z-IN TORQUE


115V-60HZ-IPH, REVERSIBLE, W/CLUTCH, BRAKE AND CAPACITOR
Cl 913-3152-000 CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, +80 -20%,500 WVDC DISC TYPE,
Z5U TEMP COEFFICIENT
C2 913-3152-000 CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, +80 -20%,500 WVDC DISC TYPE,
Z5U TEMP COEFFICIENT
C3 913-3152-000 CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, +80 -20%, 500 WVDC DISC TYPE,
Z5U TEMP COEFFICIENT
E1 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
E2 306-0234-000 POST, ELECTRICAL/MECHANICAL EQUIPMENT: 4-40 THREADS, 0.625
LENGTH, 6500 VOLTS AC-RMS
Sl 260-2293-000 SWITCH, SENSITIVE: SUBMINIATURE, SPDT
S2 260-2293-000 SWITCH, SENSITIVE: SUBMINIATURE, SPDT
T1 664-4010-020 TRANSFORMER, POWER: VARIABLE, INPUT=240V, 50/60HZ, IPH
OUTPUT=0-280V, 7.5AMP, 2.1KVA, MANUAL, OPEN FRAME
TB1 367-0914-000 TERMINAL, BOARD: 8 TERMINALS, 20 AMP, 3000 VRMS, #6-32 X 1/4 BRASS,
NP SCREWS, 16-14 AWG, PHENOLIC

Change 4 6-77
PARTS LISTS 816R-2C

AC1 L1 AC2 L2 AC3 L3


05 (REF)

o o

01 (REF)
03 (REF)
Z1A Z1B Z1C
04 (REF)

02 (REF)

o o
L4 L5 L6
06 (REF)

95G0098

Figure 6-25. SCR Assembly, A9.

6-78 Change 4
816R-2C PARTS LISTS

PL180304-1 SCR ASSEMBLY Rev. -

Ref. Des. Part No. Description

ZIA 353-6551-010 SEMICONDUCTOR DEVICE, SCR ASSEMBLY: 3 PHASE, FULL-WAVE


RECTIFIER
ZIB 353-6551-010 SEMICONDUCTOR DEVICE, SCRASSEMBLY: 3 PHASE, FULL-WAVE
RECTIFIER
ZIC 353-6551-010 SEMICONDUCTOR DEVICE, SCR ASSEMBLY: 3 PHASE, FULL-WAVE
RECTIFIER

Change 4 6-79
PARTS LISTS 816R-2C

(BACK SIDE)
T1 A2 A1 R2 R1

C1

I
t
t
o I
t
I
I
I
I

,,
I

,,
,
I
I
o : 0
--- - - - ---- -- -------- -- --- ---_.!

.------.
I
I
I
I
o
I I
I I
I I
I I
I I
I
I
I
I PS1
I I

r=-____.@ DO D~
o

OOG0006

TB2 TB1
(BACK SIDE) (BACK SIDE)

Figure 6-26. Power Supply Assembly, AIO.

6-80 Change 4
816R-2C PARTS LISTS

PL180318-1 POWER SUPPLY ASSEMBLY Rev.H

Ref. Des. Part No. Description

Al *180383-1 CCA, BIAS COMPONENT


A2 *180310-3 CCA, REMOTE CONTROL
C1 930-0038-000 CAPACITOR, FIXED, PAPER: 10 MicroF, ±10%, 1000 WVDC
PSI 270-3177-010 POWER SUPPLY: DC, 1 OUTPUT, 28V, 7 AMP@50C, 200 WATT 207-250V,
50-420HZ IN, LINEAR, REG=.Ol% LINE, .1% LOAD
R1 746-6172-000 RESISTOR, FIXED, WIREWOUND: 10K OHM, ±5%, 12 WATT
R2 747-1686-000 RESISTOR, FIXED, WIRE WOUND: 1000 OHMS, ±5%, 26 WATT
T1 662-0218-010 TRANSFORMER, POWER: STEP-UP, 208-230 VRMS/300 VOLT
TB1 367-0924-000 TERMINAL BOARD: 18 TERMINALS, 20 AMP, 3000 VRMS, #6-32 X 1/4 BRASS,
NP SCREWS, 16-14 AWG, PHENOLIC
TB2 367-0924-000 TERMINAL BOARD: 18 TERMINALS, 20 AMP, 3000 VRMS, #6-32 X 1/4 BRASS,
NP SCREWS, 16-14 AWG, PHENOLIC

Change 4 6-81
PARTS LISTS 816R-2C

('CO
I

:
:
I
I
I
I
I
I
I
1
---

:
00
-.@$8 Gl
6~UQ~
~~
I
I
I
I
I
I
I
.1

0
~
ITIIIO].""
~

:0
r--
I

.I
I
I
o

M ,...
a: a:
u u
M
a:

0
,... ,....
u a:
It)
a:
~ C\I u
a: a:
u u

TB1
1 8
93G0337

Figure 6-27. Bias Component Circuit Card Assembly, AIOA1 .

6-82 Change 4
816R-2C PARTS LISTS

PL180383-1 CCA, BIAS COMPONENT Rev. A

Ref. Des. Part No. Description

C1 931-8592-000 CAPACITOR, FIXED, PAPER DIELECTRlC: 0.047 MicroF, ±20%, 600 WVDC
CR1 353-6467-050 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PIV GLASS PKG,
HERMETICALLY SEALED, AXIAL LEADS (lN4586)
CR2 353-6467-050 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PIV GLASS PKG,
HERMETICALLY SEALED, AXIAL LEADS (lN4586)
CR3 353-6467-050 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PIV GLASS PKG,
HERMETICALLY SEALED, AXIAL LEADS (lN4586)
CR4 353-6467-050 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PIV GLASS PKG,
HERMETICALLY SEALED, AXIAL LEADS (lN4586)
CR5 353-6467-050 SE:NIICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PIV GLASS PKG,
HERMETICALLY SEALED, AXIAL LEADS (lN4586)
R1 724-5054-310 RESISTOR, FIXED, FILM: 330 OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R3 705-4254-000 RESISTOR, FIXED, FILM: 1 MEGOHM, ±l%, 3 WATT
R4 377-5034-010 RESISTOR, VARlABLE, WIRE WOUND: 2000 OHM, ±5%, 1 WATT SINGLE
TURN, 310 DEG, PC PINS, TOP ADJ
TB1 306-3051-010 TERMINAL BOARD: 8 POLES, 2 PINS/POLE, 0.2" PITCH 26-14 AWG WIRE SIZE,
PWB MOUNTING, BLUE, 300V, lOA RTG

Change 4 6-83
PARTS LISTS 816R-2C

o.Co---- _.@~ rJ rJ n
:
:
I
I
I
:
I
I
0

1_- _ :
00
®~~~O@0
I
I
I
I

I
I
,lIIIITIl:"'
:0
r--

I 12
TB1

K1,
XK1
¢5 K2
XK2

l 1 C1c:=J C2 c:=J
10 G D
6
~
20
C0

Qg
0
co
K3 K4
~

XK3 >-
en
XK4
en
<{
J1 ~ J2
lO
~

N
C4 c:=J C5 c:=J lO

Qg
~
K5 K6
XK5 XK6
20
J
C6c:=J C7 c:=J

K7
XK7 ¢¢B -.:::t
0:::
K8
XK8

0
1
C8 c:=J C9 c:=J

93G0338

Figure 6-28. Remote Control Circuit Card Assembly, AIOA2.

6-84 Change 4
816R-2C PARTS LISTS

PL180310-3 CCA, REMOTE CONTROL Rev. A

Ref. Des. Part No. Description

C1 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC


C2 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C3 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C4 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C5 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C6 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C7 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C8 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
C9 CK06BX104K CAPACITOR, FIXED, CERAMIC: 0.1 MicroF, ±10%, 100 WVDC
CR1 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR2 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
CR3 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
CR4 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-41 EPOXY
PKG, AXIAL LEADS (lN4007)
CR5 353-6442-070 SEMICONDUCTOR DEVICE, DIODE: SILICON, lAMP, 1000V PRY DO-4l EPOXY
PKG, AXIAL LEADS (lN4007)
J1 372-9765-020 CONNECTOR, RECEPTACLE, ELECTRICAL: 20 POSITIONS SINGLE ROW,
SHROUDED HEADER, SQ STRAIGHT POST
J2 372-9765-020 CONNECTOR, RECEPTACLE, ELECTRICAL: 20 POSITIONS SINGLE ROW,
SHROUDED HEADER, SQ STRAIGHT POST
K1 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K2 410-6109-030 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, DUAL COIL LATCH, PLSTC ENCL, SEALED, DIL
K3 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K4 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K5 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K6 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K7 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
K8 410-6098-010 RELAY, ELECTROMAGNETIC: DPDT, 2AMP@28VDC CONTACT RTG 24VDC
COIL, PLSTC ENCL, SEALED, PWB MT
R1 RCR20G330JS RESISTOR, FIXED, COMPOSITION: 33 OHMS, ±5%, 1/2 WATT
R2 RCR20G330JS RESISTOR, FIXED, COMPOSITION: 33 OHMS, ±5%, 1/2 WATT
TB1 367-5566-110 TERMINAL BOARD: 12 POSITIONS, 20 AMPS, 300 VOLTS, #3-48 UNC, 12-22
AWG
XKl 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK2 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK3 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK4 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK5 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK6 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK7 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS
XK8 220-0049-020 SOCKET, INTEGRATED CIRCUIT: DUAL IN-LINE, 16 POSTS

Change 4 6-85
PARTS LISTS 816R-2C

(This Page Intentionally Left Blank)

6-86 Change 4
816R-2C PARTS LISTS

52
S15
C92

C48

C84
C85
TUBE
S7
CHIMNEY

P4, J4
P5, J5

~ 786-3029-002
786-3029-001 FINGER
FINGER CONTACT CONTACT

SLIDER
DECK
FINGER STOCK
180028-(4PCS)

BLOCKING
PA CAPACITOR
TUNING C2 (REF)
(C51)

/786-3029-001
786-3029-002 FINGER
FINGER CONTACT CONTACT

R75
PA LOADING
(C50)

TUBE

TUBE
SHELF

A3

786-3032-001
C82
FINGER
CONTACT
C83

03G103

S6

Figure 6-29. PA Cavity Assembly (Front View), A12. (Sheet 1 of 2)

Change 5 6-87
PARTS LISTS 816R-2C

C41 (CEC # 933-5053-010 C42 (CEC # 933-5053-010


A2 A1 FURNISHED WITH 83) FURNISHED WITH 82)
,,
,,:

t
,/ "
,

,./
t

caa
,: 0

83 .... ,,
,,
,
" C90/91
..........
.... ,," 0

..........
"
,,
S13
,,
...... o
..............
............
"
,,
o

82
o
514
512
o o o o
C86
511 R36
"
I~ I I~ I
C87,,"'" @] @]

C89 ........ T1
o E> E> E> ...........

r------.-
.....-......-....- .I ••••••••••••••••••••••••••••••
C32
o

C54
®
R35 o

C55

C56

93G0341
(REAR VIEW)

Figure 6-29. PA Cavity Assembly (Rear Vie)v), A12. (Sheet 2 of 2)

6-88 Change 4
816R-2C PARTS LISTS

PL786-3335-005 POWER AMPLIFIER CAVITY ASSEMBLY Rev. AR

Ref. Des. Part No. Description

Al 643-7445-001 CCA,METERING MULTIPLIER


A2 643-7446-001 CCA,METERING MULTIPLIER
A3 786-3686-002 SOCKET ASSEMBLY,ELECTRON TUBE
B2 230-0581-010 MOTOR,ALTERNATING CURRENT: 1RPM OUT,1000Z-IN TORQUE 115V-60HZ-
1PH,REVERSIBLE,W/CLUTCH,BRAKE&CAPACITOR
B3 230-0581-010 MOTOR,ALTERNATING CURRENT: 1RPM OUT,1000Z-IN TORQUE 115V-60HZ-
IPH,REVERSIBLE,W/CLUTCH,BRAKE&CAPACITOR
C1 922-8011-010 CAPACITOR,VARIABLE,AIR:5.5-10.2 PF,3 PLATES,
C2 180322-1 CAPACITOR MODIFICATION
C32 241-1031-010 FILTER,RADIO FREQUENCY INTERFERENCE:1500PF MIN 2500WVDC,PI TYPE
FEEDTHRU,W-3/8-32 MTG HARDWARE
C40 913-0845-000 CAPACITOR,FIXED,CERAMIC:31 OPF,+-50/0,2500WVDC TRANSMITTING TYPE,
6-32 THD TERM,1.8AMP@lMHZ
C46 930-0038-000 CAPACITOR,FIXED,PAPER:10 UF,+-10 0;O,1000 \VVDC
C48 913-7150-010 CAPACITOR,FIXED,CERAMIC:500 PF,+80-200/0,20K WVDC WITHOUT ADAPTER
C49 913-7150-010 CAPACITOR,FIXED,CERAMIC:500 PF,+80-200/0,20K WVDC WITHOUT ADAPTER
C52 913-5113-050 CAPACITOR,FIXED,CERAMIC: 100 PF,+-l 00/0, 15K WVDC
C54 241-1031-010 FILTER,RADIO FREQUENCY INTERFERENCE:1500PF ~1IN 2500WVDC,PI TYPE
FEEDTHRU,W-3/8-32 MTG HARDWARE
C55 241-0090-000 CAPACITOR,FIXED,PAPER:O.l UF,+-10%,600 WVDC
C56 241-0090-000 CAPACITOR,FIXED,PAPER:0.1 UF,+-100/0,600 WVDC
C82 CK70AWI 02M CAPACITOR,FIXED,CERAMIC: 1000 PF,+-20%,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
C83 CK70AWI 02M CAPACITOR,FIXED,CERAMIC: 1000 PF,+-20%,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
C84 CK70AWI 02M CAPACITOR,FIXED,CERAMIC: 1000 PF,+-200/0,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
C85 CK70AWI 02M CAPACITOR,FIXED,CERAMIC: 1000 PF,+-200/0,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
C86 913-3152-000 CAPACITOR,FIXED,CERAMIC:O.1 UF,+80 -20%,500 \VVDC DISC TYPE,Z5U TEMP
COEFFICIENT
C87 913-3152-000 CAPACITOR,FIXED,CERAMIC:0.1 UF,+80 -200/0,500 WVDC DISC TYPE,Z5U TEMP
COEFFICIENT
C88 913-3152-000 CAPACITOR,FIXED,CERAMIC:0.1 UF,+80 -20%,500 WVDC DISC TYPE,Z5U TEMP
COEFFICIENT
C89 913-3152-000 CAPACITOR,FIXED,CERAMIC:O.l UF,+80 -200/0,500 WVDC DISC TYPE,Z5U TE11P
COEFFICIENT
C90 913-3152-000 CAPACITOR,FIXED,CERAMIC:O.l UF,+80 -20%,500 WVDC DISC TYPE,Z5U TEMP
COEFFICIENT
C91 913-3152-000 CAPACITOR,FIXED,CERAMIC:O.l UF,+80 -200/0,500 WVDC DISC TYPE,Z5U TEMP
COEFFICIENT
C92 CK70AWI 02M CAPACITOR,FIXED,CERAMIC: 1000 PF,+-20%,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
C93 CK70AW102M CAPACITOR,FIXED,CERAMIC:IOOO PF,+-20%,500 WVDC FEEDTHRU TYPE,WIRE
LEADS
J1 M39012/04-0002 CONNECTOR,RECEPTACLE,ELECTRICAL:SERIES N, TEFLON
DIELECTRIC,PANEL MOUNT
12 M39012/19-0101 CONNECTOR,RECEPTACLE,ELECTRICAL:BNC BULKHEAD TYPE (TYPE
UG909/U)
J4 M39012/21-0001 CONNECTOR,RECEPTACLE,ELECTRICAL:BNC,FEMALE JAM NUT MOUNTED
(OLD UG-625B/U)
J5 M390 12/21-0001 CONNECTOR,RECEPTACLE,ELECTRICAL:BNC,FEMALE JAM NUT MOUNTED
(OLD UG-625B/U)

Change 6 6-89
PARTS LISTS 816R-2C

PL786-3335-005 POWER AlVIPLIFIER CAVITYASSEMBLY - Continued Rev. AR

Ref. Des. Part No. Description

J6 M39012/19-0101 CONNECTOR,RECEPTACLE,ELECTRICAL:BNC BULKHEAD TYPE (TYPE


UG909/U)
L5 MS91189-21 COIL,RADIO FREQUENCY:4.7 UH,+-10%,860 DCMA,Q=60MIN 90 MHZ SELF
RESONANT FREQ,0.560 DCR MAX
L6 786-3548-001 CHOKERF
P4 M39012/16-0101 CONNECTOR,PLUG,ELECTRICAL:BNC,COAXIAL,PIN CONTACT (TYPE UG-
88E/U)
P5 M39012/I6-0101 CONNECTOR,PLUG,ELECTRICAL:BNC,COAXIAL,PIN CONTACT (TYPE UG-
88E/U)
RI 745-8013-010 RESISTOR,FIXED,COMPOSITION:50 OHMS,+-20%,100 WATT @40 DEG C,4KV
PEAK,NON-INDUCTIVE,l "OD,6"LONG
R35 749-1028-000 RESISTOR,VARlABLE,WIRE WOUND:2500 OHM,+-10,50 WATT 0.14 MAX
AMPERES,7/8" LONG SHAFT,SLOTfED
R36 710-9294-000 RESISTOR,FIXED,WIRE WOUND:3000 OHM,+-5%,100 WATT VITREOUS
ENAMEL COATING,RADIAL LUG TERMINALS
R55 RCR42G220JS RESISTOR,FIXED,COMPOSITION:22 OHMS,+-5%,2 WATTS
R75 712-0070-000 RESISTOR,FIXED,COMPOSITION:50 OHMS,+-20%,60 WATT
Sl 266-9960-010 SWITCH,FLOW:SPDT AIR SWITCH ADJUSTABLE FROM 0.05" TO 12" WC
S6 627-9743-004 SWITCH ASSEMBLY,SHORTING
S7 627-9743-004 SWITCH ASSEMBLY,SHORTING
SI1 266-3081-000 SWlTCH,SENSITIVE:SINGLE POLE,DOUBLE THROW SNAP SOLDER LUG
TERMINAL,MAX OPER FORCE,6
S12 266-3081-000 SWlTCH,SENSITIVE:SINGLE POLE,DOUBLE THROW SNAP SOLDER LUG
TERMINAL,MAX OPER FORCE,6
S13 266-3081-000 SWITCH,SENSITIVE:SINGLE POLE,DOUBLE THROW SNAP SOLDER LUG
TERMINAL,MAX OPER FORCE,6
S14 266-3081-000 SWlTCH,SENSITIVE:SINGLE POLE,DOUBLE THROW SNAP SOLDER LUG
TERMINAL,:lvIAX OPER FORCE,6
SI5 267-5023-020 SWITCH,THERMOSTATIC:BI-METALLIC,SNAP ACTION 224/256DEG
F,NC,30DEG DIFF,15AMP/120VAC CON
T1 662-0410-020 TRANSFORMER,POWER:STEP-DOWN,208 VRMS/7.5 VRMS

6-90 Change 6
816R-2C PARTS LISTS

(This Page Intentionally Left Blank)

Change 4 6-91
PARTS LISTS 816R-2C

12

R3
R4
R5
R6
R7
R8
R9
R10
811
R12
R13
R14
R15
R16

R17
R18
I R19
R20

R21
R22
R23
R24

C1 38

37 VR1
1----...,.-- R27
C2
43 R29
VR3
45

93G0342

Figure 6-30. Metering Multiplier Circuit Card Assembly, A12Al.

6-92 Change 4
816R-2C PARTS LISTS

PL643-7445-001 CCA, METERING MULTIPLIER Rev.C

Ref. Des. Part No. Description

C1 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±20%, 500 WVDC


C2 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±200/0, 500 WVDC
R1 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
R2 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R3 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
R4 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R5 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
R6 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R7 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R8 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
R9 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
RIO 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1 0/0,3 WATT
R11 705-1493-020 RESISTOR, FIXED, FILM: 750K OI-IMS, ±1 0/0,3 WATT
R12 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1 0/0,3 WATT
R13 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R14 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R15 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R16 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R17 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R18 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ± 10/0, 3 WATT
R19 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R20 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1%, 3 WATT
R21 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1 %,3 WATT
R22 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R23 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±1 0/0,3 WATT
R24 705-1493-020 RESISTOR, FIXED, FILM: 750K OHMS, ±10/0, 3 WATT
R27 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±50/0, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R29 724-5053-490 RESISTOR, FIXED, FILM: 51100HM, ±10/0, 1/2WATT@70C METAL FILM,
TC=100PPM/DEGC, COLOR BANDED
R30 705-4254-000 RESISTOR, FIXED, FILM: 1 MEGOHM, ±1 0/0, 3 WATT
R31 705-4254-000 RESISTOR, FIXED, FILM: 1 MEGOHM, ± 1%, 3 WATT
VR1 353-1339-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 100V, ±50/0, 1 WATT METAL
CASE, AXIAL LEADS
VR3 353-1339-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 100V, ±50/0, 1 WATT METAL
CASE, AXIAL LEADS

Change 4 6-93
PARTS LISTS 816R-2C

VR1

C1
R27

R32

C2 VR3

o
93G0343

Figure 6-310 Metering Multiplier Circuit Card Assembly, A12A20

6-94 Change 4
816R-2C PARTS LISTS

PL643-7446-001 CCA, METERING MULTIPLIER Rev.B

Ref. Des. Part No. Description

Cl CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±20%, 500 WVDC


C2 CK63AW103M CAPACITOR, FIXED, CERAMIC: 0.01 MicroF, ±20%, 500 WVDC
Rl 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R2 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R3 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R4 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R5 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R6 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R7 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R8 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R9 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
RIO 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
Rl1 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R12 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R13 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R14 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R15 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R16 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R17 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R18 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R19 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R20 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R21 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R22 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPMlDEGC, COLOR BANDED
R23 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED

Change 4 6-95
PARTS LISTS 816R-2C

PL643-7445-001 CCA, METERING MULTIPLIER - Continued Rev.B

Ref. Des. Part No. Description

R24 724-5055-640 RESISTOR, FIXED, FILM: 180K OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R27 724-5055-400 RESISTOR, FIXED, FILM: 1800 OHM, ±5%, 2 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
R32 724-5054-490 RESISTOR, FIXED, FILM: 10K OHM, ±5%, 1 WATT @ 70C METAL FILM,
TC=250PPM/DEGC, COLOR BANDED
VR1 353-1339-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 100V,±5%, 1 WATT METAL
CASE, AXIAL LEADS
VR3 353-3121-000 SEMICONDUCTOR DEVICE, DIODE: ZENER, 6.8V, ±5%, 1 WATT SILICON,
VOLTAGE REGULATOR, AXIAL LEADS

6-96 Change 4
816R-2C PARTS LISTS

(This Page Intentionally Left Blank)

Change 4 6-97
PARTS LISTS 816R-2C

NEUTRALIZATION CLAMPS (2)


CONSISTING OF CEC #786-3236-001 AND CEC #786-3237-001

C12 C11 L3* C10 C59 C13 A12C2 (REF) C9 C8

C7

C53

A12C1 (REF)
*A12C3 (REF)
A12J1 (REF)
A12L5 (REF)

A12R1 (REF)

C39
A12C40 (REF)

A 12R55 (REF)
CGO

XV1 FILAMENT
LEAD
A12T1 (REF) C38 C58 C4 *' L1 C5 CG
* MECHANICAL ASSEMBLIES
LIST OF REPLACEABLE PARTS OF XV1

C43 220-1500-000 FILAMENT BYPASS CAPACITOR (BUILT INTO TUBE SOCKET)


C44 SAME AS C43
220-1494-000 OUTER FILAMENT COLLET
220-1495-000 INNER FILAMENT COLLET
220-1497-000 INSULATOR POST (8 REQUIRED)
220-1496-000 CONTROL GRID COLLET
220-1498-000 INSULATOR SLEEVE (8 REQUIRED)
220-1500-000 SCREEN GRID COLLET
220-1502-000 INSULATOR WASHER, SPACER FOR SCREWS THAT GO
THRU FILAMENT COLLETS (14 REQUIRED)
220-1506-000 SCREEN COLLET SPRING
BRASS SCREWS (14 REQUIRED) 93G0344

Figure 6-32. PA Tube Socket Assembly, A12A3.

6-98 Change 4
816R-2C PARTS LISTS

PL786-3686-002 SOCKET ASSEMBLY, ELECTRON TUBE Rev.H

Ref. Des. Part No. Description

C4 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING


TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C5 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±100/0, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C6 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C7 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±100/0, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C8 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±100/0, 5000WVDC TRANSl\1ITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C9 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C10 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±100/0, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C11 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C12 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C13 913-5113-250 CAPACITOR, FIXED, CERAMIC: 500 PicaF, ±20%, 5000 WVDC
C38 913-7096-020 CAPACITOR, FIXED, CERAMIC: 1000PicaF, -20+400/0, 3500V PKWKG PLATE
CAPACITOR, CONTOURED RIM, CLASS 2 CERAMIC
C39 922-8010-010 CAPACITOR, VARIABLE, AIR: 8.5 TO 32 PicaF, 1 SECTION, 11 PLATES, 0.0715
INCH AIR GAP
C53 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±100/0, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C58 913-0821-000 CAPACITOR, FIXED, CERAMIC: 100PicaF, ±10%, 5000WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 1.8AMP@lMHZ
C59 913-0830-000 CAPACITOR, FIXED, CERAMIC: 75PicaF, ±5%, 3500WVDC TRANSMITTING
TYPE, 6-32 THD TERM, 2AMP@lMHZ
C60 913-5113-250 CAPACITOR, FIXED, CERAMIC: 500 PicaF, ±20%, 5000 WVDC
XVI 220-1491-000 SOCKET, ELECTRON TUBE: 4CX5000 AND 4CX15000

Change 4 6-99
PARTS LISTS 816R-2C

E1

R1

R3

R2 R4

o o
93G0345

Figure 6-33. Bleeder Resistor Assembly, A13.

6-100 Change 4
816R-2C PARTS LISTS

PL180394-1 BLEEDER RESISTOR ASSEMBLY Rev. -

Ref. Des. Part No. Description

El 013-1332-020 ARRESTER, LIGHTNING: 150-300 OPERATING VDC, GREEN


Rl 746-6662-000 RESISTOR, FIXED, WIRE WOUND: 18 OHMS, ±5%, 210 WATT SILICONE
COATED, 3/8"TAB TERM, TIN PLTD
R2 746-6737-000 RESISTOR, FIXED, WIRE WOUND: lOOK OHM, ±5%, 210 WATT SILICONE
COATED, 3/8" TAB TERM, TIN PLTD
R3 746-6737-000 RESISTOR, FIXED, WIRE WOUND: lOOK OHM, ±5%, 210 WATT SILICONE
COATED, 3/8" TAB TERM, TIN PLTD
R4 746-6817-000 RESISTOR, FIXED, WIRE WOUND: 5100 OHM, ±5%, 210 WATT SILICONE
COATED, 3/8" TAB TERM, TIN PLTD

Change 4 6-101
PARTS LISTS 816R-2C

(This Page Intentionally Left Blank)

6-102 Change 4
816R-2C DIAGRAMS

SECTION 7 - DIAGRAMS

7-1. INTRODUCTION

This section of the Operation and Maintenance manual Schematics are arranged in ascending reference designator
contains schematic diagrams for the 816R-2C, FM (Ref. Des.) number order. An index of schematics is
Transmitter. Drawings have been reduced from large format provided in Table 7-1, the table is in Ref. Des. order.
engineering drawings.

TABLE 7-1. Index of Schematic Diagrams

Schematic Ref. Page


No. Rev. Description Des. No.

*193794 C Transmitter 816R-2C I


*189579 B Status and Interlock Simplified Diagram

189667 B Control Panel AlAI 7-3

182902 Filament Regulator A2A4 7-7

180167 Overload/Recycle A2A5 7-9

180162 A Power Monitor/Control A2A6 7-11

189621 C Card Cage Components A2A7 7-13

180196 A Backplane A2A8 7-15

195125 IPA 816R A3 7-19 I


195080 E Metering Card Circuit Card Assembly A3Al 7-21

189626 IPA Status A3A2 7-23

189397 A Amplifier Module A3A3A1 - A2 7-25

189211 C Control Circuit Card Assembly A3A3A1-A2A1 7-27

189214 B RF Circuit Card Assembly A3A3A1-A2A2 7-29

194874 Remote Control A10A2 7-31 I

* Located in envelope at rear of manual.

Change 5 7-1
DIAGRAMS 816R-2C

(This Page Intentionally Left Blank)

7-2 Change 4
816R-2C DIAGRAMS

~ f P')
N
ID
I -<I
~
(Xl
ro-) J, I

~ ~ ~
~ ~-< ~ ~g
CD

~ ~
t') (>
en I
< :< ~
If.l-
en :<
f? ....0 0
.... ~ ~ ....0 ....0 g ~ ....0 g

IA1Rl IPAOCffiI ~ IiiITrUI I~~I


l.Jl!IhIS.J IN1U< ~ ~ VU~I"VL

>
(X)
(',I

to

fo
I
OVLD FAU. T
RESET
I >
l{)

>
<:D :>
N ID
SJ S2

r
I I
-ro-)
"')J

~
0-
0
....
i 777777
=)~=)~:;~

~
g
If)

i
2
0>f1>
ro-)P')
I
=)J
I

N
~

a>
~
~
2
P')'"

~)"
~
I
~
I
~
~
If)
I
a>

~o
TO AI2SIJ-C

TO AI2S11-C
UMIT INJICAT(R> C22
II1
rns
1..
IN4007 ~
R2
1.21<

, ~ TOAl2St3-N)

S'9 C23 CR7


.>4-19
I ....I2-J9 TO Al2S14-NO

I po~ I t 1N4007

_>-._ I ~TE I AOJ TO A6XF14-'2


;
C25
II
CR9
J4-38

LJ'v----"''-t-tiS5~/.!'_t_4-__,
....12-38 TO AI2S12-ID
IN4007
sa !i
C24 CRB

1.21K 1.21K t--I


i
::=~ :TO Al2S11-NJ
1 JN4007
m ~ ~
TO Al2E54 ~ ~ i I
TO AI2ES5

, TO AI2S14--C

TO Al2St2-C
0>
I
ro-)
~
'?
t--
I
..,
I
a>
P')
t "I
f1>
~
&

I
~ P')

~ g ~
0...
ii: Q: ii: G-
....o g ....0 ....0
g g g

t-OTES: lK.£SS On£R'WlSE stctFIED

1• PARTIAL REF"EJ<D'U OCS IGNATOOS ARE St-JJ\r'N. PREFI X WI TH


ltHT t-lJ13ER rn ~y OCSIGNATICN rn BOTH Fffi
CO'fl.£TE OCSIGNATICN.

2. ALL RESISTffi VALl£S ~ IN Ct-i1S. AlL CAPACITCR VALl£S


N*: IN MlffiCf'"ARADS.
3. NOT PART CF CIRCUIT BOARD.

AlAI 189667 Rev. B


Figure 7-1. Control Panel (Sht.l of 2).-

Change 3 7-3lS?~_Blank)
816R-2C DIAGRAMS

TO AI£PSITBl-4
+2fN
::rJ3-33
+2'iJI/ rh~1
01 47.51<

RSB
100
3
U3-A
LFI3202
2

r-------,
t I'U..TH£TER I
I I
I I
R45 ~ I
C32 IK TBI-AI I
I I
~.I I
I
Jt-21 R48 I
IK
I
C33 I
~I
GRIO ~ J3-21
TQ~I6 1 -.1I
SIT NJTE 3
R52

scRE:E:.N va...TAGE:
TO A5E5 ::J
J3-25
1.2M

R)J
>
10
+

JI-22 R54
C35 10<
BIAS VQTAGE
TO AI0AITBI-7
J3-22
~.I

>
II}
+
S15
~
~
«
N II}
f'-. 7 L&-G 10
r-- 47
oc ~ I.&-A
7404
R15
-+'5V

al
oc
lEi
N
2.2K
ura
7404 1=1 4 l&-{) 13

~t~
>
10
47

al
S14 « ~ 47

~I~
10 I PA BIAS I
5 l&E 12
47

~;]
r--------,
I I .r---------.,
I I I PCMR OVTPVT I
I J I I
PIO TBI I I I N4 I
TBl-£J I I I
TO Ai2AI-38~~_+__i 5 + I 181-C1 I
f 3 I
I I
> I

t
I >
I ~ I
I
r-.--=---"---i 6 - :
1 -1 L J
SEE NOTE 3 SEE NJTE 3
>
In
~ ~ ~ -
[~I
+

r-------,
I I
I f
I f
I I
TBI-Gf- I
TO A5Al~l r=-=--.~ 7 + J
J
I
I
I
TO A5AI~2~--=-_+__i I
I J
J
SEE NnE 3

Figure 7-1. Control Panel (Sht. 2·o(2).

Change 3 7=5/(7-6 Blank)


816R-2C
DIAGRAMS
-f-15VIJC +51~{}C
U9 WO
Plo PI MC7815CT MC7{j-05CT
4-0 ~I R33
~_
-,
r---.JVV'---------.....
65
I
~
2 R34 I
.............-----............................---..r~.'----t
G8, /IV
.....
~..........................-..................--~V%_--- F._+_'___'___,
At/TO MAN
2w
CRI
+ _ +
1 1I00~~voc.3
C28

o~~l l~
IN4-(X)7

O~/~
-f.5VOC
3
R3 r-----t!to-'----'--.... K/) ~KI
r'-----.I / /6 + R /2
CZ4 ~~ -f5VOC 1?8 +SVOC -i·5VOC +5VDC .

:JO04~+ Ii< 2 /5
UI 3 14
-7400
eRz. R0 4 I~
-. J INW07 4.71< VO, X/.)6 C5 8 CLUTCH 5 /2 L2
4-2. ~-------" .h II 4.7pH PlOPI
.---f----f---t I 8 O·/tiF U4, XU4 7 /0 t----........ _.._.........t-----+ I3
34- ~~-------------' -f/5VOC +15VDC Uf 8 9 ,$_

Lf
-----+--1

3
2 7
/; .........-....--
2
..--~~3:;.....1
D5/
/2
,.., D 11
IOOC~~ l
RI
2 .. 21.< OG1+ t/7>XU7
CIS --------I .,. .A
5
.+ /<7
50K, ~~ YelLOW
_t---~-t

DS? )'? LOWER


K2) XJ<2
+ RI4
AC (jNO

I
I Cf4
Y2'W {AF
CIS
AD536A O.I.LJF
55!!; ~:;:J~,qF REO
R13·
& . - - - - - 4.. /

2
16 "--"--""~-...I 1-5VDC
/5 330
I +5VDC 3 14
,RVIIOOPFl /4 330 - 4(. 15
2 /3 C20 5 /2 L3
RIa I; II 4.7#H
J AC Glfij 3 /2 +1511.0C RIO 7 10 ...-----........ ~ 25
20K -04

I ;4- II 8 9 Z~
390
I
,~:Fl
TPI 5 /0
R/9
I • h 9 10K
I 7 8 DS3
+5VDC REO /8
2
R/7
R/5
"~ )(!J,XK3
Rlf 330
49 O./~F
i--
1 16
+ R/~
22K 390 '------4 I-----J'VV'---f., 1

Cl7
+ C.31
/\'30
IX
R3/
IK 2 15 530
50
?2,4Fl CI(J
R2/ R24
5 +
3
uz .3
4
14-
/3
2.2pF
+ /OOpF 100
10/0
/01<
A
2 ~ l1: L4
4 b /1 4.7;li#
(/8 7 /.() ........----41.... ~ ............~ zq
R25 XU8
10K U2 8 9 30
R22
100 R28
CI3 1
/90 /OOpF;f,
2. 2M
R2'6 L...- AC (;NO ~ - 22.
7400
10K
R23
10K
R27
10K NOTES: UNLESS OTHERWISE SPECIFIED
L PART/ilL REFERENCE OE5/6lvrlTIONS liKE Stlowr).
RP9
PREFIX WITH UNIT .'VUMBER OR SUi3ItSS£Mf3LY D~S/uNITTION
OR BoTH FO/? COMPLETE D£SJ4."lnT/ON.
~. ALL RESiSTOR VALUE5 t9-RE IN OHMS" Y4w,t&S%.

OS4.
GREeN
A2A4 182902 Rev. -

Figure 7-2. Filament Regulator Schematic Diagram.

- ... _--~-_ .. ----:-:---:-.---~--=-,-,.

"7-7/(7-8 Blan~l
816R-2C DIAGRAMS
.11-16

JI-14

.JI-12

JI-10

~ ~ UI U3
~ ~ ~ ~\ 555 55S
N N

A~.TRIGGER
.---_+,---...Z 2
'-'--+1---liA"-4TRIGGER
R23 ~RSf.T
OS l....-..."LRSET
R21
.... ./GATE 10K
r-;=:t COU/VOLT ...--f CONIVOLT
~~~
THRHOlO
l
,...-..Y..
10 MCR1906-S
5= '-- N
N
~
~ OUTPUT r 3
:>f----t---.....---i f...-+-_--1 1.. ~OISCHAR ~
cr II
.1
OUTPUT! I U2
52400
'---+-------r------+-O--.lIL1--.,
,...--.t-_~41~Y---
L--.

rll

,:! LO....
co

JI-4 04... ,/
GATE
R20

4.7K
1 ~
~I
~,
()- r-~
-
~ ~

~I- l'lf~
j-
IN4004
MCR1906-6
l ~ :=-:
()
0'>
cr
&
N
N
t1
U2
7~12 1~0
U2

,3
VSWR
OVLD ~
\. - 13 zl -
r;7 >
<X>
N
(\ +

. RECYCLE -.... SI
R28
TEST -
OS GATE
Jt-6 ....t/ 4.7K
MCRJ906~6
l ~= .
'--
,...- f'
N
a::
&
N
N
~, ,.~
5- ~~
~

RI7 03

~
PA PlATE
- 2N2222A
OVLD '---- RI3 2N2222A (1 ~ 4.7K

206_43-,~
L..--..
&
co JI-18
fj J0K (\1& co- r--.t"
::> ~
f' J ~J ~; Z
. -_ _M£
__

:: ~= ~-:
~ ~
oj
,.....&
~~ ~~
z
cr

GATE R26
U
- r/7
JI-8 07.... 1/
4.7K
HCR190~6
l ~=
,--
r- •
'"
N
a::
&
N
N
r17

PA SCREEN
OVLO ~

r.7

>
6 2
'I",
7 8141

-r-----z-'
AUTO
RECY~E
ON J 1- 20
L1 10
+ S2 OFT ~ ~l-~----~
Jl-22
100uH
Jl-24

U4
U6
I JI-26
555
S55
us
I ~ TRIGGER 749ZA
.----1--~~:~TRIGGER >
<X>
~RSET N
~CoN/VOLT r---t-e--..l7'-f~:~ ~RSET
~CON/VOLT
+
~THRHOLD
~DISCHAR 3 RS
OUTPUTr=------t-'--..JV'V'v--_ _~
It<
01
2NZ222A

OA~ El
~THRHOLO
~DlSCHAR : ~
OUTPUT~
RI2

JS0
t "1-27
"-
L-.lfCKA OBI l-28

P
Q
~iCKB OC~h EZo- ~_ .... -
00 I~ u-~ . JI-Z9
,--,
Jl-30
>
'"+
n

[NOTES. UNLESS OTHER\lISE SPECIfIED

1. PARTIAL REfERENCE DESIGNATIONS ARE SHOWN. PREfIX \11TH


UNIT NUMBER OR SUBASSEMBLY DESIGNATION OR BOTH fOR A2A5 180167 Rev. -
COMPLETE DESIGNATION.

Z. ALL RESISTOR VALUES ARE IN OHMS, ALL CAPACITOR VALUES


ARE IN MI CROF ARADS •

Figure 7-3. OverloadfRecycle Schematic Diagram.

7-9/(7-10 Blank)
816R-2C DIAGRAMS

RJ7
"1-32
82S
"1-34
~ ~
"1-36
a::
> ~ ex
CR3

·t
R38 lN4007

JI-30
01 4.7K ~ ..,.
N
ex
~
N
2N3053

~T~ ~I~
n7 TN

"1-20

JI-18 SPARE GATES


R57
JI-16
479
~ ~
..J..l=.ll..) ~
~ ~
~ ~
TP5
~ ~
~ ~
~ ~
~ .Jl.=J.4
JI-8
RII ..J.1.::14 .J.t.::Y
~ ~
TP2
~ ~
JI4;

>
N
+
"1-46 R54

RI7 C4 tOO
I JI-2B)
.1

51

-12V
+12V....-.20
REFL FOLOBACK
TEST
OFFSET
",---~'-----4~-------4--.-+t2V
160K
U)
JI-50 ex
o

OISAlll£;,Y ~ ;' ENABlE


( JI-44
---------to<&
VS'JR PROTECT
L..-----4~--_...---_4- -12V

R56 VR4

+-: -= :J=-I~. .: 4-= : ,~


~
1N474e l >
N
>
N
I I

8.2K
RI6 R31
JI-14
15K
TPI CR7 NOTES'~ESS OTHER'tII$( SPECIFIED

IN4te7 1. PARTIAL REFERENCE DESIGNATIONS ARE SHOWN. PREFIX 'tilTH


R53 RJ2 UNIT NUH8ER OR SUBASSEl1BLY OESIGN,\TI ON- OR BOTH FOR
JJ-J2 COI1Pt.ETE DESIGNATION.
ZZge ex 41f1<
o C9 2. ALL RESISTOR VALUES ARE INOHt1S., AU CAPACITOR VALUES
R51 ARE IN H1CROf"ARAOS.
JJ-:lS
CIS

U3
1741
l.
R3e
-J2V 10K

JI-38

iUA6 180162 Rev. A· ---

Figure 7-4. Power Monitor/Contro)'ScbematicDiagram.

7~1'1/(7-12 Blank)
816R-2C
DIAGRAMS
S3 PA tIL

1N4007

R4
K£2 ,JI-l Rl 01
FIlAI1JiT 8.g])( 51<

6----------.>-- ~ A2Hl(+)
A6C81-4 JI-8 R6 RI0
PHASE A-B 6.19< 62i'l0

ASC61-6 JI-6 R2 R3
~B-C 6.19< 6200

A6CB1-5 ,JI-3 R7 R9
PHASE C-A 6.13< 6200

to
::s::

r------- -+ -+- ~ A2Ml(-)

tn-c
7-432

,Jl-2
..11-5
,)1-3
...II-IS

UI-A
556N
~2
U4-E 47
6 TRIGGER 7404
4 RSET 11 19 ~I
3 CO'VVU..T 47
~ ll-fUHU)
lJ4.-F
7404 7~0
DI~5 13 12 47

~
47
33 IN40irl

!'DTES: tN..£SS On£R'JtSE SPECIFIED

I. PARTIAL RE:F'ER£J'a: OESIGNATOOS 1>PE SHnJN. PREFIX WITH


ltIIT N..tOC.R OR St8ASSO"a.y OCSIGNATI~ <R BOTH FOR
CO!'PLETE OCSI~TI~.

2. AlL RESI~ VAL\.,£S ARE IN CH1S. AlL CAPACIT~ VALlES


ARE IN Hl~ARADS.

A2A7 189621 Rev. C


Figure 7-5. Card Cage Components.

Change 4 7-13/(7-14 Blank)


816R-2C DIAGRAMS

J5-2 Jl-39
J5-4 J1-49
J5-6 Jl-17
J2-4 J5-8 JI-21
J2-6 J5-10 JI-33
J2-8 J5-14 JI-31
J2-12 J5-16 JI-23
J2-14 J5-18 JI-35
J2-16 ~-20 JI-47 Jl-1
J2-17 J5-22 J13-13 JI-2
J2-.I8 J5-24 JI-43 JI-3
J5-26 Jl-41 Jl-4
J5-28 JI-6
J5-30 JI-8
J2-20 J5-32 Jl-1~
J2-22 J5-34 JI-12
J2-23 J5-36 Jl-14
J2-24
. J2-26 J5-38 JI-18
J5-40 JI-22
J2-27 J5-42 J4-14 Jl-24
J5-44 J4-16 JI-26
J2-28 J5-46 J4-1B JI-30
J2-29 J5-48 J4-20 JI-34
J5-49 J4-22 JI-36
J5-50 J4-4 JI-38
J4-6 Jl-42
J4-12 JI-44

J8-44 J7-44
J8-40 J7-40
Ja-32 J7-32
J8-28 J7-28
Ja-18 J7-18
Ja-14 J7-14
J8-8 J7-8
J8-2 J7-2

NOTES. UNLESS OTHERWISE SPECIFIED


1. PARTIAL REFERENCE DESIGNATIONS ARE SHOWN. PREFIX WITH
UNIT NUMBER OR SUBASSEMBLY DESIGNATION OR BOTH FOR
COMPLETE DESIGNATION.
2. ALL RESISTOR VALUES ARE IN OHMS. ALL CAPACITOR VALUES
ARE IN MICROFARADS.

A2A8 180196 Rev. A


Figure 7-6. Backplane Schematic Diagram (Sheet 1 of 2).

Change 4 7-15/(7-16 Blank)


816R-2C DIAGRAMS

J3-1 C ( J13-4 OJ- J9-23 ) 0 Jt0- 9


J3-2
J3-6 CY
J9-34 CRt DQ
Jt-16 D
110V C-A
470 IN4003
+tg

°I~
110V C.J3 CR2
D J12-7
lN4003

< Jl-28 On T~~~=~7 g


110V C-C
R8
Jl-46 J~-12 )
DG 100K
~
N R9
N ~ J10-19 DT
110V C-D 270
~
01 to
OJ IV)

( Jl-32 ON J~~ 5 . MOUNTING HOLES


J3-38 0 T ==38 5
( Jl1-6

Nl~
J6-32
J6-28
J6-18
UI~ J6-14
J6-8
J6-2
T85-8
~ J11-9 0.0 Jl-20 )
J9-35 T

A2AS 180196 Rev. A


Figure 7-6. Backplane Schematic Diagram (Sheet 2 of 2).

Change 4 7-17/(7-18 Blank)


816R-2C DIAGRAMS
A3
----~----.----------- ........
I I
I I
I OCI

-·l
o.RECroNAt..
COUPlER

J2 IN <>UTI
RF INPUT ) JI-1 RESET
fROU
EXaTER ~~2t.£TER RF OUTPUT -
TO ANAL
WI JI4
___ ~~~_+2'" AMPUflER
15 OHU AI
~90"~

P/O
10000--':O:; I
1-A2~__tJ
PIa ~Sf 195079-'
TBI
TBI
'I' SCHEU 195080

I
RESET 20
I r:IPA STAtus
A$S'( 189625-1
SCHEM 189626
. I 6
5

7
REVERSE INPUT
"GROUND

fORWARD INPUT I
INPUT

REMOTE 19
I II 3 GROUND
I
RESET
I I I
I POWER
EI
20 POWER lED

~)t!::.2 WET£R
lP2
I I E2
18 VSWR lED I
+--t---~J_J'--4+24
+24V IN 18
t-- - __

I I L -. _ IVSWRJ
--.J
12 METER

.. METER-
+
I
I , I
GROUND
(fROU RECTlFlER) 3
J I 8
GROUND

CURRENT - I
F2
XF2
23CN
5O/6OHZ
.. Bt

I 12A I 4 POWER INPUT I


FI
2
XFI
I I
L_ . . . . . _~_. . . 12A
.-J
·9 CURRENT

---
.+
J
RI
SHUNT
.016 OHM 2-
+5(N IN
(FRON CHOKE) R2
'OOW
50

NOTES: UNLESS OTHERWISE· SPECIFIED

I. PARTIAL REFERENCE DESIGNATORS ARE SHOWN.


PREFlX WITH UNIT NUMBER OR SUBASSEMBLY
DESIGNATION OR BOTH fOR. COMPlETE DESIGNATION.
A3 • .. • - 'P'
19512 5 Rev.-
__ _: _ •• _ . ·0.

2. ALL RESISTOR VALUES ARE IN OHMS.


~

AlL CAPACITOR VAlUES ARE .IN MICROFARADS. Figure 7-7. Intermediate Power Amplifier (lPA) 816R Schematic Diagram.

Change 5 7-19/(7-20 Blan~)


816R-2C DIAGRAMS

PI-6
REFLECTED IN

PI-18
-vswR w LED

PI-J7
VSWR STATU>· CUT

R24
RS PI-15
lK
REFlEClID SAl"FLE CUT
lK

Fffi'tlAffi IN )PI-7
RI7 PI-IS
lK FCRJAR!) SN'PLE CUT
lK

ffil

PO\oIER 1t-PVr Pl-4 R33


+S6V IN lK

R3 Pl-2e "'f'()W'ffi- LED


7.51<
~
~
~
PI-J9
VQTw:;£ SN'PlE CUT
..., ~
0::
~ ~
~
:.
u
,..,
N
VQTAGE CAL
~
0::

C81GR mT USED)
PI-2 35" :: 35 HILLIVQIS RZl
fRa1 9-UfT - Rf2
lK PI-14
aP.R£NT S»f'LE
lK

[10 Pl-J0(
RZl
CV 2K PI-=-J3(
£20

FRa1 SUfl-y + )>-=oP.,:..1-..,::9 _

(816R e:tRRE:NT + ) i- I
=:;
N
I
=:;
l"')
I
=:; ~
~
PI-J2
t£TER +
~
~.- t£
(BIGR ...ut'[R JI-t TO Jl-2) Pl-ll
I'£TER -
(Fa ..uf'[R JI-2 TO JI-J)

SI-B
~

FRa1 St.FPly.
(8'ER CU<RENT -)
)rP...:.l-a~___________
1l· n
~~ ~ rn

C81GR ..U'f'ER J2-1 10 -.)2-2> -oHI A3Al 195080 Rev. E


CFt ...uf'ER J2-2 TO J2-3> -0112
Figure 7-8. Metering Card Schematic Diagram.

Change 4 7-21/(7-22 Blank)


816R-2C DIAGRAMS

POWER
DSI-A
A3P t -v
El 6 'It
------O------t---t-.-...+-~........,

MV54173
DSI-B
4~ 3

VSWR
OS2-A
E2 6 ~~1
A3P l-C ---------( J-------t-t--~N_+_-_+_t
MV57173
DS2-B
4~ 3

IPA
FAULT
DS3-A
A3PI-P
E3 6 'll
MV57173
DS3-B
E4 4~ 3
A3ARITBl-2

NOTES: UNLESS OTHERWISE SPECIFIED


t. PARTIAL REFERENCE DESIGNATORS ARE SHOWN.
COMPLETE DESIGNATION.
PREFIX WITH .
UNIT NUMBER OR SUBASSEMBLY DES IGNAT.ION OR BOTH FOR
TO A3 CHASSIS -----l
........
E5

"-
A3A2 189626 ·Rev. -

Figure 7-9. IPA Status Schematic Dirtgram.


816R-2C
DIAGRAMS

t- t- t-
:J :J
2 :J
Cl. t- ..!-o o.. Cl.
:J ~ a
t-
a.. ZZt- ~ ~
ti~ wo:;:::)
:J Z
0 ~
V)~
O:::wo.
~ ~ :J
u.. u.. Wt- ~Gi5 ll) N
0
0:::
0::: 0:::: 0::: V> u~o + + 0

AI

3 4 )5
~l
z

VlEW OF J I FROM ~
OUTSIDE OF AMPLIFIER

I
I
Al
RF
ASSY
-----
189213-
-------------- -, r
A2
---------------------- VR201 CONTROL SWITCHED E2
SCHEM 189214
I IES
24V
R202 CR202 LM317HV
wl:t----....---.-----1I~-------_.-T_15V
ASSY 189210-1
SCHEM 1892 I I
OUTPUT

1+ 10 IN4004

I .~ I ~

~l~
{S} IS)
IS)
N
5 !
I THERMOSTAT I I
(CLOSE @ +80C)

I
I- {S} ~
I
$1
EIOI ~
~
RI02
0203

I
22
RI03 I I E4
S2V
S
IRFP9140
0

I+
I CIO?

+50 VOLTS

I
-
(\J
0::
~
-v
N Q201
2N3906
G

I
I TLI03
50 OHM RG-303 U201-A
~ to ~
HIGH IF SHUT OfT

J. CI08

.001
BALUN I METERING
OUTPUT R216
CP2S3 a:::
+6V
ro
to
re
0::::
0 LOW = NORMAL

22 iF SCR CR203
::N ...----..rR22
v£.v5v-_---t....._
I· RI05

22
R215 a:: 0
o
FIRED
475 1N4004
....

I RI07 RIIO
EI031
332K MET
SAL
If)

I B!AS
N)J
RI09
5K
Q'j
o
0
g
3900 IK

0::: to
cw
APPROX 0 V
,.:.1 II

:I L-L_-_-_-_-_-_-_-_- - -_-_-_-_- - _-_-_-_-_-_-_-_- - - _-_-_-_-_-_-_-_-_-_-_- -_-_-_- -_-_-_-_...:..1l:I~O_4~_-_- - _-_- - _-_-_- - -_-_-_-_-_-_- -_-_-_-_~c:i50r20~HmME]iREJ[;-.13.D16IT~=============t===::...--J
301
R218
IF SCR FIRED
OR OVERTEMP

332K
>
lO I-
\1 -I-

I
I ~i ~ ~
!I R222
___
I I+
R219
ISV.-.......-J\f\I\r-~~-~~~
~-.------'·VV'V-------------

I.IK I
II 10K

I
I I
:1
I I CURRENT-
OVERLOAD I
!I TRIP ADJ

L _ I I I
.J L - - - - - - _ ........ _-------- --- .... 1
NOTES: UNlESS OTHERWISE SPEClF1ED

f. PARTIAL REFERENCE DESIGNATORS ME SHOWN.


PREfIX WITH UNIT NUMBER OR SUBASSEMBLY
DESIGNATION OR 80TH FOR COMPLETE DESIGNATION.
A3A3AI~A2 , 189397 Rev. A
2. AlL RESISTOR VALUES ARE ·IN OHM$.
All CAPACITOR VAlUES ARE IN MICROFARADS.
Figure 7-10. Amplifier Module Schematic Diagarm.

Change 3 7-25/(7-26 Blank)


816R-2C DIAGRAMS
R202
1~--:"-_"""------------'--------------...+15V
10

+52V IN E4 n - - - - - -
~------
....
-R20I\/\\)1\9/-_+_----_4--------.._---_....--.._---_...-~rt_~~~--__,~------_vE2 SWITCHED OUTPUT
.05

U201-A
OP283 -+ ...-3 __
CURRENT R216
METER I NG E60---e--------'\/\/\r---_e_---<.,.
OUTPUT 200 2
CR203
C202

.0~ R215 475 IN4004


332K
C208

RESET &
.0~
STATUS
R223 r--..
OVER TEMP E 1 O--------J\/\/\r----J N -
301 cr

332K
E3 l J-------,
U201-B
5 OP283 MOUNTING
+ 7 R222
R219 6
HOLES
+ t5Y..---...-..J\I'\/\r--..----t---i t.IK
10K HI

HZ
(J) (\J
M3

reI~
u .
M4

>
to
-.;

NOTES: UNLESS OTHERWISE SPECIFIED

1. PARTIAL REFERENCE DESIGNATORS ARE SHOWN. PREFIX WITH


UN I T NUMBER OR SU3ASSEMBL Y DES IGNATI ON OR BOTH FOR
COMPLETE DESIGNATION.

2. ALL RESISTOR VALUES ARE IN OHMS, ALL CAPACITOR VALUES


ARE IN MICROFARADS.

3. E1 THRU E7 ARE FOR REFERENCE ONLY • -


A3A3Al~A2Ai
-

< 189211 Rev. C


Figure 7-11. Control Circuit Card Assembly.

Change 3 7-27/(7-28 Blank)__


816R-2C DIAGRAMS

RI02

22
ro SI

81-
oEIOI TO EI

RI03 °1~
22
CI02 CI07
EI02 TO E2
lO
0
+50 VOLTS

0
-
lJ.-
0
0..
If)
0
n 0
-
0
to
T"'OI
<D
0
-
.q-
lOO
~-
0 LI02
°1'
,n
0 n:: n n::: to .-l .-l CI05
I to 0:::
00 0
- TLI03
0 50 OHM J2
RG-303 (BNC)
BALUN
BLF27B
RI04 MRFI5JG .001

22
RIOS

22

RI07 RIIO
-'\f\tv oEI03 TO E3 + 15V
IK
0
REF 0
(J)
VALUE to
CW

TLI04
50 OHM JI-AI
RG-316

NOTES: UNLESS OTHERWISE SPECIFIED

I. PARTIAL REFERENCE DESIGNATORS ARE SHOWN.


PREFIX WITH UNIT NUMBER OR SUBASSEMBLY
DESIGNATION OR BOTH FOR COMPLETE DESIGNATION.

2. ALL RESISTOR VALUES ARE IN OHMS.


ALL CAPACITOR VALUES ARE IN MICROFARADS.

3. TL 104, Q J AND S J ARE" FOR REFERENCE ONLY.

A3AjAi,~A2A2 ,1'89214 Rev. B


Figure 7-12., RF Circuit Card Assembly Schematic Diagram.

) Change 3 7-29/(7"-30 Blank}


816R-2C DIAGRAMS

I , I
. lO
m __ ~
~Ull It I (I _Ill l~l'i'El"l N
Ifq If:q I~ 1m I~ I, -
t-- 't--

Rl
~J"
./JI-l
)Jf-2 T
bS I ~ 13
9 I
33
J2-2,
J2-3<"
/.

"'
./JI-3
)JI-4
CRl
I~
,..... J Lbr 9 f b:LJJ
I 8
"7

:6 ~~ ~O
1
"- J2-4, ,
q~- IS
-fW
.1 T .1
r

/Jl-5 1l
}Jt-6
)JI-7 TI
TlJ../'1
9 I
~13 J2-5,
"-
I 9 .JHi{
CR2
l~ r L:±7r
8 I
H
L 8 ' ,
JC-7,
.J2-9(
/

./.)1-9 rJ

:6 ~~ ~O
..... 1 J2-9{

4 .1 I
IS

1
f~
.1
../

.~ Jl

~
/Jl-9
) ..11....1"
..... T 9 I
J2-1e, ,

/.JI-ll
1~
au
JIII"',
I L£:;f 8 I
H
f 8

:6 ~~ IO
..... J J2-11 ,

W .1 i
IS

I
~~

.1
/

00-------,
/,)1-12
")JI-13 .
It
ffiD
I8IGlOU
I 2
1 • I h ~J2"
../

"'
TlJ~
T 1 S Lij
r7I

.1 I
_15
_ _ ._ _ _ ..;;.....r

1~
tR4
IL:±7r 8 f i'.
i.._
... II
13
J2-13
..J2-14
.J2-15
/"'1-14
~
r

:6 ~~
~j
,i..
..........
9
S
42-16
J2-17
·4[-1 -i
.8
J2-18

0 16

1
I
f3~
.1
.J2-19, ,

~
rJ
1N4007
"'1-16

Jf-l.S
JI-17
N>TES: \JUSS cm£RVlSE ~IfIED JI-18
JI-19
I, PARTIAL REF'EJVI:£ OCSIGmTtRSN£fHNN. 'PREFIX VITH'
lN1T N.JU:R CR s:LeASSOQ.y OCSIGNATI~'M B01H F'M 194874 Rev.-
t:XKU1E ££SI~TICI'f.
2. ~ F£SlSltRVAl..lO N£. IN (Ift). AlLCAPACITCR VAllO Figure 7-13. Remote Control Schematic Diagram.
N£ IN ttI(R(f"ARAL)S.

Change-S :'7-31/(7-32 Blank)


PRODUCT SERVICE BULLETIN
EIMAC 4CX15000A, 4CX20000E, 4CX25000C AND 4CW30000A TUBES
JUNE 22, 2007

EIMAC has learned more about the best way to operate these tubes with regard to filament
management. These operating instructions can be found in EIMAC Application Bulletin AB-18.
Specifically, you should lower the filament voltage after the first 200 hours of operation. After
operating a new tube for 200 hours, the filament voltage should be reduced to the power
emission knee required for your output power.

WARNING
HIGH VOLTAGE IS USED IN HIGH POWER EQUIPMENT. HIGH VOLTAGE CAN
CAUSE SEVERE INJURY OR DEATH. INSURE THAT ALL CIRCUIT BREAKERS
ARE OFF AND PRIMARY POWER IS DISABLED WHEN MAKNG ADJUSTMENTS
INSIDE THE TRANSMITTER.
DISCHARD ALL POWER SUPPLIES BEFORE MAKING ANY ADJUSTMENTS.

INSTRUCTIONS

First, stabilize the new tube emission by operating it a rated filament voltage for a minimum of
200 hours. With the transmitter in manual power control at 100% power, carefully lower the
filament voltage in 0.2 volts steps, pausing for at least 30 seconds after each decrement, until you
see a significant (greater than 2%) change in power output or plate current. This is the filament
emission knee. Now raise the filament voltage 0.2 volts above the knee voltage. This is the
correct filament operating voltage for your power output. Operation at this reduced filament
voltage insures maximum possible tube life.

Recheck the filament knee voltage again after 24 hours to determine if the emission is stable. If
not repeatable, repeat the derating procedure again.

Please contact Continental Electronics Field Service with any questions or comments.
214-388-5800

Вам также может понравиться