Autodesk Robot Structural Analysis Professional 2020

Fixed column base design


Eurocode 3: EN 1993-1-8:2005/AC:2009 + CEB Design Guide: Ratio
0.79
Design of fastenings in concrete

GENERAL
Connection no.: 4
Connection name: AXIS 27/K DETAIL CB02
Structure node: 23878
Structure bars: 7748

GEOMETRY

COLUMN
Section H 300x300x84.5
:
Bar no.: 7748
7
L . [ Colum
c
3 mn
= 5 ] length
[
a0 D Inclina
. e tion
= 0 g angle
]
Height
2 [ of
h
mcolum
c 9
4 mn
=
] sectio
n
7
L . [ Colum
c
3 mn
= 5 ] length
Width
b 3 [ of
f
0 mcolum
c
2 mn
= ] sectio
n
Thickn
ess of
t [ the
w 1 mweb of
c 2 mcolum
= ]n
sectio
n
Thickn
ess of
the
[
tf 1 flange
m
c
2 mof
= colum
]
n
sectio
n
Radiu
[ s of
r1
mcolum
c
8 mn
=
] sectio
n fillet
Cross-
1
0 [ sectio
A7 nal
c
c
. marea
= 7 2 of a
]
0 colum
n
1 Mome
6 nt of
I 9 [ inertia
y 0 c of the
c 0 mcolum
= . 4] n
0 sectio
0 n
Material S235
:
fyc = 235.00 [MPa] Resistance
fuc = 360.00 [MPa] Yield strength of a material

COLUMN BASE
lpd = 700 [mm] Length
bpd = 700 [mm] Width
tpd = 25 [mm] Thickness
Material: S235
fypd = 235.00 [MPa] Resistance
fupd = 360.00 [MPa] Yield strength of a material

ANCHORAGE
The shear plane passes through the THREADED portion of the bolt.
Class = 4.6 Anchor class
fyb = 240.00 [MPa] Yield strength of the anchor material
fub = 400.00 [MPa] Tensile strength of the anchor material
d= 20 [mm] Bolt diameter
As = 2.45 [cm2] Effective section area of a bolt
Av = 3.14 [cm2] Area of bolt section
nH = 4 Number of bolt columns
nV = 4 Number of bolt rows
Horizontal spacing eHi = 180;180 [mm]
Vertical spacing eVi = 180;180 [mm]
Anchor dimensions
L1 = 150 [mm]
L2 = 530 [mm]
L3 = 100 [mm]
L4 = 0 [mm]
Washer
lwd = 50 [mm] Length
bwd = 50 [mm] Width
twd = 10 [mm] Thickness

STIFFENER
ls = 700 [mm] Length
ws = 700 [mm] Width
hs = 400 [mm] Height
ts = 20 [mm] Thickness
d1 = 50 [mm] Cut
d2 = 20 [mm] Cut

MATERIAL FACTORS
gM0 = 1.00 Partial safety factor
gM2 = 1.25 Partial safety factor
gC = 1.50 Partial safety factor

SPREAD FOOTING
L= 800 [mm] Spread footing length
B= 800 [mm] Spread footing width
H= 1000 [mm] Spread footing height
Concrete
Class C30MPa
fck = 30.00 [MPa] Characteristic resistance for compression
Grout layer
tg = 50 [mm] Thickness of leveling layer (grout)
fck,g = 12.00 [MPa] Characteristic resistance for compression
0.30 Coeff. of friction between the base plate and
Cf,d =
concrete
WELDS
ap = 12 [mm] Footing plate of the column base
as = 12 [mm] Stiffeners

LOADS
Case: 34: ULS8(1.2DL+1.0LL+1.6WIND X- +0.5RL) (1+2+30)*1.20+3*0.50+29*1.00+63*1.60
Nj,Ed = -23.81 [kN] Axial force
Vj,Ed,y = 0.54 [kN] Shear force
Vj,Ed,z = -12.18 [kN] Shear force
Mj,Ed,y = -20.74 [kN*m] Bending moment
Mj,Ed,z = 0.73 [kN*m] Bending moment

RESULTS

COMPRESSION ZONE
COMPRESSION OF CONCRETE
fcd = 20.00 [MPa] Design compressive resistance EN 1992-1:[3.1.6.(1)]
fj = 15.24 [MPa] Design bearing resistance under the base [6.2.5.(7)]
plate
c = tp Ö(fyp/(3*fj*gM0))
c= 57 [mm] Additional width of the bearing pressure zone [6.2.5.(4)]
beff = 125 [mm] Effective width of the bearing pressure zone under the flange [6.2.5.(3)]
leff = 415 [mm] Effective length of the bearing pressure zone under the [6.2.5.(3)]
flange
Ac0 = 520.72 [cm2] Area of the joint between the base plate and the foundation EN 1992-1:[6.7.(3)]
Ac1 = 3008.75 [cm2] Maximum design area of load distribution EN 1992-1:[6.7.(3)]
Frdu = Ac0*fcd*Ö(Ac1/Ac0) ≤ 3*Ac0*fcd
Frdu = 2503.37 [kN] Bearing resistance of concrete EN 1992-1:[6.7.(3)]
bj = 0.67 Reduction factor for compression [6.2.5.(7)]
fjd = bj*Frdu/(beff*leff)
fjd = 32.05 [MPa] Design bearing resistance [6.2.5.(7)]
Ac,n = 1895.49 [cm2] Bearing area for compression [6.2.8.2.(1)]
Ac,y = 715.86 [cm2] Bearing area for bending My [6.2.8.3.(1)]
Ac,z = 738.02 [cm2] Bearing area for bending Mz [6.2.8.3.(1)]
Fc,Rd,i = AC,i*fjd
Bearing resistance of concrete for
Fc,Rd,n = 6075.06 [kN] [6.2.8.2.(1)]
compression
Fc,Rd,y = 2294.33 [kN] Bearing resistance of concrete for bending My [6.2.8.3.(1)]
Fc,Rd,z = 2365.37 [kN] Bearing resistance of concrete for bending Mz [6.2.8.3.(1)]
COLUMN FLANGE AND WEB IN COMPRESSION
CL = 3.00 Section class EN 1993-1-1:[5.5.2]
Wel,y = 1996.49 [cm3] Elastic section modulus EN1993-1-1:[6.2.5.(2)]
Mc,Rd,y = 469.18 [kN*m] Design resistance of the section for bending EN1993-1-1:[6.2.5]
hf,y = 356 [mm] Distance between the centroids of flanges [6.2.6.7.(1)]
Fc,fc,Rd,y = Mc,Rd,y / hf,y
Fc,fc,Rd,y = 1317.69 [kN] Resistance of the compressed flange and web [6.2.6.7.(1)]
Wel,z = 1709.25 [cm3] Elastic section modulus EN1993-1-1:[6.2.5.(2)]
Mc,Rd,z = 401.67 [kN*m] Design resistance of the section for bending EN1993-1-1:[6.2.5]
hf,z = 199 [mm] Distance between the centroids of flanges [6.2.6.7.(1)]
Fc,fc,Rd,z = Mc,Rd,z / hf,z
Fc,fc,Rd,z = 2023.11 [kN] Resistance of the compressed flange and web [6.2.6.7.(1)]
RESISTANCES OF SPREAD FOOTING IN THE COMPRESSION ZONE
Nj,Rd = Fc,Rd,n
Resistance of a spread footing for axial
Nj,Rd = 6075.06 [kN] [6.2.8.2.(1)]
compression
FC,Rd,y = min(Fc,Rd,y,Fc,fc,Rd,y)
Resistance of spread footing in the compression
FC,Rd,y = 1317.69 [kN] [6.2.8.3]
zone
FC,Rd,z = min(Fc,Rd,z,Fc,fc,Rd,z)
Resistance of spread footing in the compression
FC,Rd,z = 2023.11 [kN] [6.2.8.3]
zone

TENSION ZONE
STEEL FAILURE
Ab = 2.45 [cm2] Effective anchor area [Table 3.4]
fub = 400.00 [MPa] Tensile strength of the anchor material [Table 3.4]
Beta = 0.85 Reduction factor of anchor resistance [3.6.1.(3)]
Ft,Rd,s1 = beta*0.9*fub*Ab/gM2
Ft,Rd,s1 = 59.98 [kN] Anchor resistance to steel failure [Table 3.4]
gMs = 1.20 Partial safety factor CEB [3.2.3.2]
fyb = 240.00 [MPa] Yield strength of the anchor material CEB [9.2.2]
Ft,Rd,s2 = fyb*Ab/gMs
Ft,Rd,s2 = 49.00 [kN] Anchor resistance to steel failure CEB [9.2.2]
Ft,Rd,s = min(Ft,Rd,s1,Ft,Rd,s2)
Ft,Rd,s = 49.00 [kN] Anchor resistance to steel failure
PULL-OUT FAILURE
30.00 Characteristic compressive strength of
fck = [MPa] EN 1992-1:[3.1.2]
concrete
fctd = 0.7*0.3*fck2/3/gC
fctd = 1.35 [MPa] Design tensile resistance EN 1992-1:[8.4.2.(2)]
Coeff. related to the quality of the bond conditions and concreting
h1 = 1.00 EN 1992-1:[8.4.2.(2)]
conditions
h2 = 1.00 Coeff. related to the bar diameter EN 1992-1:[8.4.2.(2)]
fbd = 2.25*h1*h2*fctd
fbd = 3.04 [MPa] Design value of the ultimate bond stress EN 1992-1:[8.4.2.(2)]
hef = 530 [mm] Effective anchorage depth EN 1992-1:[8.4.2.(2)]
Ft,Rd,p = p*d*hef*fbd
Ft,Rd,p = 101.28 [kN] Design uplift capacity EN 1992-1:[8.4.2.(2)]
CONCRETE CONE FAILURE
hef = 87 [mm] Effective anchorage depth CEB [9.2.4]
NRk,c = 7.5[N /mm0.5]*fck0.5*hef1.5
0 0.5

NRk,c0 = 33.14 [kN] Characteristic resistance of an anchor CEB [9.2.4]


scr,N = 260 [mm] Critical width of the concrete cone CEB [9.2.4]
ccr,N = 130 [mm] Critical edge distance CEB [9.2.4]
Ac,N0 = 676.00 [cm2] Maximum area of concrete cone CEB [9.2.4]
Ac,N = 520.00 [cm2] Actual area of concrete cone CEB [9.2.4]
yA,N = Ac,N/Ac,N0
Factor related to anchor spacing and edge
yA,N = 0.77 CEB [9.2.4]
distance
c= 130 [mm] Minimum edge distance from an anchor CEB [9.2.4]
ys,N = 0.7 + 0.3*c/ccr.N ≤ 1.0
1.0 Factor taking account the influence of edges of the concrete member on the distribution of CEB
ys,N = 0 stresses in the concrete [9.2.4]
yec,N 1.0 CEB
= 0 Factor related to distribution of tensile forces acting on anchors [9.2.4]
yre,N = 0.5 + hef[mm]/200 ≤ 1.0
yre,N = 1.00 Shell spalling factor CEB [9.2.4]
Factor taking into account whether the anchorage is in cracked or non-cracked
yucr,N = 1.00 CEB [9.2.4]
concrete
gMc = 2.16 Partial safety factor CEB [3.2.3.1]
Ft,Rd,c = NRk,c0*yA,N*ys,N*yec,N*yre,N*yucr,N/gMc
Design anchor resistance to concrete cone
Ft,Rd,c = 11.80 [kN] EN 1992-1:[8.4.2.(2)]
failure
SPLITTING FAILURE
hef = 530 [mm] Effective anchorage depth CEB [9.2.5]
NRk,c0 = 7.5[N0.5/mm0.5]*fck0.5*hef1.5
NRk,c0 = 501.23 [kN] Design uplift capacity CEB [9.2.5]
scr,N = 1060 [mm] Critical width of the concrete cone CEB [9.2.5]
ccr,N = 530 [mm] Critical edge distance CEB [9.2.5]
Ac,N0 = 11236.00 [cm2] Maximum area of concrete cone CEB [9.2.5]
Ac,N = 1320.00 [cm2] Actual area of concrete cone CEB [9.2.5]
yA,N = Ac,N/Ac,N0
Factor related to anchor spacing and edge
yA,N = 0.12 CEB [9.2.5]
distance
c= 130 [mm] Minimum edge distance from an anchor CEB [9.2.5]
ys,N = 0.7 + 0.3*c/ccr.N ≤ 1.0
0.7 Factor taking account the influence of edges of the concrete member on the distribution of CEB
ys,N = 7 stresses in the concrete [9.2.5]
yec,N 1.0 CEB
= 0 Factor related to distribution of tensile forces acting on anchors [9.2.5]
yre,N = 0.5 + hef[mm]/200 ≤ 1.0
yre,N = 1.00 Shell spalling factor CEB [9.2.5]
Factor taking into account whether the anchorage is in cracked or non-cracked
yucr,N = 1.00 CEB [9.2.5]
concrete
yh,N = (h/(2*hef))2/3 ≤ 1.2
yh,N = 0.96 Coeff. related to the foundation height CEB [9.2.5]
gM,sp = 2.16 Partial safety factor CEB [3.2.3.1]
Ft,Rd,sp = NRk,c0*yA,N*ys,N*yec,N*yre,N*yucr,N*yh,N/gM,sp
20.29 Design anchor resistance to splitting of
Ft,Rd,sp = [kN] CEB [9.2.5]
concrete
TENSILE RESISTANCE OF AN ANCHOR
Ft,Rd = min(Ft,Rd,s , Ft,Rd,p , Ft,Rd,c , Ft,Rd,sp)
Ft,Rd = 11.80 [kN] Tensile resistance of an anchor
BENDING OF THE BASE PLATE
Bending moment Mj,Ed,y
leff,1 = 417 [mm] Effective length for a single bolt for mode 1 [6.2.6.5]
leff,2 = 531 [mm] Effective length for a single bolt for mode 2 [6.2.6.5]
m= 66 [mm] Distance of a bolt from the stiffening edge [6.2.6.5]
Mpl,1,Rd = 15.32 [kN*m] Plastic resistance of a plate for mode 1 [6.2.4]
Mpl,2,Rd = 19.51 [kN*m] Plastic resistance of a plate for mode 2 [6.2.4]
FT,1,Rd = 922.84 [kN] Resistance of a plate for mode 1 [6.2.4]
FT,2,Rd = 231.31 [kN] Resistance of a plate for mode 2 [6.2.4]
FT,3,Rd = 47.21 [kN] Resistance of a plate for mode 3 [6.2.4]
Ft,pl,Rd,y = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)
Ft,pl,Rd,y = 47.21 [kN] Tension resistance of a plate [6.2.4]
Bending moment Mj,Ed,z
leff,1 = 353 [mm] Effective length for a single bolt for mode 1 [6.2.6.5]
leff,2 = 353 [mm] Effective length for a single bolt for mode 2 [6.2.6.5]
m= 70 [mm] Distance of a bolt from the stiffening edge [6.2.6.5]
Mpl,1,Rd = 12.96 [kN*m] Plastic resistance of a plate for mode 1 [6.2.4]
Mpl,2,Rd = 12.96 [kN*m] Plastic resistance of a plate for mode 2 [6.2.4]
FT,1,Rd = 736.10 [kN] Resistance of a plate for mode 1 [6.2.4]
FT,2,Rd = 197.42 [kN] Resistance of a plate for mode 2 [6.2.4]
FT,3,Rd = 47.21 [kN] Resistance of a plate for mode 3 [6.2.4]
Ft,pl,Rd,z = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)
Ft,pl,Rd,z = 47.21 [kN] Tension resistance of a plate [6.2.4]
TENSILE RESISTANCE OF A COLUMN WEB
Bending moment Mj,Ed,z
twc = 12 [mm] Effective thickness of the column web [6.2.6.3.(8)]
beff,t,wc = 353 [mm] Effective width of the web for tension [6.2.6.3.(2)]
Avc = 40.98 [cm2] Shear area EN1993-1-1:[6.2.6.(3)]
w= 0.65 Reduction factor for interaction with shear [6.2.6.3.(4)]
Ft,wc,Rd,z = w beff,t,wc twc fyc / gM0
Ft,wc,Rd,z = 644.00 [kN] Column web resistance [6.2.6.3.(1)]
RESISTANCES OF SPREAD FOOTING IN THE TENSION ZONE
FT,Rd,y = Ft,pl,Rd,y
47.21 Resistance of a column base in the tension
FT,Rd,y = [kN] [6.2.8.3]
zone
FT,Rd,z = min(Ft,pl,Rd,z,Ft,wc,Rd,z)
47.21 Resistance of a column base in the tension
FT,Rd,z = [kN] [6.2.8.3]
zone

CONNECTION CAPACITY CHECK


Nj,Ed / Nj,Rd ≤ 1,0 (6.24) 0.00 < 1.00 verified (0.00)
ey = 871 [mm] Axial force eccentricity [6.2.8.3]
zc,y = 178 [mm] Lever arm FC,Rd,y [6.2.8.1.(2)]
zt,y = 270 [mm] Lever arm FT,Rd,y [6.2.8.1.(3)]
Mj,Rd,y = 26.59 [kN*m] Connection resistance for bending [6.2.8.3]
Mj,Ed,y / Mj,Rd,y ≤ 1,0 (6.23) 0.78 < 1.00 verified (0.78)
ez = 31 [mm] Axial force eccentricity [6.2.8.3]
zc,z = 99 [mm] Lever arm FC,Rd,z [6.2.8.1.(2)]
zt,z = 270 [mm] Lever arm FT,Rd,z [6.2.8.1.(3)]
Mj,Rd,z = 94.92 [kN*m] Connection resistance for bending [6.2.8.3]
Mj,Ed,z / Mj,Rd,z ≤ 1,0 (6.23) 0.01 < 1.00 verified (0.01)
Mj,Ed,y / Mj,Rd,y + Mj,Ed,z / Mj,Rd,z ≤ 1,0 0.79 < 1.00 verified (0.79)

SHEAR
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE
Shear force Vj,Ed,y
ad,y = 1.21 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
ab,y = 1.00 Coeff. for resistance calculation F1,vb,Rd [Table 3.4]
Coeff. taking account of the bolt position - perpendicularly to the direction of
k1,y = 2.50 [Table 3.4]
shear
F1,vb,Rd,y = k1,y*ab,y*fup*d*tp / gM2
Resistance of an anchor bolt for bearing pressure onto the base
F1,vb,Rd,y = 360.00 [kN] [6.2.2.(7)]
plate
Shear force Vj,Ed,z
ad,z = 1.21 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
ab,z = 1.00 Coeff. for resistance calculation F1,vb,Rd [Table 3.4]
Coeff. taking account of the bolt position - perpendicularly to the direction of
k1,z = 2.50 [Table 3.4]
shear
F1,vb,Rd,z = k1,z*ab,z*fup*d*tp / gM2
Resistance of an anchor bolt for bearing pressure onto the base
F1,vb,Rd,z = 360.00 [kN] [6.2.2.(7)]
plate
SHEAR OF AN ANCHOR BOLT
ab = 0.37 Coeff. for resistance calculation F2,vb,Rd [6.2.2.(7)]
Asb = 2.45 [cm2] Effective section area of a bolt [6.2.2.(7)]
fub = 400.00 [MPa] Tensile strength of the anchor material [6.2.2.(7)]
gM2 = 1.25 Partial safety factor [6.2.2.(7)]
F2,vb,Rd = ab*fub*Asb/gM2
F2,vb,Rd = 28.85 [kN] Shear resistance of a bolt - without lever arm [6.2.2.(7)]
Factor related to the fastening of an anchor in the
aM = 2.00 CEB [9.3.2.2]
foundation
MRk,s = 0.24 [kN*m] Characteristic bending resistance of an anchor CEB [9.3.2.2]
lsm = 73 [mm] Lever arm length CEB [9.3.2.2]
gMs = 1.20 Partial safety factor CEB [3.2.3.2]
Fv,Rd,sm = aM*MRk,s/(lsm*gMs)
Fv,Rd,sm = 5.54 [kN] Shear resistance of a bolt - with lever arm CEB [9.3.1]
CONCRETE PRY-OUT FAILURE
NRk,c = 25.50 [kN] Design uplift capacity CEB [9.2.4]
k3 = 2.00 Factor related to the anchor length CEB [9.3.3]
gMc = 2.16 Partial safety factor CEB [3.2.3.1]
Fv,Rd,cp = k3*NRk,c/gMc
Fv,Rd,cp = 23.61 [kN] Concrete resistance for pry-out failure CEB [9.3.1]
CONCRETE EDGE FAILURE
Shear force Vj,Ed,y
VRk,c,y0 132. [k CEB [9.3.4.
= 80 N] Characteristic resistance of an anchor (a)]
yA,V,y = 0.67 Factor related to anchor spacing and edge distance CEB [9.3.4]
CEB [9.3.4.
yh,V,y = 1.00 Factor related to the foundation thickness
(c)]
CEB [9.3.4.
ys,V,y = 0.90 Factor related to the influence of edges parallel to the shear load direction
(d)]
yec,V,y 1.00 Factor taking account a group effect when different shear loads are acting on the CEB [9.3.4.
= individual anchors in a group (e)]
CEB [9.3.4.
ya,V,y = 1.00 Factor related to the angle at which the shear load is applied
(f)]
yucr,V,y 1.00 CEB [9.3.4.
Factor related to the type of edge reinforcement used
= (g)]
CEB
gMc = 2.16 Partial safety factor
[3.2.3.1]
Fv,Rd,c,y = VRk,c,y0*yA,V,y*yh,V,y*ys,V,y*yec,V,y*ya,V,y*yucr,V,y/gMc
Fv,Rd,c,y = 36.89 [kN] Concrete resistance for edge failure CEB [9.3.1]
Shear force Vj,Ed,z
VRk,c,z0 132. [k CEB [9.3.4.
= 80 N] Characteristic resistance of an anchor (a)]
yA,V,z = 0.67 Factor related to anchor spacing and edge distance CEB [9.3.4]
CEB [9.3.4.
yh,V,z = 1.00 Factor related to the foundation thickness
(c)]
CEB [9.3.4.
ys,V,z = 0.90 Factor related to the influence of edges parallel to the shear load direction
(d)]
yec,V,z 1.00 Factor taking account a group effect when different shear loads are acting on the CEB [9.3.4.
Shear force Vj,Ed,z
VRk,c,z0 132. [k CEB [9.3.4.
= 80 N] Characteristic resistance of an anchor (a)]
= individual anchors in a group (e)]
CEB [9.3.4.
ya,V,z = 1.00 Factor related to the angle at which the shear load is applied
(f)]
yucr,V,z 1.00 CEB [9.3.4.
Factor related to the type of edge reinforcement used
= (g)]
CEB
gMc = 2.16 Partial safety factor
[3.2.3.1]
0
Fv,Rd,c,z = VRk,c,z *yA,V,z*yh,V,z*ys,V,z*yec,V,z*ya,V,z*yucr,V,z/gMc
Fv,Rd,c,z = 36.89 [kN] Concrete resistance for edge failure CEB [9.3.1]
SPLITTING RESISTANCE
0.30 Coeff. of friction between the base plate and
Cf,d = [6.2.2.(6)]
concrete
Nc,Ed = 23.81 [kN] Compressive force [6.2.2.(6)]
Ff,Rd = Cf,d*Nc,Ed
Ff,Rd = 7.14 [kN] Slip resistance [6.2.2.(6)]
SHEAR CHECK
Vj,Rd,y = nb*min(F1,vb,Rd,y, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,y) + Ff,Rd
Vj,Rd,y = 73.65 [kN] Connection resistance for shear CEB [9.3.1]
Vj,Ed,y / Vj,Rd,y ≤ 1,0 0.01 < 1.00 verified (0.01)
Vj,Rd,z = nb*min(F1,vb,Rd,z, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,z) + Ff,Rd
Vj,Rd,z = 73.65 [kN] Connection resistance for shear CEB [9.3.1]
Vj,Ed,z / Vj,Rd,z ≤ 1,0 0.17 < 1.00 verified (0.17)
Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z ≤ 1,0 0.17 < 1.00 verified (0.17)

STIFFENER CHECK
Stiffener parallel to the web (along the extension of the column web)
M1 = 4.53 [kN*m] Bending moment acting on a stiffener
Q1 = 36.82 [kN] Shear force acting on a stiffener
zs = 79 [mm] Location of the neutral axis (from the plate base)
Is = 35549.48 [cm4] Moment of inertia of a stiffener
sd = 0.69 [MPa] Normal stress on the contact surface between stiffener and plate EN 1993-1-1:[6.2.1.(5)]
sg = 4.41 [MPa] Normal stress in upper fibers EN 1993-1-1:[6.2.1.(5)]
t= 4.60 [MPa] Tangent stress in a stiffener EN 1993-1-1:[6.2.1.(5)]
sz = 8.00 [MPa] Equivalent stress on the contact surface between stiffener and EN 1993-1-1:[6.2.1.(5)]
plate
max (sg, t / (0.58), sz ) / (fyp/gM0) ≤ 1.0 (6.1) 0.03 < 1.00 verified (0.03)
Stiffener perpendicular to the web (at the midpoint of the column web height)
M1 = 7.36 [kN*m] Bending moment acting on a stiffener
Q1 = 42.78 [kN] Shear force acting on a stiffener
zs = 161 [mm] Location of the neutral axis (from the plate base)
Is = 21514.10 [cm4] Moment of inertia of a stiffener
sd = 4.66 [MPa] Normal stress on the contact surface between stiffener and plate EN 1993-1-1:[6.2.1.(5)]
sg = 9.02 [MPa] Normal stress in upper fibers EN 1993-1-1:[6.2.1.(5)]
t= 5.35 [MPa] Tangent stress in a stiffener EN 1993-1-1:[6.2.1.(5)]
sz = 10.37 [MPa] Equivalent stress on the contact surface between stiffener and EN 1993-1-1:[6.2.1.(5)]
plate
max (sg, t / (0.58), sz ) / (fyp/gM0) ≤ 1.0 (6.1) 0.04 < 1.00 verified (0.04)
WELDS BETWEEN THE COLUMN AND THE BASE PLATE
s^ = 2.72 [MPa] Normal stress in a weld [4.5.3.(7)]
t^ = 2.72 [MPa] Perpendicular tangent stress [4.5.3.(7)]
tyII = 0.02 [MPa] Tangent stress parallel to Vj,Ed,y [4.5.3.(7)]
tzII = -0.75 [MPa] Tangent stress parallel to Vj,Ed,z [4.5.3.(7)]
bW = 0.80 Resistance-dependent coefficient [4.5.3.(7)]
s^ / (0.9*fu/gM2)) ≤ 1.0 (4.1) 0.01 < 1.00 verified (0.01)
Ö(s^ + 3.0 (tyII + t^ )) / (fu/(bW*gM2))) ≤ 1.0 (4.1) 0.02 < 1.00
2 2 2
verified (0.02)
Ö(s^2 + 3.0 (tzII2 + t^2)) / (fu/(bW*gM2))) ≤ 1.0 (4.1) 0.01 < 1.00 verified (0.01)

VERTICAL WELDS OF STIFFENERS


Stiffener parallel to the web (along the extension of the column web)
s^ = 5.00 [MPa] Normal stress in a weld [4.5.3.(7)]
t^ = 5.00 [MPa] Perpendicular tangent stress [4.5.3.(7)]
tII = 3.84 [MPa] Parallel tangent stress [4.5.3.(7)]
sz = 12.01 [MPa] Total equivalent stress [4.5.3.(7)]
bW = 0.80 Resistance-dependent coefficient [4.5.3.(7)]
max (s^, tII * Ö3, sz) / (fu/(bW*gM2)) ≤ 1.0 (4.1) 0.03 < 1.00 verified (0.03)
Stiffener perpendicular to the web (at the midpoint of the column web height)
s^ = 8.13 [MPa] Normal stress in a weld [4.5.3.(7)]
t^ = 8.13 [MPa] Perpendicular tangent stress [4.5.3.(7)]
tII = 4.46 [MPa] Parallel tangent stress [4.5.3.(7)]
sz = 18.00 [MPa] Total equivalent stress [4.5.3.(7)]
bW = 0.80 Resistance-dependent coefficient [4.5.3.(7)]
max (s^, tII * Ö3, sz) / (fu/(bW*gM2)) ≤ 1.0 (4.1) 0.05 < 1.00 verified (0.05)

TRANSVERSAL WELDS OF STIFFENERS


Stiffener parallel to the web (along the extension of the column web)
s^ = 5.34 [MPa] Normal stress in a weld [4.5.3.(7)]
t^ = 5.34 [MPa] Perpendicular tangent stress [4.5.3.(7)]
tII = 5.05 [MPa] Parallel tangent stress [4.5.3.(7)]
sz = 13.81 [MPa] Total equivalent stress [4.5.3.(7)]
bW = 0.80 Resistance-dependent coefficient [4.5.3.(7)]
max (s^, tII * Ö3, sz) / (fu/(bW*gM2)) ≤ 1.0 (4.1) 0.04 < 1.00 verified (0.04)
Stiffener perpendicular to the web (at the midpoint of the column web height)
s^ = 3.66 [MPa] Normal stress in a weld [4.5.3.(7)]
t^ = 3.66 [MPa] Perpendicular tangent stress [4.5.3.(7)]
tII = 3.47 [MPa] Parallel tangent stress [4.5.3.(7)]
sz = 9.48 [MPa] Total equivalent stress [4.5.3.(7)]
bW = 0.80 Resistance-dependent coefficient [4.5.3.(7)]
max (s^, tII * Ö3, sz) / (fu/(bW*gM2)) ≤ 1.0 (4.1) 0.03 < 1.00 verified (0.03)

CONNECTION STIFFNESS
Bending moment Mj,Ed,y
beff = 125 [mm] Effective width of the bearing pressure zone under the flange [6.2.5.(3)]
Effective length of the bearing pressure zone under the
leff = 415 [mm] [6.2.5.(3)]
flange
k13,y = Ec*Ö(beff*leff)/(1.275*E)
k13,y = 23 [mm] Stiffness coeff. of compressed concrete [Table 6.11]
leff = 417 [mm] Effective length for a single bolt for mode 1 [6.2.6.5]
m= 66 [mm] Distance of a bolt from the stiffening edge [6.2.6.5]
k15,y = 0.425*leff*tp3/(m3)
k15,y = 9 [mm] Stiffness coeff. of the base plate subjected to [Table 6.11]
tension
Lb = 255 [mm] Effective anchorage depth [Table 6.11]
k16,y = 1.6*Ab/Lb
k16,y = 2 [mm] Stiffness coeff. of an anchor subjected to [Table 6.11]
tension
l0,y = 0.64 Column slenderness [5.2.2.5.(2)]
Sj,ini,y = 39909.02 [kN*m] Initial rotational stiffness [Table 6.12]
Sj,rig,y = 137923.29 [kN*m] Stiffness of a rigid connection [5.2.2.5]
Sj,ini,y < Sj,rig,y SEMI-RIGID [5.2.2.5.(2)]
Bending moment Mj,Ed,z
k13,z = Ec*Ö(Ac,z)/(1.275*E)
k13,z = 27 [mm] Stiffness coeff. of compressed concrete [Table 6.11]
leff = 353 [mm] Effective length for a single bolt for mode 2 [6.2.6.5]
m= 70 [mm] Distance of a bolt from the stiffening edge [6.2.6.5]
k15,z = 0.425*leff*tp3/(m3)
k15,z = 7 [mm] Stiffness coeff. of the base plate subjected to [Table 6.11]
tension
Lb = 255 [mm] Effective anchorage depth [Table 6.11]
k16,z = 1.6*Ab/Lb
k16,z = 2 [mm] Stiffness coeff. of an anchor subjected to [Table 6.11]
tension
l0,z = 1.12 Column slenderness [5.2.2.5.(2)]
Sj,ini,z = 108108.93 [kN*m] Initial rotational stiffness [6.3.1.(4)]
Sj,rig,z = 45049.50 [kN*m] Stiffness of a rigid connection [5.2.2.5]
Sj,ini,z ³ Sj,rig,z RIGID [5.2.2.5.(2)]

WEAKEST COMPONENT:
FOUNDATION - CONCRETE CONE PULL-OUT FAILURE

REMARKS
Anchor curvature radius is too small. 50 [mm] < 60 [mm]
Segment L4 of the hook anchor is too 0 [mm] < 100 [mm]
short.
 
 

Connection conforms to the code Ratio 0.79