MRT-I MRT-II

The best route to total comfort.


Rooftop coach air conditioning systems.

Environmental Control For Transportation


• Environmental control means total control of • Low profile design minimizes additional coach/bus
temperature, humidity, ventilation and air circulation height to enhance vehicle appearance
• Featuring the IntelligAIRE® Control System and • While low profile, this system maintains
optional Smart Controller® diagnostic system Thermo King’s reputation for high performance and
low maintenance costs
MRT-I and MRT-II Specifications
DESCRIPTION COMPRESSORS
The MRT-I/II is a rooftop system designed for • Thermo King Model X426
cool or cool/heat applications. The low-profile • TM-16 Dual Compressor option available using two Worldwide Service Organization
system is designed to blend into bus designs to compressors where compressor space is limited. Thermo King backs its equipment and
enhance vehicle appearance. Design configuration Performance with dual compressors per following: customers with a highly-trained, worldwide
enables either the unit to be installed anywhere on service organization. This assures you the
the roof of the bus for maximum flexibility and weight Maximum Capacity:
BTU/hr kW Kcal/hr support of factory authorized service
distribution. Available with 5M, 7.5M, or 11.5M radius facilities and a stock of factory parts and
base to better conform to bus roof radius. 73,500 21.5 18,500
Rated Capacities: factory trained mechanics.
CONTROLS BTU/hr kW Kcal/hr
The IntelligAIRE® Control System provides the driver 60,000 17.5 15,120
simple, but total control of the vehicle’s internal ELECTRIC POWER REQUIREMENTS Warranty
environment. Provided also is safety shutdown with • 72 amps at 24V dc
red light indication. Terms of the Thermo King Warranty are available
The optional Smart Controller® diagnostic feature WEIGHT (approximate) on request from your local Thermo King dealer.
provides compressor and system hourmeters for MRT-I-1000 212 kg (467 lbs) Please reference document TK50049 for the
precise preventative maintenance. System shuts MRT-II-1000 226 kg (498 lbs) Thermo King Bus Unit Warranty.
down to prevent costly failure – yellow alarm MRT-I-1004 224 kg (494 lbs)
indicator and a record of alarm codes to aid in MRT-II-1004 238 kg (525 lbs)
troubleshooting and repair. Compressor 52 kg (115 lbs)

SYSTEM COOLING CAPACITY DIMENSIONS millimeters (inches)


Maximum Capacity:
BTU/hr kW Kcal/hr 3426
104,700 30.7 23,200 (134.9")
Rated Capacities: 186 1535 1350 355 85.4
(7.32") (60.4") (53.1") (14") (3.36")
BTU/hr kW Kcal/hr
72,400 21.2 18,300 R 5000
Rated capacities are at following conditions: (196.9")
MRT-I

Outside 35°C/95°F
Inside 27°C/80°F DB 1828.8 177.8
19°C/67°F WB (72") (7")

SYSTEM HEATING CAPACITY


R 7500
At 30 Lt. /Min.(8 GPM) coolant flow rate and (295.3")
55K (100°F) temperature differential between
return air and coolant. 63.3
(2.5")
BTU/hr kW Kcal/hr
89,500 26.2 22,500 3426
(134.9") 75.6
EVAPORATOR AIRFLOW 186 1535 1350 355 57.4 (3")
(0 mm (0 in.) water column external static pressure) (7.32") (60.4") (53.1") (14") (2.26")
High Speed 3,500 m3/hr (2100 ft3/min)
Medium Speed 2,300 m3/hr (1400 ft3/min) R 7500
(295.3")
Low Speed 1,500 m3/hr ( 900 ft3/min) R 11500
MRT-II

(452.75")
REFRIGERANT 2106 177.8 177.8
• HFC R-134a (82.9") (7") (7")

R 5000
(196.9")

113.5
(4.47")

Thermo King Thermo King Thermo King Thermo King Thermo King
World Headquarters Asia Pacific do Brasil Europe Europe
Minneapolis, MN U.S.A. Hong Kong, PRC Campinas, Brasil Brussels, Belgium Kolin, Czech Republic
Tele: +1 952 887 2200 Tele: +852 2507 9100 Tele: +55 19 745 6400 Tele: +32 2 7145711 Tele: +420 321 757111