Digital Video Archiving Software

EZU-DV4

INSTRUCTION MANUAL

Special Notes to Operators and Maintenance Managers

★ Before using this system, be sure to thoroughly read this manual and make yourself
familiar with this system.
★ After reading this manual, keep it in an easily accessible place close to the system.

Tokyo, Japan

Q1E-EZ1204-9

Copyright © Hitachi Medical Corporation. 2009 - 2014. All rights reserved.


This manual explains how to configure the Digital Video Archiving Software and operate the
equipment safely and correctly.

Conventions used in this manual:


Alphanumeric keyboard (option) keys and dialog box buttons are shown in bold letters.
Examples: : Del key, : OK button

Symbols used in this manual:


This symbol indicates an immediate danger that could result in death or serious
injury of personnel, total destruction of equipment, or fire if the warning is
ignored and the equipment is handled incorrectly.

This symbol indicates a potential (latent) danger that could result in death or
serious injury of personnel, total destruction of equipment, or fire if the warning
is ignored and the equipment is handled incorrectly. The following is an
example of a potential danger:
(Ex.) Failure to observe this warning could result in death if the cover is opened
and a high-voltage terminal is touched.

This symbol indicates possible danger that could result in light or moderate
injury of personnel, partial equipment damage, or deletion of computer data if
the warning is ignored and the equipment is handled incorrectly.

This symbol indicates prohibited conditions or actions. The description


accompanying this symbol indicates conditions or actions that are prohibited.

This symbol indicates precautions to be observed. The description


accompanying this symbol indicates conditions that require careful attention or
that might be dangerous.

This symbol indicates a recommended procedure, condition, or action that


requires careful attention when operating the equipment.

This symbol indicates supplementary information.

Cautions on exportation:
When exporting this equipment, be sure to check the Foreign Exchange and Foreign
Trade Control Law and the regulations related to export control in the United States of
America, and perform the necessary procedures.
Contact Hitachi or an authorized representative if you have further inquiries.
Revision history:
First edition: November 2009
Eighth edition: April 2013
Ninth edition: April 2014
Introduction
Thank you for purchasing the “Digital Video Archiving Software ”.
To use this software safely and correctly, it is essential to have a full understanding of its
functions, operation. Read this instruction manual thoroughly before using this software.
To use this software, Digital capture card unit is required.

About the ultrasound diagnostic scanner windows


Note that the ultrasound diagnostic scanner windows referred to in this instruction manual
might differ from the windows actually displayed.

About the separate INSTRUCTION MANUAL HI VISION Avius


Preparation
The separate INSTRUCTION MANUAL HI VISION Avius Preparation contains important
notes on safely using the equipment, etc.
Before you use the equipment, make sure that you read the separate INSTRUCTION
MANUAL HI VISION Avius Preparation.
The separate INSTRUCTION MANUAL HI VISION Avius Preparation also lists the
principal messages that are displayed in windows. Refer to the separate INSTRUCTION
MANUAL HI VISION Avius Preparation as necessary for the messages.

About basic use the equipment


The separate INSTRUCTION MANUAL HI VISION Avius Operation contains important
notes on safely using the equipment.
Refer to the chapter Configuration of the Examination Window, and the chapter How to
Operate the Ultrasound Diagnostic Scanner in the separate INSTRUCTION MANUAL HI
VISION Avius Operation before using the equipment.

Q1E-EZ1204 i
ii Q1E-EZ1204
Contents
Introduction................................................................................................................................................i

Contents .................................................................................................................................................. iii

Chapter 1 - Outline.............................................................. 1
1.1 Purpose of use ...................................................................................................................................1

1.2 Cautions .............................................................................................................................................1

1.2.1 General ................................................................................................................................................1

1.2.2 Long time recording mode...................................................................................................................2

1.3 Features .............................................................................................................................................3

1.3.1 Clip capture mode................................................................................................................................3

1.3.2 Long time recording mode...................................................................................................................3

Chapter 2 - Software Components and Installation ............ 5


2.1 Standard Components........................................................................................................................5

2.2 Installation ..........................................................................................................................................5

2.3 Optional components .........................................................................................................................5

Chapter 3 - Clip capture mode............................................ 7


3.1 Outline of Clip capture mode..............................................................................................................7

3.2 Setting of capture condition................................................................................................................7

3.2.1 Preset ...................................................................................................................................................8

3.2.2 Real-time .............................................................................................................................................8

3.2.3 Freeze ..................................................................................................................................................9

3.2.4 Common ............................................................................................................................................11

3.2.5 General ..............................................................................................................................................12

3.3 Selection of preset by application ....................................................................................................13

3.4 Setting of the capture condition temporarily.....................................................................................14

Q1E-EZ1204 iii
3.4.1 Setup Filing screen............................................................................................................................ 14

3.5 Capture............................................................................................................................................ 15

3.5.1 Real-time........................................................................................................................................... 15

3.5.2 Freeze................................................................................................................................................ 17

3.6 Playback .......................................................................................................................................... 18

3.6.1 Clip Information ............................................................................................................................... 19

3.6.2 Screen buttons of single image playback .......................................................................................... 19

3.6.3 Screen buttons of multi image playback ........................................................................................... 21

Chapter 4 - Long time recording mode..............................23


4.1 Outline of Long time recording mode .............................................................................................. 23

4.1.1 Outline .............................................................................................................................................. 23

4.1.2 Restriction during long time recording ............................................................................................. 23

4.2 Setting of start/stop recording.......................................................................................................... 24

4.3 Setting of record condition............................................................................................................... 25

4.4 Setting of the record condition temporarily...................................................................................... 28

4.5 Record ............................................................................................................................................. 29

4.6 Playback .......................................................................................................................................... 30

4.6.1 Video-clip information...................................................................................................................... 32

4.6.2 Screen buttons of single image playback .......................................................................................... 32

4.6.3 Screen buttons of multi image playback ........................................................................................... 34

4.7 Playback with Comparison window ................................................................................................. 35

4.8 Video-clips with Recording Errors ................................................................................................... 35

Chapter 5 - Specifications..................................................37
5.1 Clip capture mode ........................................................................................................................... 37

5.1.1 Common ........................................................................................................................................... 37

5.1.2 Real-time........................................................................................................................................... 37

5.1.3 Freeze on........................................................................................................................................... 38

5.2 Long time recording mode............................................................................................................... 39

iv Q1E-EZ1204
Appendix A - Playback Clips with PC................................ 41
A.1 Playback with Windows ...................................................................................................................41

Appendix B - Compress Rate of Clips .............................. 47


B.1 Compress rate and formula of file size ............................................................................................47

B.2 Example of calculation.....................................................................................................................47

INDEX ............................................................................... 49

Q1E-EZ1204 v
vi Q1E-EZ1204
Chapter 1 - Outline

Chapter 1 - Outline
1.1 Purpose of use
This Digital Video Archiving Software captures real-time clips displayed on ultrasound
diagnostic scanner.

1.2 Cautions
1.2.1 General·····································································································
z Hitachi bears no responsibility for data loss due to unexpected accidents, malfunction, or
incorrect operation. Be sure to make backups of important data.
z When capturing important data, be sure to perform a test capture in advance to confirm
that capturing works correctly.
z Clips that are compressed and captured with the digital video archiving software will
show degradation in image quality. Use this software only to the extent that degradation
will not affect diagnoses.
z Do not turn off the breaker switches while capturing clips.
Turning off the breaker switches while capturing clips might result in damage to drives,
disks, and the content of disks.

While capturing clips, the scanner will not shut down even if you press the
ON/STANDBY key .
To shut down the scanner, first make sure that the capturing of clips is complete, and
then set the ON/STANDBY key to OFF.

z Any changes made to DGA or BSA while playing back clips will not change the DGA or
BSA that appear in the recorded scene.
When taking measurements that are affected by values such as DGA and BSA, check the
values that are displayed in the dialog box for entering patient menu or the Measurement
Report, as necessary.
z The scene where image popup and a dialog box were displayed on ultrasound image is
recorded, but please do not measure it in what become the false measurement.
z Make sure that the drive access lamp is off before performing the following operations.
Performing the following operations while the access lamp is on or flashing might result
in damage to drives, disks, and the content of disks.
ƒ Pressing the ON/STANDBY key
ƒ Pressing the EJECT key EJECT

Q1E-EZ1204 1
Chapter 1 - Outline

ƒ Pressing the eject button for the DVD MULTI drive

Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or manipulate the
record files. And the clips captured by other model Ultrasound Diagnostic Scanner
(For example EUB Series, HI VISION 900) cannot be played back and operated on
HI VISION Avius.

1.2.2 Long time recording mode ········································································


z You can use DVD-RAM or USB HDD (external media for recording) when you perform
recording in long time recording mode. Be sure to use the recommended media.
z For capturing, the save destination storage device to be used needs to have at least 300
MB of space available.
Use the storage device that has sufficient available space.

y For details about DVD-RAM Media, see the chapter Recommended media/Drive
and Handling of a DVD-RAM/DVD-R Media in the separate INSTRUCTION
MANUAL HI VISION Avius Preparation.
y Recording errors are more likely to occur if you partition the capture region on
DVD-RAM media. Therefore, do not use DVD-RAM media that you have
repeatedly used to save and delete images for recording.
However, if you do use DVD-RAM media that you have repeatedly used to save
and delete images, be sure to first delete all images from the DVD-RAM media
before performing recording in long time recording mode.

2 Q1E-EZ1204
Chapter 1 - Outline

1.3 Features
This digital video archiving software captures real-time clips as high quality digital images.
Both the clip capture mode and long time recording mode are available for capturing.
1.3.1 Clip capture mode ····················································································
z You can record videos in uncompressed format or Motion JPEG Format.
z You can capture every heartbeat, with the use of an optional biomedical waveform
display unit.
z You can set 8 types of capture conditions, and also set in advance the conditions to be
used for each diagnostic region.
z You can perform high-speed capturing of continuous frame images in cine memory when
freeze occurs.
z Clips are compatible with AVI and DICOM formats.
z You can perform clip analyses, such as measurements and tracking, on captured clips.
1.3.2 Long time recording mode········································································
z You can record videos of examinations in MPEG-2 format.
z You can record direct to DVD-RAM media or USB HDD.
z You can transfer single images while recording.
z You can record and play back the captured Doppler sound along with diagnostic images.
z You can take measurements on recorded clips.
z You can specify settings for adding chapters according to the scenes that you are
recording.

y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y In this instruction manual, “clip” means the multi image that captured by clip
capture mode, and “video-clip” means the multi image that captured by long
time recording mode.

Q1E-EZ1204 3
Chapter 1 - Outline

4 Q1E-EZ1204
Chapter 2 - Software Components and Installation

Chapter 2 - Software Components and


Installation
2.1 Standard Components
(1) Instruction Manual 1 set

(2) MPEG-2 Decoder Installation CD 1 disk

The MPEG-2 decoder software recorded on MPEG-2 Decoder Installation CD can not
be installed in PC.

2.2 Installation
This software is installed and used in the equipment.
This software is installed at the time of shipment from manufacturer.
Or, it maybe installed to your equipment which has been using, by the server of our corporation
or appointed by our corporation.

Except the servers who have been educated by our corporation, please DO NOT
disassemble or rebuild the equipment.

2.3 Optional components


z In case of capturing clip by the heart beat, the Biomedical waveform display unit
(EZU-EK28) is required.
z In order to use the DICOM transfer with clip capture mode, the DICOM Software
(Transfer and Media Storage)(EZU-FC11) is required.
z In order to use the Foot Switch (for Freeze/User Define), the EZU-FS2 is required.

Q1E-EZ1204 5
Chapter 2 - Software Components and Installation

6 Q1E-EZ1204
Chapter 3 - Clip capture mode

Chapter 3 - Clip capture mode


3.1 Outline of Clip capture mode
(1) Capture clip at real time can be executed with freeze off.

(2) Capture clip from cine memory can be executed with freeze on.

(3) Capture clip is executed with the capture condition that has been set beforehand.

3.2 Setting of capture condition


Display Setup Filing dialog box in Tab Menu→Setup→Filing and Select a preset item on
Record Multi Image.
Setup Filing (Recording Multi Image) is displayed as Figure 3.2-1.
Please set the capture condition as following. After setting, select the OK button to make the
change available. Select the Cancel button to make the change will not be available.

Figure 3.2-1 Menu of Setup Filing (Recording Multi Image)

It is not possible to select some capture conditions when the Digital Capture Card is
not connected or has a trouble. In this case, please call Service.

Q1E-EZ1204 7
Chapter 3 - Clip capture mode

3.2.1 Preset ·······································································································


It is possible to select Preset to edit.
For details, see the subsection Recording Multi Image in the chapter Filing Function in the
separate INSTRUCTION MANUAL HI VISION Avius Operation.
Please refer to "3.3 Selection of preset by application" about choosing preset by application.
3.2.2 Real-time ··································································································
■ Image Format
Select the image format for clips at the time of real time. You can select AVI
[uncompressed] or AVIm [Motion JPEG compression]. You can also select DICOM or
DICOM JPEG (Lossy) if the optional DICOM Software (Transfer and Media Storage) is
installed.

■ Mode
Transfer Mode at the time of real time can be chosen.

(1) Free
Capture until the set time (second(s)) elapses.
Please set the record time in "Capture Time".
And, please select the Capture Rate from the combo box.
Capture Rate can be chosen from the following values.
30, 20, 15, 10, 8, 6 Fr/s
When the capture starts, it will end automatically after the time which has been set
elapses and produce the captured clip.

y “Interval” and “Capture Rate” can be changed when “Free” is chosen.


It is not displayed in “R trigger” mode.
y The max time of once record is different according to the Capture Rate. (For
details, please refer to Capture time in "5.1.2 Real-time".)

8 Q1E-EZ1204
Chapter 3 - Clip capture mode

(2) R trigger
The frame during the chosen R-wave trigger is captured as one file.
Please set the heartbeat in "Number".
For one file, 10 heartbeats(beat) is the maximum that in which it can be captured.
The time of capture is calculated automatically with the heart rate when capture starts
and the heartbeat which has been set.
After the capture starts, capture finishes automatically when the
automatically-calculated-time elapses, and then the captured clip is archived.
From this clip, images are taken out and the amount is decided to the heartbeat which
has been set.

Number is displayed only when R trigger is chosen. It is not displayed in "Free" or


"Beat Duration" mode.

3.2.3 Freeze ······································································································


■ Image Format
Select the image format for clips at the time of freeze. You can select from AVI
[uncompressed], AVI (Compression) [Microsoft Video1 compression], or AVIm [Motion
JPEG compression]. You can also select DICOM or DICOM JPEG (Lossy) if the optional
DICOM Software (Transfer and Media Storage) is installed.
When AVIm [Motion JPEG compression] or DICOM JPEG (Lossy) is selected, digital
video archiving software functions are used for high-speed recording.

y When a collectively transferring images sets at the time of DICOM selection, it


saves in DICOM at a hard disk (DICOM). When a collectively transferring
images sets at the time of DICOM JPEG (Lossy) selection, it saves in DICOM
JPEG (Lossy) at a hard disk (DICOM).
y When a transfer error occurs at the time of DICOM selection, it saves in DICOM
at a hard disk (DICOM). When a transfer error occurs at the time of DICOM
JPEG (Lossy) selection, it saves in DICOM JPEG (Lossy) at a hard disk
(DICOM).
Please transfer from Filing window, after solving the problem of transferring.

Q1E-EZ1204 9
Chapter 3 - Clip capture mode

■ Mode
Transfer Mode at the time of freeze can be chosen.

(1) F-Fout
This is to record a series of continued frames selected in discretion as one file. The
number of frames chosen when “Auto” was chosen by the Range is recorded.
ALL, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100
You can select the starting frame and ending frame for producing Multi Images when
“Manual” was chosen by the Range. After REC key and User pedal of Foot
SW(Option) assigned Record Multi Image is pressed, Multi Images are produced
following to messages.

(2) R-Rout
This is to record a series of frames in R-wave time phase selected in discretion as one
file. The number of heartbeats chosen when “Auto” was chosen by the Range is
recorded.
ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
You can select the starting R-wave frame and ending R-wave frame for producing
Multi Images when “Manual” was chosen by the Range. After Rec key and User
pedal of Foot SW(Option) assigned Record Multi Image is pressed, Multi Images are
produced following to message.

(3) ALL
This is to record all the cine image as one file.
Range and Number are not displayed.

10 Q1E-EZ1204
Chapter 3 - Clip capture mode

3.2.4 Common···································································································
■ Compression
The compression level at the time of capturing in AVIm [Motion JPEG compression] can
be chosen.
Please choose one from the Compression combo box.
y Standard Capture clip with the balance of quality and size.

y High-Compression Capture clip with small size.


If quality is the priority, please choose other level.

Compression Level Image Quality File Size

Standard High Big

High-Compression Low Small

y For analysis, use clips that were captured both by using AVI [uncompressed] and
after freezing the image.
Using clips captured by using AVIm [Motion JPEG compression] or clips
captured in real time might result in reduced analytical precision.
y Since the digital video archiving software compresses image data, there might be
a change in color in the display of fine lines.

Q1E-EZ1204 11
Chapter 3 - Clip capture mode

3.2.5 General·····································································································
■ Destination in Freeze
On the Setup Filing screen, select Record Multi Image and then General. Only the drives
that can be selected as a save destination for clips at the time of freeze are displayed in
the menu. Select the check box for the drive you want to select as the save destination.

Figure 3.2-2 Destination in Freeze

y For details, see the subsection Recording Multi Image in the chapter Filing
Function in the separate INSTRUCTION MANUAL HI VISION Avius Operation.
y The setting of [Recording] → [General] → [Freeze] can not be used when the
setting of [Common] → [Destination] → [Use the data destination as a
common setting] is ON.

12 Q1E-EZ1204
Chapter 3 - Clip capture mode

3.3 Selection of preset by application


The preset that is used in application can be selected in Region Data Setting. For details about
Region Data Setting, see the subsection Region Data Setting in the chapter Tab menus in the
separate INSTRUCTION MANUAL HI VISION Avius Operation. For details about Preset, see
the subsection Recording Multi Image in the chapter Filing Function in the separate
INSTRUCTION MANUAL HI VISION Avius Operation.
Preset is selected on Image Filing in Region Data Setting menu.

Figure 3.3-1 Region Data Setting Image Filing tab

Image Filing M-Write


Please choose a preset in the current application from the combo box.
Display the setting information of selected preset under the combo box.

Q1E-EZ1204 13
Chapter 3 - Clip capture mode

3.4 Setting of the capture condition temporarily


3.4.1 Setup Filing screen ···················································································
The capture condition can be changed temporarily from the Tab Menu → [Tool] → [Filing].
The changed setting of capture condition is held until the following operations are performed.
z Turn off the power of equipment
z Set again in the Tab Menu → [Setup] → Filling
z Change the application
Please refer to "3.2 Setting of capture condition" about the "Image Filing".
The setting is applied in capturing after OK is pressed.
Moreover, unlike "3.2 Setting of capture condition", on this screen, capturing is performed by
condition of preset when clicking OK.
Please refer to "3.2 Setting of capture condition" about configuration of the items.

Figure 3.4-1 Setup Filing screen

It is not possible to select some capture conditions when the Digital Capture Card is
not connected or has a trouble. In this case, please call Service.

14 Q1E-EZ1204
Chapter 3 - Clip capture mode

3.5 Capture
3.5.1 Real-time ··································································································
(1) Starting capture
Press the Rec key and User pedal of Foot SW(Option) that assigned Recording Multi
Image at the time of real time, the ultrasound images then will be captured with real-time.
When the capture starts, the elapsed time and record time will be displayed bottom left of
cine bar.
During capturing, “Recording” is displayed on progress bar in System information
display area.

Cine memory
playback bar

System information
display area

Figure 3.5-1 Cine memory playback bar, System information display area

Progress bar

Figure 3.5-2 Progress bar

Q1E-EZ1204 15
Chapter 3 - Clip capture mode

y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y The next record operation (clip and image) and the Filing operation cannot be
performed during transferring the captured clip.
y When the pointer is displayed while image is capturing, the pointer is recorded in
the image.

(2) Stopping capture


Capturing will stop as below case.
ƒ When press the Rec key assigned Record Multi Image.
ƒ When turn the Freeze key FREEZE ON.
ƒ When use the Three-dimensional display unit (Real-Time)(option) function.
ƒ When change the probe.
ƒ When the following operations are done while recording in "R trigger" mode.#
・ Mode select (B, Color, M, Doppler) operation
・ Image select (DUAL/SINGLE, L/(U), R/(D) ) operation
・ Image condition change operation

During capturing end processing, it is displayed “Terminating” on progress bar in System


information display area.

# In this case, playback image motion may be slower than at the time of a record.

16 Q1E-EZ1204
Chapter 3 - Clip capture mode

3.5.2 Freeze ······································································································


(1) Starting capture
Press the Rec key and User pedal of Foot SW(Option) assigned Record Multi Image at
the time of freeze, the continuation frame of the cine memory images at the time is
transmitted as a clip.
Display “Creating” on progress bar in System information display area during a multi
image is created in Freeze.

Clip capture mode and Long time recording mode cannot be used at the same time.
When you are recording one mode and start the other recording mode, it is necessary
to stop recording.

(2) Canceling capture


Capturing will be canceled as below case.
ƒ When press the Rec key and User pedal of Foot SW(Option) Record Multi Image
or UNDO key . UNDO

When canceling capturing, hold down key until capturing is canceled.


Capturing may not be canceled in case of the key is not held down long enough.

(3) Stopping capture


When all frames are captured, it is displayed “Terminating” on progress bar in System
information display area.

Q1E-EZ1204 17
Chapter 3 - Clip capture mode

3.6 Playback
Captured clip can be played back using the following procedure, in the same way as is normally
done for single and multi images.

1 When Freeze is switched on, press the READ key READ


to open the
filing screen.
For details, see the chapter Filing Function in the separate INSTRUCTION MANUAL HI
VISION Avius Operation.

2 Select the clip data ( mark display) from the thumbnails.

Thumbnail

Figure 3.6-1 Filing dialog box

3 Press the Retrieve button.

18 Q1E-EZ1204
Chapter 3 - Clip capture mode

y Following measurement items are not compatible with measurements of review


image for clips.
Str. Ratio(Option), Str. Histo.(Option), D-Profile, Vascularity, Histogram,
CFM-Velo., MVG-M
y Following measurement item has the functional restrictions with measurements
of review image for clips.
- It is impossible to perform Real time Doppler measurement.
- The PISA measurement in MV Regurg and TV Regurg measurement is
impossible to calculate.
y Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or
manipulate the record files. And the clips captured by other model Ultrasound
Diagnostic Scanner (For example EUB Series, HI VISION 900) cannot be
played back and operated on HI VISION Avius.

3.6.1 Clip Information ························································································


When using single image display for a clip, the following clip information will appear on the
bottom right of the window.



①Current frame ②Total frame
No. 1 / 100 0:00:00 / 0:01:53
③Current time ④Total time

Figure 3.6-2 Clip information

3.6.2 Screen buttons of single image playback ·················································


When the clip that is captured by Clip capture mode is reviewed single image display, the screen
buttons at the bottom of the window change to the screen buttons for single image playback.
And If the File Operations button File Operations is pressed, the screen buttons change to the
screen buttons for file operation and file operation becomes possible. At this time, the buttons
that are shaded in gray in Figure 3.6-4 cannot be used.
# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End

Measurement Slideshow ■ Prev Page Next Page Division Chap List

Figure 3.6-3 Screen Buttons of Single Image Playback

# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End

Delete Trim ■ Prev Page Next Page Division Chap List

Figure 3.6-4 Screen Buttons of File Operation

Q1E-EZ1204 19
Chapter 3 - Clip capture mode

TIC : It is possible to execute TIC measurement on the Clip that


is captured by Clip capture mode. This button can not be
use when the Software Specified for Contrast Agents
(Option) is protected. Please refer to the separate
INSTUCTION MANUAL Software Specified for Contrast
Agents for TIC Measurement.

File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).

Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.

Trim : It is possible to create a new clip from selected frame. For


details, see the subsection Filing function screen buttons
in the chapter Filing Function in the separate
INSTRUCTION MANUAL HI VISION Avius Operation.

Chap Jump : It is possible to use this button when video-clip playback


is selected.

Speed : Used to change the playback speed by turning the screen


link encoder. Turn the encoder completely to the left for
-1x speed, and then increase the speed in the following
steps with each turn to the right: -1x, -1/2x, -1/4x, -1/8x,
0x, 1/8x, 1/4x, 1/2x, 1x.

Filing : Returns to the filing screen.

To Multi : Switches to multi image display when playing back


multiple images.

Select Start : It set the start frame for Trimming function.

Select End : It set the end frame for Trimming function.

Measurement : Switches to screen buttons for measurement. For details,


see the separate INSTUCTION MANUAL HI VISION
Avius Measurement.

Slide Show : Automatically moves from the currently displayed image


to display the next image. It is possible to use this when
multiple images are played and single image playback is
displayed.

■ (Stop) : Stops playback, fast-forward, and rewind.

20 Q1E-EZ1204
Chapter 3 - Clip capture mode


▼ (Play) : Plays the clip at normal speed.

Previous Page : Switches the window to the previous page.

Next Page : Switches the window to the next page.

Division : It divides a clip into Single Image. A maximum of 16


images can be displayed at the same time.

Chap List : It is possible to use this button when video-clip playback


is selected.

3.6.3 Screen buttons of multi image playback···················································


When using multi image display for a clip, the screen buttons at the bottom of the window
change to the screen buttons for clip multi-image playback. The same as for single image
playback, if the File Operations button File Operations is pressed, the screen buttons change to the
screen buttons for file operation and file operation becomes possible.

#
File Operations Speed Filing To Single

#
Measurement Images ■ Prev Page Next Page Division Chap List

Figure 3.6-5 Screen Buttons of Multi Image Playback for clip

File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).

Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.

Trim : It is possible to use this when clip single image playback


is displayed.

Speed : Used to change the playback speed by turning the screen


link encoder. Turn the encoder completely to the left for
-1x speed, and then increase the speed in the following
steps with each turn to the right: -1x, -1/2x, -1/4x, -1/8x,
0x, 1/8x, 1/4x, 1/2x, 1x.

Filing : Returns to the filing screen.

To Single : Switches the window display to single image display.

Measurement : It is possible to use this when single image playback is


displayed.

Q1E-EZ1204 21
Chapter 3 - Clip capture mode

Images : Used to change the number of images displayed on screen


by turning the screen link encoder. The number of images
displayed can be either 4, 9, or 16.

■ (Stop) : Stops playback, fast-forward, and rewind.


▼ (Play) : Plays the clip at normal speed.

Prev Page : Switches the window to the previous page.

Next Page : Switches the window to the next page.

Division : It divides a clip into Single Image. A maximum of 16


images can be displayed at the same time.

Chap List : It is possible to use this button when video-clip playback


is selected.

22 Q1E-EZ1204
Chapter 4 - Long time recording mode

Chapter 4 - Long time recording mode


4.1 Outline of Long time recording mode
4.1.1 Outline ······································································································
(1) Recording video clip can be executed in both states of Freeze ON, Freeze OFF.
(2) Recording video clip is executed with the recording condition that has been set
beforehand.
4.1.2 Restriction during long time recording ······················································
There are following restrictions during recording with the long time recording mode.

Table 4.1-1 Functional restrictions during long time recording


Function Restrictions

Digital Video Archiving Software Clip capture mode becomes unusable.

Filing function Both of the filing dialog box and the setup dialog box becomes
unusable.

Measurement function The filing dialog box becomes unusable.

Video/ORIG mode Function becomes unusable.


(VCR/DVD video recorder (Option) is
required)

Stress Echo Software (Option) Function becomes unusable.

WideView Software (Option) Function becomes unusable.

Logon Management Software (Option) Logon management function becomes unusable.

Entry Option Function becomes unusable.

Backup data Function becomes unusable.


In addition, there are following limitations during recording to DVD-RAM or USB HDD.

Q1E-EZ1204 23
Chapter 4 - Long time recording mode

Table 4.1-2 Functional restrictions during long time recording to DVD-RAM


Function Restrictions

Filing function Single Image Transfer to DVD-RAM is disabled.


And Simplified Transfer of the Toolbar is disabled.

Measurement function Saving the report to DVD-RAM is disabled.


And setup dialog box becomes unusable.

Exam. info. display area Images in DVD media become invisible.

Comparison window Comparison window closed in case of playing the image in


DVD media.

Disk operation Both of DVD Format and DVD Eject becomes unusable.

APPLICATION function APPLICATION Menu becomes unusable.

Three-dimensional display unit Saving Volume data to DVD-RAM is disabled.


(Real-Time) (option)

Table 4.1-3 Functional restrictions during long time recording to USB HDD
Function Restrictions

HDD Media operation Both of USB HDD Format and USB HDD Remove becomes
unusable.

4.2 Setting of start/stop recording


To start recording, press the USER pedal of the Foot switch (For freeze/user define) (option),
REC key in the case that setting for Long time recording is done.
For details about setting of REC key and Foot switch (Option), see the subsection REC
Key/Foot SW in the chapter Tab menus in the separate INSTRUCTION MANUAL HI VISION
Avius Operation.

24 Q1E-EZ1204
Chapter 4 - Long time recording mode

4.3 Setting of record condition


Please choose the "LongTime REC" of property page in Tab Menu→[Setup]→[Filing].
Setup Filing (LongTime REC) is displayed as Figure 4.3-1.
Please set the record condition as following. After setting, push the OK button to make the
change available. Push the Cancel button to make the change will not be available.

Figure 4.3-1 Menu of Setup Filing (LongTime REC)

The item of Long time recording is not displayed when the Digital Capture Card in
not connected or has a trouble. In this case, please call Service.

Q1E-EZ1204 25
Chapter 4 - Long time recording mode

■ Picture
The compression level at the time of recording can be chosen.
Please choose one from the Compression combo box.
y High-Quality Record video-clip with high quality.
Accordingly the file size is big.

y Standard Record video-clip with the balance of quality and size.

y High-Compression Record video-clip with small size.


If quality is the priority, please choose other level.

Compression Level Image Quality Recordable time to DVD-RAM

High-Quality High 1 hour

Standard ↑ 2 hours

High-Compression Low 4 hours

y Since the digital video archiving software compresses image data, there might be
a change in color in the display of fine lines.
y There may be degradation in the image quality of the first part and scene change
part of clips recorded with the long time recording mode. However, this is a
feature of MPEG-2 compression (compression using the images from the
previous and following frames), and is not a software failure.

■ Destination
Either of the following items is selectable as destination.
Please choose one from the combo box.
ƒ Hard Disk
ƒ DVD-RAM
ƒ USB HDD

y It is not possible to record in DVD media other than DVD-RAM such as


DVD-R.
y Destination of Long time recording can not be set even if the setting of
[Common] →[Destination] → [Use the data destination as a common setting]
is ON. According to the above-mentioned, Select Hard Disk, DVD-RAM or
USB HDD.

26 Q1E-EZ1204
Chapter 4 - Long time recording mode

■ Auto Chapter
Timing in which chapter is set automatically can be specified.
Please check the box of the item that wants to set chapter automatically.

You can set up a maximum of 500 chapters.


If you try to go beyond the limit of 500, a message will appear indicating that you
cannot set any more chapters.

Q1E-EZ1204 27
Chapter 4 - Long time recording mode

4.4 Setting of the record condition temporarily


The record condition can be changed temporarily from the Tab Menu→[Tool]→[Filing].
The changed setting of record condition is held until the following operations are performed.
z Turn off the power of equipment
z Set again in the Tab Menu→[Setup]→Filling
z Change the application
Please refer to "4.3 Setting of record condition" about the "Image Filing".
The setting is applied in recording after OK is pressed.
Moreover, unlike "4.3 Setting of record condition", on this screen, recording is performed by
condition of preset when clicking OK.
Please refer to "4.3 Setting of record condition" about configuration of the items.

Figure 4.4-1 Filing (LongTime REC) screen

The item of Long time recording is not displayed when the Digital Capture Card in
not connected or has a trouble. In this case, please call Service.

28 Q1E-EZ1204
Chapter 4 - Long time recording mode

4.5 Record
(1) Starting record
Press the USER pedal of the Foot switch (For freeze/user define) (Option), REC key in
the case that setting for Long time recording is done, the ultrasound images then will be
recorded.
When the record starts, the elapsed time will be displayed in cine bar area.
During recording, it is displayed “Longtime REC” on progress bar in System information
display area.
See "3.5.1 Real-time" for Cine memory playback bar and System information display
area.

y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y When the pointer is displayed while image is capturing, the pointer is recorded in
the image.
y The item of Long time recording is not displayed when the Digital Capture Card
in not connected or has a trouble. In this case, please call Service.
y When destination of Long time recording is set the hard disk, it is not possible to
record video-clip if there is the task of accessing DVD-RAM in the Transfer
spool list. For details about the Transfer spool, please refer to the subsection
Transfer Spool in the chapter Filing Function in the separate INSTRUCTION
MANUAL HI VISION Avius Operation.

(2) Stopping record

Recording will stop as below case.


ƒ When press the USER pedal of the Foot switch (For freeze/user define) (Option),
REC key in the case that setting for Long time recording is done.
End
ƒ When press the End Exam key Exam .
ƒ When launch the screensaver.
During recording end processing, it is displayed “Terminating” on progress bar in System
information display area. An elapsed time becomes reversing display . When the
clip is recorded into DVD-RAM, it needs about 10 seconds for finishing work.
When recording is completely finished, the elapsed time disappear.

Q1E-EZ1204 29
Chapter 4 - Long time recording mode

y If you capture a Single Image while long time recording is executing, “Longtime
REC” is displayed on the progress bar in system information display area instead
of “Recording”, though it is possible to capture a Single Image properly.
y The exam. info. display area and filing dialog box display the thumbnails for
captured images in new order of capture end time.
y When it takes recording end processing at the time of recording to DVD-RAM
more than 10 seconds, it is thought that fragmentation of the DVD-RAM media
gets worse. Please format DVD-RAM media whether you change DVD-RAM
media for a new one. Because all the data are erased when you format
DVD-RAM, please back up data by all means when you record necessary data.

4.6 Playback
Recorded video-clip can be played back using the following procedure, in the same way as is
normally done for single and multi images.

1 When Freeze is switched on, press the READ key READ


to open the
filing screen.
For details, see the chapter Filing Function in the separate INSTRUCTION MANUAL HI
VISION Avius Operation. And see "3.6 Playback" for filing display.

2 Select the video-clip data ( mark display) from the thumbnails.


3 Press the Retrieve button.

30 Q1E-EZ1204
Chapter 4 - Long time recording mode

y You can use the SOUND VOL toggle on the keyboard panel to
adjust the Doppler sound volume during playback.
y When you change the image conditions such as display depth during recording,
if you take a measurement on review image for frames within 3 seconds before
and after that point, the Mode Adjust appears.
Set the same image conditions for both the displayed image and the Mode Adjust
before taking measurements.
y Following measurement items are not compatible with measurements of review
image for video-clips.
Str. Ratio(Option), Str. Histo.(Option), D-Profile, Vascularity, Histogram,
CFM-Velo., MVG-M, %WT(Option), Color Tissue Tracking(Option), LA
Tracking(Option), IMT(Option), TIC(Option)
y Following measurement item has the functional restrictions with measurements
of review image for video-clips.
- It is impossible to perform Real time Doppler measurement.
- The PISA measurement in MV Regurg and TV Regurg measurement is
impossible to calculate.
y There may be degradation in the image quality of the first part and scene change
part of clips recorded with the long time recording mode. However, this is a
feature of MPEG-2 compression (compression using the images from the
previous and following frames), and is not a software failure.
y If the digital video archiving software has not been installed, you cannot play
back video-clips.
If you specify a video-clip and press the Play button, a message appears
indicating that playback of the clip is not possible.
y Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or
manipulate the record files. And the clips captured by other model Ultrasound
Diagnostic Scanner (For example EUB Series, HI VISION 900) cannot be
played back and operated on HI VISION Avius.
y Video-clips does not support DICOM format.
y The screen might flicker when the dialog box such as the menu of setup filing
dialog box is displayed while the video-clip is reviewing. In this case, please
wait for 10 seconds or press the [Alt] key on alphanumeric keyboard (option).
y On rare occasions, the drawing of retrieved images might not be updated when
playing MPEG-2 clips in the Review window or Comparison window. If this
occurs, close the Review window or Comparison window and try to play the
MPEG-2 clip again.

Q1E-EZ1204 31
Chapter 4 - Long time recording mode

4.6.1 Video-clip information ···············································································


When using single image display for a video-clip, the following video-clip information will
appear on the bottom right of the window.


Chapter 001 / 002 0:00:00 / 0:01:53 ①Current chapter ②Total chapter
③Currect time ④Total time

Figure 4.6-1 Video-clip information

4.6.2 Screen buttons of single image playback ·················································


When using single image display for a video-clip, the screen buttons at the bottom of the
window change to the screen buttons for single image playback. If the File Operations button
File Operations is pressed, the screen buttons change to the screen buttons for file operation and file
operation becomes possible. At this time, the buttons shaded in gray in Figure 4.6-3 cannot be
used.
# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End

#
Measurement Slideshow ■ Prev Page Next Page Sound Volume Chap List

Figure 4.6-2 Screen Buttons of Single Image Playback

# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End

#
Delete Trim ■ Prev Page Next Page Sound Volume Chap List

Figure 4.6-3 Screen Buttons of File Operation

TIC : It is possible to use this when clip single image playback


is displayed.

File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).

Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.

Trim : It is possible to use this when clip single image playback


is displayed.

32 Q1E-EZ1204
Chapter 4 - Long time recording mode

Chap Jump : Used to jump to a chapter by turning the screen link


encoder. Turn the encoder to the left to jump to a previous
chapter, and to the right to jump to a later chapter.

Speed : Used to change the playback speed by turning the screen


link encoder. Turn the encoder completely to the left for
-32x speed, and then increase the speed in the following
steps with each turn to the right: -8x, -2x, -1x, -1/2x,
-1/4x, -1/8x, 0x, 1/8x, 1/4x, 1/2x, 1x, 2x, 8x, 32x.

Filing : Returns to the filing screen.

To Multi : Switches to multi image display when playing back


multiple images.

Select Start : It is possible to use this when clip single image playback
is displayed.

Select End : It is possible to use this when clip single image playback
is displayed.

Measurement : Switches to screen buttons for measurement. For details,


see the separate INSTUCTION MANUAL HI VISION
Avius Measurement.

Slide Show : Automatically moves from the currently displayed image


to display the next image. It is possible to use this when
multiple images are played and single image playback is
displayed.

■ (Stop) : Stops playback, fast-forward, and rewind.



▼ (Play) : Plays the clip at normal speed.

Previous Page : Switches the window to the previous page.

Next Page : Switches the window to the next page.

Sound Volume : Used to adjust the volume of a video-clip by turning the


screen link encoder.

Chap List : Displays a list of scenes that have chapters set.

You can play back the Doppler sound only when playing back the clip at normal
speed.

Q1E-EZ1204 33
Chapter 4 - Long time recording mode

4.6.3 Screen buttons of multi image playback ···················································


When using multi image display for a video-clip, the screen buttons at the bottom of the
window change to the screen buttons for video-clip multi-image playback. The same as for
single image playback, if the File Operations button File Operations is pressed, the screen buttons
change to the screen buttons for file operation and file operation becomes possible.

#
File Operations Speed Filing To Single

# #
Measurement Images ■ Prev Page Next Page Sound Volume Chap List

Figure 4.6-4 Screen Buttons of Multi Image Playback for Video-clip

File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).

Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.

Trim : It is possible to use this when clip single image playback


is displayed.

Speed : It is possible to use this when video-clip single image


playback or clip playback is displayed.

Filing : Returns to the filing screen.

To Single : Switches the window display to single image display.

Measurement : It is possible to use this when single image playback is


displayed.

Images : Used to change the number of images displayed on screen


by turning the screen link encoder. The number of images
displayed can be either 4, 9, or 16.

■ (Stop) : It is possible to use this when video-clip single image


playback or clip playback is displayed.
▼ (Play) : It is possible to use this when video-clip single image
playback or clip playback is displayed.

Prev Page : Switches the window to the previous page.

Next Page : Switches the window to the next page.

Sound Volume : It is possible to use this when video-clip single image


playback is displayed.

34 Q1E-EZ1204
Chapter 4 - Long time recording mode

Chap List : Displays a chapter list.

4.7 Playback with Comparison window


It is possible play Longtime Rec video-clip on Comparison window; For details, see the section
Comparison window in the chapter Configuration of the Examination Window in the separate
INSTRUCTION MANUAL HI VISION Avius Operation.

4.8 Video-clips with Recording Errors


Video-clips that experience a recording error during recording are saved as video-clips with
recording errors, and displayed along with the mark in the filing dialog box.
The following restrictions apply to video-clips with recording errors:
z Mode adjustments are required when taking a measurement on review image.
z You might not be able to use chapters to move to the start of a scene.
Recording errors will occur in video-clips under the following circumstances:
z When the scanner stops abnormally during recording
z When you turn off a breaker switch during recording
z When you remove a USB HDD during recording to it

Q1E-EZ1204 35
Chapter 4 - Long time recording mode

36 Q1E-EZ1204
Chapter 5 - Specifications

Chapter 5 - Specifications
5.1 Clip capture mode
5.1.1 Common···································································································
Preset 8 types

Compression level Standard, High-Compression

Image format AVI (uncompressed), AVI (Motion JPEG Compression),


DICOM, DICOM JPEG (Lossy)

Playback speed

Play 1×

Rewind -1×

Slow-forward 1/8×, 1/4×, 1/2×

Slow-rewind -1/8×, -1/4×, -1/2×

y Biomedical waveform display unit is required for R trigger capture, and R-R
capture.
y To select DICOM or DICOM JPEG (lossy) for the image format, the optional
DICOM Software (Transfer and Media Storage) is required.

5.1.2 Real-time ··································································································


Destination Hard Disk, DVD-RAM, USB Memory, USB HDD,
Network Folder

Transfer mode Free, R trigger

Capture rate

Free 6, 8, 10, 15, 20, 30 Fr/s 6 steps

R trigger 30Fr/s

Q1E-EZ1204 37
Chapter 5 - Specifications

Capture time

Free

AVI (Motion JPEG Compression) or DICOM JPEG (Lossy)

10 s(30 Fr/s), 90 s(20 Fr/s), 120 s(15 Fr/s),


180 s(10 Fr/s), 225 s(8 Fr/s), 300 s(6 Fr/s)

AVI (uncompressed) or DICOM

10 s(30 Fr/s), 18 s(20 Fr/s), 24 s(15 Fr/s),


36 s(10 Fr/s), 45 s(8 Fr/s), 60 s(6 Fr/s)

R trigger 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 beat

5.1.3 Freeze on ·································································································


Destination Hard Disk, DVD-RAM, USB Memory, USB HDD,
Network Folder

Transfer mode Frame to Frame (F-F), R-Wave to R-Wave (R-R), All

Capture time

Frame to Frame ALL, 10, 20, 30, 40, 50, 60,


70, 80, 90, 100 frame, Manual

R-Wave to R-Wave ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 beat, Manual

38 Q1E-EZ1204
Chapter 5 - Specifications

5.2 Long time recording mode


Image format MPEG-2
(can be played on filing function)

Destination DVD-RAM, Hard Disk, USB HDD

Continuous recordable time Maximum 1 examination

Recordable time to DVD

High-Quality Approx. 1 hour (8Mbps)

Standard Approx. 2 hour (4Mbps)

High-Compression Approx. 4 hour (2Mbps)

Recording area Basic area

Record and play Doppler sound Applicable

Playback speed

Play 1×

Fast-forward 2×, 8×, 32×

Fast-rewind -1×, -2×, -8×, -32×

Slow-forward 1/8×, 1/4×, 1/2×

Slow-rewind -1/8×, -1/4×, -1/2×

Playback to the start by chapter Applicable

y Clip capture mode and Long time recording mode cannot be used at the same
time.
y Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or
manipulate the record files. And the clips captured by other model Ultrasound
Diagnostic Scanner (For example EUB Series, HI VISION 900) cannot be
played back and operated on HI VISION Avius.

Q1E-EZ1204 39
Chapter 5 - Specifications

40 Q1E-EZ1204
Appendix A - Playback Clips with PC

Appendix A - Playback Clips with PC


The captured clip files by Digital Video Archiving Software can be copied to CD or DVD and
play back with PC.

A.1 Playback with Windows


A.1.1 Motion JPEG AVI clip by Clip Capture Mode ···········································
(1) Playback with Windows
It is possible to play back the clip of Motion JPEG with Windows.
We have made sure of action with the following version of OS:
OS Edition Condition of Motion JPEG
Replaying

Windows 8.1 Pro

Windows 8.1

Windows 8 Pro

Windows 8

Ultimate

Professional
Windows 7 Home Premium
Motion JPEG can be played
Home Basic back without installing any
Starter CODEC.

Ultimate

Home Premium
Windows Vista
Business

Home Basic

Professional
Windows XP
Home Edition

Q1E-EZ1204 41
Appendix A - Playback Clips with PC

(2) Playback with PowerPoint for Windows


It is possible to play back he clip of Motion JPEG with PowerPoint by inserting it into the
slide. We have made sure of action with the following version.
Version of PowerPoint Condition of Motion JPEG Replaying

PowerPoint 2013

PowerPoint 2010 Motion JPEG can be played back with

PowerPoint 2007 inserting its file in the slide.

PowerPoint 2003
It is possible to insert the clip of Motion JPEG into the slide of PowerPoint by below step.
ƒ PowerPoint 2003
1. On the [Insert] menu, point to [Movies and Sounds], and then click [Movie
from File].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.
ƒ PowerPoint 2007, 2010
1. On the [Insert] tab, in the [Media Clips] group, click the arrow under [Movie],
and then click [Movie from File].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.
ƒ PowerPoint 2013
1. On the [Insert] tab, in the [Media] group, click the arrow under [Video], and
then click [Video on My PC].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.

42 Q1E-EZ1204
Appendix A - Playback Clips with PC

A.1.2 MPEG-2 clip by Long Time Recording Mode ···········································


(1) Playback with Windows
It is possible to play back the clip of MPEG-2 with Windows.
We have made sure of action with the following version of OS:
OS Edition Condition of MPEG-2
Replaying

Ultimate
Windows 7 Professional It is possible to play back the
Home Premium MPEG-2 clip by using
Windows Media Player.
Ultimate
Windows Vista
Home Premium

The following table shows the confirmed combination of OS and DVD player software.
OS Edition DVD player software

Windows 8.1 Pro

Windows 8.1
Power DVD13
Windows 8 Pro

Windows 8

Home Basic
Windows 7
Starter

Business Power DVD10


Windows Vista
Home Basic Power DVD7

Professional
Windows XP
Home Edition

Q1E-EZ1204 43
Appendix A - Playback Clips with PC

y When you do playback the MPEG-2 video clip, the image quality (Sharpness /
Color Tone) and the aspect ratio depend on DVD player software and the
graphics board of the PC.
We recommend that you obtain evaluation copy of the DVD player software and
confirm the following contents before introduction.
■ Please do playback the MPEG-2 video clip with the DVD player software
and check the image quality (Sharpness / Color Tone) and aspect ratio do
not have any problem.
■ If you do playback the MPEG-2 video clip with Windows Media Player or
PowerPoint, please do playback the MPEG-2 video clip with the Windows
Media Player and check the image quality (Sharpness / Color Tone) and
aspect ratio do not have any problem.
y If you need the detailed information of the DVD player software used for
MPEG-2 playback, please ask to developer of each DVD player software and
PC.

(2) Playback with PowerPoint for Windows


To paste and playback MPEG-2 with PowerPoint, it is required that Windows (Media
Player) can playback MPEG-2.
We have made sure of action with the following version.
Version of PowerPoint Condition of MPEG-2 Replaying

PowerPoint 2013
It is possible to play back the MPEG-2 clip
PowerPoint 2010
by inserting Windows Media Player into
PowerPoint 2007 slide.
PowerPoint 2003
MPEG-2 can paste into PowerPoint by below steps with the environment that Windows
Media Player can playback.
ƒ PowerPoint 2003
1. Select [Object] from [Insert] menu.
2. Insert item list is shown with appeared the object insertion dialog box, then
select [Windows Media Player] and push OK button
3. Windows Media Player is inserted into slide, then right-click on the Windows
Media Player and select [Property] in menu.
4. Property dialog box appears, and then select (property page) item and push …
button that displayed right of item.
5. Property dialog box of Windows Media Player appears, then enter file name to
playback into [File or URL] item and push OK button to close Property dialog
box.

44 Q1E-EZ1204
Appendix A - Playback Clips with PC

ƒ PowerPoint 2007, 2010, 2013


1. On the [Developer] tab#, in the [Control] group, select the [More Controls].
2. Select [Windows Media Player] from the list.
3. Drag the pointer to decide area where Windows Media player is inserted.
4. Windows Media Player is inserted into slide, then right-click on the Windows
Media Player and select [Property] in menu.
5. Property dialog box appears, and then select (property page) item and push …
button that displayed right of item.
6. Property dialog box of Windows Media Player appears, then enter file name to
playback into [File or URL] item and push OK button to close Property dialog
box.

# If the [Developer] tab is not shown, show it by below step.


y PowerPoint 2007
1. Click the Microsoft Office button in the top left corner of the screen to open
the drop down menu.
2. Click on the PowerPoint Options button located at the bottom of the drop
down box to bring up the [PowerPoint Options] dialog box.
3. Click [Popular], and then select the [Show Developer tab in the Ribbon]
check box.
y PowerPoint 2010, 2013
1. Click the [File] tab and click [Option].
2. Click [Customize Ribbon].
3. In the [Customize the Ribbon] window, under [Customize the Ribbon], select
the [Developer] check box.

Q1E-EZ1204 45
Appendix A - Playback Clips with PC

46 Q1E-EZ1204
Appendix B - Compress Rate of Clips

Appendix B - Compress Rate of Clips


B.1 Compress rate and formula of file size
The standard of compress rate and formula of estimated file size are shown below.
The value shown here is a standard to the last. The actual compression rate depends on the file.
Mode Setting Compress Rate Formula of Estimated file
[%] size [MB]

Clip capture Standard Compress to about 3% Capture frame


mode High-Compression Compress to about 2% ×2.25MB×Compress Rate

Mode Setting bit rate[Mbps] Formula of Estimated file


size [MB]

Long Time High-Quality 8 Number of seconds to record


Recording Standard 4 × bit rate[Mbps]÷
Mode 8[bits/byte]
High-Compression 2

B.2 Example of calculation


When you record by setting of high compression during 10 seconds, you can calculate the file
size by the following formulas.

(1) Clip Capture Mode


10[s]×30[Fr/s]×2.25[MB]×2[%]=13.5[MB]

(2) Long Time Recording Mode


When a clips is recorded for 10s in High-Compression.
10[s]×2[Mbps]÷8[bits/byte]=2.5[MB]

Q1E-EZ1204 47
Appendix B - Compress Rate of Clips

48 Q1E-EZ1204
INDEX

INDEX
Outline of Long time recording mode ........................23

Auto Chapter.............................................................. 27

Playback ...............................................................18, 30
C Playback Clips with PC..............................................41
Cautions ....................................................................... 1 Playback with Comparison window...........................35
Clip capture mode .................................................... 3, 7 Playback with Windows .............................................41
Purpose of use ..............................................................1


Features........................................................................ 3
F-Fout......................................................................... 10 R trigger .......................................................................9
Free .............................................................................. 8 Record ........................................................................29
Functional restrictions during long time recording .... 23 R-Rout ........................................................................10
Functional restrictions during long time recording to
DVD-RAM ............................................................ 24

Functional restrictions during long time recording to Screen buttons of multi image playback ....................34
USB HDD .............................................................. 24 Screen buttons of single image playback ...................32
Setting of capture condition .........................................7
I Setting of record condition .........................................25
Installation.................................................................... 5 Setting of start/stop recording ....................................24
Setting of the capture condition temporarily ..............14
L Setting of the record condition temporarily................28
Long time recording mode ................................. 2, 3, 23 Specifications .............................................................37
Standard Components...................................................5


Optional components ................................................... 5
Outline ......................................................................... 1 Video-clip information ...............................................32
Outline of Clip capture mode....................................... 7 Video-clips with Recording Errors.............................35

Q1E-EZ1204 49

Вам также может понравиться