EZU-DV4
INSTRUCTION MANUAL
★ Before using this system, be sure to thoroughly read this manual and make yourself
familiar with this system.
★ After reading this manual, keep it in an easily accessible place close to the system.
Tokyo, Japan
Q1E-EZ1204-9
This symbol indicates a potential (latent) danger that could result in death or
serious injury of personnel, total destruction of equipment, or fire if the warning
is ignored and the equipment is handled incorrectly. The following is an
example of a potential danger:
(Ex.) Failure to observe this warning could result in death if the cover is opened
and a high-voltage terminal is touched.
This symbol indicates possible danger that could result in light or moderate
injury of personnel, partial equipment damage, or deletion of computer data if
the warning is ignored and the equipment is handled incorrectly.
Cautions on exportation:
When exporting this equipment, be sure to check the Foreign Exchange and Foreign
Trade Control Law and the regulations related to export control in the United States of
America, and perform the necessary procedures.
Contact Hitachi or an authorized representative if you have further inquiries.
Revision history:
First edition: November 2009
Eighth edition: April 2013
Ninth edition: April 2014
Introduction
Thank you for purchasing the “Digital Video Archiving Software ”.
To use this software safely and correctly, it is essential to have a full understanding of its
functions, operation. Read this instruction manual thoroughly before using this software.
To use this software, Digital capture card unit is required.
Q1E-EZ1204 i
ii Q1E-EZ1204
Contents
Introduction................................................................................................................................................i
Chapter 1 - Outline.............................................................. 1
1.1 Purpose of use ...................................................................................................................................1
Q1E-EZ1204 iii
3.4.1 Setup Filing screen............................................................................................................................ 14
3.5 Capture............................................................................................................................................ 15
3.5.1 Real-time........................................................................................................................................... 15
3.5.2 Freeze................................................................................................................................................ 17
Chapter 5 - Specifications..................................................37
5.1 Clip capture mode ........................................................................................................................... 37
5.1.2 Real-time........................................................................................................................................... 37
iv Q1E-EZ1204
Appendix A - Playback Clips with PC................................ 41
A.1 Playback with Windows ...................................................................................................................41
INDEX ............................................................................... 49
Q1E-EZ1204 v
vi Q1E-EZ1204
Chapter 1 - Outline
Chapter 1 - Outline
1.1 Purpose of use
This Digital Video Archiving Software captures real-time clips displayed on ultrasound
diagnostic scanner.
1.2 Cautions
1.2.1 General·····································································································
z Hitachi bears no responsibility for data loss due to unexpected accidents, malfunction, or
incorrect operation. Be sure to make backups of important data.
z When capturing important data, be sure to perform a test capture in advance to confirm
that capturing works correctly.
z Clips that are compressed and captured with the digital video archiving software will
show degradation in image quality. Use this software only to the extent that degradation
will not affect diagnoses.
z Do not turn off the breaker switches while capturing clips.
Turning off the breaker switches while capturing clips might result in damage to drives,
disks, and the content of disks.
While capturing clips, the scanner will not shut down even if you press the
ON/STANDBY key .
To shut down the scanner, first make sure that the capturing of clips is complete, and
then set the ON/STANDBY key to OFF.
z Any changes made to DGA or BSA while playing back clips will not change the DGA or
BSA that appear in the recorded scene.
When taking measurements that are affected by values such as DGA and BSA, check the
values that are displayed in the dialog box for entering patient menu or the Measurement
Report, as necessary.
z The scene where image popup and a dialog box were displayed on ultrasound image is
recorded, but please do not measure it in what become the false measurement.
z Make sure that the drive access lamp is off before performing the following operations.
Performing the following operations while the access lamp is on or flashing might result
in damage to drives, disks, and the content of disks.
Pressing the ON/STANDBY key
Pressing the EJECT key EJECT
Q1E-EZ1204 1
Chapter 1 - Outline
Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or manipulate the
record files. And the clips captured by other model Ultrasound Diagnostic Scanner
(For example EUB Series, HI VISION 900) cannot be played back and operated on
HI VISION Avius.
y For details about DVD-RAM Media, see the chapter Recommended media/Drive
and Handling of a DVD-RAM/DVD-R Media in the separate INSTRUCTION
MANUAL HI VISION Avius Preparation.
y Recording errors are more likely to occur if you partition the capture region on
DVD-RAM media. Therefore, do not use DVD-RAM media that you have
repeatedly used to save and delete images for recording.
However, if you do use DVD-RAM media that you have repeatedly used to save
and delete images, be sure to first delete all images from the DVD-RAM media
before performing recording in long time recording mode.
2 Q1E-EZ1204
Chapter 1 - Outline
1.3 Features
This digital video archiving software captures real-time clips as high quality digital images.
Both the clip capture mode and long time recording mode are available for capturing.
1.3.1 Clip capture mode ····················································································
z You can record videos in uncompressed format or Motion JPEG Format.
z You can capture every heartbeat, with the use of an optional biomedical waveform
display unit.
z You can set 8 types of capture conditions, and also set in advance the conditions to be
used for each diagnostic region.
z You can perform high-speed capturing of continuous frame images in cine memory when
freeze occurs.
z Clips are compatible with AVI and DICOM formats.
z You can perform clip analyses, such as measurements and tracking, on captured clips.
1.3.2 Long time recording mode········································································
z You can record videos of examinations in MPEG-2 format.
z You can record direct to DVD-RAM media or USB HDD.
z You can transfer single images while recording.
z You can record and play back the captured Doppler sound along with diagnostic images.
z You can take measurements on recorded clips.
z You can specify settings for adding chapters according to the scenes that you are
recording.
y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y In this instruction manual, “clip” means the multi image that captured by clip
capture mode, and “video-clip” means the multi image that captured by long
time recording mode.
Q1E-EZ1204 3
Chapter 1 - Outline
4 Q1E-EZ1204
Chapter 2 - Software Components and Installation
The MPEG-2 decoder software recorded on MPEG-2 Decoder Installation CD can not
be installed in PC.
2.2 Installation
This software is installed and used in the equipment.
This software is installed at the time of shipment from manufacturer.
Or, it maybe installed to your equipment which has been using, by the server of our corporation
or appointed by our corporation.
Except the servers who have been educated by our corporation, please DO NOT
disassemble or rebuild the equipment.
Q1E-EZ1204 5
Chapter 2 - Software Components and Installation
6 Q1E-EZ1204
Chapter 3 - Clip capture mode
(2) Capture clip from cine memory can be executed with freeze on.
(3) Capture clip is executed with the capture condition that has been set beforehand.
It is not possible to select some capture conditions when the Digital Capture Card is
not connected or has a trouble. In this case, please call Service.
Q1E-EZ1204 7
Chapter 3 - Clip capture mode
■ Mode
Transfer Mode at the time of real time can be chosen.
(1) Free
Capture until the set time (second(s)) elapses.
Please set the record time in "Capture Time".
And, please select the Capture Rate from the combo box.
Capture Rate can be chosen from the following values.
30, 20, 15, 10, 8, 6 Fr/s
When the capture starts, it will end automatically after the time which has been set
elapses and produce the captured clip.
8 Q1E-EZ1204
Chapter 3 - Clip capture mode
(2) R trigger
The frame during the chosen R-wave trigger is captured as one file.
Please set the heartbeat in "Number".
For one file, 10 heartbeats(beat) is the maximum that in which it can be captured.
The time of capture is calculated automatically with the heart rate when capture starts
and the heartbeat which has been set.
After the capture starts, capture finishes automatically when the
automatically-calculated-time elapses, and then the captured clip is archived.
From this clip, images are taken out and the amount is decided to the heartbeat which
has been set.
Q1E-EZ1204 9
Chapter 3 - Clip capture mode
■ Mode
Transfer Mode at the time of freeze can be chosen.
(1) F-Fout
This is to record a series of continued frames selected in discretion as one file. The
number of frames chosen when “Auto” was chosen by the Range is recorded.
ALL, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100
You can select the starting frame and ending frame for producing Multi Images when
“Manual” was chosen by the Range. After REC key and User pedal of Foot
SW(Option) assigned Record Multi Image is pressed, Multi Images are produced
following to messages.
(2) R-Rout
This is to record a series of frames in R-wave time phase selected in discretion as one
file. The number of heartbeats chosen when “Auto” was chosen by the Range is
recorded.
ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
You can select the starting R-wave frame and ending R-wave frame for producing
Multi Images when “Manual” was chosen by the Range. After Rec key and User
pedal of Foot SW(Option) assigned Record Multi Image is pressed, Multi Images are
produced following to message.
(3) ALL
This is to record all the cine image as one file.
Range and Number are not displayed.
10 Q1E-EZ1204
Chapter 3 - Clip capture mode
3.2.4 Common···································································································
■ Compression
The compression level at the time of capturing in AVIm [Motion JPEG compression] can
be chosen.
Please choose one from the Compression combo box.
y Standard Capture clip with the balance of quality and size.
y For analysis, use clips that were captured both by using AVI [uncompressed] and
after freezing the image.
Using clips captured by using AVIm [Motion JPEG compression] or clips
captured in real time might result in reduced analytical precision.
y Since the digital video archiving software compresses image data, there might be
a change in color in the display of fine lines.
Q1E-EZ1204 11
Chapter 3 - Clip capture mode
3.2.5 General·····································································································
■ Destination in Freeze
On the Setup Filing screen, select Record Multi Image and then General. Only the drives
that can be selected as a save destination for clips at the time of freeze are displayed in
the menu. Select the check box for the drive you want to select as the save destination.
y For details, see the subsection Recording Multi Image in the chapter Filing
Function in the separate INSTRUCTION MANUAL HI VISION Avius Operation.
y The setting of [Recording] → [General] → [Freeze] can not be used when the
setting of [Common] → [Destination] → [Use the data destination as a
common setting] is ON.
12 Q1E-EZ1204
Chapter 3 - Clip capture mode
Q1E-EZ1204 13
Chapter 3 - Clip capture mode
It is not possible to select some capture conditions when the Digital Capture Card is
not connected or has a trouble. In this case, please call Service.
14 Q1E-EZ1204
Chapter 3 - Clip capture mode
3.5 Capture
3.5.1 Real-time ··································································································
(1) Starting capture
Press the Rec key and User pedal of Foot SW(Option) that assigned Recording Multi
Image at the time of real time, the ultrasound images then will be captured with real-time.
When the capture starts, the elapsed time and record time will be displayed bottom left of
cine bar.
During capturing, “Recording” is displayed on progress bar in System information
display area.
Cine memory
playback bar
System information
display area
Figure 3.5-1 Cine memory playback bar, System information display area
Progress bar
Q1E-EZ1204 15
Chapter 3 - Clip capture mode
y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y The next record operation (clip and image) and the Filing operation cannot be
performed during transferring the captured clip.
y When the pointer is displayed while image is capturing, the pointer is recorded in
the image.
# In this case, playback image motion may be slower than at the time of a record.
16 Q1E-EZ1204
Chapter 3 - Clip capture mode
Clip capture mode and Long time recording mode cannot be used at the same time.
When you are recording one mode and start the other recording mode, it is necessary
to stop recording.
Q1E-EZ1204 17
Chapter 3 - Clip capture mode
3.6 Playback
Captured clip can be played back using the following procedure, in the same way as is normally
done for single and multi images.
Thumbnail
18 Q1E-EZ1204
Chapter 3 - Clip capture mode
②
①
①Current frame ②Total frame
No. 1 / 100 0:00:00 / 0:01:53
③Current time ④Total time
③
④
# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End
Q1E-EZ1204 19
Chapter 3 - Clip capture mode
File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).
Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.
20 Q1E-EZ1204
Chapter 3 - Clip capture mode
▼
▼ (Play) : Plays the clip at normal speed.
#
File Operations Speed Filing To Single
#
Measurement Images ■ Prev Page Next Page Division Chap List
File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).
Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.
Q1E-EZ1204 21
Chapter 3 - Clip capture mode
22 Q1E-EZ1204
Chapter 4 - Long time recording mode
Filing function Both of the filing dialog box and the setup dialog box becomes
unusable.
Q1E-EZ1204 23
Chapter 4 - Long time recording mode
Disk operation Both of DVD Format and DVD Eject becomes unusable.
Table 4.1-3 Functional restrictions during long time recording to USB HDD
Function Restrictions
HDD Media operation Both of USB HDD Format and USB HDD Remove becomes
unusable.
24 Q1E-EZ1204
Chapter 4 - Long time recording mode
The item of Long time recording is not displayed when the Digital Capture Card in
not connected or has a trouble. In this case, please call Service.
Q1E-EZ1204 25
Chapter 4 - Long time recording mode
■ Picture
The compression level at the time of recording can be chosen.
Please choose one from the Compression combo box.
y High-Quality Record video-clip with high quality.
Accordingly the file size is big.
Standard ↑ 2 hours
y Since the digital video archiving software compresses image data, there might be
a change in color in the display of fine lines.
y There may be degradation in the image quality of the first part and scene change
part of clips recorded with the long time recording mode. However, this is a
feature of MPEG-2 compression (compression using the images from the
previous and following frames), and is not a software failure.
■ Destination
Either of the following items is selectable as destination.
Please choose one from the combo box.
Hard Disk
DVD-RAM
USB HDD
26 Q1E-EZ1204
Chapter 4 - Long time recording mode
■ Auto Chapter
Timing in which chapter is set automatically can be specified.
Please check the box of the item that wants to set chapter automatically.
Q1E-EZ1204 27
Chapter 4 - Long time recording mode
The item of Long time recording is not displayed when the Digital Capture Card in
not connected or has a trouble. In this case, please call Service.
28 Q1E-EZ1204
Chapter 4 - Long time recording mode
4.5 Record
(1) Starting record
Press the USER pedal of the Foot switch (For freeze/user define) (Option), REC key in
the case that setting for Long time recording is done, the ultrasound images then will be
recorded.
When the record starts, the elapsed time will be displayed in cine bar area.
During recording, it is displayed “Longtime REC” on progress bar in System information
display area.
See "3.5.1 Real-time" for Cine memory playback bar and System information display
area.
y Clip capture mode and Long time recording mode cannot be used at the same
time.
When you are recording one mode and start the other recording mode, it is
necessary to stop recording.
y When the pointer is displayed while image is capturing, the pointer is recorded in
the image.
y The item of Long time recording is not displayed when the Digital Capture Card
in not connected or has a trouble. In this case, please call Service.
y When destination of Long time recording is set the hard disk, it is not possible to
record video-clip if there is the task of accessing DVD-RAM in the Transfer
spool list. For details about the Transfer spool, please refer to the subsection
Transfer Spool in the chapter Filing Function in the separate INSTRUCTION
MANUAL HI VISION Avius Operation.
Q1E-EZ1204 29
Chapter 4 - Long time recording mode
y If you capture a Single Image while long time recording is executing, “Longtime
REC” is displayed on the progress bar in system information display area instead
of “Recording”, though it is possible to capture a Single Image properly.
y The exam. info. display area and filing dialog box display the thumbnails for
captured images in new order of capture end time.
y When it takes recording end processing at the time of recording to DVD-RAM
more than 10 seconds, it is thought that fragmentation of the DVD-RAM media
gets worse. Please format DVD-RAM media whether you change DVD-RAM
media for a new one. Because all the data are erased when you format
DVD-RAM, please back up data by all means when you record necessary data.
4.6 Playback
Recorded video-clip can be played back using the following procedure, in the same way as is
normally done for single and multi images.
30 Q1E-EZ1204
Chapter 4 - Long time recording mode
y You can use the SOUND VOL toggle on the keyboard panel to
adjust the Doppler sound volume during playback.
y When you change the image conditions such as display depth during recording,
if you take a measurement on review image for frames within 3 seconds before
and after that point, the Mode Adjust appears.
Set the same image conditions for both the displayed image and the Mode Adjust
before taking measurements.
y Following measurement items are not compatible with measurements of review
image for video-clips.
Str. Ratio(Option), Str. Histo.(Option), D-Profile, Vascularity, Histogram,
CFM-Velo., MVG-M, %WT(Option), Color Tissue Tracking(Option), LA
Tracking(Option), IMT(Option), TIC(Option)
y Following measurement item has the functional restrictions with measurements
of review image for video-clips.
- It is impossible to perform Real time Doppler measurement.
- The PISA measurement in MV Regurg and TV Regurg measurement is
impossible to calculate.
y There may be degradation in the image quality of the first part and scene change
part of clips recorded with the long time recording mode. However, this is a
feature of MPEG-2 compression (compression using the images from the
previous and following frames), and is not a software failure.
y If the digital video archiving software has not been installed, you cannot play
back video-clips.
If you specify a video-clip and press the Play button, a message appears
indicating that playback of the clip is not possible.
y Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or
manipulate the record files. And the clips captured by other model Ultrasound
Diagnostic Scanner (For example EUB Series, HI VISION 900) cannot be
played back and operated on HI VISION Avius.
y Video-clips does not support DICOM format.
y The screen might flicker when the dialog box such as the menu of setup filing
dialog box is displayed while the video-clip is reviewing. In this case, please
wait for 10 seconds or press the [Alt] key on alphanumeric keyboard (option).
y On rare occasions, the drawing of retrieved images might not be updated when
playing MPEG-2 clips in the Review window or Comparison window. If this
occurs, close the Review window or Comparison window and try to play the
MPEG-2 clip again.
Q1E-EZ1204 31
Chapter 4 - Long time recording mode
#
Measurement Slideshow ■ Prev Page Next Page Sound Volume Chap List
# #
TIC File Operations Chap Jump Speed Filing To Multi Select Start Select End
#
Delete Trim ■ Prev Page Next Page Sound Volume Chap List
File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).
Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.
32 Q1E-EZ1204
Chapter 4 - Long time recording mode
Select Start : It is possible to use this when clip single image playback
is displayed.
Select End : It is possible to use this when clip single image playback
is displayed.
You can play back the Doppler sound only when playing back the clip at normal
speed.
Q1E-EZ1204 33
Chapter 4 - Long time recording mode
#
File Operations Speed Filing To Single
# #
Measurement Images ■ Prev Page Next Page Sound Volume Chap List
File Operations : Press the File Operations button File Operations to display
more screen buttons (Delete and Trimming).
Delete : Deletes the currently displayed clip. For details, see the
subsection Filing function screen buttons in the chapter
Filing Function in the separate INSTRUCTION MANUAL
HI VISION Avius Operation.
34 Q1E-EZ1204
Chapter 4 - Long time recording mode
Q1E-EZ1204 35
Chapter 4 - Long time recording mode
36 Q1E-EZ1204
Chapter 5 - Specifications
Chapter 5 - Specifications
5.1 Clip capture mode
5.1.1 Common···································································································
Preset 8 types
Playback speed
Play 1×
Rewind -1×
y Biomedical waveform display unit is required for R trigger capture, and R-R
capture.
y To select DICOM or DICOM JPEG (lossy) for the image format, the optional
DICOM Software (Transfer and Media Storage) is required.
Capture rate
R trigger 30Fr/s
Q1E-EZ1204 37
Chapter 5 - Specifications
Capture time
Free
R trigger 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 beat
Capture time
38 Q1E-EZ1204
Chapter 5 - Specifications
Playback speed
Play 1×
y Clip capture mode and Long time recording mode cannot be used at the same
time.
y Ultrasound diagnostic scanners are other modes (For example EUB Series, HI
VISION 900) cannot play back the clips captured with this software or
manipulate the record files. And the clips captured by other model Ultrasound
Diagnostic Scanner (For example EUB Series, HI VISION 900) cannot be
played back and operated on HI VISION Avius.
Q1E-EZ1204 39
Chapter 5 - Specifications
40 Q1E-EZ1204
Appendix A - Playback Clips with PC
Windows 8.1
Windows 8 Pro
Windows 8
Ultimate
Professional
Windows 7 Home Premium
Motion JPEG can be played
Home Basic back without installing any
Starter CODEC.
Ultimate
Home Premium
Windows Vista
Business
Home Basic
Professional
Windows XP
Home Edition
Q1E-EZ1204 41
Appendix A - Playback Clips with PC
PowerPoint 2013
PowerPoint 2003
It is possible to insert the clip of Motion JPEG into the slide of PowerPoint by below step.
PowerPoint 2003
1. On the [Insert] menu, point to [Movies and Sounds], and then click [Movie
from File].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.
PowerPoint 2007, 2010
1. On the [Insert] tab, in the [Media Clips] group, click the arrow under [Movie],
and then click [Movie from File].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.
PowerPoint 2013
1. On the [Insert] tab, in the [Media] group, click the arrow under [Video], and
then click [Video on My PC].
2. Select the movie file in the Insert Movie dialog box, and then click the OK
button.
42 Q1E-EZ1204
Appendix A - Playback Clips with PC
Ultimate
Windows 7 Professional It is possible to play back the
Home Premium MPEG-2 clip by using
Windows Media Player.
Ultimate
Windows Vista
Home Premium
The following table shows the confirmed combination of OS and DVD player software.
OS Edition DVD player software
Windows 8.1
Power DVD13
Windows 8 Pro
Windows 8
Home Basic
Windows 7
Starter
Professional
Windows XP
Home Edition
Q1E-EZ1204 43
Appendix A - Playback Clips with PC
y When you do playback the MPEG-2 video clip, the image quality (Sharpness /
Color Tone) and the aspect ratio depend on DVD player software and the
graphics board of the PC.
We recommend that you obtain evaluation copy of the DVD player software and
confirm the following contents before introduction.
■ Please do playback the MPEG-2 video clip with the DVD player software
and check the image quality (Sharpness / Color Tone) and aspect ratio do
not have any problem.
■ If you do playback the MPEG-2 video clip with Windows Media Player or
PowerPoint, please do playback the MPEG-2 video clip with the Windows
Media Player and check the image quality (Sharpness / Color Tone) and
aspect ratio do not have any problem.
y If you need the detailed information of the DVD player software used for
MPEG-2 playback, please ask to developer of each DVD player software and
PC.
PowerPoint 2013
It is possible to play back the MPEG-2 clip
PowerPoint 2010
by inserting Windows Media Player into
PowerPoint 2007 slide.
PowerPoint 2003
MPEG-2 can paste into PowerPoint by below steps with the environment that Windows
Media Player can playback.
PowerPoint 2003
1. Select [Object] from [Insert] menu.
2. Insert item list is shown with appeared the object insertion dialog box, then
select [Windows Media Player] and push OK button
3. Windows Media Player is inserted into slide, then right-click on the Windows
Media Player and select [Property] in menu.
4. Property dialog box appears, and then select (property page) item and push …
button that displayed right of item.
5. Property dialog box of Windows Media Player appears, then enter file name to
playback into [File or URL] item and push OK button to close Property dialog
box.
44 Q1E-EZ1204
Appendix A - Playback Clips with PC
Q1E-EZ1204 45
Appendix A - Playback Clips with PC
46 Q1E-EZ1204
Appendix B - Compress Rate of Clips
Q1E-EZ1204 47
Appendix B - Compress Rate of Clips
48 Q1E-EZ1204
INDEX
INDEX
Outline of Long time recording mode ........................23
A
Auto Chapter.............................................................. 27
P
Playback ...............................................................18, 30
C Playback Clips with PC..............................................41
Cautions ....................................................................... 1 Playback with Comparison window...........................35
Clip capture mode .................................................... 3, 7 Playback with Windows .............................................41
Purpose of use ..............................................................1
F
R
Features........................................................................ 3
F-Fout......................................................................... 10 R trigger .......................................................................9
Free .............................................................................. 8 Record ........................................................................29
Functional restrictions during long time recording .... 23 R-Rout ........................................................................10
Functional restrictions during long time recording to
DVD-RAM ............................................................ 24
S
Functional restrictions during long time recording to Screen buttons of multi image playback ....................34
USB HDD .............................................................. 24 Screen buttons of single image playback ...................32
Setting of capture condition .........................................7
I Setting of record condition .........................................25
Installation.................................................................... 5 Setting of start/stop recording ....................................24
Setting of the capture condition temporarily ..............14
L Setting of the record condition temporarily................28
Long time recording mode ................................. 2, 3, 23 Specifications .............................................................37
Standard Components...................................................5
O
V
Optional components ................................................... 5
Outline ......................................................................... 1 Video-clip information ...............................................32
Outline of Clip capture mode....................................... 7 Video-clips with Recording Errors.............................35
Q1E-EZ1204 49