Вы находитесь на странице: 1из 1

SPECIFICATION FOR LINE PIPE 41

9.11.3.2 The tolerances for wall thickness shall be as given in Table 11.

Table 11 — Tolerances for wall thickness

Wall thickness Tolerances a


t
mm (in) mm (in)

SMLS pipe b

+ 0,6 (0.024)
≤ 4,0 (0.157)
− 0,5 (0.020)
+ 0,150 t
> 4,0 (0.157) to < 25,0 (0.984)
– 0,125 t
+ 3,7 (0.146) or + 0,1 t, whichever is the greater
≥ 25,0 (0.984)
− 3,0 (0.120) or – 0,1 t, whichever is the greater

Welded pipe c,d

≤ 5,0 (0.197) ± 0,5 (0.020)


> 5,0 (0.197) to < 15,0 (0.591) ± 0,1 t
≥ 15,0 (0.591) ± 1,5 (0.060)
a If the purchase order specifies a minus tolerance for wall thickness smaller than the applicable value given in this table, the plus
tolerance for wall thickness shall be increased by an amount sufficient to maintain the applicable tolerance range.
b For pipe with D ≥ 355,6 mm (14.000 in) and t ≥ 25,0 mm (0.984 in), the wall-thickness tolerance locally may exceed the plus
tolerance for wall thickness by an additional 0,05 t, provided that the plus tolerance for mass (see 9.14) is not exceeded.
c The plus tolerance for wall thickness does not apply to the weld area.
d See 9.13.2 for additional restrictions.

--````,,,,,,,```,,`,``,,,,``,,`-`-`,,`,,`,`,,`---

Copyright American Petroleum Institute


Provided by IHS under license with API Licensee=PDVSA - Maracaibo site 3/9986712008, User=Barrera, Vicente
No reproduction or networking permitted without license from IHS Not for Resale, 05/02/2013 08:04:50 MDT