ANTENNA CELL 0
di atas antenna

ANTENNA CELL 1
di atas antenna

ANTENNA CELL 2
Dekat serial number

ANTENNA CELL 0
Dekat serial number

ANTENNA CELL 1
Dekat serial number

ANTENNA CELL 2
- VDC DCDU Load 8 to - VDC EMU/EMUB To DCDU
EMU/EMUB Load 8

+ VDC DCDU Load 8+A10 to + VDC EMU/EMUB to DCDU


EMU/EMUB Load 8

Cable Alarm To Door Open Cable Alarm To Temperatur


Detector

Cable Alarm To Smoke Cable Alarm To MSP Fail


Detector

Cable Alarm To Water Detector Cable Alarm To DC FAN


Label alarm atau
tambahan yang kurang
Cable Alarm To AC Removed Cable Alarm To L1

Cable Alarm To
Rect Fail Cable Alarm To L2

Cable Alarm To Rect High Cable Alarm To L3

Cable Alarm To Rect Low Cable Alarm To Fence Break

Cable Alarm To Genset Fail Cable Alarm To Grounding Cut


Label MCB di cover
Cable Alarm To Genset Run MCB Alarm - BTS Rectifier
RRU 900 CELL 0_GSM RRU 900 CELL 1_GSM RRU 900 CELL 2_GSM
DEKAT sn RRU

RRU 900 CELL 0_GSM RRU 900 CELL 1_GSM RRU 900 CELL 2_GSM

label di board
untuk MRFUD RFU 900 CELL 0_GSM RFU 900 CELL 1_GSM RFU 900 CELL 1_GSM

label di board
RFU 900 CELL 0-A_GSM RFU 900 CELL 0-B_GSM RFU 900 CELL 1-A_GSM
untuk MRFU
menggunakan
semirigid
RFU 900 CELL 1-B_GSM RFU 900 CELL 2-A_GSM RFU 900 CELL 2-B_GSM

GSM CELL 0-A GSM CELL 0-B GSM CELL 1-A


label feeder di
sisi bendingan

GSM CELL 1-B GSM CELL 2-A GSM CELL 2-B

GSM CELL 0-A GSM CELL 0-B GSM CELL 1-A


label feeder di
sisi BTS/FEP

GSM CELL 1-B GSM CELL 2-A GSM CELL 2-B

GSM CELL 0-A GSM CELL 0-B GSM CELL 1-A


label feeder di
sisi Antenna

GSM CELL 1-B GSM CELL 2-A GSM CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM 0_GSM 1_GSM 2_GSM sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM Grounding kit_Cell 0_GSM Grounding kit_Cell 1_GSM Grounding kit_Cell 2_GSM sisi busbar
label CPRI 900
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM Grounding RRU 900 Grounding RRU 900 Grounding RRU 900
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_GSM to Busbar Cell 01_GSM to Busbar Cell 2_GSM to Busbar
Grounding RRU
CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP 900/Cell 0_GSM 900/Cell 1_GSM 900/Cell 2_GSM
label CPRI 900
UBRI
disisi RRU
CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM

CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM
label CPRI 900
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM

label CPRI 900


label CPRI 900 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM label CPRI 900 UBRI
di UBRI to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM to
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 900/Cell 0_GSM to CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM label CPRI 900 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 900
UBRI
disisi RRU
CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM

CPRI RRU 900/Cell 0_GSM CPRI RRU 900/Cell 1_GSM CPRI RRU 900/Cell 2_GSM CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM
label CPRI 900
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC
CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM
to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM
Power RRU 900
GSM at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to RRU 900/Cell 0_GSM to RRU 900/Cell 1_GSM to RRU 900/Cell 2_GSM
to MRFU 900/Cell 0_GSM to MRFU 900/Cell 1_GSM to MRFU 900/Cell 2_GSM

Pwr RRU 900/Cell 0_GSM Pwr RRU 900/Cell 1_GSM Pwr RRU 900/Cell 2_GSM
CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 900
GSM at RRU
Pwr RRU 900/Cell 0_GSM Pwr RRU 900/Cell 1_GSM Pwr RRU 900/Cell 2_GSM
CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 900 UBRI
disisi MRFU
CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 900/Cell 0_GSM CPRI MRFU 900/Cell 1_GSM CPRI MRFU 900/Cell 2_GSM
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB
FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB GSM - BTS MCB GSM - BTS MCB GSM - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 1800 CELL 0_DCS RRU 1800 CELL 1_DCS RRU 1800 CELL 2_DCS
DEKAT sn RRU

RRU 1800 CELL 0_DCS RRU 1800 CELL 1_DCS RRU 1800 CELL 2_DCS

label di board
untuk MRFUD RFU 1800 CELL 0_DCS RFU 1800 CELL 1_DCS RFU 1800 CELL 1_DCS

label di board
RFU 1800 CELL 0-A_DCS RFU 1800 CELL 0-B_DCS RFU 1800 CELL 1-A_DCS
untuk MRFU
menggunakan
semirigid
RFU 1800 CELL 1-B_DCS RFU 1800 CELL 2-A_DCS RFU 1800 CELL 2-B_DCS

DCS CELL 0-A DCS CELL 0-B DCS CELL 1-A


label feeder di
sisi bendingan

DCS CELL 1-B DCS CELL 2-A DCS CELL 2-B

DCS CELL 0-A DCS CELL 0-B DCS CELL 1-A


label feeder di
sisi BTS/FEP

DCS CELL 1-B DCS CELL 2-A DCS CELL 2-B

DCS CELL 0-A DCS CELL 0-B DCS CELL 1-A


label feeder di
sisi Antenna

DCS CELL 1-B DCS CELL 2-A DCS CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS 0_DCS 1_DCS 2_DCS sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS Grounding kit_Cell 0_DCS Grounding kit_Cell 1_DCS Grounding kit_Cell 2_DCS sisi busbar
label CPRI 1800
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS Grounding RRU 1800 Grounding RRU 1800 Grounding RRU 1800
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_DCS to Busbar Cell 01_DCS to Busbar Cell 2_DCS to Busbar

Grounding RRU
CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP 1800/Cell 0_DCS 1800/Cell 1_DCS 1800/Cell 2_DCS
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS

CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS
label CPRI 1800
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS

label CPRI 1800 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS label CPRI 1800 UBRI
di UBRI to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS to
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 1800/Cell 0_DCS to CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS label CPRI 1800 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS

CPRI RRU 1800/Cell 0_DCS CPRI RRU 1800/Cell 1_DCS CPRI RRU 1800/Cell 2_DCS CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS
label CPRI 1800
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS
to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS
Power RRU 1800
DCS at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 1800/Cell 0_DCS to RRU 1800/Cell 1_DCS to RRU 1800/Cell 2_DCS CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 1800/Cell 0_DCS to MRFU 1800/Cell 1_DCS to MRFU 1800/Cell 2_DCS

Pwr RRU 1800/Cell 0_DCS Pwr RRU 1800/Cell 1_DCS Pwr RRU 1800/Cell 2_DCS
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 1800
DCS at RRU
Pwr RRU 1800/Cell 0_DCS Pwr RRU 1800/Cell 1_DCS Pwr RRU 1800/Cell 2_DCS
CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 1800 UBRI
disisi MRFU
CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 1800/Cell 0_DCS CPRI MRFU 1800/Cell 1_DCS CPRI MRFU 1800/Cell 2_DCS
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB DCS - BTS MCB DCS - BTS MCB DCS - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 2100 CELL 0_3G RRU 2100 CELL 1_3G RRU 2100 CELL 2_3G
DEKAT sn RRU

RRU 2100 CELL 0_3G RRU 2100 CELL 1_3G RRU 2100 CELL 2_3G

label di board
untuk MRFUD RFU 2100 CELL 0_3G RFU 2100 CELL 1_3G RFU 2100 CELL 1_3G

label di board
RFU 2100 CELL 0-A_3G RFU 2100 CELL 0-B_3G RFU 2100 CELL 1-A_3G
untuk MRFU
menggunakan
semirigid
RFU 2100 CELL 1-B_3G RFU 2100 CELL 2-A_3G RFU 2100 CELL 2-B_3G

3G CELL 0-A 3G CELL 0-B 3G CELL 1-A


label feeder di
sisi bendingan

3G CELL 1-B 3G CELL 2-A 3G CELL 2-A

3G CELL 0-A 3G CELL 0-B 3G CELL 1-A


label feeder di
sisi BTS/FEP

3G CELL 1-B 3G CELL 2-A 3G CELL 2-B

3G CELL 0-A 3G CELL 0-B 3G CELL 1-A


label feeder di
sisi Antenna

3G CELL 1-B 3G CELL 2-A 3G CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G 0_3G 1_3G 2_3G sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G Grounding kit_Cell 0_3G Grounding kit_Cell 1_3G Grounding kit_Cell 2_3G sisi busbar
label CPRI 2100
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to POWER CABLE >> label power
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G DCDU /BTS DCDU/BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G Grounding RRU 2100 Grounding RRU 2100 Grounding RRU 2100
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_3G to Busbar Cell 01_3G to Busbar Cell 2_3G to Busbar
Grounding RRU
CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP 2100/Cell 0_3G 2100/Cell 1_3G 2100/Cell 2_3G
label CPRI 2100
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G

CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G
label CPRI 2100
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G

label CPRI 2100 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G label CPRI 2100 UBRI
di UBRI to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G to
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 2100/Cell 0_3G to CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G label CPRI 2100 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 2100
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G

CPRI RRU 2100/Cell 0_3G CPRI RRU 2100/Cell 1_3G CPRI RRU 2100/Cell 2_3G CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G
label CPRI 2100
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G
to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G
Power RRU 2100
3G at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 2100/Cell 0_3G to RRU 2100/Cell 1_3G to RRU 2100/Cell 2_3G CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 2100/Cell 0_3G to MRFU 2100/Cell 1_3G to MRFU 2100/Cell 2_3G

Pwr RRU 2100/Cell 0_3G Pwr RRU 2100/Cell 1_3G Pwr RRU 2100/Cell 2_3G
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 2100
3G at RRU
Pwr RRU 2100/Cell 0_3G Pwr RRU 2100/Cell 1_3G Pwr RRU 2100/Cell 2_3G
CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 2100 UBRI
disisi MRFU
CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 2100/Cell 0_3G CPRI MRFU 2100/Cell 1_3G CPRI MRFU 2100/Cell 2_3G
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB
FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB 3G - BTS MCB 3G - BTS MCB 3G - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 1800 CELL 0_LTE RRU 1800 CELL 1_LTE RRU 1800 CELL 2_LTE
DEKAT sn RRU

RRU 1800 CELL 0_LTE RRU 1800 CELL 1_LTE RRU 1800 CELL 2_LTE

label di board
untuk MRFUD RFU 1800 CELL 0_LTE RFU 1800 CELL 1_LTE RFU 1800 CELL 1_LTE

label di board
RFU 1800 CELL 0-A_LTE RFU 1800 CELL 0-B_LTE RFU 1800 CELL 1-A_LTE
untuk MRFU
menggunakan
semirigid
RFU 1800 CELL 1-B_LTE RFU 1800 CELL 2-A_LTE RFU 1800 CELL 2-B_LTE

LTE CELL 0-A LTE CELL 0-B LTE CELL 1-A


label feeder di
sisi bendingan

LTE CELL 1-B LTE CELL 2-A LTE CELL 2-B

LTE CELL 0-A LTE CELL 0-B LTE CELL 2-B


label feeder di
sisi BTS/FEP

LTE CELL 1-B LTE CELL 2-A LTE CELL 0-A

LTE CELL 0-A LTE CELL 0-B LTE CELL 1-A


label feeder di
sisi Antenna

LTE CELL 1-B LTE CELL 2-A LTE CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE 0_LTE 1_LTE 2_LTE

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE Grounding kit_Cell 0_LTE Grounding kit_Cell 1_LTE Grounding kit_Cell 2_LTE
label CPRI 1800
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >>
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE DCDU /BTS DCDU 2 >>

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to Rectifier to Rectifier << DCDU 1

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE Grounding RRU 1800 Grounding RRU 1800 Grounding RRU 1800
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_LTE to Busbar Cell 01_LTE to Busbar Cell 2_LTE to Busbar

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP 1800/Cell 0_LTE 1800/Cell 1_LTE 1800/Cell 2_LTE
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE
CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

label CPRI 1800 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
di UBRI to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE to
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

AC L1 Failure DC High Voltage Door Open Recti AC L1 Failure DC High Voltage Door Open Recti

AC L2 Failure DC Low Voltage AC L2 Failure DC Low Voltage

ALARM

AC L3 Failure Battery Stolen AC L3 Failure Battery Stolen

Rectifier Failure Door Open BTS Rectifier Failure Door Open BTS

Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE
to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE
Power RRU 1800
LTE at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

Pwr RRU 1800/Cell 0_LTE Pwr RRU 1800/Cell 1_LTE Pwr RRU 1800/Cell 2_LTE
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 1800
LTE at RRU
Pwr RRU 1800/Cell 0_LTE Pwr RRU 1800/Cell 1_LTE Pwr RRU 1800/Cell 2_LTE
CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI

CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB
FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU

Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1


PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB LTE - BTS MCB LTE - BTS MCB LTE - BTS FE/GE 0 FE/GE 1 FE/GE 1
groundingkit
sisi power

groundingkit
sisi busbar

label power
to DCDU 1

Kabel DCDU

Grounding RRU

label CPRI 1800


di UBBP
label CPRI 1800 UBRI
disisi MRFU

label CPRI 1800 UBRI


disisi MRFU

label CPRI 1800


di UBRI

label CPRI 1800 UBRI


disisi MRFU

Label CPRI/ETH
at BBU
RRU 1800 CELL 0_LTE RRU 1800 CELL 1_LTE RRU 1800 CELL 2_LTE
DEKAT sn RRU

RRU 1800 CELL 0_LTE RRU 1800 CELL 1_LTE RRU 1800 CELL 2_LTE

label di board
untuk MRFUD RFU 1800 CELL 0_LTE RFU 1800 CELL 1_LTE RFU 1800 CELL 1_LTE

LTE CELL 0-A LTE CELL 1-A LTE CELL 2-A

LTE CELL 0-B LTE CELL 1-B LTE CELL 2-B


Label jumper Sisi
antenna

LTE CELL 0-C LTE CELL 1-C LTE CELL 2-C

LTE CELL 0-D LTE CELL 1-D LTE CELL 2-D

LTE CELL 0-A LTE CELL 1-A LTE CELL 2-A

LTE CELL 0-B LTE CELL 1-B LTE CELL 2-B


Label jumper sisi
RRU

LTE CELL 0-C LTE CELL 1-C LTE CELL 2-C

LTE CELL 0-D LTE CELL 1-D LTE CELL 2-D


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE 0_LTE 1_LTE 2_LTE sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE Grounding kit_Cell 0_LTE Grounding kit_Cell 1_LTE Grounding kit_Cell 2_LTE sisi busbar
label CPRI 1800
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE Grounding RRU 1800 Grounding RRU 1800 Grounding RRU 1800
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_LTE to Busbar Cell 01_LTE to Busbar Cell 2_LTE to Busbar

Busbar To Grounding RRU Grounding RRU


Busbar To Grounding RRU
CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE Busbar To Grounding RRU 1800/Cell 1_LTE 1800/Cell 2_LTE
1800/Cell 0_LTE
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE
label CPRI 1800
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

label CPRI 1800 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE label CPRI 1800 UBRI
di UBRI to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE to
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 1800/Cell 0_LTE to CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE label CPRI 1800 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

CPRI RRU 1800/Cell 0_LTE CPRI RRU 1800/Cell 1_LTE CPRI RRU 1800/Cell 2_LTE CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE
label CPRI 1800
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE
to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE
Power RRU 1800
LTE at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 1800/Cell 0_LTE to RRU 1800/Cell 1_LTE to RRU 1800/Cell 2_LTE CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 1800/Cell 0_LTE to MRFU 1800/Cell 1_LTE to MRFU 1800/Cell 2_LTE

Pwr RRU 1800/Cell 0_LTE Pwr RRU 1800/Cell 1_LTE Pwr RRU 1800/Cell 2_LTE
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 1800
LTE at RRU
Pwr RRU 1800/Cell 0_LTE Pwr RRU 1800/Cell 1_LTE Pwr RRU 1800/Cell 2_LTE
CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 1800 UBRI
disisi MRFU
CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 1800/Cell 0_LTE CPRI MRFU 1800/Cell 1_LTE CPRI MRFU 1800/Cell 2_LTE
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB LTE - BTS MCB LTE - BTS MCB LTE - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 900 CELL 0_U900 RRU 900 CELL 1_U900 RRU 900 CELL 2_U900
DEKAT sn RRU

RRU 900 CELL 0_U900 RRU 900 CELL 1_U900 RRU 900 CELL 2_U900

label di board
untuk MRFUD RFU 900 CELL 0_U900 RFU 900 CELL 1_U900 RFU 900 CELL 1_U900

label di board
RFU 900 CELL 0-A_U900 RFU 900 CELL 0-B_U900 RFU 900 CELL 1-A_U900
untuk MRFU
menggunakan
semirigid
RFU 900 CELL 1-B_U900 RFU 900 CELL 2-A_U900 RFU 900 CELL 2-B_U900

U900 CELL 0-A U900 CELL 0-B U900 CELL 1-A


label feeder di
sisi bendingan

U900 CELL 1-B U900 CELL 2-A U900 CELL 2-B

U900 CELL 0-A U900 CELL 0-B U900 CELL 1-A


label feeder di
sisi BTS/FEP

U900 CELL 1-B U900 CELL 2-A U900 CELL 2-B

U900 CELL 0-A U900 CELL 0-B U900 CELL 1-A


label feeder di
sisi Antenna

U900 CELL 1-B U900 CELL 2-A U900 CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 0_U900 1_U900 2_U900 sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 Grounding kit_Cell 0_U900 Grounding kit_Cell 1_U900 Grounding kit_Cell 2_U900 sisi busbar
label CPRI 900
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 Grounding RRU 900 Grounding RRU 900 Grounding RRU 900
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_U900 to Busbar Cell 01_U900 to Busbar Cell 2_U900 to Busbar

Busbar To Grounding RRU Grounding RRU


Busbar To Grounding RRU
CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 Busbar To Grounding RRU 900/Cell 1_U900 900/Cell 2_U900
900/Cell 0_U900
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP
label CPRI 900
UBRI
disisi RRU
CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900

CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900
label CPRI 900
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900

label CPRI 900 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900 label CPRI 900 UBRI
di UBRI to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900 to
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 900/Cell 0_U900 to CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900 label CPRI 900 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 900
UBRI
disisi RRU
CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900

CPRI RRU 900/Cell 0_U900 CPRI RRU 900/Cell 1_U900 CPRI RRU 900/Cell 2_U900 CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900
label CPRI 900
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900
to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900
Power RRU 900
U900 at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 900/Cell 0_U900 to RRU 900/Cell 1_U900 to RRU 900/Cell 2_U900 CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 900/Cell 0_U900 to MRFU 900/Cell 1_U900 to MRFU 900/Cell 2_U900

Pwr RRU 900/Cell 0_U900 Pwr RRU 900/Cell 1_U900 Pwr RRU 900/Cell 2_U900
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 900
U900 at RRU
Pwr RRU 900/Cell 0_U900 Pwr RRU 900/Cell 1_U900 Pwr RRU 900/Cell 2_U900
CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 900 UBRI
disisi MRFU
CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 900/Cell 0_U900 CPRI MRFU 900/Cell 1_U900 CPRI MRFU 900/Cell 2_U900
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB U900 - BTS MCB U900 - BTS MCB U900 - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 2100 CELL 0_LTE RRU 2100 CELL 1_LTE RRU 2100 CELL 2_LTE
DEKAT sn RRU

RRU 2100 CELL 0_LTE RRU 2100 CELL 1_LTE RRU 2100 CELL 2_LTE

label di board
untuk MRFUD RFU 2100 CELL 0_LTE RFU 2100 CELL 1_LTE RFU 2100 CELL 1_LTE

label di board
RFU 2100 CELL 0-A_LTE RFU 2100 CELL 0-B_LTE RFU 2100 CELL 1-A_LTE
untuk MRFU
menggunakan
semirigid
RFU 2100 CELL 1-B_LTE RFU 2100 CELL 2-A_LTE RFU 2100 CELL 2-B_LTE

LTE CELL 0-A LTE CELL 0-B LTE CELL 1-A


label feeder di
sisi bendingan

LTE CELL 1-B LTE CELL 2-A LTE CELL 2-B

LTE CELL 0-A LTE CELL 0-B LTE CELL 1-A


label feeder di
sisi BTS/FEP

LTE CELL 1-B LTE CELL 2-A LTE CELL 2-B

LTE CELL 0-A LTE CELL 0-B LTE CELL 1-A


label feeder di
sisi Antenna

LTE CELL 1-B LTE CELL 2-A LTE CELL 2-B


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE 0_LTE 1_LTE 2_LTE sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE Grounding kit_Cell 0_LTE Grounding kit_Cell 1_LTE Grounding kit_Cell 2_LTE sisi busbar
label CPRI 1800
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE Grounding RRU 2100 Grounding RRU 2100 Grounding RRU 2100
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_LTE to Busbar Cell 01_LTE to Busbar Cell 2_LTE to Busbar

Busbar To Grounding RRU Grounding RRU


Busbar To Grounding RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE Busbar To Grounding RRU 2100/Cell 1_LTE 2100/Cell 2_LTE
2100/Cell 0_LTE
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
label CPRI 1800
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

label CPRI 1800 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE label CPRI 1800 UBRI
di UBRI to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE to
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 2100/Cell 0_LTE to CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE label CPRI 1800 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
label CPRI 1800
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE
to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
Power RRU 1800
LTE at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

Pwr RRU 2100/Cell 0_LTE Pwr RRU 2100/Cell 1_LTE Pwr RRU 2100/Cell 2_LTE
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 1800
LTE at RRU
Pwr RRU 2100/Cell 0_LTE Pwr RRU 2100/Cell 1_LTE Pwr RRU 2100/Cell 2_LTE
CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 1800 UBRI
disisi MRFU
CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB LTE - BTS MCB LTE - BTS MCB LTE - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 2100 CELL 0_LTE RRU 2100 CELL 1_LTE RRU 2100 CELL 2_LTE
DEKAT sn RRU

RRU 2100 CELL 0_LTE RRU 2100 CELL 1_LTE RRU 2100 CELL 2_LTE

label di board
untuk MRFUD RFU 2100 CELL 0_LTE RFU 2100 CELL 1_LTE RFU 2100 CELL 1_LTE

LTE CELL 0-A LTE CELL 1-A LTE CELL 2-A

LTE CELL 0-B LTE CELL 1-B LTE CELL 2-B


Label jumper Sisi
antenna

LTE CELL 0-C LTE CELL 1-C LTE CELL 2-C

LTE CELL 0-D LTE CELL 1-D LTE CELL 2-D

LTE CELL 0-A LTE CELL 1-A LTE CELL 2-A

LTE CELL 0-B LTE CELL 1-B LTE CELL 2-B


Label jumper sisi
RRU

LTE CELL 0-C LTE CELL 1-C LTE CELL 2-C

LTE CELL 0-D LTE CELL 1-D LTE CELL 2-D


CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell Grounding kit To Busbar_Cell groundingkit
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE 0_LTE 1_LTE 2_LTE sisi power

CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE Grounding kit_Cell 0_LTE Grounding kit_Cell 1_LTE Grounding kit_Cell 2_LTE sisi busbar
label CPRI 1800
di UBBP
CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE Grounding RRU 2100 Grounding RRU 2100 Grounding RRU 2100
to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP Cell 0_LTE to Busbar Cell 01_LTE to Busbar Cell 2_LTE to Busbar

Busbar To Grounding RRU Grounding RRU


Busbar To Grounding RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE Busbar To Grounding RRU 2100/Cell 1_LTE 2100/Cell 2_LTE
2100/Cell 0_LTE
to CPRI_3/UBBP to CPRI_4/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
label CPRI 1800
di UBBP
CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI CPRI_0/UBBP CPRI_2/UBBP CPRI_4/UBBP
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI CPRI_1/UBBP CPRI_3/UBBP CPRI_5/UBBP


to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

label CPRI 1800 CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE label CPRI 1800 UBRI
di UBRI to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to CPRI_0/UBBP to CPRI_1/UBBP to CPRI_2/UBBP disisi MRFU
di UBRI

CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE to
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE to CPRI_3/UBBP to CPRI_4/UBBP CPRI_5/UBBP

CPRI RRU 2100/Cell 0_LTE to CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE label CPRI 1800 UBRI
CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI to CPRI_0/UBBP to CPRI_2/UBBP to CPRI_4/UBBP disisi MRFU

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI to CPRI_1/UBBP to CPRI_3/UBBP to CPRI_5/UBBP
label CPRI 1800
UBRI
disisi RRU
CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_0/UBRI CPRI_1/UBRI CPRI_2/UBRI
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

CPRI RRU 2100/Cell 0_LTE CPRI RRU 2100/Cell 1_LTE CPRI RRU 2100/Cell 2_LTE CPRI_3/UBRI CPRI_4/UBRI CPRI_5/UBRI
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
label CPRI 1800
di UBRI
Pwr DCDU Load_0/RFC Pwr DCDU Load_1/RFC Pwr DCDU Load_2/RFC CPRI_0/UBRI CPRI_2/UBRI CPRI_4/UBRI
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE
to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE
Power RRU 1800
LTE at DCDU
Pwr DCDU Load_3/RFC Pwr DCDU Load_4/RFC Pwr DCDU Load_5/RFC
to RRU 2100/Cell 0_LTE to RRU 2100/Cell 1_LTE to RRU 2100/Cell 2_LTE CPRI_1/UBRI CPRI_3/UBRI CPRI_5/UBRI
to MRFU 2100/Cell 0_LTE to MRFU 2100/Cell 1_LTE to MRFU 2100/Cell 2_LTE

Pwr RRU 2100/Cell 0_LTE Pwr RRU 2100/Cell 1_LTE Pwr RRU 2100/Cell 2_LTE
to DCDU Load_0/RFC to DCDU Load_1/RFC to DCDU Load_2/RFC CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI
Power RRU 1800
LTE at RRU
Pwr RRU 2100/Cell 0_LTE Pwr RRU 2100/Cell 1_LTE Pwr RRU 2100/Cell 2_LTE
CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to DCDU Load_3/RFC to DCDU Load_4/RFC to DCDU Load_5/RFC
to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI
label CPRI 1800 UBRI
disisi MRFU
CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

CPRI MRFU 2100/Cell 0_LTE CPRI MRFU 2100/Cell 1_LTE CPRI MRFU 2100/Cell 2_LTE
Power BBU 1 to DCDU Power BBU 2 to DCDU Power DCDU 2 to BBU
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
Power BBU 1 to DCDU Power BBU 2 to DCDU Power DCDU 2 to BBU
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
Power DCDU 1 to BBU Power DCDU 1 to BBU PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB LTE - BTS MCB LTE - BTS MCB LTE - BTS FE/GE 0 FE/GE 1 FE/GE 1
RRU 900/1800 CELL 0 RRU 900/1800 CELL 1 RRU 900/1800 CELL 2
DEKAT sn RRU

RRU 900/1800 CELL 0 RRU 900/1800 CELL 1 RRU 900/1800 CELL 2

label di board
untuk MRFUD RRU 900/1800 CELL 0 RRU 900/1800 CELL 1 RRU 900/1800 CELL 2

CELL 0-A CELL 1-A CELL 2-A

CELL 0-B CELL 1-B CELL 2-B


Label jumper Sisi
antenna

CELL 0-C CELL 1-C CELL 2-C

CELL 0-D CELL 1-D CELL 2-D

CELL 0-A CELL 1-A CELL 2-A

CELL 0-B CELL 1-B CELL 2-B


Label jumper sisi
RRU

CELL 0-C CELL 1-C CELL 2-C

CELL 0-D CELL 1-D CELL 2-D


CPRI_0-UBBP CPRI_1-UBBP CPRI_2-UBBP Grounding kit To Busbar_Cell 0 Grounding kit To Busbar_Cell 1 Grounding kit To Busbar_Cell 2 groundingkit
to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 sisi power

CPRI_3-UBBP CPRI_4-UBBP CPRI_5-UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 Grounding kit_Cell 0 Grounding kit_Cell 1 Grounding kit_Cell 2 sisi busbar
label CPRI RRU
5909
di UBBP
CPRI_0-UBBP CPRI_2-UBBP CPRI_4-UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1-UBBP CPRI_3-UBBP CPRI_5-UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 900/1800-Cell 0 CPRI RRU 900/1800-Cell 1 CPRI RRU 900/1800-Cell 2_ Grounding RRU 5909 Grounding RRU 5909 Grounding RRU 5909
to CPRI_0-UBBP to CPRI_1-UBBP to CPRI_2-UBBP Cell 0_LTE to Busbar Cell 01_LTE to Busbar Cell 2_LTE to Busbar

Grounding RRU
CPRI RRU 900/1800-Cell 0 CPRI RRU 900/1800-Cell 1 CPRI RRU 900/1800-Cell 2_ Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
5909/Cell 0
to CPRI_3-UBBP to CPRI_4-UBBP to CPRI_5-UBBP 5909/Cell 1 5909/Cell 2
label CPRI RRU
5909 UBRI
disisi RRU
CPRI RRU 900/1800-Cell 0 CPRI RRU 900/1800-Cell 1 CPRI RRU 900/1800-Cell 2_ CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0-UBBP to CPRI_2-UBBP to CPRI_4-UBBP to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2

CPRI RRU 900/1800-Cell 0 CPRI RRU 900/1800-Cell 1 CPRI RRU 900/1800-Cell 2_ CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1-UBBP to CPRI_3-UBBP to CPRI_5-UBBP to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2
label CPRI
di UBBP TO MRFU
CPRI_0-UBRI CPRI_1-UBRI CPRI_2-UBRI CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to RRU 900/1800-Cell 0_LTE to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2

CPRI_3-UBRI CPRI_4-UBRI CPRI_5-UBRI CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP


to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/18000-Cell 2 to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2
label CPRI 5909
di UBRI
CPRI_0-UBRI CPRI_1-UBRI CPRI_2-UBRI CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2 label CPRI UBRI
to RRU 900/1800-Cell 0_LTE to RRU 900/1800-Cell 1 to RRU 900/1800-Cell 2 to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI disisi MRFU
CPRI_3-UBRI CPRI_4-UBRI CPRI_5-UBRI CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2 label CPRI UBRI
to RRU 900/1800-Cell 0 to RRU 900/1800-Cell 1 to RRU 900/18000-Cell 2 to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI disisi MRFU

CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2


to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB BTS MCB BTS MCB BTS FE/GE 0 FE/GE 1 FE/GE 1

- 48 VDC DCDU
DCDU 12B +48 VDC Rectifier to DCDU to Rectifier

DCDU 12B +48 VDC Rectifier to DCDU - 48 VDC DCDU


to Rectifier

Pwr DCDU Load_0 Pwr DCDU Load_1 Pwr DCDU Load_2


to RRU 900/1800_Cell 0 to RRU 900/1800_Cell 1 to RRU 900/1800_Cell 0
Power RRU 5909
at EPU02D
Pwr DCDU Load_3 Pwr DCDU Load_4 Pwr DCDU Load_5
to RRU 900/1800_Cell 4 to RRU 900/1800_Cell 5 to RRU 900/1800_Cell 6

Pwr RRU 900/1800_Cell 0 TO Pwr RRU 900/1800_Cell 1 TO Pwr RRU 900/1800_Cell 2 TO


DCDU Load 0 DCDU Load 1 DCDU Load 2
Power RRU 5509
at RRU
Pwr RRU 900/1800_Cell 4 TO Pwr RRU 900/1800_Cell 5 TO Pwr RRU 900/1800_Cell 6 TO
DCDU Load 4 DCDU Load 5 DCDU Load 6
RRU 1800-2100 CELL 0 RRU 1800-2100 CELL 1 RRU 1800-2100 CELL 2
DEKAT sn RRU

RRU 1800-2100 CELL 0 RRU 1800-2100 CELL 1 RRU 1800-2100 CELL 2


RRU 1800-2100 CELL 1 RRU 1800-2100 CELL 2
label di board
untuk MRFUD RRU 1800-2100 CELL 0 RRU 1800-2100 CELL 1 RRU 1800-2100 CELL 2

CELL 0-A CELL 1-A CELL 2-A

CELL 0-B CELL 1-B CELL 2-B


Label jumper Sisi
antenna

CELL 0-C CELL 1-C CELL 2-C

CELL 0-D CELL 1-D CELL 2-D

CELL 0-A CELL 1-A CELL 2-A

CELL 0-B CELL 1-B CELL 2-B


Label jumper sisi
RRU

CELL 0-C CELL 1-C CELL 2-C

CELL 0-D CELL 1-D CELL 2-D


CPRI_0-UBBP CPRI_1-UBBP CPRI_2-UBBP Grounding kit To Busbar_Cell 0 Grounding kit To Busbar_Cell 1 Grounding kit To Busbar_Cell 2 groundingkit
to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 sisi power

CPRI_3-UBBP CPRI_4-UBBP CPRI_5-UBBP Busbar To Busbar To Busbar To groundingkit


to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 Grounding kit_Cell 0 Grounding kit_Cell 1 Grounding kit_Cell 2 sisi busbar
label CPRI RRU
5502
di UBBP
CPRI_0-UBBP CPRI_2-UBBP CPRI_4-UBBP - 48 VDC Rectifier to +48 VDC Rectifier to DCDU/BTS POWER CABLE >> label power
to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 DCDU /BTS DCDU 2 >> to DCDU 1

CPRI_1-UBBP CPRI_3-UBBP CPRI_5-UBBP - 48 VDC DCDU/BTS + 48 DCDU/BTS << POWER CABLE


to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 to Rectifier to Rectifier << DCDU 1 Kabel DCDU

CPRI RRU 1800 & 2100-Cell 0 CPRI RRU 1800 & 2100-Cell 1 CPRI RRU 1800 & 2100-Cell 2_ Grounding RRU 5502 Grounding RRU 5502 Grounding RRU 5502
to CPRI_0-UBBP to CPRI_1-UBBP to CPRI_2-UBBP Cell 0 to Busbar Cell 1 to Busbar Cell 2 to Busbar

Grounding RRU
CPRI RRU 1800 & 2100-Cell 0 CPRI RRU 1800 & 2100-Cell 1 CPRI RRU 1800 & 2100-Cell 2_ Busbar To Grounding RRU Busbar To Grounding RRU Busbar To Grounding RRU
5502/Cell 0
to CPRI_3-UBBP to CPRI_4-UBBP to CPRI_5-UBBP 5502/Cell 1 5502/Cell 2
label CPRI RRU
5502 UBRI
disisi RRU
CPRI RRU 1800 & 2100-Cell 0 CPRI RRU 1800 & 2100-Cell 1 CPRI RRU 1800 & 2100-Cell 2_ CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to CPRI_0-UBBP to CPRI_2-UBBP to CPRI_4-UBBP to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2

CPRI RRU 1800 & 2100-Cell 0 CPRI RRU 1800 & 2100-Cell 1 CPRI RRU 1800 & 2100-Cell 2_ CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP
to CPRI_1-UBBP to CPRI_3-UBBP to CPRI_5-UBBP to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2
label CPRI
di UBBP TO MRFU
CPRI_0-UBRI CPRI_1-UBRI CPRI_2-UBRI CPRI_0/UBBP CPRI_1/UBBP CPRI_2/UBBP
to RRU 1800 & 2100-Cell
to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2
0_LTE

CPRI_3-UBRI CPRI_4-UBRI CPRI_5-UBRI CPRI_3/UBBP CPRI_4/UBBP CPRI_5/UBBP


to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 21000-Cell 2 to MRFU 2100/Cell 0 to MRFU 2100/Cell 1 to MRFU 2100/Cell 2
label CPRI 5502
di UBRI CPRI_0-UBRI
to RRU 1800 & 2100-Cell CPRI_1-UBRI CPRI_2-UBRI CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2 label CPRI UBRI
0_LTE to RRU 1800 & 2100-Cell 1 to RRU 1800 & 2100-Cell 2 to CPRI_0/UBRI to CPRI_1/UBRI to CPRI_2/UBRI disisi MRFU
CPRI_3-UBRI CPRI_4-UBRI CPRI_5-UBRI CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2 label CPRI UBRI
to RRU 1800 & 2100-Cell 0 to RRU 1800 & 2100-Cell 1 to RRU 1800 & 21000-Cell 2 to CPRI_3/UBRI to CPRI_4/UBRI to CPRI_5/UBRI disisi MRFU

CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2


to CPRI_0/UBRI to CPRI_2/UBRI to CPRI_4/UBRI

PGND DCDU to Busbar PGND BBU to Busbar PGND EMUB to Busbar CPRI MRFU 2100/Cell 0 CPRI MRFU 2100/Cell 1 CPRI MRFU 2100/Cell 2
to CPRI_1/UBRI to CPRI_3/UBRI to CPRI_5/UBRI

CPRI UMPT FE/GE 0/BBU CPRI UMPT FE/GE 1/BBU CPRI UMPT FE/GE 1/BBU
PGND Busbar to DCDU PGND Busbar to BBU PGND Busbar to EMUB
to TRM FE/GE to TRM FE/GE to TRM FE/GE
Grounding
module
CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT CPRI TRM FE/GE to UMPT
PGND Busbar to EMUA PGND RFC to EGB PGND BTS to EGB/IGB FE/GE 0/BBU FE/GE 1/BBU FE/GE 1/BBU
Label CPRI/ETH
at BBU
Ethernet /UMPT FE/GE 0 Ethernet /UMPT FE/GE 1 Ethernet /UMPT FE/GE 1
PGND EMUA to Busbar PGND EGB to RFC PGND EGB/IGB to BTS
to TRM FE/GE to TRM FE/GE to TRM FE/GE

Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT Ethernet TRM FE/GE to UMPT
MCB MCB BTS MCB BTS MCB BTS FE/GE 0 FE/GE 1 FE/GE 1

+48 VDC Rectifier to - 48 VDC EPU02D/BTS


DCDU EPU02D
EPU02D/BTS to Rectifier

+48 VDC Rectifier to - 48 VDC EPU02D/BTS


DCDU EPU02D EPU02D/BTS to Rectifier

Pwr RRU 1800&2100/Cell 0 Pwr RRU 1800&2100/Cell 1 Pwr RRU 1800&2100/Cell 2


to EPU02D Slot 1_Load 0 to EPU02D Slot 1_Load 1 to EPU02D Slot 2_Load 0
Power RRU 5502
at RRU Pwr RRU 1800&2100/Cell 4
to EPU02D Slot 2_Load 1

Pwr EPU02D Slot1_Load 0 Pwr EPU02D Slot1_Load 1 Pwr EPU02D Slot2_Load 0


to RRU 1800&2100/Cell 0 to RRU 1800&2100/Cell 1 to RRU 1800&2100/Cell 2
Power RRU 5502
at EPU02D
Pwr EPU02D Slot2_Load 1
to RRU 1800&2100/Cell 4