7 CM2350 B121B – Engine Model Year 2017

Table of Contents
1. 2623.3-SE1378: Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................... 33
2. 2623.4-SE1379: Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage Below Normal or
Shorted to Low Source ................................................................................................................................ 34
3. 167.16-SE378: Electrical Charging System Voltage - Data Valid But Above Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 35
4. 167.18-SE379: Electrical Charging System Voltage - Data Valid But Below Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 36
5. 171.2-SE3799: Ambient Air Temperature - Data Erratic, Intermittent, or Incorrect .......................... 37
6. 171.2-SE3871: Ambient Air Temperature - Data Erratic, Intermittent, or Incorrect .......................... 38
7. 171.3-SE3802: Ambient Air Temperature Sensor 1 Circuit - Voltage Above Normal or Shorted to
High Source ................................................................................................................................................. 39
8. 171.4-SE3803: Ambient Air Temperature Sensor 1 Circuit - Voltage Below Normal or Shorted to Low
Source ......................................................................................................................................................... 40
9. 5571.7-SE5446: High Pressure Common Rail Fuel Pressure Relief Valve - Mechanical System Not
Responding or Out of Adjustment .............................................................................................................. 41
10. 5571.0-SE914: High Pressure Common Rail Fuel Pressure Relief Valve - Data Valid But Above
Normal Operating Range - Most Severe Level ............................................................................................ 42
11. 157.16-SE522: Injector Metering Rail 1 Pressure - Data Valid But Above Normal Operating Range
- Moderately Severe Level .......................................................................................................................... 43
12. 157.18-SE523: Injector Metering Rail 1 Pressure - Data Valid But Below Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 44
13. 1349.3-SE6690: Injector Metering Rail 2 Pressure Sensor Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................... 45
14. 1349.4-SE6691: Injector Metering Rail 2 Pressure Sensor Circuit - Voltage Below Normal or
Shorted to Low Source ................................................................................................................................ 46
15. 157.3-SE525: Injector Metering Rail 1 Pressure Sensor Circuit - Voltage Above Normal or Shorted
to High Source ............................................................................................................................................. 47
16. 157.4-SE526: Injector Metering Rail 1 Pressure Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ............................................................................................................................................. 48
17. 1347.2-SE915: Engine Fuel Pump Pressurizing Assembly 1 - Data Erratic, Intermittent, or Incorrect
........................................................................................................................................................ 49
18. 1347.3-SE965: Engine Fuel Pump Pressurizing Assembly 1 Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................... 50
19. 633.31-SE518: Electronic Fuel Injection Control Valve Circuit - Condition Exists........................... 51

Cummins Inc. Revision Date: March 30, 2017 1


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

20. 1347.4-SE966: Engine Fuel Pump Pressurizing Assembly 1 Circuit - Voltage Below Normal or
Shorted to Low Source ................................................................................................................................ 52
21. 168.15-SE297: Battery 1 Voltage - Data Valid But Above Normal Operating Range - Least Severe
Level ........................................................................................................................................................ 53
22. 168.17-SE296: Battery 1 Voltage - Data Valid But Below Normal Operating Range - Least Severe
Level ........................................................................................................................................................ 54
23. 101.2-SE2086: Crankcase Pressure - Data Erratic, Intermittent, or Incorrect ................................ 55
24. 1239.16-SE8484: Engine Fuel Leakage - Data Valid But Above Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 56
25. 157.15-SE8485: Injector Metering Rail 1 Pressure - Data Valid But Above Normal Operating Range
- Least Severe Level ..................................................................................................................................... 57
26. 5285.18-SE5250: Engine Charge Air Cooler Efficiency - Data Valid But Below Normal Operating
Range - Moderately Severe Level ............................................................................................................... 58
27. 101.2-SE3665: Crankcase Pressure - Data Erratic, Intermittent, or Incorrect ................................ 59
28. 101.15-SE5592: Crankcase Pressure - Data Valid But Above Normal Operating Range - Least
Severe Level ................................................................................................................................................ 60
29. 4752.18-SE3565: Engine Exhaust Gas Recirculation Cooler Efficiency - Data Valid But Below
Normal Operating Range - Moderately Severe Level ................................................................................. 61
30. 102.20-SE3651: Intake Manifold 1 Pressure - Data Not Rational - Drifted High ............................ 62
31. 102.21-SE3652: Intake Manifold 1 Pressure - Data Not Rational - Drifted Low ............................. 63
32. 102.2-SE4439: Intake Manifold 1 Pressure - Data Erratic, Intermittent, or Incorrect .................... 64
33. 102.3-SE489: Intake Manifold 1 Pressure Sensor Circuit - Voltage Above Normal or Shorted to
High Source ................................................................................................................................................. 65
34. 102.4-SE490: Intake Manifold 1 Pressure Sensor Circuit - Voltage Below Normal or Shorted to
Low Source .................................................................................................................................................. 66
35. 105.2-SE4070: Intake Manifold 1 Temperature - Data Erratic, Intermittent, or Incorrect............. 67
36. 105.2-SE3793: Intake Manifold 1 Temperature - Data Erratic, Intermittent, or Incorrect............. 68
37. 105.3-SE487: Intake Manifold 1 Temperature Sensor Circuit - Voltage Above Normal or Shorted
to High Source ............................................................................................................................................. 69
38. 105.4-SE488: Intake Manifold 1 Temperature Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ............................................................................................................................................. 70
39. 1176.2-SE8698: Turbocharger 1 Compressor Intake Pressure - Data Erratic, Intermittent, or
Incorrect ...................................................................................................................................................... 71
40. 1176.2-SE8699: Turbocharger 1 Compressor Intake Pressure - Data Erratic, Intermittent, or
Incorrect ...................................................................................................................................................... 72
41. 1176.2-SE8802: Turbocharger 1 Compressor Intake Pressure - Data Erratic, Intermittent, or
Incorrect ...................................................................................................................................................... 73

Cummins Inc. Revision Date: March 30, 2017 2


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

42. 1176.3-SE8365: Turbocharger 1 Compressor Intake Pressure Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................... 74
43. 1176.4-SE8366: Turbocharger 1 Compressor Intake Pressure Circuit - Voltage Below Normal or
Shorted to Low Source ................................................................................................................................ 75
44. 1172.2-SE4190: Turbocharger 1 Compressor Intake Temperature - Data Erratic, Intermittent, or
Incorrect ...................................................................................................................................................... 76
45. 1172.2-SE4746: Turbocharger 1 Compressor Intake Temperature - Data Erratic, Intermittent, or
Incorrect ...................................................................................................................................................... 77
46. 1172.3-SE486: Turbocharger 1 Compressor Intake Temperature Circuit - Voltage Above Normal
or Shorted to High Source........................................................................................................................... 78
47. 1172.4-SE484: Turbocharger 1 Compressor Intake Temperature Circuit - Voltage Below Normal
or Shorted to Low Source ........................................................................................................................... 79
48. 6303.3-SE7984: Engine Coolant Level 2 Sensor Circuit - Voltage Above Normal or Shorted to High
Source ........................................................................................................................................................ 80
49. 6303.4-SE7985: Engine Coolant Level 2 Sensor Circuit - Voltage Below Normal or Shorted to Low
Source ........................................................................................................................................................ 81
50. 111.3-SE572: Coolant Level Sensor 1 Circuit - Voltage Above Normal or Shorted to High Source 82
51. 111.4-SE283: Coolant Level Sensor 1 Circuit - Voltage Below Normal or Shorted to Low Source . 83
52. 111.18-SE3993: Coolant Level - Data Valid But Below Normal Operating Range - Moderately
Severe Level ................................................................................................................................................ 84
53. 110.15-SE80: Engine Coolant Temperature - Data Valid But Above Normal Operating Range -
Least Severe Level ....................................................................................................................................... 85
54. 110.3-SE75: Engine Coolant Temperature 1 Sensor Circuit - Voltage Above Normal or Shorted to
High Source ................................................................................................................................................. 86
55. 110.16-SE2157: Engine Coolant Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 87
56. 110.4-SE76: Engine Coolant Temperature 1 Sensor Circuit - Voltage Below Normal or Shorted to
Low Source .................................................................................................................................................. 88
57. 110.0-SE81: Engine Coolant Temperature - Data Valid But Above Normal Operating Range - Most
Severe Level ................................................................................................................................................ 89
58. 110.2-SE3668: Engine Coolant Temperature - Data Erratic, Intermittent, or Incorrect ................. 90
59. 110.2-SE3669: Engine Coolant Temperature - Data Erratic, Intermittent, or Incorrect ................. 91
60. 110.2-SE3805: Engine Coolant Temperature - Data Erratic, Intermittent, or Incorrect ................. 92
61. 101.15-SE2018: Crankcase Pressure - Data Valid But Above Normal Operating Range - Least
Severe Level ................................................................................................................................................ 93
62. 101.16-SE2020: Crankcase Pressure - Data Valid But Above Normal Operating Range -
Moderately Severe Level ............................................................................................................................ 94

Cummins Inc. Revision Date: March 30, 2017 3


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

63. 101.3-SE1422: Crankcase Pressure Circuit - Voltage Above Normal or Shorted to High Source ... 95
64. 101.4-SE1424: Crankcase Pressure Circuit - Voltage Below Normal or Shorted to Low Source .... 96
65. 1323.31-SE2344: Engine Misfire Cylinder 1 - Condition Exists ....................................................... 97
66. 1324.31-SE2346: Engine Misfire Cylinder 2 - Condition Exists ....................................................... 99
67. 1325.31-SE2347: Engine Misfire Cylinder 3 - Condition Exists ..................................................... 101
68. 1326.31-SE2345: Engine Misfire Cylinder 4 - Condition Exists ..................................................... 103
69. 1327.31-SE2348: Engine Misfire Cylinder 5 - Condition Exists ..................................................... 105
70. 1328.31-SE2349: Engine Misfire Cylinder 6 - Condition Exists ..................................................... 107
71. 3242.16-SE3070: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 109
72. 4765.2-SE13176: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 110
73. 4765.2-SE2858: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 112
74. 4765.2-SE13173: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 114
75. 4765.16-SE3068: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 115
76. 5298.18-SE4719: Aftertreatment 1 Diesel Oxidation Catalyst Conversion Efficiency - Data Valid
But Below Normal Operating Range - Moderately Severe Level .............................................................. 116
77. 4796.31-SE1757: Aftertreatment 1 Diesel Oxidation Catalyst Missing - Condition Exists............ 118
78. 3242.2-SE13177: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 120
79. 3242.2-SE2844: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 122
80. 3242.2-SE13174: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 124
81. 3242.16-SE3069: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 125
82. 3242.15-SE1759: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But
Above Normal Operating Range - Least Severe Level .............................................................................. 126
83. 3242.0-SE3591: Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But
Above Normal Operating Range - Most Severe Level............................................................................... 127
84. 3750.31-SE7455: Aftertreatment Diesel Particulate Filter 1 Conditions Not Met for Active
Regeneration - Condition Exists ................................................................................................................ 128
85. 3251.10-SE2851: Aftertreatment 1 Diesel Particulate Filter Differential Pressure - Abnormal Rate
of Change .................................................................................................................................................. 129

Cummins Inc. Revision Date: March 30, 2017 4


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

86. 3936.15-SE2085: Aftertreatment 1 Diesel Particulate Filter System - Data Valid But Above Normal
Operating Range - Least Severe Level ....................................................................................................... 130
87. 3251.2-SE7316: Aftertreatment Diesel Particulate Filter Differential Pressure - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 132
88. 3251.3-SE2849: Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 133
89. 3251.4-SE2857: Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit -
Voltage Below Normal or Shorted to Low Source .................................................................................... 134
90. 3246.16-SE3072: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 135
91. 5319.31-SE3036: Aftertreatment Diesel Particulate Filter Incomplete Regeneration - Condition
Exists ...................................................................................................................................................... 136
92. 4795.31-SE1752: Aftertreatment 1 Diesel Particulate Filter Missing - Condition Exists .............. 138
93. 3610.10-SE2983: Aftertreatment 1 Diesel Particulate Filter Outlet Pressure - Abnormal Rate of
Change ...................................................................................................................................................... 139
94. 3610.20-SE3284: Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor - Data Not
Rational - Drifted High .............................................................................................................................. 140
95. 3610.2-SE7317: Aftertreatment 1 Diesel Particulate Filter Outlet Pressure - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 141
96. 3610.3-SE2882: Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit - Voltage
Above Normal or Shorted to High Source ................................................................................................ 142
97. 3610.4-SE2883: Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 143
98. 3246.21-SE13178: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor - Data
Not Rational - Drifted Low ........................................................................................................................ 144
99. 3246.2-SE2852: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 146
100. 3246.2-SE13175: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 148
101. 3246.16-SE3071: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 149
102. 3246.15-SE1754: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Valid But
Above Normal Operating Range - Least Severe Level .............................................................................. 150
103. 3936.2-SE13050: Aftertreatment 1 Diesel Particulate Filter System - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 151
104. 3246.0-SE3592: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Valid But
Above Normal Operating Range - Most Severe Level............................................................................... 154

Cummins Inc. Revision Date: March 30, 2017 5


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

105. 3251.16-SE1887: Aftertreatment Diesel Particulate Filter Differential Pressure - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 155
106. 3251.15-SE2096: Aftertreatment Diesel Particulate Filter Differential Pressure - Data Valid But
Above Normal Operating Range - Least Severe Level .............................................................................. 156
107. 3251.0-SE2097: Aftertreatment Diesel Particulate Filter Differential Pressure - Data Valid But
Above Normal Operating Range - Most Severe Level............................................................................... 157
108. 5397.31-SE3590: Aftertreatment Diesel Particulate Filter Regeneration too Frequent - Condition
Exists ...................................................................................................................................................... 158
109. 91.2-SE1380: Accelerator Pedal or Lever Position Sensor 1 - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 162
110. 91.8-SE6991: Accelerator Pedal or Lever Position Sensor 1 Circuit Frequency - Abnormal
Frequency or Pulse Width or Period ......................................................................................................... 163
111. 91.8-SE6990: Accelerator Pedal or Lever Position Sensor 1 Circuit Frequency - Abnormal
Frequency or Pulse Width or Period ......................................................................................................... 164
112. 2623.8-SE6993: Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency - Abnormal
Frequency or Pulse Width or Period ......................................................................................................... 165
113. 2623.8-SE6992: Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency - Abnormal
Frequency or Pulse Width or Period ......................................................................................................... 166
114. 629.12-SE216: Engine Control Module Critical Internal Failure - Bad Intelligent Device or
Component ............................................................................................................................................... 167
115. 411.3-SE485: Exhaust Gas Recirculation Differential Pressure Sensor Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 168
116. 411.4-SE483: Exhaust Gas Recirculation Differential Pressure Sensor Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 169
117. 411.2-SE1911: Exhaust Gas Recirculation Differential Pressure - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 170
118. 2791.3-SE2797: EGR Valve Control Circuit - Voltage Above Normal or Shorted to High Source . 171
119. 2791.4-SE2798: EGR Valve Control Circuit - Voltage Below Normal or Shorted to Low Source .. 172
120. 2791.3-SE3582: EGR Valve Control Circuit - Voltage Above Normal or Shorted to High Source . 173
121. 27.2-SE3866: EGR Valve Position - Data Erratic, Intermittent, or Incorrect ................................. 174
122. 27.2-SE3867: EGR Valve Position - Data Erratic, Intermittent, or Incorrect ................................. 175
123. 27.3-SE3202: EGR Valve Position Circuit - Voltage Above Normal or Shorted to High Source .... 176
124. 27.4-SE3203: EGR Valve Position Circuit - Voltage Below Normal or Shorted to Low Source ..... 177
125. 2791.13-SE3980: EGR Valve Controller - Out of Calibration ......................................................... 178
126. 412.2-SE3876: Exhaust Gas Recirculation Temperature - Data Erratic, Intermittent, or Incorrect....
...................................................................................................................................................... 179

Cummins Inc. Revision Date: March 30, 2017 6


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

127. 412.2-SE3877: Exhaust Gas Recirculation Temperature - Data Erratic, Intermittent, or Incorrect....
...................................................................................................................................................... 180
128. 412.2-SE3878: Exhaust Gas Recirculation Temperature - Data Erratic, Intermittent, or Incorrect....
...................................................................................................................................................... 181
129. 412.2-SE3872: Exhaust Gas Recirculation Temperature - Data Erratic, Intermittent, or Incorrect....
...................................................................................................................................................... 182
130. 412.3-SE496: Exhaust Gas Recirculation Temperature Sensor Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 183
131. 412.4-SE495: Exhaust Gas Recirculation Temperature Sensor Circuit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 184
132. 412.16-SE869: Exhaust Gas Recirculation Temperature - Data Valid But Above Normal Operating
Range - Moderately Severe Level ............................................................................................................. 185
133. 412.15-SE870: Exhaust Gas Recirculation Temperature - Data Valid But Above Normal Operating
Range - Least Severe Level ........................................................................................................................ 186
134. 3058.16-SE7295: Engine Exhaust Gas Recirculation (EGR) System - Data Valid But Above Normal
Operating Range - Moderately Severe Level ............................................................................................ 187
135. 3058.18-SE7296: Engine Exhaust Gas Recirculation (EGR) System - Data Valid But Below Normal
Operating Range - Moderately Severe Level ............................................................................................ 188
136. 3058.10-SE12125: Engine Exhaust Gas Recirculation (EGR) System - Abnormal Rate of Change 189
137. 4765.3-SE6729: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 190
138. 4765.4-SE6730: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature Sensor Circuit -
Voltage Below Normal or Shorted to Low Source .................................................................................... 191
139. 3242.3-SE6731: Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 192
140. 3242.4-SE6732: Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit -
Voltage Below Normal or Shorted to Low Source .................................................................................... 193
141. 3246.3-SE6733: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 194
142. 3246.4-SE6734: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit -
Voltage Below Normal or Shorted to Low Source .................................................................................... 195
143. 5742.12-SE6722: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 196
144. 5742.12-SE6724: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 197
145. 5742.12-SE6721: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 198

Cummins Inc. Revision Date: March 30, 2017 7


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

146. 5742.12-SE6726: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 199
147. 5742.3-SE6727: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Voltage
Above Normal or Shorted to High Source ................................................................................................ 200
148. 5742.4-SE6728: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 201
149. 5742.16-SE7167: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Data
Valid But Above Normal Operating Range - Moderately Severe Level..................................................... 202
150. 5742.12-SE6725: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 203
151. 5742.11-SE7168: Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Root
Cause Not Known ...................................................................................................................................... 204
152. 4765.3-SE6735: Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 205
153. 3242.3-SE6736: Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 206
154. 3246.3-SE6737: Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit -
Voltage Above Normal or Shorted to High Source ................................................................................... 207
155. 4363.3-SE6762: Aftertreatment 1 SCR Outlet Temperature Sensor Circuit - Voltage Above Normal
or Shorted to High Source......................................................................................................................... 208
156. 4363.4-SE6763: Aftertreatment 1 SCR Outlet Temperature Sensor Circuit - Voltage Below Normal
or Shorted to Low Source ......................................................................................................................... 209
157. 5743.12-SE6765: Aftertreatment Selective Catalytic Reduction Temperature Sensor Module - Bad
Intelligent Device or Component .............................................................................................................. 210
158. 111.18-SE657: Coolant Level - Data Valid But Below Normal Operating Range - Moderately
Severe Level .............................................................................................................................................. 211
159. 190.0-SE124: Engine Crankshaft Speed/Position - Data Valid But Above Normal Operating Range -
Most Severe Level ..................................................................................................................................... 212
160. 3222.5-SE5151: Aftertreatment Intake Gas Sensor Heater - Current Below Normal or Open Circuit
...................................................................................................................................................... 213
161. 5024.10-SE5246: Aftertreatment 1 Intake NOx Sensor Heater - Abnormal Rate of Change ....... 216
162. 5024.10-SE5245: Aftertreatment 1 Intake NOx Sensor Heater - Abnormal Rate of Change ....... 218
163. 3218.2-SE5829: Aftertreatment 1 Intake NOx Sensor Power Supply - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 219
164. 3218.2-SE5152: Aftertreatment 1 Intake NOx Sensor Power Supply - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 220
165. 3216.4-SE5153: Aftertreatment 1 Intake NOx Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 221

Cummins Inc. Revision Date: March 30, 2017 8


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

166. 3216.4-SE7986: Aftertreatment 1 Intake NOx Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 225
167. 723.2-SE422: Engine Camshaft Speed/Position Sensor - Data Erratic, Intermittent, or Incorrect229
168. 723.2-SE415: Engine Camshaft Speed/Position Sensor - Data Erratic, Intermittent, or Incorrect230
169. 723.2-SE45: Engine Camshaft Speed/Position Sensor - Data Erratic, Intermittent, or Incorrect . 231
170. 190.11-SE460: Engine Speed - Root Cause Not Known ................................................................ 232
171. 190.2-SE419: Engine Crankshaft Speed/Position - Data Erratic, Intermittent, or Incorrect......... 233
172. 190.2-SE417: Engine Crankshaft Speed/Position - Data Erratic, Intermittent, or Incorrect......... 234
173. 190.2-SE54: Engine Crankshaft Speed/Position - Data Erratic, Intermittent, or Incorrect ........... 235
174. 636.8-SE12594: Engine Position Sensor - Abnormal Frequency or Pulse Width or Period .......... 236
175. 723.7-SE389: Engine Speed/Position Camshaft and Crankshaft Misalignment - Mechanical System
Not Responding or Out of Adjustment ..................................................................................................... 237
176. 5357.31-SE8483: Engine Fuel Injection Quantity Error for Multiple Cylinders - Condition Exists 238
177. 1209.2-SE3924: Exhaust Gas Pressure 1 - Data Erratic, Intermittent, or Incorrect ...................... 240
178. 1209.2-SE3922: Exhaust Gas Pressure 1 - Data Erratic, Intermittent, or Incorrect ...................... 241
179. 1209.2-SE4442: Exhaust Gas Pressure 1 - Data Erratic, Intermittent, or Incorrect ...................... 242
180. 1209.3-SE493: Exhaust Gas Pressure Sensor 1 Circuit - Voltage Above Normal or Shorted to High
Source ...................................................................................................................................................... 243
181. 1209.4-SE494: Exhaust Gas Pressure Sensor 1 Circuit - Voltage Below Normal or Shorted to Low
Source ...................................................................................................................................................... 244
182. 647.4-SE1003: Fan Control Circuit - Voltage Below Normal or Shorted to Low Source ............... 245
183. 647.3-SE1004: Fan Control Circuit - Voltage Above Normal or Shorted to High Source .............. 246
184. 96.3-SE3946: Fuel Level (Main Tank) Sensor Circuit - Voltage Above Normal or Shorted to High
Source ...................................................................................................................................................... 247
185. 96.4-SE3947: Fuel Level (Main Tank) Sensor Circuit - Voltage Below Normal or Shorted to Low
Source ...................................................................................................................................................... 248
186. 157.7-SE7212: Injector Metering Rail 1 Pressure - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 249
187. 5585.18-SE8369: Engine Injector Metering Rail 1 Cranking Pressure - Data Valid But Below
Normal Operating Range - Moderately Severe Level ............................................................................... 250
188. 157.7-SE7209: Injector Metering Rail 1 Pressure - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 251
189. 157.7-SE7211: Injector Metering Rail 1 Pressure - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 253
190. 729.3-SE665: Engine Intake Air Heater 1 Circuit - Voltage Above Normal or Shorted to High
Source ...................................................................................................................................................... 255

Cummins Inc. Revision Date: March 30, 2017 9


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

191. 729.4-SE668: Engine Intake Air Heater 1 Circuit - Voltage Below Normal or Shorted to Low Source
...................................................................................................................................................... 256
192. 110.31-SE2141: Engine Coolant Temperature - Condition Exists ................................................. 257
193. 3464.3-SE12370: Electronic Throttle Control Actuator Driver Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 258
194. 3464.4-SE12371: Electronic Throttle Control Actuator Driver Circuit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 259
195. 3464.3-SE12372: Electronic Throttle Control Actuator Driver Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 260
196. 51.2-SE4014: Engine Intake Throttle Actuator Position Sensor - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 261
197. 51.2-SE4015: Engine Intake Throttle Actuator Position Sensor - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 262
198. 51.3-SE3530: Engine Intake Throttle Actuator Position Sensor Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 263
199. 51.4-SE3529: Engine Intake Throttle Actuator Position Sensor Circuit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 264
200. 5395.18-SE3783: Engine Idle Fuel Quantity - Data Valid But Below Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 265
201. 188.16-SE3775: Engine Speed At Idle - Data Valid But Above Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 267
202. 188.18-SE3781: Engine Speed At Idle - Data Valid But Below Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 269
203. 105.16-SE649: Intake Manifold 1 Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 271
204. 105.15-SE648: Intake Manifold 1 Temperature - Data Valid But Above Normal Operating Range -
Least Severe Level ..................................................................................................................................... 272
205. 5246.16-SE5737: Aftertreatment SCR Operator Inducement Severity - Data Valid But Above
Normal Operating Range - Moderately Severe Level ............................................................................... 273
206. 1569.15-SE5408: Engine Protection Torque Derate - Data Valid But Above Normal Operating
Range - Least Severe Level ........................................................................................................................ 274
207. 3695.2-SE6976: Aftertreatment Regeneration Inhibit Switch - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 275
208. 3703.31-SE5571: Aftertreatment Regeneration Inhibited Due to Inhibit Switch - Condition Exists ..
...................................................................................................................................................... 276
209. 729.5-SE7368: Engine Intake Air Heater 1 Circuit - Current Below Normal or Open Circuit ........ 277
210. 1267.4-SE997: Idle Shutdown Vehicle Accessories Relay Driver Circuit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 278

Cummins Inc. Revision Date: March 30, 2017 10


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

211. 1267.3-SE998: Idle Shutdown Vehicle Accessories Relay Driver Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 279
212. 651.5-SE916: Injector Solenoid Driver Cylinder 1 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 280
213. 652.5-SE917: Injector Solenoid Driver Cylinder 2 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 281
214. 653.5-SE918: Injector Solenoid Driver Cylinder 3 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 282
215. 654.5-SE919: Injector Solenoid Driver Cylinder 4 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 283
216. 655.5-SE920: Injector Solenoid Driver Cylinder 5 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 284
217. 656.5-SE921: Injector Solenoid Driver Cylinder 6 Circuit - Current Below Normal or Open Circuit ...
...................................................................................................................................................... 285
218. 639.9-SE1848: SAE J1939 Datalink - Abnormal Update Rate........................................................ 286
219. 639.13-SE747: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 287
220. 639.9-SE718: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 288
221. 91.13-SE748: SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System - Out of
Calibration ................................................................................................................................................. 289
222. 91.9-SE712: SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System - Abnormal Update
Rate ...................................................................................................................................................... 290
223. 1590.2-SE7559: Adaptive Cruise Control Mode - Data Erratic, Intermittent, or Incorrect........... 291
224. 639.13-SE749: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 292
225. 639.9-SE714: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 293
226. 1590.2-SE1792: Adaptive Cruise Control Mode - Data Erratic, Intermittent, or Incorrect........... 294
227. 91.13-SE750: SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System - Out of
Calibration ................................................................................................................................................. 295
228. 558.19-SE5333: Accelerator Pedal or Lever Idle Validation Switch - Received Network Data in
Error ...................................................................................................................................................... 296
229. 558.9-SE709: Accelerator Pedal or Lever Idle Validation Switch - Abnormal Update Rate .......... 297
230. 5742.9-SE12509: Aftertreatment Diesel Particulate Filter Temperature Sensor Module -
Abnormal Update Rate ............................................................................................................................. 298
231. 5742.9-SE12508: Aftertreatment Diesel Particulate Filter Temperature Sensor Module -
Abnormal Update Rate ............................................................................................................................. 299
232. 3216.9-SE2487: Aftertreatment 1 Intake NOx Sensor - Abnormal Update Rate .......................... 300
233. 3226.9-SE2488: Aftertreatment 1 Outlet NOx Sensor - Abnormal Update Rate.......................... 301

Cummins Inc. Revision Date: March 30, 2017 11


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

234. 639.13-SE751: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 302
235. 639.9-SE716: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 303
236. 5605.31-SE6017: Cruise Control Pause Command - Condition Exists .......................................... 304
237. 5603.9-SE5825: Cruise Control Disable Command - Abnormal Update Rate ............................... 305
238. 5603.31-SE5995: Cruise Control Disable Command - Condition Exists ........................................ 306
239. 5603.9-SE5996: Cruise Control Disable Command - Abnormal Update Rate ............................... 307
240. 639.13-SE752: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 308
241. 639.9-SE698: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 309
242. 639.9-SE5158: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................. 310
243. 5603.9-SE5999: Cruise Control Disable Command - Abnormal Update Rate ............................... 311
244. 639.13-SE753: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 312
245. 639.9-SE702: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 313
246. 5603.9-SE6000: Cruise Control Disable Command - Abnormal Update Rate ............................... 314
247. 639.13-SE754: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 315
248. 639.9-SE701: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 316
249. 639.13-SE755: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 317
250. 639.9-SE700: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 318
251. 1761.13-SE8568: Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor - Out of Calibration 319
252. 1761.9-SE7665: Aftertreatment 1 Diesel Exhaust Fluid Tank Level - Abnormal Update Rate...... 320
253. 3031.13-SE8567: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor - Out of
Calibration ................................................................................................................................................. 321
254. 3031.9-SE7666: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature - Abnormal Update
Rate ...................................................................................................................................................... 322
255. 1081.9-SE5305: Engine Wait to Start Lamp - Abnormal Update Rate .......................................... 323
256. 639.13-SE7710: SAE J1939 Multiplexing Configuration Error - Out of Calibration ....................... 324
257. 1081.31-SE7712: Engine Wait to Start Lamp - Condition Exists ................................................... 325
258. 1081.19-SE7711: Engine Wait to Start Lamp - Received Network Data in Error .......................... 326
259. 6806.31-SE12824: ECM 1 Data Link Interface Mismatch - Condition Exists ................................. 327
260. 563.31-SE7014: Anti-Lock Braking (ABS) Active - Condition Exists ............................................... 328
261. 563.9-SE7013: Anti-Lock Braking (ABS) Controller - Abnormal Update Rate ............................... 329
262. 639.13-SE757: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 330
263. 639.9-SE704: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 331
264. 96.13-SE7607: Fuel Level 1 - Out of Calibration ........................................................................... 332
265. 96.9-SE7606: Fuel Level 1 - Abnormal Update Rate ..................................................................... 333

Cummins Inc. Revision Date: March 30, 2017 12


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

266. 38.13-SE8019: Fuel Level 2 - Out of Calibration ........................................................................... 334


267. 38.9-SE8020: Fuel Level 2 - Abnormal Update Rate ..................................................................... 335
268. 639.13-SE758: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 336
269. 639.9-SE694: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 337
270. 639.13-SE759: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 338
271. 639.9-SE686: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 339
272. 91.19-SE1001: SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System - Received
Network Data in Error ............................................................................................................................... 340
273. 974.19-SE1002: SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Sensor System -
Received Network Data in Error ............................................................................................................... 341
274. 191.19-SE5109: Transmission Output Shaft Speed - Received Network Data in Error ................ 342
275. 191.9-SE5110: Transmission Output Shaft Speed - Abnormal Update Rate ................................ 343
276. 639.13-SE760: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 344
277. 639.9-SE697: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 345
278. 639.9-SE710: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 346
279. 639.9-SE711: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 347
280. 639.13-SE763: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 348
281. 639.9-SE706: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 349
282. 639.13-SE764: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 350
283. 639.9-SE707: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 351
284. 639.13-SE765: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 352
285. 639.9-SE708: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 353
286. 639.13-SE766: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 354
287. 639.9-SE705: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 355
288. 639.13-SE2108: SAE J1939 Multiplexing Configuration Error - Out of Calibration ....................... 356
289. 639.9-SE2109: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................. 357
290. 639.13-SE2110: SAE J1939 Multiplexing Configuration Error - Out of Calibration ....................... 358
291. 639.9-SE2111: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................. 359
292. 639.13-SE767: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 360
293. 639.9-SE695: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 361
294. 639.13-SE769: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 362
295. 639.13-SE768: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 363
296. 639.9-SE715: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 364
297. 639.9-SE713: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 365

Cummins Inc. Revision Date: March 30, 2017 13


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

298. 639.13-SE5188: SAE J1939 Multiplexing Configuration Error - Out of Calibration ....................... 366
299. 639.9-SE5187: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................. 367
300. 639.13-SE770: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 368
301. 639.9-SE696: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 369
302. 639.13-SE771: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 370
303. 639.9-SE719: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 371
304. 639.13-SE773: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 372
305. 639.9-SE699: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 373
306. 1623.9-SE5307: Tachograph Output Shaft Speed - Abnormal Update Rate ................................ 374
307. 639.13-SE746: SAE J1939 Multiplexing Configuration Error - Out of Calibration ......................... 375
308. 639.9-SE703: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 376
309. 639.9-SE717: SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate ................... 377
310. 3364.13-SE8569: Aftertreatment Diesel Exhaust Fluid Quality - Out of Calibration .................... 378
311. 3364.9-SE6447: Aftertreatment Diesel Exhaust Fluid Quality - Abnormal Update Rate .............. 379
312. 1818.31-SE4354: Roll Over Protection Brake Control Active - Condition Exists ........................... 380
313. 563.9-SE3606: Anti-Lock Braking (ABS) Controller - Abnormal Update Rate ............................... 381
314. 641.9-SE8054: VGT Actuator Driver Circuit - Abnormal Update Rate .......................................... 382
315. 84.19-SE5111: Wheel-Based Vehicle Speed - Received Network Data in Error ........................... 383
316. 84.9-SE5112: Wheel-Based Vehicle Speed - Abnormal Update Rate ........................................... 384
317. 1378.31-SE1904: Engine Oil Change Interval - Condition Exists ................................................... 385
318. 3597.12-SE421: Injector Power Supply - Bad Intelligent Device or Component .......................... 386
319. 102.16-SE7293: Intake Manifold 1 Pressure - Data Valid But Above Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 387
320. 102.18-SE7294: Intake Manifold 1 Pressure - Data Valid But Below Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 388
321. 102.10-SE12124: Intake Manifold 1 Pressure - Abnormal Rate of Change .................................. 389
322. 1322.31-SE2350: Engine Misfire for Multiple Cylinders - Condition Exists .................................. 390
323. 91.2-SE3200: Accelerator Pedal or Lever Position Sensor 1 - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 392
324. 3216.2-SE5369: Aftertreatment 1 Intake NOx - Data Erratic, Intermittent, or Incorrect ............. 393
325. 3216.20-SE5365: Aftertreatment 1 Intake NOx Sensor - Data Not Rational - Drifted High ......... 394
326. 3216.21-SE5366: Aftertreatment 1 Intake NOx Sensor - Data Not Rational - Drifted Low .......... 395
327. 3216.10-SE5569: Aftertreatment 1 Intake NOx Sensor - Abnormal Rate of Change ................... 396

Cummins Inc. Revision Date: March 30, 2017 14


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

328. 3226.4-SE5990: Aftertreatment 1 Outlet NOx Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 397
329. 5031.10-SE5051: Aftertreatment 1 Outlet NOx Sensor Heater - Abnormal Rate of Change ....... 400
330. 3226.20-SE5976: Aftertreatment 1 Outlet NOx Sensor - Data Not Rational - Drifted High ......... 401
331. 3226.21-SE5978: Aftertreatment 1 Outlet NOx Sensor - Data Not Rational - Drifted Low .......... 403
332. 3226.4-SE11104: Aftertreatment 1 Outlet NOx Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 405
333. 3226.10-SE5989: Aftertreatment 1 Outlet NOx Sensor - Abnormal Rate of Change ................... 409
334. 3228.2-SE5988: Aftertreatment 1 Outlet NOx Sensor Power Supply - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 411
335. 3228.2-SE6021: Aftertreatment 1 Outlet NOx Sensor Power Supply - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 412
336. 3226.4-SE5987: Aftertreatment 1 Outlet NOx Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 413
337. 3226.11-SE11496: Aftertreatment 1 Outlet NOx Sensor - Root Cause Not Known ..................... 417
338. 3226.2-SE7613: Aftertreatment 1 Outlet NOx Sensor - Data Erratic, Intermittent, or Incorrect . 419
339. 251.10-SE4760: Real Time Clock - Abnormal Rate of Change ...................................................... 421
340. 251.10-SE4759: Real Time Clock - Abnormal Rate of Change ...................................................... 422
341. 100.18-SE74: Engine Oil Rifle Pressure - Data Valid But Below Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 423
342. 100.1-SE279: Engine Oil Rifle Pressure - Data Valid But Below Normal Operating Range - Most
Severe Level .............................................................................................................................................. 424
343. 100.2-SE687: Engine Oil Rifle Pressure - Data Erratic, Intermittent, or Incorrect ........................ 425
344. 629.12-SE5344: Engine Control Module Critical Internal Failure - Bad Intelligent Device or
Component ............................................................................................................................................... 426
345. 3597.2-SE294: Power Supply Lost With Ignition On - Data Erratic, Intermittent, or Incorrect .... 427
346. 5298.17-SE3545: Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency - Data Valid But
Below Normal Operating Range - Least Severe Level ............................................................................... 428
347. 5835.9-SE12781: Aftertreatment 1 Particulate Sensor - Abnormal Update Rate ........................ 430
348. 5835.9-SE12782: Aftertreatment 1 Particulate Sensor - Abnormal Update Rate ........................ 431
349. 5835.9-SE12783: Aftertreatment 1 Particulate Sensor - Abnormal Update Rate ........................ 432
350. 5835.9-SE12784: Aftertreatment 1 Particulate Sensor - Abnormal Update Rate ........................ 433
351. 5835.9-SE12785: Aftertreatment 1 Particulate Sensor - Abnormal Update Rate ........................ 434
352. 7854.12-SE13133: Aftertreatment 1 Diesel Particulate Filter Soot Sensor Module Voltage
Converter - Bad Intelligent Device or Component.................................................................................... 435

Cummins Inc. Revision Date: March 30, 2017 15


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

353. 6778.16-SE12924: Aftertreatment 1 Particulate Sensor Power Supply - Data Valid But Above
Normal Operating Range - Moderately Severe Level ............................................................................... 437
354. 6778.3-SE12920: Aftertreatment 1 Particulate Sensor Power Supply - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 439
355. 6778.4-SE12921: Aftertreatment 1 Particulate Sensor Power Supply - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 441
356. 7329.2-SE12922: Aftertreatment 1 Particulate Sensor Heater Power Supply - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 443
357. 7329.2-SE12923: Aftertreatment 1 Particulate Sensor Heater Power Supply - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 445
358. 7321.3-SE12914: Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit - Voltage
Above Normal or Shorted to High Source ................................................................................................ 448
359. 7321.4-SE12915: Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 450
360. 7323.4-SE12916: Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 452
361. 7321.4-SE12917: Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 454
362. 5835.21-SE13109: Aftertreatment 1 Particulate Sensor - Data Not Rational - Drifted Low......... 456
363. 5835.3-SE12918: Aftertreatment 1 Particulate Sensor Circuit - Voltage Above Normal or Shorted
to High Source ........................................................................................................................................... 459
364. 5835.4-SE12919: Aftertreatment 1 Particulate Sensor Circuit - Voltage Below Normal or Shorted
to Low Source ........................................................................................................................................... 461
365. 6777.10-SE12950: Aftertreatment 1 Particulate Sensor Detection Status - Abnormal Rate of
Change ...................................................................................................................................................... 464
366. 7854.2-SE13054: Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply - Data
Erratic, Intermittent, or Incorrect ............................................................................................................. 467
367. 6773.7-SE13070: Aftertreatment 1 Particulate Sensor Regeneration Status - Mechanical System
Not Responding or Out of Adjustment ..................................................................................................... 468
368. 6773.16-SE13097: Aftertreatment 1 Particulate Sensor Regeneration Status - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 470
369. 5569.2-SE12963: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature - Data Erratic, Intermittent, or Incorrect ............................................................................ 473
370. 5569.3-SE12945: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature 1 Circuit - Voltage Above Normal or Shorted to High Source............................................. 475
371. 5569.4-SE12944: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature 1 Circuit - Voltage Below Normal or Shorted to Low Source.............................................. 477

Cummins Inc. Revision Date: March 30, 2017 16


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

372. 5569.3-SE12947: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature 2 Circuit - Voltage Above Normal or Shorted to High Source............................................. 479
373. 5569.4-SE12946: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature 2 Circuit - Voltage Below Normal or Shorted to Low Source.............................................. 481
374. 5569.16-SE13115: Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal
Temperature - Data Valid But Above Normal Operating Range - Moderately Severe Level .................... 483
375. 6780.2-SE13096: Aftertreatment 1 Diesel Particulate Filter Soot Temperature Sensor - Data
Erratic, Intermittent, or Incorrect ............................................................................................................. 485
376. 6780.2-SE13095: Aftertreatment 1 Diesel Particulate Filter Soot Temperature Sensor - Data
Erratic, Intermittent, or Incorrect ............................................................................................................. 487
377. 6780.3-SE12948: Aftertreatment 1 Diesel Particulate Filter Soot Temperature Sensor - Voltage
Above Normal or Shorted to High Source ................................................................................................ 489
378. 6780.4-SE12949: Aftertreatment 1 Diesel Particulate Filter Soot Temperature Sensor - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 491
379. 7854.3-SE13048: Aftertreatment 1 Diesel Particulate Filter Soot Sensor Module - Voltage Above
Normal or Shorted to High Source............................................................................................................ 493
380. 7854.4-SE13049: Aftertreatment 1 Diesel Particulate Filter Soot Sensor Module - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 494
381. 7854.6-SE13051: Aftertreatment 1 Diesel Particulate Filter Soot Sensor Module - Current Above
Normal or Grounded Circuit ..................................................................................................................... 495
382. 629.12-SE217: Engine Control Module Warning Internal Hardware Failure - Bad Intelligent Device
or Component ........................................................................................................................................... 497
383. 4375.2-SE12526: Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 498
384. 651.7-SE3104: Injector Solenoid Driver Cylinder 1 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 499
385. 652.7-SE3105: Injector Solenoid Driver Cylinder 2 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 501
386. 653.7-SE3102: Injector Solenoid Driver Cylinder 3 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 503
387. 654.7-SE3106: Injector Solenoid Driver Cylinder 4 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 505
388. 655.7-SE3107: Injector Solenoid Driver Cylinder 5 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 507
389. 656.7-SE3108: Injector Solenoid Driver Cylinder 6 - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 509
390. 629.12-SE33: Engine Control Module Critical Internal Failure - Bad Intelligent Device or
Component ............................................................................................................................................... 511

Cummins Inc. Revision Date: March 30, 2017 17


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

391. 630.12-SE5340: Engine Control Module Calibration Memory - Bad Intelligent Device or
Component ............................................................................................................................................... 512
392. 4331.16-SE12528: Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity - Data Valid But
Above Normal Operating Range - Moderately Severe Level .................................................................... 513
393. 4331.18-SE12527: Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity - Data Valid But
Below Normal Operating Range - Moderately Severe Level .................................................................... 514
394. 974.3-SE1367: Remote Accelerator Pedal or Lever Position Sensor 1 Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 515
395. 974.4-SE1368: Remote Accelerator Pedal or Lever Position Sensor 1 Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 516
396. 91.3-SE63: Accelerator Pedal or Lever Position Sensor 1 Circuit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 517
397. 91.4-SE64: Accelerator Pedal or Lever Position Sensor 1 Circuit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 518
398. 4363.0-SE2889: Aftertreatment 1 SCR Outlet Temperature - Data Valid But Above Normal
Operating Range - Most Severe Level ....................................................................................................... 519
399. 4794.31-SE10102: Aftertreatment 1 SCR Catalyst System Missing - Condition Exists ................. 521
400. 4339.7-SE10852: Aftertreatment 1 SCR Feedback Control Status - Mechanical System Not
Responding or Out of Adjustment ............................................................................................................ 526
401. 4364.31-SE10910: Aftertreatment 1 SCR Conversion Efficiency - Condition Exists ..................... 530
402. 3217.20-SE12895: Aftertreatment Intake Oxygen Sensor - Data Not Rational - Drifted High ..... 536
403. 3217.21-SE12900: Aftertreatment Intake Oxygen Sensor - Data Not Rational - Drifted Low ...... 539
404. 5862.2-SE2895: Aftertreatment 1 SCR Intermediate Gas Temperature Sensor - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 542
405. 5862.14-SE7288: Aftertreatment 1 SCR Intermediate Gas Temperature - Special Instructions .. 544
406. 3227.20-SE12580: Aftertreatment Outlet Oxygen - Data Not Rational - Drifted High ................. 545
407. 3227.21-SE12581: Aftertreatment Outlet Oxygen - Data Not Rational - Drifted Low.................. 547
408. 4363.2-SE3785: Aftertreatment 1 SCR Outlet Temperature Sensor - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 549
409. 4363.2-SE13180: Aftertreatment 1 SCR Outlet Temperature Sensor - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 551
410. 5031.10-SE5982: Aftertreatment 1 Outlet NOx Sensor Heater - Abnormal Rate of Change ....... 552
411. 4363.16-SE5295: Aftertreatment 1 SCR Outlet Temperature - Data Valid But Above Normal
Operating Range - Moderately Severe Level ............................................................................................ 553
412. 4363.0-SE5293: Aftertreatment 1 SCR Outlet Temperature - Data Valid But Above Normal
Operating Range - Most Severe Level ....................................................................................................... 554
413. 3509.3-SE243: Sensor Supply 1 Circuit - Voltage Above Normal or Shorted to High Source ....... 555

Cummins Inc. Revision Date: March 30, 2017 18


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

414. 3509.4-SE225: Sensor Supply 1 Circuit - Voltage Below Normal or Shorted to Low Source ........ 556
415. 3510.3-SE119: Sensor Supply 2 Circuit - Voltage Above Normal or Shorted to High Source ....... 557
416. 3510.4-SE101: Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source ........ 558
417. 3511.3-SE814: Sensor Supply 3 Circuit - Voltage Above Normal or Shorted to High Source ....... 559
418. 3511.4-SE816: Sensor Supply 3 Circuit - Voltage Below Normal or Shorted to Low Source ........ 560
419. 3512.3-SE817: Sensor Supply 4 Circuit - Voltage Above Normal or Shorted to High Source ....... 561
420. 3512.4-SE815: Sensor Supply 4 Circuit - Voltage Below Normal or Shorted to Low Source ........ 562
421. 3513.3-SE1893: Sensor Supply 5 Circuit - Voltage Above Normal or Shorted to High Source ..... 563
422. 3513.4-SE1894: Sensor Supply 5 Circuit - Voltage Below Normal or Shorted to Low Source ...... 564
423. 3514.3-SE2030: Sensor Supply 6 Circuit - Voltage Above Normal or Shorted to High Source ..... 565
424. 3514.4-SE2031: Sensor Supply 6 Circuit - Voltage Below Normal or Shorted to Low Source ...... 566
425. 521.2-SE8109: Brake Pedal Position - Data Erratic, Intermittent, or Incorrect ............................ 567
426. 6304.31-SE7827: Brake Switch and Accelerator Pedal Position Incompatible - Condition Exists 568
427. 5246.0-SE5496: Aftertreatment SCR Operator Inducement - Data Valid But Above Normal
Operating Range - Most Severe Level ....................................................................................................... 569
428. 1675.31-SE5497: Engine Starter Mode Overcrank Protection - Condition Exists......................... 570
429. 677.4-SE323: Engine Starter Motor Relay Circuit - Voltage Below Normal or Shorted to Low
Source ...................................................................................................................................................... 571
430. 677.3-SE324: Engine Starter Motor Relay Circuit - Voltage Above Normal or Shorted to High
Source ...................................................................................................................................................... 572
431. 3060.18-SE12227: Engine Cooling System Monitor - Data Valid But Below Normal Operating
Range - Moderately Severe Level ............................................................................................................. 573
432. 237.13-SE7946: Vehicle Identification Number - Out of Calibration ............................................ 575
433. 630.12-SE2909: Engine Control Module Calibration Memory Software - Bad Intelligent Device or
Component ............................................................................................................................................... 576
434. 103.7-SE12073: Engine Turbocharger 1 Speed - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 577
435. 103.16-SE3641: Turbocharger 1 Speed - Data Valid But Above Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 578
436. 103.18-SE3642: Turbocharger 1 Speed - Data Valid But Below Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 579
437. 103.15-SE2023: Turbocharger 1 Speed - Data Valid But Above Normal Operating Range - Least
Severe Level .............................................................................................................................................. 580
438. 3361.3-SE7289: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 581

Cummins Inc. Revision Date: March 30, 2017 19


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

439. 3361.4-SE7290: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 582
440. 4375.3-SE6095: Aftertreatment 1 Diesel Exhaust Fluid Pump Command Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 583
441. 4375.4-SE6094: Aftertreatment 1 Diesel Exhaust Fluid Pump Command Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 584
442. 4334.16-SE7004: Aftertreatment 1 Diesel Exhaust Fluid Pressure - Data Valid But Above Normal
Operating Range - Moderately Severe Level ............................................................................................ 585
443. 4334.18-SE7005: Aftertreatment 1 Diesel Exhaust Fluid Pressure - Data Valid But Below Normal
Operating Range - Moderately Severe Level ............................................................................................ 586
444. 3364.3-SE8691: Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 587
445. 3364.4-SE8692: Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 589
446. 3364.2-SE8693: Aftertreatment Diesel Exhaust Fluid Quality - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 590
447. 3521.18-SE13411: Aftertreatment 1 Diesel Exhaust Fluid Property - Data Valid But Below Normal
Operating Range - Moderately Severe Level ............................................................................................ 591
448. 3364.11-SE6996: Aftertreatment Diesel Exhaust Fluid Quality - Root Cause Not Known............ 592
449. 3364.18-SE7282: Aftertreatment Diesel Exhaust Fluid Quality - Data Valid But Below Normal
Operating Range - Moderately Severe Level ............................................................................................ 594
450. 3521.16-SE13409: Aftertreatment 1 Diesel Exhaust Fluid Property - Data Valid But Above Normal
Operating Range - Moderately Severe Level ............................................................................................ 595
451. 3521.31-SE13410: Aftertreatment 1 Diesel Exhaust Fluid Property - Condition Exists ................ 596
452. 3364.10-SE7286: Aftertreatment Diesel Exhaust Fluid Quality - Abnormal Rate of Change ....... 597
453. 3515.10-SE7285: Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 - Abnormal Rate of
Change ...................................................................................................................................................... 598
454. 3515.3-SE6981: Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit - Voltage
Above Normal or Shorted to High Source ................................................................................................ 599
455. 3515.4-SE6982: Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 601
456. 3521.11-SE8690: Aftertreatment 1 Diesel Exhaust Fluid Property - Root Cause Not Known ...... 602
457. 4334.2-SE11203: Aftertreatment 1 Diesel Exhaust Fluid Pressure - Data Erratic, Intermittent, or
Incorrect .................................................................................................................................................... 604
458. 4334.3-SE5579: Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 606

Cummins Inc. Revision Date: March 30, 2017 20


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

459. 4334.4-SE5580: Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 607
460. 4334.7-SE12048: Aftertreatment 1 Diesel Exhaust Fluid Pressure - Mechanical System Not
Responding or Out of Adjustment ............................................................................................................ 608
461. 520953.3-SE11754: Aftertreatment Diesel Exhaust Fluid Dosing Unit Relay Feedback - Voltage
Above Normal or Shorted to High Source ................................................................................................ 609
462. 520953.4-SE11755: Aftertreatment Diesel Exhaust Fluid Dosing Unit Relay Feedback - Voltage
Below Normal or Shorted to Low Source ................................................................................................. 610
463. 3362.31-SE6980: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines - Condition Exists.
...................................................................................................................................................... 611
464. 5394.7-SE7927: Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 - Mechanical System Not
Responding or Out of Adjustment ............................................................................................................ 612
465. 5394.5-SE5102: Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 Circuit - Current Below
Normal or Open Circuit ............................................................................................................................. 614
466. 5394.3-SE11473: Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 615
467. 4340.3-SE11170: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 616
468. 4340.4-SE11167: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 617
469. 4342.3-SE11171: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 618
470. 4342.4-SE11168: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 619
471. 4344.3-SE11172: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 620
472. 4344.4-SE11169: Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 621
473. 4334.15-SE12047: Aftertreatment 1 Diesel Exhaust Fluid Pressure - Data Valid But Above Normal
Operating Range - Least Severe Level ....................................................................................................... 622
474. 3363.18-SE2962: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater - Data Valid But Below
Normal Operating Range - Moderately Severe Level ............................................................................... 623
475. 3363.7-SE2964: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater - Mechanical System Not
Responding or Out of Adjustment ............................................................................................................ 625
476. 3363.16-SE2965: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater - Data Valid But Above
Normal Operating Range - Moderately Severe Level ............................................................................... 627
477. 4096.31-SE5279: Aftertreatment Diesel Exhaust Fluid Tank Empty - Condition Exists ................ 628

Cummins Inc. Revision Date: March 30, 2017 21


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

478. 1761.1-SE2906: Aftertreatment 1 Diesel Exhaust Fluid Tank Level - Data Valid But Below Normal
Operating Range - Most Severe Level ....................................................................................................... 629
479. 1761.1-SE4189: Aftertreatment 1 Diesel Exhaust Fluid Tank Level - Data Valid But Below Normal
Operating Range - Most Severe Level ....................................................................................................... 630
480. 1761.17-SE2907: Aftertreatment 1 Diesel Exhaust Fluid Tank Level - Data Valid But Below Normal
Operating Range - Least Severe Level ....................................................................................................... 631
481. 1761.3-SE2896: Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit - Voltage Above
Normal or Shorted to High Source............................................................................................................ 632
482. 1761.4-SE2897: Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 634
483. 1761.10-SE8684: Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor - Abnormal Rate of
Change ...................................................................................................................................................... 635
484. 1761.11-SE8293: Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor - Root Cause Not
Known ...................................................................................................................................................... 637
485. 1761.18-SE4188: Aftertreatment 1 Diesel Exhaust Fluid Tank Level - Data Valid But Below Normal
Operating Range - Moderately Severe Level ............................................................................................ 638
486. 3031.2-SE3650: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature - Data Erratic,
Intermittent, or Incorrect ......................................................................................................................... 639
487. 3031.3-SE2898: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor - Voltage Above
Normal or Shorted to High Source............................................................................................................ 640
488. 3031.4-SE2899: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor - Voltage Below
Normal or Shorted to Low Source ............................................................................................................ 642
489. 3031.11-SE8291: Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature - Root Cause Not
Known ...................................................................................................................................................... 644
490. 5491.3-SE6100: Aftertreatment Diesel Exhaust Fluid Line Heater Relay - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 645
491. 5491.4-SE6101: Aftertreatment Diesel Exhaust Fluid Line Heater Relay - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 646
492. 3363.3-SE6102: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater - Voltage Above Normal or
Shorted to High Source ............................................................................................................................. 647
493. 3363.4-SE6103: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater - Voltage Below Normal or
Shorted to Low Source .............................................................................................................................. 648
494. 5321.31-SE8281: Engine Intake Manifold Pressure System Monitor - Condition Exists .............. 649
495. 641.7-SE1606: VGT Actuator Driver Circuit (Motor) - Mechanical System Not Responding or Out
of Adjustment ........................................................................................................................................... 650
496. 641.11-SE1627: VGT Actuator Driver Circuit - Root Cause Not Known ........................................ 651
497. 641.12-SE1604: VGT Actuator Controller - Bad Intelligent Device or Component....................... 652

Cummins Inc. Revision Date: March 30, 2017 22


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

498. 641.14-SE1605: VGT Actuator Controller - Special Instructions ................................................... 653


499. 641.15-SE1607: VGT Actuator Driver Temperature - Data Valid But Above Normal Operating
Range - Least Severe Level ........................................................................................................................ 654
500. 3597.4-SE1602: ECU Power Output Supply Voltage 1 - Voltage Below Normal or Shorted to Low
Source ...................................................................................................................................................... 655
501. 3597.18-SE1626: ECU Power Output Supply Voltage 1 - Data Valid But Below Normal Operating
Range - Moderately Severe Level ............................................................................................................. 656
502. 84.2-SE7458: Wheel-Based Vehicle Speed - Data Erratic, Intermittent, or Incorrect .................. 657
503. 84.2-SE7483: Wheel-Based Vehicle Speed - Data Erratic, Intermittent, or Incorrect .................. 658
504. 84.2-SE4360: Wheel-Based Vehicle Speed - Data Erratic, Intermittent, or Incorrect .................. 659
505. 84.2-SE4361: Wheel-Based Vehicle Speed - Data Erratic, Intermittent, or Incorrect .................. 660
506. 84.2-SE130: Wheel-Based Vehicle Speed - Data Erratic, Intermittent, or Incorrect .................... 661
507. 97.15-SE280: Water in Fuel Indicator - Data Valid But Above Normal Operating Range - Least
Severe Level .............................................................................................................................................. 662
508. 97.16-SE1612: Water in Fuel Indicator - Data Valid But Above Normal Operating Range -
Moderately Severe Level .......................................................................................................................... 663
509. 97.3-SE660: Water in Fuel Indicator Sensor Circuit - Voltage Above Normal or Shorted to High
Source ...................................................................................................................................................... 664
510. 1081.7-SE7231: Engine Wait to Start Lamp - Mechanical System Not Responding or Out of
Adjustment ............................................................................................................................................... 665
511. RefCondRefCond3.7: Exhaust gas temperature is below a threshold representing that dew point
is not reached ........................................................................................................................................... 666
512. RefCondRefCond4.4: SCR Outlet Temperature sensor reading is valid. ....................................... 667
513. RefCondRefCond5.4: NOx Outlet sensor SCR hot start delay logic is allowed to run. ................. 668
514. RefCondRefCond7.6: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. ................................. 669
515. RefCondRefCond8.5: NOx sensor reading is not valid due to internal control loops within the
sensor being unstable.. ............................................................................................................................. 670
516. RefCondRefCond9.6: Exhaust gas temperature is below a threshold or above a threshold for
insufficient time representing that dew point is not reached. ................................................................. 671
517. RefCondRefCond10.4: Datalinks-related faults are inhibited for a calibratable amount of time
following a key-on event, a low battery voltage event, an engine cranking event, and a stop/suspend
broadcast event. This is to allow reasonable time for datalink devices to power up and begin periodic
broadcasts before the ECM performs time-out diagnostics..................................................................... 672
518. RefCondRefCond17.3: NOx sensor reading is valid since the internal control loops within the
sensor have stabilized. .............................................................................................................................. 673

Cummins Inc. Revision Date: March 30, 2017 23


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

519. RefCondRefCond19.8: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. ................................. 674
520. RefCondRefCond20.10: Aftertreatment Outlet NOx sensor reading is valid since the internal
control loops within the sensor are stable, and no active faults detected by the sensor, and the sensor's
battery supply voltage is within the desired range and dewpoint temperature has been met for a
sufficient time to allow the sensor to light off. ........................................................................................ 675
521. RefCondRefCond24.57: When NH3 slip is detected, corrective action is taken. Commanded ANR
is decreased by temporarily stepping down the target SCR conversion efficiency. ................................. 676
522. RefCondRefCond25.3: Exhaust gas temperature as measured by the exhaust gas temperature
sensor closest to the PM sensor is above a threshold representing the point at which there is no longer a
concern of condensation on the PM sensor sensing element.................................................................. 677
523. RefCondRefCond26.1: Battery voltage is within range. ............................................................... 678
524. RefCondRefCond28.9: %O2 reading of Exhaust Air virtual sensor is valid ................................... 679
525. RefCondRefCond29.2: Urea Quality Sensor (UQS) temperature sensor element shorted to a high
source. ...................................................................................................................................................... 680
526. RefCondRefCond30.2: Unknown failure of the UQS concentration detection element, or UQS
Concentration detection element voltage shorted out of range low....................................................... 681
527. RefCondRefCond32.3: the disable conditions for the diagnostic are specified as follows........... 682
528. RefCondRefCond33.2: Urea Quality Sensor (UQS) temperature sensing element shorted to a low
source. ...................................................................................................................................................... 683
529. RefCondRefCond34.4: the enable conditions for the diagnostic are specified as follows ........... 684
530. RefCondRefCond35.2: The Urea Quality Sensor (UQS) is located in tank. ................................... 685
531. RefCondRefCond36.2: Urea Quality Sensor (UQS) temperature sensor element shorted to a low
source. ...................................................................................................................................................... 686
532. RefCondRefCond37.2: Urea Quality Sensor (UQS) temperature sensor element shorted to a high
source. ...................................................................................................................................................... 687
533. RefCondRefCond39.2: the sensor has completed the DEF type detection process, and has
determined that the fluid in the DEF tank is not DEF ............................................................................... 688
534. RefCondRefCond40.1: The sensor has completed the DEF type detection process, and has
determined that the fluid in the DEF tank is not DEF. .............................................................................. 689
535. RefCondRefCond42.2: UQS Concentration detection element voltage shorted out of range high. ..
...................................................................................................................................................... 690
536. RefCondRefCond43.2: UQS Concentration detection element voltage shorted out of range high. ..
...................................................................................................................................................... 691
537. RefCondRefCond44.2: UQS Concentration detection element voltage shorted out of range low. ...
...................................................................................................................................................... 692
538. RefCondRefCond52.37: the pause conditions for the diagnostic are specified as follows .......... 693

Cummins Inc. Revision Date: March 30, 2017 24


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

539. RefCondRefCond58.49: the disable conditions for the diagnostic are specified as follows......... 694
540. RefCondRefCond60.53: the enable conditions for the diagnostic are specified as follows ......... 695
541. RefCondRefCond61.4: SCR Outlet Temperature sensor reading is suspected and not yet
confirmed as faulty. .................................................................................................................................. 696
542. RefCondRefCond63.7: OBD Arbitrator allows Quantity and Timing Diagnostics ......................... 697
543. RefCondRefCond64.2: DPF Outlet Temperature sensor reading is suspected and not yet
confirmed as faulty. .................................................................................................................................. 698
544. RefCondRefCond65.2: DOC Outlet Temperature sensor reading is suspected and not yet
confirmed as faulty. .................................................................................................................................. 699
545. RefCondRefCond66.2: DOC Inlet Temperature sensor reading is suspected and not yet confirmed
as faulty. .................................................................................................................................................... 700
546. RefCondRefCond67.3: the disable conditions for the diagnostic are specified as follows........... 701
547. RefCondRefCond68.4: the enable conditions for the diagnostic are specified as follows ........... 702
548. RefCondRefCond69.9: Aftertreatment Inlet NOx sensor reading is not valid. ............................. 703
549. RefCondRefCond72.4: the disable conditions for the diagnostic are specified as follows........... 704
550. RefCondRefCond73.4: the enable conditions for the diagnostic are specified as follows ........... 705
551. RefCondRefCond77.48: The DEF Supply Module has begun filling with DEF ............................... 706
552. RefCondRefCond84.19: Dosing Not Allowed Flag indicating Dosing command is out of nominal
range for Urea Doser Functional Monitor ................................................................................................ 707
553. RefCondRefCond86.9: Aftertreatment Outlet NOx sensor O2 reading is valid since the internal
control loops within the sensor are stable, and no active faults detected by the sensor, and the sensor's
battery supply voltage is within the desired range and dewpoint temperature has been met for a
sufficient time to allow the sensor to light off. ........................................................................................ 708
554. RefCondRefCond87.5: The DEF Supply Module (SM) has completed pump pressure control and is
ready to dose. ........................................................................................................................................... 709
555. RefCondRefCond88.5: SCR Conversion Efficiency Relay feedback mode is commanding very high
ANR. ...................................................................................................................................................... 710
556. RefCondRefCond89.14: SCR Conversion Efficiency Relay feedback mode is commanding high
dosing for accelerated ammonia storage in SCR first brick ...................................................................... 711
557. RefCondRefCond91.69: Closed loop control of DEF dosing is allowed......................................... 712
558. RefCondRefCond93.11: Aftertreatment Outlet NOx sensor reading is not valid due to internal
control loops within the sensor being unstable, or active faults detected by the sensor, or the sensor's
battery supply voltage is outside the desired range or dewpoint temperature not met. ....................... 713
559. RefCondRefCond99.1: Conditions to prohibit DEF priming or initiate DEF purging for the system
due to low ambient temperature. ............................................................................................................ 714
560. RefCondRefCond100.19: Conditions to determine whether Urea Tank is frozen or not. ............ 715
561. RefCondRefCond103.79: All common enable condition for control loop used up is active ........ 716

Cummins Inc. Revision Date: March 30, 2017 25


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

562. RefCondRefCond104.79: SCR Inner loop used up enable conditions are true. ............................ 717
563. RefCondRefCond107.49: the disable conditions for the diagnostic are specified as follows....... 718
564. RefCondRefCond108.37: the pause conditions for the diagnostic are specified as follows ........ 719
565. RefCondRefCond109.53: The enable conditions for the low concentration diagnostic are specified
as follows .................................................................................................................................................. 720
566. RefCondRefCond110.56: the disable conditions for the diagnostic are specified as follows....... 721
567. RefCondRefCond111.60: the enable conditions for the diagnostic are specified as follows ....... 722
568. RefCondRefCond113.57: the pause conditions for the diagnostic are specified as follows ........ 723
569. RefCondRefCond114.4: Active errors within the SCR system that will disable active/intrusive
injection of HCs into the exhaust in order to protect the SCR system ..................................................... 724
570. RefCondRefCond115.5: Malfunction criteria for the algorithm that detects an ineffective
regeneration of the DPF. (Detection of ineffective regeneration aborts the current active regeneration
of the DPF.) ............................................................................................................................................... 725
571. RefCondRefCond122.2: The fault due to Inhibit Switch timed regeneration is not active. ......... 726
572. RefCondRefCond127.12: Urea Doser Functional Response Monitor is ready to update the fault. ...
...................................................................................................................................................... 727
573. RefCondRefCond129.5: SCR Bed temperature reset condition based on the module off time. .. 728
574. RefCondRefCond130.22: Exhaust gas temperature is below a threshold representing that dew
point is not reached .................................................................................................................................. 729
575. RefCondRefCond132.7: Abort condition to disable the diagnostics when ambient temperature or
pressure are outside limit threshold values. ............................................................................................ 730
576. RefCondRefCond135.2: UQS sensor internal temperature is above the maximum operating range
...................................................................................................................................................... 731
577. RefCondRefCond136.4: the enable conditions for the diagnostic are specified as follows ......... 732
578. RefCondRefCond137.3: the disable conditions for the diagnostic are specified as follows......... 733
579. RefCondRefCond139.16: Enable conditions for the tests run during motoring. .......................... 734
580. RefCondRefCond143.3: VGT driver failure ................................................................................... 735
581. RefCondRefCond144.4: The VGT Position is not known to be good. ........................................... 736
582. RefCondRefCond145.4: The Intake Air Throttle Valve Position is not known to be good. .......... 737
583. RefCondRefCond146.5: The EGR H-bridge valve position is not valid. ......................................... 738
584. RefCondRefCond148.4: No Active Ambient Air Temperature System Errors .............................. 739
585. RefCondRefCond149.5: Any Active Air Temperature System Errors ............................................ 740
586. RefCondRefCond152.51: Conditions that enable the calculation of conversion efficiency of an
oxidation catalyst. ..................................................................................................................................... 741
587. RefCondRefCond154.22: Conditions that pause the calculation of conversion efficiency of an
oxidation catalyst. ..................................................................................................................................... 742

Cummins Inc. Revision Date: March 30, 2017 26


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

588. RefCondRefCond156.4: The system detects that the DPF is no longer new, or "green". New DPF
temporarily exhibits high backpressure during their first hours of use which can lead to a false high
estimation of soot load. ............................................................................................................................ 743
589. RefCondRefCond157.4: The system considers that the DPF is new, or "green". New DPF
temporarily exhibits high backpressure during their first hours of use which can lead to a false high
estimation of soot load. ............................................................................................................................ 744
590. RefCondRefCond159.23: The exhaust temperature as measured by the sensor closest to the PM
sensor is warm. ......................................................................................................................................... 745
591. RefCondRefCond160.23: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the PM sensor element. ................................... 746
592. RefCondRefCond167.8: Aftertreatment Outlet NOx sensor reading is not valid due to internal
control loops within the sensor being unstable, or active faults detected by the sensor, or the sensor's
battery supply voltage is outside the desired range or dewpoint temperature not met. ....................... 747
593. RefCondRefCond168.1: Enable conditions for the algorithm that detects an ineffective
regeneration of the DPF............................................................................................................................ 748
594. RefCondRefCond169.1: Abort conditions for the algorithm that detects an ineffective
regeneration of the DPF............................................................................................................................ 749
595. RefCondRefCond170.5: Pause conditions for the algorithm that detects an ineffective
regeneration of the DPF............................................................................................................................ 750
596. RefCondRefCond171.1: Average of three exhaust gas temperatures is less than a calibratable
threshold OR ECM Off Time is data valid and greater than a calibratable threshold............................... 751
597. RefCondRefCond172.5: SCR Bed temperature reset condition based on the module off time. .. 752
598. RefCondRefCond174.3: A block heater is not detected. .............................................................. 753
599. RefCondRefCond176.4: Slow Actuator Response: The engine conditions must be appropriate to
avoid a false detect of a stuck actuator. ................................................................................................... 754
600. RefCondRefCond177.5: Slow Actuator Response: The turbocharger smart device has detected
that it cannot meet its commanded position within an acceptable time. ............................................... 755
601. RefCondRefCond179.1: Message Timeout: The turbocharger smart device has not received a
position command message for greater than or equal to a calibrated time after previously having
received a command message. ................................................................................................................. 756
602. RefCondRefCond180.1: No Source: The turbocharger smart device has not received a message
from the ECM. ........................................................................................................................................... 757
603. RefCondRefCond182.1: The turbocharger smart device has detected an internal error which will
prevent it from functioning normally. ...................................................................................................... 758
604. RefCondRefCond184.1: The turbocharger smart device has not detected a physical stop during
the powerup process. ............................................................................................................................... 759
605. RefCondRefCond187.1: The voltage for the turbocharger smart device is less than a calibrated
value. ...................................................................................................................................................... 760

Cummins Inc. Revision Date: March 30, 2017 27


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

606. RefCondRefCond188.4: Estimated aftertreatment inlet gas temperature is valid. .................... 761
607. RefCondRefCond194.3: SCR conversion efficiency variation term settles down. ........................ 762
608. RefCondRefCond197.18: Condition to abort the diagnostic based on the value of battery voltage
and engine cranking state ......................................................................................................................... 763
609. RefCondRefCond198.2: Ambient air temperature is data valid. .................................................. 764
610. RefCondRefCond200.1: PM sensor is in measurement mode for too long, with out making a
diagnostic increment or decrement decision. .......................................................................................... 765
611. RefCondRefCond201.5: Exhaust flow and temperature conditions are favorable for a succesful
PM sensor regeneration. .......................................................................................................................... 766
612. RefCondRefCond203.1: PM sensor has reactivated and exited measurement mode greater than
or equal to a calibratable number of occurance counts prior to making a decision in the current drive
cycle. ...................................................................................................................................................... 767
613. RefCondRefCond204.3: PM sensor probe temperature and exhaust temperature at sensor
closest to the PM sensor should be within a range for the sensor measurement to be enabled. .......... 768
614. RefCondRefCond225.1: DEF tank temperature sensor element shorted to a high source. ......... 769
615. RefCondRefCond226.1: DEF tank temperature sensor element shorted to a low source. .......... 770
616. RefCondRefCond227.2: DEF tank temperature sensor element shorted to a high source or open
circuit. ...................................................................................................................................................... 771
617. RefCondRefCond229.2: the enable conditions for the diagnostic are specified as follows ......... 772
618. RefCondRefCond230.2: the disable conditions for the diagnostic are specified as follows......... 773
619. RefCondRefCond231.2: DEF tank temperature sensor element shorted to a low source. .......... 774
620. RefCondRefCond232.1: The engine is cold soaked....................................................................... 775
621. RefCondRefCond237.6: Urea Doser Functional Response Monitor updates the fault and Urea
Doser Functional Response Monitor System Error is not active .............................................................. 776
622. RefCondRefCond249.2: the disable conditions for the diagnostic are specified as follows......... 777
623. RefCondRefCond250.2: the enable conditions for the diagnostic are specified as follows ......... 778
624. RefCondRefCond251.2: Conditions stating ambient air temperature is cold .............................. 779
625. RefCondRefCond252.2: DEF level detection element voltage shorted to a low source. ............. 780
626. RefCondRefCond253.2: DEF level detection element voltage shorted to a high source or open
circuit. ...................................................................................................................................................... 781
627. RefCondRefCond254.1: the enable conditions for the diagnostic are specified as follows ......... 782
628. RefCondRefCond256.4: the enable conditions for the diagnostic are specified as follows ......... 783
629. RefCondRefCond257.1: the disable conditions for the diagnostic are specified as follows......... 784
630. RefCondRefCond258.4: the disable conditions for the diagnostic are specified as follows......... 785
631. RefCondRefCond259.2: DEF level detection element voltage shorted out of range high. .......... 786

Cummins Inc. Revision Date: March 30, 2017 28


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

632. RefCondRefCond260.1: Unknown failure of the DEF level detection element, or DEF level
detection element shorted out of range low. .......................................................................................... 787
633. RefCondRefCond261.22: the enable conditions for the diagnostic are specified as follows ....... 788
634. RefCondRefCond262.22: the disable conditions for the diagnostic are specified as follows....... 789
635. RefCondRefCond263.22: the pause conditions for the diagnostic are specified as follows ........ 790
636. RefCondRefCond267.1: Fluid level in the DEF tank as measured by the DEF tank level sensor is
below the Empty Calibration set point. .................................................................................................... 791
637. RefCondRefCond307.2: The turbocharger smart device has detected a warm temperature
condition. .................................................................................................................................................. 792
638. RefCondRefCond308.1: the enable conditions for the diagnostic are specified as follows ......... 793
639. RefCondRefCond309.2: the enable conditions for the diagnostic are specified as follows ......... 794
640. RefCondRefCond310.1: The disable conditions for the diagnostic are specified as follows. ....... 795
641. RefCondRefCond311.2: the disable conditions for the diagnostic are specified as follows......... 796
642. RefCondRefCond312.2: the enable conditions for the diagnostic are specified as follows ......... 797
643. RefCondRefCond313.2: the disable conditions for the diagnostic are specified as follows......... 798
644. RefCondRefCond315.18: the enable conditions for the diagnostic are specified as follows ....... 799
645. RefCondRefCond316.24: the disable conditions for the diagnostic are specified as follows....... 800
646. RefCondRefCond317.28: The enable conditions for the diagnostic are specified as follows ...... 801
647. RefCondRefCond318.32: The disable conditions for the diagnostic are specified as follows ...... 802
648. RefCondRefCond319.27: The disable conditions for the diagnostic are specified as follows ...... 803
649. RefCondRefCond320.33: The enable conditions for the diagnostic are specified as follows ...... 804
650. RefCondRefCond321.28: The disable conditions for the diagnostic are specified as follows ...... 805
651. RefCondRefCond322.28: The enable conditions for the diagnostic are specified as follows ...... 806
652. RefCondRefCond368.1: Engine running condition ....................................................................... 807
653. RefCondRefCond369.1: Ambient Air Temperature status is valid................................................ 808
654. RefCondRefCond370.1: Urea Quality Sensor (UQS) temperature sensor element shorted to a high
source. ...................................................................................................................................................... 809
655. RefCondRefCond371.1: UQS Concentration detection element voltage shorted out of range low. .
...................................................................................................................................................... 810
656. RefCondRefCond372.1: UQS Concentration detection element voltage shorted out of range high.
...................................................................................................................................................... 811
657. RefCondRefCond373.1: Conditions stating ambient air temperature is cold .............................. 812
658. RefCondRefCond374.1: Urea Quality Sensor (UQS) temperature sensor element shorted to a low
source. ...................................................................................................................................................... 813

Cummins Inc. Revision Date: March 30, 2017 29


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

659. RefCondRefCond376.1: The status of in-tank mounted measurement of DEF concentration


quality is data error no value. ................................................................................................................... 814
660. RefCondRefCond381.2: DOC Inlet temperature sensor data is not available and not yet confirmed
as faulty. .................................................................................................................................................... 815
661. RefCondRefCond382.2: DOC Inlet temperature sensor have no value and not yet confirmed as
faulty. ...................................................................................................................................................... 816
662. RefCondRefCond383.2: DOC Outlet temperature sensor data is not available and not yet
confirmed as faulty. .................................................................................................................................. 817
663. RefCondRefCond384.2: DOC Outlet temperature sensor have no value and not yet confirmed as
faulty. ...................................................................................................................................................... 818
664. RefCondRefCond385.2: DPF Outlet temperature sensor data is not available and not yet
confirmed as faulty. .................................................................................................................................. 819
665. RefCondRefCond386.2: DPF Outlet temperature sensor have no value and not yet confirmed as
faulty. ...................................................................................................................................................... 820
666. RefCondRefCond412.1: Ambient air temperature is cold ............................................................ 821
667. RefCondRefCond413.3: The DEF recirculation is active due to hot shutdown............................. 822
668. RefCondRefCond414.1: Flag indicating that Engine is in Derate and Urea Doser Functional
Response Monitor fault is active. ............................................................................................................. 823
669. RefCondRefCond418.2: SCR Outlet temperature sensor data is not available and not yet
confirmed as faulty. .................................................................................................................................. 824
670. RefCondRefCond420.1: SCR Out temperature sensor reading no value and not yet confirmed as
faulty. ...................................................................................................................................................... 825
671. RefCondRefCond421.1: Block heater is detected ......................................................................... 826
672. RefCondRefCond426.2: the enable conditions for the diagnostic are specified as follows ......... 827
673. RefCondRefCond427.2: the disable conditions for the diagnostic are specified as follows......... 828
674. RefCondRefCond428.2: the enable conditions for the diagnostic are specified as follows ......... 829
675. RefCondRefCond429.2: the disable conditions for the diagnostic are specified as follows......... 830
676. RefCondRefCond430.3: The in-tank mounted measurement of DEF tank level is valid without
considering cold ambient conditions ........................................................................................................ 831
677. RefCondRefCond454.1: Average SCR out temperature buffer is not full ..................................... 832
678. RefCondRefCond455.2: Fuel system failure is not present .......................................................... 833
679. RefCondRefCond456.2: The inverted disable conditions for the diagnostic are specified as follows
...................................................................................................................................................... 834
680. RefCondRefCond457.1: UQS sensor internal temperature is above the maximum operating range
...................................................................................................................................................... 835
681. RefCondRefCond458.1: Unknown failure of the UQS concentration detection element, or UQS
Concentration detection element voltage shorted out of range low....................................................... 836

Cummins Inc. Revision Date: March 30, 2017 30


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

682. RefCondRefCond459.1: DEF tank temperature sensor element shorted to a high source or open
circuit. ...................................................................................................................................................... 837
683. RefCondRefCond460.1: DEF tank temperature sensor element shorted to a low source. .......... 838
684. RefCondRefCond461.2: Conditions to enable the Key-Off Pressure Decay diagnostics .............. 839
685. RefCondRefCond462.2: Condition to check the DEF pressure value at the rising event when
KeyOff pressure decay diagnostics is enabled .......................................................................................... 840
686. RefCondRefCond463.2: The returnline blockage diagnostics is complete when the diagnostics has
been enabled for a calibrated period of time ........................................................................................... 841
687. RefCondRefCond464.2: Conditions to check if the returnline blockage diagnostic error flag has
been set. ................................................................................................................................................... 842
688. RefCondRefCond465.2: Conditions to check if the Sensor Stuck diagnostics is complete ........... 843
689. RefCondRefCond466.1: DPF delta pressure sensor error is detected. ......................................... 844
690. RefCondRefCond467.1: Active faults with DPF delta pressure sensor defaulted. ....................... 845
691. RefCondRefCond468.1: Dosing check conditions for Non-Regen severe temperature faults. .... 846
692. RefCondRefCond469.2: Enable Conditions for DEF dosing command adjustment. .................... 847
693. RefCondRefCond475.2: Reactive regen trigger is active. ............................................................. 848
694. RefCondRefCond476.2: Decomposition Reactor Pipe (DRP) regeneration request is not active 849
695. RefCondRefCond477.38: The enable conditions for the diagnostic are specified as follows ...... 850
696. RefCondRefCond478.38: DEF intrusive dosing window is active ................................................. 851
697. RefCondRefCond480.1: The enable conditions for the DEF Tank Temperature Internal error
diagnostic are specified as follows............................................................................................................ 852
698. RefCondRefCond481.1: The disable conditions for the DEF Tank Temperature Internal error
diagnostic are specified as follows............................................................................................................ 853
699. RefCondRefCond485.1: DPF delta pressure sensor error is not detected. .................................. 854
700. RefCondRefCond486.1: Enable Solid Lamp based on regeneration of DPF trigger states. .......... 855
701. RefCondRefCond489.1: The sensor has completed the DEF type detection process, and has
determined that the fluid in the DEF tank is not DEF. .............................................................................. 856
702. RefCondRefCond490.2: Conditions to abort the Key-Off Pressure Decay diagnostics................. 857
703. RefCondRefCond491.1: DEF level detection element voltage shorted to a high source or open
circuit. ...................................................................................................................................................... 858
704. RefCondRefCond492.1: DEF level detection element voltage shorted to a low source. ............. 859
705. RefCondRefCond500.2: Reductant delivery monitor frequency check is satisfied ...................... 860
706. RefCondRefCond507.1: Any of the DEF Doser related errors are active. ..................................... 861
707. RefCondRefCond508.1: Any of the DEF Doser related errors are active. ..................................... 862
708. RefCondRefCond509.2: Aftertreatment Inlet NOx sensor reading is not valid. ........................... 863

Cummins Inc. Revision Date: March 30, 2017 31


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

709. RefCondRefCond668.1: Engine control module off time is greater thean a calibrated threshold.....
...................................................................................................................................................... 864

Cummins Inc. Revision Date: March 30, 2017 32


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1. 2623.3-SE1378: Accelerator Pedal or Lever Position Sensor 2


Circuit - Voltage Above Normal or Shorted to High Source
Secondary Accelerator Pedal Position Out-of-Range High

Monitor Operation:
DTC 2623.3-SE1378
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


2623.4-SE1379
3513.3-SE1893
3513.4-SE1894

Pause Conditions (any active):


2623.4-SE1379
3513.3-SE1893
3513.4-SE1894

Malfunction Thresholds (all active):


Secondary Accelerator Pedal Position Sensor Value > 2.419 V (100 %)

Cummins Inc. Revision Date: March 30, 2017 33


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

2. 2623.4-SE1379: Accelerator Pedal or Lever Position Sensor 2


Circuit - Voltage Below Normal or Shorted to Low Source
Secondary Accelerator Pedal Position Out-of-Range Low

Monitor Operation:
DTC 2623.4-SE1379
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3513.3-SE1893
3513.4-SE1894

Pause Conditions (any active):


3513.3-SE1893
3513.4-SE1894

Malfunction Thresholds (all active):


Secondary Accelerator Pedal Position Sensor Value < 0.323 V (0 %)

Cummins Inc. Revision Date: March 30, 2017 34


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3. 167.16-SE378: Electrical Charging System Voltage - Data Valid But


Above Normal Operating Range - Moderately Severe Level
Alternator Failure Warning voltage is above voltage limit.

Monitor Operation:
DTC 167.16-SE378
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Startup delay time ≥ 600 sec

Malfunction Thresholds (all active):


Alternator Failure Warning Voltage ≥ 16 V

Cummins Inc. Revision Date: March 30, 2017 35


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

4. 167.18-SE379: Electrical Charging System Voltage - Data Valid But


Below Normal Operating Range - Moderately Severe Level
Alternator Failure Warning voltage is below low voltage limit and above very low voltage limit.

Monitor Operation:
DTC 167.18-SE379
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Startup delay time > 600 sec

Malfunction Thresholds (all active):


Alternator Failure Warning Voltage <= 12 V
Alternator Failure Warning Voltage > 0 V

Cummins Inc. Revision Date: March 30, 2017 36


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

5. 171.2-SE3799: Ambient Air Temperature - Data Erratic,


Intermittent, or Incorrect
Air Temperature reading is In Range High

Monitor Operation:
DTC 171.2-SE3799
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 150 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


171.3-SE3802, 171.4-SE3803
171.2-SE3871
Engine is not in run state

Malfunction Thresholds (all active):


Ambient Air Temperature > 95 degC AND Average of (Ambient Air Temperature - Estimated Ambient
Air Temperature) over a 150 second period is ever ≥ 2 degC Diagnostic Tolerance = 72.5 degC (Please
refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 37


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

6. 171.2-SE3871: Ambient Air Temperature - Data Erratic,


Intermittent, or Incorrect
Air Temperature sensor reading is erratic, intermittent or incorrect.

Monitor Operation:
DTC 171.2-SE3871
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine off time ≥ 480 min
The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Abort Conditions (any active):


171.3-SE3802, 171.4-SE3803
251.10-SE4759
251.10-SE4760

Malfunction Thresholds (all active):


| Air Temperature sensor - the most accurate sensor from the remaining temperature sensors | > (35
degC + the tolerance of the most accurate sensor from the remaining temperature sensors)
| Air Temperature sensor - the second most accurate sensor from the remaining temperature sensors
| > (35 degC + the tolerance of the second most accurate sensor from the remaining temperature
sensors)
| the most accurate sensor from the remaining temperature sensors - the second most accurate
sensor from the remaining temperature sensors | < (the tolerance of the most accurate sensor from
the remaining temperature sensors + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
The tolerance of the remaining temperature sensors are:
Compressor Inlet Temperature sensor tolerance = 40 °C
Charge Temperature sensor tolerance = 21 °C
Coolant Temperature sensor tolerance = 20 °C
ECM Internal Temperature sensor tolerance = 210 °C
EGR Orifice Temperature sensor tolerance = 25 °C

Cummins Inc. Revision Date: March 30, 2017 38


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7. 171.3-SE3802: Ambient Air Temperature Sensor 1 Circuit - Voltage


Above Normal or Shorted to High Source
Air Temperature sensor reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 171.3-SE3802
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Air Temperature Sensor value > 4.944 V (< -48.113 degC)

Cummins Inc. Revision Date: March 30, 2017 39


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

8. 171.4-SE3803: Ambient Air Temperature Sensor 1 Circuit - Voltage


Below Normal or Shorted to Low Source
Air Temperature sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 171.4-SE3803
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Air Temperature Sensor value < 0.107V (> 150 degC)

Cummins Inc. Revision Date: March 30, 2017 40


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

9. 5571.7-SE5446: High Pressure Common Rail Fuel Pressure Relief


Valve - Mechanical System Not Responding or Out of Adjustment
Monitor the pop off pressure of the 2-stage Mechanical Dump Valve (MDV) when it is tripped. This is a
supplement monitor to system error 5571.0-SE914 that sets fault when MDV pops below specified
release pressure.

Monitor Operation:
DTC 5571.7-SE5446
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1.5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine is running.
Peak rail pressure across one cam cycle > 1,900 bar OR (rail pressure at current crank tooth - rail
pressure at 2 firing intervals ago < RefTable25.1 bar) AND (rail pressure 2 firing intervals ago > 1,400
bar)
The crankshaft target synchronization gap is identified AND the crankshaft sensor signal is used to
calculate engine speed.
The number of failed MDV reset events in this driving cycle < 5 counts

Abort Conditions (any active):


1347.2-SE915
157.3-SE525

Pause Conditions (any active):


Engine is stopped.
The crankshaft target synchronization gap is not identified AND the camshaft sensor signal is used to
calculate engine speed.
The number of failed MDV reset events in this driving cycle = 5 counts

Malfunction Thresholds (all active):


(Rail pressure command ≥ 1,530 bar AND Peak rail pressure across one cam cycle < rail pressure
command – 200 bar) OR (Rail pressure command = 1,530 bar AND Peak pressure across one cam cycle
< 1,330 bar)
MDV pop off pressure < 1,920 bar
The number of failed MDV reset events in this driving cycle ≥ 2 counts

Cummins Inc. Revision Date: March 30, 2017 41


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

10. 5571.0-SE914: High Pressure Common Rail Fuel Pressure Relief


Valve - Data Valid But Above Normal Operating Range - Most
Severe Level
Monitor the fuel pressure to check the status of the Mechanical Dump Valve (MDV) when the fuel
pressure exceeds a calibrated threshold or the pressure drop across a calibrated interval exceeds a
calibrated threshold.

Monitor Operation:
DTC 5571.0-SE914
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1.5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine is running.
Peak rail pressure across one cam cycle > 1,900 bar OR (rail pressure at current crank tooth - rail
pressure at 2 firing intervals ago < RefTable25.1 bar) AND (rail pressure 2 firing intervals ago > 1,400
bar)
The number of failed MDV reset events in this driving cycle < 5 counts

Abort Conditions (any active):


1347.2-SE915
157.3-SE525

Pause Conditions (any active):


Engine is stopped.
The number of failed MDV reset events in this driving cycle = 5 counts

Malfunction Thresholds (all active):


(Rail pressure command ≥ 1,530 bar AND Peak rail pressure across one cam cycle < rail pressure
command – 200 bar) OR (Rail pressure command = 1,530 bar AND Peak rail pressure across one cam
cycle < 1,330 bar)
The number of failed MDV reset events in this driving cycle ≥ 2 counts

Cummins Inc. Revision Date: March 30, 2017 42


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

11. 157.16-SE522: Injector Metering Rail 1 Pressure - Data Valid But


Above Normal Operating Range - Moderately Severe Level
Monitor Fuel System Performance when measured fuel pressure goes above commanded fuel pressure
by a calibrated threshold .

Monitor Operation:
DTC 157.16-SE522
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


157.7-SE7209, 157.7-SE7211, 157.7-SE7212
Engine Speed > 125 RPM
Battery Voltage > 5 V
The crankshaft target synchronization gap is identified AND the crankshaft sensor signal is used to
calculate engine speed.
Total fueling command ≥ 4 mg/stroke for 7 sec
(Total fueling command < 75 mg/stroke OR 157.16-SE522 NOT ACTIVE) For > 7 sec
Fuel pressure sensor voltage ≥ 0.25 V
Fuel pressure sensor voltage ≤ 4.815 V

Pause Conditions (any active):


157.7-SE7212
Battery Voltage ≤ 5 V
The crankshaft target synchronization gap is not identified AND the camshaft sensor signal is used to
calculate engine speed.
Engine Speed ≤ 125 RPM
Fuel pressure sensor voltage < 0.25 V
Fuel pressure sensor voltage > 4.815 V
Total fueling command ≥ 75 mg/stroke AND 157.16-SE522 ACTIVE
Total fueling command < 4 mg/stroke

Malfunction Thresholds (all active):


The value by which the measured fuel pressure exceeds the pressure command > 100 bar
The high pressure fuel pump flow command ≤ 0.01 g/sec

Cummins Inc. Revision Date: March 30, 2017 43


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

12. 157.18-SE523: Injector Metering Rail 1 Pressure - Data Valid But


Below Normal Operating Range - Moderately Severe Level
Monitor Fuel System Performance when fuel pressure error is greater than a calibrated threshold or
when the measured fuel pressure is less than a calibrated threshold.

Monitor Operation:
DTC 157.18-SE523
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 7 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


157.7-SE7209, 157.7-SE7211, 157.7-SE7212
Engine Speed > 125 RPM
The crankshaft target synchronization gap is identified AND the crankshaft sensor signal is used to
calculate engine speed.
Battery Voltage > 5 V
Fuel pressure sensor voltage ≥ 0.25 V
Fuel pressure sensor voltage ≤ 4.815 V
Mechanical Dump Valve is not tripped

Pause Conditions (any active):


157.7-SE7209, 157.7-SE7211, 157.7-SE7212
Engine Speed ≤ 125 RPM
The crankshaft target synchronization gap is not identified AND the camshaft sensor signal is used to
calculate engine speed.
Battery Voltage ≤ 5 V
Fuel pressure sensor voltage < 0.25 V
Fuel pressure sensor voltage > 4.815 V
Mechanical Dump Valve is tripped

Malfunction Thresholds (all active):


Fuel pressure error > 100 bar

Cummins Inc. Revision Date: March 30, 2017 44


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

13. 1349.3-SE6690: Injector Metering Rail 2 Pressure Sensor Circuit -


Voltage Above Normal or Shorted to High Source
The ECM input voltage from the fuel pressure signal, for the second output of the fuel pressure sensor,
is greater than the specified upper limit.

Monitor Operation:
DTC 1349.3-SE6690
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Fuel Pressure Output 2 of the dual output fuel pressure sensor > 4.815 V (<-157.373 bar).

Cummins Inc. Revision Date: March 30, 2017 45


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

14. 1349.4-SE6691: Injector Metering Rail 2 Pressure Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The ECM input voltage from the fuel pressure signal, for the second output of the fuel pressure sensor,
is less than the specified lower limit.

Monitor Operation:
DTC 1349.4-SE6691
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Fuel Pressure Output 2 of the dual output fuel pressure sensor < 0.25 V (>2,124.87 bar)

Cummins Inc. Revision Date: March 30, 2017 46


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

15. 157.3-SE525: Injector Metering Rail 1 Pressure Sensor Circuit -


Voltage Above Normal or Shorted to High Source
Fuel pressure sensor input voltage is greater than the specified sensor operating range.

Monitor Operation:
DTC 157.3-SE525
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


fuel pressure sensor value > 4.815 V (2,157.373 bar).

Cummins Inc. Revision Date: March 30, 2017 47


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

16. 157.4-SE526: Injector Metering Rail 1 Pressure Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
Fuel pressure sensor input voltage is less than the specified sensor operating range.

Monitor Operation:
DTC 157.4-SE526
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Fuel pressure sensor value < 0.25 V (-124.87 bar)

Cummins Inc. Revision Date: March 30, 2017 48


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

17. 1347.2-SE915: Engine Fuel Pump Pressurizing Assembly 1 - Data


Erratic, Intermittent, or Incorrect
Monitor the fuel pressure to check the status of the Mechanical Dump Valve (MDV) and determine if an
intermittent open-circuit Inlet Metering Valve (IMV) was the reason for the MDV to open.

Monitor Operation:
DTC 1347.2-SE915
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1.5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine is running.
Peak rail pressure across one cam cycle > 1,900 bar OR (rail pressure at current crank tooth - rail
pressure at 2 firing intervals ago < RefTable25.1 bar) AND (rail pressure 2 firing intervals ago > 1,400
bar)
There is IMV open circuit error condition.
The number of failed MDV reset events in this driving cycle < 5
Time after ECM powerup ≥ 6 sec

Abort Conditions (any active):


157.3-SE525

Pause Conditions (any active):


Engine is stopped.
The number of failed MDV reset events in this driving cycle = 5
Time after ECM powerup < 6 sec

Malfunction Thresholds (all active):


(Rail pressure command ≥ 1,530 bar AND Peak rail pressure across one cam cycle < rail pressure
command – 200 bar) OR (Rail pressure command = 1,530 bar AND Peak rail pressure across one cam
cycle < 1,330 bar)
The number of failed MDV reset events in this driving cycle ≥ 2 counts

Cummins Inc. Revision Date: March 30, 2017 49


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

18. 1347.3-SE965: Engine Fuel Pump Pressurizing Assembly 1 Circuit -


Voltage Above Normal or Shorted to High Source
Detects an Inlet Metering Valve (IMV) circuit Open Load or Short to Battery.

Monitor Operation:
DTC 1347.3-SE965
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


IMV circuit open load or short to battery : IMV high side terminal voltage > 1.7V when high side
output is turned off
IMV circuit low side current low : IMV low side current < 0.301A when IMV current command > 0.6A

Cummins Inc. Revision Date: March 30, 2017 50


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

19. 633.31-SE518: Electronic Fuel Injection Control Valve Circuit -


Condition Exists
Detect the Inlet-metering valve (IMV) resistance error when measured IMV resistance is out of
calibrated range

Monitor Operation:
DTC 633.31-SE518
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


1347.3-SE965, 1347.4-SE966
Commanded IMV current ≥ 0.6 A
Time since Key ON ≥ 0.13 sec
(Ambient air temperature is >= -7 °C) OR (Engine is Warm)

Pause Conditions (any active):


1347.3-SE965, 1347.4-SE966
Commanded IMV current < 0.6 A
Time since Key ON < 0.13 sec
(Ambient air temperature is < -7 °C) AND (Engine is not Warm)

Malfunction Thresholds (all active):


(Measured IMV resistance <= 1.85 Ohm) OR (Measured IMV resistance >= 4.85 Ohm)

Cummins Inc. Revision Date: March 30, 2017 51


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

20. 1347.4-SE966: Engine Fuel Pump Pressurizing Assembly 1 Circuit -


Voltage Below Normal or Shorted to Low Source
Detects an Inlet Metering Valve (IMV) circuit Short to Ground.

Monitor Operation:
DTC 1347.4-SE966
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.2 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The PWM control high side driver is switched ON.
IMV high side voltage < (battery voltage -1) V.

Cummins Inc. Revision Date: March 30, 2017 52


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

21. 168.15-SE297: Battery 1 Voltage - Data Valid But Above Normal


Operating Range - Least Severe Level
Battery 1 Voltage - Data Valid But Above Normal Operating Range - Moderately Severe Level

Monitor Operation:
DTC 168.15-SE297
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine Is Running

Pause Conditions (any active):


Engine Is Not Running

Malfunction Thresholds (all active):


Battery Voltage > 17 V

Cummins Inc. Revision Date: March 30, 2017 53


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

22. 168.17-SE296: Battery 1 Voltage - Data Valid But Below Normal


Operating Range - Least Severe Level
Battery 1 Voltage - Data Valid But Below Normal Operating Range - Moderately Severe Level

Monitor Operation:
DTC 168.17-SE296
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine Is Running

Pause Conditions (any active):


Engine Is Not Running

Malfunction Thresholds (all active):


Battery Voltage < 9.999 V

Cummins Inc. Revision Date: March 30, 2017 54


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

23. 101.2-SE2086: Crankcase Pressure - Data Erratic, Intermittent, or


Incorrect
Crankcase Pressure is either In range High or In Range Low

Monitor Operation:
DTC 101.2-SE2086
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.02 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


101.3-SE1422, 101.4-SE1424
Engine Speed ≤ 0 RPM
Coolant Temperature is > 71.109 deg C for 300 seconds
Crankcase Pressure delta ≤ 0.02 kPa(gauge)

Abort Conditions (any active):


101.3-SE1422, 101.4-SE1424

Pause Conditions (any active):


Engine Speed > 0 RPM
Coolant Temperature has not been > 71.109 deg C for 300 seconds
Crankcase Pressure delta > 0.02 kPa(gauge)

Malfunction Thresholds (all active):


Crankcase Pressure > 0.5 kPa(gauge)
OR
Crankcase Pressure < -0.5 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 55


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

24. 1239.16-SE8484: Engine Fuel Leakage - Data Valid But Above


Normal Operating Range - Moderately Severe Level
Detect fuel system leakage that prevents Quantity and Timing Diagnostics from running.

Monitor Operation:
DTC 1239.16-SE8484
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Enable conditions for the tests run during motoring. (See RefCond139.16.)

Pause Conditions (any active):


NOT [ Enable conditions for the tests run during motoring. (See RefCond139.16.) ]

Malfunction Thresholds (all active):


Any of the following Malfunction Criteria is met:
Percentage of estimated leakage based on 20 test points during motoring ≥ 85 % for 2 times.
Percentage of motoring events with very high estimated leakage based on 20 test points ≥ 85 % for 2
times.

Cummins Inc. Revision Date: March 30, 2017 56


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

25. 157.15-SE8485: Injector Metering Rail 1 Pressure - Data Valid But


Above Normal Operating Range - Least Severe Level
Detect fuel system self-pumping that prevents Quantity and Timing Diagnostics from running.

Monitor Operation:
DTC 157.15-SE8485
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Enable conditions for the tests run during motoring. (See RefCond139.16.)

Pause Conditions (any active):


NOT [ Enable conditions for the tests run during motoring. (See RefCond139.16.) ]

Malfunction Thresholds (all active):


Percentage of estimated pumping based on 20 test points during motoring ≥ 85 % for 2 times.

Cummins Inc. Revision Date: March 30, 2017 57


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

26. 5285.18-SE5250: Engine Charge Air Cooler Efficiency - Data Valid


But Below Normal Operating Range - Moderately Severe Level
Charge Temperature is higher than specified temperature for a calibrated amount of time.

Monitor Operation:
DTC 5285.18-SE5250
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 15 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


4752.18-SE3565
105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-SE488
103.16-SE3641, 103.18-SE3642, 1172.3-SE486, 1172.4-SE484
Engine is not in RUN state
Compressor Outlet Temperature < 120 °C
Net Engine Torque < 815 Nm
Ambient Air Temperature < -6.67 °C

Malfunction Thresholds (all active):


Charge Temperature ≥ 95 °C

Cummins Inc. Revision Date: March 30, 2017 58


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

27. 101.2-SE3665: Crankcase Pressure - Data Erratic, Intermittent, or


Incorrect
Crankcase Pressure (CCP) sensor is stuck in range.

Monitor Operation:
DTC 101.2-SE3665
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 counts
MIL Activation Criteria 2 trips

Entry Conditions (all active):


101.2-SE2086
101.3-SE1422, 101.4-SE1424
Engine Speed > 0 RPM
Coolant Temperature is > 71.109 deg C FOR 300 sec.

Abort Conditions (any active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086
Engine Speed = 0 RPM

Pause Conditions (any active):


Coolant Temperature is < 71.109 deg C

Malfunction Thresholds (all active):


Maximum Crankcase Pressure - Minimum Crankcase Pressure < 0.169 kPa(gauge)
High Power Condition and Low Power Condition have been met.
Where: High Power Condition is defined as ((Engine Torque ≥ 182 Nm AND Engine Speed ≥ 1,500 RPM
AND Boost Pressure ≥ 80 kPa (Gauge)) FOR ≥ 10 sec
Low Power Condition is defined as ((Engine Torque ≤ 78 Nm AND Engine Speed ≤ 850 RPM AND Boost
Pressure ≤ 28.34 kPa (Gauge)) FOR ≥ 10 sec

Cummins Inc. Revision Date: March 30, 2017 59


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

28. 101.15-SE5592: Crankcase Pressure - Data Valid But Above Normal


Operating Range - Least Severe Level
High Crankcase Pressure (CCP) while idling.

Monitor Operation:
DTC 101.15-SE5592
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3,600 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086
Engine speed must be >= 400 RPM FOR 10 counts.
Engine Speed must be <= 1,050 RPM FOR 10 counts.
( No Active Ambient Air Temperature System Errors (See RefCond148.4.) OR ((Coolant temperature >
71.109 degC FOR 300 sec) AND None active: [110.3-SE75, 110.4-SE76]) )

Abort Conditions (any active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086

Pause Conditions (any active):


Engine Speed < 400 RPM
Engine Speed > 1,050 RPM
Any Active Air Temperature System Errors (See RefCond149.5.) AND (Coolant temperature ≤ 71.109
degC OR 110.3-SE75 is Active OR 110.4-SE76 is Active)

Malfunction Thresholds (all active):


Crankcase Pressure ≥ RefTable198.4 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 60


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

29. 4752.18-SE3565: Engine Exhaust Gas Recirculation Cooler


Efficiency - Data Valid But Below Normal Operating Range -
Moderately Severe Level
EGR cooler failed to provide enough cooling.

Monitor Operation:
DTC 4752.18-SE3565
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 140 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.3-SE487, 105.4-SE488, 1209.2-
SE3922, 1209.2-SE3924, 1209.3-SE493, 1209.4-SE494, 411.3-SE485, 411.4-SE483, 412.2-SE3872,
412.2-SE3876, 412.2-SE3877, 412.2-SE3878
102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.3-SE487, 105.4-SE488, 1209.2-
SE3922, 1209.2-SE3924, 1209.3-SE493, 1209.4-SE494
412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
110.2-SE3668, 110.2-SE3669, 110.3-SE75, 110.4-SE76
27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
EGR flow < 1.5 kg/min
Exhaust temperature minus coolant temperature < 370 °C
Aftertreatment operation mode is in a mode other than NORMAL

Malfunction Thresholds (all active):


Average of (EGR Orifice Temperature - RefTable189.1) over a 140 second period is ever ≥ 1.179 DegC
Diagnostic Tolerance = 0 DegC (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 61


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

30. 102.20-SE3651: Intake Manifold 1 Pressure - Data Not Rational -


Drifted High
Charge Pressure Sensor reading is In Range High.

Monitor Operation:
DTC 102.20-SE3651
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 45 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


EGR Off Engine Protection is active and Number of OBD Operating Cycle Increases
Key Switch Detect Increase

Pause Conditions (any active):


3464.3-SE12370, 3464.3-SE12372, 3464.4-SE12371, 51.2-SE4014, 51.2-SE4015, 51.3-SE3530, 51.4-
SE3529
102.3-SE489, 102.4-SE490
102.2-SE4439
102.21-SE3652, 103.16-SE3641, 103.18-SE3642, 105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-
SE488, 1172.2-SE4190, 1172.2-SE4746, 1172.3-SE486, 1172.4-SE484, 3226.4-SE5987, 3226.4-SE5990,
3226.9-SE2488, 3228.2-SE5988
Engine is not in Run State.
EGR Off Engine Protection is active
Intake Throttle Position > 15 %

Malfunction Thresholds (all active):


Average of (Charge Pressure - Estimated Charge Pressure) over a 45 second period is ever ≥ 60 kPa
Diagnostic Tolerance = RefTable90.3 kPa
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 62


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

31. 102.21-SE3652: Intake Manifold 1 Pressure - Data Not Rational -


Drifted Low
Charge Pressure Sensor reading is In Range Low.

Monitor Operation:
DTC 102.21-SE3652
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 45 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


EGR Off Engine Protection is active and Number of OBD Operating Cycle Increases
Key Switch Detect Increase

Pause Conditions (any active):


102.2-SE4439
3464.3-SE12370, 3464.3-SE12372, 3464.4-SE12371, 51.2-SE4014, 51.2-SE4015, 51.3-SE3530, 51.4-
SE3529
102.3-SE489, 102.4-SE490
102.20-SE3651, 103.16-SE3641, 103.18-SE3642, 105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-
SE488, 1172.2-SE4190, 1172.2-SE4746, 1172.3-SE486, 1172.4-SE484, 3226.4-SE5987, 3226.4-SE5990,
3226.9-SE2488, 3228.2-SE5988
Engine is not in Run State.
EGR Off Engine Protection is active
Intake Throttle Position > 15 %

Malfunction Thresholds (all active):


Average of (Estimated Charge Pressure - Charge Pressure) over a 45 second period is ever ≥ 60 kPa
Diagnostic Tolerance = RefTable90.3 kPa
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 63


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

32. 102.2-SE4439: Intake Manifold 1 Pressure - Data Erratic,


Intermittent, or Incorrect
Charge Pressure Sensor reading is erratic, intermittent or incorrect at keyoff.

Monitor Operation:
DTC 102.2-SE4439
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine is in stopped state
The time since Key Switch is turned OFF ≥ 52 sec

Abort Conditions (any active):


102.3-SE489, 102.4-SE490
Coolant Temperature ≤ 70 °C

Malfunction Thresholds (all active):


|Charge Pressure - the most accurate pressure sensor from the remaining pressure sensor| > (11.84
kPa(absolute) + the tolerance of the most accurate pressure sensor from the remaining pressure
sensors)
|Charge Pressure - the second most accurate pressure sensor from the remaining pressure sensor| >
(11.84 kPa(absolute) + the tolerance of the second most accurate pressure sensor from the remaining
pressure sensors)
| the most accurate sensor from the remaining pressure sensors - the second most accurate sensor
from the remaining pressure sensors | < (the tolerance of the most accurate sensor from the
remaining pressure sensors + the tolerance of the second most accurate sensor from the remaining
pressure sensors)
The tolerance of the remaining pressure sensors are:
Exhaust Pressure sensor tolerance = 27.69 kPa(absolute)
Compressor Inlet Pressure sensor tolerance = 3.19 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 64


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

33. 102.3-SE489: Intake Manifold 1 Pressure Sensor Circuit - Voltage


Above Normal or Shorted to High Source
Charge Pressure sensor reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 102.3-SE489
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Charge Pressure sensor value > 4.75V (349.98 kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 65


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

34. 102.4-SE490: Intake Manifold 1 Pressure Sensor Circuit - Voltage


Below Normal or Shorted to Low Source
Charge Pressure sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 102.4-SE490
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Charge Pressure sensor value < 0.25V (44.82 kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 66


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

35. 105.2-SE4070: Intake Manifold 1 Temperature - Data Erratic,


Intermittent, or Incorrect
Charge Temperature reading is In Range Low.

Monitor Operation:
DTC 105.2-SE4070
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 60 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


105.3-SE487, 105.4-SE488
105.2-SE3793
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.3-
SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494,
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-SE485, 411.4-
SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1172.2-SE4190, 1172.2-SE4746, 1172.3-SE486, 1172.4-SE484
102.20-SE3651, 102.21-SE3652, 103.16-SE3641, 103.18-SE3642, 1172.2-SE4190, 1172.2-SE4746,
1172.3-SE486, 1172.4-SE484, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-
SE8366
Fresh Air Flow ≤ 8 kg/min
Ambient Air Temperature ≤ -6.67 °C
Compressor Inlet Temperature ≥ 50 °C
Compressor Outlet Temperature - Compressor Inlet Temperature < 40 °C
|Compressor Inlet Temperature - Ambient Air Temperature| > 12 °C
PTO is active
Remote Throttle is active
EGR Off Engine Protection from aftertreatment component is active.
EGR Off Engine Protection from air handling component is active.
Engine is not in Run state OR Engine has been in Run state for < 120 s
Grid Heater State is not in OFF state OR Grid Heater State has been in OFF state for < 120 s

Malfunction Thresholds (all active):


Average of (Estimated Charge Temperature - Charge Temperature) over a 60 second period is ever ≥
36 degC Diagnostic Tolerance = 0 degC (Please refer to the CUSUM Supplement in Section C for
further details.)

Cummins Inc. Revision Date: March 30, 2017 67


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

36. 105.2-SE3793: Intake Manifold 1 Temperature - Data Erratic,


Intermittent, or Incorrect
Charge Temperature sensor reading is erratic, intermittent or incorrect.

Monitor Operation:
DTC 105.2-SE3793
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine off time ≥ 480 min
The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Abort Conditions (any active):


105.3-SE487, 105.4-SE488
251.10-SE4759
251.10-SE4760

Malfunction Thresholds (all active):


| Charge Temperature sensor - the most accurate sensor from the remaining temperature sensors | >
(21 degC + the tolerance of the most accurate sensor from the remaining temperature sensors)
| Charge Temperature sensor - the second most accurate sensor from the remaining temperature
sensors | > (21 degC + the tolerance of the second most accurate sensor from the remaining
temperature sensors)
| the most accurate sensor from the remaining temperature sensors - the second most accurate
sensor from the remaining temperature sensors | < (the tolerance of the most accurate sensor from
the remaining temperature sensors + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
The tolerance of the remaining temperature sensors are:
Compressor Inlet Temperature sensor tolerance = 40 °C
Air Temperature sensor tolerance = 35 °C
Coolant Temperature sensor tolerance = 20 °C
ECM Internal Temperature sensor tolerance = 210 °C
EGR Orifice Temperature sensor tolerance = 25 °C

Cummins Inc. Revision Date: March 30, 2017 68


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

37. 105.3-SE487: Intake Manifold 1 Temperature Sensor Circuit -


Voltage Above Normal or Shorted to High Source
Charge Temperature sensor reading greater than specified operating range for a calibrated amount of
time.

Monitor Operation:
DTC 105.3-SE487
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Charge Temperature sensor value > 4.883V (< -40 degC)

Cummins Inc. Revision Date: March 30, 2017 69


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

38. 105.4-SE488: Intake Manifold 1 Temperature Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
Charge Temperature sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 105.4-SE488
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Charge Temperature sensor value < 0.057V (> 139.617 degC)

Cummins Inc. Revision Date: March 30, 2017 70


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

39. 1176.2-SE8698: Turbocharger 1 Compressor Intake Pressure - Data


Erratic, Intermittent, or Incorrect
Compressor Inlet Pressure reading is In Range High

Monitor Operation:
DTC 1176.2-SE8698
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


1176.2-SE8802
1176.3-SE8365, 1176.4-SE8366
Engine is not in Run State.

Malfunction Thresholds (all active):


Average of (Compressor Inlet Pressure - Estimated Compressor Inlet Pressure) over a 30 second
period is ever ≥ 26.84 kPa Diagnostic Tolerance = 26.74 kPa (Please refer to the CUSUM Supplement
in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 71


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

40. 1176.2-SE8699: Turbocharger 1 Compressor Intake Pressure - Data


Erratic, Intermittent, or Incorrect
Compressor Inlet Pressure reading is In Range Low

Monitor Operation:
DTC 1176.2-SE8699
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


1176.2-SE8802
1176.3-SE8365, 1176.4-SE8366
Engine is not in Run State.

Malfunction Thresholds (all active):


Average of (Estimated Compressor Inlet Pressure - Compressor Inlet Pressure) over a 30 second
period is ever ≥ 26.84 kPa Diagnostic Tolerance = 26.74 kPa (Please refer to the CUSUM Supplement
in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 72


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

41. 1176.2-SE8802: Turbocharger 1 Compressor Intake Pressure - Data


Erratic, Intermittent, or Incorrect
Compressor Inlet Pressure Sensor reading is erratic, intermittent or incorrect at keyoff.

Monitor Operation:
DTC 1176.2-SE8802
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine is in stopped state
The time since Key Switch is turned OFF ≥ 52 sec

Abort Conditions (any active):


1176.3-SE8365, 1176.4-SE8366
Coolant Temperature ≤ 70 °C

Malfunction Thresholds (all active):


(|Compressor Inlet Pressure - the most accurate pressure sensor from the remaining pressure
sensor| > 3.19 kPa(absolute) + the tolerance of the most accurate pressure sensor from the
remaining pressure sensors
|Compressor Inlet Pressure - the second most accurate pressure sensor from the remaining pressure
sensor| > 3.19 kPa(absolute) + the tolerance of the second most accurate pressure sensor from the
remaining pressure sensors
| the most accurate sensor from the remaining pressure sensors - the second most accurate sensor
from the remaining pressure sensors | < the tolerance of the most accurate sensor from the
remaining pressure sensors + the tolerance of the second most accurate sensor from the remaining
pressure sensors)
The tolerance of the remaining pressure sensors are:
Exhaust Pressure sensor tolerance = 27.69 kPa(absolute)
Charge Pressure sensor tolerance = 11.84 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 73


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

42. 1176.3-SE8365: Turbocharger 1 Compressor Intake Pressure


Circuit - Voltage Above Normal or Shorted to High Source
Compressor Inlet Pressure sensor reading greater than specified operating range for a calibrated
amount of time.

Monitor Operation:
DTC 1176.3-SE8365
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Compressor Inlet Pressure sensor value > 4.75 V (110.32 kPa (absolute))

Cummins Inc. Revision Date: March 30, 2017 74


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

43. 1176.4-SE8366: Turbocharger 1 Compressor Intake Pressure


Circuit - Voltage Below Normal or Shorted to Low Source
Compressor Inlet Pressure sensor reading less than specified operating range for a calibrated amount of
time.

Monitor Operation:
DTC 1176.4-SE8366
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Compressor Inlet Pressure sensor value < 0.25 V (44.82 kPa (absolute))

Cummins Inc. Revision Date: March 30, 2017 75


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

44. 1172.2-SE4190: Turbocharger 1 Compressor Intake Temperature -


Data Erratic, Intermittent, or Incorrect
Compressor Inlet Temperature reading is In Range High

Monitor Operation:
DTC 1172.2-SE4190
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 150 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine has been in Run state for >= 120 s

Pause Conditions (any active):


1172.2-SE4746
1172.3-SE486, 1172.4-SE484

Malfunction Thresholds (all active):


Average of (Compressor Inlet Temperature - Estimated Compressor Inlet Temperature) over a 150
second period is ever ≥ 70.5 degC Diagnostic Tolerance = 68.5 degC (Please refer to the CUSUM
Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 76


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

45. 1172.2-SE4746: Turbocharger 1 Compressor Intake Temperature -


Data Erratic, Intermittent, or Incorrect
Compressor Inlet Temperature sensor reading is erratic, intermittent or incorrect.

Monitor Operation:
DTC 1172.2-SE4746
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine off time ≥ 480 min
The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Abort Conditions (any active):


1172.3-SE486, 1172.4-SE484
251.10-SE4759
251.10-SE4760

Malfunction Thresholds (all active):


| Compressor Inlet Temperature sensor - the most accurate sensor from the remaining temperature
sensors | > (40 degC + the tolerance of the most accurate sensor from the remaining temperature
sensors)
| Compressor Inlet Temperature sensor - the second most accurate sensor from the remaining
temperature sensors | > (40 degC + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
| the most accurate sensor from the remaining temperature sensors - the second most accurate
sensor from the remaining temperature sensors | < (the tolerance of the most accurate sensor from
the remaining temperature sensors + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
The tolerance of the remaining temperature sensors are:
Air Temperature sensor tolerance = 35 °C
Charge Temperature sensor tolerance = 21 °C
Coolant Temperature sensor tolerance = 20 °C
ECM Internal Temperature sensor tolerance = 210 °C
EGR Orifice Temperature sensor tolerance = 25 °C

Cummins Inc. Revision Date: March 30, 2017 77


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

46. 1172.3-SE486: Turbocharger 1 Compressor Intake Temperature


Circuit - Voltage Above Normal or Shorted to High Source
Compressor Inlet Temperature sensor reading greater than specified operating range for a calibrated
amount of time.

Monitor Operation:
DTC 1172.3-SE486
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Compressor Inlet Temperature sensor value > 4.979V (< -40 degC)

Cummins Inc. Revision Date: March 30, 2017 78


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

47. 1172.4-SE484: Turbocharger 1 Compressor Intake Temperature


Circuit - Voltage Below Normal or Shorted to Low Source
Compressor Inlet Temperature sensor reading less than specified operating range for a calibrated
amount of time.

Monitor Operation:
DTC 1172.4-SE484
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Compressor Inlet Temperature sensor value < 0.098V (> 119.489 degC)

Cummins Inc. Revision Date: March 30, 2017 79


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

48. 6303.3-SE7984: Engine Coolant Level 2 Sensor Circuit - Voltage


Above Normal or Shorted to High Source
The auxiliary coolant level sensor input voltage is higher than expected from a functioning sensor.

Monitor Operation:
DTC 6303.3-SE7984
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 500 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Auxiliary Coolant Level Sensor input voltage ≥ 4.273 V
Note: Auxiliary Coolant Level Sensor is a switched input. The voltage threshold in this malfunction
criteria represents a value above that which would otherwise be possible with a functioning switch.

Cummins Inc. Revision Date: March 30, 2017 80


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

49. 6303.4-SE7985: Engine Coolant Level 2 Sensor Circuit - Voltage


Below Normal or Shorted to Low Source
The auxiliary coolant level sensor input voltage is lower than expected from a functioning sensor.

Monitor Operation:
DTC 6303.4-SE7985
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 500 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Auxiliary Coolant Level Sensor input voltage ≤ 0.305 V
Note: Auxiliary Coolant Level Sensor is a switched input. The voltage threshold in this malfunction
criteria represents a value below that which would otherwise be possible with a functioning switch.

Cummins Inc. Revision Date: March 30, 2017 81


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

50. 111.3-SE572: Coolant Level Sensor 1 Circuit - Voltage Above


Normal or Shorted to High Source
Coolant Level Sensor Circuit has its voltage above normal, or shorted to a high source

Monitor Operation:
DTC 111.3-SE572
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Coolant Level Sensor Value > 4.418 V

Cummins Inc. Revision Date: March 30, 2017 82


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

51. 111.4-SE283: Coolant Level Sensor 1 Circuit - Voltage Below


Normal or Shorted to Low Source
Coolant Level Sensor Circuit has its voltage below normal, or is shorted to a low source.

Monitor Operation:
DTC 111.4-SE283
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Coolant Level Sensor Value < 0.577 V

Cummins Inc. Revision Date: March 30, 2017 83


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

52. 111.18-SE3993: Coolant Level - Data Valid But Below Normal


Operating Range - Moderately Severe Level
Indicates to OBD Fault Handler that Coolant Level Severely Low has been detected.

Monitor Operation:
DTC 111.18-SE3993
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Engine Speed > 0 RPM

Abort Conditions (any active):

Pause Conditions (any active):


111.3-SE572, 111.4-SE283

Malfunction Thresholds (all active):


Coolant Level Sensor Volts ≥ 3 V

Cummins Inc. Revision Date: March 30, 2017 84


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

53. 110.15-SE80: Engine Coolant Temperature - Data Valid But Above


Normal Operating Range - Least Severe Level
Data from the Coolant Temperature sensor is valid but above normal operating range

Monitor Operation:
DTC 110.15-SE80
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine Speed ≥ 400 RPM
Time after the engine has started ≥ 0 sec

Pause Conditions (any active):


110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
Engine Speed < 400 RPM

Malfunction Thresholds (all active):


Coolant Temperature ≥ 107.203 °C

Cummins Inc. Revision Date: March 30, 2017 85


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

54. 110.3-SE75: Engine Coolant Temperature 1 Sensor Circuit - Voltage


Above Normal or Shorted to High Source
Coolant Temperature sensor circuit has its voltage above normal, or shorted to a high source

Monitor Operation:
DTC 110.3-SE75
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Coolant Temperature Sensor Value > 4.956 V (<-40 Deg C)

Cummins Inc. Revision Date: March 30, 2017 86


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

55. 110.16-SE2157: Engine Coolant Temperature - Data Valid But


Above Normal Operating Range - Moderately Severe Level
The engine's Coolant Temperature data is above a calibratable warning limit.

Monitor Operation:
DTC 110.16-SE2157
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine Speed ≥ 400 RPM
Time after the engine has started ≥ 0 sec

Pause Conditions (any active):


110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
Engine Speed < 400 RPM

Malfunction Thresholds (all active):


Coolant Temperature ≥ 107.203 °C

Cummins Inc. Revision Date: March 30, 2017 87


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

56. 110.4-SE76: Engine Coolant Temperature 1 Sensor Circuit - Voltage


Below Normal or Shorted to Low Source
Coolant Temperature Circuit has its voltage below normal, or is shorted to a low source.

Monitor Operation:
DTC 110.4-SE76
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Coolant Temperature Sensor Value < 0.108 V (>140 Deg C)

Cummins Inc. Revision Date: March 30, 2017 88


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

57. 110.0-SE81: Engine Coolant Temperature - Data Valid But Above


Normal Operating Range - Most Severe Level
Data from the Coolant Temperature sensor is valid but above normal operating range.

Monitor Operation:
DTC 110.0-SE81
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine Speed ≥ 400 RPM
Time after the engine has started ≥ 0 sec

Pause Conditions (any active):


110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
Engine Speed < 400 RPM

Malfunction Thresholds (all active):


Coolant Temperature ≥ 112.797 °C

Cummins Inc. Revision Date: March 30, 2017 89


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

58. 110.2-SE3668: Engine Coolant Temperature - Data Erratic,


Intermittent, or Incorrect
Coolant Temperature In Range Low Error

Monitor Operation:
DTC 110.2-SE3668
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Maximum Coolant Temperature this trip ≥ 71.109 °C
Engine Is Running

Abort Conditions (any active):


Engine is not Running

Pause Conditions (any active):


110.4-SE76
110.3-SE75
110.2-SE3805
110.2-SE3669
Engine At Idle AND Vehicle Speed <= 0 mph
Engine Speed ≤ 575 RPM
Ambient Air Temperature < -6.664 °C

Malfunction Thresholds (all active):


Coolant Temperature < 50 °C

Cummins Inc. Revision Date: March 30, 2017 90


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

59. 110.2-SE3669: Engine Coolant Temperature - Data Erratic,


Intermittent, or Incorrect
Coolant Temperature Stuck In Range Error

Monitor Operation:
DTC 110.2-SE3669
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine Is Running

Abort Conditions (any active):


Engine is not Running

Pause Conditions (any active):


110.4-SE76
110.3-SE75
110.2-SE3805
110.2-SE3668

Malfunction Thresholds (all active):


Over 300 samples; Maximum Coolant Temperature – Minimum Coolant Temperature < 0.5 DegC
Where: Samples are taken when either: ‘High': Net Engine Torque > 450 Nm ‘Low’: Net Engine Torque
< 250 Nm

Cummins Inc. Revision Date: March 30, 2017 91


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

60. 110.2-SE3805: Engine Coolant Temperature - Data Erratic,


Intermittent, or Incorrect
Coolant Temperature sensor reading is erratic, intermittent or incorrect.

Monitor Operation:
DTC 110.2-SE3805
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine off time ≥ 480 min
The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Abort Conditions (any active):


110.3-SE75, 110.4-SE76
251.10-SE4759
251.10-SE4760

Malfunction Thresholds (all active):


| Coolant Temperature sensor - the most accurate sensor from the remaining temperature sensors |
> (20 degC + the tolerance of the most accurate sensor from the remaining temperature sensors)
| Coolant Temperature sensor - the second most accurate sensor from the remaining temperature
sensors | > (20 degC + the tolerance of the second most accurate sensor from the remaining
temperature sensors)
| the most accurate sensor from the remaining temperature sensors - the second most accurate
sensor from the remaining temperature sensors | < (the tolerance of the most accurate sensor from
the remaining temperature sensors + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
The tolerance of the remaining temperature sensors are:
Compressor Inlet Temperature sensor tolerance = 40 °C
Charge Temperature sensor tolerance = 21 °C
Air Temperature sensor tolerance = 35 °C
ECM Internal Temperature sensor tolerance = 210 °C
EGR Orifice Temperature sensor tolerance = 25 °C

Cummins Inc. Revision Date: March 30, 2017 92


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

61. 101.15-SE2018: Crankcase Pressure - Data Valid But Above Normal


Operating Range - Least Severe Level
Crankcase Pressure - High (moderate severity)

Monitor Operation:
DTC 101.15-SE2018
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086, 101.2-SE3665
( No Active Ambient Air Temperature System Errors (See RefCond148.4.) OR ((Coolant temperature >
71.109 degC FOR 300 sec) AND None active: [110.3-SE75, 110.4-SE76]) OR Engine Speed > 0 RPM )

Abort Conditions (any active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086, 101.2-SE3665
Engine Speed = 0 RPM

Pause Conditions (any active):


Any Active Air Temperature System Errors (See RefCond149.5.) AND (Coolant temperature ≤ 71.109
degC OR 110.3-SE75 is Active OR 110.4-SE76 is Active) AND Engine Speed > 0 RPM

Malfunction Thresholds (all active):


Crankcase Pressure ≥ RefTable66.4 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 93


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

62. 101.16-SE2020: Crankcase Pressure - Data Valid But Above Normal


Operating Range - Moderately Severe Level
Crankcase Pressure - High (critical severity)

Monitor Operation:
DTC 101.16-SE2020
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086, 101.2-SE3665
( No Active Ambient Air Temperature System Errors (See RefCond148.4.) OR ((Coolant temperature >
71.109 degC FOR 300 sec) AND None active: [110.3-SE75, 110.4-SE76]) OR Engine Speed > 400 RPM )

Abort Conditions (any active):


101.3-SE1422, 101.4-SE1424
101.2-SE2086, 101.2-SE3665
Engine Speed < 400 RPM

Pause Conditions (any active):


Any Active Air Temperature System Errors (See RefCond149.5.) AND (Coolant temperature ≤ 71.109
degC OR 110.3-SE75 is Active OR 110.4-SE76 is Active) AND Engine Speed > 400 RPM

Malfunction Thresholds (all active):


Crankcase Pressure ≥ RefTable117.5 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 94


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

63. 101.3-SE1422: Crankcase Pressure Circuit - Voltage Above Normal


or Shorted to High Source
Crankcase Pressure Out Of Range High

Monitor Operation:
DTC 101.3-SE1422
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Crankcase Pressure Sensor Value > 4.746 V (6.89 kPa (gauge))

Cummins Inc. Revision Date: March 30, 2017 95


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

64. 101.4-SE1424: Crankcase Pressure Circuit - Voltage Below Normal


or Shorted to Low Source
Crankcase Pressure Out Of Range Low

Monitor Operation:
DTC 101.4-SE1424
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Crankcase Pressure Sensor Value < 0.254 V (-2.49 kPa (gauge))

Cummins Inc. Revision Date: March 30, 2017 96


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

65. 1323.31-SE2344: Engine Misfire Cylinder 1 - Condition Exists


Cylinder 1 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1323.31-SE2344
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 97


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 98


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

66. 1324.31-SE2346: Engine Misfire Cylinder 2 - Condition Exists


Cylinder 2 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1324.31-SE2346
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 99


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 100


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

67. 1325.31-SE2347: Engine Misfire Cylinder 3 - Condition Exists


Cylinder 3 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1325.31-SE2347
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 101


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 102


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

68. 1326.31-SE2345: Engine Misfire Cylinder 4 - Condition Exists


Cylinder 4 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1326.31-SE2345
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 103


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 104


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

69. 1327.31-SE2348: Engine Misfire Cylinder 5 - Condition Exists


Cylinder 5 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1327.31-SE2348
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 105


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 106


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

70. 1328.31-SE2349: Engine Misfire Cylinder 6 - Condition Exists


Cylinder 6 misfire is detected when an increase in its commanded fueling does not yield an expected
increase in torque.

Monitor Operation:
DTC 1328.31-SE2349
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is not in WARM State.

Cummins Inc. Revision Date: March 30, 2017 107


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not at IDLE State.


OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Normalized crankshaft acceleration corresponding to the power cycle of the test cylinder <=
RefTable67.3 for 5 tests.

Cummins Inc. Revision Date: March 30, 2017 108


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

71. 3242.16-SE3070: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Aftertreatment DOC delta gas temperature is continuously above a high threshold for a calibrated
period of time while active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 3242.16-SE3070
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 55 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
(Engine running condition (See RefCond368.1.) AND NOT[Dosing check conditions for Non-Regen
severe temperature faults. (See RefCond468.1.)])for time ≥ 540 sec

Pause Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC inlet temperature ≤ 200 °C
DOC outlet temperature ≤ 200 °C

Malfunction Thresholds (all active):


DOC outlet temperature - DOC inlet temperature > 400 °C

Cummins Inc. Revision Date: March 30, 2017 109


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

72. 4765.2-SE13176: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at DOC Inlet is in-range low.

Monitor Operation:
DTC 4765.2-SE13176
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
Engine is not in motoring condition for 300 sec
Engine speed > 600 rpm for 300 sec.
(Ambient air temperature ≥ 0 degC AND Ambient Air Temperature status is valid.) OR (( ( (Ambient air
temperature < 0 degC and Ambient Air Temperature status is valid) OR Ambient air temperature
status is not valid) AND Engine speed is > 600rpm for 300sec AND Exhaust flow rate is ≥ 100g/sec for
300sec) for 30sec.)
Exhaust flow rate ≥ 100 g/sec for 300 sec.
NOT [DOC Inlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond381.2.)]
NOT[DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond66.2.)]
NOT[DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See
RefCond382.2.)]

Abort Conditions (any active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
DOC Inlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond381.2.)

Pause Conditions (any active):


Engine is in motoring condition for 30 sec
Engine speed ≤ 600 rpm for 30 sec
Exhaust flow rate < 100 g/sec for 30 sec.

Cummins Inc. Revision Date: March 30, 2017 110


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


Average DOC Inlet temperature over 10 seconds < 70 °C

Cummins Inc. Revision Date: March 30, 2017 111


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

73. 4765.2-SE2858: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Aftertreatment DOC intake gas temperature is in-range but not rational.

Monitor Operation:
DTC 4765.2-SE2858
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-
SE13176
5742.9-SE12508
Engine running condition (See RefCond368.1.)
Elapsed time since last active regeneration ≥ 300 sec
115 g/sec ≤ Exhaust flow
103 degC ≤ (DOC intake or DOC outlet or DPF outlet) gas temperature ≤ 500 degC
300 sec have elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
was active

Abort Conditions (any active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878

Cummins Inc. Revision Date: March 30, 2017 112


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-


SE13176
5742.9-SE12508
Regeneration is Active
Elapsed time since last active regeneration < 300 sec

Pause Conditions (any active):


OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond66.2.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond64.2.)
DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


(Average of (DOC inlet - DOC outlet) > 65 degC) OR (Average of (DOC inlet - DOC outlet) < -70 degC)
-70 degC < average of (DOC outlet - DPF outlet) < 85 degC

Cummins Inc. Revision Date: March 30, 2017 113


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

74. 4765.2-SE13173: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at DOC Inlet is in-range high.

Monitor Operation:
DTC 4765.2-SE13173
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine Speed ≤ 600 RPM
NOT [DOC Inlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond381.2.)]
Module-off time > 28,800 sec
Module-off time status is valid
Key switch is ON and diagnostic has not made a decision in current key cycle.

Abort Conditions (any active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine speed > 600 RPM for 10 sec.
DOC Inlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond381.2.)

Pause Conditions (any active):


DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond66.2.)
Module-off time ≤ 28,800 sec
Module-off time status is not valid

Malfunction Thresholds (all active):


Average DOC Inlet temperature over 2 seconds ≥ 70 °C

Cummins Inc. Revision Date: March 30, 2017 114


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

75. 4765.16-SE3068: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Aftertreatment DOC inlet gas temperature is above a high threshold for a calibrated period of time while
active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 4765.16-SE3068
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 65 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


(Engine running condition (See RefCond368.1.) AND NOT[Dosing check conditions for Non-Regen
severe temperature faults. (See RefCond468.1.)])for time ≥ 540 sec

Pause Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)

Malfunction Thresholds (all active):


DOC inlet temperature > 745 °C

Cummins Inc. Revision Date: March 30, 2017 115


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

76. 5298.18-SE4719: Aftertreatment 1 Diesel Oxidation Catalyst


Conversion Efficiency - Data Valid But Below Normal Operating
Range - Moderately Severe Level
Decrease in the NMHC conversion capability of the DOC that would cause tailpipe out NMHC emissions
to exceed the applicable OBD threshold.

Monitor Operation:
DTC 5298.18-SE4719
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 320 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Conditions that enable the calculation of conversion efficiency of an oxidation catalyst. (See
RefCond152.51.)

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508

Pause Conditions (any active):


Conditions that pause the calculation of conversion efficiency of an oxidation catalyst. (See
RefCond154.22.)

Malfunction Thresholds (all active):


Filtered value of Hydrocarbon dosing efficiency < 52 %, where Hydrocarbon dosing efficiency is
defined as DOC Heat / DOC Dosing Heat

Cummins Inc. Revision Date: March 30, 2017 116


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 117


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

77. 4796.31-SE1757: Aftertreatment 1 Diesel Oxidation Catalyst


Missing - Condition Exists
Aftertreatment DOC has been detected as missing.

Monitor Operation:
DTC 4796.31-SE1757
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
Exhaust flow rate of change < 200 g/sec2
50 g/sec < Exhaust flow rate < 375 g/sec
DOC Inlet temperature ≥ 250 °C
DOC Inlet temperature ≤ 425 °C
DPF Inlet temperature ≥ 250 °C
Rate of active/intrusive injection of hydrocarbons in exhaust > 0.12 g/sec
Rate of change of active/intrusive injection of hydrocarbons in exhaust < 3 g/sec2
Elapsed time with all enable conditions met ≥ 65 sec
Soot Filter is actively requesting DESOOT mode.

Abort Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,

Cummins Inc. Revision Date: March 30, 2017 118


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,


412.2-SE3878
Exhaust flow rate < 50 g/sec OR exhaust flow rate > 375 g/sec
Exhaust flow rate of change > 200 g/sec2
DOC Inlet temperature < 250 °C
DOC Inlet temperature > 425 °C
DPF Inlet Temperature < 250 °C
Rate of change of active/intrusive injection of hydrocarbons in exhaust > 3 g/sec2
Rate of active/intrusive injection of hydrocarbons in exhaust < 0.12 g/sec

Malfunction Thresholds (all active):


DPF Intake temperature - DOC Intake temperature < 30 °C

Cummins Inc. Revision Date: March 30, 2017 119


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

78. 3242.2-SE13177: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at DOC Outlet is in-range low.

Monitor Operation:
DTC 3242.2-SE13177
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
Engine is not in motoring condition for 300sec
Engine speed > 600 rpm for 300 sec.
(Ambient air temperature > 0 degC AND Ambient Air Temperature status is valid.) OR (( ( (Ambient air
temperature < 0 degC and Ambient Air Temperature status is valid) OR Ambient air temperature
status is not valid) AND Engine speed is > 600rpm for 300sec AND Exhaust flow rate is >= 100g/sec for
300sec) for 30sec)
Exhaust flow rate >= 100 g/sec for 300 sec.
NOT [DOC Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond383.2.)]
NOT[DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)]

Abort Conditions (any active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
DOC Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond383.2.)

Pause Conditions (any active):


Engine is in motoring condition for 30sec
Engine speed ≤ 600 rpm for 30 sec
Exhaust flow rate < 100 g/sec for 30 sec.

Malfunction Thresholds (all active):


Average DOC Outlet temperature over 10 seconds < 70 °C

Cummins Inc. Revision Date: March 30, 2017 120


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 121


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

79. 3242.2-SE2844: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Aftertreatment DPF intake gas temperature is in-range but not rational.

Monitor Operation:
DTC 3242.2-SE2844
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-
SE13176
5742.9-SE12508
Engine running condition (See RefCond368.1.)
Elapsed time since last active regeneration ≥ 300 sec
115 g/sec ≤ Exhaust flow
103 degC ≤ (DOC intake or DOC outlet or DPF outlet) gas temperature ≤ 500 degC
300 seconds have elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728

Cummins Inc. Revision Date: March 30, 2017 122


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-


SE13176
5742.9-SE12508
Regeneration is Active
Elapsed time since last active regeneration < 300 sec

Pause Conditions (any active):


OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond66.2.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond64.2.)
DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


(Average of (DOC inlet - DOC outlet) > 65 degC) OR (Average of (DOC inlet - DOC outlet) < -70 degC)
(Average of (DOC outlet - DPF outlet) > 85 degC) OR (Average of (DOC outlet - DPF outlet) < -70 degC)

Cummins Inc. Revision Date: March 30, 2017 123


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

80. 3242.2-SE13174: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at DOC Outlet is in-range high.

Monitor Operation:
DTC 3242.2-SE13174
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine Speed ≤ 600 RPM
NOT [DOC Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond383.2.)]
Module-off time > 28,800 sec
Module-off time status is valid
Key switch is ON and diagnostic has not made a decision in current key cycle.

Abort Conditions (any active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine speed > 600 RPM for 10 sec.
DOC Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond383.2.)

Pause Conditions (any active):


DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
Module-off time ≤ 28,800 sec
Module-off time status is not valid

Malfunction Thresholds (all active):


Average DOC Outlet temperature over 2 seconds ≥ 70 °C

Cummins Inc. Revision Date: March 30, 2017 124


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

81. 3242.16-SE3069: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Aftertreatment DPF inlet gas temperature is continuously above a high threshold for a calibrated period
of time while active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 3242.16-SE3069
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 100 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


(Engine running condition (See RefCond368.1.) AND NOT[Dosing check conditions for Non-Regen
severe temperature faults. (See RefCond468.1.)])for time ≥ 540 sec

Pause Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)

Malfunction Thresholds (all active):


DOC outlet temperature > 735 °C

Cummins Inc. Revision Date: March 30, 2017 125


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

82. 3242.15-SE1759: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Valid But Above Normal Operating Range -
Least Severe Level
Persistent temperature overshoots of the aftertreatment DPF inlet gas temperature during active
regeneration of the DPF

Monitor Operation:
DTC 3242.15-SE1759
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 unique occurrences of temperature overshoots
persisting for a minimum of 5 seconds each .
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
DPF Regeneration is Active

Abort Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508

Malfunction Thresholds (all active):


DOC Outlet temperature > 650 °C

Cummins Inc. Revision Date: March 30, 2017 126


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

83. 3242.0-SE3591: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature - Data Valid But Above Normal Operating Range -
Most Severe Level
(Aftertreatment DPF inlet gas temperature) OR (Aftertreatment DOC delta gas temperature)
continuously above a severe, high threshold for a calibrated period of time

Monitor Operation:
DTC 3242.0-SE3591
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Case A: 30 seconds OR Case B: 90 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DOC Inlet temperature > 200 °C
DOC Outlet temperature > 200 °C

Pause Conditions (any active):


DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)

Malfunction Thresholds (all active):


Case A: DOC Outlet temperature > 800 °C
OR
Case B: DOC Outlet temperature - DOC inlet temperature > 540 °C

Cummins Inc. Revision Date: March 30, 2017 127


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

84. 3750.31-SE7455: Aftertreatment Diesel Particulate Filter 1


Conditions Not Met for Active Regeneration - Condition Exists
The engine control module is unable to begin closed loop control of active regeneration of DPF due to
low DOC temperature.

Monitor Operation:
DTC 3750.31-SE7455
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 90 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine Speed > 400 RPM for 200 seconds
Ambient Air Pressure ≥ 75 kPa(absolute)
Ambient Air Temperature ≥ -6.7 °C
Active regeneration of DPF in mission desoot mode has been requested for more than 300 sec

Abort Conditions (any active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
Engine Speed ≤ 1,200 RPM for 60 seconds.
Engine Fueling ≤ 35 mg/stroke for 60 seconds.

Pause Conditions (any active):


Engine Speed ≤ 1,200 RPM
Engine Fueling ≤ 35 mg/stroke
The above two Pause Conditions turns from true to false for less than 30 seconds.

Malfunction Thresholds (all active):


DOC Bed Temperature < 280 °C

Cummins Inc. Revision Date: March 30, 2017 128


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

85. 3251.10-SE2851: Aftertreatment 1 Diesel Particulate Filter


Differential Pressure - Abnormal Rate of Change
Aftertreatment DPF differential pressure sensor signal stuck in-range.

Monitor Operation:
DTC 3251.10-SE2851
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3251.3-SE2849, 3251.4-SE2857
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
Range of exhaust volumetric flow since last decision > 0.3 m3/sec
DPF differential pressure sensor signal not saturated at high exhaust flow: (DPF differential pressure
<= 35 kPa) OR (Exhaust flow <= 2 m3/sec)
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3251.3-SE2849, 3251.4-SE2857
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
Range of exhaust volumetric flow since last decision ≤ 0.3 m3/sec
DPF differential pressure sensor signal saturated at high exhaust flow: (DPF differential pressure > 35
kPa) AND (Exhaust flow > 2 m3/sec)
NOT[Engine running condition (See RefCond368.1.)]

Malfunction Thresholds (all active):


Range of DPF differential pressure < 0.15 kPa

Cummins Inc. Revision Date: March 30, 2017 129


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

86. 3936.15-SE2085: Aftertreatment 1 Diesel Particulate Filter System


- Data Valid But Above Normal Operating Range - Least Severe
Level
Aftertreatment DPF differential pressure sensor signal in-range but reading inappropriately high.

Monitor Operation:
DTC 3936.15-SE2085
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
DPF delta pressure sensor error is not detected. (See RefCond485.1.)
The system detects that the DPF is no longer new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond156.4.)

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
DPF delta pressure sensor error is detected. (See RefCond466.1.)
The system considers that the DPF is new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond157.4.)

Pause Conditions (any active):


(Exhaust volumetric flow < 0.18 m3/sec) OR ( 0.18 m3/sec <= Exhaust volumetric flow <= 0.19 m3/sec
AND derivative of Exhaust volumetric flow < 0 m3/sec2)

Malfunction Thresholds (all active):


DPF Differential Pressure > Ash adjusted Delta Pressure High Threshold Where: The Ash adjusted
Delta Pressure High Threshold is the interpolated value between two 2D tables such that the No Ash
table is utilized when no ash is estimated and the Full Ash table is utilized when full ash is estimated.
The No Ash table is defined by RefTable191.3 The Full Ash table is defined by RefTable190.3

Cummins Inc. Revision Date: March 30, 2017 130


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 131


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

87. 3251.2-SE7316: Aftertreatment Diesel Particulate Filter Differential


Pressure - Data Erratic, Intermittent, or Incorrect
Aftertreatment DPF differential pressure sensor key-off check indicates signal in-range but not rational.

Monitor Operation:
DTC 3251.2-SE7316
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3251.3-SE2849, 3251.4-SE2857
Key Switch is OFF AND Engine Speed is 0 rpm for 54 seconds
Before Key Switch turns Off, DPF Outlet Temperature ≥ 200 deg C ANDEngine running condition (See
RefCond368.1.) AND The above two conditions are true for 100 seconds.

Abort Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3251.3-SE2849, 3251.4-SE2857
Key Switch is ON OR Engine Speed is not 0 rpm.

Malfunction Thresholds (all active):


Absolute value of averaged DPF delta pressure measured by the delta P sensor > 1 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 132


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

88. 3251.3-SE2849: Aftertreatment Diesel Particulate Filter Differential


Pressure Sensor Circuit - Voltage Above Normal or Shorted to High
Source
Aftertreatment DPF Delta Pressure sensor reading greater than specified operating range for a
calibrated amount of time.

Monitor Operation:
DTC 3251.3-SE2849
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Aftertreatment DPF Delta Pressure sensor value > 4.75 V (36.733 kPa)

Cummins Inc. Revision Date: March 30, 2017 133


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

89. 3251.4-SE2857: Aftertreatment Diesel Particulate Filter Differential


Pressure Sensor Circuit - Voltage Below Normal or Shorted to Low
Source
Aftertreatment DPF Delta Pressure sensor reading less than specified operating range for a calibrated
amount of time.

Monitor Operation:
DTC 3251.4-SE2857
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Aftertreatment DPF Delta Pressure sensor value < 0.25 V (-3.983 kPa)

Cummins Inc. Revision Date: March 30, 2017 134


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

90. 3246.16-SE3072: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Aftertreatment DPF delta gas temperature is continuously above a high threshold for a calibrated period
of time while active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 3246.16-SE3072
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 140 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
(Engine running condition (See RefCond368.1.) AND NOT[Dosing check conditions for Non-Regen
severe temperature faults. (See RefCond468.1.)])for time ≥ 700 sec

Pause Conditions (any active):


3246.2-SE13175, 3246.2-SE2852, 3246.21-SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)
DPF outlet temperature ≤ 200 °C
DOC outlet temperature ≤ 200 °C

Malfunction Thresholds (all active):


DPF outlet temperature - DOC outlet temperature > 400 °C

Cummins Inc. Revision Date: March 30, 2017 135


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

91. 5319.31-SE3036: Aftertreatment Diesel Particulate Filter


Incomplete Regeneration - Condition Exists
System has detected incomplete regeneration of aftertreatment DPF. This diagnostic feature is
essentially a rationality check between the model-based and sensor-based soot load estimate. The OBD
system shall detect an incomplete regeneration when the model has predicted that regeneration has
completed but more direct indicators (such as pressure signature) indicates the regeneration has not
been completed properly. This could be caused by soot failed to be removed under conditions where it
is expected to be removed. Or it can be caused by high ash loading that is holding DPF back pressure
high even with insignificant amount of soot in the filter

Monitor Operation:
DTC 5319.31-SE3036
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
The system detects that the DPF is no longer new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond156.4.)
Time in active regeneration >= 300 seconds, AND percentage of time during the active regeneration
when the DPF inlet temperature within 100 degC of target temperature >= 40 %
The time period during active regeneration that DPF volumetric flow rate is > 0.18 m3/sec is > 10
seconds.
At the end of the active regeneration, the Diagnostic Model Based Soot Load Estimate <= 3 g/L.

Cummins Inc. Revision Date: March 30, 2017 136


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

DPF delta pressure sensor error is not detected. (See RefCond485.1.)


NOT[Active faults with DPF delta pressure sensor defaulted. (See RefCond467.1.)]

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
The system considers that the DPF is new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond157.4.)
Time in active regeneration < 300 seconds.
Percentage of time during the active regeneration when the DPF inlet temperature within 100degC of
target temperature < 40 %
The time period during active regeneration that DPF volumetric flow rate is > 0.18 m3/sec is <= 10
seconds.
At the end of the active regeneration, the Diagnostic Model Based Soot Load Estimate > 3 g/L.
DPF delta pressure sensor error is detected. (See RefCond466.1.)
Active faults with DPF delta pressure sensor defaulted. (See RefCond467.1.)

Malfunction Thresholds (all active):


DPF differential pressure based soot load estimate > RefTable65.4
Immediately after the end of active DPF regeneration in which no abort conditions occurred

Cummins Inc. Revision Date: March 30, 2017 137


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

92. 4795.31-SE1752: Aftertreatment 1 Diesel Particulate Filter Missing


- Condition Exists
Detection of aftertreatment DPF malfunction.

Monitor Operation:
DTC 4795.31-SE1752
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
DPF delta pressure sensor error is not detected. (See RefCond485.1.)
Exhaust flow ≥ 0.3 m3/sec
0 m3/sec ≤ Exhaust flow ≤ 0.9 m3/sec

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
DPF delta pressure sensor error is detected. (See RefCond466.1.)
Exhaust flow ≥ 0.9 m3/sec

Pause Conditions (any active):


Exhaust flow < 0.3 m3/sec

Malfunction Thresholds (all active):


Exhaust flow resistance (DPF differential pressure / volumetric exhaust flow) < RefTable2.5

Cummins Inc. Revision Date: March 30, 2017 138


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

93. 3610.10-SE2983: Aftertreatment 1 Diesel Particulate Filter Outlet


Pressure - Abnormal Rate of Change
Aftertreatment DPF outlet pressure sensor signal stuck in-range.

Monitor Operation:
DTC 3610.10-SE2983
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3610.3-SE2882, 3610.4-SE2883
Range of exhaust volumetric flow since last decision > 0.35 m3/sec
DPF outlet pressure sensor signal not saturated at high exhaust flow: (DPF outlet pressure <= 20
kPa(gauge)) OR (Exhaust flow <= 2 m3/sec)
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3610.3-SE2882, 3610.4-SE2883
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
DPF outlet pressure sensor signal saturated at high exhaust flow: (DPF outlet pressure > 20
kPa(gauge)) AND (exhaust flow > 2 m3/sec)
NOT[Engine running condition (See RefCond368.1.)]

Malfunction Thresholds (all active):


Range of DPF outlet pressure since last decision in current key cycle until the enable conditions are
met < 0.1 kPa

Cummins Inc. Revision Date: March 30, 2017 139


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

94. 3610.20-SE3284: Aftertreatment 1 Diesel Particulate Filter Outlet


Pressure Sensor - Data Not Rational - Drifted High
Aftertreatment DPF outlet pressure sensor signal in-range but reading inappropriately high.

Monitor Operation:
DTC 3610.20-SE3284
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3610.3-SE2882, 3610.4-SE2883
(Exhaust flow > 0.35 m3/sec) OR (Exhaust flow >= 0.25 m3/sec and derivative of Exhaust flow > 0
m3/sec^2.)
(No Reactive regen trigger is active. (See RefCond475.2.) event is currently being requested) OR
3703.31-SE5571 is active.

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3610.3-SE2882, 3610.4-SE2883
DPF outlet pressure is above the malfunction criteria for 29 seconds which can trigger AECD 10-1 for
active/intrusive injection of hydrocarbons to elevate the temperature of the aftertreatment system
with the objective of mitigating the adverse effects of a suspected DEF deposit.

Pause Conditions (any active):


Exhaust flow < 0.25 m3/sec

Malfunction Thresholds (all active):


DPF outlet pressure > RefTable1.1

Cummins Inc. Revision Date: March 30, 2017 140


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

95. 3610.2-SE7317: Aftertreatment 1 Diesel Particulate Filter Outlet


Pressure - Data Erratic, Intermittent, or Incorrect
Aftertreatment DPF Outlet pressure sensor key-off check indicates signal in-range but not rational.

Monitor Operation:
DTC 3610.2-SE7317
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3610.3-SE2882, 3610.4-SE2883
Key Switch is OFF for 54 seconds.
Engine Speed is 0 rpm for 54 seconds.
Before Key Switch turns Off, ( DPF Outlet Temperature ≥ 200 deg C AND Engine running condition
(See RefCond368.1.) AND The above two conditions are true for 100 seconds. )

Abort Conditions (any active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3610.3-SE2882, 3610.4-SE2883
Key Switch is On OR Key Switch is Off for less than 54 seconds.
Engine Speed is not 0 rpm OR Engine Speed is 0 rpm for less than 54 seconds.
Before Key Switch turns Off, ( DPF Outlet Temperature < 200 deg C OR NOT[Engine running condition
(See RefCond368.1.)] OR The above two conditions are false for less than 100 seconds. )

Malfunction Thresholds (all active):


Absolute value of averaged DPF Outlet pressure > 1 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 141


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

96. 3610.3-SE2882: Aftertreatment 1 Diesel Particulate Filter Outlet


Pressure Sensor Circuit - Voltage Above Normal or Shorted to High
Source
Aftertreatment DPF Outlet pressure sensor reading greater than specified operating range for a
calibrated amount of time.

Monitor Operation:
DTC 3610.3-SE2882
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Aftertreatment DPF Outlet pressure sensor value > 4.75 V (36.733 kPa(gauge))

Cummins Inc. Revision Date: March 30, 2017 142


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

97. 3610.4-SE2883: Aftertreatment 1 Diesel Particulate Filter Outlet


Pressure Sensor Circuit - Voltage Below Normal or Shorted to Low
Source
Aftertreatment DPF Outlet pressure sensor reading less than specified operating range for a calibrated
amount of time.

Monitor Operation:
DTC 3610.4-SE2883
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Aftertreatment DPF outlet pressure sensor value < 0.25 V ( -6.245 kPa(gauge))

Cummins Inc. Revision Date: March 30, 2017 143


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

98. 3246.21-SE13178: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature Sensor - Data Not Rational - Drifted Low
Exhaust gas temperature sensor at DPF Outlet is in-range low.

Monitor Operation:
DTC 3246.21-SE13178
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
Engine is not in motoring condition for 300sec
Engine speed > 600 rpm for 300 sec.
(Ambient air temperature > 0 degC AND Ambient Air Temperature Status is valid.) OR (( ( (Ambient air
temperature < 0 degC and Ambient Air Temperature status is valid) OR Ambient air temperature
status is not valid) AND Engine speed is > 600 rpm for 300 sec AND Exhaust flow rate is >= 100 g/sec
for 300 sec) for 60 sec).
Exhaust flow rate ≥ 100 g/sec for 300 sec.
NOT [DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See
RefCond386.2.)]
NOT[DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond64.2.)]

Abort Conditions (any active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
5742.9-SE12508
DPF Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond385.2.)

Pause Conditions (any active):


Engine is in motoring condition for 30 sec.
Engine speed is ≤ 600 rpm for 30 sec.
Exhaust flow rate is < 100 g/sec for 30 sec.

Malfunction Thresholds (all active):


Average DPF Outlet temperature over 10 seconds < 70 °C

Cummins Inc. Revision Date: March 30, 2017 144


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 145


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

99. 3246.2-SE2852: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Erratic, Intermittent, or Incorrect
Aftertreatment DPF Outlet Gas Temperature is in-range but not rational.

Monitor Operation:
DTC 3246.2-SE2852
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-
SE13176
5742.9-SE12508
Engine running condition (See RefCond368.1.)
Elapsed time since last active regeneration ≥ 300 sec
115 g/sec ≤ Exhaust flow
103 degC ≤ (DOC intake or DOC outlet or DPF outlet) gas temperature ≤ 500 degC
300 seconds have elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728

Cummins Inc. Revision Date: March 30, 2017 146


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4765.2-SE13173, 4765.2-


SE13176
5742.9-SE12508
Regeneration is Active
Elapsed time since last active regeneration < 300 sec

Pause Conditions (any active):


OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond66.2.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond64.2.)
DOC Inlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond382.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


-70 degC < average of (DOC inlet - DOC outlet) < 65 degC
(Average of (DOC outlet - DPF outlet) > 85 degC) OR (Average of (DOC outlet - DPF outlet) < -70 degC)

Cummins Inc. Revision Date: March 30, 2017 147


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

100. 3246.2-SE13175: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at DPF Outlet is in-range high.

Monitor Operation:
DTC 3246.2-SE13175
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine Speed ≤ 600 RPM
NOT [DPF Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond385.2.)]
Module-off time > 28,800 sec
Module-off time status is valid
Key switch is ON and diagnostic has not made a decision in current key cycle.

Abort Conditions (any active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
Engine speed > 600 RPM for 10 Sec.
DPF Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond385.2.)

Pause Conditions (any active):


DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)
DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond64.2.)
Keyswitch is OFF
Module-off time ≤ 28,800 sec
Module-off time status is not valid

Malfunction Thresholds (all active):


Average DPF Outlet temperature over 2 seconds ≥ 70 °C

Cummins Inc. Revision Date: March 30, 2017 148


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

101. 3246.16-SE3071: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Aftertreatment DPF outlet gas temperature is continuously above a high threshold for a calibrated
period of time while active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 3246.16-SE3071
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 145 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


(Engine running condition (See RefCond368.1.) AND NOT[Dosing check conditions for Non-Regen
severe temperature faults. (See RefCond468.1.)])for time ≥ 700 sec

Pause Conditions (any active):


3246.2-SE13175, 3246.2-SE2852, 3246.21-SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734,
5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-
SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


DPF Outlet Temperature > 735 °C

Cummins Inc. Revision Date: March 30, 2017 149


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

102. 3246.15-SE1754: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Valid But Above Normal Operating Range -
Least Severe Level
Persistent temperature overshoots of the Aftertreatment DPF outlet gas temperature during active
regeneration of the DPF.

Monitor Operation:
DTC 3246.15-SE1754
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 unique occurrences of temperature overshoots
persisting for a minimum of 10 seconds each.
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
DPF Regeneration is Active

Abort Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508

Malfunction Thresholds (all active):


DPF outlet temperature > 650 °C

Cummins Inc. Revision Date: March 30, 2017 150


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

103. 3936.2-SE13050: Aftertreatment 1 Diesel Particulate Filter System


- Data Erratic, Intermittent, or Incorrect
The system has detected the filtration efficiency of the DPF is below the minimum required threshold by
comparing PM sensor electrode current to expected soot quantity.

Monitor Operation:
DTC 3936.2-SE13050
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4795.31-SE1752
5835.3-SE12918
5835.4-SE12919
7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
7321.4-SE12915
6778.16-SE12924
6778.3-SE12920
6773.7-SE13070
6777.10-SE12950
7854.2-SE13054
7329.2-SE12922
7329.2-SE12923
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5835.21-SE13109
5569.16-SE13115
6773.16-SE13097
6780.2-SE13095

Cummins Inc. Revision Date: March 30, 2017 151


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

6780.2-SE13096
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
Diagnostic has not made an increment or decrement count in the last 10 sec.
PM filtration efficiency diagnostic has not made a pass or fail decision in the current drive cycle.
Exhaust flow velocity ≥ 5 m/sec FOR ≥ 0 sec AND exhaust flow velocity sensor status is data valid.
Aftertreatment is in Base Mode for the last 720 sec.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the PM sensor element. (See RefCond160.23.)
NOT [Abort condition to disable the diagnostics when ambient temperature or pressure are outside
limit threshold values. (See RefCond132.7.)]
Fuel system failure is not present (See RefCond455.2.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
NOT[PM sensor is in measurement mode for too long, with out making a diagnostic increment or
decrement decision. (See RefCond200.1.)]
NOT[PM sensor has reactivated and exited measurement mode greater than or equal to a
calibratable number of occurance counts prior to making a decision in the current drive cycle. (See
RefCond203.1.)]
PM sensor probe temperature and exhaust temperature at sensor closest to the PM sensor should be
within a range for the sensor measurement to be enabled. (See RefCond204.3.)
Exhaust flow and temperature conditions are favorable for a succesful PM sensor regeneration. (See
RefCond201.5.)

Abort Conditions (any active):


4795.31-SE1752
5835.3-SE12918
5835.4-SE12919
7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
7321.4-SE12915
6778.16-SE12924
6778.3-SE12920
6773.7-SE13070
6777.10-SE12950
7854.2-SE13054
7329.2-SE12922
7329.2-SE12923
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963

Cummins Inc. Revision Date: March 30, 2017 152


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5835.21-SE13109
5569.16-SE13115
6773.16-SE13097
6780.2-SE13095
6780.2-SE13096
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
Diagnostic has made an increment or decrement decision in the last 10 sec
PM filtration efficiency diagnostic has made a pass or fail decision this drive cycle.
Exhaust flow velocity is ≤ 5 m/sec FOR ≥ 0 sec OR exhaust flow velocity sensor status is not data valid.
The aftertreatment is not in Base Mode.
The aftertreatment mode has changed to Base Mode in the last 720 sec.
Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond130.22.)
Abort condition to disable the diagnostics when ambient temperature or pressure are outside limit
threshold values. (See RefCond132.7.)
NOT [ Fuel system failure is not present (See RefCond455.2.) ]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor has reactivated and exited measurement mode greater than or equal to a calibratable
number of occurance counts prior to making a decision in the current drive cycle. (See RefCond203.1.)
PM sensor is in measurement mode for too long, with out making a diagnostic increment or
decrement decision. (See RefCond200.1.)
NOT[Exhaust flow and temperature conditions are favorable for a succesful PM sensor regeneration.
(See RefCond201.5.)]

Malfunction Thresholds (all active):


Particulate Matter (PM) sensor electrode current ≥ 12 microA AND the expected quantity of PM
accumulation < 0.7 g for 2 counts.

Cummins Inc. Revision Date: March 30, 2017 153


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

104. 3246.0-SE3592: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature - Data Valid But Above Normal Operating Range -
Most Severe Level
Aftertreatment DPF outlet gas temperature continuously above a severe, high threshold for a calibrated
period of time.

Monitor Operation:
DTC 3246.0-SE3592
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 35 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508

Malfunction Thresholds (all active):


DPF outlet temperature > 810 °C

Cummins Inc. Revision Date: March 30, 2017 154


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

105. 3251.16-SE1887: Aftertreatment Diesel Particulate Filter


Differential Pressure - Data Valid But Above Normal Operating
Range - Moderately Severe Level
Aftertreatment DPF Soot Load Estimate has increased above the Moderate Severe Level

Monitor Operation:
DTC 3251.16-SE1887
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Soot Load Estimate > 8 g/L

Cummins Inc. Revision Date: March 30, 2017 155


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

106. 3251.15-SE2096: Aftertreatment Diesel Particulate Filter


Differential Pressure - Data Valid But Above Normal Operating
Range - Least Severe Level
Aftertreatment DPF Soot Load Estimate has increased above the Least Severe Level

Monitor Operation:
DTC 3251.15-SE2096
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Soot Load Estimate > 7.5 g/L

Cummins Inc. Revision Date: March 30, 2017 156


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

107. 3251.0-SE2097: Aftertreatment Diesel Particulate Filter Differential


Pressure - Data Valid But Above Normal Operating Range - Most
Severe Level
Aftertreatment DPF Soot Load Estimate has increased above the Most Severe Level

Monitor Operation:
DTC 3251.0-SE2097
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Soot Load Estimate > 9 g/L

Cummins Inc. Revision Date: March 30, 2017 157


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

108. 5397.31-SE3590: Aftertreatment Diesel Particulate Filter


Regeneration too Frequent - Condition Exists
Aftertreatment DPF system active regeneration occurring more frequently than intended.

Monitor Operation:
DTC 5397.31-SE3590
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


5298.18-SE4719
4796.31-SE1757
3242.15-SE1759
3242.0-SE3591
4765.16-SE3068
3242.16-SE3069
3242.16-SE3070
5298.17-SE3545
3246.0-SE3592
3246.15-SE1754
3246.16-SE3071
3936.15-SE2085
3246.16-SE3072
3251.0-SE2097
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366

Cummins Inc. Revision Date: March 30, 2017 158


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-


SE389
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-
SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-
SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
3597.2-SE294
Engine speed > 50 RPM
Active regeneration of DPF not disabled due to Active errors within the SCR system that will disable
active/intrusive injection of HCs into the exhaust in order to protect the SCR system (See
RefCond114.4.)
The system detects that the DPF is no longer new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond156.4.)
DPF delta pressure sensor error is not detected. (See RefCond485.1.)
NOT[Active faults with DPF delta pressure sensor defaulted. (See RefCond467.1.)]

Abort Conditions (any active):


5298.18-SE4719
4796.31-SE1757
3242.15-SE1759
3242.0-SE3591
4765.16-SE3068
3242.16-SE3069
3242.16-SE3070
5298.17-SE3545
3246.0-SE3592
3246.15-SE1754
3246.16-SE3071

Cummins Inc. Revision Date: March 30, 2017 159


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3936.15-SE2085
3246.16-SE3072
3251.0-SE2097
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-
SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-
SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
3597.2-SE294
Active errors within the SCR system that will disable active/intrusive injection of HCs into the exhaust
in order to protect the SCR system (See RefCond114.4.)

Cummins Inc. Revision Date: March 30, 2017 160


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

The system considers that the DPF is new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.
(See RefCond157.4.)
DPF delta pressure sensor error is detected. (See RefCond466.1.)
Active faults with DPF delta pressure sensor defaulted. (See RefCond467.1.)

Pause Conditions (any active):


Engine speed < 50 RPM

Malfunction Thresholds (all active):


Elapsed time since the last active regeneration of the DPF completed and the next active regeneration
is requested < RefTable46.3 hr
Number of failed decisions out of 3 updates made >=2

Cummins Inc. Revision Date: March 30, 2017 161


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

109. 91.2-SE1380: Accelerator Pedal or Lever Position Sensor 1 - Data


Erratic, Intermittent, or Incorrect
Dual Potentiometer Accelerator Rationality Check

Monitor Operation:
DTC 91.2-SE1380
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


2623.3-SE1378
2623.4-SE1379
91.3-SE63
91.4-SE64
3512.3-SE817
3512.4-SE815
3513.3-SE1893
3513.4-SE1894
Dual Potentiometer Accelerator = Enabled

Pause Conditions (any active):


2623.3-SE1378
2623.4-SE1379
91.3-SE63
91.4-SE64
3512.3-SE817
3512.4-SE815
3513.3-SE1893
3513.4-SE1894

Malfunction Thresholds (all active):


(Primary Accelerator Pedal Position > (Secondary Accelerator Pedal Position + 10%)) OR (Primary
Accelerator Pedal Position < (Secondary Accelerator Pedal Position - 10%))

Cummins Inc. Revision Date: March 30, 2017 162


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

110. 91.8-SE6991: Accelerator Pedal or Lever Position Sensor 1 Circuit


Frequency - Abnormal Frequency or Pulse Width or Period
Primary PWM Accelerator Pedal Base Frequency Out-of-Range

Monitor Operation:
DTC 91.8-SE6991
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3512.3-SE817
3512.4-SE815

Abort Conditions (any active):


3512.3-SE817
3512.4-SE815

Malfunction Thresholds (all active):


Base Frequency of Primary PWM accelerator pedal < 180Hz OR Base Frequency of Primary PWM
accelerator pedal > 220Hz

Cummins Inc. Revision Date: March 30, 2017 163


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

111. 91.8-SE6990: Accelerator Pedal or Lever Position Sensor 1 Circuit


Frequency - Abnormal Frequency or Pulse Width or Period
Primary PWM Accelerator Pedal Duty Cycle Out-of-Range

Monitor Operation:
DTC 91.8-SE6990
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3512.3-SE817
3512.4-SE815

Abort Conditions (any active):


3512.3-SE817
3512.4-SE815

Malfunction Thresholds (all active):


PWM Primary Pedal Position < 15% OR PWM Primary Pedal Position > 95%

Cummins Inc. Revision Date: March 30, 2017 164


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

112. 2623.8-SE6993: Accelerator Pedal or Lever Position Sensor 2


Circuit Frequency - Abnormal Frequency or Pulse Width or Period
Secondary PWM Accelerator Pedal Base Frequency Out-of-Range

Monitor Operation:
DTC 2623.8-SE6993
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3513.3-SE1893
3513.4-SE1894

Abort Conditions (any active):


3513.3-SE1893
3513.4-SE1894

Malfunction Thresholds (all active):


Base Frequency of Secondary PWM accelerator pedal < 180Hz OR Base Frequency of Secondary PWM
accelerator pedal > 220Hz

Cummins Inc. Revision Date: March 30, 2017 165


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

113. 2623.8-SE6992: Accelerator Pedal or Lever Position Sensor 2


Circuit Frequency - Abnormal Frequency or Pulse Width or Period
Secondary PWM Accelerator Pedal Duty Cycle Out-of-Range

Monitor Operation:
DTC 2623.8-SE6992
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3513.3-SE1893
3513.4-SE1894

Abort Conditions (any active):


3513.3-SE1893
3513.4-SE1894

Malfunction Thresholds (all active):


Dual PWM Secondary Pedal Position < 5% OR Dual PWM Secondary Pedal Position > 50%

Cummins Inc. Revision Date: March 30, 2017 166


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

114. 629.12-SE216: Engine Control Module Critical Internal Failure - Bad


Intelligent Device or Component
Engine control module non-volatile (Flash) memory failure.

Monitor Operation:
DTC 629.12-SE216
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.04 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Fail to save the data to the non-volatile memory.

Cummins Inc. Revision Date: March 30, 2017 167


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

115. 411.3-SE485: Exhaust Gas Recirculation Differential Pressure


Sensor Circuit - Voltage Above Normal or Shorted to High Source
EGR Delta Pressure sensor reading greater than specified operating range for a calibrated amount of
time.

Monitor Operation:
DTC 411.3-SE485
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


EGR Delta Pressure sensor value > 4.75V (36.932 kPa)

Cummins Inc. Revision Date: March 30, 2017 168


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

116. 411.4-SE483: Exhaust Gas Recirculation Differential Pressure


Sensor Circuit - Voltage Below Normal or Shorted to Low Source
EGR Delta Pressure sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 411.4-SE483
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


EGR Delta Pressure sensor value < 0.25V (-7.462 kPa)

Cummins Inc. Revision Date: March 30, 2017 169


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

117. 411.2-SE1911: Exhaust Gas Recirculation Differential Pressure -


Data Erratic, Intermittent, or Incorrect
EGR Delta Pressure Sensor Autozero Error

Monitor Operation:
DTC 411.2-SE1911
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1 counts
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Engine Speed = 0 RPM
EGR Valve is closed
Charge Temperature > 16 °C
Coolant Temperature > 68 °C
Key Switch is OFF after being on
All enable conditions have been TRUE for 2 sec

Abort Conditions (any active):


27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-SE488
411.3-SE485, 411.4-SE483

Malfunction Thresholds (all active):


The absolute value of EGR Delta Pressure Sensor > Threshold value taken from table RefTable113.2

Cummins Inc. Revision Date: March 30, 2017 170


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

118. 2791.3-SE2797: EGR Valve Control Circuit - Voltage Above Normal


or Shorted to High Source
The ECM monitors whether the H-Bridge circuit that drives an EGR actuator motor is shorted to a high
voltage source.

Monitor Operation:
DTC 2791.3-SE2797
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through low-side switches of EGR H-Bridge circuit > 12.6 A

Cummins Inc. Revision Date: March 30, 2017 171


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

119. 2791.4-SE2798: EGR Valve Control Circuit - Voltage Below Normal


or Shorted to Low Source
The ECM monitors whether the H-Bridge circuit that drives an EGR actuator motor is shorted to a low
voltage source.

Monitor Operation:
DTC 2791.4-SE2798
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through high-side switches of EGR H-Bridge circuit > 12.6 A

Cummins Inc. Revision Date: March 30, 2017 172


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

120. 2791.3-SE3582: EGR Valve Control Circuit - Voltage Above Normal


or Shorted to High Source
The ECM monitors whether the H-Bridge circuit that drives an EGR actuator motor has an open-load
condition.

Monitor Operation:
DTC 2791.3-SE3582
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through low-side switches of EGR H-Bridge circuit < 1 mA while being driven by a zero PWM
signal at ECM power up

Cummins Inc. Revision Date: March 30, 2017 173


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

121. 27.2-SE3866: EGR Valve Position - Data Erratic, Intermittent, or


Incorrect
The EGR valve position feedback value is In Range, High.

Monitor Operation:
DTC 27.2-SE3866
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration ≤ 15 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


2791.3-SE2797
2791.4-SE2798
2791.3-SE3582
EGR actuator is in PWM-Off state.
EGR span check is in progress (See TECDES for 2791.13-SE3980 for further details).
EGR auto zero is in progress (See TECDES for 2791.13-SE3980 for further details).

Malfunction Thresholds (all active):


Average of (Measured Value - Commanded Value) over a 15 second period is ever > 20 %. Where
Diagnostic Tolerance is defined as 0 %.

Cummins Inc. Revision Date: March 30, 2017 174


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

122. 27.2-SE3867: EGR Valve Position - Data Erratic, Intermittent, or


Incorrect
The EGR valve position feedback value is In Range, Low.

Monitor Operation:
DTC 27.2-SE3867
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration ≤ 15 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


2791.3-SE2797
2791.4-SE2798
2791.3-SE3582
EGR actuator is in PWM-Off state.
EGR span check is in progress (See TECDES for 2791.13-SE3980 for further details).
EGR auto zero is in progress (See TECDES for 2791.13-SE3980 for further details).

Malfunction Thresholds (all active):


Average of (Commanded Value - Measured Value) over a 15 second period is ever > 20 %. Where
Diagnostic Tolerance is defined as 0 %.

Cummins Inc. Revision Date: March 30, 2017 175


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

123. 27.3-SE3202: EGR Valve Position Circuit - Voltage Above Normal or


Shorted to High Source
EGR valve position sensor reading is greater than specified operating range for a calibrated amount of
time.

Monitor Operation:
DTC 27.3-SE3202
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Measured EGR H-Bridge valve position > 77.864 V (109.044 %)

Cummins Inc. Revision Date: March 30, 2017 176


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

124. 27.4-SE3203: EGR Valve Position Circuit - Voltage Below Normal or


Shorted to Low Source
EGR valve position sensor reading is less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 27.4-SE3203
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Measured EGR H-Bridge valve position < 2.038 V (-9.317 %)

Cummins Inc. Revision Date: March 30, 2017 177


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

125. 2791.13-SE3980: EGR Valve Controller - Out of Calibration


The EGR valve autozero error is set if, the zero position or the span of the actuator is not within allowed
limits, or autozero process could not finish in the allowed time.

Monitor Operation:
DTC 2791.13-SE3980
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 22 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


2791.3-SE2797, 2791.3-SE3582, 2791.4-SE2798
Battery Voltage > 10 V
Engine Speed < 650 RPM
Coolant Temperature > 85 °C
Position status is data valid.
Enable conditions must be met in ≤ 2 seconds.
This monitor only runs once at either key on or key off.

Malfunction Thresholds (all active):


The absolute value of (minimum measured position - 0%) ≥ 10%.
OR
The calculated span < 80%.
OR
The calculated span > 120%.
OR
The autozero or span check process could not finish in 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 178


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

126. 412.2-SE3876: Exhaust Gas Recirculation Temperature - Data


Erratic, Intermittent, or Incorrect
EGR Orifice Temperature reading is In Range High

Monitor Operation:
DTC 412.2-SE3876
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 60 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine has been in Run state for >= 120 s

Pause Conditions (any active):


412.3-SE496, 412.4-SE495
412.2-SE3872
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-
SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3877, 412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-
SE76, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-SE1911,
411.3-SE485, 411.4-SE483
27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
Coolant Temperature < 60 °C
EGR Orifice Temperature < 250 DegC AND EGR Flow < 1.5 kg/min

Malfunction Thresholds (all active):


Average of (EGR Orifice Temperature - Estimated EGR Orifice Temperature) over a 60 second period is
ever ≥ 208.5 degC Diagnostic Tolerance = 207.5 degC
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 179


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

127. 412.2-SE3877: Exhaust Gas Recirculation Temperature - Data


Erratic, Intermittent, or Incorrect
EGR Orifice Temperature reading is In Range Low

Monitor Operation:
DTC 412.2-SE3877
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 60 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine has been in Run state for >= 120 s

Pause Conditions (any active):


412.2-SE3872
412.3-SE496, 412.4-SE495
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-
SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-
SE76, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-SE1911,
411.3-SE485, 411.4-SE483
27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
EGR Flow < 1.5 kg/min
Coolant Temperature < 60 °C
EGR Orifice Temperature < 250 DegC AND EGR Flow < 1.5 kg/min

Malfunction Thresholds (all active):


Average of (Estimated EGR Orifice Temperature - EGR Orifice Temperature) over a 60 seconds is ever
≥ 208.5 degC. Diagnostic Tolerance = 207.5 degC
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 180


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

128. 412.2-SE3878: Exhaust Gas Recirculation Temperature - Data


Erratic, Intermittent, or Incorrect
EGR Orifice Temperature reading is In Range Stuck

Monitor Operation:
DTC 412.2-SE3878
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate.
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine has been in Run state for >= 120 s

Pause Conditions (any active):


412.2-SE3872
412.3-SE496, 412.4-SE495
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-
SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-
SE76, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-SE1911,
411.3-SE485, 411.4-SE483
27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
The difference (absolute value) between engine speed and filtered engine speed is under a Low
Hysteresis threshold 80 RPM, or remains under High Hysteresis threshold 100 RPM.
EGR Flow < 1.5 kg/min
Coolant Temperature < 60 °C
EGR Orifice Temperature < 250 DegC AND EGR Flow < 1.5 kg/min

Malfunction Thresholds (all active):


(Maximum sensor value - Minimum sensor value) at the end of 60 seconds is < 0.3 °C

Cummins Inc. Revision Date: March 30, 2017 181


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

129. 412.2-SE3872: Exhaust Gas Recirculation Temperature - Data


Erratic, Intermittent, or Incorrect
EGR Orifice Temperature sensor reading is erratic, intermittent or incorrect.

Monitor Operation:
DTC 412.2-SE3872
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine off time ≥ 480 min
The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Abort Conditions (any active):


412.3-SE496, 412.4-SE495
251.10-SE4759
251.10-SE4760

Malfunction Thresholds (all active):


| EGR Orifice Temperature sensor - the most accurate sensor from the remaining temperature
sensors | > (25 degC + the tolerance of the most accurate sensor from the remaining temperature
sensors)
| EGR Orifice Temperature sensor - the second most accurate sensor from the remaining temperature
sensors | > (25 degC + the tolerance of the second most accurate sensor from the remaining
temperature sensors)
| the most accurate sensor from the remaining temperature sensors - the second most accurate
sensor from the remaining temperature sensors | < (the tolerance of the most accurate sensor from
the remaining temperature sensors + the tolerance of the second most accurate sensor from the
remaining temperature sensors)
The tolerance of the remaining temperature sensors are:
Compressor Inlet Temperature sensor tolerance = 40 °C
Charge Temperature sensor tolerance = 21 °C
Coolant Temperature sensor tolerance = 20 °C
ECM Internal Temperature sensor tolerance = 210 °C
Air Temperature sensor tolerance = 35 °C

Cummins Inc. Revision Date: March 30, 2017 182


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

130. 412.3-SE496: Exhaust Gas Recirculation Temperature Sensor


Circuit - Voltage Above Normal or Shorted to High Source
EGR Orifice Temperature Sensor reading is greater than specified operating range for calibrated amount
of time.

Monitor Operation:
DTC 412.3-SE496
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


EGR Orifice Temperature sensor value > 4.85V (< -40 degC)

Cummins Inc. Revision Date: March 30, 2017 183


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

131. 412.4-SE495: Exhaust Gas Recirculation Temperature Sensor


Circuit - Voltage Below Normal or Shorted to Low Source
EGR Orifice Temperature Sensor reading is less than specified operating range for calibrated amount of
time.

Monitor Operation:
DTC 412.4-SE495
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


EGR Orifice Temperature sensor value < 0.055V (> 500degC)

Cummins Inc. Revision Date: March 30, 2017 184


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

132. 412.16-SE869: Exhaust Gas Recirculation Temperature - Data Valid


But Above Normal Operating Range - Moderately Severe Level
EGR Orifice Temperature above allowed engine operating range.

Monitor Operation:
DTC 412.16-SE869
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
Engine Speed < 650 RPM

Malfunction Thresholds (all active):


EGR Orifice Temperature > 246 °C

Cummins Inc. Revision Date: March 30, 2017 185


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

133. 412.15-SE870: Exhaust Gas Recirculation Temperature - Data Valid


But Above Normal Operating Range - Least Severe Level
EGR Orifice Temperature above normal engine operating range

Monitor Operation:
DTC 412.15-SE870
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
Engine Speed < 650 RPM

Malfunction Thresholds (all active):


EGR Orifice Temperature > 210 °C

Cummins Inc. Revision Date: March 30, 2017 186


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

134. 3058.16-SE7295: Engine Exhaust Gas Recirculation (EGR) System -


Data Valid But Above Normal Operating Range - Moderately
Severe Level
EGR Flow higher than normal.

Monitor Operation:
DTC 3058.16-SE7295
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 20 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Charge Flow Command < 13 kg/min
Charge Flow Command > 25 kg/min
VGT Actuator Effective Flow Area < 4.5 cm2
VGT Actuator Effective Flow Area > 6 cm2
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
EGR Delta Pressure sensor autozero check is not complete
Engine Speed > 3,000 RPM
Total Fueling < 60 mg/stroke
Total Fueling > 100 mg/stroke
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (EGR Flow - Estimated EGR Flow) over a 20 second period is ever > (0.925 kg/min +
Diagnostic Tolerance) Diagnostic Tolerance = RefTable43.1 (Please refer to the CUSUM Supplement in
Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 187


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

135. 3058.18-SE7296: Engine Exhaust Gas Recirculation (EGR) System -


Data Valid But Below Normal Operating Range - Moderately Severe
Level
EGR Flow lower than normal.

Monitor Operation:
DTC 3058.18-SE7296
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


EGR Flow Command < 1.5 kg/min
EGR Flow Command > 6 kg/min
EGR Valve Effective Flow Area < 2 cm2
EGR Valve Effective Flow Area > 3.1 cm2
EGR Delta Pressure sensor autozero check is not complete
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (Estimated EGR Flow - EGR Flow) over a 30 second period is ever > 3.333 kg/min
Diagnostic Tolerance = 0 kg/min (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 188


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

136. 3058.10-SE12125: Engine Exhaust Gas Recirculation (EGR) System -


Abnormal Rate of Change
EGR System Response slower than normal.

Monitor Operation:
DTC 3058.10-SE12125
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 20 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Charge Flow Command < 10 kg/min
Charge Flow Command > 25 kg/min
VGT Actuator Effective Flow Area < 2 cm2
VGT Actuator Effective Flow Area > 5.5 cm2
EGR Delta Pressure sensor autozero check is not complete
|Rate of change of (Engine Speed * Commanded Fueling)| over 0.1 sec. < 1,000 (rpm * mg) / (stroke
* sec)
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (Estimated EGR Flow - EGR Flow) over a 20 second period is ever > 1 kg/min Diagnostic
Tolerance = 0 kg/min (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 189


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

137. 4765.3-SE6729: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to battery or open circuit
condition that causes too high input voltage condition in the intake DOC thermocouple sensor circuit.

Monitor Operation:
DTC 4765.3-SE6729
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment intake DOC gas temperature sensor input voltage ≥ 3.35 V (1,759 DegC)
OR intake DOC gas temperature thermocouple impedance ≥ 5,400 Ohms

Cummins Inc. Revision Date: March 30, 2017 190


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

138. 4765.4-SE6730: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature Sensor Circuit - Voltage Below Normal or Shorted to
Low Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to ground that causes too
low input voltage condition in the intake DOC thermocouple sensor circuit.

Monitor Operation:
DTC 4765.4-SE6730
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment intake DOC gas temperature sensor input voltage ≤ 1 V (-273 DegC)

Cummins Inc. Revision Date: March 30, 2017 191


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

139. 3242.3-SE6731: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to battery or open circuit
condition that causes too high input voltage condition in the outlet DOC thermocouple sensor circuit.

Monitor Operation:
DTC 3242.3-SE6731
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet DOC gas temperature sensor input voltage ≥ 3.35 V (1,759 DegC)
OR outlet DOC gas temperature thermocouple impedance ≥ 5,400 Ohms

Cummins Inc. Revision Date: March 30, 2017 192


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

140. 3242.4-SE6732: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature Sensor Circuit - Voltage Below Normal or Shorted to
Low Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to ground that causes too
low input voltage condition in the outlet DOC thermocouple sensor circuit.

Monitor Operation:
DTC 3242.4-SE6732
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet DOC gas temperature sensor input voltage ≤ 1 V (-273 DegC)

Cummins Inc. Revision Date: March 30, 2017 193


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

141. 3246.3-SE6733: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to battery or open circuit
condition that causes too high input voltage condition in the outlet DPF thermocouple sensor circuit.

Monitor Operation:
DTC 3246.3-SE6733
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet DPF gas temperature sensor input voltage ≥ 3.35 V (1,759 DegC)
OR outlet DPF gas temperature thermocouple impedance ≥ 5,400 Ohms

Cummins Inc. Revision Date: March 30, 2017 194


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

142. 3246.4-SE6734: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature Sensor Circuit - Voltage Below Normal or Shorted to
Low Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to ground that causes too
low input voltage condition in the outlet DPF thermocouple sensor circuit.

Monitor Operation:
DTC 3246.4-SE6734
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet DPF gas temperature sensor input voltage ≤ 1 V (-273 DegC)

Cummins Inc. Revision Date: March 30, 2017 195


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

143. 5742.12-SE6722: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detetected an open circuit condition in the reference
cold junction thermistor internal to the module.

Monitor Operation:
DTC 5742.12-SE6722
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is turned off

Malfunction Thresholds (all active):


EGTS Module Cold Junction Temperature < -50 °C

Cummins Inc. Revision Date: March 30, 2017 196


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

144. 5742.12-SE6724: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detetected an implausible temperature error condition
in the reference cold junction thermistor internal to the module.

Monitor Operation:
DTC 5742.12-SE6724
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


(EGTS Module Cold Junction Temperature - EGTS ECU Temperature) > 20 °C

Cummins Inc. Revision Date: March 30, 2017 197


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

145. 5742.12-SE6721: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detetected a short circuit condition in the reference
cold junction thermistor internal to the module.

Monitor Operation:
DTC 5742.12-SE6721
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


EGTS Module Cold Junction Temperature > 160 °C

Cummins Inc. Revision Date: March 30, 2017 198


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

146. 5742.12-SE6726: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detetected an ASIC memory corruption error condition
in the internal module circuitry.

Monitor Operation:
DTC 5742.12-SE6726
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


Mismatched or invalid CRC of the Smart Exhaust Gas Temperature Module ASIC internal memory at
power up.

Cummins Inc. Revision Date: March 30, 2017 199


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

147. 5742.3-SE6727: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detetected a too high of a voltage condition to the
control module.

Monitor Operation:
DTC 5742.3-SE6727
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


EGT module supply voltage > 33.6 V

Cummins Inc. Revision Date: March 30, 2017 200


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

148. 5742.4-SE6728: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Voltage Below Normal or Shorted to
Low Source
The Smart Exhaust Gas Temperature Module has detetected a too low of a voltage condition to the
control module.

Monitor Operation:
DTC 5742.4-SE6728
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off
Engine is in cranking state.
Elapsed time since engine has exited the cranking state >= 2 seconds.

Malfunction Thresholds (all active):


EGT module supply voltage < 7.3 V

Cummins Inc. Revision Date: March 30, 2017 201


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

149. 5742.16-SE7167: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Data Valid But Above Normal
Operating Range - Moderately Severe Level
The Smart Exhaust Gas Temperature Module has detetected an ECU temperature too high condition in
the internal module circuitry.

Monitor Operation:
DTC 5742.16-SE7167
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


Smart Exhaust Gas Temperature Module internal circuit board temperature > 150 °C

Cummins Inc. Revision Date: March 30, 2017 202


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

150. 5742.12-SE6725: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detetected mismatched data in the two copies of
microcontroller EEPROM in the module circuitry.

Monitor Operation:
DTC 5742.12-SE6725
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


The Smart Exhaust Gas Temperature Module's parameter storage within nonvolatile memory does
not match the corresponding parameters volatile storage at power up

Cummins Inc. Revision Date: March 30, 2017 203


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

151. 5742.11-SE7168: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Root Cause Not Known
The Smart Exhaust Gas Temperature Module has detetected an intermittent power supply voltage drop
that results in a reset internal to the module.

Monitor Operation:
DTC 5742.11-SE7168
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Time delay after key on ≥ 5 sec
Key switch is on

Abort Conditions (any active):


Key switch is off

Malfunction Thresholds (all active):


The number of EGT module power reset events within a 60 second window is ≥ 12 counts

Cummins Inc. Revision Date: March 30, 2017 204


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

152. 4765.3-SE6735: Aftertreatment 1 Diesel Oxidation Catalyst Intake


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detected an ASIC communication error with the intake
DOC thermocouple.

Monitor Operation:
DTC 4765.3-SE6735
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Within the Smart Exhaust Gas Temperature Module an ASIC communication error is causing no data
transfer between intake DOC thermocouple and the internal ASIC.

Cummins Inc. Revision Date: March 30, 2017 205


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

153. 3242.3-SE6736: Aftertreatment 1 Diesel Particulate Filter Intake


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detected an ASIC communication error with the outlet
DOC thermocouple.

Monitor Operation:
DTC 3242.3-SE6736
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Within the Smart Exhaust Gas Temperature Module an ASIC communication error is causing no data
transfer between outlet DOC thermocouple and the internal ASIC.

Cummins Inc. Revision Date: March 30, 2017 206


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

154. 3246.3-SE6737: Aftertreatment 1 Diesel Particulate Filter Outlet


Temperature Sensor Circuit - Voltage Above Normal or Shorted to
High Source
The Smart Exhaust Gas Temperature Module has detected an ASIC communication error with the outlet
DPF thermocouple.

Monitor Operation:
DTC 3246.3-SE6737
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12508
Key switch is off

Malfunction Thresholds (all active):


Within the Smart Exhaust Gas Temperature Module an ASIC communication error is causing no data
transfer between outlet DPF thermocouple and the internal ASIC.

Cummins Inc. Revision Date: March 30, 2017 207


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

155. 4363.3-SE6762: Aftertreatment 1 SCR Outlet Temperature Sensor


Circuit - Voltage Above Normal or Shorted to High Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to battery or open circuit
condition that causes too high of an input voltage condition in the outlet SCR thermocouple sensor
circuit.

Monitor Operation:
DTC 4363.3-SE6762
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12509
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet SCR gas temperature sensor input voltage ≥ 3.35 V (1,759 DegC)
OR outlet SCR gas temperature thermocouple impedance ≥ 5,400 Ohms

Cummins Inc. Revision Date: March 30, 2017 208


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

156. 4363.4-SE6763: Aftertreatment 1 SCR Outlet Temperature Sensor


Circuit - Voltage Below Normal or Shorted to Low Source
The Smart Exhaust Gas Temperature Module has detetected a sensor short to ground condition that
causes too low of an input voltage condition in the outlet SCR thermocouple sensor circuit.

Monitor Operation:
DTC 4363.4-SE6763
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12509
Key switch is off

Malfunction Thresholds (all active):


Aftertreatment outlet SCR gas temperature sensor input voltage ≤ 1 V (-273 DegC)

Cummins Inc. Revision Date: March 30, 2017 209


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

157. 5743.12-SE6765: Aftertreatment Selective Catalytic Reduction


Temperature Sensor Module - Bad Intelligent Device or
Component
The Smart Exhaust Gas Temperature Module has detected an ASIC communication error with the outlet
SCR thermocouple.

Monitor Operation:
DTC 5743.12-SE6765
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


5742.9-SE12509
Key switch is off

Malfunction Thresholds (all active):


Within the Smart Exhaust Gas Temperature Module an ASIC communication error is causing no data
transfer between outlet SCR thermocouple and the internal ASIC.

Cummins Inc. Revision Date: March 30, 2017 210


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

158. 111.18-SE657: Coolant Level - Data Valid But Below Normal


Operating Range - Moderately Severe Level
Data read from the Coolant Level sensor is valid but is below normal operating range.

Monitor Operation:
DTC 111.18-SE657
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Key switch is on.

Abort Conditions (any active):


Key switch is off.

Pause Conditions (any active):


111.3-SE572, 111.4-SE283

Malfunction Thresholds (all active):


Coolant Level Sensor Value ≥ 3 V

Cummins Inc. Revision Date: March 30, 2017 211


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

159. 190.0-SE124: Engine Crankshaft Speed/Position - Data Valid But


Above Normal Operating Range - Most Severe Level
Engine Speed too high

Monitor Operation:
DTC 190.0-SE124
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.06 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Engine Speed > 3,600 RPM

Cummins Inc. Revision Date: March 30, 2017 212


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

160. 3222.5-SE5151: Aftertreatment Intake Gas Sensor Heater - Current


Below Normal or Open Circuit
The NOx sensor circuitry has detected a failure affecting the engine outlet NOx sensor heater circuit.
This monitor is used to provide fault isolation for particular circuit continuity failure modes. However, if
the physical failure prevents reaching the enable conditions for this monitor, coverage is still provided
via other diagnostics. For example, 5024.10-SE5245 doesn't require the sensor temperature to reach
any threshold, and thus will provide coverage for heater performance failure modes.

Monitor Operation:
DTC 3222.5-SE5151
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds after sensor identifies any of the
listed malfunction criteria.
MIL Activation Criteria 2 trips

Abort Conditions (any active):


3216.9-SE2487

Pause Conditions (any active):


Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 160 seconds
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) AND engine out NOx sensor
operating temperature >= 800 degC for < 100 seconds.

Malfunction Thresholds (all active):


[Open H-] The resistance between the sensors heater connection to Ground and a 3rd heater
electrode > 1,000,000 ohms for 10 seconds.
or
[Open H+] The resistance between the sensors heater supply and a 3rd heater electrode > 1,000,000
ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 213


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[H+/Tmp] (The voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms) for 40 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[Open Tmp] The resistance between the sensors 3rd electrode within its internal heater is >
1,000,000 ohms for 10 seconds.
or
[M1/M2] (5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode) for 40 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 V for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 214


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 0 ohms for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 215


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

161. 5024.10-SE5246: Aftertreatment 1 Intake NOx Sensor Heater -


Abnormal Rate of Change
Engine Out NOx sensor heater failure.

Monitor Operation:
DTC 5024.10-SE5246
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Amount of time that heater reaches working temperature > 30 sec
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.).

Abort Conditions (any active):


3222.5-SE5151
3216.4-SE5153
3216.9-SE2487
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
NOx sensor supply voltage > 16.5 V
NOx sensor supply voltage < 10.8 V
Exhaust gas velocity ≥ 50 m/sec

Malfunction Thresholds (all active):


Percentage of time spent heating >= 5% of a 60 second diagnostic window.
OR the number of transitions from maintain working temperature to heating >= 5 (counts) in a 60
second diagnostic window.

Cummins Inc. Revision Date: March 30, 2017 216


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 217


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

162. 5024.10-SE5245: Aftertreatment 1 Intake NOx Sensor Heater -


Abnormal Rate of Change
Engine Out NOx Sensor Heater malfunction.

Monitor Operation:
DTC 5024.10-SE5245
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.).

Abort Conditions (any active):


3222.5-SE5151
3216.4-SE5153
3216.9-SE2487
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
NOx sensor supply voltage > 16.5 V
NOx sensor supply voltage < 10.8 V
Exhaust gas velocity ≥ 50 m/sec

Malfunction Thresholds (all active):


Time for heater to reach working temperature of 820 degC after enable conditions are satisfied ≥ 120
sec

Cummins Inc. Revision Date: March 30, 2017 218


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

163. 3218.2-SE5829: Aftertreatment 1 Intake NOx Sensor Power Supply


- Data Erratic, Intermittent, or Incorrect
The engine out NOx sensor circuitry has detected an intermittent power supply voltage drop that results
in a reset internal to the sensor.

Monitor Operation:
DTC 3218.2-SE5829
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 1 seconds

Malfunction Thresholds (all active):


The number of filtered sensor reset events (sensor supply power < 6 V) is greater than 12 counts,
within a diagnostic time window (300 sec) Sensor reset events are "filtered" by ignoring consecutive
reset events occuring within (20 sec).

Cummins Inc. Revision Date: March 30, 2017 219


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

164. 3218.2-SE5152: Aftertreatment 1 Intake NOx Sensor Power Supply


- Data Erratic, Intermittent, or Incorrect
The engine out NOx sensor circuitry has detected that its battery supply voltage is outside the desired
range.

Monitor Operation:
DTC 3218.2-SE5152
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Abort Conditions (any active):


3216.9-SE2487

Pause Conditions (any active):


Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 160 seconds
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) AND engine out NOx sensor
operating temperature >= 800 degC for < 100 seconds.

Malfunction Thresholds (all active):


NOx sensor supply voltage > 16.5 V for 10 seconds.
or NOx sensor supply voltage < 10.8 V for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 220


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

165. 3216.4-SE5153: Aftertreatment 1 Intake NOx Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The NOx sensor circuitry has detected a failure within the engine out NOx sensor's internal circuitry that
causes the sensed NOx value to be suspect. This monitor is used to provide fault isolation for particular
circuit continuity failure modes. However, if the physical failure prevents reaching the enable conditions
for this monitor, coverage is still provided via other diagnostics. For example, 5024.10-SE5245 doesn't
require the sensor temperature to reach any threshold, and thus will provide coverage for heater
performance failure modes.

Monitor Operation:
DTC 3216.4-SE5153
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Abort Conditions (any active):


3216.9-SE2487

Pause Conditions (any active):


Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 160 seconds
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) AND engine out NOx sensor
operating temperature >= 800 degC for < 100 seconds.

Malfunction Thresholds (all active):


[Open P+] The resistance between the electrode on the top of the sensor (directly exposed to exhaust
gas) and ground > 1,000,000 ohms for 10 seconds.
or
[Open Ref] The resistance between the sensors air reference electrode and ground > 1,000,000 ohms
for 10 seconds.
or
[Open M1] The resistance between the sensors pumping electrode in the 2nd chamber and ground >
1,000,000 ohms for 10 seconds.
or
[Open P-] The resistance between the sensors pumping electrode in 1st pumping chamber and
ground > 1,000,000 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 221


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[Ref/M2] (The resistance between the sensors air reference electrode and the sensors measuring
electrode in the 2nd chamber is < 0.5 ohms AND the voltage between the pumping electrode in the
2nd chamber and reference is within 20mV of a 420mV setpoint AND the voltage between the
measuring electrode in the 2nd chamber and the reference < 15mV) for 40 seconds.
or
[P-/M2] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the measuring electrode in the 2nd chamber and
reference) for 40 seconds.
or
[P+/M2] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
measuring electrode within the 2nd chamber is < 0.5 ohms AND the voltage between the measuring
electrode in the 2nd chamber and reference < 120 mV) for 40 seconds.
or
[P-/M1] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the pumping electrode in the 2nd chamber and
reference) for 40 seconds.
or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 1,000,000 ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[H+/Tmp] (the voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms) for 40 seconds.
or
[Ref/H+] The resistance between the air reference electrode and the sensors internal heater supply <
0.5 ohms for 10 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 for 10 seconds.
or
[Ref/H-] The resistance between the air reference electrode and ground < 0.5 ohms for 10 seconds.
or
[Ref/M1] The resistance between the sensors air reference electrode and the sensors pumping
electrode in the 2nd chamber is < 0.5 ohms for 10 seconds.
or
[M1/H+] (The resistance between the pumping electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms AND the the voltage between the electrode in the 1st
chamber and the air reference electrode < 25.6 mV) for 40 seconds.
or
[P+/P-] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 1st chamber is < 0.5 ohms AND | the current entering the pumping
electrode in the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the
2nd chamber and the reference < 100 mV ) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 222


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.
or
[P-/H+] The resistance between the pumping electrode in the 1st chamber and the sensors internal
heater supply is < 0.5 ohms for 10 seconds.
or
[M1/H-] The resistance between the pumping electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M2/H-] The resistance between the measuring electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P-/H-] The resistance between the pumping electrode in the 1st chamber and ground is < 0.5 ohms
for 10 seconds.
or
[M2/H+] The resistance between the measuring electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms for 10 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[P+/M1] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 2nd chamber is < 0.5 ohms AND the binary voltage between the
sensors top electrode and reference < 200 mV AND ((| the current entering the pumping electrode in
the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the 2nd chamber
and the reference < 100 mV) OR (binary voltage between the sensors top electrode and reference =
the voltage between the pumping electrode in the 2nd chamber and reference)) for 40 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 223


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[P+/H-] The resistance between the electrode in on the top of the sensor (exposed to the exhaust gas)
and ground is < 0.5 ohms for 10 seconds.
or
[Ref/P-] (The resistance between the air reference electrode and pumping electrode in the 1st
chamber < 0.5 ohms AND the voltage between the electrode in the 1st chamber and the air reference
electrode < 25.6 mV) for 40 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[M1/M2] (5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 224


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

166. 3216.4-SE7986: Aftertreatment 1 Intake NOx Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The NOx sensor circuitry has detected a failure within the engine out NOx sensor's internal circuitry that
causes the sensed O2 value to be suspect. This monitor is used to provide fault isolation for particular
circuit continuity failure modes. However, if the physical failure prevents reaching the enable conditions
for this monitor, coverage is still provided via other diagnostics. For example, 5024.10-SE5245 doesn't
require the sensor temperature to reach any threshold, and thus will provide coverage for heater
performance failure modes.

Monitor Operation:
DTC 3216.4-SE7986
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Abort Conditions (any active):


3216.9-SE2487

Pause Conditions (any active):


Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 160 seconds
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) AND engine out NOx sensor
operating temperature >= 800 degC for < 100 seconds.

Malfunction Thresholds (all active):


[Open P+] The resistance between the electrode on the top of the sensor (directly exposed to exhaust
gas) and ground > 1,000,000 ohms for 10 seconds.
or
[Open Ref] The resistance between the sensors air reference electrode and ground > 1,000,000 ohms
for 10 seconds.
or
[Open M1] The resistance between the sensors pumping electrode in the 2nd chamber and ground >
1,000,000 ohms for 10 seconds.
or
[Open P-] The resistance between the sensors pumping electrode in 1st pumping chamber and
ground > 1,000,000 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 225


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[Ref/M2] (The resistance between the sensors air reference electrode and the sensors measuring
electrode in the 2nd chamber is < 0.5 ohms AND the voltage between the pumping electrode in the
2nd chamber and reference is within 20mV of a 420mV setpoint AND the voltage between the
measuring electrode in the 2nd chamber and the reference < 15mV) for 40 seconds.
or
[P-/M2] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the measuring electrode in the 2nd chamber and
reference) for 40 seconds.
or
[P+/M2] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
measuring electrode within the 2nd chamber is < 0.5 ohms AND the voltage between the measuring
electrode in the 2nd chamber and reference < 120 mV) for 40 seconds.
or
[P-/M1] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the pumping electrode in the 2nd chamber and
reference) for 40 seconds.
or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 1,000,000 ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[H+/Tmp] (the voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms) for 40 seconds.
or
[Ref/H+] The resistance between the air reference electrode and the sensors internal heater supply <
0.5 ohms for 10 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 for 10 seconds.
or
[Ref/H-] The resistance between the air reference electrode and ground < 0.5 ohms for 10 seconds.
or
[Ref/M1] The resistance between the sensors air reference electrode and the sensors pumping
electrode in the 2nd chamber is < 0.5 ohms for 10 seconds.
or
[M1/H+] (The resistance between the pumping electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms AND the the voltage between the electrode in the 1st
chamber and the air reference electrode < 25.6 mV) for 40 seconds.
or
[P+/P-] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 1st chamber is < 0.5 ohms AND | the current entering the pumping
electrode in the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the
2nd chamber and the reference < 100 mV ) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 226


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.
or
[P-/H+] The resistance between the pumping electrode in the 1st chamber and the sensors internal
heater supply is < 0.5 ohms for 10 seconds.
or
[M1/H-] The resistance between the pumping electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M2/H-] The resistance between the measuring electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P-/H-] The resistance between the pumping electrode in the 1st chamber and ground is < 0.5 ohms
for 10 seconds.
or
[M2/H+] The resistance between the measuring electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms for 10 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[P+/M1] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 2nd chamber is < 0.5 ohms AND the binary voltage between the
sensors top electrode and reference < 200 mV AND ((| the current entering the pumping electrode in
the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the 2nd chamber
and the reference < 100 mV) OR (binary voltage between the sensors top electrode and reference =
the voltage between the pumping electrode in the 2nd chamber and reference)) for 40 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 227


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[P+/H-] The resistance between the electrode in on the top of the sensor (exposed to the exhaust gas)
and ground is < 0.5 ohms for 10 seconds.
or
[Ref/P-] (The resistance between the air reference electrode and pumping electrode in the 1st
chamber < 0.5 ohms AND the voltage between the electrode in the 1st chamber and the air reference
electrode < 25.6 mV) for 40 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[M1/M2] (5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 228


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

167. 723.2-SE422: Engine Camshaft Speed/Position Sensor - Data


Erratic, Intermittent, or Incorrect
Monitor the camshaft tooth edge pulse signal for intermittent unexpected sync tooth.

Monitor Operation:
DTC 723.2-SE422
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 rev
MIL Activation Criteria 2 trips

Entry Conditions (all active):


723.2-SE415, 723.2-SE45
Camshaft tooth edge is detected.
Engine speed > 1,200 RPM

Pause Conditions (any active):


723.2-SE415, 723.2-SE45
Engine speed ≤ 1,200 RPM
Camshaft tooth edge is not detected.

Malfunction Thresholds (all active):


Camshaft sync tooth, as detected by the camshaft sensor, doesn't match the expected sync tooth
location at most once every 2 camshaft revolutions.

Cummins Inc. Revision Date: March 30, 2017 229


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

168. 723.2-SE415: Engine Camshaft Speed/Position Sensor - Data


Erratic, Intermittent, or Incorrect
Monitor the tooth edge pulse signal for loss of pulses from the engine camshaft sensor.

Monitor Operation:
DTC 723.2-SE415
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


3510.3-SE119, 3510.4-SE101
Engine speed ≤ 100 RPM
Crankshaft tooth edge is not detected.

Malfunction Thresholds (all active):


(If Engine speed >= 100 rpm and < 200 rpm, amount of time since a pulse was seen on camshaft
sensor > 0.4 sec) OR
(If Engine speed >= 200 rpm and < 400 rpm, amount of time since a pulse was seen on camshaft
sensor > 0.2 sec) OR
(If Engine speed >= 400 rpm, amount of time since a pulse was seen on camshaft sensor > 0.1 sec)

Cummins Inc. Revision Date: March 30, 2017 230


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

169. 723.2-SE45: Engine Camshaft Speed/Position Sensor - Data Erratic,


Intermittent, or Incorrect
Monitor the tooth edge pulse signal for the missing sync tooth expected from the engine camshaft
sensor.

Monitor Operation:
DTC 723.2-SE45
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Engine Speed ≤ 100 RPM

Malfunction Thresholds (all active):


Absence of Sync tooth pulse in the generated pulse signal waveform from the camshaft sensor, when
Engine speed > 100 RPM

Cummins Inc. Revision Date: March 30, 2017 231


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

170. 190.11-SE460: Engine Speed - Root Cause Not Known


Monitor the tooth edge pulse signal for complete loss of pulses from the engine crankshaft and
camshaft sensors.

Monitor Operation:
DTC 190.11-SE460
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 40 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Engine is not stopped, for > 2 sec

Pause Conditions (any active):


Engine is stopped, for > 2 sec

Malfunction Thresholds (all active):


(Crankshaft pulse signals are not detected OR Crankshaft sync signal is not detected OR Camshaft half
cycle is unknown)
(Camshaft pulse signals are not detected OR Camshaft sync signal is not detected OR Engine is turning
in the reverse direction)
At least one of the two sensors (crankshaft sensor and camshaft sensor) has pulse signal

Cummins Inc. Revision Date: March 30, 2017 232


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

171. 190.2-SE419: Engine Crankshaft Speed/Position - Data Erratic,


Intermittent, or Incorrect
Monitor the crankshaft tooth edge pulse signal for intermittent unexpected sync gap.

Monitor Operation:
DTC 190.2-SE419
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 rev
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.2-SE417, 190.2-SE54
Crankshaft tooth edge is detected.
Engine speed > 1,200 RPM

Pause Conditions (any active):


190.2-SE417, 190.2-SE54
Engine speed ≤ 1,200 RPM
Crankshaft tooth edge is not detected.

Malfunction Thresholds (all active):


Crankshaft tooth gap, as detected by the crankshaft sensor, doesn't match the expected sync gap
location at most once every 2 crankshaft revolutions.

Cummins Inc. Revision Date: March 30, 2017 233


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

172. 190.2-SE417: Engine Crankshaft Speed/Position - Data Erratic,


Intermittent, or Incorrect
Monitor the tooth edge pulse signal for loss of pulses from the engine crankshaft sensor.

Monitor Operation:
DTC 190.2-SE417
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


3511.3-SE814, 3511.4-SE816
Engine speed ≤ 100 RPM
Camshaft tooth edge is not detected.

Malfunction Thresholds (all active):


(If Engine speed >= 100 rpm and < 200 rpm, amount of time since a pulse was seen on crankshaft
sensor > 0.5 sec) OR
(If Engine speed >= 200 rpm and < 400 rpm, amount of time since a pulse was seen on crankshaft
sensor > 0.25 sec) OR
(If Engine speed >= 400 rpm, amount of time since a pulse was seen on crankshaft sensor > 0.125
sec)

Cummins Inc. Revision Date: March 30, 2017 234


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

173. 190.2-SE54: Engine Crankshaft Speed/Position - Data Erratic,


Intermittent, or Incorrect
Monitor the tooth edge pulse signal for the sync gap (2 missing teeth) pulse expected from the engine
crankshaft sensor.

Monitor Operation:
DTC 190.2-SE54
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Engine Speed ≤ 100 RPM

Malfunction Thresholds (all active):


Absence of an expected synchronization gap in the generated pulse signal waveform from the
crankshaft sensor.

Cummins Inc. Revision Date: March 30, 2017 235


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

174. 636.8-SE12594: Engine Position Sensor - Abnormal Frequency or


Pulse Width or Period
The fault is active if a bi-directional sensor is installed instead of unidirectional sensor or a
malfunctioning unidirectional sensor

Monitor Operation:
DTC 636.8-SE12594
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


190.2-SE417, 190.2-SE419, 190.2-SE54
Engine speed > 100 RPM

Pause Conditions (any active):


190.2-SE417, 190.2-SE419, 190.2-SE54
Engine speed ≤ 100 RPM

Malfunction Thresholds (all active):


Engine speed signal pulse width >= 83 uSec AND Engine speed signal pulse width <= 97 uSec
OR
Engine speed signal pulse width >= 38 uSec AND Engine speed signal pulse width <= 52 uSec

Cummins Inc. Revision Date: March 30, 2017 236


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

175. 723.7-SE389: Engine Speed/Position Camshaft and Crankshaft


Misalignment - Mechanical System Not Responding or Out of
Adjustment
Monitor tooth edge pulse signals to detect a phase misalignment betweeen the engine crankshaft and
camshaft targets.

Monitor Operation:
DTC 723.7-SE389
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 rev
MIL Activation Criteria 1 trip

Pause Conditions (any active):


Engine Speed ≤ 100 RPM
Engine Speed > 1,200 RPM

Malfunction Thresholds (all active):


(Detected backup sync tooth location - expected backup sync tooth location < -1 counts) OR
(Detected backup sync tooth location - expected backup sync tooth location > 1 counts)

Cummins Inc. Revision Date: March 30, 2017 237


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

176. 5357.31-SE8483: Engine Fuel Injection Quantity Error for Multiple


Cylinders - Condition Exists
Detect equally failed injectors fueling error when the estimated injector fuel quantity for all the injectors
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 5357.31-SE8483
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 238


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
SCR Thermal Management mode (more information available in AECD 13-2).
Normal Mode
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


For all the injectors, ( (Estimated Average Fuel Quantity Deviation >= 3 )mg/stroke) OR ( (Estimated
Average Fuel Quantity Deviation <= -6) mg/stroke) Where: Estimated Average Fuel Quantity Deviation
is calculated by taking sample measurement for each injector during engine motoring condition and
by averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is reseted back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 239


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

177. 1209.2-SE3924: Exhaust Gas Pressure 1 - Data Erratic, Intermittent,


or Incorrect
Exhaust Pressure Sensor reading is In Range High

Monitor Operation:
DTC 1209.2-SE3924
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 90 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):

Pause Conditions (any active):


1209.2-SE4442
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494,
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-SE485, 411.4-
SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
1209.3-SE493, 1209.4-SE494
Engine is not in Run State.
VGT Position > 80 %
Fueling < 15 mg/stroke
EGR Off Engine Protection is active

Malfunction Thresholds (all active):


Average of (Exhaust Pressure - Estimated Exhaust Pressure) over a 90 second period is ever ≥ 76.111
kPa Diagnostic Tolerance = 0 kPa (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 240


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

178. 1209.2-SE3922: Exhaust Gas Pressure 1 - Data Erratic, Intermittent,


or Incorrect
Exhaust Pressure Sensor reading is In Range Low

Monitor Operation:
DTC 1209.2-SE3922
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 90 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):

Pause Conditions (any active):


1209.2-SE4442
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494,
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988, 411.2-SE1911, 411.3-SE485, 411.4-
SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
1209.3-SE493, 1209.4-SE494
Engine is not in Run State.
VGT Position > 80 %
Fueling < 15 mg/stroke
EGR Off Engine Protection is active

Malfunction Thresholds (all active):


Average of (Estimated Exhuast Pressure - Exhaust Pressure) over a 90 second period is ever ≥ 76.111
kPa Diagnostic Tolerance = 0 kPa (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 241


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

179. 1209.2-SE4442: Exhaust Gas Pressure 1 - Data Erratic, Intermittent,


or Incorrect
Exhaust Pressure Sensor reading is erratic, intermittent or incorrect at keyoff.

Monitor Operation:
DTC 1209.2-SE4442
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine is in stopped state
The time since Key Switch is turned OFF ≥ 52 sec

Abort Conditions (any active):


1209.3-SE493, 1209.4-SE494
Coolant Temperature ≤ 70 °C

Malfunction Thresholds (all active):


|Exhaust Pressure - the most accurate pressure sensor from the remaining pressure sensor| > (27.69
kPa(absolute) + the tolerance of the most accurate pressure sensor from the remaining pressure
sensors)
|Exhaust Pressure - the second most accurate pressure sensor from the remaining pressure sensor| >
(27.69 kPa(absolute) + the tolerance of the second most accurate pressure sensor from the remaining
pressure sensors)
| the most accurate sensor from the remaining pressure sensors - the second most accurate sensor
from the remaining pressure sensors | < (the tolerance of the most accurate sensor from the
remaining pressure sensors + the tolerance of the second most accurate sensor from the remaining
pressure sensors)
The tolerance of the remaining pressure sensors are:
Charge Pressure sensor tolerance = 11.84 kPa(absolute)
Compressor Inlet Pressure sensor tolerance = 3.19 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 242


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

180. 1209.3-SE493: Exhaust Gas Pressure Sensor 1 Circuit - Voltage


Above Normal or Shorted to High Source
Exhaust Pressure sensor reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 1209.3-SE493
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Exhaust Pressure sensor value > 4.75V (620.52 kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 243


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

181. 1209.4-SE494: Exhaust Gas Pressure Sensor 1 Circuit - Voltage


Below Normal or Shorted to Low Source
Exhaust Pressure sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 1209.4-SE494
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Exhaust Pressure sensor value < 0.25V (44.78 kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 244


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

182. 647.4-SE1003: Fan Control Circuit - Voltage Below Normal or


Shorted to Low Source
Fan Clutch driver voltage has its voltage below normal, or shorted to a low source

Monitor Operation:
DTC 647.4-SE1003
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Fan Clutch Driver and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 245


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

183. 647.3-SE1004: Fan Control Circuit - Voltage Above Normal or


Shorted to High Source
Fan Clutch driver voltage is above voltage limit.

Monitor Operation:
DTC 647.3-SE1004
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Fan Clutch Driver and ground > 500,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 246


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

184. 96.3-SE3946: Fuel Level (Main Tank) Sensor Circuit - Voltage Above
Normal or Shorted to High Source
Fuel Level Sensor ouput value is above operational limit.

Monitor Operation:
DTC 96.3-SE3946
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10.00000 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Fuel Level Sensor Value > 4.75 V (100 % )

Cummins Inc. Revision Date: March 30, 2017 247


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

185. 96.4-SE3947: Fuel Level (Main Tank) Sensor Circuit - Voltage Below
Normal or Shorted to Low Source
Fuel Level Sensor ouput value is below operational limit.

Monitor Operation:
DTC 96.4-SE3947
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10.00000 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Fuel Level Sensor Value < 0.25 V (0 %)

Cummins Inc. Revision Date: March 30, 2017 248


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

186. 157.7-SE7212: Injector Metering Rail 1 Pressure - Mechanical


System Not Responding or Out of Adjustment
Detect pressure rationality error of the second output of the dual output fuel pressure sensor when the
sensor's output 2 cycle length reaches the calibrated termination threshold and the second fuel pressure
output is within the out-of-range limits or the sensor's output 2 cycle length is out of the specified
normal range.

Monitor Operation:
DTC 157.7-SE7212
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 9 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


1349.3-SE6690
1349.4-SE6691

Pause Conditions (any active):


1349.3-SE6690
1349.4-SE6691

Malfunction Thresholds (all active):


(fuel pressure output 2 cycle length = 520 msec) AND (0.25 V ≤ the second fuel pressure output ≤
4.815 V) OR fuel pressure output 2 cycle length ≤ 210 msec OR 520 msec > fuel pressure output 2
cycle length ≥ 310 msec

Cummins Inc. Revision Date: March 30, 2017 249


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

187. 5585.18-SE8369: Engine Injector Metering Rail 1 Cranking Pressure


- Data Valid But Below Normal Operating Range - Moderately
Severe Level
Fuel pressure is below a calibrated threshold when the Engine is Cranking

Monitor Operation:
DTC 5585.18-SE8369
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 40 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


157.3-SE525, 157.4-SE526
157.7-SE7209, 157.7-SE7211
1347.3-SE965, 1347.4-SE966
Engine Speed > 80 RPM
Ambient Air temperature ≥ -6.7 °C
Fuel Pressure Command > 170 bar
RefTable28.4 - Pump Flow Command ≤ 0.5 g/sec

Pause Conditions (any active):


157.3-SE525, 157.4-SE526
157.7-SE7209, 157.7-SE7211
1347.3-SE965, 1347.4-SE966
Engine Speed ≤ 80 RPM
Ambient Air temperature < -6.7 °C
RefTable28.4 - Pump Flow Command > 0.5 g/sec
Fuel Pressure Command ≤ 170 bar

Malfunction Thresholds (all active):


Fuel Pressure ≤ 150 bar

Cummins Inc. Revision Date: March 30, 2017 250


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

188. 157.7-SE7209: Injector Metering Rail 1 Pressure - Mechanical


System Not Responding or Out of Adjustment
Detect fuel pressure rationality high error by comparing the first fuel pressure signal to the second fuel
pressure signal.

Monitor Operation:
DTC 157.7-SE7209
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 11 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


157.3-SE525
157.4-SE526
1349.3-SE6690
1349.4-SE6691
157.7-SE7212
The absolute change of the first fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 ≤ 200 bar
The absolute change of the second fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 ≤ 200 bar
The pressure signal1 raw data and the pressure signal2 raw data are both valid. Where: A valid
pressure signal is defined by inspection of the periodic signal received from the sensor; cycle length
between (213.5ms to 311.5ms) and transition from high voltage (> ~96% of supply) to low voltage (<
~4% of supply).

Pause Conditions (any active):


157.3-SE525
157.4-SE526
1349.3-SE6690
1349.4-SE6691
157.7-SE7212
The absolute change of the first fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 > 200 bar
The absolute change of the second fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 > 200 bar
The pressure signal1 raw data or the pressure signal2 raw data is invaild or both are invalid. Where: A
valid pressure signal is defined by inspection of the periodic signal received from the sensor; cycle
length between (213.5ms to 311.5ms) and transition from high voltage (> ~96% of supply) to low
voltage (< ~4% of supply).

Cummins Inc. Revision Date: March 30, 2017 251


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


The first fuel pressure output - the second fuel pressure output > 105 bar

Cummins Inc. Revision Date: March 30, 2017 252


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

189. 157.7-SE7211: Injector Metering Rail 1 Pressure - Mechanical


System Not Responding or Out of Adjustment
Detect fuel pressure rationality low error by comparing the first fuel pressure signal to the second fuel
pressure signal.

Monitor Operation:
DTC 157.7-SE7211
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 11 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


157.3-SE525
157.4-SE526
1349.3-SE6690
1349.4-SE6691
157.7-SE7212
The absolute change of the first fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 ≤ 200 bar
The absolute change of the second fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 ≤ 200 bar
The pressure signal1 raw data and the pressure signal2 raw data are both valid. Where: A valid
pressure signal is defined by inspection of the periodic signal received from the sensor; cycle length
between (213.5ms to 311.5ms) and transition from high voltage (> ~96% of supply) to low voltage (<
~4% of supply).

Pause Conditions (any active):


157.3-SE525
157.4-SE526
1349.3-SE6690
1349.4-SE6691
157.7-SE7212
The absolute change of the first fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 > 200 bar
The absolute change of the second fuel pressure output between 2 consecutive cycles of the fuel
pressure sensor's output 2 > 200 bar
The pressure signal1 raw data or the pressure signal2 raw data is invaild or both are invalid. Where: A
valid pressure signal is defined by inspection of the periodic signal received from the sensor; cycle
length between (213.5ms to 311.5ms) and transition from high voltage (> ~96% of supply) to low
voltage (< ~4% of supply).

Cummins Inc. Revision Date: March 30, 2017 253


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


The first fuel pressure output - the second fuel pressure output < -105 bar

Cummins Inc. Revision Date: March 30, 2017 254


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

190. 729.3-SE665: Engine Intake Air Heater 1 Circuit - Voltage Above


Normal or Shorted to High Source
The Grid Heater Driver ECM feedback resistance is higher than expected.

Monitor Operation:
DTC 729.3-SE665
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Grid Heater Driver is On

Malfunction Thresholds (all active):


Resistance between the Grid Heater Driver and ground > 500,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 255


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

191. 729.4-SE668: Engine Intake Air Heater 1 Circuit - Voltage Below


Normal or Shorted to Low Source
The Grid Heater Driver feedback resistance is lower than expected.

Monitor Operation:
DTC 729.4-SE668
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Grid Heater Driver is Off

Malfunction Thresholds (all active):


Resistance between the Grid Heater Driver and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 256


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

192. 110.31-SE2141: Engine Coolant Temperature - Condition Exists


High Coolant temperature.

Monitor Operation:
DTC 110.31-SE2141
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Abort Conditions (any active):

Pause Conditions (any active):


Engine is not Running

Malfunction Thresholds (all active):


Coolant Temperature >= 110 Deg C

Cummins Inc. Revision Date: March 30, 2017 257


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

193. 3464.3-SE12370: Electronic Throttle Control Actuator Driver Circuit


- Voltage Above Normal or Shorted to High Source
The ECM monitors whether the H-Bridge circuit that drives an Intake Air Throttle actuator motor is
shorted to a high voltage source.

Monitor Operation:
DTC 3464.3-SE12370
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through low-side switches of Intake Air Throttle H-Bridge circuit > 5 A

Cummins Inc. Revision Date: March 30, 2017 258


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

194. 3464.4-SE12371: Electronic Throttle Control Actuator Driver Circuit


- Voltage Below Normal or Shorted to Low Source
The ECM monitors whether the H-Bridge circuit that drives an Intake Air Throttle actuator motor is
shorted to a low voltage source.

Monitor Operation:
DTC 3464.4-SE12371
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through high-side switches of Intake Air Throttle H-Bridge circuit > 18 A

Cummins Inc. Revision Date: March 30, 2017 259


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

195. 3464.3-SE12372: Electronic Throttle Control Actuator Driver Circuit


- Voltage Above Normal or Shorted to High Source
The ECM monitors whether the H-Bridge circuit that drives an Intake Air Throttle actuator motor has an
open-load condition.

Monitor Operation:
DTC 3464.3-SE12372
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Current through low-side switches of Intake Air Throttle H-Bridge circuit < 40 mA while being driven
by a nonzero PWM signal

Cummins Inc. Revision Date: March 30, 2017 260


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

196. 51.2-SE4014: Engine Intake Throttle Actuator Position Sensor -


Data Erratic, Intermittent, or Incorrect
The Intake Air Throttle valve position feedback value is In Range, High.

Monitor Operation:
DTC 51.2-SE4014
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 15 sec
MIL Activation Criteria 1 trip

Pause Conditions (any active):


3464.3-SE12370
3464.4-SE12371
3464.3-SE12372
Intake air throttle actuator is in PWM-Off state.

Malfunction Thresholds (all active):


Average of (IAT HB Position - IAT HB Position Command) over a 15 second period is ever > 20%
Diagnostic Tolerance = 0% (Please refer to the CUSUM Supplement in Section C for further details)

Cummins Inc. Revision Date: March 30, 2017 261


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

197. 51.2-SE4015: Engine Intake Throttle Actuator Position Sensor -


Data Erratic, Intermittent, or Incorrect
The Intake Air Throttle valve position feedback value is In Range, Low.

Monitor Operation:
DTC 51.2-SE4015
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 15 sec
MIL Activation Criteria 1 trip

Pause Conditions (any active):


3464.3-SE12370
3464.4-SE12371
3464.3-SE12372
Intake air throttle actuator is in PWM-Off state.

Malfunction Thresholds (all active):


Average of (IAT HB Position Command - IAT HB Position) over a 15 second period is ever > 20 %
Diagnostic Tolerance = 0 % (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 262


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

198. 51.3-SE3530: Engine Intake Throttle Actuator Position Sensor


Circuit - Voltage Above Normal or Shorted to High Source
Intake Air Throttle valve position is greater than specified operating range for a calibrated amount of
time.

Monitor Operation:
DTC 51.3-SE3530
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Measured Intake Air Throttle Valve Position > 4.846 V (110.809 %)

Cummins Inc. Revision Date: March 30, 2017 263


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

199. 51.4-SE3529: Engine Intake Throttle Actuator Position Sensor


Circuit - Voltage Below Normal or Shorted to Low Source
Intake Air Throttle valve position is less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 51.4-SE3529
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Measured Intake Air Throttle Valve Position < 0.176 V (-16.621 %)

Cummins Inc. Revision Date: March 30, 2017 264


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

200. 5395.18-SE3783: Engine Idle Fuel Quantity - Data Valid But Below
Normal Operating Range - Moderately Severe Level
Idle Fuel lower than the nominal fueling at idle.

Monitor Operation:
DTC 5395.18-SE3783
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 15 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine State is Run and not Stop/Crank/Brake/Shutdown
Idle Reference Speed ≤ 900 RPM
Vehicle Speed ≤ 0 mph
Fueling is controlled by a governor requesting a lower bound on Engine Speed
PTO is not active
Current Idle Reference Speed (Target) is the same as previous Idle Reference (verifies reference
speed is not changing).

Abort Conditions (any active):


2623.3-SE1378, 2623.4-SE1379, 91.2-SE1380, 91.2-SE3200, 91.3-SE63, 91.4-SE64
110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
84.2-SE130, 84.2-SE4360, 84.2-SE4361
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
1322.31-SE2350, 1323.31-SE2344, 1324.31-SE2346, 1325.31-SE2347, 1326.31-SE2345, 1327.31-
SE2348, 1328.31-SE2349, 157.16-SE522, 157.18-SE523

Pause Conditions (any active):


Engine State is not Run
Idle Reference Speed > 900 RPM
Vehicle Speed > 0 mph
Fueling is controlled by a governor that does not request a lower bound on Engine Speed
PTO Status is active
Current Idle Reference Speed (Target Speed) is not the same as previous Idle Reference

Malfunction Thresholds (all active):


Idle Fuel < 2 mg/stroke

Cummins Inc. Revision Date: March 30, 2017 265


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 266


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

201. 188.16-SE3775: Engine Speed At Idle - Data Valid But Above


Normal Operating Range - Moderately Severe Level
Engine Speed at Idle lies outside the acceptable boundary of nominal Idle speed and tends to run above
nominal Idle speed.

Monitor Operation:
DTC 188.16-SE3775
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine State is Run and not Stop/Crank/Brake/Shutdown
Idle Reference Speed ≤ 900 RPM
Vehicle Speed ≤ 0 mph
Fueling is controlled by a governor requesting a lower bound on Engine Speed
PTO is not active
Current Idle Reference Speed (Target) is the same as previous Idle Reference (verifies reference speed
is not changing).

Abort Conditions (any active):


2623.3-SE1378, 2623.4-SE1379, 91.2-SE1380, 91.2-SE3200, 91.3-SE63, 91.4-SE64
110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
84.2-SE130, 84.2-SE4360, 84.2-SE4361
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
1322.31-SE2350, 1323.31-SE2344, 1324.31-SE2346, 1325.31-SE2347, 1326.31-SE2345, 1327.31-
SE2348, 1328.31-SE2349, 157.16-SE522, 157.18-SE523

Pause Conditions (any active):


Engine State is not Run
Idle Reference Speed > 900 RPM
Vehicle Speed > 0 mph
Fueling is controlled by a governor that does not request a lower bound on Engine Speed
PTO Status is active
Current Idle Reference Speed (Target Speed) is not the same as previous Idle Reference

Malfunction Thresholds (all active):


Engine Speed - Idle Reference Speed > 50 RPM, when the amount of time that engine speed is outside
the idle reference speed band, by more than 50 RPM, is equal to 15 seconds.

Cummins Inc. Revision Date: March 30, 2017 267


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 268


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

202. 188.18-SE3781: Engine Speed At Idle - Data Valid But Below


Normal Operating Range - Moderately Severe Level
Engine Speed at Idle lies outside the acceptable boundary of nominal Idle speed and tends to run below
nominal Idle speed.

Monitor Operation:
DTC 188.18-SE3781
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine State is Run and not Stop/Crank/Brake/Shutdown
Idle Reference Speed ≤ 900 RPM
Vehicle Speed ≤ 0 mph
Fueling is controlled by a governor requesting a lower bound on Engine Speed
PTO is not active
Current Idle Reference Speed (Target) is the same as previous Idle Reference (verifies reference speed
is not changing).

Abort Conditions (any active):


2623.3-SE1378, 2623.4-SE1379, 91.2-SE1380, 91.2-SE3200, 91.3-SE63, 91.4-SE64
110.2-SE3668, 110.2-SE3669, 110.2-SE3805, 110.3-SE75, 110.4-SE76
84.2-SE130, 84.2-SE4360, 84.2-SE4361
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
1322.31-SE2350, 1323.31-SE2344, 1324.31-SE2346, 1325.31-SE2347, 1326.31-SE2345, 1327.31-
SE2348, 1328.31-SE2349, 157.16-SE522, 157.18-SE523

Pause Conditions (any active):


Engine State is not Run
Idle Reference Speed > 900 RPM
Vehicle Speed > 0 mph
Fueling is controlled by a governor that does not request a lower bound on Engine Speed
PTO Status is active
Current Idle Reference Speed (Target Speed) is not the same as previous Idle Reference

Malfunction Thresholds (all active):


Idle Reference Speed - Engine Speed > 50 RPM, when the amount of time that engine speed is outside
the idle reference speed band, by more than 50 RPM, is equal to 15 seconds.

Cummins Inc. Revision Date: March 30, 2017 269


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 270


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

203. 105.16-SE649: Intake Manifold 1 Temperature - Data Valid But


Above Normal Operating Range - Moderately Severe Level
intake Manifold Temperature above allowed engine operating range.

Monitor Operation:
DTC 105.16-SE649
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Pause Conditions (any active):


105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-SE488
Engine Speed < 650 RPM

Malfunction Thresholds (all active):


Intake Manifold Temperature ≥ 132.219 °C

Cummins Inc. Revision Date: March 30, 2017 271


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

204. 105.15-SE648: Intake Manifold 1 Temperature - Data Valid But


Above Normal Operating Range - Least Severe Level
intake Manifold Temperature above normal engine operating range

Monitor Operation:
DTC 105.15-SE648
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine Speed ≥ 650 RPM

Pause Conditions (any active):


105.2-SE3793, 105.2-SE4070, 105.3-SE487, 105.4-SE488
Engine Speed < 650 RPM

Malfunction Thresholds (all active):


Intake Manifold Temperature ≥ 121.109 °C

Cummins Inc. Revision Date: March 30, 2017 272


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

205. 5246.16-SE5737: Aftertreatment SCR Operator Inducement


Severity - Data Valid But Above Normal Operating Range -
Moderately Severe Level
Active alternate Moderate Driver Inducement (see AECD Document section 7-1 and Appendix VI).

Monitor Operation:
DTC 5246.16-SE5737
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Variable (see AECD document)
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


One or more conditions exist requiring Moderate Driver Inducement (see AECD Document section 7-1
and Appendix VI)

Cummins Inc. Revision Date: March 30, 2017 273


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

206. 1569.15-SE5408: Engine Protection Torque Derate - Data Valid But


Above Normal Operating Range - Least Severe Level
Active Moderate Driver Inducement (see AECD Document section 7-1 and Appendix VI).

Monitor Operation:
DTC 1569.15-SE5408
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Variable (see AECD document)
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


One or more conditions exist requiring Moderate Driver Inducement (see AECD Document section 7-1
and Appendix VI)

Cummins Inc. Revision Date: March 30, 2017 274


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

207. 3695.2-SE6976: Aftertreatment Regeneration Inhibit Switch - Data


Erratic, Intermittent, or Incorrect
Regeneration of the DPF, triggered due to estimated high soot load, is prohibited due to DPF
Regeneration Inhibit Switch physically stuck on

Monitor Operation:
DTC 3695.2-SE6976
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Estimated soot load > 7.75 g/L
DPF Regeneration Inhibit Switch is actively engaged.

Cummins Inc. Revision Date: March 30, 2017 275


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

208. 3703.31-SE5571: Aftertreatment Regeneration Inhibited Due to


Inhibit Switch - Condition Exists
Active regeneration of the DPF prohibited due to regeneration inhibit switch. Regeneration triggers
selected by calibration.

Monitor Operation:
DTC 3703.31-SE5571
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Engine running condition (See RefCond368.1.)
Enable Solid Lamp based on regeneration of DPF trigger states. (See RefCond486.1.)
DPF Regeneration Inhibit Switch in Inhibit State.

Abort Conditions (any active):


NOT Enable Solid Lamp based on regeneration of DPF trigger states. (See RefCond486.1.)

Malfunction Thresholds (all active):


Time elapsed since active regeneration trigger is active > 8 hr

Cummins Inc. Revision Date: March 30, 2017 276


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

209. 729.5-SE7368: Engine Intake Air Heater 1 Circuit - Current Below


Normal or Open Circuit
The error is set if the ratio of the voltage drop, that occurs as Grid Heater turns on compared to the
voltage drop during engine crank, is less than a calibratable threshold.

Monitor Operation:
DTC 729.5-SE7368
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Grid Heater is active and Engine Speed is zero

Abort Conditions (any active):


729.3-SE665, 729.4-SE668
Battery Voltage < 10 V
Battery Voltage > 13 V
|Grid On Delta Voltage - Grid Off Delta Voltage| ≥ 0.55 V
Currently observed Grid ON Battery Voltage - Minimum measured Grid ON Battery Voltage > 0.27 V
Maximum measured Grid ON Battery Voltage - Currently observed Grid ON Battery Voltage > 0.44 V

Malfunction Thresholds (all active):


Grid Heater Degradation < 0.1 (ratio)

Cummins Inc. Revision Date: March 30, 2017 277


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

210. 1267.4-SE997: Idle Shutdown Vehicle Accessories Relay Driver


Circuit - Voltage Below Normal or Shorted to Low Source
Idle Shutdown Relay driver voltage is below voltage limit or shorted to a low source

Monitor Operation:
DTC 1267.4-SE997
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Idle Shutdown Relay driver and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 278


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

211. 1267.3-SE998: Idle Shutdown Vehicle Accessories Relay Driver


Circuit - Voltage Above Normal or Shorted to High Source
Idle Shutdown Relay driver voltage is above voltage limit

Monitor Operation:
DTC 1267.3-SE998
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Idle Shutdown Relay driver and ground > 500,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 279


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

212. 651.5-SE916: Injector Solenoid Driver Cylinder 1 Circuit - Current


Below Normal or Open Circuit
Detect injector 1 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 651.5-SE916
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 1 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 1 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 280


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

213. 652.5-SE917: Injector Solenoid Driver Cylinder 2 Circuit - Current


Below Normal or Open Circuit
Detect injector 2 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 652.5-SE917
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 2 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 2 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 281


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

214. 653.5-SE918: Injector Solenoid Driver Cylinder 3 Circuit - Current


Below Normal or Open Circuit
Detect injector 3 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 653.5-SE918
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 3 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 3 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 282


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

215. 654.5-SE919: Injector Solenoid Driver Cylinder 4 Circuit - Current


Below Normal or Open Circuit
Detect injector 4 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 654.5-SE919
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 4 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 4 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 283


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

216. 655.5-SE920: Injector Solenoid Driver Cylinder 5 Circuit - Current


Below Normal or Open Circuit
Detect injector 5 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 655.5-SE920
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 5 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 5 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 284


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

217. 656.5-SE921: Injector Solenoid Driver Cylinder 6 Circuit - Current


Below Normal or Open Circuit
Detect injector 6 circuit errors when Fuel System ASIC (Application Specific Integrated Circuit) reports
errors in the fault registers

Monitor Operation:
DTC 656.5-SE921
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.34 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Injector 6 was commanded non-zero fueling during last engine cycle

Pause Conditions (any active):


Injector 6 was commanded zero fueling during last engine cycle

Malfunction Thresholds (all active):


If any of the following conditions exists
Microprocessor signal pulse to injector low side driver stuck on > 32.64ms
Inactive short to ground Prior to turn on (high side voltage feedback input low prior to injection ready
state)
Open load / short to battery during injection ready state (the high side voltage feedback input is high
upon the transition from ready to start of injection (SOI) state)
Load current reached hold level during ready state (measured load current >= 11 A during injection
ready state)
Load current reached peak level too quickly (measured load current >= 23.801 A within 16us at the
beginning of the start-of-injection (SOI) state)
Load current did not reach hold level during start of injection (SOI) state (measured load current < 11
A within 256us during SOI)
Battery overvoltage (battery voltage sampled by ECM > 42 V)
Low side overcurrent (measured low side current > 42 A when low side is turned on)
High side overcurrent (measured high side current > 41 A when high side is turned on)
Boost supply overvoltage (measured boost supply voltage > 90 V)
Boost supply overcurrent (measured boost supply current > 49 A when boost supply output is turned
on)

Cummins Inc. Revision Date: March 30, 2017 285


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

218. 639.9-SE1848: SAE J1939 Datalink - Abnormal Update Rate


Determine when the Auxiliary Accel datalink message is not received as expected.

Monitor Operation:
DTC 639.9-SE1848
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 110 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Previous auxiliary accel message requested control of engine.
Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 286


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

219. 639.13-SE747: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Accelerator Interlock Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE747
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 287


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

220. 639.9-SE718: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Accelerator Interlock Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE718
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 288


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

221. 91.13-SE748: SAE J1939 Multiplexed Accelerator Pedal or Lever


Sensor System - Out of Calibration
Signal received for Accelerator Pedal Position does not meet requirements

Monitor Operation:
DTC 91.13-SE748
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 289


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

222. 91.9-SE712: SAE J1939 Multiplexed Accelerator Pedal or Lever


Sensor System - Abnormal Update Rate
Determine when the Accelerator Pedal Position signal is not received on the Datalink

Monitor Operation:
DTC 91.9-SE712
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 260 msec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 290


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

223. 1590.2-SE7559: Adaptive Cruise Control Mode - Data Erratic,


Intermittent, or Incorrect
Determine when the J1939 Adaptive Cruise Control1 message is not received on the Datalink

Monitor Operation:
DTC 1590.2-SE7559
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 291


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

224. 639.13-SE749: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for AC High Pressure Fan Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE749
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 292


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

225. 639.9-SE714: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the AC High Pressure Fan Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE714
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 293


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

226. 1590.2-SE1792: Adaptive Cruise Control Mode - Data Erratic,


Intermittent, or Incorrect
Determine when the Adaptive Cruise Control Mode signal received in Adaptive Cruise Control 1 message
indicates error.

Monitor Operation:
DTC 1590.2-SE1792
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)
Adaptive Cruise Control is currently allowed

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]
Adaptive Cruise Control is currently not allowed

Malfunction Thresholds (all active):


Adaptive Cruise Control device has reported an internal error condition exists.

Cummins Inc. Revision Date: March 30, 2017 294


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

227. 91.13-SE750: SAE J1939 Multiplexed Accelerator Pedal or Lever


Sensor System - Out of Calibration
Signal received for Accelerator Pedal 1 Low Idle Switch does not meet requirements

Monitor Operation:
DTC 91.13-SE750
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 295


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

228. 558.19-SE5333: Accelerator Pedal or Lever Idle Validation Switch -


Received Network Data in Error
Signal received for Accelerator Pedal 1 Low Idle Switch indicates error.

Monitor Operation:
DTC 558.19-SE5333
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Signal indicates J1939 Error Code

Cummins Inc. Revision Date: March 30, 2017 296


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

229. 558.9-SE709: Accelerator Pedal or Lever Idle Validation Switch -


Abnormal Update Rate
Determine when the Accelerator Pedal 1 Low Idle Switch signal is not received on the Datalink

Monitor Operation:
DTC 558.9-SE709
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 260 msec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 297


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

230. 5742.9-SE12509: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Abnormal Update Rate
Determine when the J1939 proprietary EGTS (Exhaust Gas Temperature Sensor) Quad Temperature
message is not received on the Datalink

Monitor Operation:
DTC 5742.9-SE12509
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,510 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


J1939 proprietary EGTS Quad Temperature Message not received

Cummins Inc. Revision Date: March 30, 2017 298


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

231. 5742.9-SE12508: Aftertreatment Diesel Particulate Filter


Temperature Sensor Module - Abnormal Update Rate
Determine when the J1939 proprietary EGTS (Exhaust Gas Temperature Sensor) Quad Temperature
message is not received on the Datalink

Monitor Operation:
DTC 5742.9-SE12508
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,510 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


J1939 proprietary EGTS Quad Temperature Message not received

Cummins Inc. Revision Date: March 30, 2017 299


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

232. 3216.9-SE2487: Aftertreatment 1 Intake NOx Sensor - Abnormal


Update Rate
Determine when the AT1IG1 message is not received on the Datalink

Monitor Operation:
DTC 3216.9-SE2487
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 300


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

233. 3226.9-SE2488: Aftertreatment 1 Outlet NOx Sensor - Abnormal


Update Rate
Determine when the AT1OG1 message is not received on the Datalink

Monitor Operation:
DTC 3226.9-SE2488
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 301


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

234. 639.13-SE751: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Auxiliary Engine Shutdown Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE751
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 302


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

235. 639.9-SE716: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Auxiliary Engine Shutdown Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE716
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 303


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

236. 5605.31-SE6017: Cruise Control Pause Command - Condition Exists


Determine when a Cruise Control Resume Command is not received within time and vehicle speed
change requirements after cruise deactivation by a Cruise Control Pause Command.

Monitor Operation:
DTC 5605.31-SE6017
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,000 msec.
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Cruise control is inactive due to prior receipt of an active Cruise Control Pause Command signal in the
J1939 CCVS2 message.

Abort Conditions (any active):


Cruise control is not inactive due to prior receipt of an active Cruise Control Pause Command signal in
the J1939 CCVS2 message.

Malfunction Thresholds (all active):


Cruise control was paused more than 30 seconds due to a J1939 'Cruise Control Pause Command'
signal.
OR, vehicle speed dropped below cruise set speed by 14.913 mph during a J1939 'Cruise Control
Pause Command'.

Cummins Inc. Revision Date: March 30, 2017 304


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

237. 5603.9-SE5825: Cruise Control Disable Command - Abnormal


Update Rate
Determine when the J1939 CCVS2 message stops being received on the Datalink

Monitor Operation:
DTC 5603.9-SE5825
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)
A J1939 Component Identification (CI) message and subsequent CCVS2 message have been received
in the current key cycle from an authorized device.

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]
A J1939 Component Identification (CI) message and subsequent CCVS2 message have not been
received in the current key cycle from an authorized device.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 305


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

238. 5603.31-SE5995: Cruise Control Disable Command - Condition


Exists
Determine when cruise control is prohibited due to an active J1939 Cruise Control Disable Command
signal.

Monitor Operation:
DTC 5603.31-SE5995
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


A J1939 Component Identification (CI) message has been received in the current key cycle from an
authorized device.

Abort Conditions (any active):


A J1939 Component Identification (CI) message has not been received in the current key cycle from
an authorized device.

Malfunction Thresholds (all active):


Cruise Control Disable Command signal is disabling cruise control.

Cummins Inc. Revision Date: March 30, 2017 306


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

239. 5603.9-SE5996: Cruise Control Disable Command - Abnormal


Update Rate
Signal received for Cruise Control Disable Command is invalid.

Monitor Operation:
DTC 5603.9-SE5996
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


A J1939 Component Identification (CI) message has been received in the current key cycle from an
authorized device.

Abort Conditions (any active):


A J1939 Component Identification (CI) message has not been received in the current key cycle from
an authorized device.

Malfunction Thresholds (all active):


Cruise Control Disable Command signal is not valid.

Cummins Inc. Revision Date: March 30, 2017 307


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

240. 639.13-SE752: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Cruise Control Enable Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE752
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 308


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

241. 639.9-SE698: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Cruise Control Enable Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE698
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 309


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

242. 639.9-SE5158: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Cruise Control Pause Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE5158
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 310


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

243. 5603.9-SE5999: Cruise Control Disable Command - Abnormal


Update Rate
Signal received for Cruise Control Pause Command is invalid.

Monitor Operation:
DTC 5603.9-SE5999
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


A J1939 Component Identification (CI) message has been received in the current key cycle from an
authorized device.

Abort Conditions (any active):


A J1939 Component Identification (CI) message has not been received in the current key cycle from
an authorized device.

Malfunction Thresholds (all active):


Cruise Control Pause Command signal is not valid.

Cummins Inc. Revision Date: March 30, 2017 311


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

244. 639.13-SE753: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Cruise Control Resume Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE753
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 312


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

245. 639.9-SE702: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Cruise Control Resume Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE702
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 313


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

246. 5603.9-SE6000: Cruise Control Disable Command - Abnormal


Update Rate
Signal received for Cruise Control Resume Command is invalid.

Monitor Operation:
DTC 5603.9-SE6000
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


A J1939 Component Identification (CI) message has been received in the current key cycle from an
authorized device.

Abort Conditions (any active):


A J1939 Component Identification (CI) message has not been received in the current key cycle from
an authorized device.

Malfunction Thresholds (all active):


Cruise Control Resume Command signal is not valid.

Cummins Inc. Revision Date: March 30, 2017 314


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

247. 639.13-SE754: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Cruise Control Set Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE754
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 315


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

248. 639.9-SE701: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Cruise Control Set Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE701
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 316


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

249. 639.13-SE755: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Clutch Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE755
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 317


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

250. 639.9-SE700: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Clutch Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE700
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 318


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

251. 1761.13-SE8568: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


Sensor - Out of Calibration
Signal received for DEF (Diesel Exhaust Fluid) Tank Level does not meet requirements

Monitor Operation:
DTC 1761.13-SE8568
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 319


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

252. 1761.9-SE7665: Aftertreatment 1 Diesel Exhaust Fluid Tank Level -


Abnormal Update Rate
Determine when the DEF (Diesel Exhaust Fluid) Tank Level signal is not received on the Datalink

Monitor Operation:
DTC 1761.9-SE7665
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,100 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 320


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

253. 3031.13-SE8567: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature Sensor - Out of Calibration
Signal received for DEF (Diesel Exhaust Fluid) Tank Temperature does not meet requirements

Monitor Operation:
DTC 3031.13-SE8567
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 321


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

254. 3031.9-SE7666: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature - Abnormal Update Rate
Determine when the DEF (Diesel Exhaust Fluid) Tank Temperature signal is not received on the Datalink

Monitor Operation:
DTC 3031.9-SE7666
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,100 msec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Whenever any enable conditions is not met.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 322


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

255. 1081.9-SE5305: Engine Wait to Start Lamp - Abnormal Update Rate


Determine when the Direct Lamp Control Data 1 (DLCD1) message is not received on the Datalink from
Lamp Controller ECU

Monitor Operation:
DTC 1081.9-SE5305
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5.01 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on
event, a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event.
This is to allow reasonable time for datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 323


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

256. 639.13-SE7710: SAE J1939 Multiplexing Configuration Error - Out


of Calibration
J1939 Direct Lamp Control Data 1 (DLCD1) Engine Wait to Start Lamp (WTS) data received does not meet
requirements due to configuration error.

Monitor Operation:
DTC 639.13-SE7710
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on
event, a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event.
This is to allow reasonable time for datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


Received signal in "not available" state.

Cummins Inc. Revision Date: March 30, 2017 324


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

257. 1081.31-SE7712: Engine Wait to Start Lamp - Condition Exists


J1939 Direct Lamp Control Data 1 (DLCD1) Engine Wait to Start Lamp (WTS) status received does not
match commanded lamp status.

Monitor Operation:
DTC 1081.31-SE7712
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 counts
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Time since the last change in commanded J1939 Direct Lamp Control Data 1 (DLCD1) Engine Wait to
Start Lamp (WTS) status > 2 msec.

Abort Conditions (any active):


Time since the last change in commanded J1939 Direct Lamp Control Data 1 (DLCD1) Engine Wait to
Start Lamp (WTS) status <= 2 msec.

Malfunction Thresholds (all active):


Received lamp signal does not match the commanded lamp signal

Cummins Inc. Revision Date: March 30, 2017 325


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

258. 1081.19-SE7711: Engine Wait to Start Lamp - Received Network


Data in Error
J1939 Direct Lamp Control Data 1 (DLCD1) Engine Wait to Start Lamp (WTS) signal received does not
meet requirements due to network data error.

Monitor Operation:
DTC 1081.19-SE7711
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 326


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

259. 6806.31-SE12824: ECM 1 Data Link Interface Mismatch - Condition


Exists
The ECM is programmed with the wrong calibration with respect to SAE J1939 baud rate selection.

Monitor Operation:
DTC 6806.31-SE12824
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


EBC1 CAN message has not been received from the Anti-lock Braking System (A.B.S.) controller since
the last ECM reflash.

Cummins Inc. Revision Date: March 30, 2017 327


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

260. 563.31-SE7014: Anti-Lock Braking (ABS) Active - Condition Exists


J1939 EBC1(Electronic Brake Controller 1) message indicates ASR(Anti wheel Slip regulation) Engine
Control and/or ASR Brake Control has activated brake control.

Monitor Operation:
DTC 563.31-SE7014
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Stability Control device has supplied a component ID matching "BNDWS".

Abort Conditions (any active):


Stability Control device has not supplied a component ID matching "BNDWS".

Malfunction Thresholds (all active):


Cruise Control is active and the EBC1 message indicates brake control is active due to ASR (Anti-wheel
Slip Regulation) Engine Control or ASR Brake Control.

Cummins Inc. Revision Date: March 30, 2017 328


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

261. 563.9-SE7013: Anti-Lock Braking (ABS) Controller - Abnormal


Update Rate
Determine when the J1939 EBC1(Electronic Brake Controller 1) message stops being received on the
Datalink

Monitor Operation:
DTC 563.9-SE7013
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)
Stability Control device has supplied a component ID matching "BNDWS".
A J1939 EBC1 message has been received from the Stability Control device, since the last key on.

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]
Stability Control device has not supplied a component ID matching "BNDWS".

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 329


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

262. 639.13-SE757: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received from the Engine Shutdown Override Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE757
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 330


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

263. 639.9-SE704: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when Engine Shutdown Override Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE704
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 331


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

264. 96.13-SE7607: Fuel Level 1 - Out of Calibration


Signal received for Fuel Level 1 does not meet requirements.

Monitor Operation:
DTC 96.13-SE7607
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 332


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

265. 96.9-SE7606: Fuel Level 1 - Abnormal Update Rate


Determine when the Fuel Level 1 signal is not received on the Datalink

Monitor Operation:
DTC 96.9-SE7606
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 333


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

266. 38.13-SE8019: Fuel Level 2 - Out of Calibration


Signal received for Fuel Level 2 does not meet requirements.

Monitor Operation:
DTC 38.13-SE8019
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 334


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

267. 38.9-SE8020: Fuel Level 2 - Abnormal Update Rate


Determine when the Fuel Level 2 signal is not received on the Datalink

Monitor Operation:
DTC 38.9-SE8020
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 335


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

268. 639.13-SE758: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Idle Decrement Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE758
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 336


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

269. 639.9-SE694: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Idle Decrement Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE694
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 337


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

270. 639.13-SE759: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Idle Increment Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE759
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 338


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

271. 639.9-SE686: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Idle Increment Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE686
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 339


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

272. 91.19-SE1001: SAE J1939 Multiplexed Accelerator Pedal or Lever


Sensor System - Received Network Data in Error
Signal received for Accelerator Pedal Position indicates error.

Monitor Operation:
DTC 91.19-SE1001
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Signal indicates J1939 Error Code

Cummins Inc. Revision Date: March 30, 2017 340


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

273. 974.19-SE1002: SAE J1939 Multiplexing Remote Accelerator Pedal


or Lever Sensor System - Received Network Data in Error
Signal received for Remote Accelerator Pedal Position indicates error.

Monitor Operation:
DTC 974.19-SE1002
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Signal indicates J1939 Error Code

Cummins Inc. Revision Date: March 30, 2017 341


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

274. 191.19-SE5109: Transmission Output Shaft Speed - Received


Network Data in Error
Signal received for Transmission Output Shaft Speed indicates error and no alternative valid signal is
available.

Monitor Operation:
DTC 191.19-SE5109
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 40 msec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Output Shaft Speed signal indicates error and there are no alternative sources with a valid signal.

Cummins Inc. Revision Date: March 30, 2017 342


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

275. 191.9-SE5110: Transmission Output Shaft Speed - Abnormal


Update Rate
Determine when no "valid signal" is received on the Datalink for the Transmission Output Shaft Speed
signal.

Monitor Operation:
DTC 191.9-SE5110
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,510 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 343


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

276. 639.13-SE760: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Parking Brake Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE760
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 344


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

277. 639.9-SE697: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Parking Brake Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE697
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 345


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

278. 639.9-SE710: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Engine PTO Governor Accelerate Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE710
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 346


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

279. 639.9-SE711: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Engine PTO Governor Coast/Decelerate Switch signal is not received on the
Datalink

Monitor Operation:
DTC 639.9-SE711
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 347


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

280. 639.13-SE763: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Remote PTO Preprogrammed Speed Control Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE763
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 348


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

281. 639.9-SE706: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Remote PTO Preprogrammed Speed Control Switch signal is not received on the
Datalink

Monitor Operation:
DTC 639.9-SE706
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 349


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

282. 639.13-SE764: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received from the PTO Resume Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE764
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 350


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

283. 639.9-SE707: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when PTO Resume Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE707
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 351


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

284. 639.13-SE765: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for PTO Set Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE765
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 352


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

285. 639.9-SE708: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the PTO Set Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE708
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 353


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

286. 639.13-SE766: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for PTO Enable Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE766
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 354


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

287. 639.9-SE705: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the PTO Enable Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE705
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 355


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

288. 639.13-SE2108: SAE J1939 Multiplexing Configuration Error - Out


of Calibration
Signal received for Particulate Trap Regeneration Force Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE2108
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 356


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

289. 639.9-SE2109: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Particulate Trap Regeneration Force Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE2109
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 357


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

290. 639.13-SE2110: SAE J1939 Multiplexing Configuration Error - Out


of Calibration
Signal received for Particulate Trap Regeneration Inhibit Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE2110
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 358


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

291. 639.9-SE2111: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Particulate Trap Regeneration Inhibit Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE2111
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 359


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

292. 639.13-SE767: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Two Speed Axle Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE767
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 360


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

293. 639.9-SE695: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Two Speed Axle Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE695
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 361


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

294. 639.13-SE769: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Remote Accelerator Pedal Position does not meet requirements

Monitor Operation:
DTC 639.13-SE769
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 362


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

295. 639.13-SE768: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Remote Accelerator Pedal Enable Switch does not meet requirements

Monitor Operation:
DTC 639.13-SE768
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 363


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

296. 639.9-SE715: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Remote Accelerator Pedal Enable Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE715
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 364


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

297. 639.9-SE713: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Remote Accelerator Pedal Position signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE713
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 260 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 365


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

298. 639.13-SE5188: SAE J1939 Multiplexing Configuration Error - Out


of Calibration
Signal received for Requested Percent Fan Speed 2 does not meet requirements

Monitor Operation:
DTC 639.13-SE5188
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 366


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

299. 639.9-SE5187: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Requested Percent Fan Speed 2 signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE5187
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 367


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

300. 639.13-SE770: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Requested Percent Fan Speed does not meet requirements

Monitor Operation:
DTC 639.13-SE770
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 368


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

301. 639.9-SE696: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Requested Percent Fan Speed signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE696
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 369


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

302. 639.13-SE771: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Engine Retarder Selection does not meet requirements

Monitor Operation:
DTC 639.13-SE771
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 370


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

303. 639.9-SE719: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Engine Retarder Selection signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE719
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 371


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

304. 639.13-SE773: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Service Brake does not meet requirements

Monitor Operation:
DTC 639.13-SE773
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 372


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

305. 639.9-SE699: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Service Brake signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE699
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 373


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

306. 1623.9-SE5307: Tachograph Output Shaft Speed - Abnormal


Update Rate
Determine when the J1939 TC01 message is not received on the Datalink

Monitor Operation:
DTC 1623.9-SE5307
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 260 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 374


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

307. 639.13-SE746: SAE J1939 Multiplexing Configuration Error - Out of


Calibration
Signal received for Engine Test Mode Switch does not meet requirements.

Monitor Operation:
DTC 639.13-SE746
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 375


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

308. 639.9-SE703: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Engine Test Mode Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE703
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 376


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

309. 639.9-SE717: SAE J1939 Multiplexing PGN Timeout Error -


Abnormal Update Rate
Determine when the Engine Derate Switch signal is not received on the Datalink

Monitor Operation:
DTC 639.9-SE717
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 510 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 377


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

310. 3364.13-SE8569: Aftertreatment Diesel Exhaust Fluid Quality - Out


of Calibration
J1939 Urea Quality Sensor fluid temperature 2 signal received does not meet requirements.

Monitor Operation:
DTC 3364.13-SE8569
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on
event, a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event.
This is to allow reasonable time for datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


Received signal without valid data.

Cummins Inc. Revision Date: March 30, 2017 378


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

311. 3364.9-SE6447: Aftertreatment Diesel Exhaust Fluid Quality -


Abnormal Update Rate
Determine when the J1939 DEF quality message is not received on the Datalink

Monitor Operation:
DTC 3364.9-SE6447
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on
event, a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event.
This is to allow reasonable time for datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 379


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

312. 1818.31-SE4354: Roll Over Protection Brake Control Active -


Condition Exists
J1939 VDC1 message indicates that one or more of ROP Engine Control active, ROP Brake Control active,
YC Engine Control active, or YC Brake Control active are "active".

Monitor Operation:
DTC 1818.31-SE4354
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Stability Control device has supplied a component ID matching "BNDWS".

Abort Conditions (any active):


Stability Control device has not supplied a component ID matching "BNDWS".

Malfunction Thresholds (all active):


Cruise control is active AND VDC1 message indicates brake or engine control is active due to vehicle
yaw or roll-over protection.

Cummins Inc. Revision Date: March 30, 2017 380


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

313. 563.9-SE3606: Anti-Lock Braking (ABS) Controller - Abnormal


Update Rate
Determine when the J1939 Vehicle Dynamic Stability Control 1 (VDC1) message is not received over the
Datalink

Monitor Operation:
DTC 563.9-SE3606
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,010 msec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)
Stability Control device has supplied a component ID matching "BNDWS".
A J1939 VDC1 message has been received from the Stability Control device, since the last key on.

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]
Stability Control device has not supplied a component ID matching "BNDWS".
A J1939 VDC1 message has not been received from the Stability Control device, since the last key on.

Malfunction Thresholds (all active):


Message not received

Cummins Inc. Revision Date: March 30, 2017 381


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

314. 641.9-SE8054: VGT Actuator Driver Circuit - Abnormal Update Rate


Determine when the VGT (Variable Geometry Turbocharger) Status signal is not received over the
datalink.

Monitor Operation:
DTC 641.9-SE8054
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,010 msec.
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT [ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on
event, a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event.
This is to allow reasonable time for datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


VGT Status Message not received

Cummins Inc. Revision Date: March 30, 2017 382


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

315. 84.19-SE5111: Wheel-Based Vehicle Speed - Received Network


Data in Error
Signal received for Transmission Output Shaft Speed, used to determine vehicle speed, indicates error
and no alternative valid signal is available.

Monitor Operation:
DTC 84.19-SE5111
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 40 msec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Output Shaft Speed signal indicates error and there are no alternative sources with a valid signal.

Cummins Inc. Revision Date: March 30, 2017 383


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

316. 84.9-SE5112: Wheel-Based Vehicle Speed - Abnormal Update Rate


Signal used to determine vehicle speed is not received on the Datalink.

Monitor Operation:
DTC 84.9-SE5112
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


NOT[Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)]

Malfunction Thresholds (all active):


Message not received for 1,510 msec
Message not received for 260 msec

Cummins Inc. Revision Date: March 30, 2017 384


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

317. 1378.31-SE1904: Engine Oil Change Interval - Condition Exists


Engine Oil Change Interval - Condition Exists

Monitor Operation:
DTC 1378.31-SE1904
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Oil Change Monitor Percent Interval Used > 90 %

Cummins Inc. Revision Date: March 30, 2017 385


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

318. 3597.12-SE421: Injector Power Supply - Bad Intelligent Device or


Component
Detect low boost voltage error when boost voltage is below a calibrated voltage threshold

Monitor Operation:
DTC 3597.12-SE421
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Measured Boost Voltage < 45 V

Cummins Inc. Revision Date: March 30, 2017 386


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

319. 102.16-SE7293: Intake Manifold 1 Pressure - Data Valid But Above


Normal Operating Range - Moderately Severe Level
Charge Flow higher than normal.

Monitor Operation:
DTC 102.16-SE7293
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Fresh Air Flow Command < 9 kg/min
Fresh Air Flow Command > 25 kg/min
EGR Valve Effective Flow Area < 0.8 cm2
EGR Valve Effective Flow Area > 3.1 cm2
EGR Delta Pressure sensor autozero check is not complete
Total Fueling > 200 mg/stroke
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (EGR Flow - Estimated EGR Flow) over a 30 second period is ever > 2 kg/min Diagnostic
Tolerance = 0 kg/min (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 387


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

320. 102.18-SE7294: Intake Manifold 1 Pressure - Data Valid But Below


Normal Operating Range - Moderately Severe Level
Charge Flow lower than normal.

Monitor Operation:
DTC 102.18-SE7294
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Charge Flow Command < 12 kg/min
Charge Flow Command > 25 kg/min
EGR Valve Effective Flow Area < 0.5 cm2
EGR Valve Effective Flow Area > 2 cm2
EGR Delta Pressure sensor autozero check is not complete
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (Estimated Charge Flow - Charge Flow) over a 30 second period is ever > 2.5 kg/min
Diagnostic Tolerance = 0 kg/min (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 388


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

321. 102.10-SE12124: Intake Manifold 1 Pressure - Abnormal Rate of


Change
Charge Flow System Response slower than normal.

Monitor Operation:
DTC 102.10-SE12124
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 40 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Charge Flow Command < 10 kg/min
Charge Flow Command > 25 kg/min
EGR Valve Effective Flow Area < 1.35 cm2
EGR Valve Effective Flow Area > 3 cm2
EGR Delta Pressure sensor autozero check is not complete
|Rate of change of (Engine Speed * Commanded Fueling)| over 0.1 sec. < 1,000 (rpm * mg) / (stroke
* sec)
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 °C) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


Average of (Estimated Mass Air Flow - Mass Air Flow) over a 40 second period is ever > 1.938 kg/min
Diagnostic Tolerance = 0 kg/min (Please refer to the CUSUM Supplement in Section C for further
details.)

Cummins Inc. Revision Date: March 30, 2017 389


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

322. 1322.31-SE2350: Engine Misfire for Multiple Cylinders - Condition


Exists
A multiple cylinder misfire fault is detected whenever more than one cylinder is failing to produce
expected torque in response to a calibrated increase in its commanded fueling.

Monitor Operation:
DTC 1322.31-SE2350
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
Engine is in WARM State.
Engine is at IDLE State.
OBD arbitrator allows Misfire Monitor to run.
Engine is operating in any of the following modes:
Engine is operating in Aftertreatment base mode (not in DENOX, DESOOT, DESOX, DESORB).

Pause Conditions (any active):


188.16-SE3775, 188.18-SE3781
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
157.3-SE525, 157.4-SE526
1349.3-SE6690, 1349.4-SE6691
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915

Cummins Inc. Revision Date: March 30, 2017 390


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is not in WARM State.


Engine is not at IDLE State.
OBD arbitrator doesn't allow Misfire Monitor to run.
Engine is not operating in all of the following modes:
Aftertreatment Base mode (not in DENOX, DESOOT, DESOX, DESORB).

Malfunction Thresholds (all active):


Total number of misfiring cylinders > 1 counts

Cummins Inc. Revision Date: March 30, 2017 391


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

323. 91.2-SE3200: Accelerator Pedal or Lever Position Sensor 1 - Data


Erratic, Intermittent, or Incorrect
Muxed Accelerator Pedal Position Rationality Diagnostic

Monitor Operation:
DTC 91.2-SE3200
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Accelerator Pedal Position is received through the Datalink

Pause Conditions (any active):


558.19-SE5333, 558.9-SE709, 91.13-SE748, 91.13-SE750, 91.19-SE1001, 91.9-SE712

Malfunction Thresholds (all active):


(On Idle Switch = On Idle and (Muxed Accelerator Pedal Position > 12%)) OR (On Idle Switch = Off Idle
and (Muxed Accelerator Pedal Position <= 12%))

Cummins Inc. Revision Date: March 30, 2017 392


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

324. 3216.2-SE5369: Aftertreatment 1 Intake NOx - Data Erratic,


Intermittent, or Incorrect
Engine Out NOx sensor reading is stuck in range.

Monitor Operation:
DTC 3216.2-SE5369
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 22 seconds
MIL Activation Criteria 2 trips

Entry Conditions (all active):


|Estimated Engine Out NOx Concentration - filtered (tau = 3.8 sec) estimated Engine Out NOx
Concentration| > 70 ppm.

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
Aftertreatment Inlet NOx sensor reading is not valid. (See RefCond69.9.)
|Estimated Engine Out NOx Concentration - filtered (tau = 3.8 sec) estimated Engine Out NOx
Concentration| < 60 ppm. Where: to exit this Pause Condition the | Estimated Engine Out NOx
Concentration - filtered (tau = 3.8 sec) estimated Engine Out NOx Concentration | > 70 ppm
|Engine speed - filtered (tau = 3.8 sec) Engine Speed| < 100 RPM
Engine is not in run state

Malfunction Thresholds (all active):


Change of Engine Out NOx Sensor value over the monitoring period < 70 ppm

Cummins Inc. Revision Date: March 30, 2017 393


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

325. 3216.20-SE5365: Aftertreatment 1 Intake NOx Sensor - Data Not


Rational - Drifted High
Engine out NOx sensor reading is in-range high during motoring condition.

Monitor Operation:
DTC 3216.20-SE5365
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 5 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494
Engine is not in motoring condition
Duration for having permission by OBD arbitrator < 5 sec
Aftertreatment Inlet NOx sensor reading is not valid. (See RefCond69.9.)
Engine is in mobile DeSoot Mode.
Engine is in Engine Protection State.
Engine is in Hydrocarbon Desorption Mode.
Engine is in stationary DeSoot Mode.

Malfunction Thresholds (all active):


Average of (Engine Out NOx - 0 ppm) over a 5 second period is ever ≥ 70 ppm Diagnostic Tolerance =
0 ppm (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 394


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

326. 3216.21-SE5366: Aftertreatment 1 Intake NOx Sensor - Data Not


Rational - Drifted Low
Engine out NOx sensor reading is in-range low during motoring condition.

Monitor Operation:
DTC 3216.21-SE5366
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 5 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494
Engine is not in motoring condition
Duration for having permission by OBD arbitrator < 5 sec
Aftertreatment Inlet NOx sensor reading is not valid. (See RefCond69.9.)
Engine is in mobile DeSoot Mode.
Engine is in Engine Protection State.
Engine is in Hydrocarbon Desorption Mode.
Engine is in stationary DeSoot Mode.

Malfunction Thresholds (all active):


Average of (0 ppm - Engine Out NOx) over a 5 second period is ever ≥ 50 ppm Diagnostic Tolerance =
0 ppm (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 395


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

327. 3216.10-SE5569: Aftertreatment 1 Intake NOx Sensor - Abnormal


Rate of Change
Engine out NOx sensor signal is not valid for a persistent period of time.

Monitor Operation:
DTC 3216.10-SE5569
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 150 sec
MIL Activation Criteria 2 trips

Abort Conditions (any active):


3216.9-SE2487
3222.5-SE5151
3216.4-SE5153
3218.2-SE5152
NOx Sensor internal operating temperature < 800 degC
Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached. (See RefCond9.6.)
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 100 seconds

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3242.2-
SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 3251.10-
SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-SE2882, 3610.4-
SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-
SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729, 4765.3-SE6735, 4765.4-
SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724, 5742.12-SE6725,
5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
NOT [ %O2 reading of Exhaust Air virtual sensor is valid (See RefCond28.9.) ]
The rate of change of estimated engine out O2 ≥ 7 %/s
The rate of change of estimated exhaust pressure ≥ 5 kPa(absolute)/s

Malfunction Thresholds (all active):


NOx sensor reading is not valid due to internal control loops within the sensor being unstable.. (See
RefCond8.5.)

Cummins Inc. Revision Date: March 30, 2017 396


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

328. 3226.4-SE5990: Aftertreatment 1 Outlet NOx Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The NOx sensor circuitry has detected a failure affecting the aftertreatment outlet NOx sensor heater
circuit.

Monitor Operation:
DTC 3226.4-SE5990
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Processing of fail messages from the NOx out sensor enabled 160 seconds after Exhaust gas
temperature is above a threshold representing the point at which there is no longer a concern of
condensation on the NOx sensor element. (See RefCond19.8.)

Abort Conditions (any active):


3226.9-SE2488

Pause Conditions (any active):


Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)

Malfunction Thresholds (all active):


[Open H-] The resistance between the sensors heater connection to Ground and a 3rd heater
electrode > 1,000,000 ohms for 10 seconds.
or
[Open H+] The resistance between the sensors heater supply and a 3rd heater electrode > 1,000,000
ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or

Cummins Inc. Revision Date: March 30, 2017 397


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[H+/Tmp] The voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms for 40 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[Open Tmp] The resistance between the sensors 3rd electrode within its internal heater is >
1,000,000 ohms for 10 seconds.
or
[M1/M2] 5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode for 40 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 V for 10 seconds.
or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 0 ohms for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 398


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 399


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

329. 5031.10-SE5051: Aftertreatment 1 Outlet NOx Sensor Heater -


Abnormal Rate of Change
Aftertreatment outlet NOx sensor heater malfunction.

Monitor Operation:
DTC 5031.10-SE5051
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
Exhaust gas velocity < 60 m/sec
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.)
SCR outlet temperature < 800 °C
Nox sensor battery supply voltage is within the desired range of [10.8, 16.5] V for more than 0.2
seconds.
Key switch is turned ON
NOx Sensor status is not equal to data not available and NOx Sensor status is not equal to no value.

Abort Conditions (any active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
Exhaust gas velocity ≥ 60 m/sec
SCR outlet temperature ≥ 800 °C
Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)
Nox sensor battery supply voltage is outside the desired range of [10.8, 16.5] V.
Key switch is turned OFF
NOx Sensor status is data not available or NOx Sensor status has no value.

Malfunction Thresholds (all active):


Time for NOx sensor heater to reach working temperature of 800 Deg C after enable conditions are
satisfied ≥ 120 sec

Cummins Inc. Revision Date: March 30, 2017 400


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

330. 3226.20-SE5976: Aftertreatment 1 Outlet NOx Sensor - Data Not


Rational - Drifted High
Aftertreatment outlet NOx sensor in-range but reading inappropriately high.

Monitor Operation:
DTC 3226.20-SE5976
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
Engine is in motoring condition
NOx sensor reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond17.3.)
Engine is operating in aftertreatment base mode.
Exhaust Flow ≥ 75 g/sec
Commanded DEF injection rate < 0.1 ml/sec
The OBD Arbitrator allows the Tail Pipe NOx Sensor gain diagnostics to run.
The OBD Arbitrator allows the diagnostic to run.
All the other enable conditions has to be true for 6 seconds.

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878

Cummins Inc. Revision Date: March 30, 2017 401


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927

Pause Conditions (any active):


Estimated SCR catalyst bed temperature rate of change is > RefTable19.4. Pause condition is exited if
the estimated SCR catalyst bed temperature has decreased by at least 20 Deg C from its maximum
temperature value for a minimum cumulative time of 10seconds. OR Pause condition is exited if the
estimated SCR catalyst bed temperature rate of change is < RefTable21.4 for a minimum cumulative
time of 180seconds.

Malfunction Thresholds (all active):


The EWMA filtered value of average NOx sensor offset measurement at the decision point > 50ppm
where a decision point is said to occur at the end of a motoring event during which the diagnostic was
continuously enabled for at least 2seconds

Cummins Inc. Revision Date: March 30, 2017 402


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

331. 3226.21-SE5978: Aftertreatment 1 Outlet NOx Sensor - Data Not


Rational - Drifted Low
Aftertreatment outlet NOx sensor in-range but reading inappropriately low.

Monitor Operation:
DTC 3226.21-SE5978
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
Engine is in motoring condition
NOx sensor reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond17.3.)
Engine is operating in aftertreatment base mode.
Exhaust Flow ≥ 75 g/sec
Commanded DEF injection rate < 0.1 ml/sec
The OBD Arbitrator allows the Tail Pipe NOx Sensor gain diagnostics to run.
The OBD Arbitrator allows the diagnostic to run.
All the other enable conditions has to be true for 6 seconds.

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878

Cummins Inc. Revision Date: March 30, 2017 403


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927
3361.4-SE7290, 3362.31-SE6980, 4334.18-SE7005, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095,
4375.4-SE6094, 5394.5-SE5102, 5394.7-SE7927

Pause Conditions (any active):


Estimated SCR catalyst bed temperature rate of change is > RefTable20.4. Pause condition is exited if
the estimated SCR catalyst bed temperature has decreased by at least 20 Deg C from its maximum
temperature value for a minimum cumulative time of 10seconds. OR Pause condition is exited if the
estimated SCR catalyst bed temperature rate of change is < RefTable22.4 for a minimum cumulative
time of 180seconds.

Malfunction Thresholds (all active):


The EWMA filtered value of average NOx sensor offset measurement at the decision point < -30ppm
where a decision point is said to occur at the end of a motoring event during which the diagnostic was
continuously enabled for at least 2seconds

Cummins Inc. Revision Date: March 30, 2017 404


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

332. 3226.4-SE11104: Aftertreatment 1 Outlet NOx Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The NOx sensor circuitry has detected a failure within the aftertreatment outlet NOx sensor's internal
O2 circuitry that causes the O2 value to be suspect.

Monitor Operation:
DTC 3226.4-SE11104
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Processing of fail messages from the NOx out sensor enabled 160 seconds after dewpoint reached.
Dewpoint is defined as: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. (See RefCond19.8.)

Abort Conditions (any active):


3226.9-SE2488

Pause Conditions (any active):


Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)

Malfunction Thresholds (all active):


[Open P+] The resistance between the electrode on the top of the sensor (directly exposed to exhaust
gas) and ground > 1,000,000 ohms for 10 seconds.
or
[Open Ref] The resistance between the sensors air reference electrode and ground > 1,000,000 ohms
for 10 seconds.
or
[Open M1] The resistance between the sensors pumping electrode in the 2nd chamber and ground >
1,000,000 ohms for 10 seconds.
or
[Open P-] The resistance between the sensors pumping electrode in 1st pumping chamber and
ground > 1,000,000 ohms for 10 seconds.
or
[Ref/M2] (The resistance between the sensors air reference electrode and the sensors measuring
electrode in the 2nd chamber is < 0.5 ohms AND the voltage between the pumping electrode in the
2nd chamber and reference is within 20mV of a 420mV setpoint AND the voltage between the
measuring electrode in the 2nd chamber and the reference < 15mV) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 405


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P-/M2] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the measuring electrode in the 2nd chamber and
reference) for 40 seconds.
or
[P+/M2] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
measuring electrode within the 2nd chamber is < 0.5 ohms AND the voltage between the measuring
electrode in the 2nd chamber and reference < 120 mV) for 40 seconds.
or
[P-/M1] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the pumping electrode in the 2nd chamber and
reference) for 40 seconds.
or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 1,000,000 ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[H+/Tmp] (the voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms) for 40 seconds.
or
[Ref/H+] The resistance between the air reference electrode and the sensors internal heater supply <
0.5 ohms for 10 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 for 10 seconds.
or
[Ref/H-] The resistance between the air reference electrode and ground < 0.5 ohms for 10 seconds.
or
[Ref/M1] The resistance between the sensors air reference electrode and the sensors pumping
electrode in the 2nd chamber is < 0.5 ohms for 10 seconds.
or
[M1/H+] (The resistance between the pumping electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms AND the voltage between the electrode in the 1st chamber
and the air reference electrode < 25.6 mV) for 40 seconds.
or
[P+/P-] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 1st chamber is < 0.5 ohms AND | the current entering the pumping
electrode in the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the
2nd chamber and the reference < 100 mV ) for 40 seconds.
or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.

Cummins Inc. Revision Date: March 30, 2017 406


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P-/H+] The resistance between the pumping electrode in the 1st chamber and the sensors internal
heater supply is < 0.5 ohms for 10 seconds.
or
[M1/H-] The resistance between the pumping electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M2/H-] The resistance between the measuring electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P-/H-] The resistance between the pumping electrode in the 1st chamber and ground is < 0.5 ohms
for 10 seconds.
or
[M2/H+] The resistance between the measuring electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms for 10 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[P+/M1] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 2nd chamber is < 0.5 ohms AND the binary voltage between the
sensors top electrode and reference < 200 mV AND ((| the current entering the pumping electrode in
the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the 2nd chamber
and the reference < 100 mV) OR (binary voltage between the sensors top electrode and reference =
the voltage between the pumping electrode in the 2nd chamber and reference)) for 40 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or
[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 407


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P+/H-] The resistance between the electrode in on the top of the sensor (exposed to the exhaust gas)
and ground is < 0.5 ohms for 10 seconds.
or
[Ref/P-] (The resistance between the air reference electrode and pumping electrode in the 1st
chamber < 0.5 ohms AND the voltage between the electrode in the 1st chamber and the air reference
electrode < 25.6 mV) for 40 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[M1/M2] (5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 408


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

333. 3226.10-SE5989: Aftertreatment 1 Outlet NOx Sensor - Abnormal


Rate of Change
Aftertreatment outlet NOx sensor status is not valid for a persistent period of time.

Monitor Operation:
DTC 3226.10-SE5989
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
Engine is not in motoring condition AND Rate of active/intrusive injection of HC's in exhaust < 0.2
g/sec for 30 seconds.
Internal NOx sensor temperature > 800 °C
The changing range of exhaust O2 concentration within a 12 second moving window <= 9.96 %
The changing range of exhaust O2 concentration within a 6 second moving window <= 5.43 %
(Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.) AND sensor supply power
>= 6 V) For 150 seconds
%O2 reading of Exhaust Air virtual sensor is valid (See RefCond28.9.)

Abort Conditions (any active):


3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
NOx Out sensor temperature < 800 degC
The changing range of exhaust O2 concentration within a 12 second moving window > 9.96 %
The changing range of exhaust O2 concentration within a 6 second moving window > 5.43 %
Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.) OR sensor supply power < 6 V
NOT[%O2 reading of Exhaust Air virtual sensor is valid (See RefCond28.9.)]

Pause Conditions (any active):


Engine is in motoring condition

Cummins Inc. Revision Date: March 30, 2017 409


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Rate of active/intrusive injection of HC's in exhaust ≥ 0.2 g/sec

Malfunction Thresholds (all active):


Percent of time > 50 % when NOx sensor reading is valid since the internal control loops within the
sensor have stabilized. (See RefCond17.3.) is invalid

Cummins Inc. Revision Date: March 30, 2017 410


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

334. 3228.2-SE5988: Aftertreatment 1 Outlet NOx Sensor Power Supply


- Data Erratic, Intermittent, or Incorrect
The aftertreatment outlet NOx sensor circuitry has detected that its battery supply voltage is outside the
desired range.

Monitor Operation:
DTC 3228.2-SE5988
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Processing of fail messages from the NOx out sensor enabled 160 seconds after dewpoint reached.
Dewpoint is defined as: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. (See RefCond19.8.)

Abort Conditions (any active):


3226.9-SE2488

Pause Conditions (any active):


Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)

Malfunction Thresholds (all active):


NOx sensor supply voltage > 16.5 V for 10 seconds.
OR
NOx sensor supply voltage < 10.8 V for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 411


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

335. 3228.2-SE6021: Aftertreatment 1 Outlet NOx Sensor Power Supply


- Data Erratic, Intermittent, or Incorrect
The system out NOx sensor circuitry has detected an intermittent power supply voltage drop that results
in a reset internal to the system out NOx sensor.

Monitor Operation:
DTC 3228.2-SE6021
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.) for less than 5 seconds

Abort Conditions (any active):


Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)

Malfunction Thresholds (all active):


The number of filtered sensor reset events (sensor supply power < 6 V) is greater than 12 counts,
within a diagnostic time window (300 sec). Sensor reset events are "filtered" by ignoring consecutive
reset events occuring within (20 sec).

Cummins Inc. Revision Date: March 30, 2017 412


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

336. 3226.4-SE5987: Aftertreatment 1 Outlet NOx Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The NOx sensor circuitry has detected a failure within the aftertreatment outlet NOx sensor's internal
circuitry that causes the sensed NOx value to be suspect.

Monitor Operation:
DTC 3226.4-SE5987
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 seconds
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Processing of fail messages from the NOx out sensor enabled 160 seconds after dewpoint reached.
Dewpoint is defined as: Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. (See RefCond19.8.)

Abort Conditions (any active):


3226.9-SE2488

Pause Conditions (any active):


Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)

Malfunction Thresholds (all active):


[Open P+] The resistance between the electrode on the top of the sensor (directly exposed to exhaust
gas) and ground > 1,000,000 ohms for 10 seconds.
or
[Open Ref] The resistance between the sensors air reference electrode and ground > 1,000,000 ohms
for 10 seconds.
or
[Open M1] The resistance between the sensors pumping electrode in the 2nd chamber and ground >
1,000,000 ohms for 10 seconds.
or
[Open P-] The resistance between the sensors pumping electrode in 1st pumping chamber and
ground > 1,000,000 ohms for 10 seconds.
or
[Ref/M2] (The resistance between the sensors air reference electrode and the sensors measuring
electrode in the 2nd chamber is < 0.5 ohms AND the voltage between the pumping electrode in the
2nd chamber and reference is within 20mV of a 420mV setpoint AND the voltage between the
measuring electrode in the 2nd chamber and the reference < 15mV) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 413


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P-/M2] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the measuring electrode in the 2nd chamber and
reference) for 40 seconds.
or
[P+/M2] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
measuring electrode within the 2nd chamber is < 0.5 ohms AND the voltage between the measuring
electrode in the 2nd chamber and reference < 120 mV) for 40 seconds.
or
[P-/M1] (The binary voltage between the electrode on the top of the sensor (exposed to the exhaust
gas) and the air reference electrode > 900 mV AND the voltage across the electrode in the 1st
chamber and reference = the voltage across the pumping electrode in the 2nd chamber and
reference) for 40 seconds.
or
[Open M2] The resistance between the sensors measuring electrode in the 2nd chamber and ground
> 1,000,000 ohms for 10 seconds.
or
[H-/Tmp] The voltage between the 3rd electrode within the sensors internal heater and ground < 0.5
V for 10 seconds.
or
[H+/Tmp] (the voltage between the 3rd electrode within the internal heater and ground < 2.19 V AND
the sensors internal heater resistance < 20.97 Ohms) for 40 seconds.
or
[Ref/H+] The resistance between the air reference electrode and the sensors internal heater supply <
0.5 ohms for 10 seconds.
or
[Vbatt/Tmp] The voltage at the 3rd electrode within the sensors internal heater > 8 V for 10 seconds.
or
[Ref/H-] The resistance between the air reference electrode and ground < 0.5 ohms for 10 seconds.
or
[Ref/M1] The resistance between the sensors air reference electrode and the sensors pumping
electrode in the 2nd chamber is < 0.5 ohms for 10 seconds.
or
[M1/H+] (The resistance between the pumping electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms AND the voltage between the electrode in the 1st chamber
and the air reference electrode < 25.6 mV) for 40 seconds.
or
[P+/P-] (The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 1st chamber is < 0.5 ohms AND | the current entering the pumping
electrode in the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the
2nd chamber and the reference < 100 mV ) for 40 seconds.
or
[Ref/Tmp] (The resistance between the sensors air reference electrode and the sensors 3rd electrode
within its internal heater is < 0.5 ohms AND the voltage between reference line and ground < 1 V) for
40 seconds.

Cummins Inc. Revision Date: March 30, 2017 414


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P-/H+] The resistance between the pumping electrode in the 1st chamber and the sensors internal
heater supply is < 0.5 ohms for 10 seconds.
or
[M1/H-] The resistance between the pumping electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P+/Tmp] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M2/H-] The resistance between the measuring electrode in the 2nd chamber and ground < 0.5 ohms
for 10 seconds.
or
[P-/H-] The resistance between the pumping electrode in the 1st chamber and ground is < 0.5 ohms
for 10 seconds.
or
[M2/H+] The resistance between the measuring electrode in the 2nd chamber and the supply voltage
to the sensors internal heater < 0.5 ohms for 10 seconds.
or
[H+/H-] The resistance between the sensors internal heater supply voltage line and sensor ground is <
0.5 ohms for 10 seconds.
or
[M2/Tmp] The resistance between the sensors measuring electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[Vbatt/M1] The resistance between supply voltage and the sensors pumping electrode in the 2nd
pumping chamber is < 0.5 ohms for 10 seconds.
or
[P+/M1] The resistance between the sensors top electrode (directly exposed to exhaust gas) and the
pumping electrode within the 2nd chamber is < 0.5 ohms AND the binary voltage between the
sensors top electrode and reference < 200 mV AND ((| the current entering the pumping electrode in
the 2nd chamber | > -19.5 uA AND the voltage between the pumping electrode in the 2nd chamber
and the reference < 100 mV) OR (binary voltage between the sensors top electrode and reference =
the voltage between the pumping electrode in the 2nd chamber and reference)) for 40 seconds.
or
[Vbatt/Ref] The resistance between supply voltage and the sensors air reference electrode is < 0.5
ohms for 10 seconds.
or
[Vbatt/M2] The resistance between supply voltage and the sensors measuring electrode in 2nd
chamber is < 0.5 ohms for 10 seconds.
or
[P-/Tmp] The resistance between the sensors pumping electrode in the 1st pumping chamber and the
3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.
or
[M1/Tmp] The resistance between the sensors pumping electrode in the 2nd pumping chamber and
the 3rd electrode within the sensors internal heater is < 0.5 ohms for 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 415


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

or
[P+/H-] The resistance between the electrode in on the top of the sensor (exposed to the exhaust gas)
and ground is < 0.5 ohms for 10 seconds.
or
[Ref/P-] (The resistance between the air reference electrode and pumping electrode in the 1st
chamber < 0.5 ohms AND the voltage between the electrode in the 1st chamber and the air reference
electrode < 25.6 mV) for 40 seconds.
or
[Vbatt/P-] The resistance between supply voltage and the sensors pumping electrode in the 1st
pumping chamber is < 0.5 ohms for 10 seconds.
or
[Vbatt/P+] The resistance between supply voltage and the sensors top electrode (directly exposed to
exhaust gas) is < 0.5 ohms for 10 seconds.
or
[Vbatt/H+] The resistance between supply voltage and the sensors heater supply is < 0.5 ohms for 10
seconds.
or
[M1/M2] (5 mV < the voltage between the measuring electrode in the 2nd chamber with respect to
the air reference electrode < 500 mV AND the voltage between the pumping electrode in the 2nd
chamber and the air reference electrode = the voltage between the measuring electrode in the 2nd
chamber with respect to the air reference electrode) for 40 seconds.

Cummins Inc. Revision Date: March 30, 2017 416


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

337. 3226.11-SE11496: Aftertreatment 1 Outlet NOx Sensor - Root


Cause Not Known
Detect when the SONOx Sensor is removed from the exhaust pipe.

Monitor Operation:
DTC 3226.11-SE11496
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
3226.10-SE5989
5031.10-SE5982
Ambient air pressure ≥ 75 kPa(absolute)
Ambient air temperature ≥ -6.7 °C
NOT[Aftertreatment Outlet NOx sensor reading is not valid due to internal control loops within the
sensor being unstable, or active faults detected by the sensor, or the sensor's battery supply voltage
is outside the desired range or dewpoint temperature not met. (See RefCond167.8.)]
Virtual SCR Inlet O2% < 17 %
Exhaust flow > 100 g/sec
Engine is not in motoring condition
Enable conditions met for ≥ 15 sec

Abort Conditions (any active):


171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
3226.10-SE5989
5031.10-SE5982
Ambient air pressure < 75 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 417


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Ambient air temperature < -6.7 °C


Aftertreatment Outlet NOx sensor reading is not valid due to internal control loops within the sensor
being unstable, or active faults detected by the sensor, or the sensor's battery supply voltage is
outside the desired range or dewpoint temperature not met. (See RefCond167.8.)

Pause Conditions (any active):


Virtual SCR Inlet O2% ≥ 17 %
Exhaust flow ≤ 100 g/sec
Engine is in motoring condition

Malfunction Thresholds (all active):


The fail sample percentage is above 30 %. Where the fail sample percentage is calculated as: The
number of fail samples that the SCR Outlet O2 is above 18 % / The total number of the samples (600
counts) * 100%
The Min/Max Delta of the sampled SCR Outlet O2% during the sampling period is below 3 %. The
sampling period starts when the diagnostic was enabled for 15 sec, and ends when the number of
samples reached 600 counts.

Cummins Inc. Revision Date: March 30, 2017 418


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

338. 3226.2-SE7613: Aftertreatment 1 Outlet NOx Sensor - Data Erratic,


Intermittent, or Incorrect
The system has detected that the aftertreatment outlet NOx sensor output is in-range, but not varying
as expected (i.e. stuck-in-range)

Monitor Operation:
DTC 3226.2-SE7613
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3226.9-SE2488
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
SCR inlet NOx flow rate ≥ 0.1 g/sec
Rate of change of SCR-inlet NOx flow rate > 0.06 g/sec2
Exhaust mass flow rate > 100 g/sec
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
SCR Inlet NOx flow rate status is valid.

Cummins Inc. Revision Date: March 30, 2017 419


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3228.2-SE6021
5031.10-SE5982
3226.10-SE5989
3226.9-SE2488
Aftertreatment Inlet NOx sensor reading is not valid. (See RefCond69.9.)
SCR Inlet NOx flow rate status is not valid.

Malfunction Thresholds (all active):


Since the monitor has become Enabled:
The maximum SCR outlet NOx concentration – minimum SCR outlet NOx concentration < 2 ppm
SCR inlet NOx accumulated mass > 3 g

Cummins Inc. Revision Date: March 30, 2017 420


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

339. 251.10-SE4760: Real Time Clock - Abnormal Rate of Change


Engine Off Timer Stuck

Monitor Operation:
DTC 251.10-SE4760
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Coolant Temperature at the prior powerdown ≥ 70 °C
Powerdown Coolant Temperature - Startup Coolant Temperature ≥ 10 °C

Abort Conditions (any active):


3597.2-SE294
Battery power to the ECM has been removed since the prior power down.

Malfunction Thresholds (all active):


Number of times that the engine off timer displays the same value ≥ 5 counts

Cummins Inc. Revision Date: March 30, 2017 421


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

340. 251.10-SE4759: Real Time Clock - Abnormal Rate of Change


ECM real time clock data has an erratic update rate.

Monitor Operation:
DTC 251.10-SE4759
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


The diagnostic monitor run time ≥ 721 sec

Abort Conditions (any active):


3597.2-SE294
Battery power to the ECM has been removed since the prior power down.

Malfunction Thresholds (all active):


| Real Time clock elapsed time - 721sec | > 120 sec

Cummins Inc. Revision Date: March 30, 2017 422


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

341. 100.18-SE74: Engine Oil Rifle Pressure - Data Valid But Below
Normal Operating Range - Moderately Severe Level
Engine Oil Rifle Pressure is valid but below normal operating range.

Monitor Operation:
DTC 100.18-SE74
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Time after the engine has started ≥ 30 sec
Engine Speed ≥ 400 RPM

Pause Conditions (any active):


Engine Speed < 400 RPM

Malfunction Thresholds (all active):


Oil Pressure ≤ RefTable116.4

Cummins Inc. Revision Date: March 30, 2017 423


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

342. 100.1-SE279: Engine Oil Rifle Pressure - Data Valid But Below
Normal Operating Range - Most Severe Level
Engine Oil Rifle Pressure is valid but below normal operating range.

Monitor Operation:
DTC 100.1-SE279
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Time after the engine has started ≥ 30 sec
Engine Speed ≥ 400 RPM

Pause Conditions (any active):


Engine Speed < 400 RPM

Malfunction Thresholds (all active):


Oil Pressure ≤ RefTable116.4

Cummins Inc. Revision Date: March 30, 2017 424


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

343. 100.2-SE687: Engine Oil Rifle Pressure - Data Erratic, Intermittent,


or Incorrect
Oil Rifle Pressure sensor is either erratic, intermittent or incorrect.

Monitor Operation:
DTC 100.2-SE687
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):

Abort Conditions (any active):

Malfunction Thresholds (all active):


Oil Pressure > 0 kPa (Gauge) at key on with Engine Speed = 0 RPM
Number of times the Oil Pressure Switch sensor indicates positive Oil Pressure before engine start ≥ 1
counts

Cummins Inc. Revision Date: March 30, 2017 425


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

344. 629.12-SE5344: Engine Control Module Critical Internal Failure -


Bad Intelligent Device or Component
The frequency of the internal oscillator, used as the ECM Fuel System ASIC clock, is incorrect.

Monitor Operation:
DTC 629.12-SE5344
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The internal oscillator, used as the ECM Fuel System ASIC clock, is oscillating at a frequency < 7,812.5
Hz.

Cummins Inc. Revision Date: March 30, 2017 426


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

345. 3597.2-SE294: Power Supply Lost With Ignition On - Data Erratic,


Intermittent, or Incorrect
RAM image storage has not completed for every time that it has started.

Monitor Operation:
DTC 3597.2-SE294
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.04 sec
MIL Activation Criteria OBD No MIL

Malfunction Thresholds (all active):


At powerup, the number of times RAM image storage has started does not match the number of
times RAM image storage has completed.

Cummins Inc. Revision Date: March 30, 2017 427


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

346. 5298.17-SE3545: Aftertreatment Diesel Oxidation Catalyst


Conversion Efficiency - Data Valid But Below Normal Operating
Range - Least Severe Level
Active regeneration of the DPF aborted due to the system detecting a malfunction with the closed loop
temperatue controller using up all of the adjustment allowed.

Monitor Operation:
DTC 5298.17-SE3545
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate after malfunction criteria are met
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
Rate of active/intrusive injection of Hydrocarbons into exhaust > 0.2 g/sec
Ambient Air Temperature > -6.7 °C
Enable conditions for the algorithm that detects an ineffective regeneration of the DPF. (See
RefCond168.1.)

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389

Cummins Inc. Revision Date: March 30, 2017 428


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
Rate of active/intrusive injection of Hydrocarbons into exhaust ≤ 0.2 g/sec
Ambient Air Temperature ≤ -6.7 °C
Abort conditions for the algorithm that detects an ineffective regeneration of the DPF. (See
RefCond169.1.)

Pause Conditions (any active):


Pause conditions for the algorithm that detects an ineffective regeneration of the DPF. (See
RefCond170.5.)
Torque Fueling < 0 mg/stroke

Malfunction Thresholds (all active):


Malfunction criteria for the algorithm that detects an ineffective regeneration of the DPF. (Detection
of ineffective regeneration aborts the current active regeneration of the DPF.) (See RefCond115.5.)
3 unique occurrences of the following conditions during an active regeneration of the DPF, with each
occurrence persisting for a minimum of 60 seconds: (desired DOC outlet temperature - actual DOC
outlet temperature > 15 degC) AND (allowed HC injection command {limited due to tailpipe HC slip
concerns} - desired HC injection command estimated from feed forward control > 0 g/sec) AND [(total
HC injection rate command - allowed HC injection rate > 0 g/sec) OR (HC injection rate before
feedback adjustment - actual HC injection rate after feedback adjustment > 0 g/sec)]

Cummins Inc. Revision Date: March 30, 2017 429


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

347. 5835.9-SE12781: Aftertreatment 1 Particulate Sensor - Abnormal


Update Rate
Detect the loss of the Particulate Matter Sensor Data 1 (PMS C01) message from the Bosch Particulate
Matter Sensor device on the Datalink.

Monitor Operation:
DTC 5835.9-SE12781
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Not[ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


The Particulate Matter Sensor Data 1 (PMS C01) message from the Bosch Particulate Matter Sensor
device on the Datalink was not received.

Cummins Inc. Revision Date: March 30, 2017 430


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

348. 5835.9-SE12782: Aftertreatment 1 Particulate Sensor - Abnormal


Update Rate
Detect the loss of the Particulate Matter Sensor Initialization (PMS C02) message from the Bosch
Particulate Matter Sensor device on the Datalink.

Monitor Operation:
DTC 5835.9-SE12782
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Not[ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


The Particulate Matter Sensor Initialization (PMS C02) message from the Bosch Particulate Matter
Sensor device on the Datalink was not received.

Cummins Inc. Revision Date: March 30, 2017 431


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

349. 5835.9-SE12783: Aftertreatment 1 Particulate Sensor - Abnormal


Update Rate
Detect the loss of the Particulate Matter Sensor Mode 6 Diagnostics (PMS C03) message from the Bosch
Particulate Matter Sensor device on the Datalink.

Monitor Operation:
DTC 5835.9-SE12783
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Not[ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


The Particulate Matter Sensor Mode 6 Diagnostics (PMS C03) message from the Bosch Particulate
Matter Sensor device on the Datalink was not received.

Cummins Inc. Revision Date: March 30, 2017 432


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

350. 5835.9-SE12784: Aftertreatment 1 Particulate Sensor - Abnormal


Update Rate
Detect the loss of the Particulate Matter Sensor Continuous and Semi-Continuous Diagnostics (PMS C04)
message from the Bosch Particulate Matter Sensor device on the Datalink.

Monitor Operation:
DTC 5835.9-SE12784
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Not[ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


The Particulate Matter Sensor Continuous and Semi-Continuous Diagnostics (PMS C04) message from
the Bosch Particulate Matter Sensor device on the Datalink was not received.

Cummins Inc. Revision Date: March 30, 2017 433


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

351. 5835.9-SE12785: Aftertreatment 1 Particulate Sensor - Abnormal


Update Rate
Detect the loss of the Particulate Matter Sensor Data 2 (PMS C05) message from the Bosch Particulate
Matter Sensor device on the Datalink.

Monitor Operation:
DTC 5835.9-SE12785
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2,010 msec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.)

Abort Conditions (any active):


Not[ Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event,
a low battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to
allow reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics. (See RefCond10.4.) ]

Malfunction Thresholds (all active):


The Particulate Matter Sensor Data 2 (PMS C05) message from the Bosch Particulate Matter Sensor
device on the Datalink was not received.

Cummins Inc. Revision Date: March 30, 2017 434


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

352. 7854.12-SE13133: Aftertreatment 1 Diesel Particulate Filter Soot


Sensor Module Voltage Converter - Bad Intelligent Device or
Component
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the output voltage of the
power DC to DC converter is out of range for the PM sensor.

Monitor Operation:
DTC 7854.12-SE13133
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8.7 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.4-SE12917
6778.4-SE12921
5569.3-SE12945
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
6773.16-SE13097
1 sec has elapsed after key switch on.
Battery voltage is within range. (See RefCond26.1.)
DC to DC 8 V Functional range low check status signal is available
DC to DC 8 V Functional range high check status signal is available
DC to DC 12 V Functional range low check status signal is available
DC to DC 12 V Functional range high check status signal is available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is off OR 1 sec has not elapsed after key switch on.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Cummins Inc. Revision Date: March 30, 2017 435


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

DC to DC 8 V Functional range low check status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)
DC to DC 8 V Functional range high check status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)
DC to DC 12 V Functional range low check status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)
DC to DC 12 V Functional range high check status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


Output voltage of PM sensor power DC to DC in 8V mode < 7.2 V OR Output voltage of PM sensor
power DC to DC in 8V mode > 8.8 V OR Output voltage of PM sensor power DC to DC in 12V mode <
10.8 V OR Output voltage of PM sensor power DC to DC in 12V mode > 13.2 V

Cummins Inc. Revision Date: March 30, 2017 436


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

353. 6778.16-SE12924: Aftertreatment 1 Particulate Sensor Power


Supply - Data Valid But Above Normal Operating Range -
Moderately Severe Level
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the sensor boost circuit control
is creating an excessive output voltage.

Monitor Operation:
DTC 6778.16-SE12924
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 9.6 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
PM sensor boost voltage status signal is available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):

Cummins Inc. Revision Date: March 30, 2017 437


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor Inter digital electrode boost voltage status is signal not available (Diagnostic conditions are
met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PM sensor boost circuit voltage > 49.72 V.

Cummins Inc. Revision Date: March 30, 2017 438


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

354. 6778.3-SE12920: Aftertreatment 1 Particulate Sensor Power


Supply - Voltage Above Normal or Shorted to High Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that sensor boost circuit has
shorted to battery.

Monitor Operation:
DTC 6778.3-SE12920
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM Sensor Inter digital electrode boost voltage short to battery check status signal is available

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915

Cummins Inc. Revision Date: March 30, 2017 439


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM Sensor Inter digital electrode boost voltage short to battery check status s signal not available
(Diagnostic conditions are met but signal is yet to process) or Diagnostic is not run (Enabling
conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PM sensor boost circuit voltage > 2 V
((Sensor supply is ON AND PM sensor boost circuit voltage < 41.55 V)
OR (Sensor supply is OFF AND PM sensor boost circuit voltage < 49.71 V)
OR (Sensor supply is ON AND sensor current > 41 microA AND PM sensor boost circuit voltage < 31
V.))

Cummins Inc. Revision Date: March 30, 2017 440


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

355. 6778.4-SE12921: Aftertreatment 1 Particulate Sensor Power


Supply - Voltage Below Normal or Shorted to Low Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that sensor boost circuit has
shorted to ground.

Monitor Operation:
DTC 6778.4-SE12921
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 9.6 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Exhaust gas temperature as measured by the exhaust gas temperature sensor closest to the PM
sensor is above a threshold representing the point at which there is no longer a concern of
condensation on the PM sensor sensing element. (See RefCond25.3.)
PM sensor is in Measurement phase.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM Sensor Inter digital electrode boost voltage short to ground check status signal is available

Cummins Inc. Revision Date: March 30, 2017 441


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
NOT [Exhaust gas temperature as measured by the exhaust gas temperature sensor closest to the PM
sensor is above a threshold representing the point at which there is no longer a concern of
condensation on the PM sensor sensing element. (See RefCond25.3.)]
PM sensor is NOT in Measurement phase.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM Sensor Inter digital electrode boost voltage short to ground check status is signal not available
(Diagnostic conditions are met but signal is yet to process) or Diagnostic is not run (Enabling
conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PM sensor boost circuit voltage < 2 V

Cummins Inc. Revision Date: March 30, 2017 442


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

356. 7329.2-SE12922: Aftertreatment 1 Particulate Sensor Heater


Power Supply - Data Erratic, Intermittent, or Incorrect
The Particulate Matter (PM) Sensor Control Unit (SCU) detected heater power being applied when
heater power is not expected.

Monitor Operation:
DTC 7329.2-SE12922
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Particulate matter sensor heater command is OFF.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater off status signal is available

Abort Conditions (any active):


7321.3-SE12914

Cummins Inc. Revision Date: March 30, 2017 443


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
Particulate matter sensor heater command is ON.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater off status is signal not available (Diagnostic conditions are met but signal is yet to
process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


In PM sensor heater OFF phase, heater current > 0.2 A
In PM sensor heater OFF phase, Heater switch is ON

Cummins Inc. Revision Date: March 30, 2017 444


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

357. 7329.2-SE12923: Aftertreatment 1 Particulate Sensor Heater


Power Supply - Data Erratic, Intermittent, or Incorrect
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the heater resistance of the PM
sensor is less than the lower threshold or greater than the higher threshold on power-up.

Monitor Operation:
DTC 7329.2-SE12923
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 12 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
-30 degC < PM sensor heater temperature < 150 degC
While the diagnostic is enabled, (maximum observed heater temperature - minimum observed heater
temperature) < 150 degC.
Battery voltage is within range. (See RefCond26.1.)
NOT[Abort condition to disable the diagnostics when ambient temperature or pressure are outside
limit threshold values. (See RefCond132.7.)]

Cummins Inc. Revision Date: March 30, 2017 445


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater startup status signal is available

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
PM sensor heater temperature < -30 degC.
PM sensor heater temperature > 150 degC.
NOT [Battery voltage is within range. (See RefCond26.1.)]
While the diagnostic is enabled, (maximum observed heater temperature - minimum observed heater
temperature) > 150 degC.
Abort condition to disable the diagnostics when ambient temperature or pressure are outside limit
threshold values. (See RefCond132.7.)
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater startup status is signal not available (Diagnostic conditions are met but signal is yet
to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12783

Cummins Inc. Revision Date: March 30, 2017 446


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


The PM sensor heater resistance < RefTable47.1
OR
The PM sensor heater resistance > RefTable48.1

Cummins Inc. Revision Date: March 30, 2017 447


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

358. 7321.3-SE12914: Aftertreatment 1 Particulate Sensor Heater High


Side Driver Circuit - Voltage Above Normal or Shorted to High
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the high side driver of the PM
sensor heater has shorted to battery.

Monitor Operation:
DTC 7321.3-SE12914
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
PM sensor heater is OFF.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater high short to battery status signal is available

Cummins Inc. Revision Date: March 30, 2017 448


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
PM sensor heater is ON.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater high short to battery status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


The PM sensor heater high side driver voltage > 7 V

Cummins Inc. Revision Date: March 30, 2017 449


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

359. 7321.4-SE12915: Aftertreatment 1 Particulate Sensor Heater High


Side Driver Circuit - Voltage Below Normal or Shorted to Low
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the high side driver of the PM
sensor heater has shorted to ground.

Monitor Operation:
DTC 7321.4-SE12915
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 9 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
PM sensor heater is ON.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater high short to ground status signal is available

Cummins Inc. Revision Date: March 30, 2017 450


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
PM sensor heater is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater high short to ground status is signal not available (Diagnostic conditions are met
but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


The PM sensor heater high side driver voltage < 3 V

Cummins Inc. Revision Date: March 30, 2017 451


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

360. 7323.4-SE12916: Aftertreatment 1 Particulate Sensor Heater Low


Side Driver Circuit - Voltage Below Normal or Shorted to Low
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the PM sensor heater low side
has an open circuit.

Monitor Operation:
DTC 7323.4-SE12916
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 7.6 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater low short to battery status signal is available

Cummins Inc. Revision Date: March 30, 2017 452


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater low short to battery status is signal not available (Diagnostic conditions are met but
signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


The PM sensor heater low side driver voltage > 3 V

Cummins Inc. Revision Date: March 30, 2017 453


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

361. 7321.4-SE12917: Aftertreatment 1 Particulate Sensor Heater High


Side Driver Circuit - Voltage Below Normal or Shorted to Low
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the PM sensor heater has an
open circuit.

Monitor Operation:
DTC 7321.4-SE12917
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 9 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
PM sensor heater is ON.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor heater open loop status signal is available

Cummins Inc. Revision Date: March 30, 2017 454


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
PM sensor heater is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor heater open loop status is signal not available (Diagnostic conditions are met but signal is
yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


The PM sensor heater current < 0.5 A

Cummins Inc. Revision Date: March 30, 2017 455


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

362. 5835.21-SE13109: Aftertreatment 1 Particulate Sensor - Data Not


Rational - Drifted Low
The system has detected a clog in the protection tube of the Particulate Matter (PM) sensor or improper
installation of PM sensor in the exhaust.

Monitor Operation:
DTC 5835.21-SE13109
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
6780.2-SE13095
6780.2-SE13096
Key switch is ON.
A decision has not been made by this diagnostic in the current drive cycle.
Ambient air temperature sensor status is data valid.
Ambient Pressure is data valid.
Ambient air pressure > 75 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 456


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Ambient air temperature > -6.7 °C

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
6780.2-SE13095
6780.2-SE13096
Key Switch is OFF.
A decision has been made by this diagnostic in the current drive cycle.
Ambient air temperature sensor status is NOT data valid.
Ambient air pressure < 75 kPa(absolute)
Ambient air temperature ≤ -6.7 °C
Ambient Pressure is NOT data valid.

Pause Conditions (any active):


Absolute exhaust gas acceleration < 0.5 m/sec2 OR absolute exhaust gas acceleration > 5 m/sec2.
Sensor supply voltage status is NOT data valid.
PM sensor is not in protection heating phase for 10 sec.
Average of three exhaust gas temperatures is less than a calibratable threshold OR ECM Off Time is
data valid and greater than a calibratable threshold (See RefCond171.1.)
Exhaust gas temperature < -6.7 degC OR Exhaust gas temperature > 180 degC
Exhaust gas temperature status is NOT data valid.
Battery voltage < 11 V OR battery voltage > 16.5 V.

Cummins Inc. Revision Date: March 30, 2017 457


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Exhaust gas velocity > 60 m/s for 2 sec.


The exhaust velocity status is NOT data valid.

Malfunction Thresholds (all active):


Accumulated change of heater voltage < 0.1 V
Accumulated exhaust gas acceleration > 30 m/sec

Cummins Inc. Revision Date: March 30, 2017 458


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

363. 5835.3-SE12918: Aftertreatment 1 Particulate Sensor Circuit -


Voltage Above Normal or Shorted to High Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the sensing element has
shorted to battery.

Monitor Operation:
DTC 5835.3-SE12918
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor out of range high short to battery status is Data Valid.

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916

Cummins Inc. Revision Date: March 30, 2017 459


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7321.4-SE12917
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
PM sensor out of range high short to battery status is Data Invalid
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


When PM sensor measurement is active, PM sensor measurement current > 41uA for 8 sec in a
sequence for 2 counts OR PM Sensor measurement and regeneration is not active, PM sensor
measurement current > 41uA for 8 sec

Cummins Inc. Revision Date: March 30, 2017 460


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

364. 5835.4-SE12919: Aftertreatment 1 Particulate Sensor Circuit -


Voltage Below Normal or Shorted to Low Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the sensing element has
shorted to ground.

Monitor Operation:
DTC 5835.4-SE12919
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
770 degC < PM sensor probe temperature < 800 degC.
OR
580 degC < PM sensor probe temperature < 670 degC
PM sensor Regeneration phase is active.
Battery voltage is within range. (See RefCond26.1.)
NOT[Abort condition to disable the diagnostics when ambient temperature or pressure are outside
limit threshold values. (See RefCond132.7.)]

Cummins Inc. Revision Date: March 30, 2017 461


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor short to battery out of range low check status signal is available

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
PM sensor probe temperature < 770 degC.
PM sensor probe temperature > 800 degC.
PM sensor probe temperature < 580 degC.
PM sensor probe temperature > 670 degC.
PM sensor Regeneration phase is not active.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
Abort condition to disable the diagnostics when ambient temperature or pressure are outside limit
threshold values. (See RefCond132.7.)
PM sensor short to battery out of range low status is signal not available (Diagnostic conditions are
met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU side are not met)

Pause Conditions (any active):


5835.9-SE12783

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 462


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

PM sensor PM measurement current < 2 microA


Change in sensor out current at two different sensor temperatures < 0.094 microA

Cummins Inc. Revision Date: March 30, 2017 463


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

365. 6777.10-SE12950: Aftertreatment 1 Particulate Sensor Detection


Status - Abnormal Rate of Change
The electronic control module has detected that the Particulate Matter (PM) sensor status is persistently
not data valid.

Monitor Operation:
DTC 6777.10-SE12950
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5835.3-SE12918
5835.4-SE12919
6778.16-SE12924
6778.3-SE12920
6778.4-SE12921
7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
7329.2-SE12922
7329.2-SE12923
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
6773.7-SE13070
5835.21-SE13109
5569.16-SE13115
6773.16-SE13097
6780.2-SE13095
6780.2-SE13096
7854.12-SE13133

Cummins Inc. Revision Date: March 30, 2017 464


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Key switch is ON.


PM sensor Measurement phase is active.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Tempereture sensors 1 and 2 are not plausible in higher range check status signal is available
Tempereture sensors 1 and 2 are not plausible in lower range check status signal is available

Abort Conditions (any active):


5835.3-SE12918
5835.4-SE12919
6778.16-SE12924
6778.3-SE12920
6778.4-SE12921
7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
7329.2-SE12922
7329.2-SE12923
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
6773.7-SE13070
5835.21-SE13109
5569.16-SE13115
6773.16-SE13097
6780.2-SE13095
6780.2-SE13096
7854.12-SE13133
PM sensor Measurement phase is not active.
Key switch is OFF.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
Tempereture sensors 1 and 2 are not plausible in lower range check status is signal not available
(Diagnostic conditions are met but signal is yet to process)

Cummins Inc. Revision Date: March 30, 2017 465


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Tempereture sensors 1 and 2 are not plausible in lhigher range check status is signal not available
(Diagnostic conditions are met but signal is yet to process)

Pause Conditions (any active):


5835.9-SE12781

Malfunction Thresholds (all active):


Within a moving time window of 300 seconds, the percentage of time that the PM sensor signal is not
data valid > 50 %.

Cummins Inc. Revision Date: March 30, 2017 466


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

366. 7854.2-SE13054: Aftertreatment 1 Particulate Sensor Module


Battery Voltage Supply - Data Erratic, Intermittent, or Incorrect
The system has detected an intermittent power supply voltage drop that results in an internal reset to
the Particulate Matter (PM) sensor a calibratable number of times within a calibratable period of time.

Monitor Operation:
DTC 7854.2-SE13054
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Engine running condition (See RefCond368.1.) for 60 sec.

Abort Conditions (any active):


7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT[Engine running condition (See RefCond368.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Pause Conditions (any active):


5835.9-SE12782

Malfunction Thresholds (all active):


The number of PM sensor reset events ≥ 3 counts for 600 sec.

Cummins Inc. Revision Date: March 30, 2017 467


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

367. 6773.7-SE13070: Aftertreatment 1 Particulate Sensor


Regeneration Status - Mechanical System Not Responding or Out
of Adjustment
The system has detected an unsuccessful transition from regeneration phase to measurement phase of
the Particulate Matter (PM) sensor.

Monitor Operation:
DTC 6773.7-SE13070
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 320 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5835.21-SE13109
6780.2-SE13095
6780.2-SE13096

Cummins Inc. Revision Date: March 30, 2017 468


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


7321.3-SE12914
7321.4-SE12915
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5835.21-SE13109
6780.2-SE13095
6780.2-SE13096

Pause Conditions (any active):


NOT [Exhaust gas temperature as measured by the exhaust gas temperature sensor closest to the PM
sensor is above a threshold representing the point at which there is no longer a concern of
condensation on the PM sensor sensing element. (See RefCond25.3.)]
PM sensor is not in sensor Regeneration phase.
Battery voltage < 11 V since start of sensor Regeneration.
Within a 0.2 sec window, battery voltage > 16.5 V for ≥ 0.2 sec.
Sensor supply voltage is NOT data valid.
Exhaust flow velocity is NOT data valid.
Exhaust temperature is NOT data valid.

Malfunction Thresholds (all active):


Particulate Matter Sensor heater can not maintain 785°C for 43 sec.

Cummins Inc. Revision Date: March 30, 2017 469


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

368. 6773.16-SE13097: Aftertreatment 1 Particulate Sensor


Regeneration Status - Data Valid But Above Normal Operating
Range - Moderately Severe Level
The system has detected that the Particulate Matter (PM) sensor has a positive offset.

Monitor Operation:
DTC 6773.16-SE13097
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 18 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


6778.4-SE12921
7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
6773.7-SE13070
5835.21-SE13109
5569.16-SE13115
6780.2-SE13095
6780.2-SE13096
PM sensor has successfully transitioned from Regeneration phase to Measurement phase.

Cummins Inc. Revision Date: March 30, 2017 470


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

30.5 V < PM sensor Inter Digital Electrode (IDE) supply voltage < 49.72 V.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


6778.4-SE12921
7321.3-SE12914
7323.4-SE12916
7321.4-SE12917
5835.3-SE12918
5835.4-SE12919
6778.3-SE12920
6778.4-SE12921
7329.2-SE12922
7329.2-SE12923
6778.16-SE12924
5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
5569.2-SE12963
6780.3-SE12948
6780.4-SE12949
7854.12-SE13133
7854.2-SE13054
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
6773.7-SE13070
5835.21-SE13109
5569.16-SE13115
6780.2-SE13095
6780.2-SE13096
PM sensor has not successfully transitioned from Regeneration phase to Measurement phase.
NOT [Battery voltage is within range. (See RefCond26.1.)]
PM sensor Inter Digital Electrode (IDE) supply voltage < 30.5 V
PM sensor Inter Digital Electrode (IDE) supply voltage > 49.72 V.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Pause Conditions (any active):


5835.9-SE12783

Cummins Inc. Revision Date: March 30, 2017 471


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


PM sensor PM measurement current > 5 microA.

Cummins Inc. Revision Date: March 30, 2017 472


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

369. 5569.2-SE12963: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature - Data Erratic, Intermittent, or
Incorrect
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature sensor 1 and PCB temperature sensor 2 readings are not consistent with each other.

Monitor Operation:
DTC 5569.2-SE12963
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6.5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


5569.4-SE12944
5569.3-SE12945
5569.4-SE12946
5569.3-SE12947
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Cummins Inc. Revision Date: March 30, 2017 473


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PCB temperature sensor 1 - PCB temperature sensor 2 < -13 degC OR PCB temperature sensor 1 - PCB
temperature sensor 2 > 20 degC.

Cummins Inc. Revision Date: March 30, 2017 474


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

370. 5569.3-SE12945: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature 1 Circuit - Voltage Above Normal
or Shorted to High Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature sensor 1 is shorted to battery.

Monitor Operation:
DTC 5569.3-SE12945
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5569.4-SE12944
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
PM sensor printed circuit board tempereture sensor 1 high check status signal is available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


5569.4-SE12944
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor printed circuit board tempereture sensor 1 high status is signal not available (Diagnostic
conditions are met but signal is yet to process)
NOT[Engine running condition (See RefCond368.1.)]

Cummins Inc. Revision Date: March 30, 2017 475


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PCB temperature sensor 1 ADC raw voltage > 4.97 V

Cummins Inc. Revision Date: March 30, 2017 476


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

371. 5569.4-SE12944: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature 1 Circuit - Voltage Below Normal
or Shorted to Low Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature sensor 1 is shorted to ground.

Monitor Operation:
DTC 5569.4-SE12944
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5569.3-SE12945
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
PM sensor printed circuit board tempereture sensor 1 low check status signal is available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


5569.3-SE12945
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor printed circuit board tempereture sensor 1 low status is signal not available (Diagnostic
conditions are met but signal is yet to process)
NOT[Engine running condition (See RefCond368.1.)]

Cummins Inc. Revision Date: March 30, 2017 477


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PCB temperature sensor 1 ADC raw voltage < 0.3 V

Cummins Inc. Revision Date: March 30, 2017 478


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

372. 5569.3-SE12947: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature 2 Circuit - Voltage Above Normal
or Shorted to High Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature sensor 2 is shorted to battery.

Monitor Operation:
DTC 5569.3-SE12947
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5569.4-SE12946
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
PM sensor printed circuit board tempereture sensor 2 high check status signal is available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


5569.4-SE12946
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor printed circuit board tempereture sensor 2 high status is signal not available (Diagnostic
conditions are met but signal is yet to process)
NOT[Engine running condition (See RefCond368.1.)]

Cummins Inc. Revision Date: March 30, 2017 479


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PCB temperature sensor 2 ADC raw voltage > 4.7 V

Cummins Inc. Revision Date: March 30, 2017 480


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

373. 5569.4-SE12946: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature 2 Circuit - Voltage Below Normal
or Shorted to Low Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature sensor 2 is shorted to ground.

Monitor Operation:
DTC 5569.4-SE12946
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5569.3-SE12947
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
PM sensor printed circuit board tempereture sensor 2 low check status is signal available
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


5569.3-SE12947
5569.2-SE12963
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor printed circuit board tempereture sensor 2 low status is signal not available (Diagnostic
conditions are met but signal is yet to process)
NOT[Engine running condition (See RefCond368.1.)]

Cummins Inc. Revision Date: March 30, 2017 481


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PCB temperature sensor 2 ADC raw voltage < 0.03 V

Cummins Inc. Revision Date: March 30, 2017 482


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

374. 5569.16-SE13115: Aftertreatment 1 Diesel Particulate Filter 1 Soot


Sensor ECU Internal Temperature - Data Valid But Above Normal
Operating Range - Moderately Severe Level
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the Printed Circuit Board (PCB)
temperature is too high.

Monitor Operation:
DTC 5569.16-SE13115
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
Key switch is ON.
Battery voltage is within range. (See RefCond26.1.)
PM sensor functional range check status for tempereture sensor 1 is signal available.
PM sensor functional range check status for tempereture sensor 2 is signal available.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
Key switch is OFF.
NOT [Battery voltage is within range. (See RefCond26.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor functional range check status for tempereture sensor 1 is signal not available (Diagnostic
conditions are met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU
(Sensor Control Unit) side are not met)
PM sensor functional range check status for tempereture sensor 2 is signal not available (Diagnostic
conditions are met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU
(Sensor Control Unit) side are not met)

Pause Conditions (any active):


5835.9-SE12784

Cummins Inc. Revision Date: March 30, 2017 483


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


An over temperature event is a scenario, where PCB temperature sensor 1 > 140 degC FOR > 2
seconds OR PCB temperature sensor 2 > 134degC FOR > 2 seconds. Over temperature event counter
is incremented at the beginning of a new over temperature event or when the present over
temperature event is longer than 1,800 seconds. Diagnostic fault is set when over temperature event
counter reaches 3 counts.

Cummins Inc. Revision Date: March 30, 2017 484


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

375. 6780.2-SE13096: Aftertreatment 1 Diesel Particulate Filter Soot


Temperature Sensor - Data Erratic, Intermittent, or Incorrect
The system has detected that the Particulate Matter (PM) sensor probe temperature is not rational at
key-on.

Monitor Operation:
DTC 6780.2-SE13096
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5835.9-SE12782
5835.9-SE12785
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


5835.9-SE12782
5835.9-SE12785
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Pause Conditions (any active):


5569.16-SE13115
7854.6-SE13051
7854.4-SE13049
7854.3-SE13048
6780.4-SE12949
6780.3-SE12948
ECM off time < 28,800 sec.
ECM off time status is NOT data valid.
Key ON event is not detected.
PM sensor supply voltage is NOT data valid.
PM sensor probe temperature < -40 degC.
PM sensor probe temperature sensor status is NOT data valid.
PM SCU errors are present FOR ≥ 5 sec.
Ambient air pressure status is NOT data valid.
Ambient air pressure < 75 kPa(absolute).
-30 degC > SCR out temperature OR 80 degC < SCR out temperature.

Cummins Inc. Revision Date: March 30, 2017 485


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

SCR out temperature status is NOT data valid.


-30 degC > DPF outlet temperature OR 80 degC < DPF outlet temperature.
DPF outlet temperature status is NOT data valid.
-30 degC > DOC outlet temperature OR 80 degC < DOC outlet temperature.
DOC outlet temperature status is NOT data valid.
Engine running condition (See RefCond368.1.)

Malfunction Thresholds (all active):


|PM sensor probe temperature - average of three exhaust gas temperature sensors| > 70 degC.

Cummins Inc. Revision Date: March 30, 2017 486


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

376. 6780.2-SE13095: Aftertreatment 1 Diesel Particulate Filter Soot


Temperature Sensor - Data Erratic, Intermittent, or Incorrect
The system has detected that the Particulate Matter (PM) sensor probe temperature is not rational
during measurement phase.

Monitor Operation:
DTC 6780.2-SE13095
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 50 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


6780.3-SE12948
6780.4-SE12949
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
6780.2-SE13096
5835.9-SE12781
5835.9-SE12785
Measurement phase of the PM sensor is active.
Elapsed time since the beginning of the Measurement phase of PM sensor ≥ 180 sec.
Modeled temperature status is data valid.
170 degC < Modeled PM Sensortemperature < 400 degC.
PM sensor probe temperature status is data valid.
(|Change in modeled temperature| < 30°C) for 90 sec.
(3.107 mph < vehicle speed < 72.079 mph) for 10 sec.
Flow velocity status is data valid.
(5 m/s < exhaust flow velocity < 30 m/s) for 20 sec.
Engine running condition (See RefCond368.1.)
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
NOT[Abort condition to disable the diagnostics when ambient temperature or pressure are outside
limit threshold values. (See RefCond132.7.)]

Abort Conditions (any active):


6780.3-SE12948
6780.4-SE12949
7854.3-SE13048
7854.4-SE13049

Cummins Inc. Revision Date: March 30, 2017 487


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

7854.6-SE13051
5569.16-SE13115
6780.2-SE13096
5835.9-SE12781
5835.9-SE12785
Measurement phase of PM sensor is NOT active.
Elapsed time since the start of Measurement phase of PM sensor < 180 sec.
PM sensor probe temperature status is NOT data valid.
Modeled temperature status is NOT data valid.
170 degC > modeled PM sensor temperature OR modeled PM sensor temperature > 400 degC.
|Change in modeled temperature| > 30 degC.
(3.107 mph > vehicle speed OR vehicle speed > 72.079 mph) for 5 sec.
(5 m/s > exhaust flow velocity OR exhaust flow velocity > 30 m/s) for 10 sec.
Exhaust flow velocity status is NOT data vaild.
NOT[Engine running condition (See RefCond368.1.)]
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
Abort condition to disable the diagnostics when ambient temperature or pressure are outside limit
threshold values. (See RefCond132.7.)

Malfunction Thresholds (all active):


(PM sensor probe temperature - modeled temperature) > RefTable64.2 °C
OR
(PM sensor probe temperature - modeled temperature) <RefTable64.1 °C

Cummins Inc. Revision Date: March 30, 2017 488


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

377. 6780.3-SE12948: Aftertreatment 1 Diesel Particulate Filter Soot


Temperature Sensor - Voltage Above Normal or Shorted to High
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the PM sensor probe
temperature is shorted to battery.

Monitor Operation:
DTC 6780.3-SE12948
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


6780.4-SE12949
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Battery voltage is within range. (See RefCond26.1.)
Key switch is ON.
800 degC > exhaust gas temperature > -40 degC.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor probe tempereture short to battery check is signal available.

Abort Conditions (any active):


6780.4-SE12949
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
NOT [Battery voltage is within range. (See RefCond26.1.)]
Key switch is OFF.
Exhaust gas temperature > 800 degC.
Exhaust gas temperature < -40 degC.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
PM sensor probe tempereture short to battery check is signal not available (Diagnostic conditions are
met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU (Sensor Control
Unit) side are not met)

Cummins Inc. Revision Date: March 30, 2017 489


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PM sensor probe temperature sensor circuit voltage > 3 V (2,125 degC)

Cummins Inc. Revision Date: March 30, 2017 490


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

378. 6780.4-SE12949: Aftertreatment 1 Diesel Particulate Filter Soot


Temperature Sensor - Voltage Below Normal or Shorted to Low
Source
The Particulate Matter (PM) Sensor Control Unit (SCU) has detected that the PM sensor probe
temperature is shorted to ground.

Monitor Operation:
DTC 6780.4-SE12949
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


6780.3-SE12948
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
Battery voltage is within range. (See RefCond26.1.)
Key switch is ON.
800 degC > exhaust gas temperature > -40 degC.
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]
PM sensor probe tempereture short to ground check status for tempereture sensor 1 is signal
available.

Abort Conditions (any active):


6780.3-SE12948
7854.3-SE13048
7854.4-SE13049
7854.6-SE13051
5569.16-SE13115
NOT [Battery voltage is within range. (See RefCond26.1.)]
Key switch is OFF.
Exhaust gas temperature > 800 degC.
Exhaust gas temperature < -40 degC.
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)

Cummins Inc. Revision Date: March 30, 2017 491


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

PM sensor probe tempereture short to ground check signal is not available (Diagnostic conditions are
met but signal is yet to process) or Diagnostic is not run (Enabling conditions at SCU (Sensor Control
Unit) side are not met)

Pause Conditions (any active):


5835.9-SE12784

Malfunction Thresholds (all active):


PM sensor probe temperature sensor circuit voltage < 0.3 V (-181 degC)

Cummins Inc. Revision Date: March 30, 2017 492


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

379. 7854.3-SE13048: Aftertreatment 1 Diesel Particulate Filter Soot


Sensor Module - Voltage Above Normal or Shorted to High Source
The system has detected that the supply voltage of the Particulate Matter (PM) Sensor Control Unit
(SCU) is greater than the supply voltage of Electronic Control Module (ECM).

Monitor Operation:
DTC 7854.3-SE13048
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 11.5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
PM sensor supply voltage status is data valid.
Keyswitch is ON for > 3 sec.
8.5 V < ECM voltage < 17.2 V.

Abort Conditions (any active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
PM sensor supply voltage status is NOT data valid.
Key Switch is ON for < 3 sec OR Key switch is OFF.
ECM voltage < 8.5 V OR ECM voltage > 17.2 V.

Malfunction Thresholds (all active):


SCU voltage - ECM voltage > 1,100 mV AND (ECM voltage > 15,000 mV) OR SCU voltage - ECM voltage
> 2,100 mV AND (ECM voltage < 15,000 mV AND ECM voltage ≥ 11,700 mV) OR SCU voltage - ECM
voltage > 3,000 mV AND (ECM voltage < 15,000 mV AND ECM voltage < 11,700 mV)

Cummins Inc. Revision Date: March 30, 2017 493


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

380. 7854.4-SE13049: Aftertreatment 1 Diesel Particulate Filter Soot


Sensor Module - Voltage Below Normal or Shorted to Low Source
The system has detected that the supply voltage of the Particulate Matter (PM) Sensor Control Unit
(SCU) is less than the supply voltage of Electronic Control Module (ECM).

Monitor Operation:
DTC 7854.4-SE13049
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 11.5 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
PM sensor supply voltage status is data valid.
Key switch is ON for > 3 sec.
8.5 V < ECM voltage < 17.2 V.

Abort Conditions (any active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
PM sensor supply voltage status is NOT data valid.
Key Switch is ON for < 3 sec OR Key switch is OFF.
ECM voltage < 8.5 V OR ECM voltage > 17.2 V.

Malfunction Thresholds (all active):


(ECM voltage - SCU voltage) > 3,000 mV AND (ECM voltage > 15,000 mV) OR (ECM voltage - SCU
voltage) > 2,600 mV AND (ECM voltage < 15,000 mV AND ECM voltage ≥ 11,700 mV) OR (ECM voltage
- SCU voltage > 1,900 mV AND ECM voltage < 11,700 mV)

Cummins Inc. Revision Date: March 30, 2017 494


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

381. 7854.6-SE13051: Aftertreatment 1 Diesel Particulate Filter Soot


Sensor Module - Current Above Normal or Grounded Circuit
The system has detected that the power supply line of the Particulate Matter (PM) Sensor Control Unit
(SCU) has too high of a resistance.

Monitor Operation:
DTC 7854.6-SE13051
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
Particulate matter sensor supply voltage status is data valid.
Key switch is ON for > 3 sec
8.5 V < ECM voltage < 17.2 V
Heater PWM duty cycle status is data valid.
Heater PWM duty cycle > 23 %
NOT[Condition to abort the diagnostic based on the value of battery voltage and engine cranking
state (See RefCond197.18.)]

Abort Conditions (any active):


5835.9-SE12781
5835.9-SE12785
168.15-SE297
168.17-SE296
5569.16-SE13115
Particulate matter sensor supply voltage status is Data Invalid
Key Switch is ON for < 3 sec OR Key switch is OFF
Heater PWM duty cycle status is data Invalid
Heater PWM duty cycle < 23 %
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state
(See RefCond197.18.)
ECM voltage < 8.5 V OR ECM voltage > 17.2 V.

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 495


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

((SCU voltage - ECM voltage > 1,100 mV OR ECM voltage - SCU Voltage> 3,000 mV) AND (ECM voltage
> 15,000 mV)) OR ((SCU voltage - ECM voltage > 2,100 mV OR ECM voltage - SCU Voltage > 2,600 mV)
AND (11,700 mV ≤ECM voltage ≤ 15,000 mV)) OR ((SCU voltage - ECM voltage > 3,000 mV OR ECM
voltage - SCU Voltage > 1,900 mV) AND (ECM voltage < 11,700 mV))

Cummins Inc. Revision Date: March 30, 2017 496


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

382. 629.12-SE217: Engine Control Module Warning Internal Hardware


Failure - Bad Intelligent Device or Component
ECM does not power down when the ignition is off.

Monitor Operation:
DTC 629.12-SE217
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.04 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The ECM stays powered on after the ignition is turned off.

Cummins Inc. Revision Date: March 30, 2017 497


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

383. 4375.2-SE12526: Aftertreatment 1 Diesel Exhaust Fluid Pump Drive


Percentage - Data Erratic, Intermittent, or Incorrect
The monitor checks the persistence of DEF Dosing Module Pump command stability.

Monitor Operation:
DTC 4375.2-SE12526
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 counts
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond477.38.)

Abort Conditions (any active):


NOT [ The inverted disable conditions for the diagnostic are specified as follows (See RefCond456.2.) ]

Malfunction Thresholds (all active):


Within each intrusive DEF dosing window, integral pump command is > 60 % OR rate of change of
integral pump command is > 15 %/sec AND 15 seconds have elapsed when commanding 0.9 ml/sec.
OR
Within each intrusive DEF dosing window, integral pump command is > 60 % OR rate of change of
integral pump command is > 15 %/sec AND 15 seconds have elapsed when commanding 0 ml/sec.

Cummins Inc. Revision Date: March 30, 2017 498


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

384. 651.7-SE3104: Injector Solenoid Driver Cylinder 1 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 1
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 651.7-SE3104
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 499


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


Estimated Average Fuel Quantity Deviation >= 12 mg/stroke OR Estimated Average Fuel Quantity
Deviation <= -15 mg/stroke Where: Estimated Average Fuel Quantity Deviation is calculated by taking
sample measurement for each injector during engine motoring condition and by averaging the
samples when the number of samples is equal to 10. After that all the new sample measurement is
added to the estimated average fueling quantity as a moving average fuel quantity for each injector.
The value of estimated average fuel quantity deviation is rested back to zero whenever there is a new
drive cycle.

Cummins Inc. Revision Date: March 30, 2017 500


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

385. 652.7-SE3105: Injector Solenoid Driver Cylinder 2 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 2
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 652.7-SE3105
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
652.5-SE917
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
652.5-SE917
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 501


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


( (Estimated Average Fuel Quantity Deviation >= 12 )mg/stroke) OR ( (Estimated Average Fuel
Quantity Deviation <= -15) mg/stroke) Where: Estimated Average Fuel Quantity Deviation is
calculated by taking sample measurement for each injector during engine motoring condition and by
averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is rested back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 502


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

386. 653.7-SE3102: Injector Solenoid Driver Cylinder 3 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 3
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 653.7-SE3102
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
653.5-SE918
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
653.5-SE918
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 503


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


( (Estimated Average Fuel Quantity Deviation >= 12 )mg/stroke) OR ( (Estimated Average Fuel
Quantity Deviation <= -15) mg/stroke) Where: Estimated Average Fuel Quantity Deviation is
calculated by taking sample measurement for each injector during engine motoring condition and by
averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is rested back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 504


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

387. 654.7-SE3106: Injector Solenoid Driver Cylinder 4 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 4
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 654.7-SE3106
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
654.5-SE919
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
654.5-SE919
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 505


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


( (Estimated Average Fuel Quantity Deviation >= 12 )mg/stroke) OR ( (Estimated Average Fuel
Quantity Deviation <= -15) mg/stroke) Where: Estimated Average Fuel Quantity Deviation is
calculated by taking sample measurement for each injector during engine motoring condition and by
averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is rested back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 506


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

388. 655.7-SE3107: Injector Solenoid Driver Cylinder 5 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 5
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 655.7-SE3107
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
655.5-SE920
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
655.5-SE920
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 507


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


( (Estimated Average Fuel Quantity Deviation >= 12 )mg/stroke) OR ( (Estimated Average Fuel
Quantity Deviation <= -15) mg/stroke) Where: Estimated Average Fuel Quantity Deviation is
calculated by taking sample measurement for each injector during engine motoring condition and by
averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is rested back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 508


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

389. 656.7-SE3108: Injector Solenoid Driver Cylinder 6 - Mechanical


System Not Responding or Out of Adjustment
Detect fuel system injection fueling error when the estimated injector fuel quantity for injector 6
deviates from the desired injector fuel commanded quantity by more than the calibrated threshold limit.

Monitor Operation:
DTC 656.7-SE3108
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediately
MIL Activation Criteria 2 trips

Entry Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
656.5-SE921
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is in WARM State.
Engine is in any of the following States:
Engine is in either RUN State or BRAKING State.
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)

Pause Conditions (any active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
656.5-SE921
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523

Cummins Inc. Revision Date: March 30, 2017 509


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1347.3-SE965, 1347.4-SE966
1347.2-SE915
5571.0-SE914
157.7-SE7209, 157.7-SE7211
Engine Speed ≤ 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is greater than or
equal to 3 sec.
Engine is not operating in any of the following thermal management modes:
Normal Mode.
SCR Thermal Management mode (more information available in AECD 13-2).
Engine is not in WARM State.
Engine is not in RUN State and engine is not in BRAKING State.
NOT(OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.))

Malfunction Thresholds (all active):


( (Estimated Average Fuel Quantity Deviation >= 12 )mg/stroke) OR ( (Estimated Average Fuel
Quantity Deviation <= -15) mg/stroke) Where: Estimated Average Fuel Quantity Deviation is
calculated by taking sample measurement for each injector during engine motoring condition and by
averaging the samples when the number of samples is equal to 10. After that all the new sample
measurement is added to the estimated average fueling quantity as a moving average fuel quantity
for each injector. The value of estimated average fuel quantity deviation is rested back to zero
whenever there is a new drive cycle.

Cummins Inc. Revision Date: March 30, 2017 510


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

390. 629.12-SE33: Engine Control Module Critical Internal Failure - Bad


Intelligent Device or Component
The write to ECM RAM imaged data block has failed.

Monitor Operation:
DTC 629.12-SE33
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.04 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The checksum of the flash data block does not equal to the checksum of its ram imaged data block on
a separate occurrences.

Cummins Inc. Revision Date: March 30, 2017 511


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

391. 630.12-SE5340: Engine Control Module Calibration Memory - Bad


Intelligent Device or Component
Data mismatch between non-volatile memory and its RAM image.

Monitor Operation:
DTC 630.12-SE5340
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


Data in Flash memory does not match its image in RAM on 125 separate occurrences.

Cummins Inc. Revision Date: March 30, 2017 512


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

392. 4331.16-SE12528: Aftertreatment 1 Diesel Exhaust Fluid Actual


Dosing Quantity - Data Valid But Above Normal Operating Range -
Moderately Severe Level
The monitor checks whether the DEF Dosing Module Injector valve is over-dosing based on the slope
calculated using average percent injector ON time and average percent pump command during intrusive
DEF dosing window

Monitor Operation:
DTC 4331.16-SE12528
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond477.38.)

Abort Conditions (any active):


NOT [ The inverted disable conditions for the diagnostic are specified as follows (See RefCond456.2.) ]

Malfunction Thresholds (all active):


Within intrusive DEF dosing window, (Delta percent Injector ON time between two different dosing
levels after pump command has become stable) / (Delta percent pump command between two
different dosing levels after pump command has become stable) < 1.4 (unitless).

Cummins Inc. Revision Date: March 30, 2017 513


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

393. 4331.18-SE12527: Aftertreatment 1 Diesel Exhaust Fluid Actual


Dosing Quantity - Data Valid But Below Normal Operating Range -
Moderately Severe Level
The monitor checks whether the DEF Dosing Module Injector valve is under-dosing based on the slope
calculated using average percent injector ON time and average percent pump command during intrusive
DEF dosing window

Monitor Operation:
DTC 4331.18-SE12527
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond477.38.)

Abort Conditions (any active):


NOT [ The inverted disable conditions for the diagnostic are specified as follows (See RefCond456.2.) ]

Malfunction Thresholds (all active):


Within intrusive DEF dosing window, (Delta percent Injector ON time between two different dosing
levels after pump command has become stable) / (Delta percent pump command between two
different dosing levels after pump command has become stable) > 3.2 (unitless).

Cummins Inc. Revision Date: March 30, 2017 514


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

394. 974.3-SE1367: Remote Accelerator Pedal or Lever Position Sensor


1 Circuit - Voltage Above Normal or Shorted to High Source
Remote Accelerator Out-of-Range High

Monitor Operation:
DTC 974.3-SE1367
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Remote Accelerator Position Sensor Value > 4.37 V (100 %)

Cummins Inc. Revision Date: March 30, 2017 515


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

395. 974.4-SE1368: Remote Accelerator Pedal or Lever Position Sensor


1 Circuit - Voltage Below Normal or Shorted to Low Source
Remote Accelerator Out-of-Range Low

Monitor Operation:
DTC 974.4-SE1368
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Remote Accelerator Position Sensor Value < 0.132 V (0 %)

Cummins Inc. Revision Date: March 30, 2017 516


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

396. 91.3-SE63: Accelerator Pedal or Lever Position Sensor 1 Circuit -


Voltage Above Normal or Shorted to High Source
Primary Accelerator Pedal Position Out-of-Range High

Monitor Operation:
DTC 91.3-SE63
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


91.4-SE64
3512.3-SE817
3512.4-SE815

Pause Conditions (any active):


91.4-SE64
3512.3-SE817
3512.4-SE815

Malfunction Thresholds (all active):


Primary Accelerator Pedal Position Sensor Value > 4.467 V (100 %)

Cummins Inc. Revision Date: March 30, 2017 517


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

397. 91.4-SE64: Accelerator Pedal or Lever Position Sensor 1 Circuit -


Voltage Below Normal or Shorted to Low Source
Primary Accelerator Pedal Position Out-of-Range Low

Monitor Operation:
DTC 91.4-SE64
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3512.3-SE817
3512.4-SE815

Pause Conditions (any active):


3512.3-SE817
3512.4-SE815

Malfunction Thresholds (all active):


Primary Accelerator Pedal Position Sensor Value < 0.826 V (0 %)

Cummins Inc. Revision Date: March 30, 2017 518


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

398. 4363.0-SE2889: Aftertreatment 1 SCR Outlet Temperature - Data


Valid But Above Normal Operating Range - Most Severe Level
The SCR catalyst exhibits an exothermic behavior (i.e. there is a large temperature difference across the
SCR catalyst) for a sustained period of time.

Monitor Operation:
DTC 4363.0-SE2889
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
5862.2-SE2895
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
4363.2-SE3785
SCR outlet temperature ≥ 200 °C
SCR inlet/midbed temperature ≥ 200 °C

Abort Conditions (any active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
5862.2-SE2895
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
4363.2-SE3785
SCR outlet temperature < 200 °C
SCR inlet/midbed temperature < 200 °C

Malfunction Thresholds (all active):


(Calculated mass flow rate of Oxidant reaching the SCR catalyst > 0.4 g/sec ) AND (exhaust mass flow
rate < 2,000 g/sec) for the period of 60 seconds.
OR
(Calculated mass flow rate of Oxidant reaching the SCR catalyst > 0.4 g/sec ) AND (exhaust mass flow
rate ≥ 2,000 g/sec) for the period of 540 seconds.

Cummins Inc. Revision Date: March 30, 2017 519


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 520


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

399. 4794.31-SE10102: Aftertreatment 1 SCR Catalyst System Missing -


Condition Exists
The system has detected that the NOx converting catalyst has no detectable amount of NOx conversion
capability.

Monitor Operation:
DTC 4794.31-SE10102
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366, 3610.10-SE2983,
3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,

Cummins Inc. Revision Date: March 30, 2017 521


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,


4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
4363.0-SE2889
4363.16-SE5295
3226.2-SE7613
3226.21-SE5978
3226.20-SE5976
3228.2-SE6021
3226.4-SE11104
3226.11-SE11496
3227.20-SE12580
3227.21-SE12581
5394.7-SE7927
4331.16-SE12528
4331.18-SE12527
EGR Off Engine Protection is not active
50 g/s ≤ Exhaust flow rate ≤ 310 g/s
-20 g/s2 ≤ Rate of change of estimated exhaust mass flow≤ 10 g/s2
Aftertreatment inlet NOx ≤ 1,500 PPM
Rate of change of SCR NOx In ≤ 30 ppm/sec
Aftertreatment outlet NOx ≤ 1,500 PPM
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
75 kPa (absolute) ≤ Ambient Air pressure
Ambient Air temperature ≥ -6.7 °C
200 degC ≤ estimated SCR catalyst bed temperature ≤ 450 degC
-2 degC/sec ≤ estimated rate of change of absolute SCR catalyst bed temperature ≤ 2 degC/sec
Ammonia to NOx Ratio (ANR) is ≥ 0.8 (unitless) for 5 sec. The timer to exit this enable condition is
enabled if Ammonia to NOx Ratio (ANR) is ≤ 0.7 (unitless) for 30 sec consecutively.
0.8(unitless) < Filtered Ammonia to NOx ratio < 2.5(unitless) Where filter time constant (tau = 2 sec)
| instantaneous Engine Out NOx concentration - moving average Engine Out NOx concentration | /
moving average Engine Out NOx concentration ≤ 50(ratio) for >= RefTable196.1.
(ANR fraction > 0.9(unitless) AND SCR bed temperature > 200 degC AND SCR bed temperature < 430
degC AND SCR Bed temperature reset condition based on the module off time. (See RefCond129.5.))
for ≥ 30 sec.
KeySwitch event has not occurred for 100 sec.
Urea injection command is > 0.05ml/sec for 100 sec.
OR
Number of decisions of Urea Doser Functional Response Monitor ≥ 3counts AND 5394.7-SE7927 is not
active.
Filtered total fueling is ≥ 16 mg/stroke for 2 sec. Where filter time constant (tau = 2 sec)
Dosing concentration correction is not active

Cummins Inc. Revision Date: March 30, 2017 522


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Intrusive dosing is not active


NOT[Any of the DEF Doser related errors are active. (See RefCond507.1.)]
NOT[Any of the DEF Doser related errors are active. (See RefCond508.1.)]

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366, 3610.10-SE2983,
3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
4363.0-SE2889
4363.16-SE5295
3226.2-SE7613
3226.21-SE5978
3226.20-SE5976
3228.2-SE6021

Cummins Inc. Revision Date: March 30, 2017 523


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3226.4-SE11104
3226.11-SE11496
3227.20-SE12580
3227.21-SE12581
5394.7-SE7927
4331.16-SE12528
4331.18-SE12527
EGR Off Engine Protection is active
Aftertreatment state is not equal to Base mode (Normal mode)
Intrusive dosing is active
Dosing concentration correction is active
Any of the DEF Doser related errors are active. (See RefCond507.1.)
Any of the DEF Doser related errors are active. (See RefCond508.1.)

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
Estimated SCR catalyst bed temperature < 200 degC OR estimated SCR catalyst bed temperature >
450 degC
Aftertreatment inlet NOx > 1,500 PPM
Aftertreatment outlet NOx > 1,500 PPM
Ambient air temperature < -6.7 °C
Exhaust flow rate < 50 g/s OR Exhaust flow rate > 310 g/s
Ambient Air pressure < 75 kPa (absolute)
Aftertreatment Outlet NOx sensor reading is not valid due to internal control loops within the sensor
being unstable, or active faults detected by the sensor, or the sensor's battery supply voltage is
outside the desired range or dewpoint temperature not met. (See RefCond93.11.)
SCR Bed temperature reset condition based on the module off time. (See RefCond172.5.)
Rate of change of estimated SCR bed temperature > 2 degC/sec OR Rate of change of estimated SCR
bed temperature < -2 degC/sec
Rate of change of estimated exhaust mass flow> 10g/s2 OR Rate of change of estimated exhaust mass
flow < -20g/s2
Rate of change of SCR NOx In ≥ 30 ppm/sec
Exhaust Flow Rate is ≤ 50g/sec for a minimum cumulative time of 30 sec. The timer to exit this pause
condition is enabled if the Exhaust Flow Rate is ≥ 55g/sec for 5 sec
Estimated SCR catalyst bed temperature rate of change is > RefTable59.6. Pause condition is active for
a minimum cumulative time of RefTable58.8.The timer to exit this pause condition is enabled if the

Cummins Inc. Revision Date: March 30, 2017 524


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

estimated SCR catalyst bed temperature has decreased by at least 0 degC from its maximum
temperature value.
Estimated SCR catalyst bed temperature rate of change is > RefTable59.6. Pause condition is active
for a minimum cumulative time of RefTable60.5. The timer to exit this pause condition is enabled if
the estimated SCR catalyst bed temperature rate of change is < RefTable59.6.
Filtered (tau = 2 sec) Ammonia to NOx ratio (ANR) < 0.8(unitless) OR Filtered (tau = 2 sec) Ammonia to
NOx ratio (ANR) > 2.5(unitless)
Ammonia to NOx Ratio (ANR) Feedback is ≤ 0.7 (unitless) for 30 sec. The timer to exit this pause
condition is enabled if Ammonia to NOx Ratio (ANR) is > 0.8 (unitless) for 5 sec consecutively
Urea injection command is ≤ 0.05ml/sec for 100 sec. The timer to exit this condition is enabled in the
event of a Key Switch OR if the Operation cycle is completed.
AND
Number of decisions of Urea Doser Functional Response Monitor < 3counts OR the 5394.7-SE7927 is
active.
Filtered total fueling is ≤ 15 mg/stroke for 2 sec. Where filter time constant (tau = 2 sec).
| instantaneous Engine Out NOx concentration - moving average Engine Out NOx concentration | /
moving average Engine Out NOx concentration > 50 (ratio)

Malfunction Thresholds (all active):


EWMA filtered calculated DeNOx Efficiency < 25 %

Cummins Inc. Revision Date: March 30, 2017 525


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

400. 4339.7-SE10852: Aftertreatment 1 SCR Feedback Control Status -


Mechanical System Not Responding or Out of Adjustment
SCR inner control loop has used up all its adjustment allowed.

Monitor Operation:
DTC 4339.7-SE10852
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 120 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508

Cummins Inc. Revision Date: March 30, 2017 526


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895


3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3226.2-SE7613
3226.10-SE5989
3226.21-SE5978
3226.20-SE5976
4794.31-SE10102
4364.31-SE10910
3226.4-SE11104
3226.11-SE11496
Engine Protection is not active.
Aftertreatment State is in Base mode
All common enable condition for control loop used up is active (See RefCond103.79.)
SCR Inner loop used up enable conditions are true. (See RefCond104.79.)
NOT[Any of the DEF Doser related errors are active. (See RefCond507.1.)]
NOT[Any of the DEF Doser related errors are active. (See RefCond508.1.)]

Abort Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,

Cummins Inc. Revision Date: March 30, 2017 527


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,


412.2-SE3878
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
5031.10-SE5051
3228.2-SE5988
3226.4-SE5990
3226.4-SE5987
3226.2-SE7613
3226.10-SE5989
3226.21-SE5978
3226.20-SE5976
4794.31-SE10102
4364.31-SE10910
3226.4-SE11104
3226.11-SE11496
Aftreatment operation mode is not base mode
Engine Protection is active.
Any of the DEF Doser related errors are active. (See RefCond507.1.)
Any of the DEF Doser related errors are active. (See RefCond508.1.)

Pause Conditions (any active):


NOT[All common enable condition for control loop used up is active (See RefCond103.79.)].

Cummins Inc. Revision Date: March 30, 2017 528


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


Percent of (time SCR Inner Loop is used up / time all enable conditions are active) > 90% Where: SCR
Inner Loop is used up when: SCR conversion efficiency variation term settles down. (See
RefCond194.3.) AND (SCR Conversion Efficiency Relay feedback mode is commanding very high ANR.
(See RefCond88.5.) OR SCR Conversion Efficiency Relay feedback mode is commanding high dosing for
accelerated ammonia storage in SCR first brick (See RefCond89.14.)) AND { ((Target SCR Conversion
Efficiency - Final estimate SCR Conversion Efficiency) > switching threshold * 0.5scalar AND SCR
Conversion Efficiency Relay feedback mode is commanding very high ANR. (See RefCond88.5.)) OR
Actual SCR Conversion Efficiency ≤ 0% }
Where
Switching threshold =RefTable40.5

Cummins Inc. Revision Date: March 30, 2017 529


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

401. 4364.31-SE10910: Aftertreatment 1 SCR Conversion Efficiency -


Condition Exists
The system has detected a decrease of the NOx converting catalyst's conversion capability resulting in
tailpipe out NOx emissions exceeding the applicable threshold.

Monitor Operation:
DTC 4364.31-SE10910
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
4363.0-SE2889
4363.16-SE5295
4363.0-SE5293
4794.31-SE10102
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366, 3610.10-SE2983,
3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,

Cummins Inc. Revision Date: March 30, 2017 530


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-


SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
5394.7-SE7927
4331.16-SE12528
4331.18-SE12527
3226.2-SE7613
3228.2-SE6021
3226.21-SE5978
3226.20-SE5976
3226.4-SE11104
3226.11-SE11496
3227.20-SE12580
3227.21-SE12581
EGR Off Engine Protection is not active
80 g/s <= Mass flow rate <= 450 g/s.
-25 g/s2 <= Rate of change of |Filtered (tau = 2 sec) exhaust mass flow rate| <= 25 g/s2.
(Filtered (tau = 2 sec) exhaust mass flow rate) ≥ 90 g/s for 5 sec AND (Filtered (tau = 2 sec) exhaust
mass flow rate) > 80 g/s.
25 ppm < Input NOx concentration to SCR < 1,500 ppm.
Rate of change of (Filtered (tau = 2 sec) input NOx concentration to SCR) <= 20 ppm/s.
Deviation of input NOx concentration to SCR from its moving mean <= 50 (unitless) for RefTable52.3.
0.8 (unitless) <= (Filtered (tau = 0.2 sec) estimate of ammonia to NOx ratio) <= 1.5 (unitless).
Estimated ammonia to NOx ratio >= 0.8 (unitless) for 25 sec AND Estimated ammonia to NOx ratio >
0.8 (unitless).
Estimated ammonia to NOx ratio <= 1.2 (unitless) for 5 sec.
SCR out NOx <= 1,500 ppm.
Ambient air pressure >= 75 kPa(absolute).
Ambient air temperature ≥ -6.7 °C
OR
Urea Doser Functional Response Monitor updates the fault and Urea Doser Functional Response
Monitor System Error is not active (See RefCond237.6.)
OR
DEF injection rate > 0.1 ml/sec for 60 seconds.
250 degC <= SCR Bed temperature <= 450 degC.
RefTable200.1 ≤ Rate of change of (Filtered (tau = 50 sec) SCR bed temperature) < 1.2 degC/sec.
(Estimated ammonia to NOx ratio > 0.8 (unitless) AND SCR Bed temperature > 210 degC AND SCR Bed
temperature < 450 degC AND SCR Bed temperature <= 460 degC AND NOT [Engine control module off
time is greater thean a calibrated threshold. (See RefCond668.1.)] ) for 300 seconds.

Cummins Inc. Revision Date: March 30, 2017 531


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

[(Filtered (tau = 50 sec) rate of change of SCR bed temperature) < ( Estimated rate of change of SCR
bed temperature * 1 (unitless)) AND Actual rate of change of SCR bed temperature <= Estimated rate
of change of SCR bed temperature] for RefTable51.5. OR [Change in Bed temperature > 0 degC AND
(Filtered (tau = 50 sec) rate of change of SCR bed temperature) <= Estimated rate of change of SCR
bed temperature] for RefTable53.4.
Closed loop control of DEF dosing is allowed (See RefCond91.69.)
NOT [The fault due to Inhibit Switch timed regeneration is not active. (See RefCond122.2.)] OR
Decomposition Reactor Pipe (DRP) regeneration request is not active (See RefCond476.2.).
Key switch is turned ON.
Engine Out NOx status is valid.
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
0.05 g/sec <(Filtered (tau = 2 sec) engine out NOx mass flow rate) < 0.25 g/sec for 2 seconds
Rate of change of (Filtered (tau = 50 sec) SCR bed temperature) ≤ RefTable54.6.
NOT [When NH3 slip is detected, corrective action is taken. Commanded ANR is decreased by
temporarily stepping down the target SCR conversion efficiency. (See RefCond24.57.)] for 20 seconds
NOT [DEF intrusive dosing window is active (See RefCond478.38.)] for 0 sec
Dosing concentration correction is not active
Intrusive dosing is not active
NOT[Any of the DEF Doser related errors are active. (See RefCond507.1.)]
NOT[Any of the DEF Doser related errors are active. (See RefCond508.1.)]

Abort Conditions (any active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
4363.0-SE2889
4363.16-SE5295
4363.0-SE5293
4794.31-SE10102
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366, 3610.10-SE2983,
3610.20-SE3284, 3610.3-SE2882, 3610.4-SE2883
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-

Cummins Inc. Revision Date: March 30, 2017 532


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-


SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 3216.2-
SE5369, 3216.20-SE5365, 3216.21-SE5366, 3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-
SE5151, 3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-
SE6732, 3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857, 3610.10-SE2983, 3610.20-SE3284, 3610.3-
SE2882, 3610.4-SE2883, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876,
412.2-SE3877, 412.2-SE3878, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 4765.3-SE6729,
4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722, 5742.12-SE6724,
5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
5394.7-SE7927
4331.16-SE12528
4331.18-SE12527
3226.2-SE7613
3228.2-SE6021
3226.21-SE5978
3226.20-SE5976
3226.4-SE11104
3226.11-SE11496
3227.20-SE12580
3227.21-SE12581
The fault due to Inhibit Switch timed regeneration is not active. (See RefCond122.2.) AND Reactive
regen trigger is active. (See RefCond475.2.).
EGR Off Engine Protection is active
Key switch is turned OFF.
Dosing concentration correction is active
Intrusive dosing is active
Any of the DEF Doser related errors are active. (See RefCond507.1.)
Any of the DEF Doser related errors are active. (See RefCond508.1.)

Pause Conditions (any active):


Mass flow rate < 80 g/s OR Mass flow rate > 450 g/s.
Rate of change of (Filtered (tau = 2 sec) exhaust mass flow rate) < -25 g/s2 OR Rate of change of
(Filtered (tau = 2 sec) exhaust mass flow rate) > 25 g/s2.
(Filtered (tau = 2 sec) exhaust mass flow rate) < 90 g/s OR (Filtered (tau = 2 sec) exhaust mass flow
rate) <= 80 g/s for 5 sec.
Input NOx concentration to SCR is < 25 ppm OR Input NOx concentration to SCR is > 1,500 ppm.

Cummins Inc. Revision Date: March 30, 2017 533


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Rate of change of Filtered (tau = 2 sec) of input NOx concentration to SCR > 20 ppm/s.
Deviation from moving mean of input NOx concentration to SCR is > 50 (unitless).
Estimated (Filtered (tau = 0.2 sec) estimate of ammonia to NOx ratio) < 0.8 (unitless) OR Estimated
(Filtered (tau = 0.2 sec) estimate of ammonia to NOx ratio) > 1.5 (unitless).
Estimated ammonia to NOx ratio is < 0.8 (unitless) OR (Estimated ammonia to NOx ratio is <= 0.8
(unitless) for 6 sec.)
Estimated ammonia to NOx ratio is >= 1.5 (unitless) for 60 seconds.
SCR out NOx > 1,500 ppm.
Ambient air pressure < 75 kPa(absolute)
Ambient air temperature < -6.7 °C
SCR Bed temperature < 250 degC OR SCR Bed temperature > 450 degC.
RefTable201.1 > Rate of change of (Filtered (tau = 50 sec) SCR bed temperature) ≥ 1.2 degC/s.
Estimated ammonia to NOx ratio <= 0.8 (unitless) OR SCR Bed temperature <= 210 degC OR SCR Bed
temperature >= 450 degC OR SCR Bed temperature > 460 decC OR Engine control module off time is
greater thean a calibrated threshold. (See RefCond668.1.) .
[(Filtered (tau = 50 sec) rate of change of SCR bed temperature) ≥ ( Estimated rate of change of SCR
bed temperature * 1 (unitless))] AND [Change in SCR Bed temperature is <= 0 degC AND (Filtered (tau
= 50 sec) rate of change of SCR bed temperature) > Estimated rate of change of SCR bed
temperature].
NOT[Closed loop control of DEF dosing is allowed (See RefCond91.69.)]
When NH3 slip is detected, corrective action is taken. Commanded ANR is decreased by temporarily
stepping down the target SCR conversion efficiency. (See RefCond24.57.) AND Target catalyst
efficiency <= 75 %.
Not [Urea Doser Functional Response Monitor is ready to update the fault. (See RefCond127.12.)]
AND Dosing Not Allowed Flag indicating Dosing command is out of nominal range for Urea Doser
Functional Monitor (See RefCond84.19.) AND DEF injection rate <= 0.1 ml/sec AND (Operation cycle
is complete OR Key switch is turned ON).
Engine Out NOx status is not valid.
NOT[Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)].
0.05 g/sec ≥ (Filtered (tau = 2 sec) engine out NOx mass flow rate) ≥ 0.25 g/sec for 0.2 seconds.
When NH3 slip is detected, corrective action is taken. Commanded ANR is decreased by temporarily
stepping down the target SCR conversion efficiency. (See RefCond24.57.) for 5 seconds
Rate of change of (Filtered (tau = 50 sec) SCR bed temperature) > RefTable54.6 for 0.2 seconds.
(Filtered (tau = 0 sec) engine brake torque) is <= 100 N-m for 0.2 sec. Pause condition is removed
when (Filtered (tau = 0 sec) engine brake torque) ≥ 110 N-m for 1 sec
Engine is in Fast Idle Warmup mode.
Engine is in Power Take Off mode.
Engine is in a motoring condition
DEF intrusive dosing window is active (See RefCond478.38.)

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 534


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

EWMA filtered Amplified catalyst in-effeciency (ACIE) Where: ACIE is the SCR catalyst inefficiency
amplified using the ammonia to NOx ratio ≥ 25 (unitless).

Cummins Inc. Revision Date: March 30, 2017 535


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

402. 3217.20-SE12895: Aftertreatment Intake Oxygen Sensor - Data Not


Rational - Drifted High
The system has detected aftertreatment Inlet NOx sensor O2 reading within range but reading
inappropriately high.

Monitor Operation:
DTC 3217.20-SE12895
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 100 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Estimated O2 reading status is Valid.
Engine Out NOx status is Valid.
Intake O2 reading status is Valid.
Exhaust flow > 50 g/sec
Engine speed > 800 RPM
Virtual SCR Inlet O2% < 11.2 %
Virtual SCR Inlet O2% > 5 %
NOT {Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds}
NOT {Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds}
Engine is not in Hydrocarbon Desorption Mode
Engine is not in Water Desorption mode
Engine is not in Mobile Desoot Mode

Abort Conditions (any active):


3226.2-SE7613
3226.21-SE5978
3226.20-SE5976
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
3216.21-SE5366
3216.20-SE5365

Cummins Inc. Revision Date: March 30, 2017 536


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

3216.2-SE5369
102.20-SE3651
102.21-SE3652
105.2-SE4070
412.2-SE3876
412.2-SE3877
412.2-SE3878
27.2-SE3866
27.2-SE3867
DPF regeneration is active.
Key switch is turned OFF.
Ambient air temperature < -6.7 °C
Ambient air pressure < 75 kPa(absolute)
Engine is in Hydrocarbon Desorption Mode
Engine is in Water Desorption mode
Engine is in Mobile Desoot Mode

Pause Conditions (any active):


Intake O2 reading status is not valid.
Estimated O2 reading status is not valid.
Engine Out NOx status is not valid.
Not Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Not Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Exhaust flow ≤ 50 g/sec
Engine speed ≤ 800 RPM
Virtual SCR Inlet O2% ≥ 11.2 %
Virtual SCR Inlet O2% ≤ 5 %
Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds
Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds
0.2 sec have not elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Malfunction Thresholds (all active):


Average of error ((SCR In O2 - SCR Out O2) / Estimated Engine Out O2) over a 100 second period is
ever ≥ 0.4 % Diagnostic Tolerance = 0 %
Average of error ((SCR In O2 - Estimated Engine Out O2) / Estimated Engine Out O2) over a 100
second period is ever ≥ 0.24 % Diagnostic Tolerance = 0 %

Cummins Inc. Revision Date: March 30, 2017 537


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Average of error ((Estimated Engine Out O2 - SCR out O2) / Estimated Engine Out O2) over a 100
second period is NOT ever ≥ 0.75 % Diagnostic Tolerance = 0 %
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 538


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

403. 3217.21-SE12900: Aftertreatment Intake Oxygen Sensor - Data Not


Rational - Drifted Low
The system has detected aftertreatment Inlet NOx sensor O2 reading within range but reading
inappropriately low.

Monitor Operation:
DTC 3217.21-SE12900
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 100 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Estimated O2 reading status is Valid.
Engine Out NOx status is Valid.
Intake O2 reading status is Valid.
Exhaust flow > 50 g/sec
Engine speed > 800 RPM
Virtual SCR Inlet O2% < 11.2 %
Virtual SCR Inlet O2% > 5 %
NOT {Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds}
NOT {Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds}
Engine is not in Hydrocarbon Desorption Mode
Engine is not in Water Desorption mode
Engine is not in Mobile Desoot Mode

Abort Conditions (any active):


3226.2-SE7613
3226.21-SE5978
3226.20-SE5976
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
3216.21-SE5366
3216.2-SE5369

Cummins Inc. Revision Date: March 30, 2017 539


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

102.20-SE3651
102.21-SE3652
105.2-SE4070
412.2-SE3876
412.2-SE3877
27.2-SE3866
27.2-SE3867
DPF regeneration is active.
Key switch is turned OFF.
Ambient air temperature < -6.7 °C
Ambient air pressure < 75 kPa(absolute)
Engine is in Hydrocarbon Desorption Mode
Engine is in Water Desorption mode
Engine is in Mobile Desoot Mode

Pause Conditions (any active):


Intake O2 reading status is not valid.
Estimated O2 reading status is not valid.
Engine Out NOx status is not valid.
Not Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Not Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Exhaust flow ≤ 50 g/sec
Engine speed ≤ 800 RPM
Virtual SCR Inlet O2% ≥ 11.2 %
Virtual SCR Inlet O2% ≤ 5 %
Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds
Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds
0.2 sec have not elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Malfunction Thresholds (all active):


Average of error ((SCR out O2 - SCR In O2) / Estimated Engine Out O2) over a 100 second period is
ever ≥ 0.4 % Diagnostic Tolerance = 0 %
Average of error ((Estimated Engine Out O2 - SCR In O2) / Estimated Engine Out O2) over a 100
second period is ever ≥ 0.75 % Diagnostic Tolerance = 0 %
Average of error ((SCR out O2 - Estimated Engine Out O2) / Estimated Engine Out O2) over a 100
second period is NOT ever ≥ 0.22 % Diagnostic Tolerance = 0 %
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 540


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 541


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

404. 5862.2-SE2895: Aftertreatment 1 SCR Intermediate Gas


Temperature Sensor - Data Erratic, Intermittent, or Incorrect
Aftertreatment SCR catalyst gas temperature measurement is in-range but not rational.

Monitor Operation:
DTC 5862.2-SE2895
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4363.2-SE13180
(150 g/sec < Exhaust flow AND Elapsed time since last active regeneration < 1,200 sec AND Engine
running condition (See RefCond368.1.)) for 300 sec of persistent time
Engine Speed ≥ 200 RPM for 600 sec
(100 degC < SCR inlet/midbed temperature < 400 degC ) OR (100 degC < SCR outlet temperature <
400 degC)
300 seconds have elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Abort Conditions (any active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4363.2-SE13180
Regeneration is active or amount of time elapsed since last active regeneration is < 1,200 sec.

Pause Conditions (any active):


Exhaust flow < 150 g/sec OR NOT[Engine running condition (See RefCond368.1.)]
Engine Speed < 200 RPM

Cummins Inc. Revision Date: March 30, 2017 542


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

(SCR inlet/midbed temperature < 100 degC OR SCR inlet/midbed temperature > 400 degC ) AND (SCR
outlet temperature < 100 degC OR SCR outlet temperature > 400 degC)
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
SCR Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond61.4.)
SCR Out temperature sensor reading no value and not yet confirmed as faulty. (See RefCond420.1.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


(Average of (SCR inlet/midbed - SCR outlet) > 85 degC) OR (Average of (SCR inlet/midbed - SCR outlet)
< -70 degC)

Cummins Inc. Revision Date: March 30, 2017 543


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

405. 5862.14-SE7288: Aftertreatment 1 SCR Intermediate Gas


Temperature - Special Instructions
Aftertreatment SCR either Inlet or Outlet temperature sensor has been tampered with.

Monitor Operation:
DTC 5862.14-SE7288
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
Engine Speed > 400 RPM for 60 seconds
Ambient Air Pressure ≥ 75 kPa(absolute)
Ambient Air Temperature ≥ -6.7 °C
Exhaust flow has been ≥ 0 g/sec for 5 seconds within the current drive cycle.
Exhaust flow ≥ 0 g/sec

Abort Conditions (any active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
Engine Speed ≤ 1,200 RPM for 120 seconds.
Engine Fueling ≤ 55 mg/stroke for 120 seconds.
The Engine is in Fast Idle Warmup.

Pause Conditions (any active):


Engine Speed ≤ 1,200 RPM
Engine Fueling ≤ 55 mg/stroke
Diagnostic will immediately pause if either Pause Condition occurs. Once paused, diagnostic will
remain paused until both limits have been exceeded for 10 seconds.

Malfunction Thresholds (all active):


SCR Inlet/Midbed Temperature < 190 °C
OR
SCR Outlet temperature < 200 °C

Cummins Inc. Revision Date: March 30, 2017 544


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

406. 3227.20-SE12580: Aftertreatment Outlet Oxygen - Data Not


Rational - Drifted High
The system has detected aftertreatment outlet NOx sensor O2 reading within range but reading
inappropriately high.

Monitor Operation:
DTC 3227.20-SE12580
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 100 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Estimated O2 reading status is Data Valid.
Engine Out NOx status is Data Valid.
Intake O2 reading status is Data Valid.
Exhaust flow > 50 g/sec
Engine speed > 800 RPM
Virtual SCR Inlet O2% < 11.2 %
Virtual SCR Inlet O2% > 5 %
NOT {Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds}
NOT {Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds}
Engine is not in Hydrocarbon Desorption Mode
Engine is not in Water Desorption Mode
Engine is not in Mobile Desoot Mode

Abort Conditions (any active):


DPF regeneration is active.
Key switch is turned OFF.
Ambient air temperature < -6.7 °C
Ambient air pressure < 75 kPa(absolute)
Engine is in Hydrocarbon Desorption Mode
Engine is in Water Desorption Mode
Engine is in Mobile Desoot Mode

Cummins Inc. Revision Date: March 30, 2017 545


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Pause Conditions (any active):


Intake O2 reading status is not valid.
Estimated O2 reading status is not valid.
Engine Out NOx status is not valid.
Not Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Not Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Exhaust flow ≤ 50 g/sec
Engine speed ≤ 800 RPM
Virtual SCR Inlet O2% ≥ 11.2 %
Virtual SCR Inlet O2% ≤ 5 %
Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds
Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds
0.2 sec have not elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Malfunction Thresholds (all active):


Average of error ((SCR Out O2 - SCR In O2) / Estimated Engine Out O2) over a 100 second period is
ever ≥ 0.4 % Diagnostic Tolerance = 0 %
Average of error ((SCR Out O2 - Estimated Engine Out O2) / Estimated Engine Out O2) over a 100
second period is ever ≥ 0.22 % Diagnostic Tolerance = 0 %
Average of error ((SCR In O2 - Estimated Engine Out O2) / Estimated Engine Out O2) over a 100
second period is NOT ever ≥ 0.24 % Diagnostic Tolerance = 0 %
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 546


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

407. 3227.21-SE12581: Aftertreatment Outlet Oxygen - Data Not


Rational - Drifted Low
The system has detected aftertreatment outlet NOx sensor O2 reading within range but reading
inappropriately low.

Monitor Operation:
DTC 3227.21-SE12581
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 100 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Estimated O2 reading status is Data Valid.
Engine Out NOx status is Data Valid.
Intake O2 reading status is Data Valid.
Exhaust flow > 50 g/sec
Engine speed > 800 RPM
Virtual SCR Inlet O2% < 11.2 %
Virtual SCR Inlet O2% > 5 %
NOT {Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds}
NOT {Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds}
Engine is not in Hydrocarbon Desorption Mode
Engine is not in Water Desorption Mode
Engine is not in Mobile Desoot Mode

Abort Conditions (any active):


171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
DPF regeneration is active.
Key switch is turned OFF.
Ambient air temperature < -6.7 °C
Ambient air pressure < 75 kPa(absolute)
Engine is in Hydrocarbon Desorption Mode

Cummins Inc. Revision Date: March 30, 2017 547


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Engine is in Water Desorption Mode


Engine is in Mobile Desoot Mode

Pause Conditions (any active):


Intake O2 reading status is not valid.
Estimated O2 reading status is not valid.
Engine Out NOx status is not valid.
Not Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond86.9.)
Not Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the
sensor are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage
is within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Exhaust flow ≤ 50 g/sec
Engine speed ≤ 800 RPM
Virtual SCR Inlet O2% ≥ 11.2 %
Virtual SCR Inlet O2% ≤ 5 %
Absolute value of rate of change of Engine speed is > 40 RPM/s for 0.8 seconds
Absolute value of rate of change of Engine exhaust flow is > 20 g/sec2 for 0.2 seconds
0.2 sec have not elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Malfunction Thresholds (all active):


Average of error ((SCR In O2 - SCR Out O2) / Estimated Engine Out O2) over a 100 second period is
ever ≥ 0.6 % Diagnostic Tolerance = 0 %
Average of error ((Estimated Engine Out O2 - SCR Out O2) / Estimated Engine Out O2) over a 100
second period is ever ≥ 0.75 % Diagnostic Tolerance = 0 %
Average of error ((Estimated Engine Out O2 - SCR In O2) / Estimated Engine Out O2) over a 100
second period is NOT ever ≥ 0.75 % Diagnostic Tolerance = 0 %
(Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 548


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

408. 4363.2-SE3785: Aftertreatment 1 SCR Outlet Temperature Sensor -


Data Erratic, Intermittent, or Incorrect
Aftertreatment SCR outlet gas temperature is in-range but not rational.

Monitor Operation:
DTC 4363.2-SE3785
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4363.2-SE13180
(150 g/sec < Exhaust flow AND Elapsed time since last active regeneration < 1,200 sec AND Engine
running condition (See RefCond368.1.)) for 300 sec of persistent time
Engine Speed ≥ 200 RPM for 600 sec
(100 degC < SCR inlet/midbed temperature < 400 degC ) OR (100 degC < SCR outlet temperature <
400 degC)
300 seconds have elapsed since OBD Arbitrator allows Quantity and Timing Diagnostics (See
RefCond63.7.) was active

Abort Conditions (any active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
5742.9-SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
3242.2-SE13174, 3242.2-SE13177, 3246.2-SE13175, 3246.21-SE13178, 4363.2-SE13180
Regeneration is active or 1,200 sec amount of time has not elapsed since last active regeneration.

Pause Conditions (any active):


Exhaust flow < 150 g/sec OR NOT[Engine running condition (See RefCond368.1.)]
Engine Speed < 200 RPM

Cummins Inc. Revision Date: March 30, 2017 549


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

(SCR inlet/midbed temperature < 100 degC OR SCR inlet/midbed temperature > 400 degC ) AND (SCR
outlet temperature < 100 degC OR SCR outlet temperature > 400 degC)
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
SCR Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond61.4.)
SCR Out temperature sensor reading no value and not yet confirmed as faulty. (See RefCond420.1.)
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond65.2.)
DOC Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond384.2.)
DPF Outlet temperature sensor have no value and not yet confirmed as faulty. (See RefCond386.2.)

Malfunction Thresholds (all active):


(Average of (SCR inlet/midbed - SCR outlet) > 85 degC) OR (Average of (SCR inlet/midbed - SCR
outlet)< -70 degC)
-70 degC < average of (DPF outlet - SCR inlet/midbed) < 85 degC

Cummins Inc. Revision Date: March 30, 2017 550


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

409. 4363.2-SE13180: Aftertreatment 1 SCR Outlet Temperature Sensor


- Data Erratic, Intermittent, or Incorrect
Exhaust gas temperature sensor at SCR Outlet is in-range high.

Monitor Operation:
DTC 4363.2-SE13180
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
Engine speed ≤ 600 RPM
NOT {SCR Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond418.2.)}
Module-off time > 28,800 sec
Module-off time status is valid
Key switch is ON and diagnostic has not made a decision in current key cycle.

Abort Conditions (any active):


4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765
Engine speed > 600 RPM for 10 sec.
SCR Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond418.2.)

Pause Conditions (any active):


SCR Outlet Temperature sensor reading is suspected and not yet confirmed as faulty. (See
RefCond61.4.)
SCR Out temperature sensor reading no value and not yet confirmed as faulty. (See RefCond420.1.)
Module-off time ≤ 28,800 sec
Module-off time status is not valid

Malfunction Thresholds (all active):


Average SCR Outlet temperature over 2 seconds ≥ 70 °C

Cummins Inc. Revision Date: March 30, 2017 551


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

410. 5031.10-SE5982: Aftertreatment 1 Outlet NOx Sensor Heater -


Abnormal Rate of Change
Aftertreatment outlet NOx sensor heater malfunction.

Monitor Operation:
DTC 5031.10-SE5982
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
Time after the sensor has reached it working temperature and has entered automatic mode > 30 sec
Exhaust gas velocity < 60 m/sec
SCR outlet temperature < 800 °C
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.)
Nox sensor battery supply voltage is within the desired range of [10.8, 16.5] V for more than 0.2
seconds.

Abort Conditions (any active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
Exhaust gas velocity ≥ 60 m/sec
SCR outlet temperature ≥ 800 °C
Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)
Nox sensor battery supply voltage is outside the desired range of [10.8, 16.5] V.

Malfunction Thresholds (all active):


(The percentage of time spent with the sensor in a heating mode other than automatic mode > 10 %
of the time that the monitor takes to make a decision) OR (Number of transitions from automatic
mode to other states > 5) counts

Cummins Inc. Revision Date: March 30, 2017 552


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

411. 4363.16-SE5295: Aftertreatment 1 SCR Outlet Temperature - Data


Valid But Above Normal Operating Range - Moderately Severe
Level
Aftertreatment SCR outlet gas temperature is continuously above a high threshold for a calibrated
period of time while active regeneration of the DPF is not occurring.

Monitor Operation:
DTC 4363.16-SE5295
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
(Rate of active/intrusive injection of hydrocarbons in exhaust < 0.2 g/sec AND Engine running
condition (See RefCond368.1.)) for 540 sec of persistent time.

Pause Conditions (any active):


SCR Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond418.2.)
Rate of active/intrusive injection of hydrocarbons in exhaust ≥ 0.2 g/sec.
NOT [Engine running condition (See RefCond368.1.)].

Malfunction Thresholds (all active):


SCR outlet temperature > 650 °C

Cummins Inc. Revision Date: March 30, 2017 553


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

412. 4363.0-SE5293: Aftertreatment 1 SCR Outlet Temperature - Data


Valid But Above Normal Operating Range - Most Severe Level
Aftertreatment SCR outlet gas temperature continuously above a severe, high threshold for a calibrated
period of time.

Monitor Operation:
DTC 4363.0-SE5293
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 60 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895

Abort Conditions (any active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895

Malfunction Thresholds (all active):


SCR outlet temperature > 700 °C

Cummins Inc. Revision Date: March 30, 2017 554


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

413. 3509.3-SE243: Sensor Supply 1 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 1 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3509.3-SE243
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 1 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 555


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

414. 3509.4-SE225: Sensor Supply 1 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 1 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3509.4-SE225
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 1 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 556


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

415. 3510.3-SE119: Sensor Supply 2 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 2 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3510.3-SE119
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 2 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 557


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

416. 3510.4-SE101: Sensor Supply 2 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 2 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3510.4-SE101
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 2 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 558


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

417. 3511.3-SE814: Sensor Supply 3 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 3 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3511.3-SE814
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 3 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 559


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

418. 3511.4-SE816: Sensor Supply 3 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 3 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3511.4-SE816
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 3 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 560


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

419. 3512.3-SE817: Sensor Supply 4 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 4 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3512.3-SE817
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 4 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 561


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

420. 3512.4-SE815: Sensor Supply 4 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 4 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3512.4-SE815
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 4 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 562


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

421. 3513.3-SE1893: Sensor Supply 5 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 5 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3513.3-SE1893
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 5 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 563


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

422. 3513.4-SE1894: Sensor Supply 5 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 5 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3513.4-SE1894
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 5 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 564


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

423. 3514.3-SE2030: Sensor Supply 6 Circuit - Voltage Above Normal or


Shorted to High Source
Sensor Supply 6 voltage reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3514.3-SE2030
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 6 Voltage > 5.356 V

Cummins Inc. Revision Date: March 30, 2017 565


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

424. 3514.4-SE2031: Sensor Supply 6 Circuit - Voltage Below Normal or


Shorted to Low Source
Sensor Supply 6 voltage reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 3514.4-SE2031
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.4 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Sensor Supply 6 Voltage < 4.644 V

Cummins Inc. Revision Date: March 30, 2017 566


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

425. 521.2-SE8109: Brake Pedal Position - Data Erratic, Intermittent, or


Incorrect
Brake Switch 1 and Brake Switch 2 disagree.

Monitor Operation:
DTC 521.2-SE8109
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 (counts)
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Key Switch is ON.

Abort Conditions (any active):


Key Switch is OFF.

Malfunction Thresholds (all active):


(Brake Switch 1 is On AND Brake Switch 2 is Off) OR (Brake Switch 1 is Off AND Brake Switch 2 is On)
FOR 4 (seconds)

Cummins Inc. Revision Date: March 30, 2017 567


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

426. 6304.31-SE7827: Brake Switch and Accelerator Pedal Position


Incompatible - Condition Exists
Accelerator Pedal and Service Brake Pedal are both depressed

Monitor Operation:
DTC 6304.31-SE7827
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration RefTable119.1 sec
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Vehicle Speed > 7.456 mph

Abort Conditions (any active):


521.2-SE8109

Malfunction Thresholds (all active):


Idle Validation Switch indicates Not Idle and Service Brake Switch is Active

Cummins Inc. Revision Date: March 30, 2017 568


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

427. 5246.0-SE5496: Aftertreatment SCR Operator Inducement - Data


Valid But Above Normal Operating Range - Most Severe Level
Active Severe Driver Inducement (see AECD Document section 7-1 and Appendix VI)

Monitor Operation:
DTC 5246.0-SE5496
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration See AECD Document section 7-1 and Appendix VI
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


Key Switch is OFF
OR
Idle Shutdown has shutdown engine
OR
Amount of time at Idle > 3,600 seconds
OR
Fuel Level has increased > 15 percent since last Key On, at a rate less than 15 percent/second

Malfunction Thresholds (all active):


One or more conditions exist requiring Severe Driver Inducement (see AECD Document section 7-1
and Appendix VI)

Cummins Inc. Revision Date: March 30, 2017 569


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

428. 1675.31-SE5497: Engine Starter Mode Overcrank Protection -


Condition Exists
The error is set when the starter is locked out due to engine cranking longer than allowed time.

Monitor Operation:
DTC 1675.31-SE5497
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Engine is cranking.

Cummins Inc. Revision Date: March 30, 2017 570


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

429. 677.4-SE323: Engine Starter Motor Relay Circuit - Voltage Below


Normal or Shorted to Low Source
Starter Lockout Driver voltage is below voltage limit.

Monitor Operation:
DTC 677.4-SE323
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Starter Lockout Driver ECM pin and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 571


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

430. 677.3-SE324: Engine Starter Motor Relay Circuit - Voltage Above


Normal or Shorted to High Source
Starter Lockout Driver voltage is above voltage limit.

Monitor Operation:
DTC 677.3-SE324
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The resistance between the Starter Lockout Driver and ground > 500,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 572


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

431. 3060.18-SE12227: Engine Cooling System Monitor - Data Valid But


Below Normal Operating Range - Moderately Severe Level
Predicted Coolant Temperature is greater than Coolant Temperature.

Monitor Operation:
DTC 3060.18-SE12227
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 600 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE4070, 105.3-SE487, 105.4-SE488,
110.3-SE75, 110.4-SE76, 171.2-SE3799, 171.3-SE3802, 171.4-SE3803, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878, 412.3-SE496, 412.4-SE495
Engine Speed > 300 RPM
At Engine Start, Coolant Temperature < 51.594 °C
If Block heater is detected (See RefCond421.1.) then time after engine has started ≥ 360 sec ELSE time
after engine has started ≥ 60 sec
Ambient Air Temperature ≥ -6.664 °C

Abort Conditions (any active):


102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE4070, 105.3-SE487, 105.4-SE488,
110.3-SE75, 110.4-SE76, 171.2-SE3799, 171.3-SE3802, 171.4-SE3803, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878, 412.3-SE496, 412.4-SE495
Engine Speed ≤ 300 RPM
Ambient Air Temperature < -6.664 °C

Pause Conditions (any active):


Engine Speed < 750 RPM
Engine Speed > 1,500 RPM
EGR Flow < 0.102 kg/min
EGR Flow > 4 kg/min
Torque Fuel > 100 mg/stroke
Torque Fuel < 10 mg/stroke
Coolant Temperature ≥ 71.109 °C

Malfunction Thresholds (all active):


Predicted Coolant Temperature > Coolant Temperature

Cummins Inc. Revision Date: March 30, 2017 573


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 574


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

432. 237.13-SE7946: Vehicle Identification Number - Out of Calibration


The error is set when an unprogrammed VIN has been detected.

Monitor Operation:
DTC 237.13-SE7946
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 0.02 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


Time elapsed after power up ≥ 60 sec

Malfunction Thresholds (all active):


All the values in the VIN are ASCII 0 (HEX 30).

Cummins Inc. Revision Date: March 30, 2017 575


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

433. 630.12-SE2909: Engine Control Module Calibration Memory


Software - Bad Intelligent Device or Component
Two mutually exclusive features are enabled.

Monitor Operation:
DTC 630.12-SE2909
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Two mutually exclusive features that share the same I/O are enabled AND the I/O is NOT multiplexed.

Cummins Inc. Revision Date: March 30, 2017 576


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

434. 103.7-SE12073: Engine Turbocharger 1 Speed - Mechanical System


Not Responding or Out of Adjustment
Turbo shaft is seized. Turbo Speed sensor value is zero when engine is running.

Monitor Operation:
DTC 103.7-SE12073
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Tmax ≤ 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


103.16-SE3641, 103.18-SE3642
Engine is not in run state.
Engine Speed ≤ 1,000 RPM
Torque Fueling is ≤ 40mg/stroke

Malfunction Thresholds (all active):


Average of (1.5 kRPM - Turbo Speed) over a 30 second period is ever ≥ 1.45 kRPM Diagnostic
Tolerance = 0 kRPM (Please refer to the CUSUM Supplement in Section C for further details.)

Cummins Inc. Revision Date: March 30, 2017 577


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

435. 103.16-SE3641: Turbocharger 1 Speed - Data Valid But Above


Normal Operating Range - Moderately Severe Level
Turbo speed sensor reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 103.16-SE3641
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 5 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Raw Turbo Speed value > 2,500 Hz (150 KRPM)

Cummins Inc. Revision Date: March 30, 2017 578


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

436. 103.18-SE3642: Turbocharger 1 Speed - Data Valid But Below


Normal Operating Range - Moderately Severe Level
Turbo speed sensor reading less than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 103.18-SE3642
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Pause Conditions (any active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
Ratio of Charge Pressure and Ambient Air Pressure < 1.2
Filtered Engine Speed < 1,200 RPM

Malfunction Thresholds (all active):


Raw Turbo Speed < 50 Hz (3 KRPM), for 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 579


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

437. 103.15-SE2023: Turbocharger 1 Speed - Data Valid But Above


Normal Operating Range - Least Severe Level
Turbo Speed above normal engine operating range

Monitor Operation:
DTC 103.15-SE2023
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria Non-OBD

Abort Conditions (any active):


102.20-SE3651, 102.21-SE3652, 103.16-SE3641, 103.18-SE3642

Malfunction Thresholds (all active):


Turbo Charger Speed ≥ 139 KRPM

Cummins Inc. Revision Date: March 30, 2017 580


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

438. 3361.3-SE7289: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit -


Voltage Above Normal or Shorted to High Source
DEF Supply Module power driver control line is shorted to high voltage or open circuit.

Monitor Operation:
DTC 3361.3-SE7289
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The DEF Supply Module power command is OFF.
5 sec has not expired since Key Switch ON.

Abort Conditions (any active):


The DEF Supply Module power command is ON.
5 sec has expired since key switch ON.

Malfunction Thresholds (all active):


The resistance between the DEF Supply Module power driver line and ground > 500,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 581


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

439. 3361.4-SE7290: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit -


Voltage Below Normal or Shorted to Low Source
DEF Supply Module power driver control line is shorted to ground.

Monitor Operation:
DTC 3361.4-SE7290
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


The DEF Supply Module power command is ON.
DEF pump motor command is ON.

Abort Conditions (any active):


The DEF Supply Module power command is OFF.
DEF pump motor command is OFF.

Malfunction Thresholds (all active):


The resistance between the DEF Supply Module power driver line and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 582


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

440. 4375.3-SE6095: Aftertreatment 1 Diesel Exhaust Fluid Pump


Command Circuit - Voltage Above Normal or Shorted to High
Source
DEF pump motor driver control line is shorted to high voltage.

Monitor Operation:
DTC 4375.3-SE6095
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


The DEF pump motor command is ON.

Pause Conditions (any active):

Malfunction Thresholds (all active):


The resistance between the DEF pump motor driver line and Vehicle Battery < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 583


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

441. 4375.4-SE6094: Aftertreatment 1 Diesel Exhaust Fluid Pump


Command Circuit - Voltage Below Normal or Shorted to Low
Source
DEF pump motor driver control line is shorted to ground or open circuit.

Monitor Operation:
DTC 4375.4-SE6094
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3361.3-SE7289, 3361.4-SE7290, 520953.4-SE11755
DEF Supply Module power channel is ON.
The resistance between the DEF Supply Module power driver line and ground ≤ 500,000 Ohms
The resistance between the DEF Supply Module power driver line and ground ≥ 0.2 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery ≥ 0.2 Ohms
DEF Supply Module power feedback voltage > 5 V

Abort Conditions (any active):


3361.3-SE7289, 3361.4-SE7290, 520953.4-SE11755

Pause Conditions (any active):


DEF Supply Module power channel is OFF.
The resistance between the DEF Supply Module power driver line and ground > 500,000 Ohms
The resistance between the DEF Supply Module power driver line and ground < 0.2 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery < 0.2 Ohms
DEF Supply Module power feedback voltage ≤ 5 V

Malfunction Thresholds (all active):


The resistance between the DEF pump motor driver line and Vehicle Battery > 1,000,000 Ohms

Cummins Inc. Revision Date: March 30, 2017 584


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

442. 4334.16-SE7004: Aftertreatment 1 Diesel Exhaust Fluid Pressure -


Data Valid But Above Normal Operating Range - Moderately
Severe Level
Checks whether the DEF pump motor is pumping too much DEF and over-pressurizing the doser, despite
the closed loop control.

Monitor Operation:
DTC 4334.16-SE7004
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094
DEF Supply Module is not in OFF state.
DEF Supply Module is not in STANDBY state.
DEF Supply Module is not in INIT state.
Not [Ambient air temperature is cold (See RefCond412.1.)]

Abort Conditions (any active):


4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094
DEF Supply Module is in OFF state.
DEF Supply Module is in STANDBY state.
DEF Supply Module is in INIT state.

Pause Conditions (any active):


Ambient air temperature is cold (See RefCond412.1.)

Malfunction Thresholds (all active):


DEF Doser Module (DM) pressure > 1,100 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 585


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

443. 4334.18-SE7005: Aftertreatment 1 Diesel Exhaust Fluid Pressure -


Data Valid But Below Normal Operating Range - Moderately Severe
Level
Checks whether the DEF pump motor is unable to pump sufficient DEF to maintain the correct DEF
pressure in dosing system, despite the closed loop control.

Monitor Operation:
DTC 4334.18-SE7005
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 200 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094
(
The DEF Supply Module (SM) has completed pump pressure control and is ready to dose. (See
RefCond87.5.)
OR
The DEF recirculation is active due to hot shutdown. (See RefCond413.3.)
)
Not [Ambient air temperature is cold (See RefCond412.1.)]

Abort Conditions (any active):


4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094
Not [ The DEF Supply Module (SM) has completed pump pressure control and is ready to dose. (See
RefCond87.5.) OR The DEF recirculation is active due to hot shutdown. (See RefCond413.3.) ]

Pause Conditions (any active):


Ambient air temperature is cold (See RefCond412.1.)

Malfunction Thresholds (all active):


DEF Doser Module (DM) pressure < 700 kPa(gauge)

Cummins Inc. Revision Date: March 30, 2017 586


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

444. 3364.3-SE8691: Aftertreatment Diesel Exhaust Fluid Quality Sensor


Circuit - Voltage Above Normal or Shorted to High Source
The Urea Quality Sensor (UQS) concentration sensing element has been shorted to a high voltage source

Monitor Operation:
DTC 3364.3-SE8691
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond136.4.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond137.3.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: (UQS Concentration detection element voltage shorted out of range high. (See
RefCond42.2.) is not satisfied AND Unknown failure of the UQS concentration detection element, or
UQS Concentration detection element voltage shorted out of range low. (See RefCond30.2.) is
satisfied).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: UQS Concentration detection element voltage shorted out of range high. (See
RefCond43.2.) is not satisfied
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: (UQS Concentration detection element voltage shorted out of range high. (See
RefCond372.1.) is not satisfied AND Unknown failure of the UQS concentration detection element, or
UQS Concentration detection element voltage shorted out of range low. (See RefCond458.1.) is
satisfied).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: UQS Concentration detection element voltage shorted out of range high. (See
RefCond42.2.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond42.2.)) is not active AND (Unknown
failure of the UQS concentration detection element, or UQS Concentration detection element voltage
shorted out of range low. (See RefCond30.2.)) is not active).

Cummins Inc. Revision Date: March 30, 2017 587


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: UQS Concentration detection element voltage shorted out of range high. (See
RefCond43.2.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond43.2.)) is not active AND (UQS
Concentration detection element voltage shorted out of range low. (See RefCond44.2.)) is not active
AND (UQS sensor internal temperature is above the maximum operating range (See RefCond135.2.))
is not active).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: UQS Concentration detection element voltage shorted out of range high. (See
RefCond372.1.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond372.1.)) is not active AND (UQS
Concentration detection element voltage shorted out of range low. (See RefCond371.1.)) is not active
AND (UQS sensor internal temperature is above the maximum operating range (See RefCond457.1.))
is not active).

Cummins Inc. Revision Date: March 30, 2017 588


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

445. 3364.4-SE8692: Aftertreatment Diesel Exhaust Fluid Quality Sensor


Circuit - Voltage Below Normal or Shorted to Low Source
The Urea Quality Sensor (UQS) concentration sensing element has been shorted to a high voltage source

Monitor Operation:
DTC 3364.4-SE8692
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond426.2.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond427.2.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: UQS Concentration detection element voltage shorted out of range low. (See
RefCond44.2.) is cumulatively satisfied for more than 5 seconds, since the last time that ((UQS
Concentration detection element voltage shorted out of range high. (See RefCond43.2.)) is not active
AND(UQS Concentration detection element voltage shorted out of range low. (See RefCond44.2.)) is
not active AND (UQS sensor internal temperature is above the maximum operating range (See
RefCond135.2.)) is not active).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: UQS Concentration detection element voltage shorted out of range low. (See
RefCond371.1.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond372.1.)) is not active AND(UQS
Concentration detection element voltage shorted out of range low. (See RefCond371.1.)) is not active
AND (UQS sensor internal temperature is above the maximum operating range (See RefCond457.1.))
is not active).

Cummins Inc. Revision Date: March 30, 2017 589


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

446. 3364.2-SE8693: Aftertreatment Diesel Exhaust Fluid Quality - Data


Erratic, Intermittent, or Incorrect
The Urea Quality Sensor (UQS) is in an internal over-temperature condition

Monitor Operation:
DTC 3364.2-SE8693
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond428.2.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond429.2.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: UQS sensor internal temperature is above the maximum operating range (See
RefCond135.2.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond43.2.)) is not active AND (UQS
Concentration detection element voltage shorted out of range low. (See RefCond44.2.)) is not active
AND (UQS sensor internal temperature is above the maximum operating range (See RefCond135.2.))
is not active).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: UQS sensor internal temperature is above the maximum operating range (See
RefCond457.1.) is cumulatively satisfied for > 5 seconds, since the last time that ((UQS Concentration
detection element voltage shorted out of range high. (See RefCond372.1.)) is not active AND (UQS
Concentration detection element voltage shorted out of range low. (See RefCond371.1.)) is not active
AND (UQS sensor internal temperature is above the maximum operating range (See RefCond457.1.))
is not active).

Cummins Inc. Revision Date: March 30, 2017 590


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

447. 3521.18-SE13411: Aftertreatment 1 Diesel Exhaust Fluid Property -


Data Valid But Below Normal Operating Range - Moderately Severe
Level
The Urea Quality Sensor (UQS) has measured the concentration of DEF in the tank to be below the
minimum concentration threshold or DEF concentration status is unknown.

Monitor Operation:
DTC 3521.18-SE13411
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond317.28.)

Abort Conditions (any active):


The disable conditions for the diagnostic are specified as follows (See RefCond318.32.)

Pause Conditions (any active):


NOT [The enable conditions for the diagnostic are specified as follows (See RefCond317.28.)]
AND
NOT [The disable conditions for the diagnostic are specified as follows (See RefCond318.32.)]

Malfunction Thresholds (all active):


(The DEF concentration ≤ 26 % OR Urea concentration Measurement message status is Unknown) for
a percentage of time > 90 % within a monitoring time window. Where: The monitoring time window
is 300 seconds.

Cummins Inc. Revision Date: March 30, 2017 591


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

448. 3364.11-SE6996: Aftertreatment Diesel Exhaust Fluid Quality -


Root Cause Not Known
The Urea Quality Sensor (UQS) concentration sensing element has a 'Root Cause not Known' error.

Monitor Operation:
DTC 3364.11-SE6996
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond73.4.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond72.4.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: (Unknown failure of the UQS concentration detection element, or UQS Concentration
detection element voltage shorted out of range low. (See RefCond30.2.) is not satisfied AND UQS
Concentration detection element voltage shorted out of range high. (See RefCond42.2.) is satisfied).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: (Unknown failure of the UQS concentration detection element, or UQS Concentration
detection element voltage shorted out of range low. (See RefCond458.1.) is not satisfied AND UQS
Concentration detection element voltage shorted out of range high. (See RefCond372.1.) is satisfied).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: Unknown failure of the UQS concentration detection element, or UQS Concentration
detection element voltage shorted out of range low. (See RefCond30.2.) is cumulatively satisfied for >
5 seconds, since the last time that (UQS Concentration detection element voltage shorted out of
range high. (See RefCond42.2.) is not satisfied AND (Unknown failure of the UQS concentration
detection element, or UQS Concentration detection element voltage shorted out of range low. (See
RefCond30.2.)) is not satisfied).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: Unknown failure of the UQS concentration detection element, or UQS Concentration
detection element voltage shorted out of range low. (See RefCond458.1.) is cumulatively satisfied for
> 5 seconds, since the last time that (UQS Concentration detection element voltage shorted out of
range high. (See RefCond372.1.) is not satisfied AND (Unknown failure of the UQS concentration

Cummins Inc. Revision Date: March 30, 2017 592


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

detection element, or UQS Concentration detection element voltage shorted out of range low. (See
RefCond458.1.)) is not satisfied).

Cummins Inc. Revision Date: March 30, 2017 593


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

449. 3364.18-SE7282: Aftertreatment Diesel Exhaust Fluid Quality -


Data Valid But Below Normal Operating Range - Moderately Severe
Level
The Urea Quality Sensor (UQS) has measured the concentration of DEF in the tank to be below the
minimum concentration threshold.

Monitor Operation:
DTC 3364.18-SE7282
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then The enable
conditions for the low concentration diagnostic are specified as follows (See RefCond109.53.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond107.49.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the pause conditions
for the diagnostic are specified as follows (See RefCond108.37.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.): The DEF concentration ≤
22.5 % for a percentage of time greater than90 % within a monitoring time window. The monitoring
time window is 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C, and 300
seconds, otherwise.

Cummins Inc. Revision Date: March 30, 2017 594


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

450. 3521.16-SE13409: Aftertreatment 1 Diesel Exhaust Fluid Property -


Data Valid But Above Normal Operating Range - Moderately
Severe Level
The Urea Quality Sensor (UQS) has measured the concentration of DEF in the tank to be above the
maximum concentration threshold.

Monitor Operation:
DTC 3521.16-SE13409
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond322.28.)

Abort Conditions (any active):


The disable conditions for the diagnostic are specified as follows (See RefCond321.28.)

Pause Conditions (any active):


NOT[The enable conditions for the diagnostic are specified as follows (See RefCond322.28.)]
AND
NOT[The disable conditions for the diagnostic are specified as follows (See RefCond321.28.)]

Malfunction Thresholds (all active):


The DEF concentration ≥ 49.4% for a percentage of time > 90 % for a monitoring time window. Where
: The monitoring time window is 300 seconds.

Cummins Inc. Revision Date: March 30, 2017 595


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

451. 3521.31-SE13410: Aftertreatment 1 Diesel Exhaust Fluid Property -


Condition Exists
The Urea Quality Sensor (UQS) has been unable to generate a concentration estimate for longer than
the maximum wait time threshold, due to unsuitable measurement conditions.

Monitor Operation:
DTC 3521.31-SE13410
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 seconds if the initial DEF Tank Temperature
at keyon > 10 °C else 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond320.33.)

Abort Conditions (any active):


The disable conditions for the diagnostic are specified as follows (See RefCond319.27.)

Pause Conditions (any active):


NOT[The enable conditions for the diagnostic are specified as follows (See RefCond320.33.)]
AND
NOT[The disable conditions for the diagnostic are specified as follows (See RefCond319.27.)]

Malfunction Thresholds (all active):


When fluid type is DEF(32.5% of urea solution) AND No Failure mode is determined by the datalinked
UQS sensor AND The status of in-tank mounted measurement of DEF concentration quality is data
error no value. (See RefCond376.1.).

Cummins Inc. Revision Date: March 30, 2017 596


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

452. 3364.10-SE7286: Aftertreatment Diesel Exhaust Fluid Quality -


Abnormal Rate of Change
The Urea Quality Sensor (UQS) has been unable to generate a concentration estimate for longer than
the maximum wait time threshold, due to unsuitable measurement conditions.

Monitor Operation:
DTC 3364.10-SE7286
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond111.60.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond110.56.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the pause conditions
for the diagnostic are specified as follows (See RefCond113.57.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: (The Urea Quality Sensor (UQS) smart device controller is in the process of initializing
OR the DEF fluid is frozen or not present) for longer than a validation time and the status of in-tank
mounted measurement of DEF concentration quality is data error no value. The validation time is
equal to 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C, and the validation time
is equal to 300 seconds otherwise and The status of in-tank mounted measurement of DEF
concentration quality is data error no value. (See RefCond376.1.)
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: (The Urea Quality Sensor (UQS) smart device controller is unable to detect the
fluid type and concentration due to unsuitable operating conditions) for longer than a validation time
and the status of in-tank mounted measurement of DEF concentration quality is data error no value.
The validation time is equal to 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C,
and the validation time is equal to 300 seconds otherwise and The status of in-tank mounted
measurement of DEF concentration quality is data error no value. (See RefCond376.1.)

Cummins Inc. Revision Date: March 30, 2017 597


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

453. 3515.10-SE7285: Aftertreatment 1 Diesel Exhaust Fluid


Temperature 2 - Abnormal Rate of Change
The Urea Quality Sensor (UQS) signal is not rational at keyon.

Monitor Operation:
DTC 3515.10-SE7285
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond315.18.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond316.24.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.): (( |The first valid UQS
temperature after keyon when the DEF tank heater is inactive – the first valid charge temperature
after keyon when the DEF tank heater is inactive | > 40 °C) AND ( |The first valid UQS temperature
after keyon when the DEF tank heater is inactive - The first valid coolant temperature after keyon
when the DEF tank heater is inactive | > 40 °C)) Where: Tank heater activity is disclosed in AECD 13-3.

Cummins Inc. Revision Date: March 30, 2017 598


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

454. 3515.3-SE6981: Aftertreatment 1 Diesel Exhaust Fluid


Temperature 2 Sensor Circuit - Voltage Above Normal or Shorted
to High Source
The Urea Quality Sensor (UQS) temperature sensing element has been shorted to a high voltage source

Monitor Operation:
DTC 3515.3-SE6981
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond34.4.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond32.3.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: (Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.
(See RefCond29.2.) is not satisfied) AND (Unknown failure of the UQS concentration detection
element, or UQS Concentration detection element voltage shorted out of range low. (See
RefCond30.2.) is satisfied OR Urea Quality Sensor (UQS) temperature sensing element shorted to a
low source. (See RefCond33.2.) is satisfied)
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: (Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.
(See RefCond37.2.) is not satisfied) OR Urea Quality Sensor (UQS) temperature sensor element
shorted to a low source. (See RefCond36.2.) is satisfied
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: (Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.
(See RefCond370.1.) is not satisfied) AND (Unknown failure of the UQS concentration detection
element, or UQS Concentration detection element voltage shorted out of range low. (See
RefCond458.1.) is satisfied OR Urea Quality Sensor (UQS) temperature sensor element shorted to a
low source. (See RefCond374.1.) is satisfied)

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.

Cummins Inc. Revision Date: March 30, 2017 599


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

(See RefCond29.2.) is cumulatively satisfied for longer than 5 seconds, since the last time that (Urea
Quality Sensor (UQS) temperature sensor element shorted to a high source. (See RefCond29.2.) is not
satisfied AND Urea Quality Sensor (UQS) temperature sensing element shorted to a low source. (See
RefCond33.2.) is not satisfied).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.
(See RefCond37.2.) is cumulatively satisfied for longer than 5 seconds, since the last time that (Urea
Quality Sensor (UQS) temperature sensor element shorted to a high source. (See RefCond37.2.) is not
satisfied AND Urea Quality Sensor (UQS) temperature sensor element shorted to a low source. (See
RefCond36.2.) is not satisfied).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: Urea Quality Sensor (UQS) temperature sensor element shorted to a high source. (See
RefCond370.1.) is cumulatively satisfied for > 5 seconds, since the last time that (Urea Quality Sensor
(UQS) temperature sensor element shorted to a high source. (See RefCond370.1.) is not satisfied AND
Urea Quality Sensor (UQS) temperature sensor element shorted to a low source. (See RefCond374.1.)
is not satisfied).

Cummins Inc. Revision Date: March 30, 2017 600


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

455. 3515.4-SE6982: Aftertreatment 1 Diesel Exhaust Fluid


Temperature 2 Sensor Circuit - Voltage Below Normal or Shorted
to Low Source
The Urea Quality Sensor (UQS) temperature sensing element has been shorted to a low voltage source.

Monitor Operation:
DTC 3515.4-SE6982
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond68.4.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond67.3.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: Urea Quality Sensor (UQS) temperature sensing element shorted to a low source.
(See RefCond33.2.) is cumulatively satisfied for longer than 5 seconds, since the last time that ((Urea
Quality Sensor (UQS) temperature sensor element shorted to a high source. (See RefCond29.2.)) is
not active AND (Urea Quality Sensor (UQS) temperature sensing element shorted to a low source.
(See RefCond33.2.)) is not active).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: Urea Quality Sensor (UQS) temperature sensor element shorted to a low source.
(See RefCond36.2.) is cumulatively satisfied for longer than 5 seconds, since the last time that ((Urea
Quality Sensor (UQS) temperature sensor element shorted to a high source. (See RefCond37.2.)) is
not active AND (Urea Quality Sensor (UQS) temperature sensor element shorted to a low source. (See
RefCond36.2.)) is not active).
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: Urea Quality Sensor (UQS) temperature sensor element shorted to a low source. (See
RefCond374.1.) is cumulatively satisfied for > 5 seconds, since the last time that ((Urea Quality Sensor
(UQS) temperature sensor element shorted to a high source. (See RefCond370.1.)) is not active AND
(Urea Quality Sensor (UQS) temperature sensor element shorted to a low source. (See
RefCond374.1.)) is not active).

Cummins Inc. Revision Date: March 30, 2017 601


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

456. 3521.11-SE8690: Aftertreatment 1 Diesel Exhaust Fluid Property -


Root Cause Not Known
The Urea Quality Sensor (UQS) has determined that the fluid type in the DEF tank is something other
than DEF.

Monitor Operation:
DTC 3521.11-SE8690
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the enable
conditions for the diagnostic are specified as follows (See RefCond60.53.).

Abort Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the disable
conditions for the diagnostic are specified as follows (See RefCond58.49.).

Pause Conditions (any active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) then the pause
conditions for the diagnostic are specified as follows (See RefCond52.37.).

Malfunction Thresholds (all active):


When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the SSI sensors: The fluid type has been detected to be the sensor has completed the DEF type
detection process, and has determined that the fluid in the DEF tank is not DEF (See RefCond39.2.) for
a percentage of time greater than 90 % for a monitoring time window. The monitoring time window
is 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C, and 300 seconds otherwise.
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the WEMA sensors: The fluid type has been detected to be The sensor has completed the DEF type
detection process, and has determined that the fluid in the DEF tank is not DEF. (See RefCond40.1.)
for a percentage of time greater than 90 % for a monitoring time window. The monitoring time
window is 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C, and 300 seconds
otherwise.
When The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.) and the OEM has installed
the TE sensors: The fluid type has been detected to be The sensor has completed the DEF type
detection process, and has determined that the fluid in the DEF tank is not DEF. (See RefCond489.1.)
for a percentage of time greater than 90 % for a monitoring time window. The monitoring time
window is 300 seconds when the initial DEF Tank Temperature at keyon > 10 °C, and 300 seconds
otherwise.

Cummins Inc. Revision Date: March 30, 2017 602


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 603


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

457. 4334.2-SE11203: Aftertreatment 1 Diesel Exhaust Fluid Pressure -


Data Erratic, Intermittent, or Incorrect
Checks if the Doser Module Pressure sensor is In-Range high or low.

Monitor Operation:
DTC 4334.2-SE11203
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 15 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4334.15-SE12047, 4334.3-SE5579, 4334.4-SE5580, 4334.7-SE12048
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 1176.2-SE8698, 1176.2-
SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
The returnline blockage diagnostics is complete when the diagnostics has been enabled for a
calibrated period of time (See RefCond463.2.)
NOT[Conditions to check if the returnline blockage diagnostic error flag has been set. (See
RefCond464.2.)]
Key switch is OFF
DEF dosing module state is Off.
NOT[Engine running condition (See RefCond368.1.)]
NOT [The DEF recirculation is active due to hot shutdown. (See RefCond413.3.)]
NOT [Ambient air temperature is cold (See RefCond412.1.)] prior to key off
Time since The returnline blockage diagnostics is complete when the diagnostics has been enabled for
a calibrated period of time (See RefCond463.2.) becomes active < 15 sec

Abort Conditions (any active):


4334.15-SE12047, 4334.3-SE5579, 4334.4-SE5580, 4334.7-SE12048
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 1176.2-SE8698, 1176.2-
SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
NOT[The returnline blockage diagnostics is complete when the diagnostics has been enabled for a
calibrated period of time (See RefCond463.2.)]
Conditions to check if the returnline blockage diagnostic error flag has been set. (See RefCond464.2.)
Key switch is ON
DEF supply module is not in Off state
The DEF recirculation is active due to hot shutdown. (See RefCond413.3.) AND NOT[Engine running
condition (See RefCond368.1.)]
Ambient air temperature is cold (See RefCond412.1.) prior to key off
Time since The returnline blockage diagnostics is complete when the diagnostics has been enabled for
a calibrated period of time (See RefCond463.2.) becomes active >= 15 sec

Cummins Inc. Revision Date: March 30, 2017 604


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


Absolute pressure value of DEF Doser Module Pressure sensor - absolute pressure value of Ambient
Air Pressure Sensor > 150 kPa(absolute)
Absolute pressure value of Doser Module Pressure sensor - absolute pressure value of Charge
Pressure Sensor > 150 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 605


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

458. 4334.3-SE5579: Aftertreatment 1 Diesel Exhaust Fluid Pressure


Sensor Circuit - Voltage Above Normal or Shorted to High Source
DM pressure sensor reading greater than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 4334.3-SE5579
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


DM pressure raw signal > 4.395V( 1,878.022kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 606


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

459. 4334.4-SE5580: Aftertreatment 1 Diesel Exhaust Fluid Pressure


Sensor Circuit - Voltage Below Normal or Shorted to Low Source
DM pressure sensor reading lower than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 4334.4-SE5580
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 8 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


DM pressure raw signal < 0.135V(1,878.022kPa(absolute))

Cummins Inc. Revision Date: March 30, 2017 607


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

460. 4334.7-SE12048: Aftertreatment 1 Diesel Exhaust Fluid Pressure -


Mechanical System Not Responding or Out of Adjustment
Checks if the Doser Module Pressure sensor is malfunctioning, at Key-Off.

Monitor Operation:
DTC 4334.7-SE12048
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3362.31-SE6980, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.5-SE5102,
5394.7-SE7927
Condition to check the DEF pressure value at the rising event when KeyOff pressure decay diagnostics
is enabled (See RefCond462.2.)
The returnline blockage diagnostics is complete when the diagnostics has been enabled for a
calibrated period of time (See RefCond463.2.)
Conditions to check if the returnline blockage diagnostic error flag has been set. (See RefCond464.2.)
NOT [Conditions to check if the Sensor Stuck diagnostics is complete (See RefCond465.2.)]
NOT [Ambient air temperature is cold (See RefCond412.1.)] prior to key off

Abort Conditions (any active):


3362.31-SE6980, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.5-SE5102,
5394.7-SE7927
Conditions to abort the Key-Off Pressure Decay diagnostics (See RefCond490.2.)
Conditions to check if the Sensor Stuck diagnostics is complete (See RefCond465.2.)
NOT [The returnline blockage diagnostics is complete when the diagnostics has been enabled for a
calibrated period of time (See RefCond463.2.)]
NOT[Conditions to check if the returnline blockage diagnostic error flag has been set. (See
RefCond464.2.)]
Ambient air temperature is cold (See RefCond412.1.) prior to key off

Malfunction Thresholds (all active):


DEF Doser Module pressure captured at (Condition to check the DEF pressure value at the rising event
when KeyOff pressure decay diagnostics is enabled (See RefCond462.2.)) - DEF Doser Module
pressure sample captured after 15sec, for which the injector is fully opened, ≤ 250kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 608


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

461. 520953.3-SE11754: Aftertreatment Diesel Exhaust Fluid Dosing


Unit Relay Feedback - Voltage Above Normal or Shorted to High
Source
DEF Supply Module power relay feedback line is shorted to high voltage.

Monitor Operation:
DTC 520953.3-SE11754
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3361.3-SE7289
3361.4-SE7290
The DEF Supply Module power command is OFF.
The resistance between the DEF Supply Module power driver line and ground ≥ 0.2 Ohms
The resistance between the DEF Supply Module power driver line and ground ≤ 500,000 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery ≥ 0.2 Ohms

Abort Conditions (any active):


3361.4-SE7290
3361.3-SE7289

Pause Conditions (any active):


The DEF Supply Module power command is ON.
The resistance between the DEF Supply Module power driver line and ground > 500,000 Ohms
The resistance between the DEF Supply Module power driver line and ground < 0.2 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery < 0.2 Ohms

Malfunction Thresholds (all active):


DEF Supply Module power feedback voltage > 5 V

Cummins Inc. Revision Date: March 30, 2017 609


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

462. 520953.4-SE11755: Aftertreatment Diesel Exhaust Fluid Dosing


Unit Relay Feedback - Voltage Below Normal or Shorted to Low
Source
DEF Supply Module power relay feedback line is shorted to ground or open circuit.

Monitor Operation:
DTC 520953.4-SE11755
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3361.3-SE7289
3361.4-SE7290
The DEF Supply Module power command is ON.
The resistance between the DEF Supply Module power driver line and ground ≥ 0.2 Ohms
The resistance between the DEF Supply Module power driver line and ground ≤ 500,000 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery ≥ 0.2 Ohms

Abort Conditions (any active):


3361.4-SE7290
3361.3-SE7289

Pause Conditions (any active):


The DEF Supply Module power command is OFF.
The resistance between the DEF Supply Module power driver line and ground > 500,000 Ohms
The resistance between the DEF Supply Module power driver line and ground < 0.2 Ohms
The resistance between the DEF Supply Module power driver line and Vehicle Battery < 0.2 Ohms

Malfunction Thresholds (all active):


DEF Supply Module power feedback voltage ≤ 5 V

Cummins Inc. Revision Date: March 30, 2017 610


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

463. 3362.31-SE6980: Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit


Input Lines - Condition Exists
The diagnostic checks whether the DEF dosing system fails to prime after a calibrated number of
attempts.

Monitor Operation:
DTC 3362.31-SE6980
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Ambient air temperature >= -20 °C OR Ambient air temperature status is not Valid.

Abort Conditions (any active):


Ambient air temperature < -20 °C AND Ambient air temperature status is Valid.

Malfunction Thresholds (all active):


(200 sec has elapsed since dosing system is in (DOSING or PREPARING) state, during this time the DEF
supply pressure does not remain greater than 750 kPa(gauge) and less than 950kPa(gauge) for 3 sec)
AND (NOT[The DEF Supply Module (SM) has completed pump pressure control and is ready to dose.
(See RefCond87.5.)] for a number of occurrences > 5 counts)

Cummins Inc. Revision Date: March 30, 2017 611


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

464. 5394.7-SE7927: Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve


1 - Mechanical System Not Responding or Out of Adjustment
The diagnostic checks whether the DEF Dosing Module Injector valve is mechanically stuck closed or
mechanically stuck open based on the minimum pressure variation observed during On/ Off cycle of
intrusive extended injection period.

Monitor Operation:
DTC 5394.7-SE7927
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


4334.3-SE5579
4334.4-SE5580
4334.16-SE7004
4334.18-SE7005
4375.4-SE6094
4375.3-SE6095
5394.5-SE5102
NOTDosing Not Allowed Flag indicating Dosing command is out of nominal range for Urea Doser
Functional Monitor (See RefCond84.19.)
The DEF Supply Module (SM) has completed pump pressure control and is ready to dose. (See
RefCond87.5.)
DEF supply module pressure ≥ 400 kPa(gauge)
The OBD arbitrator allows the Urea Doser Functional monitor to run
Flag indicating that Engine is in Derate and Urea Doser Functional Response Monitor fault is active.
(See RefCond414.1.)
OR
(
120 sec has elapsed with Exhaust temperature ≥ 230 °C when Engine running condition (See
RefCond368.1.)
(
Ambient air temperature ≥ -6.7 °C OR Ambient air temperature status is not Valid
OR
5394.7-SE7927 is inactive AND test attempts for Urea doser functional response monitor is in
progress
OR
5394.7-SE7927 is active AND Urea doser functional response monitor has started but not completed
255 counts of fault persistent test attempts in a drive cycle
)
)

Cummins Inc. Revision Date: March 30, 2017 612


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Abort Conditions (any active):


4334.3-SE5579
4334.4-SE5580
4334.16-SE7004
4334.18-SE7005
4375.4-SE6094
4375.3-SE6095
5394.5-SE5102
Dosing Not Allowed Flag indicating Dosing command is out of nominal range for Urea Doser
Functional Monitor (See RefCond84.19.)
Not [ The DEF Supply Module (SM) has completed pump pressure control and is ready to dose. (See
RefCond87.5.) ]
DEF supply module pressure < 400 kPa(gauge)
The OBD arbitrator does not allow the Urea Doser Functional monitor to run
NOT [Flag indicating that Engine is in Derate and Urea Doser Functional Response Monitor fault is
active. (See RefCond414.1.)]
AND
(
NOT[Engine running condition (See RefCond368.1.)]
Engine running condition (See RefCond368.1.) AND 120 sec timer not expired. Where: Timer
increments whenever Exhaust temperature ≥ 230 °C
(
Ambient air temperature < -6.7 °C AND Ambient air temperature status is Valid
AND
( 5394.7-SE7927 is inactive AND no test attempts in a Urea doser functional response monitor set are
completed
OR
5394.7-SE7927 is active AND Urea doser functional monitor has either completed 255 counts of fault
persistent test attempts or has not started the sets of fault persistent test attempts in a drive cycle )
)
)

Malfunction Thresholds (all active):


Within intrusive extended injection periods: Maximum DEF supply module pressure - Minimum DEF
supply module pressure should be < 45 kPa(gauge), after ( intrusive extended injection period + 9
seconds) for ≥ 2 counts.

Cummins Inc. Revision Date: March 30, 2017 613


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

465. 5394.5-SE5102: Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve


1 Circuit - Current Below Normal or Open Circuit
Monitor indicates that DEF Dosing Valve High Side Driver Control Line is shorted to ground (STG) or is
experiencing an open load (OL) or Dosing Valve Driver Low Side Control Line is shorted to battery (STB),
is STG or experiencing an OL.

Monitor Operation:
DTC 5394.5-SE5102
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


For malfunction criteria #1, #2, #3, and #4, the Engine Control Module (ECM) has commanded the
Diesel Exhaust Fluid (DEF) Dosing Valve to an OFF state.
For malfunction criteria #2, #5, the Engine Control Module (ECM) has commanded the Diesel Exhaust
Fluid (DEF) Dosing Valve to an ON state.
Keyswitch is ON for ≥ 5 sec

Malfunction Thresholds (all active):


#1 - An open load (OL) situation on the Diesel Exhaust Fluid (DEF) Dosing Valve High Side Driver
Control Line is detected when the resistance between DEF Dosing Valve High Side Channel and the
Ground reference is > 1,000,000 ohms
#2 - A short to low voltage or ground reference (STG) on the Diesel Exhaust Fluid (DEF) Dosing Valve
High Side Driver Control Line is detected when the resistance between DEF Dosing Valve High Side
driver and the ground reference is < 0.2 ohms
#3 - An open load (OL) situation on the Diesel Exhaust Fluid (DEF) Dosing Valve Low Side Driver
Control Line is detected when the resistance between DEF Dosing Valve Low Side Driver and the
ground reference is > 1,000,000 ohms
#4 - A short to low voltage or ground reference (STG) on the Diesel Exhaust Fluid (DEF) Dosing Valve
Low Side Driver Control Line is detected when the resistance between DEF Dosing Valve LSP and the
ground reference is < 0.2 ohms
#5 - A short to high voltage or battery voltage (STB) on the Diesel Exhaust Fluid (DEF) Dosing Valve
Low Side Driver Control Line is detected when the resistance between the DEF Dosing Valve LSP and
the battery voltage reference is < 0.2 ohms

Cummins Inc. Revision Date: March 30, 2017 614


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

466. 5394.3-SE11473: Aftertreatment 1 Diesel Exhaust Fluid Dosing


Valve 1 Circuit - Voltage Above Normal or Shorted to High Source
Monitor indicates that the Diesel Exhaust Fluid (DEF) Dosing Valve High Side Driver Control Line is
shorted to high voltage or battery voltage (STB).

Monitor Operation:
DTC 5394.3-SE11473
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Key switch is ON for < 5 sec

Malfunction Thresholds (all active):


The Engine Control Module (ECM) has detected that the resistance between the Diesel Exhaust Fluid
(DEF) Dosing Valve Low Side Driver Control Line and the ground reference is < 1,000,000 ohms

Cummins Inc. Revision Date: March 30, 2017 615


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

467. 4340.3-SE11170: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


1 Circuit - Voltage Above Normal or Shorted to High Source
Aftertreatment DEF Line Heater 1 electrical voltage is greater than a calibrated threshold for a calibrated
period of time.

Monitor Operation:
DTC 4340.3-SE11170
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Electrical (resistance) heating of the DEF Line has been configured by the OEM.
DEF Line Heater Relay is OFF.

Pause Conditions (any active):


DEF Line Heater Relay is ON.

Malfunction Thresholds (all active):


DEF Line Heater 1 Voltage > 2.5 V

Cummins Inc. Revision Date: March 30, 2017 616


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

468. 4340.4-SE11167: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


1 Circuit - Voltage Below Normal or Shorted to Low Source
Aftertreatment DEF Line Heater 1 electrical voltage is less than or equal to a calibrated threshold for a
calibrated period of time.

Monitor Operation:
DTC 4340.4-SE11167
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


DEF Line Heater Relay is ON.
Electrical (resistance) heating of the DEF Line has been configured by the OEM.

Pause Conditions (any active):


DEF Line Heater Relay is OFF.

Malfunction Thresholds (all active):


DEF Line Heater 1 Voltage ≤ 2.5 V

Cummins Inc. Revision Date: March 30, 2017 617


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

469. 4342.3-SE11171: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


2 Circuit - Voltage Above Normal or Shorted to High Source
Aftertreatment DEF Line Heater 2 electrical voltage is greater than a calibrated threshold for a calibrated
period of time.

Monitor Operation:
DTC 4342.3-SE11171
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Electrical (resistance) heating of the DEF Line has been configured by the OEM.
DEF Line Heater Relay is OFF.

Pause Conditions (any active):


DEF Line Heater Relay is ON.

Malfunction Thresholds (all active):


DEF Line Heater 2 Voltage > 2.5 V

Cummins Inc. Revision Date: March 30, 2017 618


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

470. 4342.4-SE11168: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


2 Circuit - Voltage Below Normal or Shorted to Low Source
Aftertreatment DEF Line Heater 2 electrical voltage is less than or equal to a calibrated threshold for a
calibrated period of time.

Monitor Operation:
DTC 4342.4-SE11168
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


DEF Line Heater Relay is ON.
Electrical (resistance) heating of the DEF Line has been configured by the OEM.

Pause Conditions (any active):


DEF Line Heater Relay is OFF.

Malfunction Thresholds (all active):


DEF Line Heater 2 Voltage ≤ 2.5 V

Cummins Inc. Revision Date: March 30, 2017 619


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

471. 4344.3-SE11172: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


3 Circuit - Voltage Above Normal or Shorted to High Source
Aftertreatment DEF Line Heater 3 electrical voltage is greater than a calibrated threshold for a calibrated
period of time.

Monitor Operation:
DTC 4344.3-SE11172
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Electrical (resistance) heating of the DEF Line has been configured by the OEM.
DEF Line Heater Relay is OFF.

Pause Conditions (any active):


DEF Line Heater Relay is ON.

Malfunction Thresholds (all active):


DEF Line Heater 3 Voltage > 2.5 V

Cummins Inc. Revision Date: March 30, 2017 620


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

472. 4344.4-SE11169: Aftertreatment 1 Diesel Exhaust Fluid Line Heater


3 Circuit - Voltage Below Normal or Shorted to Low Source
Aftertreatment DEF Line Heater 3 electrical voltage is less than or equal to a calibrated threshold for a
calibrated period of time.

Monitor Operation:
DTC 4344.4-SE11169
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


DEF Line Heater Relay is ON.
Electrical (resistance) heating of the DEF Line has been configured by the OEM.

Pause Conditions (any active):


DEF Line Heater Relay is OFF.

Malfunction Thresholds (all active):


DEF Line Heater 3 Voltage ≤ 2.5 V

Cummins Inc. Revision Date: March 30, 2017 621


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

473. 4334.15-SE12047: Aftertreatment 1 Diesel Exhaust Fluid Pressure -


Data Valid But Above Normal Operating Range - Least Severe Level
Checks whether the Doser Module return line from doser to tank is blocked, at Key-Off

Monitor Operation:
DTC 4334.15-SE12047
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3362.31-SE6980, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.5-SE5102,
5394.7-SE7927
Conditions to enable the Key-Off Pressure Decay diagnostics (See RefCond461.2.)
NOT [Ambient air temperature is cold (See RefCond412.1.)] prior to key off
Supply module DEF pressure ≥700kPa(absolute) on rising event of Conditions to enable the Key-Off
Pressure Decay diagnostics (See RefCond461.2.)

Abort Conditions (any active):


3362.31-SE6980, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.5-SE5102,
5394.7-SE7927
NOT [ Conditions to enable the Key-Off Pressure Decay diagnostics (See RefCond461.2.)]
Ambient air temperature is cold (See RefCond412.1.) prior to key off
Supply module DEF pressure <700kPa(absolute) on rising event of Conditions to enable the Key-Off
Pressure Decay diagnostics (See RefCond461.2.)

Malfunction Thresholds (all active):


DEF Doser Module pressure captured at (Condition to check the DEF pressure value at the rising event
when KeyOff pressure decay diagnostics is enabled (See RefCond462.2.)) - DEF Doser Module
pressure sample captured after 20sec, in which the DEF pressure has decayed naturally, ≤
400kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 622


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

474. 3363.18-SE2962: Aftertreatment 1 Diesel Exhaust Fluid Tank


Heater - Data Valid But Below Normal Operating Range -
Moderately Severe Level
The DEF monitor checks whether the DEF tank temperature has failed to reach a target threshold within
a time window after the heating is commanded.

Monitor Operation:
DTC 3363.18-SE2962
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
171.2-SE3871, 171.3-SE3802, 171.4-SE3803
110.3-SE75, 110.4-SE76
Initial DEF tank temperature at Key-On < -10 °C
DEF tank temperature > -30 °C
Coolant temperature > 35 °C
DEF tank heater is active, as disclosed in AECD 13-3.
Engine running condition (See RefCond368.1.)
Diagnostic has not already completed or aborted in this key cycle

Abort Conditions (any active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
171.2-SE3871, 171.3-SE3802, 171.4-SE3803
110.3-SE75, 110.4-SE76
NOT[Engine running condition (See RefCond368.1.)]

Pause Conditions (any active):


Initial DEF tank temperature ≥ -10 °C
DEF tank temperature ≤ -30 °C
Coolant temperature ≤ 30 °C
DEF tank heater is not active, as disclosed in AECD 13-3.
NOT[Engine running condition (See RefCond368.1.)]

Cummins Inc. Revision Date: March 30, 2017 623


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Malfunction Thresholds (all active):


The DEF tank temperature remains less than -4 °C and Doser feedback state is any one of the
following states: Initialization, Standby, Preparing, DEF Error, Service, Off, after the DEF tank heating
is commanded active for RefTable107.2 seconds.

Cummins Inc. Revision Date: March 30, 2017 624


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

475. 3363.7-SE2964: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater


- Mechanical System Not Responding or Out of Adjustment
The monitor checks whether the DEF tank temperature does not rise when DEF tank heating is active

Monitor Operation:
DTC 3363.7-SE2964
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
110.3-SE75, 110.4-SE76
171.2-SE3871, 171.3-SE3802, 171.4-SE3803
( 15 °C - The initial DEF tank temperature at keyon) > 2 °C
-2.5 °C > DEF tank temperature > -30 °C
Coolant temperature > 35 °C
DEF tank heater is active, as disclosed in AECD 13-3.
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
171.2-SE3871, 171.3-SE3802, 171.4-SE3803
110.3-SE75, 110.4-SE76
Coolant temperature ≤ 30 °C
NOT[Engine running condition (See RefCond368.1.)]

Pause Conditions (any active):


-2.5 °C ≤ DEF tank temperature ≤ -30 °C
DEF tank heater is not active, as disclosed in AECD 13-3.
NOT[Engine running condition (See RefCond368.1.)]

Malfunction Thresholds (all active):


(The DEF tank temperature measured within a time window of when the enable conditions are
satisfied - the initial DEF tank temperature when the enable conditions are satisfied) < 2 °C, where the

Cummins Inc. Revision Date: March 30, 2017 625


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

time window is 2,700 sec IF (the initial DEF tank temperature is greater than -8 °C or less than -14 °C),
and the time window is 5,400 sec otherwise

Cummins Inc. Revision Date: March 30, 2017 626


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

476. 3363.16-SE2965: Aftertreatment 1 Diesel Exhaust Fluid Tank


Heater - Data Valid But Above Normal Operating Range -
Moderately Severe Level
The monitor checks whether the DEF tank temperature is too high when tank heating is not active.

Monitor Operation:
DTC 3363.16-SE2965
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
DEF tank heater not active, as disclosed in AECD 13-3.
Engine running condition (See RefCond368.1.)

Abort Conditions (any active):


3363.3-SE6102, 3363.4-SE6103
3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
3031.11-SE8291, 3031.2-SE3650, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666

Pause Conditions (any active):


DEF tank heater is active, as disclosed in AECD 13-3.
NOT[Engine running condition (See RefCond368.1.)]

Malfunction Thresholds (all active):


DEF tank temperature > 75 °C

Cummins Inc. Revision Date: March 30, 2017 627


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

477. 4096.31-SE5279: Aftertreatment Diesel Exhaust Fluid Tank Empty -


Condition Exists
The monitor checks whether the level of DEF in the tank is low and so inducement to refill the tank is
applied

Monitor Operation:
DTC 4096.31-SE5279
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Pause Conditions (any active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Malfunction Thresholds (all active):


1761.1-SE4189 is active AND (The DEF Supply Module has begun filling with DEF (See RefCond77.48.)
at least 3 times OR 4334.18-SE7005 is active)
OR
Fluid level in the DEF tank as measured by the DEF tank level sensor is below the Empty Calibration
set point. (See RefCond267.1.)

Cummins Inc. Revision Date: March 30, 2017 628


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

478. 1761.1-SE2906: Aftertreatment 1 Diesel Exhaust Fluid Tank Level -


Data Valid But Below Normal Operating Range - Most Severe Level
The monitor checks whether the DEF tank is empty

Monitor Operation:
DTC 1761.1-SE2906
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Pause Conditions (any active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Malfunction Thresholds (all active):


DEF tank level < 1 %

Cummins Inc. Revision Date: March 30, 2017 629


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

479. 1761.1-SE4189: Aftertreatment 1 Diesel Exhaust Fluid Tank Level -


Data Valid But Below Normal Operating Range - Most Severe Level
The monitor checks whether there is insufficient DEF in the DEF tank

Monitor Operation:
DTC 1761.1-SE4189
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Pause Conditions (any active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Malfunction Thresholds (all active):


DEF tank level ≤ an OEM defined value which is confined to the range of 2.5 % minimum and 50 %
maximum.

Cummins Inc. Revision Date: March 30, 2017 630


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

480. 1761.17-SE2907: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


- Data Valid But Below Normal Operating Range - Least Severe
Level
The monitor checks whether the DEF tank is low

Monitor Operation:
DTC 1761.17-SE2907
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
1761.1-SE2906
1761.18-SE4188
1761.1-SE4189
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Abort Conditions (any active):


1761.1-SE2906
1761.18-SE4188
1761.1-SE4189

Pause Conditions (any active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Malfunction Thresholds (all active):


DEF tank level <= an OEM defined value which is confined to the range of 10 % minimum and 60 %
maximum.

Cummins Inc. Revision Date: March 30, 2017 631


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

481. 1761.3-SE2896: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


Sensor Circuit - Voltage Above Normal or Shorted to High Source
The DEF tank level sensing element has been shorted to a high voltage source.

Monitor Operation:
DTC 1761.3-SE2896
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When the OEM has installed the analog DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond308.1.).
When the OEM has installed the SSI J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond309.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the enable conditions for the
diagnostic are specified as follows (See RefCond309.2.).
When the OEM has installed the TE J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond309.2.).

Abort Conditions (any active):


When the OEM has installed the analog DEF level sensor: The disable conditions for the diagnostic
are specified as follows. (See RefCond310.1.).
When the OEM has installed the SSI J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond311.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the disable conditions for the
diagnostic are specified as follows (See RefCond311.2.).
When the OEM has installed the TE J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond311.2.).

Pause Conditions (any active):


When the OEM has installed the SSI sensors: ((DEF level detection element voltage shorted out of
range high. (See RefCond259.2.)) is not active AND (Unknown failure of the DEF level detection
element, or DEF level detection element shorted out of range low. (See RefCond260.1.))).
When the OEM has installed the WEMA sensors: (DEF level detection element voltage shorted to a
high source or open circuit. (See RefCond253.2.)) is not active
When the OEM has installed the TE sensors: (DEF level detection element voltage shorted to a high
source or open circuit. (See RefCond491.1.)) is not active

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 632


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

When the OEM has installed and configured the analog DEF level sensor: DEF Tank Level Sensor value
> 4.418 V ( 0 %) for longer than 10 seconds.
When the OEM has installed and configured the J1939 interface SSI DEF level sensor: DEF level
detection element voltage shorted out of range high. (See RefCond259.2.) for > 5 seconds, since the
last time that (DEF level detection element voltage shorted out of range high. (See RefCond259.2.) is
not satisfied AND Unknown failure of the DEF level detection element, or DEF level detection element
shorted out of range low. (See RefCond260.1.) is not satisfied).
When the OEM has installed and configured the J1939 interface WEMA DEF level sensor: DEF level
detection element voltage shorted to a high source or open circuit. (See RefCond253.2.) for > 5
seconds, since the last time that DEF level detection element voltage shorted to a high source or open
circuit. (See RefCond253.2.) is not satisfied AND DEF level detection element voltage shorted to a low
source. (See RefCond252.2.) is not satisfied.
When the OEM has installed and configured the J1939 interface TE DEF level sensor: DEF level
detection element voltage shorted to a high source or open circuit. (See RefCond491.1.) for > 5
seconds, since the last time that DEF level detection element voltage shorted to a high source or open
circuit. (See RefCond491.1.) is not satisfied AND DEF level detection element voltage shorted to a low
source. (See RefCond492.1.) is not satisfied.

Cummins Inc. Revision Date: March 30, 2017 633


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

482. 1761.4-SE2897: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


Sensor Circuit - Voltage Below Normal or Shorted to Low Source
DEF Tank Level Sensor reading lower than specified operating range for a calibrated amount of time.

Monitor Operation:
DTC 1761.4-SE2897
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When the OEM has installed the analog DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond254.1.).
When the OEM has installed the WEMA J1939 DEF level sensor: the enable conditions for the
diagnostic are specified as follows (See RefCond256.4.).
When the OEM has installed the TE J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond256.4.).

Abort Conditions (any active):


When the OEM has installed the analog DEF level sensor: the disable conditions for the diagnostic are
specified as follows (See RefCond257.1.).
When the OEM has installed the WEMA J1939 DEF level sensor: the disable conditions for the
diagnostic are specified as follows (See RefCond258.4.).
When the OEM has installed the TE J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond258.4.).

Malfunction Thresholds (all active):


When the OEM has installed and configured the J1939 interface WEMA DEF level sensor: DEF level
detection element voltage shorted to a low source. (See RefCond252.2.) for > 5 seconds, since the last
time that (DEF level detection element voltage shorted to a high source or open circuit. (See
RefCond253.2.) is not satisfied AND DEF level detection element voltage shorted to a low source. (See
RefCond252.2.) is not satisfied).
When the OEM has installed and configured the J1939 interface TE DEF level sensor: DEF level
detection element voltage shorted to a low source. (See RefCond492.1.) for > 5 seconds, since the last
time that (DEF level detection element voltage shorted to a high source or open circuit. (See
RefCond491.1.) is not satisfied AND DEF level detection element voltage shorted to a low source. (See
RefCond492.1.) is not satisfied).
When the OEM has installed and configured the analog DEF level sensor: DEF Tank Level Sensor value
< 0.235 V (100 % ) for longer than 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 634


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

483. 1761.10-SE8684: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


Sensor - Abnormal Rate of Change
The DEF tank level sensor has been unable to generate a level estimate for longer than the maximum
wait time threshold, due to unsuitable measurement conditions.

Monitor Operation:
DTC 1761.10-SE8684
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When the OEM has installed the SSI J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond261.22.).
When the OEM has installed the WEMA J1939 DEF level sensor: the enable conditions for the
diagnostic are specified as follows (See RefCond261.22.).

Abort Conditions (any active):


When the OEM has installed the SSI J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond262.22.).
When the OEM has installed the WEMA J1939 DEF level sensor: the disable conditions for the
diagnostic are specified as follows (See RefCond262.22.).

Pause Conditions (any active):


When the OEM has installed the SSI J1939 DEF level sensor: the pause conditions for the diagnostic
are specified as follows (See RefCond263.22.).
When the OEM has installed the WEMA J1939 DEF level sensor: the pause conditions for the
diagnostic are specified as follows (See RefCond263.22.).

Malfunction Thresholds (all active):


When the OEM has installed and configured the J1939 interface SSI DEF level sensor: (The DEF level
sensor smart device controller is in the process of initializing, OR the DEF fluid is frozen or not
present) for longer than a validation time. The validation time is equal to 7,200 seconds when the
initial DEF Tank Temperature at keyon > 5 °C, and the validation time is equal to 7,200 seconds
otherwise.
When the OEM has installed and configured the J1939 interface WEMA DEF level sensor: The DEF
level sensor smart device controller is in the process of initializing for longer than a validation time.
The validation time is equal to 7,200 seconds when the initial DEF Tank Temperature at keyon > 5 °C,
and the validation time is equal to 7,200 seconds otherwise.

Cummins Inc. Revision Date: March 30, 2017 635


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

Cummins Inc. Revision Date: March 30, 2017 636


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

484. 1761.11-SE8293: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


Sensor - Root Cause Not Known
The DEF tank level sensing element is in a 'Root Cause not Known' state.

Monitor Operation:
DTC 1761.11-SE8293
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


When the OEM has installed the SSI J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond312.2.).

Abort Conditions (any active):


When the OEM has installed the SSI J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond313.2.).

Pause Conditions (any active):


When the OEM has installed the SSI sensors: ((Unknown failure of the DEF level detection element, or
DEF level detection element shorted out of range low. (See RefCond260.1.)) is not active, AND (DEF
level detection element voltage shorted out of range high. (See RefCond259.2.))).

Malfunction Thresholds (all active):


When the OEM has installed and configured the J1939 interface SSI DEF level sensor: Unknown
failure of the DEF level detection element, or DEF level detection element shorted out of range low.
(See RefCond260.1.) for greater than 5 seconds, since the last time that (DEF level detection element
voltage shorted out of range high. (See RefCond259.2.) is not satisfied, AND Unknown failure of the
DEF level detection element, or DEF level detection element shorted out of range low. (See
RefCond260.1.) is not satisfied).

Cummins Inc. Revision Date: March 30, 2017 637


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

485. 1761.18-SE4188: Aftertreatment 1 Diesel Exhaust Fluid Tank Level


- Data Valid But Below Normal Operating Range - Moderately
Severe Level
The monitor checks whether the DEF tank is at the low warning level

Monitor Operation:
DTC 1761.18-SE4188
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Entry Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
1761.1-SE4189
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Abort Conditions (any active):


1761.1-SE4189

Pause Conditions (any active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897, 1761.9-SE7665
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Malfunction Thresholds (all active):


DEF tank level <= an OEM defined value which is confined to the range of 2.5 % minimum and 55 %
maximum.

Cummins Inc. Revision Date: March 30, 2017 638


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

486. 3031.2-SE3650: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature - Data Erratic, Intermittent, or Incorrect
The monitor indicates whether the DEF Tank Temperature signal is in-range but not rational

Monitor Operation:
DTC 3031.2-SE3650
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
110.3-SE75, 110.4-SE76
105.2-SE3793, 105.3-SE487, 105.4-SE488
A block heater is not detected. (See RefCond174.3.)
The engine is cold soaked (See RefCond232.1.)
The diagnostic runs only once per key cycle.

Abort Conditions (any active):


3031.11-SE8291, 3031.3-SE2898, 3031.4-SE2899, 3031.9-SE7666
110.3-SE75, 110.4-SE76
105.2-SE3793, 105.3-SE487, 105.4-SE488

Malfunction Thresholds (all active):


|DEF Tank Temperature - Charge Temperature measured at keyon| > 40 °C
|DEF Tank Temperature - Coolant Temperature measured at keyon| > 40 °C

Cummins Inc. Revision Date: March 30, 2017 639


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

487. 3031.3-SE2898: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature Sensor - Voltage Above Normal or Shorted to High
Source
The DEF tank temperature sensing element has been shorted to a high voltage source

Monitor Operation:
DTC 3031.3-SE2898
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When the OEM has installed the SSI J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond250.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the enable conditions for the
diagnostic are specified as follows (See RefCond250.2.).
When the OEM has installed the TE J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond250.2.).

Abort Conditions (any active):


When the OEM has installed the SSI J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond249.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the disable conditions for the
diagnostic are specified as follows (See RefCond249.2.).
When the OEM has installed the TE J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond249.2.).

Pause Conditions (any active):


When the OEM has installed the SSI sensors: ((DEF tank temperature sensor element shorted to a
high source. (See RefCond225.1.)) is not active AND (DEF tank temperature sensor element shorted to
a low source. (See RefCond226.1.))).
When the OEM has installed the WEMA sensors: ((DEF tank temperature sensor element shorted to a
high source or open circuit. (See RefCond227.2.)) is not active AND (DEF tank temperature sensor
element shorted to a low source. (See RefCond231.2.))).
When the OEM has installed the TE sensors: ((DEF tank temperature sensor element shorted to a high
source or open circuit. (See RefCond459.1.)) is not active AND (DEF tank temperature sensor element
shorted to a low source. (See RefCond460.1.))).

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 640


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

When the OEM has installed the analog DEF level sensor: DEF Tank Temperature Sensor value > 4.883
V (< -50 °C) for longer than 10 seconds
When the OEM has installed and configured the J1939 interface SSI DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a high source. (See RefCond225.1.) for > 5 seconds,
since the last time that (DEF tank temperature sensor element shorted to a high source. (See
RefCond225.1.) is not satisfied AND DEF tank temperature sensor element shorted to a low source.
(See RefCond226.1.) is not satisfied).
When the OEM has installed and configured the J1939 interface WEMA DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a high source or open circuit. (See RefCond227.2.)
for > 5 seconds, since the last time that (DEF tank temperature sensor element shorted to a high
source or open circuit. (See RefCond227.2.) is not satisfied AND DEF tank temperature sensor
element shorted to a low source. (See RefCond231.2.) is not satisfied).
When the OEM has installed and configured the J1939 interface TE DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a high source or open circuit. (See RefCond459.1.)
for > 5 seconds, since the last time that (DEF tank temperature sensor element shorted to a high
source or open circuit. (See RefCond459.1.) is not satisfied AND DEF tank temperature sensor
element shorted to a low source. (See RefCond460.1.) is not satisfied).

Cummins Inc. Revision Date: March 30, 2017 641


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

488. 3031.4-SE2899: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature Sensor - Voltage Below Normal or Shorted to Low
Source
The DEF tank temperature sensing element has been shorted to a low voltage source

Monitor Operation:
DTC 3031.4-SE2899
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


When the OEM has installed the SSI J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond229.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the enable conditions for the
diagnostic are specified as follows (See RefCond229.2.).
When the OEM has installed the TE J1939 DEF level sensor: the enable conditions for the diagnostic
are specified as follows (See RefCond229.2.).

Abort Conditions (any active):


When the OEM has installed the SSI J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond230.2.).
When the OEM has installed the WEMA J1939 DEF level sensor: the disable conditions for the
diagnostic are specified as follows (See RefCond230.2.).
When the OEM has installed the TE J1939 DEF level sensor: the disable conditions for the diagnostic
are specified as follows (See RefCond230.2.).

Pause Conditions (any active):


When the OEM has installed the SSI sensors: ((DEF tank temperature sensor element shorted to a low
source. (See RefCond226.1.)) is not active AND (DEF tank temperature sensor element shorted to a
high source. (See RefCond225.1.))).
When the OEM has installed the WEMA sensors: ((DEF tank temperature sensor element shorted to a
low source. (See RefCond231.2.)) is not active AND (DEF tank temperature sensor element shorted to
a high source or open circuit. (See RefCond227.2.))).
When the OEM has installed the TE sensors: ((DEF tank temperature sensor element shorted to a low
source. (See RefCond460.1.)) is not active AND (DEF tank temperature sensor element shorted to a
high source or open circuit. (See RefCond459.1.))).

Malfunction Thresholds (all active):

Cummins Inc. Revision Date: March 30, 2017 642


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

When the OEM has installed the analog DEF level sensor: DEF Tank Temperature Sensor value < 0.153
V (> 75 °C) for longer than 10 seconds
When the OEM has installed and configured the J1939 interface SSI DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a low source. (See RefCond226.1.) for > 5 seconds,
since the last time that (DEF tank temperature sensor element shorted to a high source. (See
RefCond225.1.) is not satisfied AND DEF tank temperature sensor element shorted to a low source.
(See RefCond226.1.) is not satisfied).
When the OEM has installed and configured the J1939 interface WEMA DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a low source. (See RefCond231.2.) for > 5 seconds,
since the last time that (DEF tank temperature sensor element shorted to a high source or open
circuit. (See RefCond227.2.) is not satisfied AND DEF tank temperature sensor element shorted to a
low source. (See RefCond231.2.) is not satisfied).
When the OEM has installed and configured the J1939 interface TE DEF tank temperature sensor:
DEF tank temperature sensor element shorted to a low source. (See RefCond460.1.) for > 5 seconds,
since the last time that (DEF tank temperature sensor element shorted to a high source or open
circuit. (See RefCond459.1.) is not satisfied AND DEF tank temperature sensor element shorted to a
low source. (See RefCond460.1.) is not satisfied).

Cummins Inc. Revision Date: March 30, 2017 643


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

489. 3031.11-SE8291: Aftertreatment 1 Diesel Exhaust Fluid Tank


Temperature - Root Cause Not Known
The DEF tank temperature sensing element has been detected to have an internal error.

Monitor Operation:
DTC 3031.11-SE8291
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The enable conditions for the DEF Tank Temperature Internal error diagnostic are specified as follows
(See RefCond480.1.).

Abort Conditions (any active):


The disable conditions for the DEF Tank Temperature Internal error diagnostic are specified as follows
(See RefCond481.1.).

Pause Conditions (any active):


FMI 11 J1939 indication is not received from OEM supplied device AND indication for any other FMI is
received from the OEM supplied device.

Malfunction Thresholds (all active):


FMI 11 J1939 indication received from OEM supplied device, which meets requirements as set forth
in the Cummins AEB, is cumulatively satisfied for 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 644


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

490. 5491.3-SE6100: Aftertreatment Diesel Exhaust Fluid Line Heater


Relay - Voltage Above Normal or Shorted to High Source
DEF line heater relay driver control line is shorted to high source.

Monitor Operation:
DTC 5491.3-SE6100
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 1 trip

Entry Conditions (all active):


The DEF line heater relay command is ON.

Pause Conditions (any active):


The DEF line heater relay command is OFF.

Malfunction Thresholds (all active):


The resistance between the DEF line heater relay driver line and Vehicle Battery < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 645


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

491. 5491.4-SE6101: Aftertreatment Diesel Exhaust Fluid Line Heater


Relay - Voltage Below Normal or Shorted to Low Source
DEF line heater relay driver control line is shorted to ground or open circuit

Monitor Operation:
DTC 5491.4-SE6101
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The DEF line heater relay command is OFF

Pause Conditions (any active):


The DEF line heater relay command is ON.

Malfunction Thresholds (all active):


The resistance between the DEF line heater relay driver line and Vehicle Battery > 500,000 Ohms
The resistance between the DEF line heater relay driver line and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 646


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

492. 3363.3-SE6102: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater


- Voltage Above Normal or Shorted to High Source
DEF tank heater valve driver control line is shorted to high source or open circuit.

Monitor Operation:
DTC 3363.3-SE6102
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


0% <= Duty cycle of DEF tank heater relay command <= 99%

Pause Conditions (any active):


0% >= Duty cycle of DEF tank heater relay command >= 99%

Malfunction Thresholds (all active):


The resistance between the DEF tank heater valve driver line and ground > 500,000 Ohms
The resistance between the DEF tank heater valve driver line and battery < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 647


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

493. 3363.4-SE6103: Aftertreatment 1 Diesel Exhaust Fluid Tank Heater


- Voltage Below Normal or Shorted to Low Source
DEF tank heater valve driver control line is shorted to ground.

Monitor Operation:
DTC 3363.4-SE6103
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 2 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


The DEF tank heater relay command is ON.

Pause Conditions (any active):


The DEF tank heater relay command is OFF.

Malfunction Thresholds (all active):


The resistance between the DEF tank heater valve driver line and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 648


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

494. 5321.31-SE8281: Engine Intake Manifold Pressure System Monitor


- Condition Exists
Measured Delta Pressure over Pressure (DPOP) is lower than commanded DPOP when the DPOP
controller has used up all allowed adjustment. DPOP is defined as (Exhaust Pressure - Charge Pressure) /
Charge Pressure.

Monitor Operation:
DTC 5321.31-SE8281
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 2 trips

Pause Conditions (any active):


27.2-SE3866, 27.2-SE3867, 27.3-SE3202, 27.4-SE3203, 2791.13-SE3980, 2791.3-SE2797, 2791.3-
SE3582, 2791.4-SE2798
3464.3-SE12370, 3464.3-SE12372, 3464.4-SE12371, 51.2-SE4014, 51.2-SE4015, 51.3-SE3530, 51.4-
SE3529
1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490
VGT driver failure (See RefCond143.3.)
The EGR H-bridge valve position is not valid. (See RefCond146.5.)
The Intake Air Throttle Valve Position is not known to be good. (See RefCond145.4.)
The VGT Position is not known to be good. (See RefCond144.4.)
EGR Off Engine Protection is active
EGR Delta Pressure sensor autozero check is not complete
Engine Thermal Management Mode 1 is inactive
Filtered (tau = 1.9 sec) Charge Temperature ≤ 15 °C
Filtered (tau = 1.9 sec) EGR Orifice Temperature ≤ 15 °C
NOT [(Engine is in run state AND Ambient Air Temperature > -6.67 DegC AND Ambient Air Pressure >
75 kPa(absolute)) FOR ≥ 0.01 sec]

Malfunction Thresholds (all active):


(Estimated EGR Delta Pressure Over Pressure - EGR Delta Pressure Over Pressure ≥ 3.2 kPa AND VGT
is fully open AND EGR Valve is fully closed AND Intake Air Throttle is fully closed) FOR a total of 10 sec
within a 45 sec window.

Cummins Inc. Revision Date: March 30, 2017 649


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

495. 641.7-SE1606: VGT Actuator Driver Circuit (Motor) - Mechanical


System Not Responding or Out of Adjustment
The turbocharger smart device actuator has determined itself to be incapable of meeting its desired
position. This is communicated to the ECM via a number of status codes.

Monitor Operation:
DTC 641.7-SE1606
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


As there may be a number of malfunction criteria that apply, the enable conditions may be matched
to the corresponding malfunction criteria by the word or phrase at the beginning of the condition.
Slow Actuator Response: Coolant Temperature < 85 deg C OR Engine has not been running for >= 300
seconds
NOT[Slow Actuator Response: The engine conditions must be appropriate to avoid a false detect of a
stuck actuator. (See RefCond176.4.)]

Malfunction Thresholds (all active):


If ANY of the following apply, the error will be set:
Slow Actuator Response: The turbocharger smart device has detected that it cannot meet its
commanded position within an acceptable time. (See RefCond177.5.)

Cummins Inc. Revision Date: March 30, 2017 650


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

496. 641.11-SE1627: VGT Actuator Driver Circuit - Root Cause Not


Known
The turbocharger smart device actuator has not received a command message from the controlling ECM
for a calibrated period.

Monitor Operation:
DTC 641.11-SE1627
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria 1 trip

Pause Conditions (any active):


The turbocharger smart device is performing a self calibration: checking for span and end points.

Malfunction Thresholds (all active):


Message Timeout: The turbocharger smart device has not received a position command message for
greater than or equal to a calibrated time after previously having received a command message. (See
RefCond179.1.)
OR
No Source: The turbocharger smart device has not received a message from the ECM. (See
RefCond180.1.)

Cummins Inc. Revision Date: March 30, 2017 651


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

497. 641.12-SE1604: VGT Actuator Controller - Bad Intelligent Device or


Component
The turbocharger smart device has detected an internal error which will prevent it from functioning
normally.

Monitor Operation:
DTC 641.12-SE1604
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The turbocharger smart device has detected an internal error which will prevent it from functioning
normally. (See RefCond182.1.)

Cummins Inc. Revision Date: March 30, 2017 652


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

498. 641.14-SE1605: VGT Actuator Controller - Special Instructions


The turbocharger smart device position sensing or physical endstops were not detected during
initialization procedure, or the turbocharger smart device indicates it is in a condition without known
calibration data.

Monitor Operation:
DTC 641.14-SE1605
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The turbocharger smart device has not detected a physical stop during the powerup process. (See
RefCond184.1.)
OR
The VGT device reports that it is in a state with no known calibration data.
OR
The VGT device reports that it is in the process of doing an installation.

Cummins Inc. Revision Date: March 30, 2017 653


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

499. 641.15-SE1607: VGT Actuator Driver Temperature - Data Valid But


Above Normal Operating Range - Least Severe Level
The turbocharger smart device has detected a temperature in excess of internal limits.

Monitor Operation:
DTC 641.15-SE1607
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,800 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


The turbocharger smart device has detected a warm temperature condition. (See RefCond307.2.)

Cummins Inc. Revision Date: March 30, 2017 654


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

500. 3597.4-SE1602: ECU Power Output Supply Voltage 1 - Voltage


Below Normal or Shorted to Low Source
The ECM has detected the voltage to the turbocharger smart device is less than an allowable value.

Monitor Operation:
DTC 3597.4-SE1602
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 6 sec
MIL Activation Criteria 1 trip

Malfunction Thresholds (all active):


The power supply to the turbocharger smart device is < 6.7 V.

Cummins Inc. Revision Date: March 30, 2017 655


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

501. 3597.18-SE1626: ECU Power Output Supply Voltage 1 - Data Valid


But Below Normal Operating Range - Moderately Severe Level
The turbocharger smart device has detected a low voltage condition.

Monitor Operation:
DTC 3597.18-SE1626
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 30 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


Engine Speed < 575 RPM.

Malfunction Thresholds (all active):


The voltage for the turbocharger smart device is less than a calibrated value. (See RefCond187.1.)

Cummins Inc. Revision Date: March 30, 2017 656


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

502. 84.2-SE7458: Wheel-Based Vehicle Speed - Data Erratic,


Intermittent, or Incorrect
Vehicle Speed Sensor In Range High Error at keyoff.

Monitor Operation:
DTC 84.2-SE7458
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Key switch is OFF.
Engine Speed = 0 RPM

Abort Conditions (any active):


Key Switch in ON
Engine Speed ≠ 0 RPM

Malfunction Thresholds (all active):


At key off Vehicle Speed > 9.942 mph

Cummins Inc. Revision Date: March 30, 2017 657


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

503. 84.2-SE7483: Wheel-Based Vehicle Speed - Data Erratic,


Intermittent, or Incorrect
Vehicle Speed Sensor In Range Low Error.

Monitor Operation:
DTC 84.2-SE7483
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1,800 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Road speed governor is inactive
Cruise control is inactive
PTO is inactive
Remote accelerator is inactive
Auxiliary device is not in control of the engine.
SCR Inducement is INACTIVE.
No Torque Derates are ACTIVE.

Abort Conditions (any active):


Road speed governor is active
PTO is active
Cruise control is active
Remote accelerator is active
Auxiliary device is in control of the engine.
SCR Inducement is ACTIVE.
Torque derate is ACTIVE.

Malfunction Thresholds (all active):


Vehicle Speed lies continuously between 3.107 mph and 12.427 mph

Cummins Inc. Revision Date: March 30, 2017 658


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

504. 84.2-SE4360: Wheel-Based Vehicle Speed - Data Erratic,


Intermittent, or Incorrect
Vehicle Speed Sensor In Range High Error.

Monitor Operation:
DTC 84.2-SE4360
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 300 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Engine Torque ≥ 200 Nm
PTO is inactive
Auxiliary device is not in control of the engine.
Remote accelerator is inactive

Abort Conditions (any active):


Engine Torque < 200 Nm
PTO is active
Auxiliary device is in control of the engine.
Remote accelerator is active

Malfunction Thresholds (all active):


Actual Gear Ratio < 0.584 (ratio)

Cummins Inc. Revision Date: March 30, 2017 659


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

505. 84.2-SE4361: Wheel-Based Vehicle Speed - Data Erratic,


Intermittent, or Incorrect
Vehicle Speed Sensor Stuck In Range Error.

Monitor Operation:
DTC 84.2-SE4361
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 600 sec
MIL Activation Criteria 2 trips

Entry Conditions (all active):


Road speed governor is inactive
Cruise control is inactive
PTO is inactive
Remote accelerator is inactive
Vehicle Speed > 0mph
Auxiliary device is not in control of the engine.

Abort Conditions (any active):


84.2-SE130
Vehicle Speed = 0 mph
Road speed governor is active
PTO is active
Cruise control is active
Remote accelerator is active
Auxiliary device is in control of the engine.

Malfunction Thresholds (all active):


Difference between min and max vehicle speeds attained within a time window is less than 0.621
mph, while pedal position has changed by 20 % atleast 30 number of times in the time window.

Cummins Inc. Revision Date: March 30, 2017 660


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

506. 84.2-SE130: Wheel-Based Vehicle Speed - Data Erratic,


Intermittent, or Incorrect
Vehicle Speed Signal is lost while vehicle is stationary or while vehicle is moving.

Monitor Operation:
DTC 84.2-SE130
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 1 sec
MIL Activation Criteria 2 trips

Pause Conditions (any active):


PTO is active.
Auxiliary device is in control of the engine.
Remote accelerator is active

Malfunction Thresholds (all active):


For Physical Sensors and Datalink sensors: Vehicle Speed = 0 mph
Engine Speed > 10 RPM
(Boost transition counter >= 10 counts OR (Net Brake Torque > 380 Nm FOR ≥ 15 sec))
Idle Validation counter >= 10 counts
Where Idle Validation Counter is incremented on Idle transitions from idle to non-idle, and Boost
transition counter is incremented when Boost pressure goes above 100 kPa(gauge) FOR ≥ 5 sec.
Additional check for physical sensors: After the engine has been running for ≥ 300 sec, (Engine Torque
> 116 Nm) AND (Unfiltered Vehicle Speed = 0 mph) AND (Filtered Vehicle Speed > 9.942 mph)

Cummins Inc. Revision Date: March 30, 2017 661


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

507. 97.15-SE280: Water in Fuel Indicator - Data Valid But Above


Normal Operating Range - Least Severe Level
Water has been detected in the fuel filter

Monitor Operation:
DTC 97.15-SE280
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 20 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Water In Fuel Sensor Voltage ≤ 2.922 V

Cummins Inc. Revision Date: March 30, 2017 662


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

508. 97.16-SE1612: Water in Fuel Indicator - Data Valid But Above


Normal Operating Range - Moderately Severe Level
The Water In Fuel sensor indicates that water has been detected in the fuel filter for an extensive
amount of time or distance traveled.

Monitor Operation:
DTC 97.16-SE1612
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration Immediate
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Water In Fuel Detected Time >= 8 hr

Cummins Inc. Revision Date: March 30, 2017 663


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

509. 97.3-SE660: Water in Fuel Indicator Sensor Circuit - Voltage Above


Normal or Shorted to High Source
Water In Fuel Out of Range Error High

Monitor Operation:
DTC 97.3-SE660
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 10 sec
MIL Activation Criteria Non-OBD

Malfunction Thresholds (all active):


Filtered output value of the Water in Fuel sensor > 4.922 V

Cummins Inc. Revision Date: March 30, 2017 664


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

510. 1081.7-SE7231: Engine Wait to Start Lamp - Mechanical System


Not Responding or Out of Adjustment
The Wait to Start Lamp Driver ECM feedback circuit resistance is different than expected.

Monitor Operation:
DTC 1081.7-SE7231
Monitor Execution Continuous
Monitor Sequence None
Sensors OK None
Typical Monitoring Duration 3 sec
MIL Activation Criteria 2 trips

Malfunction Thresholds (all active):


Resistance between the Wait to Start Lamp Driver and voltage source < 0.2 Ohms OR Resistance
between the Wait to Start Lamp Driver and voltage source > 500,000 Ohms OR Resistance between
the Wait to Start Lamp Driver and ground < 0.2 Ohms

Cummins Inc. Revision Date: March 30, 2017 665


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

511. RefCondRefCond3.7: Exhaust gas temperature is below a threshold


representing that dew point is not reached
Exhaust gas temperature is below a threshold representing that dew point is not reached

Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
OR
The SCR Out temperature as measured by the thermistor closest to the SONOx sensor < 160 degC.
OR
NOT[Engine running condition (See RefCond368.1.)] for time a time period > 0.2 sec
OR
NOx Outlet sensor SCR hot start delay logic is allowed to run. (See RefCond5.4.)

Cummins Inc. Revision Date: March 30, 2017 666


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

512. RefCondRefCond4.4: SCR Outlet Temperature sensor reading is


valid.
SCR Outlet Temperature sensor reading is valid.

Conditions (all active):


4363.2-SE13180, 4363.2-SE3785, 5862.2-SE2895
4363.3-SE6762, 4363.4-SE6763, 5743.12-SE6765
SCR Outlet Temperature sensor signal contains valid data.
NOT[SCR Outlet temperature sensor data is not available and not yet confirmed as faulty. (See
RefCond418.2.)]
NOT[SCR Out temperature sensor reading no value and not yet confirmed as faulty. (See
RefCond420.1.)]

Cummins Inc. Revision Date: March 30, 2017 667


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

513. RefCondRefCond5.4: NOx Outlet sensor SCR hot start delay logic is
allowed to run.
NOx Outlet sensor SCR hot start delay logic is allowed to run.

Conditions (all active):


(
Average SCR out temperature buffer is not full (See RefCond454.1.)
OR
SCR out temperature ≥ 200 DegC for at least 30 sec AND Over a 30 sec window, the derivative of SCR
Outlet temperature < 0 DegC/sec
)
SCR Out temperature as measured by the thermistor closest to the SONOx sensor ≥ 200 °C
SCR Outlet Temperature sensor reading is valid. (See RefCond4.4.)
Engine running condition (See RefCond368.1.)

Cummins Inc. Revision Date: March 30, 2017 668


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

514. RefCondRefCond7.6: Exhaust gas temperature is above a threshold


representing the point at which there is no longer a concern of
condensation on the NOx sensor element.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element.

Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
The exhaust temperature as measured by the sensor closest to the Aftertreatment Inlet NOx sensor >
150 degC for RefTable69.3 seconds when engine is running, AND Estimated aftertreatment inlet gas
temperature is valid. (See RefCond188.4.) , AND dew point has not met in this cycle else The exhaust
temperature as measured by the sensor closest to the Aftertreatment Inlet NOx sensor > 150 degC
for 5 seconds.
Engine is running or Engine is not running for < 0.2 sec

Cummins Inc. Revision Date: March 30, 2017 669


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

515. RefCondRefCond8.5: NOx sensor reading is not valid due to


internal control loops within the sensor being unstable..
NOx sensor reading is not valid due to internal control loops within the sensor being unstable..

Conditions (all active):


[Ref/M2] The voltage between the sensor measuring electrode in the 2nd pumping chamber and the
air reference electrode is not within 40 mV of its setpoint for over 0.2 seconds.
OR [P+/M2] The rate of change in current from the sensor measuring electrode in the 2nd pumping
chamber to the sensor top electrode(directly exposed to exhaust gas) is not within 42.6 nA/msec for
over 20 ms.
OR [M1/P+] The current from the sensor measuring electrode in the 2nd pumping chamber to the
sensor top electrode (directly exposed to exhaust gas) is larger than 19 uA for over 0.2 seconds.
OR [M1/P+] The current from the sensor measuring electrode in the 2nd pumping chamber to the
sensor top electrode (directly exposed to the exhaust gas) is less than -40 uA for over 0.2 seconds.
OR [M1/P+] The current from the sensor pumping electrode in the 2nd pumping chamber to the
sensor top electrode (directly exposed to exhaust gas) is not within 2.4 uA of its setpoint for over 2
seconds.

Cummins Inc. Revision Date: March 30, 2017 670


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

516. RefCondRefCond9.6: Exhaust gas temperature is below a threshold


or above a threshold for insufficient time representing that dew
point is not reached.
Exhaust gas temperature is below a threshold or above a threshold for insufficient time representing
that dew point is not reached.

Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
OR the exhaust temperature as measured by the sensor closest to the Aftertreatment Inlet NOx
Sensor < 140 degC
OR The exhaust temperature as measured by the sensor closest to the Aftertreatment Inlet NOx
Sensor > 150 degC for less than RefTable69.3 seconds when engine is running, AND Estimated
aftertreatment inlet gas temperature is valid. (See RefCond188.4.) , AND dew point has not met in
this cycle else The exhaust temperature as measured by the sensor closest to the Aftertreatment Inlet
NOx Sensor > 150 degC for less than 5 seconds.
OR Engine is not running for > 0.2 sec

Cummins Inc. Revision Date: March 30, 2017 671


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

517. RefCondRefCond10.4: Datalinks-related faults are inhibited for a


calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a
stop/suspend broadcast event. This is to allow reasonable time for
datalink devices to power up and begin periodic broadcasts before
the ECM performs time-out diagnostics.
Datalinks-related faults are inhibited for a calibratable amount of time following a key-on event, a low
battery voltage event, an engine cranking event, and a stop/suspend broadcast event. This is to allow
reasonable time for datalink devices to power up and begin periodic broadcasts before the ECM
performs time-out diagnostics.

Conditions (all active):


( ( Engine Position Sensor has determined that the engine has transitioned from stopped to a non-
stopped state. AND Engine Speed > ( Idle reference speed - 100 RPM) ) AND J1939 DM13 stop
broadcast message has not been active. AND Key Switch is ON ) for at least 30,000 msec.

Cummins Inc. Revision Date: March 30, 2017 672


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

518. RefCondRefCond17.3: NOx sensor reading is valid since the


internal control loops within the sensor have stabilized.
NOx sensor reading is valid since the internal control loops within the sensor have stabilized.

Conditions (all active):


[Ref/M2] The voltage between the sensor measuring electrode in the 2nd pumping chamber and the
air reference electrode is within 40 mV of its setpoint for over 0.2 seconds.
OR [P+/M2] The rate of change in current from the sensor measuring electrode in the 2nd pumping
chamber to the sensor top electrode(directly exposed to exhaust gas) is within 42.6 nA/msec for
over 20 ms.
OR [M1/P+] The current from the sensor measuring electrode in the 2nd pumping chamber to the
sensor top electrode (directly exposed to exhaust gas) < 19 uA OR > -40 uA for over 0.2 seconds.
OR [M1/P+] The current from the sensor pumping electrode in the 2nd pumping chamber to the
sensor top electrode (directly exposed to exhaust gas) is within 2.4 uA of its setpoint for over 2
seconds.

Cummins Inc. Revision Date: March 30, 2017 673


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

519. RefCondRefCond19.8: Exhaust gas temperature is above a


threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element.

Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
The SCR Out temperature as measured by the sensor closest to the SONOx sensor is above a
processed threshold for a calculated period of time. (See RefCond18.8.)
NOT[Engine running condition (See RefCond368.1.)] for a time period < 0.2 sec
NOT [NOx Outlet sensor SCR hot start delay logic is allowed to run. (See RefCond5.4.)]

Cummins Inc. Revision Date: March 30, 2017 674


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

520. RefCondRefCond20.10: Aftertreatment Outlet NOx sensor reading


is valid since the internal control loops within the sensor are
stable, and no active faults detected by the sensor, and the
sensor's battery supply voltage is within the desired range and
dewpoint temperature has been met for a sufficient time to allow
the sensor to light off.
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor are
stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is within the
desired range and dewpoint temperature has been met for a sufficient time to allow the sensor to light
off.

Conditions (all active):


3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
The aftertreatment outlet NOx sensor has reached its internal working temperature of 800 degC.
NOx sensor reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond17.3.) for 0.2 seconds
(10.8 V < Aftertreatment outlet NOx sensor battery supply voltage is < 16.5 V) for 0.2 seconds.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.) AND sensor supply power
>= 6 V for 150 seconds

Cummins Inc. Revision Date: March 30, 2017 675


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

521. RefCondRefCond24.57: When NH3 slip is detected, corrective


action is taken. Commanded ANR is decreased by temporarily
stepping down the target SCR conversion efficiency.
When NH3 slip is detected, corrective action is taken. Commanded ANR is decreased by temporarily
stepping down the target SCR conversion efficiency.

Conditions (all active):


Target SCR conversion efficiency correction is started when NH3 Slip Detection module to detect if
NH3 slip is causing a drop in SCR conversion efficiency (See RefCond21.64.) is active. Target SCR
conversion efficiency correction ends: (When Rate of change of Actual SCR Conversion Efficiency
>0%/sec AND Actual SCR Conversion Efficiency>90% ) OR Actual SCR Conversion Efficiency >= Target
SCR Conversion Efficiency OR Target SCR conversion efficiency correction timer >= 60sec.

Cummins Inc. Revision Date: March 30, 2017 676


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

522. RefCondRefCond25.3: Exhaust gas temperature as measured by


the exhaust gas temperature sensor closest to the PM sensor is
above a threshold representing the point at which there is no
longer a concern of condensation on the PM sensor sensing
element.
Exhaust gas temperature as measured by the exhaust gas temperature sensor closest to the PM sensor
is above a threshold representing the point at which there is no longer a concern of condensation on the
PM sensor sensing element.

Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
Engine running condition (See RefCond368.1.) AND the exhaust temperature as measured by the
exhaust gas temperature sensor closest to the PM sensor > 200 degC for 60 seconds.

Cummins Inc. Revision Date: March 30, 2017 677


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

523. RefCondRefCond26.1: Battery voltage is within range.


Battery voltage is within range.

Conditions (all active):


8.5 V < ECM voltage < 17.2 V.

Cummins Inc. Revision Date: March 30, 2017 678


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

524. RefCondRefCond28.9: %O2 reading of Exhaust Air virtual sensor is


valid
%O2 reading of Exhaust Air virtual sensor is valid

Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
Fuel system failure is not present (See RefCond455.2.)

Cummins Inc. Revision Date: March 30, 2017 679


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

525. RefCondRefCond29.2: Urea Quality Sensor (UQS) temperature


sensor element shorted to a high source.
Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element > 4.88 volts OR the temperature
measured at the UQS temperature sensing element > 126 °C) for more than 9 update counts.

Cummins Inc. Revision Date: March 30, 2017 680


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

526. RefCondRefCond30.2: Unknown failure of the UQS concentration


detection element, or UQS Concentration detection element
voltage shorted out of range low.
Unknown failure of the UQS concentration detection element, or UQS Concentration detection element
voltage shorted out of range low.

Conditions (all active):


The voltage measured across the concentration detection element charge pump < 7.5 volts for more
than 8 update counts.

Cummins Inc. Revision Date: March 30, 2017 681


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

527. RefCondRefCond32.3: the disable conditions for the diagnostic are


specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


NOT [The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)]

Cummins Inc. Revision Date: March 30, 2017 682


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

528. RefCondRefCond33.2: Urea Quality Sensor (UQS) temperature


sensing element shorted to a low source.
Urea Quality Sensor (UQS) temperature sensing element shorted to a low source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element < 0.1 volts OR the temperature
measured at the UQS temperature sensing element < -40 °C) for more than 9 update counts.

Cummins Inc. Revision Date: March 30, 2017 683


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

529. RefCondRefCond34.4: the enable conditions for the diagnostic are


specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true

Cummins Inc. Revision Date: March 30, 2017 684


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

530. RefCondRefCond35.2: The Urea Quality Sensor (UQS) is located in


tank.
The Urea Quality Sensor (UQS) is located in tank.

Conditions (all active):


A Urea Quality Sensor (UQS) DEF concentration update has not been received from the sensor within
0 mSec after key-on.

Cummins Inc. Revision Date: March 30, 2017 685


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

531. RefCondRefCond36.2: Urea Quality Sensor (UQS) temperature


sensor element shorted to a low source.
Urea Quality Sensor (UQS) temperature sensor element shorted to a low source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element < 0.047 volts OR the temperature
measured at the UQS temperature sensing element > 115 °C) for more than 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 686


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

532. RefCondRefCond37.2: Urea Quality Sensor (UQS) temperature


sensor element shorted to a high source.
Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element > 1.195 volts OR the temperature
measured at the UQS temperature sensing element < -55 °C) for more than 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 687


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

533. RefCondRefCond39.2: the sensor has completed the DEF type


detection process, and has determined that the fluid in the DEF
tank is not DEF
the sensor has completed the DEF type detection process, and has determined that the fluid in the DEF
tank is not DEF

Conditions (all active):


The concentration type determination is based on measuring the speed of sound in the liquid by
generating an ultrasonic signal that reflects from a fixed reference distance from the sensor. The
sensor has completed the DEF type detection process, and has determined that the fluid in the DEF
tank is not DEF.

Cummins Inc. Revision Date: March 30, 2017 688


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

534. RefCondRefCond40.1: The sensor has completed the DEF type


detection process, and has determined that the fluid in the DEF
tank is not DEF.
The sensor has completed the DEF type detection process, and has determined that the fluid in the DEF
tank is not DEF.

Conditions (all active):


On completion of DEF type detection process, sensor has determined that the fluid in the DEF tank is
other than DEF.

Cummins Inc. Revision Date: March 30, 2017 689


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

535. RefCondRefCond42.2: UQS Concentration detection element


voltage shorted out of range high.
UQS Concentration detection element voltage shorted out of range high.

Conditions (all active):


The voltage measured across the concentration detection element at the diagnostic charge voltage <
0.15 volts for more than 4 update counts.

Cummins Inc. Revision Date: March 30, 2017 690


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

536. RefCondRefCond43.2: UQS Concentration detection element


voltage shorted out of range high.
UQS Concentration detection element voltage shorted out of range high.

Conditions (all active):


The voltage measured at the UQS concentration sensing element > 1.195 volts for more than 5
seconds.

Cummins Inc. Revision Date: March 30, 2017 691


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

537. RefCondRefCond44.2: UQS Concentration detection element


voltage shorted out of range low.
UQS Concentration detection element voltage shorted out of range low.

Conditions (all active):


The voltage measured at the UQS concentration sensing element < 0.047 volts for more than 5
seconds.

Cummins Inc. Revision Date: March 30, 2017 692


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

538. RefCondRefCond52.37: the pause conditions for the diagnostic are


specified as follows
the pause conditions for the diagnostic are specified as follows

Conditions (all active):


Keyswitch transitions to OFF
The in-tank mounted measurement of DEF fluid type is suspect. (See RefCond45.32.)
The in-tank mounted measurement of DEF tank level is suspect. (See RefCond48.18.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is false
The temperature of the fluid in the DEF tank is suspected. (See RefCond51.28.)

Cummins Inc. Revision Date: March 30, 2017 693


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

539. RefCondRefCond58.49: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980
NOT [The in-tank mounted measurement of DEF fluid type is valid. (See RefCond53.35.)] AND NOT
[The in-tank mounted measurement of DEF fluid type is suspect. (See RefCond45.32.)]
NOT [The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)] AND NOT
[The in-tank mounted measurement of DEF tank level is suspect. (See RefCond48.18.)]
System has determined that the DEF tank has been refilled. Detection can occur across key-cycles or
with the engine running and vehicle not moving. (See RefCond54.5.)
The diagnostic has already updated once within the current key-cycle
NOT [there are no DEF low level faults active (See RefCond55.3.)]
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
Conditions stating ambient air temperature is cold (See RefCond373.1.)
NOT [The in-tank mounted measurement of DEF tank level is valid without considering cold ambient
conditions (See RefCond430.3.)]

Cummins Inc. Revision Date: March 30, 2017 694


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

540. RefCondRefCond60.53: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980
Keyswitch transitions to ON
The in-tank mounted measurement of DEF fluid type is valid. (See RefCond53.35.)
The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)
The temperature of the fluid in the DEF tank is within the proper operational range. (See
RefCond59.39.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true
Longer than 300 seconds have elapsed, with keyswitch ON, since the last keyon, or since System has
determined that the DEF tank has been refilled. Detection can occur across key-cycles or with the
engine running and vehicle not moving. (See RefCond54.5.).
The diagnostic has already updated once within the current key-cycle, and subsequently System has
determined that the DEF tank has been refilled. Detection can occur across key-cycles or with the
engine running and vehicle not moving. (See RefCond54.5.).
there are no DEF low level faults active (See RefCond55.3.)
5 seconds have elapsed since 3521.11-SE8690 diagnostics failed.
NOT [Conditions stating ambient air temperature is cold (See RefCond373.1.)]
The in-tank mounted measurement of DEF tank level is valid without considering cold ambient
conditions (See RefCond430.3.)

Cummins Inc. Revision Date: March 30, 2017 695


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

541. RefCondRefCond61.4: SCR Outlet Temperature sensor reading is


suspected and not yet confirmed as faulty.
SCR Outlet Temperature sensor reading is suspected and not yet confirmed as faulty.

Conditions (all active):


SCR Outlet Temperature sensor signal contains invalid data.
(SCR Outlet temperature sensor value is out of range.
)

Cummins Inc. Revision Date: March 30, 2017 696


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

542. RefCondRefCond63.7: OBD Arbitrator allows Quantity and Timing


Diagnostics
OBD Arbitrator allows Quantity and Timing Diagnostics

Conditions (all active):


OBD Arbitrator allows any of the following monitors to run:
651.7-SE3104, 652.7-SE3105, 653.7-SE3102, 654.7-SE3106, 655.7-SE3107, 656.7-SE3108
5394.7-SE7927
4331.18-SE12527, 4331.16-SE12528

Cummins Inc. Revision Date: March 30, 2017 697


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

543. RefCondRefCond64.2: DPF Outlet Temperature sensor reading is


suspected and not yet confirmed as faulty.
DPF Outlet Temperature sensor reading is suspected and not yet confirmed as faulty.

Conditions (all active):


DPF Outlet Temperature sensor signal contains invalid data.
(DPF Outlet temperature sensor value is out of range.
)

Cummins Inc. Revision Date: March 30, 2017 698


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

544. RefCondRefCond65.2: DOC Outlet Temperature sensor reading is


suspected and not yet confirmed as faulty.
DOC Outlet Temperature sensor reading is suspected and not yet confirmed as faulty.

Conditions (all active):


DOC Outlet Temperature sensor signal contains invalid data.
(DOC Outlet temperature sensor value is out of range.
)

Cummins Inc. Revision Date: March 30, 2017 699


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

545. RefCondRefCond66.2: DOC Inlet Temperature sensor reading is


suspected and not yet confirmed as faulty.
DOC Inlet Temperature sensor reading is suspected and not yet confirmed as faulty.

Conditions (all active):


DOC Inlet Temperature sensor signal contains invalid data.
(DOC Inlet temperature sensor value is out of range.
)

Cummins Inc. Revision Date: March 30, 2017 700


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

546. RefCondRefCond67.3: the disable conditions for the diagnostic are


specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


NOT [The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)]

Cummins Inc. Revision Date: March 30, 2017 701


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

547. RefCondRefCond68.4: the enable conditions for the diagnostic are


specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true

Cummins Inc. Revision Date: March 30, 2017 702


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

548. RefCondRefCond69.9: Aftertreatment Inlet NOx sensor reading is


not valid.
Aftertreatment Inlet NOx sensor reading is not valid.

Conditions (all active):


Aftertreatment Inlet NOx sensor reading is not valid. (See RefCond509.2.)

Cummins Inc. Revision Date: March 30, 2017 703


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

549. RefCondRefCond72.4: the disable conditions for the diagnostic are


specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


(The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)) is not active

Cummins Inc. Revision Date: March 30, 2017 704


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

550. RefCondRefCond73.4: the enable conditions for the diagnostic are


specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true

Cummins Inc. Revision Date: March 30, 2017 705


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

551. RefCondRefCond77.48: The DEF Supply Module has begun filling


with DEF
The DEF Supply Module has begun filling with DEF

Conditions (all active):


NOT [Conditions to determine whether Urea Tank is frozen or not. (See RefCond100.19.)]
Key switch is turned ON.
Engine running condition (See RefCond368.1.)
The DEF tank requirements for dosing are satisfied (See RefCond76.7.)
NOT[Conditions to prohibit DEF priming or initiate DEF purging for the system due to low ambient
temperature. (See RefCond99.1.)]
(
Selective Catalyst Reductant (SCR) catalyst bed temperature (calculated as a weighted average of
Diesel Particulate Filter (DPF) outlet and SCR inlet/midbed temperatures) ≥ -80 °C OR SCR Severe
Inducement is active.
)

Cummins Inc. Revision Date: March 30, 2017 706


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

552. RefCondRefCond84.19: Dosing Not Allowed Flag indicating Dosing


command is out of nominal range for Urea Doser Functional
Monitor
Dosing Not Allowed Flag indicating Dosing command is out of nominal range for Urea Doser Functional
Monitor

Conditions (all active):


The calculated intrusive dosing command injection period > 12 sec
OR
The calculated intrusive dosing command injection period < 1 sec
OR
min(injection rate commanded at SCR, injection rate at doser) < 0.145ml/sec when urea doser
functional monitor diagnostic is in abort state.

Cummins Inc. Revision Date: March 30, 2017 707


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

553. RefCondRefCond86.9: Aftertreatment Outlet NOx sensor O2


reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the
sensor's battery supply voltage is within the desired range and
dewpoint temperature has been met for a sufficient time to allow
the sensor to light off.
Aftertreatment Outlet NOx sensor O2 reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is within
the desired range and dewpoint temperature has been met for a sufficient time to allow the sensor to
light off.

Conditions (all active):


3226.4-SE5987, 3226.4-SE5990, 3226.9-SE2488, 3228.2-SE5988
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
The aftertreatment outlet NOx sensor has reached its internal working temperature of 800 degC.
NOx sensor O2 reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond85.2.) for 0 seconds
(10.8 V < Aftertreatment outlet NOx sensor battery supply voltage is < 16.5 V) for 0.2 seconds.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond19.8.) AND sensor supply power
>= 6 V for 150 seconds

Cummins Inc. Revision Date: March 30, 2017 708


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

554. RefCondRefCond87.5: The DEF Supply Module (SM) has completed


pump pressure control and is ready to dose.
The DEF Supply Module (SM) has completed pump pressure control and is ready to dose.

Conditions (all active):


DEF Dosing system is in PRESSURE CONTROL state AND ( 750 kPa(gauge) ≤ DEF supply Pressure ≤
950kPa(gauge)) for 3 seconds
DEF Doser is not in OFF state

Cummins Inc. Revision Date: March 30, 2017 709


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

555. RefCondRefCond88.5: SCR Conversion Efficiency Relay feedback


mode is commanding very high ANR.
SCR Conversion Efficiency Relay feedback mode is commanding very high ANR.

Conditions (all active):


(Target SCR Conversion Efficiency - Actual SCR Conversion Efficiency) > RefTable40.5

Cummins Inc. Revision Date: March 30, 2017 710


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

556. RefCondRefCond89.14: SCR Conversion Efficiency Relay feedback


mode is commanding high dosing for accelerated ammonia
storage in SCR first brick
SCR Conversion Efficiency Relay feedback mode is commanding high dosing for accelerated ammonia
storage in SCR first brick

Conditions (all active):


Actual SCR Conversion Efficiency ≤ 0 %
SCR In temperature ≤ 300°C
Estimated SCR Catalyst Bed temperature ≤ 300°C

Cummins Inc. Revision Date: March 30, 2017 711


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

557. RefCondRefCond91.69: Closed loop control of DEF dosing is


allowed
Closed loop control of DEF dosing is allowed

Conditions (all active):


3226.2-SE7613
3226.21-SE5978
3226.20-SE5976
3226.11-SE11496
3227.20-SE12580
3227.21-SE12581
Conditions are met for SCR dosing (See RefCond16.43.)
Estimated SCR Catalyst bed temperature ≥ 180 °C
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
NOx sensor reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond17.3.)
When NH3 slip is detected, corrective action is taken. Commanded ANR is decreased by temporarily
stepping down the target SCR conversion efficiency. (See RefCond24.57.) is not active
Engine Out NOx measurement sampling window is full (See RefCond90.7.) is not active
NOT[Enable Conditions for DEF dosing command adjustment. (See RefCond469.2.)]

Cummins Inc. Revision Date: March 30, 2017 712


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

558. RefCondRefCond93.11: Aftertreatment Outlet NOx sensor reading


is not valid due to internal control loops within the sensor being
unstable, or active faults detected by the sensor, or the sensor's
battery supply voltage is outside the desired range or dewpoint
temperature not met.
Aftertreatment Outlet NOx sensor reading is not valid due to internal control loops within the sensor
being unstable, or active faults detected by the sensor, or the sensor's battery supply voltage is outside
the desired range or dewpoint temperature not met.

Conditions (all active):


1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
OR
The aftertreatment outlet NOx sensor has not reached its internal working temperature of 800 degC.
OR
3228.2-SE5988 is active
OR
3226.4-SE5990 is active
OR
3226.4-SE5987 is active
OR 3226.9-SE2488 is active
OR
NOx sensor reading is not valid due to internal control loops within the sensor being unstable.. (See
RefCond8.5.)
OR
(Aftertreatment outlet NOx sensor battery supply voltage is < 10.8 V) OR (Aftertreatment outlet NOx
sensor battery supply voltage is > 16.5 V)
OR
Exhaust gas temperature is below a threshold representing that dew point is not reached (See
RefCond3.7.)
OR 3226.10-SE5989 is active
OR
5031.10-SE5051 is not active
OR
5031.10-SE5982 is not active
OR
150 sec has expired after Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. (See RefCond19.8.)
reached

Cummins Inc. Revision Date: March 30, 2017 713


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

559. RefCondRefCond99.1: Conditions to prohibit DEF priming or


initiate DEF purging for the system due to low ambient
temperature.
Conditions to prohibit DEF priming or initiate DEF purging for the system due to low ambient
temperature.

Conditions (all active):


(Ambient Air Temperature< -30 °C) for time ≥ 30 sec
[Ambient Air Temperature status is valid. (See RefCond369.1.)] for time ≥ 30 sec

Cummins Inc. Revision Date: March 30, 2017 714


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

560. RefCondRefCond100.19: Conditions to determine whether Urea


Tank is frozen or not.
Conditions to determine whether Urea Tank is frozen or not.

Conditions (all active):


(
Engine running condition (See RefCond368.1.)
The in-tank mounted measurement of the DEF tank temperature is valid. (See RefCond46.16.)
Urea Tank Temperature is ≤ -30°C
Urea Tank Temperature is > -30°C AND RefTable121.1 time has not elapsed after Engine running
condition (See RefCond368.1.).
(
( Urea Tank Temperature is ≥ -8°C AND The in-tank mounted measurement of the DEF tank
temperature is valid. (See RefCond46.16.) ) For ( 0 sec when Urea Tank temperature has not fallen
below -8 °C in the current key cycle otherwise 1 sec )
Urea Tank Temperature is < -8 °C
OR
5 seconds has elapsed since Key ON when the Tank is in Defrost state AND NOT[The in-tank mounted
measurement of the DEF tank temperature is valid. (See RefCond46.16.)]
)
)
OR
Heating state for Urea lines is in Defrost state

Cummins Inc. Revision Date: March 30, 2017 715


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

561. RefCondRefCond103.79: All common enable condition for control


loop used up is active
All common enable condition for control loop used up is active

Conditions (all active):


Ambient Air Temperature ≥ -6.7 °C
Ambient Air Pressure ≥ 75 kPa(absolute)
The DEF Supply Module (SM) has completed pump pressure control and is ready to dose. (See
RefCond87.5.)
(100 g/sec <= Exhaust gas mass flow rate <= 450 g/sec) For 15 seconds.
Injection rate command >= 0.1 ml/s for 15 seconds.
SCR Catalyst Bed Temperature > 225 °C
SCR Catalyst Bed temperature rate change is <= RefTable38.4 OR (SCR Catalyst Bed temperature rate
of change is < RefTable34.4 for a minimum cumulative time of RefTable220.1 sec. OR (Maximum SCR
Catalyst Bed temperature - Estimated SCR Catalyst Bed temperature) > 100 degC for RefTable221.1
sec.)
Intake NOx reading status is Data Valid.
Aftertreatment Outlet NOx sensor reading is valid since the internal control loops within the sensor
are stable, and no active faults detected by the sensor, and the sensor's battery supply voltage is
within the desired range and dewpoint temperature has been met for a sufficient time to allow the
sensor to light off. (See RefCond20.10.)
Closed loop control of DEF dosing is allowed (See RefCond91.69.)

Cummins Inc. Revision Date: March 30, 2017 716


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

562. RefCondRefCond104.79: SCR Inner loop used up enable conditions


are true.
SCR Inner loop used up enable conditions are true.

Conditions (all active):


(
SCR Conversion Efficiency Relay feedback mode is commanding high dosing for accelerated ammonia
storage in SCR first brick (See RefCond89.14.)
OR
Target SCR conversion efficiency > switching threshold * 0.5
Where
switching threshold =RefTable40.5
)
All common enable condition for control loop used up is active (See RefCond103.79.)

Cummins Inc. Revision Date: March 30, 2017 717


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

563. RefCondRefCond107.49: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980, 3364.10-SE7286, 3521.11-SE8690
NOT [The in-tank mounted measurement of DEF concentration quality is suspect. (See
RefCond105.34.)] AND NOT [The in-tank mounted measurement of DEF concentration quality is valid.
(See RefCond106.40.)]
NOT [The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)] AND NOT
[The in-tank mounted measurement of DEF tank level is suspect. (See RefCond48.18.)]
System has determined that the DEF tank has been refilled. Detection can occur across key-cycles or
with the engine running and vehicle not moving. (See RefCond54.5.)
The diagnostic has already updated once within the current key-cycle
NOT [there are no DEF low level faults active (See RefCond55.3.)]
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
Conditions stating ambient air temperature is cold (See RefCond373.1.)
NOT [The in-tank mounted measurement of DEF tank level is valid without considering cold ambient
conditions (See RefCond430.3.)]

Cummins Inc. Revision Date: March 30, 2017 718


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

564. RefCondRefCond108.37: the pause conditions for the diagnostic


are specified as follows
the pause conditions for the diagnostic are specified as follows

Conditions (all active):


Keyswitch transitions to OFF
The in-tank mounted measurement of DEF concentration quality is suspect. (See RefCond105.34.)
The in-tank mounted measurement of DEF tank level is suspect. (See RefCond48.18.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is false
The temperature of the fluid in the DEF tank is suspected. (See RefCond51.28.)

Cummins Inc. Revision Date: March 30, 2017 719


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

565. RefCondRefCond109.53: The enable conditions for the low


concentration diagnostic are specified as follows
The enable conditions for the low concentration diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980, 3364.10-SE7286, 3521.11-SE8690
Keyswitch transitions to ON
The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)
The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)
The temperature of the fluid in the DEF tank is within the proper operational range. (See
RefCond59.39.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true
Longer than 300 seconds have elapsed, with keyswitch ON, since the last keyon, or since System has
determined that the DEF tank has been refilled. Detection can occur across key-cycles or with the
engine running and vehicle not moving. (See RefCond54.5.).
The diagnostic has already updated once within the current key-cycle, and subsequently System has
determined that the DEF tank has been refilled. Detection can occur across key-cycles or with the
engine running and vehicle not moving. (See RefCond54.5.).
there are no DEF low level faults active (See RefCond55.3.)
5 seconds have elapsed since 3364.18-SE7282 diagnostics failed.
NOT [Conditions stating ambient air temperature is cold (See RefCond373.1.)]
The in-tank mounted measurement of DEF tank level is valid without considering cold ambient
conditions (See RefCond430.3.)

Cummins Inc. Revision Date: March 30, 2017 720


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

566. RefCondRefCond110.56: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


3521.11-SE8690
NOT [The in-tank mounted measurement of DEF concentration quality is suspect. (See
RefCond105.34.)] AND NOT [The in-tank mounted measurement of DEF concentration quality is valid.
(See RefCond106.40.)]
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
NOT [there are no DEF low level faults active (See RefCond55.3.)]
(The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)) is not active
Conditions stating ambient air temperature is cold (See RefCond373.1.)

Cummins Inc. Revision Date: March 30, 2017 721


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

567. RefCondRefCond111.60: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


3521.11-SE8690
The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)
The temperature of the fluid in the DEF tank is within the proper operational range. (See
RefCond59.39.)
there are no DEF low level faults active (See RefCond55.3.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true
NOT [Conditions stating ambient air temperature is cold (See RefCond373.1.)]

Cummins Inc. Revision Date: March 30, 2017 722


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

568. RefCondRefCond113.57: the pause conditions for the diagnostic


are specified as follows
the pause conditions for the diagnostic are specified as follows

Conditions (all active):


The DEF tank temperature or DEF internal temperature <=0 °C OR The in-tank mounted measurement
of Urea Quality Sensor (UQS) temperature is suspect. (See RefCond49.31.)
The in-tank mounted measurement of DEF concentration quality is suspect. (See RefCond105.34.)
the enable conditions for the diagnostic are specified as follows (See RefCond111.60.) is false
the disable conditions for the diagnostic are specified as follows (See RefCond110.56.) is false
The Urea Quality Sensor (UQS) indicates that the fluid type cannot be determined (See
RefCond112.1.)
NOT [The status of in-tank mounted measurement of DEF concentration quality is data error no value.
(See RefCond376.1.)]

Cummins Inc. Revision Date: March 30, 2017 723


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

569. RefCondRefCond114.4: Active errors within the SCR system that


will disable active/intrusive injection of HCs into the exhaust in
order to protect the SCR system
Active errors within the SCR system that will disable active/intrusive injection of HCs into the exhaust in
order to protect the SCR system

Conditions (all active):


4363.0-SE2889
OR
4363.0-SE5293

Cummins Inc. Revision Date: March 30, 2017 724


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

570. RefCondRefCond115.5: Malfunction criteria for the algorithm that


detects an ineffective regeneration of the DPF. (Detection of
ineffective regeneration aborts the current active regeneration of
the DPF.)
Malfunction criteria for the algorithm that detects an ineffective regeneration of the DPF. (Detection of
ineffective regeneration aborts the current active regeneration of the DPF.)

Conditions (all active):


DPF inlet temperature < regeneration target temperature - 50 °C
Rate of active/intrusive injection of hydrocarbons in exhaust ≥ 0.15 g/sec
Sum of the calculated soot oxidation rate and calculated soot NOx-idation rate ≤ 25 g/hr. (NOx-
idation refers to the oxidation of soot from nitric oxides (NO2), which generally occurs at
temperatures between about 250 degC and 400 degC)
Maximum duration of 6,000 seconds. Actual time depends on the manner in which the active
regeneration of the DPF was triggered.

Cummins Inc. Revision Date: March 30, 2017 725


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

571. RefCondRefCond122.2: The fault due to Inhibit Switch timed


regeneration is not active.
The fault due to Inhibit Switch timed regeneration is not active.

Conditions (all active):


3703.31-SE5571

Cummins Inc. Revision Date: March 30, 2017 726


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

572. RefCondRefCond127.12: Urea Doser Functional Response Monitor


is ready to update the fault.
Urea Doser Functional Response Monitor is ready to update the fault.

Conditions (all active):


(Urea Doser Functional Response Monitor has made 2 counts of pass decisions OR Urea Doser
Functional Response Monitor has made 2 counts of fail decisions.)

Cummins Inc. Revision Date: March 30, 2017 727


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

573. RefCondRefCond129.5: SCR Bed temperature reset condition


based on the module off time.
SCR Bed temperature reset condition based on the module off time.

Conditions (all active):


SCR bed temperature ≤ 430 degC

Cummins Inc. Revision Date: March 30, 2017 728


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

574. RefCondRefCond130.22: Exhaust gas temperature is below a


threshold representing that dew point is not reached
Exhaust gas temperature is below a threshold representing that dew point is not reached

Conditions (all active):


(NOT [The exhaust temperature as measured by the sensor closest to the PM sensor is warm. (See
RefCond159.23.)] when PM Sensor is neither in measurement nor in regeneration mode) OR (NOT
[The exhaust temperature as measured by the sensor closest to the PM sensor is warm. (See
RefCond159.23.)] for time greater than 10 sec when PM Sensor is in measurement mode OR in
regeneration mode)
OR Exhaust temperature < 100 degC
OR (NOT [Engine running condition (See RefCond368.1.)] for > [65]sec when PM Sensor is in
measurement mode) OR (NOT [Engine running condition (See RefCond368.1.)] when PM sensor is not
in measurement mode)
OR (SCR out temperature status has timed out OR SCR out temperature status is defaulted)

Cummins Inc. Revision Date: March 30, 2017 729


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

575. RefCondRefCond132.7: Abort condition to disable the diagnostics


when ambient temperature or pressure are outside limit threshold
values.
Abort condition to disable the diagnostics when ambient temperature or pressure are outside limit
threshold values.

Conditions (all active):


Ambient air temperature status is NOT data valid OR Ambient air temperature < -6.7 °C OR Ambient
air pressure status is NOT data valid. OR Ambient air pressure < 75 kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 730


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

576. RefCondRefCond135.2: UQS sensor internal temperature is above


the maximum operating range
UQS sensor internal temperature is above the maximum operating range

Conditions (all active):


(The internal temperature of the UQS > 125 °C) for more than 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 731


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

577. RefCondRefCond136.4: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true

Cummins Inc. Revision Date: March 30, 2017 732


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

578. RefCondRefCond137.3: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


(The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)) is not active

Cummins Inc. Revision Date: March 30, 2017 733


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

579. RefCondRefCond139.16: Enable conditions for the tests run during


motoring.
Enable conditions for the tests run during motoring.

Conditions (all active):


190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
651.5-SE916, 652.5-SE917, 653.5-SE918, 654.5-SE919, 655.5-SE920, 656.5-SE921
5571.0-SE914
157.3-SE525, 157.4-SE526
633.31-SE518
157.16-SE522
157.18-SE523
1347.3-SE965, 1347.4-SE966
1347.2-SE915
OBD Arbitrator allows Quantity and Timing Diagnostics (See RefCond63.7.)
Engine Speed > 850 RPM
The accumulated consecutive time that the total fueling command < 0.01 mg/stroke is less than 3 sec.
Engine is in WARM State.
Engine is in RUN State OR engine is in BRAKING State.
Engine is operating in any of the following thermal management modes:
Base mode (not in DENOX, DESOOT, DESOX, DESORB).
SCR Thermal Management mode (more information available in AECD 13-2).

Cummins Inc. Revision Date: March 30, 2017 734


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

580. RefCondRefCond143.3: VGT driver failure


VGT driver failure

Conditions (all active):


641.11-SE1627, 641.12-SE1604, 641.14-SE1605, 641.7-SE1606

Cummins Inc. Revision Date: March 30, 2017 735


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

581. RefCondRefCond144.4: The VGT Position is not known to be good.


The VGT Position is not known to be good.

Conditions (all active):


641.9-SE8054
OR
Any Active: 641.7-SE1606

Cummins Inc. Revision Date: March 30, 2017 736


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

582. RefCondRefCond145.4: The Intake Air Throttle Valve Position is not


known to be good.
The Intake Air Throttle Valve Position is not known to be good.

Conditions (all active):


51.3-SE3530, 51.4-SE3529

Cummins Inc. Revision Date: March 30, 2017 737


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

583. RefCondRefCond146.5: The EGR H-bridge valve position is not


valid.
The EGR H-bridge valve position is not valid.

Conditions (all active):


27.3-SE3202, 27.4-SE3203, 2791.13-SE3980

Cummins Inc. Revision Date: March 30, 2017 738


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

584. RefCondRefCond148.4: No Active Ambient Air Temperature


System Errors
No Active Ambient Air Temperature System Errors

Conditions (all active):


171.2-SE3799, 171.3-SE3802, 171.4-SE3803

Cummins Inc. Revision Date: March 30, 2017 739


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

585. RefCondRefCond149.5: Any Active Air Temperature System Errors


Any Active Air Temperature System Errors

Conditions (all active):


171.2-SE3799, 171.3-SE3802, 171.4-SE3803

Cummins Inc. Revision Date: March 30, 2017 740


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

586. RefCondRefCond152.51: Conditions that enable the calculation of


conversion efficiency of an oxidation catalyst.
Conditions that enable the calculation of conversion efficiency of an oxidation catalyst.

Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
190.11-SE460, 190.2-SE417, 190.2-SE419, 190.2-SE54, 723.2-SE415, 723.2-SE422, 723.2-SE45, 723.7-
SE389
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732,
4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
DOC inlet temperature > 235 °C
Catalyst intake temperature 1 > 200 °C
Exhaust flow < 375 g/sec
Rate of active/intrusive injection of hydrocarbons in exhaust > 0.14 g/sec
Active/intrusive injection of hydrocarbons in exhaust is > 0.14 g/s for at least 120 continuous sec,
within the current drive cycle.
Exhaust flow > 50 g/sec
( A new active regeneration of the DPF is initiated.
OR Active regeneration restarted at key-on if regeneration in process during last key cycle but not
completed.
OR Active DPF regeneration is in process.
)

Cummins Inc. Revision Date: March 30, 2017 741


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

587. RefCondRefCond154.22: Conditions that pause the calculation of


conversion efficiency of an oxidation catalyst.
Conditions that pause the calculation of conversion efficiency of an oxidation catalyst.

Conditions (all active):


Time, within a single regeneration event, after active/intrusive injection of hydrocarbons into exhaust
is stopped is > 60 sec
OR
DOC inlet temperature ≤ 235 °C
OR
First Catalyst intake temperature ≤ 200 °C
OR
Exhaust flow ≥ 375 g/sec
OR
Rate of active/intrusive injection of hydrocarbons in exhaust ≤ 0.14 g/sec
OR
Time in which active/intrusive injection of hydrocarbons in exhaust is above 0.14 g/sec for < 120 sec
OR
Exhaust flow ≤ 50 g/sec
OR
(DOC out temperature - First Catalyst intake temperature) < 50 °C

Cummins Inc. Revision Date: March 30, 2017 742


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

588. RefCondRefCond156.4: The system detects that the DPF is no


longer new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a
false high estimation of soot load.
The system detects that the DPF is no longer new, or "green". New DPF temporarily exhibits high
backpressure during their first hours of use which can lead to a false high estimation of soot load.

Conditions (all active):


Regeneration of DPF is completed at least once OR engine speed > 1,000 RPM for 60 sec

Cummins Inc. Revision Date: March 30, 2017 743


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

589. RefCondRefCond157.4: The system considers that the DPF is new,


or "green". New DPF temporarily exhibits high backpressure during
their first hours of use which can lead to a false high estimation of
soot load.
The system considers that the DPF is new, or "green". New DPF temporarily exhibits high backpressure
during their first hours of use which can lead to a false high estimation of soot load.

Conditions (all active):


Regeneration of DPF has not been completed over the life of the DPF.
Over the life of the DPF, engine speed has not been > 1,000 rpm for 60 seconds.

Cummins Inc. Revision Date: March 30, 2017 744


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

590. RefCondRefCond159.23: The exhaust temperature as measured by


the sensor closest to the PM sensor is warm.
The exhaust temperature as measured by the sensor closest to the PM sensor is warm.

Conditions (all active):


The exhaust temperature as measured by the sensor closest to the PM sensor > 200 degC FOR
RefTable73.1 sec. Where: Processed Ambient Air temperature = Ambient Air temperature when
(Ambient air temperature is data valid. (See RefCond198.2.)) else Processed Ambient Air temperature
= -10 degC. And processed exhaust temperature is calculated as: The minimum exhaust temperature
captured after the rising event of (Exhaust temperature < 100 degC AND Engine running condition
(See RefCond368.1.) AND exhaust temperature status at sensor closest to the PM sensor is NOT data
valid).

Cummins Inc. Revision Date: March 30, 2017 745


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

591. RefCondRefCond160.23: Exhaust gas temperature is above a


threshold representing the point at which there is no longer a
concern of condensation on the PM sensor element.
Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the PM sensor element.

Conditions (all active):


The exhaust temperature as measured by the sensor closest to the PM sensor is warm. (See
RefCond159.23.)
Exhaust temperature > 100 degC
NOT [PM sensor hot start delay logic is allowed to run. (See RefCond131.2.)]
Engine running condition (See RefCond368.1.)
(SCR out temperature status is not timed out AND SCR out temperature status is not defaulted) OR
[SCR Out temperature sensor reading no value and not yet confirmed as faulty. (See RefCond420.1.)]

Cummins Inc. Revision Date: March 30, 2017 746


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

592. RefCondRefCond167.8: Aftertreatment Outlet NOx sensor reading


is not valid due to internal control loops within the sensor being
unstable, or active faults detected by the sensor, or the sensor's
battery supply voltage is outside the desired range or dewpoint
temperature not met.
Aftertreatment Outlet NOx sensor reading is not valid due to internal control loops within the sensor
being unstable, or active faults detected by the sensor, or the sensor's battery supply voltage is outside
the desired range or dewpoint temperature not met.

Conditions (all active):


3226.9-SE2488
OR
The aftertreatment outlet NOx sensor has not reached its internal working temperature of 800 degC.
OR
150 sec has not expired after Exhaust gas temperature is above a threshold representing the point at
which there is no longer a concern of condensation on the NOx sensor element. (See RefCond19.8.)
reached
OR
NOx sensor reading is valid since the internal control loops within the sensor have stabilized. (See
RefCond17.3.) for < 0.2 seconds
OR
(Aftertreatment outlet NOx sensor battery supply voltage is < 10.8 V) OR (Aftertreatment outlet NOx
sensor battery supply voltage is > 16.5 V)

Cummins Inc. Revision Date: March 30, 2017 747


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

593. RefCondRefCond168.1: Enable conditions for the algorithm that


detects an ineffective regeneration of the DPF.
Enable conditions for the algorithm that detects an ineffective regeneration of the DPF.

Conditions (all active):


Active regeneration of the DPF is occurring.

Cummins Inc. Revision Date: March 30, 2017 748


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

594. RefCondRefCond169.1: Abort conditions for the algorithm that


detects an ineffective regeneration of the DPF.
Abort conditions for the algorithm that detects an ineffective regeneration of the DPF.

Conditions (all active):


Active regeneration of the diesel particulate filter is not occurring.

Cummins Inc. Revision Date: March 30, 2017 749


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

595. RefCondRefCond170.5: Pause conditions for the algorithm that


detects an ineffective regeneration of the DPF.
Pause conditions for the algorithm that detects an ineffective regeneration of the DPF.

Conditions (all active):


DPF inlet temperature ≥ regeneration target temperature - 50 °C
OR
Rate of active/intrusive injection of hydrocarbons in exhaust < 0.15 g/sec
OR
Sum of calculated soot oxidation rate and calculated soot NOx-idation rate > 25 g/hr (NOx-idation is
oxidation of soot from nitric oxides (NO2) which generally occurs at temperatures between about 250
degC and 400 degC.)

Cummins Inc. Revision Date: March 30, 2017 750


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

596. RefCondRefCond171.1: Average of three exhaust gas temperatures


is less than a calibratable threshold OR ECM Off Time is data valid
and greater than a calibratable threshold
Average of three exhaust gas temperatures is less than a calibratable threshold OR ECM Off Time is data
valid and greater than a calibratable threshold

Conditions (all active):


Average of three exhaust gas temperatures < 100 °C.
SCR out temperature status is data valid.
DOC outlet temperature status is data valid.
DPF outlet temperature status is data valid.

Cummins Inc. Revision Date: March 30, 2017 751


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

597. RefCondRefCond172.5: SCR Bed temperature reset condition


based on the module off time.
SCR Bed temperature reset condition based on the module off time.

Conditions (all active):


SCR bed temperature > 430 degC

Cummins Inc. Revision Date: March 30, 2017 752


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

598. RefCondRefCond174.3: A block heater is not detected.


A block heater is not detected.

Conditions (all active):


The temperature drop detected on Coolant Temperature Sensor ≤ 1.2 °C for a time period of 30
seconds after the engine is started up.

Cummins Inc. Revision Date: March 30, 2017 753


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

599. RefCondRefCond176.4: Slow Actuator Response: The engine


conditions must be appropriate to avoid a false detect of a stuck
actuator.
Slow Actuator Response: The engine conditions must be appropriate to avoid a false detect of a stuck
actuator.

Conditions (all active):


The Engine is Running.
ONE of the two following conditions is TRUE:
Retarder is engaged OR vehicle speed has NOT been >= 3.107 mph OR vehicle speed has been >=
3.107 mph for more than 300 seconds.
OR
( |Commanded Charge Flow - Measured Charge Flow| > 10 kg/min AND the ratio |Commanded
Charge Flow - Measured Charge Flow|/Commanded Charge flow >= 10 % ) for > 3 seconds.

Cummins Inc. Revision Date: March 30, 2017 754


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

600. RefCondRefCond177.5: Slow Actuator Response: The


turbocharger smart device has detected that it cannot meet its
commanded position within an acceptable time.
Slow Actuator Response: The turbocharger smart device has detected that it cannot meet its
commanded position within an acceptable time.

Conditions (all active):


|turbocharger smart device's received commanded position - turbocharger smart device internally
measured position| > 9.3 % for 1.5 msec.

Cummins Inc. Revision Date: March 30, 2017 755


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

601. RefCondRefCond179.1: Message Timeout: The turbocharger smart


device has not received a position command message for greater
than or equal to a calibrated time after previously having received
a command message.
Message Timeout: The turbocharger smart device has not received a position command message for
greater than or equal to a calibrated time after previously having received a command message.

Conditions (all active):


Message Timeout: The turbocharger smart device actuator has not received a command message
from the controlling ECM for 4.075 seconds after previously having received a command message.

Cummins Inc. Revision Date: March 30, 2017 756


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

602. RefCondRefCond180.1: No Source: The turbocharger smart device


has not received a message from the ECM.
No Source: The turbocharger smart device has not received a message from the ECM.

Conditions (all active):


No Source: The turbocharger smart device has never received a message from the ECM for > 12
seconds.

Cummins Inc. Revision Date: March 30, 2017 757


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

603. RefCondRefCond182.1: The turbocharger smart device has


detected an internal error which will prevent it from functioning
normally.
The turbocharger smart device has detected an internal error which will prevent it from functioning
normally.

Conditions (all active):


The turbocharger smart device detects any of the conditions:
Invalid Hall Effect sensor state or sequence. Three Hall Effect sensors are used, and are expected to
move within a known series of valid sequences. Valid Hall Effect sensors may not report HHH or LLL
(all high or all low). If either the state or the sequence is invalid, the error condition is active
OR
The measured motor current indicates a short circuit condition within driver circuit.
OR
Invalid position calibration data detected during the turbocharger smart device initialization.
OR
Microprocessor internal error - the turbocharger smart device has detected an internal error such as
an invalid ROM checksum, Watchdog Reset, or other similar error relating to a failed CPU or module.

Cummins Inc. Revision Date: March 30, 2017 758


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

604. RefCondRefCond184.1: The turbocharger smart device has not


detected a physical stop during the powerup process.
The turbocharger smart device has not detected a physical stop during the powerup process.

Conditions (all active):


The turbocharger smart device detected a motor movement of > 239.5 degrees without detecting the
physical travel limits.
OR
The turbocharger smart device detected a calibrated span of < 30 degrees or span of > 200 degrees.

Cummins Inc. Revision Date: March 30, 2017 759


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

605. RefCondRefCond187.1: The voltage for the turbocharger smart


device is less than a calibrated value.
The voltage for the turbocharger smart device is less than a calibrated value.

Conditions (all active):


The turbocharger smart device voltage is < 9 V for > 10 seconds.

Cummins Inc. Revision Date: March 30, 2017 760


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

606. RefCondRefCond188.4: Estimated aftertreatment inlet gas


temperature is valid.
Estimated aftertreatment inlet gas temperature is valid.

Conditions (all active):


3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 4765.2-SE13173, 4765.2-SE13176, 4765.2-SE2858,
4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-SE12508

Cummins Inc. Revision Date: March 30, 2017 761


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

607. RefCondRefCond194.3: SCR conversion efficiency variation term


settles down.
SCR conversion efficiency variation term settles down.

Conditions (all active):


Time elapsed after key switch ON ≥ 0 sec

Cummins Inc. Revision Date: March 30, 2017 762


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

608. RefCondRefCond197.18: Condition to abort the diagnostic based


on the value of battery voltage and engine cranking state
Condition to abort the diagnostic based on the value of battery voltage and engine cranking state

Conditions (all active):


( Engine is in Cranking state OR ( ECM battery voltage status is Data Valid AND (ECM battery voltage >
17.2 V OR ECM battery voltage < 8.5 V) ) OR 168.17-SE296 is set OR 168.15-SE297 is set. ) OR ( 3 sec
has not elapsed since (Engine is not in Cranking state AND (ECM battery voltage status is Data Valid
AND 17.2 V > ECM battery voltage > 8.5 V) AND 168.17-SE296 is not set AND 168.15-SE297 is not
set.) )
OR
(
(
Key Switch is ON
Engine state is Engine Stopped.
NOT[Engine running condition (See RefCond368.1.)]
ECM battery voltage ≤ 10 V
)
OR
Battery voltage ≤ 10 V was detected during Engine Stopped condition AND ( (Calibratable amount of
time has not elapsed since Engine running condition (See RefCond368.1.) AND battery voltage is ≥ 11
V) OR Sensor Control Unit (SCU) Errors are present )
)

Cummins Inc. Revision Date: March 30, 2017 763


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

609. RefCondRefCond198.2: Ambient air temperature is data valid.


Ambient air temperature is data valid.

Conditions (all active):


171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803

Cummins Inc. Revision Date: March 30, 2017 764


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

610. RefCondRefCond200.1: PM sensor is in measurement mode for


too long, with out making a diagnostic increment or decrement
decision.
PM sensor is in measurement mode for too long, with out making a diagnostic increment or decrement
decision.

Conditions (all active):


PM sensor is in measurement mode FOR ≥ 3,600 sec, without making a diagnostic increment OR
decrement decision.

Cummins Inc. Revision Date: March 30, 2017 765


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

611. RefCondRefCond201.5: Exhaust flow and temperature conditions


are favorable for a succesful PM sensor regeneration.
Exhaust flow and temperature conditions are favorable for a succesful PM sensor regeneration.

Conditions (all active):


Exhaust flow velocity status is data valid.
Exhaust temperature status at sensor closest to the PM sensor is data valid.
Exhaust temperature and flow check is TRUE FOR ≥ 60 sec. Where Exhaust temperature and flow
check is TRUE when the value in RefTable197.1 is ≥ 1 (unitless).

Cummins Inc. Revision Date: March 30, 2017 766


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

612. RefCondRefCond203.1: PM sensor has reactivated and exited


measurement mode greater than or equal to a calibratable
number of occurance counts prior to making a decision in the
current drive cycle.
PM sensor has reactivated and exited measurement mode greater than or equal to a calibratable
number of occurance counts prior to making a decision in the current drive cycle.

Conditions (all active):


PM sensor has reactivated and exited measurement mode ≥ 10 counts in the current drive cycle.

Cummins Inc. Revision Date: March 30, 2017 767


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

613. RefCondRefCond204.3: PM sensor probe temperature and exhaust


temperature at sensor closest to the PM sensor should be within a
range for the sensor measurement to be enabled.
PM sensor probe temperature and exhaust temperature at sensor closest to the PM sensor should be
within a range for the sensor measurement to be enabled.

Conditions (all active):


PM sensor probe temperature sensor status is data valid.
PM sensor probe temperature > 79 degC FOR ≥ 30 sec.
PM sensor is NOT performing a regeneration AND PM sensor probe temperature < 400 degC FOR ≥ 10
sec.
Exhaust temperature at sensor closest to the PM sensor < 450 degC FOR ≥ 20 sec.
Exhaust temperature at sensor closest to the PM sensor > 60 degC FOR ≥ 60 sec.
Exhaust temperature status at sensor closest to the PM sensor is data valid.

Cummins Inc. Revision Date: March 30, 2017 768


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

614. RefCondRefCond225.1: DEF tank temperature sensor element


shorted to a high source.
DEF tank temperature sensor element shorted to a high source.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element > 4.88 volts OR the measured
DEF tank temperature >
126 °C) for more than 9 update counts.

Cummins Inc. Revision Date: March 30, 2017 769


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

615. RefCondRefCond226.1: DEF tank temperature sensor element


shorted to a low source.
DEF tank temperature sensor element shorted to a low source.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element < 0.1 volts OR the measured
DEF tank temperature <
-40 °C) for more than 9 update counts.

Cummins Inc. Revision Date: March 30, 2017 770


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

616. RefCondRefCond227.2: DEF tank temperature sensor element


shorted to a high source or open circuit.
DEF tank temperature sensor element shorted to a high source or open circuit.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element > 1.2 volts) for more than 5
seconds.

Cummins Inc. Revision Date: March 30, 2017 771


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

617. RefCondRefCond229.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)

Cummins Inc. Revision Date: March 30, 2017 772


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

618. RefCondRefCond230.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
NOT [the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)]

Cummins Inc. Revision Date: March 30, 2017 773


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

619. RefCondRefCond231.2: DEF tank temperature sensor element


shorted to a low source.
DEF tank temperature sensor element shorted to a low source.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element < 0.046 volts) for more than 5
seconds.

Cummins Inc. Revision Date: March 30, 2017 774


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

620. RefCondRefCond232.1: The engine is cold soaked


The engine is cold soaked

Conditions (all active):


Engine Control Module off time > 28,800 sec

Cummins Inc. Revision Date: March 30, 2017 775


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

621. RefCondRefCond237.6: Urea Doser Functional Response Monitor


updates the fault and Urea Doser Functional Response Monitor
System Error is not active
Urea Doser Functional Response Monitor updates the fault and Urea Doser Functional Response
Monitor System Error is not active

Conditions (all active):


5394.7-SE7927
Urea Doser Functional Response Monitor is ready to update the fault. (See RefCond127.12.)

Cummins Inc. Revision Date: March 30, 2017 776


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

622. RefCondRefCond249.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
NOT [the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)]

Cummins Inc. Revision Date: March 30, 2017 777


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

623. RefCondRefCond250.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)

Cummins Inc. Revision Date: March 30, 2017 778


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

624. RefCondRefCond251.2: Conditions stating ambient air


temperature is cold
Conditions stating ambient air temperature is cold

Conditions (all active):


1761.1-SE2906, 1761.1-SE4189, 1761.10-SE8684, 1761.17-SE2907, 1761.18-SE4188, 4096.31-SE5279
Ambient air temperature <= -20 °C
Ambient air temperature status is Valid.

Cummins Inc. Revision Date: March 30, 2017 779


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

625. RefCondRefCond252.2: DEF level detection element voltage


shorted to a low source.
DEF level detection element voltage shorted to a low source.

Conditions (all active):


(The voltage measured at the DEF tank level sensing element < 0.05 volts OR the measured DEF tank
level > 284 mm OR the resistance across the DEF tank level sensing element < 33 ohm) for more than
5 seconds.

Cummins Inc. Revision Date: March 30, 2017 780


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

626. RefCondRefCond253.2: DEF level detection element voltage


shorted to a high source or open circuit.
DEF level detection element voltage shorted to a high source or open circuit.

Conditions (all active):


(The voltage measured at the DEF tank level sensing element > 2.95 volts OR the measured DEF tank
level < 52 mm OR the resistance across the DEF tank level sensing element > 3,875 ohm) for more
than 5 seconds.

Cummins Inc. Revision Date: March 30, 2017 781


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

627. RefCondRefCond254.1: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


Key Switch is ON for 6 sec

Cummins Inc. Revision Date: March 30, 2017 782


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

628. RefCondRefCond256.4: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)

Cummins Inc. Revision Date: March 30, 2017 783


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

629. RefCondRefCond257.1: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


Key Switch is OFF.

Cummins Inc. Revision Date: March 30, 2017 784


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

630. RefCondRefCond258.4: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
NOT [the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)]

Cummins Inc. Revision Date: March 30, 2017 785


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

631. RefCondRefCond259.2: DEF level detection element voltage


shorted out of range high.
DEF level detection element voltage shorted out of range high.

Conditions (all active):


The voltage measured across the DEF level detection element at the diagnostic charge voltage > 0.15
volts for more than 4 update counts.

Cummins Inc. Revision Date: March 30, 2017 786


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

632. RefCondRefCond260.1: Unknown failure of the DEF level detection


element, or DEF level detection element shorted out of range low.
Unknown failure of the DEF level detection element, or DEF level detection element shorted out of
range low.

Conditions (all active):


The voltage measured across the DEF level detection charge pump at the diagnostic charge voltage <
7.5 volts for more than 8 update counts.

Cummins Inc. Revision Date: March 30, 2017 787


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

633. RefCondRefCond261.22: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568
The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)
The in-tank mounted measurement of the DEF tank temperature is valid. (See RefCond46.16.)
the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)
DEF tank temperature > 0 °C
there are no DEF low level faults active (See RefCond55.3.)
NOT [Conditions stating ambient air temperature is cold (See RefCond251.2.)]

Cummins Inc. Revision Date: March 30, 2017 788


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

634. RefCondRefCond262.22: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568
NOT [The in-tank mounted measurement of DEF tank level is suspect. (See RefCond48.18.)]
NOT [The in-tank mounted measurement of DEF tank level is valid. (See RefCond47.22.)]
NOT [The in-tank mounted measurement of the DEF tank temperature is suspect. (See
RefCond50.15.)]
NOT [The in-tank mounted measurement of the DEF tank temperature is valid. (See RefCond46.16.)]
NOT [the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)]
DEF tank temperature < -5 °C
NOT [there are no DEF low level faults active (See RefCond55.3.)]
Conditions stating ambient air temperature is cold (See RefCond251.2.)

Cummins Inc. Revision Date: March 30, 2017 789


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

635. RefCondRefCond263.22: the pause conditions for the diagnostic


are specified as follows
the pause conditions for the diagnostic are specified as follows

Conditions (all active):


DEF tank temperature ≤ 0 °C OR The in-tank mounted measurement of DEF tank level is suspect. (See
RefCond48.18.) OR The in-tank mounted measurement of the DEF tank temperature is suspect. (See
RefCond50.15.).
NOT [the enable conditions for the diagnostic are specified as follows (See RefCond261.22.)]
NOT [the disable conditions for the diagnostic are specified as follows (See RefCond262.22.)]

Cummins Inc. Revision Date: March 30, 2017 790


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

636. RefCondRefCond267.1: Fluid level in the DEF tank as measured by


the DEF tank level sensor is below the Empty Calibration set point.
Fluid level in the DEF tank as measured by the DEF tank level sensor is below the Empty Calibration set
point.

Conditions (all active):


1761.1-SE2906

Cummins Inc. Revision Date: March 30, 2017 791


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

637. RefCondRefCond307.2: The turbocharger smart device has


detected a warm temperature condition.
The turbocharger smart device has detected a warm temperature condition.

Conditions (all active):


The turbocharger smart device actuator has detected a temperature in excess of 150 deg C.

Cummins Inc. Revision Date: March 30, 2017 792


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

638. RefCondRefCond308.1: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


Key Switch is ON for 6 sec

Cummins Inc. Revision Date: March 30, 2017 793


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

639. RefCondRefCond309.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)

Cummins Inc. Revision Date: March 30, 2017 794


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

640. RefCondRefCond310.1: The disable conditions for the diagnostic


are specified as follows.
The disable conditions for the diagnostic are specified as follows.

Conditions (all active):


Key Switch is OFF.

Cummins Inc. Revision Date: March 30, 2017 795


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

641. RefCondRefCond311.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
NOT [the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)]

Cummins Inc. Revision Date: March 30, 2017 796


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

642. RefCondRefCond312.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)

Cummins Inc. Revision Date: March 30, 2017 797


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

643. RefCondRefCond313.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


1761.13-SE8568, 1761.9-SE7665
NOT [the in-tank mounted DEF tank level sensor detected as active (See RefCond255.2.)]

Cummins Inc. Revision Date: March 30, 2017 798


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

644. RefCondRefCond315.18: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


110.3-SE75, 110.4-SE76
105.2-SE3793, 105.3-SE487, 105.4-SE488
The engine is cold soaked (See RefCond232.1.)
A block heater is not detected. (See RefCond174.3.)
The diagnostic has not previously completed during this key cycle
time elapsed since keyon > 45 sec
The in-tank mounted measurement of Urea Quality Sensor (UQS) temperature is valid. (See
RefCond56.32.)

Cummins Inc. Revision Date: March 30, 2017 799


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

645. RefCondRefCond316.24: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


105.2-SE3793, 105.3-SE487, 105.4-SE488, 110.3-SE75, 110.4-SE76
OR
A block heater is detected. (See RefCond294.3.)
OR
NOT [The in-tank mounted measurement of Urea Quality Sensor (UQS) temperature is suspect. (See
RefCond49.31.)] AND NOT [The in-tank mounted measurement of Urea Quality Sensor (UQS)
temperature is valid. (See RefCond56.32.)]

Cummins Inc. Revision Date: March 30, 2017 800


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

646. RefCondRefCond317.28: The enable conditions for the diagnostic


are specified as follows
The enable conditions for the diagnostic are specified as follows

Conditions (all active):


3521.31-SE13410
3362.31-SE6980
The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.)
Keyswitch transitions to ON AND Diagnostic has not made a decision.
The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)
Ambient Air Temperature > -6.7°C
DOC Inlet Temperature sensor data has no value.

Cummins Inc. Revision Date: March 30, 2017 801


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

647. RefCondRefCond318.32: The disable conditions for the diagnostic


are specified as follows
The disable conditions for the diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980, 3521.31-SE13410
OR
NOT [The in-tank mounted measurement of DEF concentration quality is suspect. (See
RefCond105.34.)]
OR
NOT [The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)]
OR
Keyswitch is ON for time < 300 seconds
OR
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
OR
Ambient Air Temperature ≤ -6.7°C

Cummins Inc. Revision Date: March 30, 2017 802


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

648. RefCondRefCond319.27: The disable conditions for the diagnostic


are specified as follows
The disable conditions for the diagnostic are specified as follows

Conditions (all active):


NOT [The in-tank mounted measurement of DEF concentration quality is suspect. (See
RefCond105.34.)]
OR
NOT [The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)]
OR
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
OR
NOT[The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)]
OR
Ambient Air Temperature ≤ -6.7°C

Cummins Inc. Revision Date: March 30, 2017 803


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

649. RefCondRefCond320.33: The enable conditions for the diagnostic


are specified as follows
The enable conditions for the diagnostic are specified as follows

Conditions (all active):


The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.)
The temperature of the fluid in the DEF tank is within the proper operational range. (See
RefCond59.39.)
The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)
Ambient Air Temperature > -6.7°C

Cummins Inc. Revision Date: March 30, 2017 804


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

650. RefCondRefCond321.28: The disable conditions for the diagnostic


are specified as follows
The disable conditions for the diagnostic are specified as follows

Conditions (all active):


3362.31-SE6980, 3521.31-SE13410
OR
NOT [The in-tank mounted measurement of DEF concentration quality is suspect. (See
RefCond105.34.)]
OR
NOT [The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)]
OR
Keyswitch is ON for time < 300 seconds
OR
The temperature of the fluid in the DEF tank is not within the proper operational range (See
RefCond57.36.)
OR
Ambient Air Temperature ≤ -6.7°C

Cummins Inc. Revision Date: March 30, 2017 805


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

651. RefCondRefCond322.28: The enable conditions for the diagnostic


are specified as follows
The enable conditions for the diagnostic are specified as follows

Conditions (all active):


3521.31-SE13410
3362.31-SE6980
The Urea Quality Sensor (UQS) is located in tank. (See RefCond35.2.)
Keyswitch transitions to ON
The in-tank mounted measurement of DEF concentration quality is valid. (See RefCond106.40.)
Ambient Air Temperature > -6.7°C
DOC Inlet Temperature sensor data has no value.

Cummins Inc. Revision Date: March 30, 2017 806


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

652. RefCondRefCond368.1: Engine running condition


Engine running condition

Conditions (all active):


Engine is Running

Cummins Inc. Revision Date: March 30, 2017 807


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

653. RefCondRefCond369.1: Ambient Air Temperature status is valid.


Ambient Air Temperature status is valid.

Conditions (all active):


171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803

Cummins Inc. Revision Date: March 30, 2017 808


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

654. RefCondRefCond370.1: Urea Quality Sensor (UQS) temperature


sensor element shorted to a high source.
Urea Quality Sensor (UQS) temperature sensor element shorted to a high source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element > 4.87 volts OR the temperature
measured at the UQS temperature sensing element < -55 °C) for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 809


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

655. RefCondRefCond371.1: UQS Concentration detection element


voltage shorted out of range low.
UQS Concentration detection element voltage shorted out of range low.

Conditions (all active):


The voltage measured at the UQS concentration sensing element < 0 volts for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 810


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

656. RefCondRefCond372.1: UQS Concentration detection element


voltage shorted out of range high.
UQS Concentration detection element voltage shorted out of range high.

Conditions (all active):


The voltage measured at the UQS concentration sensing element > 4.96 volts for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 811


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

657. RefCondRefCond373.1: Conditions stating ambient air


temperature is cold
Conditions stating ambient air temperature is cold

Conditions (all active):


Ambient air temperature <= -20 °C

Cummins Inc. Revision Date: March 30, 2017 812


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

658. RefCondRefCond374.1: Urea Quality Sensor (UQS) temperature


sensor element shorted to a low source.
Urea Quality Sensor (UQS) temperature sensor element shorted to a low source.

Conditions (all active):


(The voltage measured at the UQS temperature sensing element < 0.49 volts OR the temperature
measured at the UQS temperature sensing element > 115 °C) for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 813


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

659. RefCondRefCond376.1: The status of in-tank mounted


measurement of DEF concentration quality is data error no value.
The status of in-tank mounted measurement of DEF concentration quality is data error no value.

Conditions (all active):


3364.9-SE6447
(
Keyswitch is OFF
OR
Engine is in cranking state
OR
(NOT [The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)] AND
Urea concentration message status sent by datalink is not valid)
)

Cummins Inc. Revision Date: March 30, 2017 814


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

660. RefCondRefCond381.2: DOC Inlet temperature sensor data is not


available and not yet confirmed as faulty.
DOC Inlet temperature sensor data is not available and not yet confirmed as faulty.

Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DOC Inlet Temperature sensor data is not available.

Cummins Inc. Revision Date: March 30, 2017 815


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

661. RefCondRefCond382.2: DOC Inlet temperature sensor have no


value and not yet confirmed as faulty.
DOC Inlet temperature sensor have no value and not yet confirmed as faulty.

Conditions (all active):


4765.3-SE6729, 4765.3-SE6735, 4765.4-SE6730, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DOC Intlet Temperature sensor data has no value.

Cummins Inc. Revision Date: March 30, 2017 816


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

662. RefCondRefCond383.2: DOC Outlet temperature sensor data is not


available and not yet confirmed as faulty.
DOC Outlet temperature sensor data is not available and not yet confirmed as faulty.

Conditions (all active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DOC Outlet Temperature sensor data is not available.

Cummins Inc. Revision Date: March 30, 2017 817


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

663. RefCondRefCond384.2: DOC Outlet temperature sensor have no


value and not yet confirmed as faulty.
DOC Outlet temperature sensor have no value and not yet confirmed as faulty.

Conditions (all active):


3242.3-SE6731, 3242.3-SE6736, 3242.4-SE6732, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DOC Outlet Temperature sensor data has no value.

Cummins Inc. Revision Date: March 30, 2017 818


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

664. RefCondRefCond385.2: DPF Outlet temperature sensor data is not


available and not yet confirmed as faulty.
DPF Outlet temperature sensor data is not available and not yet confirmed as faulty.

Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DPF Outlet Temperature sensor data is not available.

Cummins Inc. Revision Date: March 30, 2017 819


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

665. RefCondRefCond386.2: DPF Outlet temperature sensor have no


value and not yet confirmed as faulty.
DPF Outlet temperature sensor have no value and not yet confirmed as faulty.

Conditions (all active):


3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-SE6722,
5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728
DPF Outlet Temperature sensor data has no value.

Cummins Inc. Revision Date: March 30, 2017 820


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

666. RefCondRefCond412.1: Ambient air temperature is cold


Ambient air temperature is cold

Conditions (all active):


Ambient air temperature < -20 °C
Ambient air temperature status is Valid.

Cummins Inc. Revision Date: March 30, 2017 821


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

667. RefCondRefCond413.3: The DEF recirculation is active due to hot


shutdown.
The DEF recirculation is active due to hot shutdown.

Conditions (all active):


DEF Dosing State is in Off state
Pump state is in Preparing state
SCR inlet/midbed temperature ≥ 450°C AND SCR inlet/midbed temperature status is Valid when DEF
Dosing State enters Off state
(Ambient air temperature ≥ 30°C when DEF Dosing State enters Off state) OR (Ambient air
temperature status is Invalid)
Engine is in Engine Stopped state
Previous DEF Dosing State was Preparing or Dosing when DEF Dosing State moved to Off state.

Cummins Inc. Revision Date: March 30, 2017 822


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

668. RefCondRefCond414.1: Flag indicating that Engine is in Derate and


Urea Doser Functional Response Monitor fault is active.
Flag indicating that Engine is in Derate and Urea Doser Functional Response Monitor fault is active.

Conditions (all active):


5394.7-SE7927
Engine is in Derate

Cummins Inc. Revision Date: March 30, 2017 823


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

669. RefCondRefCond418.2: SCR Outlet temperature sensor data is not


available and not yet confirmed as faulty.
SCR Outlet temperature sensor data is not available and not yet confirmed as faulty.

Conditions (all active):


4363.3-SE6762, 4363.4-SE6763, 5743.12-SE6765
SCR Outlet Temperature sensor data is not available.

Cummins Inc. Revision Date: March 30, 2017 824


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

670. RefCondRefCond420.1: SCR Out temperature sensor reading no


value and not yet confirmed as faulty.
SCR Out temperature sensor reading no value and not yet confirmed as faulty.

Conditions (all active):


SCR Out temperature sensor reporting no value.

Cummins Inc. Revision Date: March 30, 2017 825


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

671. RefCondRefCond421.1: Block heater is detected


Block heater is detected

Conditions (all active):


The temperature drop detected on Coolant Temperature > 1.2 °C within a time period of 30 seconds
after the engine is started up.

Cummins Inc. Revision Date: March 30, 2017 826


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

672. RefCondRefCond426.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.) is true

Cummins Inc. Revision Date: March 30, 2017 827


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

673. RefCondRefCond427.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


NOT [The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)]

Cummins Inc. Revision Date: March 30, 2017 828


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

674. RefCondRefCond428.2: the enable conditions for the diagnostic


are specified as follows
the enable conditions for the diagnostic are specified as follows

Conditions (all active):


The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)

Cummins Inc. Revision Date: March 30, 2017 829


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

675. RefCondRefCond429.2: the disable conditions for the diagnostic


are specified as follows
the disable conditions for the diagnostic are specified as follows

Conditions (all active):


NOT [The in-tank mounted Urea Quality Sensor (UQS) detected as active. (See RefCond31.2.)]

Cummins Inc. Revision Date: March 30, 2017 830


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

676. RefCondRefCond430.3: The in-tank mounted measurement of DEF


tank level is valid without considering cold ambient conditions
The in-tank mounted measurement of DEF tank level is valid without considering cold ambient
conditions

Conditions (all active):


1761.11-SE8293, 1761.3-SE2896, 1761.4-SE2897
Keyswitch is ON
When the OEM has installed the J1939 interface SSI DEF level sensor, then: DEF level detection
element voltage shorted out of range high. (See RefCond259.2.) has not occurred during the previous
5 seconds.
When the OEM has installed the J1939 interface SSI DEF level sensor, then: Unknown failure of the
DEF level detection element, or DEF level detection element shorted out of range low. (See
RefCond260.1.) has not occurred during the previous5 seconds.
When the OEM has installed the J1939 interface WEMA DEF level sensor, then: DEF level detection
element voltage shorted to a high source or open circuit. (See RefCond253.2.) has not occurred
during the previous 5 seconds.
When the OEM has installed the J1939 interface WEMA DEF level sensor, then: DEF level detection
element voltage shorted to a low source. (See RefCond252.2.) has not occurred during the previous5
seconds.

Cummins Inc. Revision Date: March 30, 2017 831


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

677. RefCondRefCond454.1: Average SCR out temperature buffer is not


full
Average SCR out temperature buffer is not full

Conditions (all active):


4363.2-SE3785, 4363.3-SE6762, 4363.4-SE6763, 5742.9-SE12509, 5743.12-SE6765, 5862.2-SE2895
OR
30 sec have not elapsed since SCR Out average temperature calculation has started.

Cummins Inc. Revision Date: March 30, 2017 832


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

678. RefCondRefCond455.2: Fuel system failure is not present


Fuel system failure is not present

Conditions (all active):


5571.0-SE914
157.18-SE523
157.3-SE525, 157.4-SE526
157.7-SE7209, 157.7-SE7211
190.2-SE417, 190.2-SE54
3597.12-SE421
1349.3-SE6690, 1349.4-SE6691
651.7-SE3104, 652.7-SE3105, 653.7-SE3102, 654.7-SE3106, 655.7-SE3107, 656.7-SE3108

Cummins Inc. Revision Date: March 30, 2017 833


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

679. RefCondRefCond456.2: The inverted disable conditions for the


diagnostic are specified as follows
The inverted disable conditions for the diagnostic are specified as follows

Conditions (all active):


4334.3-SE5579
4334.4-SE5580
4334.16-SE7004
4334.18-SE7005
4334.15-SE12047
4334.7-SE12048
3362.31-SE6980
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
DEF Supply Module is in Dosing state.
Neither 4331.16-SE12528 nor 4331.18-SE12527 is updated in the current operation cycle.
Intrusive test timer is not completed.

Cummins Inc. Revision Date: March 30, 2017 834


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

680. RefCondRefCond457.1: UQS sensor internal temperature is above


the maximum operating range
UQS sensor internal temperature is above the maximum operating range

Conditions (all active):


(The internal temperature of the UQS > 125 °C) for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 835


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

681. RefCondRefCond458.1: Unknown failure of the UQS concentration


detection element, or UQS Concentration detection element
voltage shorted out of range low.
Unknown failure of the UQS concentration detection element, or UQS Concentration detection element
voltage shorted out of range low.

Conditions (all active):


The voltage measured across the concentration detection element charge pump < 0 volts for > 20
seconds.

Cummins Inc. Revision Date: March 30, 2017 836


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

682. RefCondRefCond459.1: DEF tank temperature sensor element


shorted to a high source or open circuit.
DEF tank temperature sensor element shorted to a high source or open circuit.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element > 4.87 volts OR the measured
DEF tank temperature < -40 °C) for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 837


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

683. RefCondRefCond460.1: DEF tank temperature sensor element


shorted to a low source.
DEF tank temperature sensor element shorted to a low source.

Conditions (all active):


(The voltage measured at the DEF tank temperature sensing element < 0.49 volts OR the measured
DEF tank temperature > 115 °C) > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 838


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

684. RefCondRefCond461.2: Conditions to enable the Key-Off Pressure


Decay diagnostics
Conditions to enable the Key-Off Pressure Decay diagnostics

Conditions (all active):


4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.7-SE7927
3362.31-SE6980
Key switch is OFF
DEF dosing module state is Off
DEF dosing module previous state is in Dosing
NOT[Engine running condition (See RefCond368.1.)]
Not [The DEF recirculation is active due to hot shutdown. (See RefCond413.3.)]

Cummins Inc. Revision Date: March 30, 2017 839


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

685. RefCondRefCond462.2: Condition to check the DEF pressure value


at the rising event when KeyOff pressure decay diagnostics is
enabled
Condition to check the DEF pressure value at the rising event when KeyOff pressure decay diagnostics is
enabled

Conditions (all active):


Supply module DEF pressure ≥700kPa(absolute) on rising event of Conditions to enable the Key-Off
Pressure Decay diagnostics (See RefCond461.2.)

Cummins Inc. Revision Date: March 30, 2017 840


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

686. RefCondRefCond463.2: The returnline blockage diagnostics is


complete when the diagnostics has been enabled for a calibrated
period of time
The returnline blockage diagnostics is complete when the diagnostics has been enabled for a calibrated
period of time

Conditions (all active):


Condition to check the DEF pressure value at the rising event when KeyOff pressure decay diagnostics
is enabled (See RefCond462.2.) is TRUE for ≥ 20sec

Cummins Inc. Revision Date: March 30, 2017 841


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

687. RefCondRefCond464.2: Conditions to check if the returnline


blockage diagnostic error flag has been set.
Conditions to check if the returnline blockage diagnostic error flag has been set.

Conditions (all active):


DEF Doser Module pressure captured at (Condition to check the DEF pressure value at the rising event
when KeyOff pressure decay diagnostics is enabled (See RefCond462.2.)) - DEF Doser Module
pressure sample captured after 20sec, in which the DEF pressure has decayed naturally, ≤
400kPa(absolute)

Cummins Inc. Revision Date: March 30, 2017 842


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

688. RefCondRefCond465.2: Conditions to check if the Sensor Stuck


diagnostics is complete
Conditions to check if the Sensor Stuck diagnostics is complete

Conditions (all active):


Condition to check the DEF pressure value at the rising event when KeyOff pressure decay diagnostics
is enabled (See RefCond462.2.) is TRUE for ≥ 15 sec
The returnline blockage diagnostics is complete when the diagnostics has been enabled for a
calibrated period of time (See RefCond463.2.) is TRUE for ≥ 15 sec
Conditions to check if the returnline blockage diagnostic error flag has been set. (See RefCond464.2.)
is TRUE for ≥ 15 sec

Cummins Inc. Revision Date: March 30, 2017 843


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

689. RefCondRefCond466.1: DPF delta pressure sensor error is


detected.
DPF delta pressure sensor error is detected.

Conditions (all active):


3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857
OR
3610.10-SE2983 is active.

Cummins Inc. Revision Date: March 30, 2017 844


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

690. RefCondRefCond467.1: Active faults with DPF delta pressure


sensor defaulted.
Active faults with DPF delta pressure sensor defaulted.

Conditions (all active):


102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365,
1176.4-SE8366, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493, 1209.4-SE494, 411.2-
SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877, 412.2-SE3878
DPF delta pressure sensor error is detected. (See RefCond466.1.)

Cummins Inc. Revision Date: March 30, 2017 845


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

691. RefCondRefCond468.1: Dosing check conditions for Non-Regen


severe temperature faults.
Dosing check conditions for Non-Regen severe temperature faults.

Conditions (all active):


H2O thermal request is true OR total hydrocarbon feedback ≥ 0.05 g/sec

Cummins Inc. Revision Date: March 30, 2017 846


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

692. RefCondRefCond469.2: Enable Conditions for DEF dosing


command adjustment.
Enable Conditions for DEF dosing command adjustment.

Conditions (all active):


3521.16-SE13409, 3521.18-SE13411
{
OR
Level independent urea high concentration diagnostic is in progress OR Improper reductant
diagnostic is in progress
}
Sampled urea concentration ≥ 36 Percent OR (Sampled urea concentration ≤ 26 Percent AND Sampled
urea concentration ≥ 22.5 percent)

Cummins Inc. Revision Date: March 30, 2017 847


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

693. RefCondRefCond475.2: Reactive regen trigger is active.


Reactive regen trigger is active.

Conditions (all active):


Reactive regen trigger enabling conditions are active. (See RefCond473.2.)
NOT[Decomposition Reactor Pipe (DRP) regeneration is completed (See RefCond474.2.)]

Cummins Inc. Revision Date: March 30, 2017 848


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

694. RefCondRefCond476.2: Decomposition Reactor Pipe (DRP)


regeneration request is not active
Decomposition Reactor Pipe (DRP) regeneration request is not active

Conditions (all active):


NOT[Reactive regen trigger is active. (See RefCond475.2.)] .

Cummins Inc. Revision Date: March 30, 2017 849


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

695. RefCondRefCond477.38: The enable conditions for the diagnostic


are specified as follows
The enable conditions for the diagnostic are specified as follows

Conditions (all active):


4334.3-SE5579
4334.4-SE5580
4334.16-SE7004
4334.18-SE7005
4334.15-SE12047
4334.7-SE12048
3362.31-SE6980
3242.2-SE13174, 3242.2-SE13177, 3242.2-SE2844, 3246.2-SE13175, 3246.2-SE2852, 3246.21-
SE13178, 3246.3-SE6733, 3246.3-SE6737, 3246.4-SE6734, 5742.11-SE7168, 5742.12-SE6721, 5742.12-
SE6722, 5742.12-SE6724, 5742.12-SE6725, 5742.12-SE6726, 5742.3-SE6727, 5742.4-SE6728, 5742.9-
SE12508
102.2-SE4439, 102.20-SE3651, 102.21-SE3652, 102.3-SE489, 102.4-SE490, 105.2-SE3793, 105.2-
SE4070, 105.3-SE487, 105.4-SE488, 1209.2-SE3922, 1209.2-SE3924, 1209.2-SE4442, 1209.3-SE493,
1209.4-SE494, 411.2-SE1911, 411.3-SE485, 411.4-SE483, 412.2-SE3872, 412.2-SE3876, 412.2-SE3877,
412.2-SE3878
171.2-SE3799, 171.2-SE3871, 171.3-SE3802, 171.4-SE3803
1176.2-SE8698, 1176.2-SE8699, 1176.2-SE8802, 1176.3-SE8365, 1176.4-SE8366
DEF Supply Module is in Dosing state.
(
Urea Doser Functional Response Monitor is ready to update the fault. (See RefCond127.12.) AND
(5394.7-SE7927 is NOT active).
OR
DEF injection rate > 0.02 ml/sec for 10 seconds.
)
10 seconds has elapsed after the OBD arbitrator completes the Urea Doser Functional Monitor run.
SCR Inlet Mass flow rate ≥ 100 g/s.
230 DegC ≤ SCR Inlet/Midbed Temperature ≤ 420 DegC.
75 kPa(absolute) ≤ Ambient air pressure
Ambient air temperature > -6.7 °C
Neither 4331.16-SE12528 Nor 4331.18-SE12527 is updated in the current operation cycle.
The OBD arbitrator allows the 4331.16-SE12528 AND 4331.18-SE12527 to run.
Reductant delivery monitor frequency check is satisfied (See RefCond500.2.)

Cummins Inc. Revision Date: March 30, 2017 850


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

696. RefCondRefCond478.38: DEF intrusive dosing window is active


DEF intrusive dosing window is active

Conditions (all active):


The enable conditions for the diagnostic are specified as follows (See RefCond477.38.)
DEF intrusive dosing time < 30 seconds

Cummins Inc. Revision Date: March 30, 2017 851


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

697. RefCondRefCond480.1: The enable conditions for the DEF Tank


Temperature Internal error diagnostic are specified as follows
The enable conditions for the DEF Tank Temperature Internal error diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)

Cummins Inc. Revision Date: March 30, 2017 852


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

698. RefCondRefCond481.1: The disable conditions for the DEF Tank


Temperature Internal error diagnostic are specified as follows
The disable conditions for the DEF Tank Temperature Internal error diagnostic are specified as follows

Conditions (all active):


3031.13-SE8567, 3031.9-SE7666
OR
NOT [the in-tank mounted DEF tank temperature sensor detected as active (See RefCond228.2.)]

Cummins Inc. Revision Date: March 30, 2017 853


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

699. RefCondRefCond485.1: DPF delta pressure sensor error is not


detected.
DPF delta pressure sensor error is not detected.

Conditions (all active):


3251.10-SE2851, 3251.3-SE2849, 3251.4-SE2857
3610.10-SE2983 is not active.

Cummins Inc. Revision Date: March 30, 2017 854


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

700. RefCondRefCond486.1: Enable Solid Lamp based on regeneration


of DPF trigger states.
Enable Solid Lamp based on regeneration of DPF trigger states.

Conditions (all active):


Soot based regeneration of DPF is active.
OR
Delta Pressure based regeneration of DPF is active.
OR
Override based regeneration of DPF is active.
OR
Timer based regeneration of DPF is active.
OR
Timed based Non Mission regeneration of DPF is active.
OR
Forced Service based regeneration of DPF is active.
OR
Deep Clean based regeneration of DPF is active.
OR
Reactive based regeneration of DPF is active.

Cummins Inc. Revision Date: March 30, 2017 855


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

701. RefCondRefCond489.1: The sensor has completed the DEF type


detection process, and has determined that the fluid in the DEF
tank is not DEF.
The sensor has completed the DEF type detection process, and has determined that the fluid in the DEF
tank is not DEF.

Conditions (all active):


On completion of DEF type detection process, sensor has determined that the fluid in the DEF tank is
other than DEF.

Cummins Inc. Revision Date: March 30, 2017 856


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

702. RefCondRefCond490.2: Conditions to abort the Key-Off Pressure


Decay diagnostics
Conditions to abort the Key-Off Pressure Decay diagnostics

Conditions (all active):


3362.31-SE6980, 4334.3-SE5579, 4334.4-SE5580, 4375.3-SE6095, 4375.4-SE6094, 5394.7-SE7927
OR
Key switch is ON
OR
DEF dosing module state is not Off
OR
DEF dosing module previous state is not Dosing
OR
Supply module DEF pressure < 700 kPa(absolute)
OR
NOT[Engine running condition (See RefCond368.1.)]
OR
The DEF recirculation is active due to hot shutdown. (See RefCond413.3.)

Cummins Inc. Revision Date: March 30, 2017 857


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

703. RefCondRefCond491.1: DEF level detection element voltage


shorted to a high source or open circuit.
DEF level detection element voltage shorted to a high source or open circuit.

Conditions (all active):


The voltage measured at the DEF tank level sensing element > 4.69 volts for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 858


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

704. RefCondRefCond492.1: DEF level detection element voltage


shorted to a low source.
DEF level detection element voltage shorted to a low source.

Conditions (all active):


The voltage measured at the DEF tank level sensing element < 0.3 volts for > 20 seconds.

Cummins Inc. Revision Date: March 30, 2017 859


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

705. RefCondRefCond500.2: Reductant delivery monitor frequency


check is satisfied
Reductant delivery monitor frequency check is satisfied

Conditions (all active):


4331.16-SE12528 is active.
OR
4331.18-SE12527 is active.
OR
4375.2-SE12526 is active.
OR
Reductant delivery monitor intrusive diagnostics has not completed its first run since the calibration
download.
OR
(
1,200 seconds has elapsed since the previous reductant delivery monitor intrusive diagnostic run is
completed OR ((SCR inlet/Midbed temperature ≥ 280°C AND SCR inlet/Midbed temperature status is
Valid) For 5 seconds since previous reductant delivery monitor intrusive diagnostic run is completed).
Engine running condition (See RefCond368.1.)
)

Cummins Inc. Revision Date: March 30, 2017 860


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

706. RefCondRefCond507.1: Any of the DEF Doser related errors are


active.
Any of the DEF Doser related errors are active.

Conditions (all active):


OR
NOT[None of the Urea Supply Module related errors are active (See RefCond506.1.)]

Cummins Inc. Revision Date: March 30, 2017 861


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

707. RefCondRefCond508.1: Any of the DEF Doser related errors are


active.
Any of the DEF Doser related errors are active.

Conditions (all active):


Any of the DEF Doser related errors are active. (See RefCond507.1.)

Cummins Inc. Revision Date: March 30, 2017 862


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

708. RefCondRefCond509.2: Aftertreatment Inlet NOx sensor reading is


not valid.
Aftertreatment Inlet NOx sensor reading is not valid.

Conditions (all active):


3216.4-SE5153, 3216.9-SE2487, 3218.2-SE5152, 3222.5-SE5151
OR Exhaust gas temperature is below a threshold or above a threshold for insufficient time
representing that dew point is not reached. (See RefCond9.6.)
OR Exhaust gas temperature is above a threshold representing the point at which there is no longer a
concern of condensation on the NOx sensor element. (See RefCond7.6.) for less than 100 seconds
OR NOx sensor reading is not valid due to internal control loops within the sensor being unstable..
(See RefCond8.5.)
OR Aftertreatment inlet NOx sensor has not reached its internal working temperature of 800 °C.
OR Aftertreatment Inlet NOx sensor supply voltage > 16.5 V or Aftertreatment Inlet NOx sensor
supply voltage < 10.8 V

Cummins Inc. Revision Date: March 30, 2017 863


OBD Operation for B6.7 CM2350 B121B – Engine Model Year 2017

709. RefCondRefCond668.1: Engine control module off time is greater


thean a calibrated threshold.
Engine control module off time is greater thean a calibrated threshold.

Conditions (all active):


Engine control Module Off Time > 864,000 sec

Cummins Inc. Revision Date: March 30, 2017 864

Вам также может понравиться