1.5
1
Receiver noise
0.5
0
1 10 100
DEPTH [m]
Execute the following clause 3 when one of levels is lower than other channels.
2/4
3. Replace the line of transducer for the confirmation, and confirm the receiver output.
TB2 TB2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Replace
Return it when
1 2 3 1 2 3
the confirmation ends.
Fore thermistor After Fore After
thermistor
Fig.5 normal connection Fig.6 confirmation connection
When the channel (TP452 or TP454) with low level moves, it is a breakdown of transducer:CFT-22B.
When the channel (TP452 or TP454) with low level is not change, it is a break in the circuit:CMN-686.
After (damage)
after replace the line
Fore
(normal)
TP452 = 1.5V
TP454 = 2.1V Fig.7 Image of transducer damage
5. When not becoming normal even if the check and the repair
Describe the result of the check and the repair to the check sheet(last page).
And contact the Marine Service Department of JRC.
3/4
CDC-1228 CMN-686
TP7 TP6
GND TXG
TP404
TP450
GND
GND
F400
2A
Transformer
Transducer
cable
4/4
Company:
Measurer:
JLN-205 Doppler Log
Measurement Date:
Name of Vessel:
Measurement Place:
Situation of
A
abnormal
TP454 V V V V
Voltage [V] Range [ms]
2. TP452 V ms
Bottom Echo
TP454 V ms
TP452 V
Noise voltage
TP454 V
normal reverse
TP452 V V
3. Transducer line replace
TP454 V V
*:Please send this sheet to the Marine Service dept. after completing the confirmation.