Вы находитесь на странице: 1из 4

Version Category

19031270 EN 81-1 First Release

19031866 Bug Fix

19040269 Improvement
Bug Fix

19053057 Improvement
Improvement
Improvement
Improvement
Improvement
Improvement
Improvement
Bug Fix
Bug Fix
Bug Fix

19071261 EN 81-20 First Release

19073067 Improvement
Improvement
Improvement

19082850 Bug Fix

Improvement

Improvement

Improvement

Improvement

Improvement
Improvement
Improvement

Improvement

19101046 Improvement
Improvement
Improvement
Improvement

19111447 Improvement

Improvement

Improvement

Improvement
Improvement

19121163 Improvement
Improvement
Improvement
Improvement
Improvement
Improvement
Description

Car Light Relay is not functional on FX_CUBE board. It's fixed.

Mono phase reduced speed mode is added.


Manual door operation is fixed. "Please close the door" announcement is added.

Synchronous motor feature is added.


(SEV) Manuel evacuation switch input function is added.
(BRC) Mechanical brake checkback input function is added.
(BRC2) Mekanik brake-2 checkback input function is added.
(CCC) Cancel car commands input function is added.
2.38:Car fan control parameter is added.
5.25:Rotor slip compensation gain parameter is added.
Door open indication 'L' and 'C' for manual doors is fixed.
Timing of please close the door announcement for manual doors is fixed.
Fire evacuation and Fireman mode operations are fixed.

Limit switch and buffer tests are added.


"2.39:Maintenance time control" and "2.40:Maintenance time" parameters are added.
"5.26:Safety gear unjamming" function is added.

Rescue operation in open loop does not work well after 19071261 version. It is fixed.
12:FX-CUBE voice settings parameter is added.
12.1:Voice language (English / Turkish)
12.2:Number of floors below ground (0 / 1 / 2 / 3)
12.3:Type of floors below ground (Minus / Basement / Autopark)
12.4:Order of ground floor and above (1,2,3 / Entrance,1,2,3 / Ground floor,1,2,3 / Lobby,1,2,3)

NOTE: For the correct operation of these parameters, the latest ARCUBE folder content from the website must be copied

FX-CUBE-S and CPC boards are added to the system for serial COP support.
2.6B:COP wiring system parameter is added. If the FX-CUBE board is used in the system, this parameter must be selecte
CUBE-S board is used, it is selected as "Serial".

10.4:FX-CUBE-S PI programmable inputs are added.


10.5:CPC PI programmable inputs are added.
11.3:FX-CUBE-S PR programmable outputs are added.
11.5:FX-CUBE-S PT programmable outputs are added.
11.6:CPC PO1 programmable output is added.
11.7:CPC PT1 programmable output is added.

NOTE: These parameters are active when parameter 2.6B is selected as "Serial".

9.5A:Floor text settings parameter is added.


7.12:LIR delay parameter is added.
Statistics screen is added.
1:Direction change count
2:Stop-go counter
3:Travel distance(meter)
4:Travel time(minute)
5:Runtime(minute)
6:Door opening count

The screen shows the following values about the selected statistics:
-Since factory release
-Since last reset
-Resetting count

2.41:Direction change count limit parameter is added. If the value is set to "0", the direction change control is disabled.

6.10:Pre-torque with analog load cell parameter is added.


Pre-torque(PT) info screen is added.
To enter the rescue in mono phase reduced speed mode, (FRM) Force to rescue mode programmable input function is ad
(AFLT) Filter unnecessary alarms programmable output function is added.

"Smart torque estimation" is added to Pre-Torque options. This option can only be used in synchronous motors.
Options of 6.10 Pre-Torque function parameter is changed:
- Disabled
- With analog load cell
- Smart torque estimation

2 stop support is added to shaft position system with encoder.


Manual movement option with screen buttons is added. Releveling test can be done with this option. To do this, enter the m
and select "Releveling" as speed, then press Up or Down button to move the car. After the car moves 3-4 cm, exit the man
start releveling.

9.32:PI inputs on LOP boards parameter is added.


9.33:Floor chime type parameter is added.

Auto-tune without ropes (Rotating) option is added for synchronous motors..


Evacuation on recall mode feature is added.
"2.16C:Fire signal state" parameter is added. (Not permanent / Permanent)
"2.42:When safety chain (120) is OFF" parameter is added. (Resume operation when 120 is back ON / Block elevator)
"8.7:Door state after rescue" parameter is added. (Waits with door closed / Waits with door open)
Russian and Polish languages are added.