Вы находитесь на странице: 1из 6

Document number: 252052042A

Technical Note Mini-M - 306X.

Description: Some AUX phone’s will not ring on a incoming call. And some fax’s will not “go
off hook” / answer a incoming call.

Background: Due to a change in the SLIC circuit , ( SLIC IC L3000N is discontinued )


the ringing voltage is reduced.
The change is made from PL 60-106993-AF and PL 60-110497-J.

Action: In order to increase the ringing voltage the transistor Q 1909 has to be removed and a link
between the -44 VDC and the -24 VDC has to be made. Fig. 4. ( Q1909 ).
This will cause the voltage to increase to -44 VDC.
In order for the SLIC circuit to handle the increase in voltage, the transistors has to be replaced.
Fig. 3. ( Q1901, Q1902, Q1903, Q1905, Q1906, Q1907 ).

The transistors will be available on http://www.tt.dk/extra/spareparts_minimport.asp


S-67-120-955. Kit SLIC up-date / MM.

All new terminals, ( Y/W 2004 / 24 ) will be updated from factory.


All terminals returned from repair at T&T will be updated.
All terminals, if under warranty, will be updated free of charge, if shipped to a CSC or T&T.

Old SLIC circuit New SLIC circuit

Q1909

Thrane & Thrane A/S www.tt.dk


Lundtoftegaardsvej 93D support@tt.dk
DK-2800 Lyngby
Denmark
Document number: 252052042A

In order to increase the ringing voltage remove Q1909, and make a link between
the -44 VDC and the -24 VDC.

fig. 1

Remove Q1909 and make a link


between -44 VDC and -24 VDC

In order for the SLIC circuit to handle the increased voltage, replace the transistors,
according to the below diagram.

fig. 2.

Replace BC846B with


FMMT493 (Q1901)

Replace BSR16 with


FMMT593 (Q1903)
Replace BC846B with
FMMT493 (Q1902)

Replace BC846B with


FMMT493 (Q1905)

Replace BSR16 with


Replace BC846B with
FMMT593 (Q1907)
FMMT493 (Q1906)

Thrane & Thrane A/S www.tt.dk


Lundtoftegaardsvej 93D support@tt.dk
DK-2800 Lyngby
Denmark
Document number: 252052042A

PCB layout.
Fig. 3.

Q1901

Q1906 Q1905

Q1902
Q1905

Q1907

Thrane & Thrane A/S www.tt.dk


Lundtoftegaardsvej 93D support@tt.dk
DK-2800 Lyngby
Denmark
Document number: 252052042A

PCB layout.

Fig. 4.

J5 - AUX

Remove Q1909 and make a link between C-E

U518

U512

Thrane & Thrane A/S www.tt.dk


Lundtoftegaardsvej 93D support@tt.dk
DK-2800 Lyngby
Denmark
Document number: 252052042A

How to check if the main board needs update.

Is the PL code within the range witch needs update ?.


From PL 60-106993-AF to PL-60-106369-AJ.03
and from PL 60-110497-J. to 60-110497-AJ.03
To check PL rev se below fig. 5..

fig. 5.

Thrane & Thrane A/S www.tt.dk


Lundtoftegaardsvej 93D support@tt.dk
DK-2800 Lyngby
Denmark
Document number: 252052042A

To check if the main board is updated.

Check if Q1909 has been removed and link has been made.