Вы находитесь на странице: 1из 2

MANGLA HOISTS PVT LTD

3C/2,ECOTECH II,UDYOG VIHAR,GREATER NOIDA - 201306


Internal/Final Inspection Report for DG/SG EOT Crane
IR No:
Date:
Cont.No. Eqpt No. Drg No.
Hoist /Crane Capacity (T) Lift (Mtr) No. of Falls Wire rope Drum Dia No. Of Beam Path Nature of Beam Size
Details Dia Turns Path
Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs.
EOT Hoist
EOT Crane
Gear Box Sound NO LOAD: ON LOAD : Balancing of hoist : OIL LEAKEGES:
Hoist /Crane Details
Motor Details Sr. No Make Pole KW Amp Insulation Class
Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs.
Hoisting Motor
Auxiliary Motor
C.T Motor-I
CT Motor-II
L.T Motor-I
L.T Motor-II

Rated Load Test (With out VFD)


Movement Specified Speed Observed Speed Distance(mm) Time(Sec) Current Amp
Phase I Phase II Phase III
UP
DOWN
LEFT
RIGHT
Rated Load Test (With VFD)
Movement Specified Speed Observed Speed Distance(mm) Time(Sec) Current in Amp(as per drive)
UP
SLOW
DOWN
UP
FAST
DOWN
LEFT
SLOW
RIGHT
LEFT
FAST
RIGHT
Dimension
A B C D E
Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs. Spec Obs.

Item Make Rating/Identity Function Remark


Hook T S.No. Painting
Wire rope Visual
Brake (Sr.no / Model no.) Balancing
Pendent Ways UP/DOWN/CT (L & R)
Over Load Test Remarks
Remarks
At 125% of Safe Working Load (c) Brake Function (Hoisting)
(a) UP & DOWN Movement (d) Limit Switch Function (Hoist)
(b) Lifting from mid Air

Panels Remarks Panels


Remarks
Power-H.V. Test Power 2.5 KV for 1 Min Power-I.R Test Power 1000 V DC for 1 Min
Control -H.V Test Power 1.5 KV for 1 Min Control -I.R Test Power 1000V DC for 1 Min
DOP -By Paper Insertion Method, Paper should not Slide
For SG/DG Cranes SWL Span Deflection Wheel Base
Specified Observed Specified Observed Specified Observed Specified Observed

For MANGLA HOIST PVT LTD


ORGINAL Witness by (Quality Department)
MHPL/INSP/09,Rev-00, Dtd: 01.09.16