Вы находитесь на странице: 1из 12

(SEBP4980 - ) - Service Information System Page 1 of 12

Shutdown SIS

Previous Screen

Product:  MOTOR GRADER 
Model:  120M MOTOR GRADER B9C01204 
Configuration: 120M Motor Grader B9C00001-UP (MACHINE) POWERED BY C6.6 Engine 

Troubleshooting
®
Cat Grade Control Cross Slope System for Motor Graders
Media Number -M0068530-01 Publication Date -01/04/2018 Date Updated -12/04/2018

i07358242

Diagnostic Trouble Codes


SMCS - 1900; 7006; 7490; 7569; 7610

The following is a list of Diagnostic Trouble Codes (DTCs). When a diagnostic code becomes active,
refer to the Troubleshooting section of this manual for a specific troubleshooting procedure.

Troubleshooting the Cat® Grade Control System (Cross Slope)


Note: Before performing maintenance, ensure the following:

• The blade is fully rested on the ground

• The parking break is engaged

• The key switch on the OFF position and the master disconnect switch is disconnected

• Machine is in a safe condition and away from any working personal

• All the safety steps to perform the maintenance procedure on the machine has been
implemented.

Troubleshooting the Cat Grade Control System Sensors

The following is the list of codes that are associated to the Cat® Grade Control Sensors Data link and
calibrations.

Table 1
Implement ECM 1 (MID 82)
DTC Failure Mode (FMI) Description
871 09 Inclination Sensor / Abnormal Update
908 09 Blade Rotation Position Sensor / Abnormal Update
3694 09 Blade Slope Sensor / Abnormal Update

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 2 of 12

Code 871 is related to the Inclination (Main-Fall) Sensor.

Code 908 is related to the Blade Rotation Sensor.

Code 3694 is related to the Blade Slope Sensor.

Probable Causes

• Intermittent wires connection with CAN data link.

• CAN Data link wires shorted to the machine ground, machine power circuit or both CAN wires
are shorted together.

Note: When CAN Wires Shorted to the machine ground or to each other, the entire CAN Data Link
Bus and every component connected to it will be impacted and there will be more codes and failure
modes related to each of this component.

• Sensor has no power supply.

• Defective sensor

• Defective Implement ECM

Note: Machine ECM failure is unlikely.

Steps to Isolate the Problem and Solution

Perform the below steps to troubleshoot the sensors:

Note: After completing the troubleshooting step, ensure that the step is checked correctly and then
move to the next troubleshooting step. If any of the steps is incorrectly checked, stop and investigate
it, then correct it.

1. Measure the power supply to the sensor, ensure that there is a 24 volts between Pin A+ and Pin
B ground, Refer to the Table 2 below or the machine schematic for more information.

2. Visually check the harness wires and the connectors from the sensors to the implement ECM,
ensure that there is no damages or broken wires.

3. Perform resistance (Ohm) check between the CAN high and CAN low wires. Ensure that there
is a 60 Ω (Ohms) between them.

4. Perform resistance (Ohm) check between the CAN wires from the sensor connector and the
machine ground. Ensure that there is no conductivity between them.

5. Perform a resistance (Ohm) check between the CAN wires from the sensor connector and the
machine power supply circuit. Ensure that there is no conductivity between them.

6. Perform a resistance (Ohm) check between the CAN wires from the sensor connector to the
machine Implement ECM Connector. Ensure that there is a conductivity between the sensor
connector pins and the ECM connector pin. Refer to the Table 2 or the machine schematic for
more information.

7. Replace the sensor that is related to the diagnostic code.

8. Replace the Machine Implement ECM.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 3 of 12

Note: Failure of machine ECM is highly unlikely.

Note: Refer to the Table 2 and the machine schematic or the connector contact descriptions
section of this manual.

Cross Slope System Sensor Connectors

Illustration 1 g06071963
Connector contact

Table 2
Implement 1 ECM Power Module PM400
Pin Contact Description
Connector/Pin Connector/Pin
A switch power - GR-C2-A or RV-C11-A
B switch power return - GR-C2-B or RV-C11-B
C J1939 CAN A data link high J2-67 -
D J1939 CAN A data link low J2-68 -
switched power return
E - GR-C2-F or RV-C11-F
(AWAKE RTN)
switched power return
F - GR-C2-F or RV-C11-F
(AWAKE RTN)

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 4 of 12

Illustration 2 g06089533
CAN Data Link

Table 3
Implement ECM 1 (MID 82)
DTC Failure Mode (FMI) Description
871 13 Inclination Sensor / Out of Calibration
908 13 Blade Rotation Position Sensor / Out of Calibration
3694 13 Blade Slope Sensor / Out of Calibration

Code 871 is related to the Inclination (Main-fall) Sensor.

Code 908 is related to the Blade Rotation Sensor.

Code 3694 is related to the Blade Slope Sensor.

When any of the Sensors become loose from the mounting bracket, reinstalled or replaced the Cat
Grade control System requires that sensor to be realigned and recalibrated in order for the system to
be accurate. Refer to Testing and Adjusting Manual for instructions on aligning and calibrating the
Cat Grade Control Sensors.

• The sensor is not secured to the bracket

• The sensor has been removed, reinstalled, or replaced

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 5 of 12

• Sensors that related to the diagnostic code requires calibration

• Sensor failure

1. Ensure that the sensor related to the diagnostic code is secured to the mounting bracket.

2. Measure the power supply to the sensor connector between Pin A Positive and Pin B RTN
GND, ensure that there is close to 24 volt present. Correct any problem.

3. Ensure that the sensor is aligned properly and recalibrate it. Refer to the realigning and
calibration section on this manual.

4. Replace the sensor that related to the diagnostic code, align it and then calibrate it.

Table 4
Implement ECM 1 (MID 82)
Failure Mode
DTC Description
(FMI)
03 Blade Slope Sensor Power Supply / voltage above normal
3695
04 Blade Slope Sensor Power Supply / voltage below normal
Blade Rotation Angle Sensor Power Supply / voltage above
03
normal
3696
Blade Rotation Angle Sensor Power Supply / voltage below
04
normal
Inclination (Main fall) Sensor Power Supply / voltage above
03
normal
3699
Inclination (Main fall) Sensor Power Supply / voltage below
04
normal

Code 3695 with FMI 03 or 04 is related to the Blade Slope Sensor power supply circuit.

Code 3696 with FMI 03 or 04 is related to the Blade Rotation Sensor power supply circuit.

Code 3699 with FMI 03 or 04 is related to the Inclination (Main-fall) Sensor power supply circuit.

Note: The System will generate a Level 2 warning when any of the diagnostic codes in the above
table with FMI 03 and FMI 04 become active.

• Intermittent or damages to harness wires connection to the sensor from the Power Module
PM400.

• The out power supply from the power module PM400 to the sensor is missing.

• The power module PM400 input power supply is missing.

Note: When the power model power supply is missing, all the system sensors will generate the same
failure mode indicating that there is no power supply to them.

• An open circuit

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 6 of 12

• A component failure of the sensor or the power module PM400.

• Machine implement ECM failure.

Note: Failure of machine ECM is highly unlikely.

1. Visually check the wires and the connectors from the sensors to the implement ECM, ensure
that there is no damages or broken wires. Correct any problems.

2. Disconnect the sensor from the machine harness connector and while the machine key switch is
in the ON position measure the power supply between Pin A + and Pin B ground ensure that
there is a proper power supply (close to 24 volts) from the power model PM400. Correct any
problems.

Refer to the Table 5 and 6 or the machine schematic.

3. If there is a power supply present while the sensor is disconnected from the machine harness,
measure the power supply to the sensor while it is connected to machine by inserting needle
group described in service tool section from the back of the sensor connector to measure the
power supply between Pin A + and Pin B ground, ensure that there is sufficient power supply
present (close to 24 volts) from the power module PM400 and there is no disappearance or
significant drop of the voltage to ensure that there is no internal shortages inside the sensor
circuit. Replace the sensor if significant drops of the voltage happened while it is connected to
the machine harness.

4. If the power supply is missing to the sensor while the connector is disconnected, ensure that
there is a power supply present to the input and the output of the power module PM400 and
also the awake and awake RTN is present. Refer to the Table 5 and 6 or the machine schematic
for more information.

5. Replace the sensor or the power model PM400 if failure occurs.

6. Replace the Implement ECM.

Note: Failure of machine ECM is highly unlikely.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 7 of 12

Illustration 3 g06071963
Connector contact

Table 5
Pin Description
A + BATT 1
B GND
C + BATT 2
D GND
E -
F -
G + BATT 3
H GND

Illustration 4 g06071963
Connector contact

Table 6
Pin Description
A Switched power 1
B Switched power RTN 1
C Switch power 2
D Switched power RTN 2
E Awake

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 8 of 12

F Awake RTN
G Switched power 3
H Switched power RTN 3

Troubleshooting the Cat Grade Control System Operator Control


(Automatic/Manual) Switches

Table 7
Implement ECM 1 (MID 82)
Failure Mode
DTC Description
(FMI)
Left Blade Control Mode (Automatic/Manual) Switch / voltage
03
above normal
2258
Left Blade Control Mode (Automatic/Manual) Switch / voltage
04
below normal
Right Blade Control Mode (Automatic/Manual) Switch / voltage
03
above normal
2259
Right Blade Control Mode (Automatic/Manual) Switch / voltage
04
below normal

Code 2258 with FMI 03 and 04 is related to the Left Blade Control Mode (Automatic/Manuel)
Switches circuit.

Code 2259 with FMI 03 and 04 is related to the Right Blade Control Mode (Automatic/Manuel)
Switches circuit.

Note: The System will generate a Level 2 warning when any of the diagnostic codes in the above
table with FMI 03 and FMI 04 become active.

Probable Causes

• Intermittent or damages to the switch wiring circuit.

• A component has failed (Switch).

• A component has failed (Machine Implement ECM).

Note: Failure of the ECM is highly unlikely.

Steps to Isolate the Problem and Solution

1. Visually check the wires and the connectors from the switch connector to the implement ECM,
ensure that there is no damages or broken wires. Correct any problems.

2. Perform contact connections check using an Ohm meter to the switch pins while it is
disconnected from the machine harness and replace it, if it is not working properly. Refer to the
Table 9.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 9 of 12

3. Perform a resistance (Ohm) check of the circuit wires to the machine Implements ECM
Connector. Refer to the Table8 or the machine schematic for more information.

4. Replace the Implement ECM if all conditions and steps above are correct and functioning in a
proper way.

Note: Failure of machine Implement ECM is highly unlikely.

5. To troubleshoot the automatic/manual switches on the machine equipped with Advance


Joystick, refer to machine schematic.

Right and Left Blade Control Mode Switch (Auto/Man Switch)

Illustration 5 g06076493

Table 8
Wiring Table LH/ RH Switch ECM Input LH/ RH Switch Implement ECM
Pin Circuit Color Signal Input Signal

A N/C White J2/53 (N/C) J2/60 (N/C)


B N/O Brown J2/52 (N/O) J2/59 (N/O)
C Common Black J2/22 Digital Return J2/22 Digital Return (GND)

Ohm checking the RH/LH Side Blade Control Mode Switches (Auto/Man switches) using ohm
meter.

Disconnect the Auto/Man Switch from the machine harness and perform the following contact
connection check using the ohm meter

Table 9
RH/LH Auto/Manual Switch
Contact Connections Between When Switch Not Pressed When Switch Pressed
PIN B and PIN A Closed Circuit Opened Circuit
PIN B and PIN C Opened Circuit Closed Circuit
PIN A and PIN B Opened Circuit Opened Circuit

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 10 of 12

Table 10
Implement ECM 1 (MID 82)
Failure Mode
DTC Diagnostic Code Procedure
(FMI)
Left Desired Grade Offset (Increment/Decrement) Switch / voltage
03
above Normal
2261
Left Desired Grade Offset (Increment/Decrement) Switch / voltage
04
below Normal
Right Desired Grade Offset (Increment/Decrement) Switch / voltage
03
above Normal
2262
Right Desired Grade Offset (Increment/Decrement) Switch / voltage
04
below Normal

Code 2261 with FMI 03 or 04 is related to the Left Desired Grade Offset (Increment/decrement)
Switch power circuit.

Code 2262 with FMI 03 and 04 is related to the Right Desired Grade Offset (Increment/Decrement)
Switch power circuit.

Note: The System will generate a Level 2 warning when any of the diagnostic codes in the above
table with FMI 03 and FMI 04 become active.

• Intermittent or damages to the switch wiring circuit.

• A component has failed (Switch).

• A component has failed (Machine Implement ECM).

Note: Failure of ECM is highly unlikely.

1. Visually check the machine harness from the switch connector to the implement ECM
connector, ensure that there is no damages or broken wires. Correct any problem.

2. Perform contact connections check using an Ohm Meter to the switch pins while it is
disconnected from the machine harness and replace it, if it is not working properly. Refer to the
Table 13 or the machine schematic for more information.

3. Disconnect the sensor connector and the machine Implement ECM connector and perform a
resistance (Ohm) check of the wires circuit from the Switch Connector to the machine
Implements ECM Connector, correct any problem. Refer to the Table 12 and 13 or the machine
schematic for more information.

4. Replace the Implement ECM.

Note: Failure of the machine Implement ECM is unlikely.

5. For troubleshooting the RH/LH Increment/Decrement Switches on machine equipped with


advanced Joystick, refer to machine schematic.

Table 11

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 11 of 12

Implement ECM 1 (MID 82)


Failure Mode
DTC Description
(FMI)
Left Desired Grade Offset (Increment/Decrement) Switch / Data Erratic
2261 02
Intermittent or incorrect
Right Desired Grade Offset (Increment/Decrement) Switch / Data
2262 02
Erratic Intermittent or incorrect

Code 2261 with FMI 02 is related to the Left Desired Grade Offset (Increment/Decrement) Switch
data.

Code 2262 with FMI 02 is related to the Right Desired Grade Offset (Increment/Decrement) Switch
data.

Note: The System will generate a Level 2 warning when any of the diagnostic codes in the above
table with FMI 02 become active.

• The switch digital Input signal to the Implement ECM is intermittent or missing.

1. Visually perform a check to the machine harness from the switch connector wires to the
implement ECM connector ensure that there is no damages or broken wires, correct any
problem that found.

2. Perform contact connection test of the switch while it is disconnected form the switch. Refer to
the Table 13 or the machine schematic.

3. Perform a resistance check from the switch connector to the Implement ECM connector.

4. Disconnect the sensor connector and the machine Implement ECM connector and perform a
resistance (Ohm) check of the wires circuit from the Switch Connector to the machine
Implements ECM Connector, correct any problem. Refer to the Table 12 and 13 or the machine
schematic for more information.

5. Replace the Switch if it is not working properly.

6. Replace the Implement ECM.

Note: Failure of Implement ECM is highly unlikely.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019
(SEBP4980 - ) - Service Information System Page 12 of 12

Illustration 6 g06076496
RH/LH side offset switch (Increment/Decrement switch)

Table 12
Offset Switch (INC/DEC switch) Implement ECM Connector J2
Pin Function RH Side Switch PIN LH Side Switch PIN
1 INC/DEC signal - INC 46 55
2 Digital return signal (GND) 22 22
3 Pin 3 connected to pin 5
4 Switch neutral signal 45 54
5 Pin 5 connected to pin 3
6 INC/DEC signal - DEC 47 56

To check the switch with an ohm meter, refer to the Table 13 contact connection between the switch
pins.

Disconnect the switch connector form the machine harness and perform the following checks using
an ohm meter.

Table 13
Contact Connection Neutral Increment Position Decrement Position
Between Position (INC) (DEC)
PIN 2 to PIN 1 Open Connected Open
PIN 2 to PIN 3 Connected Open Connected
PIN 2 to PIN 4 Connected Open Open
PIN 2 to PIN 5 Connected Open Connected
PIN 2 to PIN 6 Open Open Connected
PIN 5 to PIN 1 Open Open Open
PIN 5 to PIN 2 Connected Open Connected
PIN 5 to PIN 3 Connected Connected Connected
PIN 5 to PIN 4 Connected Connected Open
PIN 5 to PIN 6 Open Open Connected

Copyright 1993 - 2019 Caterpillar Inc. Thu Nov 14 09:49:56 EST 2019 
All Rights Reserved.
Private Network For SIS Licensees.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 14/11/2019